You are on page 1of 1

600 250

900
shift shift
shift
A5 CC54 CC55

1400 875
1000 CCG39 CCG40 1000 600
PCG1

2850

575
1400
PCG1 PCG1

1575
shift
900 CC2
CC1 PCG1
A4 PCG1 shift CCG1 CCG2

1350
PCG1

shift

shift
625

625
A3
CC3 CC4

shift
900
PCG1 PCG1

shift
175
CCG3 CCG4

3150
300 700
shift shift
A2 CC5 CC6
CCG5 CCG6 700

1350
CC7 shift
A1

1275
CCG5

shift
1275
shift
PCG2 CC8 PCG2
250 CCG7

shift
900
shift

4375
PCG2 PCG2 1200 200

shift
900
DATE Rev PARTICULARS Drwn Check

shift
200
950
V CC12

550
1600 CC11 CCG11
CC9 CC10 CCG10 900 CC13 CC14 REVISIONS :
CCG8 CCG9 LIFT-4 CCG12 CCG13
3500

shift
CC15
CC16 CCG14
U
CCG10 950

shift
CC17

500
100 shift
CCG10 K'
GENERAL NOTES :-
3500

shift 800 100


100
shift shift
shift 1. ALL DIMENSIONS, UNLESS OTHERWISE STATED, ARE IN MILLIMETERS
T

35
CC19 CC20 J'

50
CC18 2. MISSING OR AMBIGUOUS DIMENSIONS IN ANY DRAWING ARE
CCG15 CCG16
3200

CCG15
DC1 I' TO BE CLARIFIED FROM AUTHORITY CONCERNED.

22
DCG1

05
S H' 3. DO NOT SCALE DRAWING, FOLLOW ONLY WRITTEN DIMENSIONS.

18
CC21 CC22 CC23 CC24 CC25 DC2

00
CCG10 CCG17 CCG18 CCG19 CCG16 DCG2
G' 4. PLEASE CHECK THE DIMENSION WITH RESPECT TO ARCHITECTURAL

25
00
F'
PLANS BEFORE EXECUTION.

10
sh
7200

DC3

0
ift
PART-C DC5
DCG3 DC4
DCG1
STRUCTURAL NOTES :-

0
ift

10
1. TYPE OF STRUCTURE :- R.C.C. FRAMED STRUCTURE HAVING

62
DCG4 sh

05
DC6 E' GROUND + 4 FLOORS & ONE FUTURE FLOOR IS CONSIDERED.
R
DCG5 ONE FUTURE FLOOR IS CONSIDERED PART A,B,C & D .
CC26 CC27 CC28 CC29 CC30 DC7 2. DESIGN FORCES :-
CCG10 CCG19 CCG20 CCG17 CCG16 DCG6
3700

41
DC8 DC10 D' DEAD LOADS IS : 875(PART-1)

50
100 100

sh 0
10
DCG7 DCG1

ift
shift

sh 5
shift DC9 LIVE LOADS IS : 875(PART-2)

17
DC11

ift
Q DCG4 DCG8 EARTHQUAKE LOADS IS : 1893-2002,IS:13920-1993 (EQ. ZONE III, R=5, I=1.5)
CC31 CC32

43
CCG21 CCG16 C' 3. SPECIFICATIONS OF P.C.C./R.C.C. WORK SHALL BE AS PER IS : 456-2000.

50
3500

DC12
DC13 DCG3
DCG9 DC14 4. CONCRETE GRADE:- R.C.C M 25, P.C.C (1:4:8) UNLESS SPECIFICALLY STATED.
P DCG8 5. (5.1) CEMENT FOR R.C.C. WORK :- 53 GRADE CEMENT.
DC15

41
sh 5
CC33 CC34 CC35 DCG4 DC18 B'

17

00
DC16

10
sh (5.2) REINFORCEMENT :- HYSD/TMT STEEL (CRS FE-500 GRADE) UPTO PLINTH AS PER IS :1786-2008

ift
CCG10 CCG17 CCG22 DC17

0
DCG10 ift DCG1

sh 0
4000

DCG11

10
(5.3) REINFORCEMENT :- HYSD/TMT STEEL (Fe-500D GRADE) ABOVE PLINTH AS PER IS :1786-2008

ift
5100
DC20 DC19
shift DCG12 6. ALL COLUMN SIZE REDUCTION SHALL BE DONE BY EQUALLY

35
DCG13 A'

50
O CC38 DC24 DC21 ON BOTH SIDE HENCE CENTER LINE OF BOTH UPPER & LOWER
CCG10 DC22
CC36 CC37 DC23 DCG13 DCG14 DCG5 COLUMN SHOULD BE THE SAME.

shift
100
CCG23 CCG24 DCG13 DC25 5
DC26
PART-D 17
3700

400 DCG8 7. MORTAR PROPORTION IN AERATED LIGHT WEIGHT CONCRETE BLOCK : 1:5 CEMENT MORTAR.
shift

75 DCG15
250

ift
150 400 DC33 DC28

sh

15 ift
shift

shift
250

CC41 shift 250 shift 8. CLEAR COVER TO REINFORCEMENT :

0
shift CC43 DCG1

sh
CCG27 shift DCG17 5 DC27
N CC42 CCG28 DC30 DC31 7 DC29 DCG3 FOOTING : 60 mm COLUMN : SIDE UP TO 200 = 30 mm
CC39

ift
CCG10 75 CC44 DCG13 DCG13 DCG16 DC32

sh
CCG25 CC40 SLABS : 25 mm

sh 0
CCG29 DC34 SIDE ABOVE 200 = 40 mm.

10
CCG26 100 LIFT-3 100 shift 5150 DCG8

ift
75 DCG15 DC35 BEAMS : 30 mm
3850

50
shift shift DCG2 1'

28
100 DC36 CLEAR COVER SHALL BE MEASURED FROM STIRRUPS.

5
ift

sh 5
1350

17
sh 0
7
DCG14

10
sh

ift
CC45 CC46 shift DC37

ift
M CCG30 CCG31 DC39 DC40 DC38 9. ORIENTATION OF COLUMN SHALL BE STRICTLY FOLLOWED AS SHOWN IN THE PLAN.
150 CC47 CC48 DCG4 DCG6 2'
DCG18
shift

59 ift
DCG13
50

shift CCG33 10. IN COLUMNS NOT MORE THAN 50% BARS SHALL BE SPLICED AT A SECTION.

0
150 150 CCG32

sh
3300

00
DC45 DC41

sh 0
75 DC42

66
CC53

10
CC49 shift shift CC52 DCG4 DC44 11. ALL COLUMNS REINFORCEMENTS SHALL BE WITH STAGGERED LAP JOINT.

ift
DCG19 DC43
ift

CCG38 DCG14
shift

shift

CCG37 DCG4
250

250

CCG34 CC50 CC51


sh

CCG35 CCG36 DC48 DCG4


L 42 DC46 12. STRIPPING TIME OF FORM WORK FOR RCC- AS DECIDED BY SITE
800

DCG21 0 DCG15
ENGINEER IN ACCORDANCE WITH IS-456/2000.

sh
AC5
shift

shift
200

200

ift
DC47
75

K AC1 AC3 AC4 ift DC49 3'


AC2 ACG4 ACG5 sh DCG20 DCG9
ACG1 DC50 13. STRUCTURAL ENGINEER & ARCHITECT IS NOT RESPONSIBLE FOR
3600

ACG3

39 ift
ACG2 DCG4

00
5
75 100 DC51

sh
59 ift
CENTERING,SHUTTERING, QUALITY OF CONSTRUCTION MATERIAL

sh 0

69
25
shift
250

10
0
sh DCG15

26
shift shift

ift
DC53 DC52 AND WRONG INTERPRETATION OF DRG.

16 hift
J DCG4

20
DCG4

sh 0
s
AC7

10
14.CONTRACTOR SHALL BE FULLY RESPONSIBLE

ift
AC6 ACG6 AC8 AC9 42 DC54
ACG3 ACG7 ACG3 0 DCG22 DC55 FOR ALL EXECUTION WORK AT SITE.
LIFT-5 DCG13
4650

11
sh 20 4'
DC56 tif DC57 15. THE EXCAVATED AREA OF PLINTH/FOUNDATION TO BE REFILLED WITH

00
sh
DCG23

27
25

60
ift
DCG24

05
MURRUM/GOOD EARTH OR AS DIRECTED BY EIC.
18
DC58
I DCG4 16. COMPACT THE MURRUM TO GIVE A FIELD DENSITY OF 60-62 KG/CFT (2.3GM/CC),

16 hift
shift

shift

shift

AC10 AC11
400

400

400

20
ACG8 ACG9 AC12 AC13 AC14 s 17. MINIMUM SAFE BEARING CAPACITY OF SOIL FOR FOUNDATION MUST BE
ACG10 ACG3 ACG3 DC59 5'
DCG25 150 KN/SQM.(15.0 TON/SQM). AT 2.5 M. DEPTH FROM LOWEST EX.G.L. OR UP TO HARD STRATA.

75
11 18. DEVELOPMENT LENGTH ( Ld ) OF BAR FOR SPLICING SHALL BE ASPER

61
6850

20
LAP LENGTH SCHEDULE OF BAR.
sh
DC60 ift 19. R.C.C. BAND SHOULD BE PROVIDED AT WINDOW SILL LEVEL.
DCG26 DC61 DC62
DCG13 DCG13 20. CHICKEN WIRE MESH SHOULD BE PROVIDED AT ALL THE JUNCTION OF

25
6'

39
H R.C.C. AND BRICK WORK.
AC15 AC16 AC17 AC18 AC19 6270 21. ABOVE ROOF LEVEL COLUMN FOR FUTURE EXPANSION SHALL BE
ACG2 ACG11 ACG12 ACG3 ACG3
7' CONSTRUCT UP TO 1200MM HEIGHT.

25
DC63

39
DCG13
7100

8'
DC64
AS-BUILT DRAWINGS
3500

DCG13

G
AC20 AC21 AC22 AC23 AC24 DC66
2750

ACG8 ACG3 ACG3 ACG13 ACG14 400 DC65


DCG13 DCG13 CLIENT :-
shift
F MEDICAL EDUCATION DEPARTMENT GOVERNMENT
850

AC31
ACG16
BC1
E AC25
ACG2
AC26
ACG3
AC27
ACG3
AC28
ACG3
AC29
ACG8
AC30
ACG15 BCG1 BC2
BCG2
BC3
BCG3
BC4
BCG4
BC5
BCG5
BC6
BCG1 OF RAJASTHAN
7200

PART-A PROJECT MANAGEMENT CONSULTANT :-


550
shift

D AC36
AC38
ACG20 NATIONAL BUILDINGS CONSTRUCTION
AC32 AC33 AC34 AC35 ACG18 AC37 AC39 BC7 BC8 BC9 BC10 BC11 BC12
ACG2 ACG9 ACG17 ACG9 ACG19 ACG21 BCG1 BCG6 BCG6 BCG7 BCG8 BCG1 CORPORATION LIMITED
4000

AC41 PART-B
7000

ACG23
AC40
ACG22 ASSOCIATE CONSULTANT :-
2700 750 400 AKA CONSULTANTS (INDIA) PVT. LTD.
2800

AC43 AC48 shift


AC42 ACG25 ACG3 LIFT-2
C AC44 AC49 AC50 BC13
ACG24 LIFT-1 ACG8 ACG27 ACG28 BCG9 PROJECT :-
AC45 AC46 AC47 AC51 BC14 BC15 BC16 BC17 BC18
ACG29 SCALE MEDICAL COLLEGE CAMPUS FOR 100 MBBS ADMISSIONS
2600 700 ACG3 ACG3 ACG26 BCG10 BCG11 BCG12 BCG11 BCG13
1175
3800

shift

1:200
AC61
BC19 ANNUALLY & UP GRADATION OF GOVT. DIST. HOSPITAL
BCG14
AC53 AC54 AC55 ACG34 INTO TEACHING HOSPITAL, DUNGARPUR,RAJASTHAN.
B ACG31 ACG32 ACG8
AC52 AC56 AC57 AC58 AC59 AC60 BC20 BC21 BC22 BC23 BC24 BC25
2350
shift

ACG30 ACG10 ACG3 ACG10 ACG3 ACG33 BCG15 BCG16 BCG12 BCG12 BCG12 BCG13
AC62
COLLEGE BLOCK
7000

ACG35

TITLE :-
SIZE COLUMN CENTER LINE PLAN
A
A1
AC63 AC64 AC65 AC66 AC67 AC68 AC69 BC26 BC27 BC28 BC29 BC30 BC31 BC32
ACG36 ACG8 ACG2 ACG3 ACG2 ACG37 ACG38 BCG17 BCG18 BCG19 BCG20 BCG21 BCG4 BCG22 DATE : - 04.05.2020 DRWN BY :- V.S. CHKD BY :- S.G.
750 3200 4000 2350 850 3600 3600 3200 4000 3200 2650 1500 2700 3350 3850 3600 3600 7200 7600 6800
3350 2700 3700
400 650 NORTH

26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
N
W NW
N

NE
THIS DRAWING IS COPYRIGHT OF-

W
SW

E
NATIONAL BUILDINGS CONSTRUCTION CORPORATION S
SE
E
LIMITED (NBCC), AND IS NOT TO BE REPRODUCED, STRUCTURE ENGINEER ARCHITECT
COLUMN CENTER LINE LAYOUT HANDED OVER TO OTHER PERSON OR USED FOR ANY
S

PURPOSE OTHER THAN THAT FOR WHICH IT HAS BEEN


ISSUED. OTHERWISE IT SHALL BE COPYRIGHT VIOLATION.
NBCC DRG. NO. : - 621 - MC - E - S - 2000 SHEET NO. : - 1 OF 1