Index

adaptive protection 39, 102 recloser-recloser 120


alarms processing 269, 274 electronic 111,120, 122
expert systems 271-2 hydraulic 111,120, 122
fingerprinting approach 273-4 recloser-relay 122
hypothesis approach 275 recloser-sectionaliser 123
processing methods 270 time/current devices 117
rules 273 coverage 190, 194, 212, 318, 337
amplitude comparator 174-5 instantaneous overcurrent units 68-9
distance protection 173 transformer differential protection 152
asymmetric current 13 current transformers 5, 26, 51, 60, 72, 92,
asymmetrical fault calculations 23 149, 170, 226-7, 265, 285, 289
a.c. saturation 52
accuracy classes 58
burden 53
back-up protection 3, 5, 7, 8-9, 117, 186, d.c. saturation 59
252, 301 equivalent circuit 51 2, 60
blocking characteristic errors 52, 72, 150
impedance protection 1984 excitation curve 52-4, 56
busbar differential protection 168, 266 flux density 56
installation tests 283
knee point 53-4
cabling lists 268 magnetisation curve 51, 53-4, 56
compensation transformer 154, 156-8, saturation density 56
172, 329 saturation point 53
computerised protection secondary injection test 53, 285-6
adaptive 39 selection 53, 92, 154, 304
architectures 40 tests 58
co-ordination 19, 68, 71, 73, 85~, 88-9,
94, 96-9, 102, 109, 111,113-14, diagrams
117, 120-3, 125, 128, 137, 142, 144, a.c. connections 262, 264-5
186-7, 219, 225,227, 230, 236-7, d.c. connections 262, 265
242, 252,286, 292, 305, logic 262, 268
fuse-fuse 117 single line 28, 60, 89, 104, 154, 243,
overcurrent relays 86, 88-9, 109 262-3
Dy transformers 75, 86 substation design 261-8
fuses 96 substation layout 263-4
recloser-fuse 117 wiring 262, 266, 285
340 Index

differential protection phase units 195


busbar 152, 168 polygonal relay 184, 203
high impedance 169-70 power swing blocking unit 199
multiple restraint 168 power system oscillations 196-7
compensation transformer 154, 156-7, reactance relay 180
172 fault resistance 180, 182-3, 193
line 164 relay characteristic angle 193,201
operating characteristics 164 residual compensation 194, 207, 222,
percentage biased 150 336
rotating machines 152, 164 series compensated lines 214
transformer 149, 152 setting 185
coverage 152 tee circuits 215
magnetisation inrush 153 under reach 213, 217 18
sensitivity 153, 155, 162
variable percentage characteristic 150, equivalent impedances 26, 301, 312
152, 168 excitation curves 52, 56
variable tappings 150 current transformer 51, 53, 55, 59
directional earth fault relays 131-2
directional overcurrent relays 127, 137,
141,261 fault calculations 11, 16, 23, 28
connections 138 computer 28
instantaneous units 137 interactive program 28
co-ordination 137 fault currents 7, 11, 23, 59, 139
time delay units 141 asymmetrical values 23
pick-up setting 141 mathematical derivation 24
time dial setting 146 frequency relays 239
discrimination margin 71-2, 88, 98-9, settings 240, 242-3,247, 249
104,235 frequency variation 240-1,243,250
distance protection 173524 fuse-fuse co-ordination 117
fuse-links 115, 118
amplitude comparator 174-5
fuses 109, 114-17
arc resistance, effect 179-80, 182, 193
classification 115
blocking characteristic 198
maximum clearance time 114
directional relay 179
minimum melting time 114, 117-18,
earth fault units 196
123
effect ofinfeeds 188
nominal current 116, 123
effective cover 199 200, 208
nominal voltage 114, 116
generator excitation loss detection 219 notation 117
impedance relay 179 speed ratio 115
infeed constant 188-9, 199
intertripping 212
permissive over reach 214 generator protection schemes 251
permissive under reach 213
under reach 213 impedance protection
lens characteristics 183 blocking characteristic 198-9
maximum load impedance 200 impedance relays 168, 179, 252
mho relays 200 impedances, equivalent 26
polygonal relays 202-3 industrial plant 225-6
mho relay 181 load shedding 239-50
polarised 182 automatic system 240
reach 185 industrial system protection 225-37
overlap 186, 188-9, 192, 207, 210 low voltage breakers 227, 236
overreach 189,214-15, 217-18 motors 226
phase angle comparator 176-7 moulded case circuit breakers 225
Index 341

overcurrent relays 225~5 selectivity 6 5 ~ 8 , 72, 88


thermal relays 226 transformers 63, 67-8, 71, 73
thermal relay-contactor and fuse 225 inverse time 66 7, 79
inertia constant 239-41 negative-sequence units 96
infeed constant setting 66
distance protection 188-9 software techniques 98
intertripping time/current curves 66
distance protection 212, 214 IEC/UK 73-4
IEEE/US 75
typical 74
load shedding 239 time delay units 97, 141
automatic system 240 2 co-ordination criteria 117
frequency relays 239 pick-up setting 141
setting 240, 242-3,247, 249 time dial setting 142
frequency variation 240-1,243,250 voltage control units 97
modelling parameters 241
voltage variation 242
low voltage breakers 227, 236 periodic maintenance 290
pilot differential protection 164, 166
polygonal relay 183,202
maintenance criteria 291 power system oscillations 196, 198
mho relay 181-2, 201
distance protection 193
motor pre-commissioning tests 185
locked rotor current 226, 230
primary injection test 189
service factor 230
protection
motor protection 252
computerised 39
low voltage breakers 226, 253
adaptive 39
thermal relays 226
architectures 42
moulded case circuit breakers 225
differential 149-70
busbar 168
negative sequence relays distance 173-222
co-ordination 96 generator 251
numerical protection 39-42 industrial systems 225-7
digital logic 39, 41, 99 line 261
logic schemes 100 motor 252
principles 99 overcurrent 63
performance tests 293 selectivity 63
setting parameters 291 transformer 258
protection equipment 283
installation 283
operator 'a' 263 testing 283
overcurrent relays 63 factory 285
ANSI/IEEE constants 72, 73 pre-commissioning 285
co-ordination requirements 73 primary injection 289
minimum short-circuit level 73 secondary injection 286
pick-up values 75 protection zones 5
thermal limits 73
definite current 63
definite time 66 reactances
definite time/current 66 synchronous machines 22
IEC constants 72, 73 recloser-fuse co-ordination 117
instantaneous units 67 recloser-recloser co-ordination 120
coverage 68 recloser-relay co-ordination 122
distribution circuits 68 recloser-sectionaliserco-ordination 123
342 Index

reclosers networks 22-3, 28


co-ordination 117-23 voltages 27, 32
installing 113 series compensated lines
operating sequence 111 distance protection 214
relay re-set time 122 software techniques 98
relay circuit supplies 43 symmetrical components 19, 22 3, 26
relays synchronous machines 14, 22
attracted armature 33 reactance values 16, 22
co-ordination requirements 73
computerised 33 tests
cup 35 factory 285
directional overcurrent 127 pre-commissioning 285
identification code 252 primary injection 289
impedance 179 secondary injection 285 6
induction 35 thermal limits 73
mho 181 thermal relays 226
moveable coil 34 thermal relay-contactors 225
overcurrent 63, 66, 70, 97-8, 127 transformers
polygonal 184,202-3 differential protection 152-64
reactance 180 inrush current 68
shaded pole 36 overcurrent protection 186
solenoid 33 protection schemes 154, 258
thermal 32, 226-7, 252 thermal capacity 74
wattmetric 36-7
residual compensation
distance protection 194, 207, 222, 336 voltage transformers
capacitor type 47
equivalent circuit 45
secondary injection test 285-6 inductive 47
sectionalisers 109, 113 burden 47
selectivity 5, 67, 88, 96, 237 equivalent circuit 45
sequence error limits 47, 49
components 19, 26, 28 errors 46
currents 22 flux density 45
impedances 22-3, 26, 28 magnetic impedance 51