BEAM DESIGN
DIMENSIONS
FRAME DIAMETER BEAM Mu Mumax
BASE DEPTH E.D
1-2 64756000 153996377.5
FRAME A 20 250 450 375 2-3 46536000 153996377.5
3-4 48024000 153996377.5
1-2 94256000 153996377.5
FRAME B 20 250 450 375 2-3 63164000 153996377.5
3-4 66008000 153996377.5
1-2 85496000 153996377.5
FRAME C 20 250 450 375 2-3 62876000 153996377.5
3-4 65684000 153996377.5
1-2 85496000 153996377.5
FRAME D 20 250 450 375 2-3 62876000 153996377.5
3-4 65684000 153996377.5
1-2 94256000 153996377.5
FRAME E 20 250 450 375 2-3 63164000 153996377.5
3-4 66008000 153996377.5
1-2 64756000 153996377.5
FRAME F 20 250 450 375 2-3 46536000 153996377.5
3-4 48024000 153996377.5
DIMENSIONS
FRAME DIAMETER BEAM Mu Mumax
BASE DEPTH E.D
1-2 19764000 153996377.5
FRAME A 20 250 450 375 2-3 9900000 153996377.5
3-4 10056000 153996377.5
1-2 19296000 153996377.5
FRAME B 20 250 450 375 2-3 3768000 153996377.5
3-4 3420000 153996377.5
1-2 3588000 153996377.5
FRAME C 20 250 450 375 2-3 3840000 153996377.5
3-4 3588000 153996377.5
1-2 3588000 153996377.5
FRAME D 20 250 450 375 2-3 3840000 153996377.5
3-4 3588000 153996377.5
1-2 19296000 153996377.5
FRAME E 20 250 450 375 2-3 3768000 153996377.5
3-4 3420000 153996377.5
1-2 19764000 153996377.5
FRAME F 20 250 450 375 2-3 9900000 153996377.5
3-4 10056000 153996377.5
DIMENSIONS
FRAME DIAMETER BEAM Mu Mumax
BASE DEPTH E.D
1-2 56076000 153996377.5
FRAME A 20 250 450 375 2-3 46092000 153996377.5
3-4 56740000 153996377.5
1-2 74456000 153996377.5
FRAME B 20 250 450 375 2-3 62732000 153996377.5
3-4 85496000 153996377.5
1-2 65684000 153996377.5
FRAME C 20 250 450 375 2-3 62876000 153996377.5
3-4 85496000 153996377.5
1-2 65684000 153996377.5
FRAME D 20 250 450 375 2-3 62876000 153996377.5
3-4 85496000 153996377.5
1-2 74456000 153996377.5
FRAME E 20 250 450 375 2-3 62732000 153996377.5
3-4 85496000 153996377.5
1-2 56076000 153996377.5
FRAME F 20 250 450 375 2-3 46092000 153996377.5
3-4 56740000 153996377.5
FRAME A
WIND LOAD LC1 LC2
L M R L M R L M R
24.13 0.00 -18.27 -26.15 19.76 -26.84 12.46 19.76 -56.08
17.31 0.00 -17.31 -18.84 9.90 -18.40 8.86 9.90 -46.09
18.27 0.00 -24.13 -18.79 10.06 -18.13 10.44 10.06 -56.74
FRAME B
WIND LOAD LC1 LC2
L M R L M R L M R
48.26 0.00 -36.53 -17.04 19.30 -16.01 60.18 19.30 -74.46
34.61 0.00 -34.61 -7.79 3.77 -7.36 47.59 3.77 -62.73
36.53 0.00 -48.26 -7.56 3.42 -8.28 50.89 3.42 -85.50
FRAME C
WIND LOAD LC1 LC2
L M R L M R L M R
48.26 0.00 -36.53 -8.28 3.59 -7.24 68.94 3.59 -65.68
34.61 0.00 -34.61 -7.50 3.84 -7.50 47.88 3.84 -62.88
36.53 0.00 -48.26 -7.24 3.59 -8.28 51.21 3.59 -85.50
FRAME D
WIND LOAD LC1 LC2
L M R L M R L M R
48.26 0.00 -36.53 -8.28 3.59 -7.24 68.94 3.59 -65.68
34.61 0.00 -34.61 -7.50 3.84 -7.50 47.88 3.84 -62.88
36.53 0.00 -48.26 -7.24 3.59 -8.28 51.21 3.59 -85.50
FRAME E
WIND LOAD LC1 LC2
L M R L M R L M R
48.26 0.00 -36.53 -17.04 19.30 -16.01 60.18 19.30 -74.46
34.61 0.00 -34.61 -7.79 3.77 -7.36 47.59 3.77 -62.73
36.53 0.00 -48.26 -7.56 3.42 -8.28 50.89 3.42 -85.50
FRAME F
WIND LOAD LC1 LC2
L M R L M R L M R
24.13 0.00 -18.27 -26.15 19.76 -29.23 12.46 19.76 -56.08
17.31 0.00 -17.31 -18.84 9.90 -27.70 8.86 9.90 -46.09
18.27 0.00 -24.13 -18.79 10.06 -38.61 10.44 10.06 -56.74
Spacing of Bars
No. of Bars Spacing Checking No of bars to use
(milimeters)
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
3 45.00 OK! 3 45.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
3 45.00 OK! 3 45.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
3 45.00 OK! 3 45.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
3 45.00 OK! 3 45.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
Spacing of Bars
No. of Bars Spacing Checking No of bars to use
(milimeters)
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
Spacing of Bars
No. of Bars Spacing Checking No of bars to use
(milimeters)
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
3 45.00 OK! 3 45.00
2 110.00 OK! 2 110.00
3 45.00 OK! 3 45.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
3 45.00 OK! 3 45.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
3 45.00 OK! 3 45.00
3 45.00 OK! 3 45.00
2 110.00 OK! 2 110.00
3 45.00 OK! 3 45.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
2 110.00 OK! 2 110.00
SECOND FLOOR
BEAM DESIGN
DIMENSIONS
FRAME DIAMETER BEAM Mu Mumax
BASE DEPTH E.D
1-2 164020000 410657006.8
FRAME A 20 375 575 500 2-3 134496000 410657006.8
3-4 137518000 410657006.8
1-2 236216000 410657006.8
FRAME B 20 375 575 500 2-3 212732000 410657006.8
3-4 187666000 410657006.8
1-2 88682000 410657006.8
FRAME C 20 375 575 500 2-3 72848000 410657006.8
3-4 77842000 410657006.8
1-2 88682000 410657006.8
FRAME D 20 375 575 500 2-3 72848000 410657006.8
3-4 77842000 410657006.8
1-2 252596000 410657006.8
FRAME E 20 375 575 500 2-3 198622000 410657006.8
3-4 185446000 410657006.8
1-2 204484000 410657006.8
FRAME F 20 375 575 500 2-3 167280000 410657006.8
3-4 172478000 410657006.8
DIMENSIONS
FRAME DIAMETER BEAM Mu Mumax
BASE DEPTH E.D
1-2 112156000 276919708.2
FRAME A 20 350 500 425 2-3 56816000 276919708.2
3-4 26272000 276919708.2
1-2 134052000 276919708.2
FRAME B 20 350 500 425 2-3 88952000 276919708.2
3-4 64224000 276919708.2
1-2 75696000 276919708.2
FRAME C 20 350 500 425 2-3 90748000 276919708.2
3-4 130368000 276919708.2
1-2 75696000 276919708.2
FRAME D 20 350 500 425 2-3 90748000 276919708.2
3-4 130368000 276919708.2
1-2 148804000 276919708.2
FRAME E 20 350 500 425 2-3 73560000 276919708.2
3-4 64336000 276919708.2
1-2 112156000 276919708.2
FRAME F 20 350 500 425 2-3 23086000 276919708.2
3-4 26272000 276919708.2
S
DIMENSIONS
FRAME DIAMETER BEAM Mu Mumax
BASE DEPTH E.D
1-2 91300000 276919708.2
FRAME A 20 350 500 425 2-3 77390000 276919708.2
3-4 80046000 276919708.2
1-2 133654000 276919708.2
FRAME B 20 350 500 425 2-3 100370000 276919708.2
3-4 144128000 276919708.2
1-2 76572000 276919708.2
FRAME C 20 350 500 425 2-3 73258000 276919708.2
3-4 89892000 276919708.2
1-2 76572000 276919708.2
FRAME D 20 350 500 425 2-3 73258000 276919708.2
3-4 89892000 276919708.2
1-2 119394000 276919708.2
FRAME E 20 350 500 425 2-3 117080000 276919708.2
3-4 142238000 276919708.2
1-2 126260000 276919708.2
FRAME F 20 350 500 425 2-3 108174000 276919708.2
3-4 120510000 276919708.2
FRAME A
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
25.28 0.00 -21.86 -145.26 112.16 -32.43 -83.12 106.59 -91.30 -164.02
20.49 0.00 -20.49 -119.06 56.82 -29.26 -68.93 48.60 -77.39 -134.50
21.86 0.00 -25.28 -119.96 19.78 -24.27 -67.57 26.27 -80.05 -137.52
FRAME B
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
50.57 0.00 -43.71 -184.03 134.05 -30.71 -74.39 124.69 -133.65 -236.22
40.98 0.00 -40.98 -181.02 88.95 -3.12 -81.60 71.93 -100.37 -212.73
43.71 0.00 -50.57 -133.25 64.22 -52.56 -47.79 57.53 -144.13 -187.67
FRAME C
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
50.57 0.00 -43.71 -7.46 75.70 -6.28 73.14 66.93 -76.57 -88.68
40.98 0.00 -40.98 -7.15 90.75 -7.80 58.29 73.26 -73.26 -72.85
43.71 0.00 -50.57 -8.31 130.37 -9.40 62.03 96.58 -89.89 -77.84
FRAME D
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
50.57 0.00 -43.71 -7.46 75.70 -6.28 73.14 66.93 -76.57 -88.68
40.98 0.00 -40.98 -7.15 90.75 -7.80 58.29 73.26 -73.26 -72.85
43.71 0.00 -50.57 -8.31 130.37 -9.40 62.03 96.58 -89.89 -77.84
FRAME E
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
50.57 0.00 -43.71 -210.24 148.80 -7.90 -90.77 133.91 -119.39 -252.60
40.98 0.00 -40.98 -158.44 73.56 -29.85 -67.49 62.31 -117.08 -198.62
43.71 0.00 -50.57 -129.70 64.34 -49.54 -45.57 57.60 -142.24 -185.45
FRAME F
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
50.57 0.00 -43.71 -145.26 112.16 -32.43 -42.66 106.59 -126.26 -204.48
40.98 0.00 -40.98 -119.06 16.00 -26.06 -36.14 23.09 -108.17 -167.28
43.71 0.00 -50.57 -119.96 19.78 -24.27 -32.61 26.27 -120.51 -172.48
BEAM DESIGN
DIMENSIONS
FRAME DIAMETER BEAM Mu Mumax
BASE DEPTH E.D
1-2 152886000 345910085.4
FRAME A 20 350 550 475 2-3 123464000 345910085.4
3-4 136446000 345910085.4
1-2 214906000 345910085.4
FRAME B 20 350 550 475 2-3 190632000 345910085.4
3-4 160626000 345910085.4
1-2 117356000 345910085.4
FRAME C 20 350 550 475 2-3 79276000 345910085.4
3-4 113456000 345910085.4
1-2 117356000 345910085.4
FRAME D 20 350 550 475 2-3 79276000 345910085.4
3-4 113456000 345910085.4
1-2 215046000 345910085.4
FRAME E 20 350 550 475 2-3 189952000 345910085.4
3-4 163186000 345910085.4
1-2 152886000 345910085.4
FRAME F 20 350 550 475 2-3 123464000 345910085.4
3-4 136446000 345910085.4
DIMENSIONS
FRAME DIAMETER BEAM Mu Mumax
BASE DEPTH E.D
1-2 110688000 345910085.4
FRAME A 20 350 550 475 2-3 56868000 345910085.4
3-4 20626000 345910085.4
1-2 130868000 345910085.4
FRAME B
FRAME B 20 350 550 475 2-3 89128000 345910085.4
3-4 101456000 345910085.4
1-2 63604000 345910085.4
FRAME C 20 350 550 475 2-3 90604000 345910085.4
3-4 144260000 345910085.4
1-2 63604000 345910085.4
FRAME D 20 350 550 475 2-3 90604000 345910085.4
3-4 144260000 345910085.4
1-2 130500000 345910085.4
FRAME E 20 350 550 475 2-3 89512000 345910085.4
3-4 62992000 345910085.4
1-2 110688000 345910085.4
FRAME F 20 350 550 475 2-3 56868000 345910085.4
3-4 20626000 345910085.4
DIMENSIONS
FRAME DIAMETER BEAM Mu Mumax
BASE DEPTH E.D
1-2 79892000 345910085.4
FRAME A 20 350 550 475 2-3 65228000 345910085.4
3-4 67626000 345910085.4
1-2 110842000 345910085.4
FRAME B 20 350 550 475 2-3 78886000 345910085.4
3-4 158962000 345910085.4
1-2 164956000 345910085.4
FRAME C 20 350 550 475 2-3 187136000 345910085.4
3-4 153866000 345910085.4
1-2 164956000 345910085.4
FRAME D 20 350 550 475 2-3 187136000 345910085.4
3-4 153866000 345910085.4
1-2 110332000 345910085.4
FRAME E 20 350 550 475 2-3 78686000 345910085.4
3-4 120102000 345910085.4
1-2 79892000 345910085.4
FRAME F 20 350 550 475 2-3 65228000 345910085.4
3-4 67626000 345910085.4
FRAME A
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
17.26 0.00 -14.84 -147.33 110.69 -32.35 -97.65 105.38 -79.89 -152.89
13.92 0.00 -13.92 -118.41 56.87 -26.37 -78.92 48.61 -65.23 -123.46
14.84 0.00 -17.26 -129.99 14.04 -24.38 -88.96 20.63 -67.63 -136.45
FRAME B
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
34.51 0.00 -29.69 -188.98 130.87 -30.68 -104.47 121.84 -110.84 -214.91
27.83 0.00 27.83 -179.86 89.13 -2.38 -101.58 72.20 10.17 -190.63
29.69 0.00 34.51 -126.56 101.46 -115.68 -65.62 80.46 -48.53 -160.63
FRAME C
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
34.51 0.00 -29.69 -50.86 63.60 -132.76 -6.92 57.14 -164.96 -117.36
27.83 0.00 27.83 -2.43 90.60 -175.01 9.78 73.17 -98.08 -79.28
29.69 0.00 34.51 -50.36 144.26 -109.28 -18.45 107.55 -43.43 -113.46
FRAME D
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
34.51 0.00 -29.69 -50.86 63.60 -132.76 -6.92 57.14 -164.96 -117.36
27.83 0.00 27.83 -2.43 90.60 -175.01 9.78 73.17 -98.08 -79.28
29.69 0.00 34.51 -50.36 144.26 -109.28 -18.45 107.55 -43.43 -113.46
FRAME E
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
34.51 0.00 -29.69 -189.20 130.50 -29.86 -104.61 121.61 -110.33 -215.05
27.83 0.00 27.83 -178.77 89.51 -2.06 -100.90 72.44 10.37 -189.95
29.69 0.00 34.51 -130.65 62.99 -53.50 -68.18 56.42 -9.67 -163.19
FRAME F
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
17.26 0.00 -14.84 -147.33 110.69 -32.35 -97.65 105.38 -79.89 -152.89
13.92 0.00 -13.92 -118.41 56.87 -26.37 -78.92 48.61 -65.23 -123.46
14.84 0.00 -17.26 -129.99 14.04 -24.38 -88.96 20.63 -67.63 -136.45
BEAM DESIGN
FOU
DIMENSIONS
FRAME DIAMETER BEAM Mu Mumax DESIGN
BASE DEPTH E.D
1-2 149912000 345910085.4 SINGLY
FRAME A 20 350 550 475 2-3 117656000 345910085.4 SINGLY
3-4 118564000 345910085.4 SINGLY
1-2 191008000 345910085.4 SINGLY
FRAME B 20 350 550 475 2-3 179636000 345910085.4 SINGLY
3-4 118090000 345910085.4 SINGLY
1-2 90854000 345910085.4 SINGLY
FRAME C 20 350 550 475 2-3 57180000 345910085.4 SINGLY
3-4 89430000 345910085.4 SINGLY
1-2 90854000 345910085.4 SINGLY
FRAME D 20 350 550 475 2-3 57180000 345910085.4 SINGLY
3-4 89430000 345910085.4 SINGLY
1-2 190912000 345910085.4 SINGLY
FRAME E 20 350 550 475 2-3 180036000 345910085.4 SINGLY
3-4 117530000 345910085.4 SINGLY
1-2 133912000 345910085.4 SINGLY
FRAME F 20 350 550 475 2-3 117656000 345910085.4 SINGLY
3-4 118852000 345910085.4 SINGLY
F
DIMENSIONS
FRAME DIAMETER BEAM Mu Mumax DESIGN
BASE DEPTH E.D
1-2 108832000 345910085.4 SINGLY
FRAME A 20 350 550 475 2-3 57440000 345910085.4 SINGLY
3-4 25276000 345910085.4 SINGLY
1-2 129444000 345910085.4 SINGLY
FRAME B 20 350 550 475 2-3 89752000 345910085.4 SINGLY
3-4 62048000 345910085.4 SINGLY
1-2 61452000 345910085.4 SINGLY
FRAME C 20 350 550 475 2-3 91232000 345910085.4 SINGLY
3-4 62012000 345910085.4 SINGLY
1-2 61452000 345910085.4 SINGLY
FRAME D 20 350 550 475 2-3 91232000 345910085.4 SINGLY
3-4 62012000 345910085.4 SINGLY
1-2 129556000 345910085.4 SINGLY
FRAME E 20 350 550 475 2-3 89704000 345910085.4 SINGLY
3-4 61520000 345910085.4 SINGLY
1-2 108832000 345910085.4 SINGLY
FRAME F 20 350 550 475 2-3 57440000 345910085.4 SINGLY
3-4 25486000 345910085.4 SINGLY
FOU
DIMENSIONS
FRAME DIAMETER BEAM Mu Mumax DESIGN
BASE DEPTH E.D
1-2 67946000 345910085.4 SINGLY
FRAME A 20 350 550 475 2-3 53794000 345910085.4 SINGLY
3-4 54576000 345910085.4 SINGLY
1-2 87476000 345910085.4 SINGLY
FRAME B 20 350 550 475 2-3 57478000 345910085.4 SINGLY
3-4 91956000 345910085.4 SINGLY
1-2 139330000 345910085.4 SINGLY
FRAME C 20 350 550 475 2-3 174380000 345910085.4 SINGLY
3-4 131844000 345910085.4 SINGLY
1-2 139330000 345910085.4 SINGLY
FRAME D 20 350 550 475 2-3 174380000 345910085.4 SINGLY
3-4 131844000 345910085.4 SINGLY
1-2 87586000 345910085.4 SINGLY
FRAME E 20 350 550 475 2-3 57578000 345910085.4 SINGLY
3-4 90786000 345910085.4 SINGLY
1-2 67946000 345910085.4 SINGLY
FRAME F 20 350 550 475 2-3 53794000 345910085.4 SINGLY
3-4 55126000 345910085.4 SINGLY
FRAME A
WIND LOAD LC1 LC2 LC3
M R L M R L M R L M
0.00 -7.46 -149.91 108.83 -32.30 -113.37 103.82 -67.95 -141.47 103.82
0.00 -7.00 -117.66 57.44 -26.02 -89.36 49.11 -53.79 -111.76 49.11
0.00 -8.78 -118.56 18.57 -24.57 -89.45 25.28 -54.58 -113.32 25.28
FRAME B
WIND LOAD LC1 LC2 LC3
M R L M R L M R L M
0.00 -14.93 -191.01 129.44 -31.08 -132.88 120.95 -87.48 -189.04 120.95
0.00 -14.00 -179.64 89.75 -3.54 -123.56 72.59 -57.48 -168.36 72.59
0.00 -17.55 -109.24 62.05 -51.89 -70.31 55.83 -91.96 -118.09 55.83
FRAME C
WIND LOAD LC1 LC2 LC3
M R L M R L M R L M
0.00 -14.93 -50.13 61.45 -130.27 -34.69 55.46 -139.33 -90.85 55.46
0.00 -14.00 -2.62 91.23 -174.38 -12.38 73.65 -164.53 -57.18 73.65
0.00 -17.55 -50.43 62.01 -115.72 -41.65 55.81 -131.84 -89.43 55.81
FRAME D
WIND LOAD LC1 LC2 LC3
M R L M R L M R L M
0.00 -14.93 -50.13 61.45 -130.27 -34.69 55.46 -139.33 -90.85 55.46
0.00 -14.00 -2.62 91.23 -174.38 -12.38 73.65 -164.53 -57.18 73.65
0.00 -17.55 -50.43 62.01 -115.72 -41.65 55.81 -131.84 -89.43 55.81
FRAME E
WIND LOAD LC1 LC2 LC3
M R L M R L M R L M
0.00 -14.93 -190.91 129.56 -31.26 -132.82 121.02 -87.59 -188.98 121.02
0.00 -14.00 -180.04 89.70 -3.70 -123.81 72.56 -57.58 -168.61 72.56
0.00 -17.55 -108.35 61.52 -50.02 -69.75 55.50 -90.79 -117.53 55.50
FRAME F
WIND LOAD LC1 LC2 LC3
M R L M R L M R L M
0.00 -7.46 -133.91 108.83 -32.30 -103.37 103.82 -67.95 -131.47 103.82
0.00 -7.00 -117.66 57.44 -26.02 -89.36 49.11 -53.79 -111.76 49.11
0.00 -8.78 -118.85 18.90 -25.45 -89.63 25.49 -55.13 -113.50 25.49
Spacing of Bars
Checking No of bars to use
(milimeters)
OK! 4 56.67
OK! 3 95.00
OK! 3 95.00
OK! 5 37.50
OK! 5 37.50
OK! 3 95.00
OK! 3 95.00
OK! 2 210.00
OK! 3 95.00
OK! 3 95.00
OK! 2 210.00
OK! 3 95.00
OK! 5 37.50
OK! 5 37.50
OK! 3 95.00
OK! 4 56.67
OK! 3 95.00
OK! 3 95.00
Spacing of Bars
Checking No of bars to use
(milimeters)
OK! 3 95.00
OK! 2 210.00
OK! 2 210.00
OK! 3 95.00
OK! 3 95.00
OK! 2 210.00
OK! 2 210.00
OK! 3 95.00
OK! 2 210.00
OK! 2 210.00
OK! 3 95.00
OK! 2 210.00
OK! 3 95.00
OK! 3 95.00
OK! 2 210.00
OK! 3 95.00
OK! 2 210.00
OK! 2 210.00
Spacing of Bars
Checking No of bars to use
(milimeters)
OK! 2 210.00
OK! 2 210.00
OK! 2 210.00
OK! 2 210.00
OK! 2 210.00
OK! 3 95.00
OK! 4 56.67
OK! 5 37.50
OK! 4 56.67
OK! 4 56.67
OK! 5 37.50
OK! 4 56.67
OK! 2 210.00
OK! 2 210.00
OK! 3 95.00
OK! 2 210.00
OK! 2 210.00
OK! 2 210.00
ROOF DECK
BEAM DESIGN
R
DIMENSIONS
FRAME DIAMETER BEAM Mu Mumax
BASE DEPTH E.D
1-2 124836000 345910085.4
FRAME A 20 350 550 475 2-3 112148000 345910085.4
3-4 112668000 345910085.4
1-2 169308000 345910085.4
FRAME B 20 350 550 475 2-3 173028000 345910085.4
3-4 177928000 345910085.4
1-2 30426000 345910085.4
FRAME C 20 350 550 475 2-3 30276000 345910085.4
3-4 33646000 345910085.4
1-2 30426000 345910085.4
FRAME D 20 350 550 475 2-3 30276000 345910085.4
3-4 33646000 345910085.4
1-2 169356000 345910085.4
FRAME E 20 350 550 475 2-3 172932000 345910085.4
3-4 178184000 345910085.4
1-2 124836000 345910085.4
FRAME F 20 350 550 475 2-3 112148000 345910085.4
3-4 112668000 345910085.4
DIMENSIONS
FRAME DIAMETER BEAM Mu Mumax
BASE DEPTH E.D
1-2 122888000 345910085.4
FRAME A 20 350 550 475 2-3 51272000 345910085.4
3-4 57968000 345910085.4
1-2 134584000 345910085.4
FRAME B 20 350 550 475 2-3 81820000 345910085.4
3-4 92536000 345910085.4
1-2 92780000 345910085.4
FRAME C 20 350 550 475 2-3 82424000 345910085.4
3-4 92524000 345910085.4
1-2 92780000 345910085.4
FRAME D 20 350 550 475 2-3 82424000 345910085.4
3-4 92524000 345910085.4
1-2 134552000 345910085.4
FRAME E 20 350 550 475 2-3 81836000 345910085.4
3-4 92776000 345910085.4
1-2 106888000 345910085.4
FRAME F 20 350 550 475 2-3 51272000 345910085.4
3-4 57968000 345910085.4
R
DIMENSIONS
FRAME DIAMETER BEAM Mu Mumax
BASE DEPTH E.D
1-2 49492000 345910085.4
FRAME A 20 350 550 475 2-3 37144000 345910085.4
3-4 33920000 345910085.4
1-2 54084000 345910085.4
FRAME B 20 350 550 475 2-3 28660000 345910085.4
3-4 30134000 345910085.4
1-2 178248000 345910085.4
FRAME C 20 350 550 475 2-3 170544000 345910085.4
3-4 23386000 345910085.4
1-2 178248000 345910085.4
FRAME D 20 350 550 475 2-3 170544000 345910085.4
3-4 23386000 345910085.4
1-2 54054000 345910085.4
FRAME E 20 350 550 475 2-3 28610000 345910085.4
3-4 30564000 345910085.4
1-2 49492000 345910085.4
FRAME F 20 350 550 475 2-3 37144000 345910085.4
3-4 33920000 345910085.4
FRAME A
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
2.57 0.00 -2.08 -124.84 122.89 -22.73 -100.92 110.47 -49.49 -109.15
1.87 0.00 -1.87 -112.15 51.27 -17.84 -91.61 43.30 -37.14 -97.60
2.08 0.00 -2.57 -112.67 57.97 -15.62 -91.77 48.92 -33.92 -98.43
FRAME B
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
5.13 0.00 -4.16 -169.31 134.58 -11.09 -131.71 121.76 -54.08 -148.12
3.74 0.00 3.74 -173.03 81.82 11.19 -133.64 65.67 -16.69 -145.60
4.16 0.00 -5.13 -177.93 92.54 6.16 -136.36 74.19 -30.13 -149.68
FRAME C
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
5.13 0.00 -4.16 5.63 92.78 -178.25 -14.01 74.32 -149.97 -30.43
3.74 0.00 3.74 9.49 82.42 -170.54 -18.31 66.39 -130.83 -30.28
4.16 0.00 -5.13 7.86 92.52 16.89 -20.33 74.16 -23.39 -33.65
FRAME D
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
5.13 0.00 -4.16 5.63 92.78 -178.25 -14.01 74.32 -149.97 -30.43
3.74 0.00 3.74 9.49 82.42 -170.54 -18.31 66.39 -130.83 -30.28
4.16 0.00 -5.13 7.86 92.52 16.89 -20.33 74.16 -23.39 -33.65
FRAME E
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
5.13 0.00 -4.16 -169.36 134.55 -11.04 -131.74 121.74 -54.05 -148.15
3.74 0.00 3.74 -172.93 81.84 11.27 -133.58 65.68 -16.64 -145.54
4.16 0.00 -5.13 -178.18 92.78 5.47 -136.52 74.34 -30.56 -149.84
FRAME F
WIND LOAD LC1 LC2 LC3
L M R L M R L M R L
2.57 0.00 -2.08 -124.84 106.89 -22.73 -100.92 100.47 -49.49 -109.15
1.87 0.00 -1.87 -112.15 51.27 -17.84 -91.61 43.30 -37.14 -97.60
2.08 0.00 -2.57 -112.67 57.97 -15.62 -91.77 48.92 -33.92 -98.43
As
75
350
𝐼𝐹 𝑀𝑢>Ø𝑀𝑡𝑛 ∴ 𝑇𝑅𝐴𝑁𝑆𝐼𝑇𝐼𝑂𝑁
𝐼𝐹 Ø𝑀𝑡𝑛 >𝑀𝑢𝑇𝐸𝑁𝑆𝐼𝑂𝑁
∴
Ø=0.9
𝑅𝑛= 149912000/((0.9)(350)(475)^2 )
𝑘𝑁 𝑚
= 2.10930132348415
𝜌 =(0.85(21))/345 [1−√(1−(2(2.109301323))/((0.85)(21)))] =
0.006525414237828
𝑆𝑝𝑎𝑐𝑖𝑛𝑔= (350−100−4(20))/(4−1)=
56.67
𝐼𝐹 𝑀𝑢>Ø𝑀𝑡𝑛 ∴ 𝑇𝑅𝐴𝑁𝑆𝐼𝑇𝐼𝑂𝑁
𝐼𝐹 Ø𝑀𝑡𝑛 >𝑀𝑢𝑇𝐸𝑁𝑆𝐼𝑂𝑁
∴
Ø=0.9
𝑅𝑛= 345910085.4/((0.9)(350)(475)^2 )=
𝑘𝑁 𝑚
1.53129490392648
𝜌 =(0.85(21))/345 [1−√(1−(2(1.531294904))/((0.85)(21)))] =
0.004647245392012
𝑆𝑝𝑎𝑐𝑖𝑛𝑔= (350−100−3(20))/(4−1)=95.00
ADJUSTED RIGHT SUPPORT :
𝐼𝐹 𝑀𝑢>Ø𝑀𝑡𝑛 ∴ 𝑇𝑅𝐴𝑁𝑆𝐼𝑇𝐼𝑂𝑁
𝐼𝐹 Ø𝑀𝑡𝑛 >𝑀𝑢𝑇𝐸𝑁𝑆𝐼𝑂𝑁
∴
Ø=0.9
𝑅𝑛= 67946000/((0.9)(350)(475)^2 )=
𝑘𝑁 𝑚
0.956018115464099
𝜌 =(0.85(21))/345 [1−√(1−(2(0.956018115))/((0.85)(21)))] =
0.002849536203544
𝑆𝑝𝑎𝑐𝑖𝑛𝑔= (300−100−2(20))/(4−1)=210.00
275
75
PRELIMINARY :
𝑀𝑢𝑚𝑎𝑥= ⌊0.65+.25((800−345)/(1000−345))⌋[(51/140)(0.85)(21)(250)
345910085.357526 𝑘𝑁 𝑚
∴𝐴𝐷𝐽𝑈𝑆𝑇!
PRELIMINARY :
3/14 (0.85))]= 𝑀𝑢𝑚𝑎𝑥= ⌊0.65+.25((800−345)/(1000−345))⌋[(51/140)(0.85)(21)(250)
345910085.357526 𝑘𝑁 𝑚
∴𝐴𝐷𝐽𝑈𝑆𝑇!
∴𝐴𝐷𝐽𝑈𝑆𝑇!
PRELIMINARY :
3/14 (0.85))]= 𝑀𝑢𝑚𝑎𝑥= ⌊0.65+.25((800−345)/(1000−345))⌋[(51/140)(0.85)(21)(250)
345910085.357526 𝑘𝑁 𝑚
𝑀𝑢𝑚𝑎𝑥= ⌊0.65+.25((800−345)/(1000−345))⌋[(51/140)(0.85)(21)(250)
∴𝐴𝐷𝐽𝑈𝑆𝑇!
As
250
MINARY :
51/140)(0.85)(21)(250) (275)^2 (1−3/14 (0.85))]=115668390.2 kNm
∴𝐴𝐷𝐽𝑈𝑆𝑇!
MINARY :
51/140)(0.85)(21)(250) (275)^2 (1−3/14 (0.85))]=115668390.2 kNm
∴𝐴𝐷𝐽𝑈𝑆𝑇!
∴𝐴𝐷𝐽𝑈𝑆𝑇!
MINARY :
51/140)(0.85)(21)(250) (275)^2 (1−3/14 (0.85))]=115668390.2 kNm
51/140)(0.85)(21)(250) (275)^2 (1−3/14 (0.85))]=115668390.2 kNm
∴𝐴𝐷𝐽𝑈𝑆𝑇!