GT-2500 Series

20.90

GT-2500-WP
Weatherproof Model GT-2500-FLP
Flameproof Model

• Provides a fast and reliable output by using Electro Chemical / • Approval& Compliance for Flameproof :
Pellister Sensor Technology. Certified to EX-d IIA, IIB, T6, IP66
Standard Compliance :
• Optimized for detection of smallest leak of Oxygen, Toxic and
• IS/IEC 60079-0 : 2004
Combustible Gases.
• IS/IEC 60079-1: 2007
• Highly resistant to poisoning and etching. • IS/IEC 60529 : 2001
• Capable of detecting down to PPM, %LEL & %V/V

• Digital display of Gas Concentration on LED Display

• Standard 4-20mA signal output with configurable range


• Gas Metering Skid • Gas Metering Station
• Easy handling and programming with 3 keys for Weatherproof Models. • Gas Cylinder Bank • Burner / Furnace Areas
• Oil & Gas Industries • Bullet Yard / Storage Yard
• Non-Intrusive programming for Flameproof Model using Magnetic Pen
• Gas Pipeline Project • Chemical Processing Plant
• Password protected programming with password changing facility • Acid Alkalizes & Dyes Mfg. Plants
• Refineries
• One man Auto Software Gas Calibration • Offshore Drilling & Processing Platforms
• Cold Storage
• Heat Treatment Plants
• Optional Alarm relay contacts with two configurable Alarm levels & • Sewage Plants
• Chemical Storage Area
one Relay for fail safe relay. • Fertilizers Plants
• Control Atmosphere
• Stack Monitoring
• Optional STEL and TWA set points can be configured for Toxic Gases • Power & Industrial Plants
• Chlorination Plant • Coal Mine and Confined Area
• Optional RS-485 communication port with MODBUS RTU Protocol. • Ambient Monitoring • Chemical & Petrochemical Plants
• Pulp & Paper Plants • Automotive Industries / Paint Shops
TECHNICAL SPECIFICATIONS
General : Output Signal :
Detection Method : Electrochemical / Catalytic Bead / Pellistor /Siegistor Standard : 4-20mA Current Output with configurable range selection.
Gases Detected : Oxygen / Toxic / Combustible with 470 ohm load driving capacity.
(Please select from the table below). Optional : Three SPDT Relays (one for FailSafe and Two for
Alarm indication) of rating ‘2A/120VAC, 2A/24VDC’.
Display : 2-Line, 4-Digit 8 mm (H) Seven Segment LED
Display & 8 LEDs to indicate status of instrument Optional : RS-485 Communication port with MODBUS RTU protocol.
Control Action : ii) Two independent Alarm set points with Latch & Error Monitoring :
Non-latch facility.
ii) User selectable Hysteresis and Logic option.
iii) Configurable STEL and TWA set points for
Toxic Gases (optional).
Setting : By using 3 Keys on front panel for Weatherproof Model Environmental :
By using Magnetic pen for Flameproof model
Operating Temperature : -150C to +500C
Performance : Storage Temperature : -200C to +600C
Humidity : Less than 95% Non-Condensing.
Accuracy : ±2% of Full Scale.
Response Time : For response time, contact to factory Accessories (Optional) :
Start-up Time : Less than 30 Seconds. • CE certified 24 VDC Power supply. • Gas Sampling & Conditioning System.
• Canopy & Mounting stand. • RS-485 to USB OR RS-232 convertor
Electrical :
• Gas Calibration Kit (0.5,1, 3,10)Liter. • PC Based SCADA Software, Modem
, 150mA
• Hooter Cum Flasher.
Flameproof Housing :
Weatherproof Housing : Protection Class : IP-66 for Gas Gr. IIA, IIB & IIC, CMRI (CIMFR)
tested Enclosure, CCOE (Optional).
Protection Class : IP-65
Cabinet Material : Cast Aluminium alloy, LM-6
Cabinet Material : Polycarbonate, grey colour Cable Entry : Double compression cable gland (Ex-Proof), ¾” ET-type
Cable Entry : Thermoplastic cable gland (IP 68) Dimension : 215mm (W) x 185 mm(H) x 125 mm (D) (with 1 Gland)
Dimension : 170mm(H)x100mm(W)x 60 mm(D) (with 1 Gland) 260 mm (W) x 185 mm (H) x 125 mm (D) (with 2 Glands)
: 170mm(H)x120mm(W)x60 mm (D) (with 2 Glands) (Tolerance ± 5mm)
Mounting : Wall Mounting / Stand Mounting / Pipe Mounting Mounting : Wall Mounting / Stand Mounting / Pipe Mounting
Weight : Approx 500 Grams Weight : Approx 2 kg

LIST OF GAS TRANSMITTERS WITH RANGES & RESOLUTION


S.N. GASES RANGE UNIT RES. S. N. GASES RANGE UNIT RES. S. N. GASES RANGE UNIT RES.
O1 Oxygen (O2 ) 25 %Vol. 0.1 T13 Hydrazine (N2H4) 1 PPM 0.01
COMBUSTIBLE GASES
O2 Oxygen (O2 ) 100 %Vol. 0.1 T14 Bromine (Br2) 20 PPM 0.01
T15 Hydrogen Fluoride (HF) 10 PPM 0.01 C12 Acetone (CH3 ) 2CO 100 %LEL 1
TOXIC GASES
100 PPM 1 C13 Ethanol (C2H5OH) 100 %LEL 1
T1 Carbon Monoxide (CO) 1000 PPM 1 T16 Phosgene/Cobalt (II) C14 Ethyl Acetate (CH3COOC2H5 ) 100 %LEL 1
5000 PPM 1 Chloride (COCL2) 1 PPM 0.01 C15 Ethylene (C2H4 ) 100 %LEL 1
T2 Sulphur Dioxide (SO2) 50 PPM 0.1
2000 PPM 1 COMBUSTIBLE GASES C16 Hydrogen (H2) 100 %LEL 1
T3 Hydrogen Sulfide (H2S) 100 PPM 1 C17 Isopropanol (CH3C2H4OH) 100 %LEL 1
C1 Methane (CH4 ) 100 %LEL 1
2000 PPM 1 C18 Methanol (CH3OH) 100 %LEL 1
C2 Butane/n-Butane(C4H10 ) 100 %LEL 1
T5 Ammonia (NH3) 100 PPM 1 C19 Methyl ethyl ketone (CH3-CO-C2H5) 100 %LEL 1
C3 Propane/n-Propane (C3H8 ) 100 %LEL 1
1000 PPM 1 C20 N-heptane (C7H16) 100 %LEL 1
C4 Acetylene (C2H2 ) 100 %LEL 1
T6 Hydrogen (H2) 1000 PPM 1
C5 Hexane/n-Hexane (C6H14 ) 100 %LEL 1 C21 N-pentane (C5H12) 100 %LEL 1
T7 Chlorine (CL2) 20 PPM 0.01
C6 CNG 100 %LEL 1 C22 N-octane (C8H18) 100 %LEL 1
T8 Hydrogen Chloride (HCL)/ 20 PPM 0.01
C7 LNG 100 %LEL 1 C23 Toluene (C6H5CH3) 100 %LEL 1
Hydrogen Bromide (HBR) 200 PPM 1
C8 LPG 100 %LEL 1 C24 Ammonia (NH3) 100 %LEL 1
T9 Nitrogen Dioxide (NO2) 20 PPM 0.01
C9 Natural Gas 100 %LEL 1
T10 Hydrogen Cyanide (HCN) 100 PPM 1 C25 Carbon Monoxide (CO) 100 %LEL 1
C10 Pentane/n-Pentane (C5H12) 100 %LEL 1
T11 Ozone (O3) 5 PPM 0.01 C26 Unleaded Petrol 100 %LEL 1
C11 Flammable (Explosive) Gas 100 %LEL 1
T12 Phosphine (Ph3) 10 PPM 0.01
* Please specify if any other gases and gas range you require which is not in the list available on Request
ORDERING INFORMATION
GT A B C D E F G
Specifications subject to change without any prior notice

A) Model No. B) Enclosure C) Gas D) Retransmission E) Relay Output F) Communication G) Sensor Housing
1) 2500 1) FLP Please select the Output 1) None Port 1) PVC material
(Flameproof) Serial No of the 1) None 2) 3 Relays 1) None 2) Teflon
2) WP gas from the list 2) 4 to 20mA (AL1, AL2 2) RS-485 serial port 3) Stainless
(Weatherproof) given above. Failsafe Relay) Steel (SS316)
* Before placing order please Refer the above ordering information or Contact below address for assistance.
ATEX
ISO 9001:2008 Certified

AMBETRONICS ENGINEERS PVT. LTD.


17-B, Tarun Industrial Estate, Mogra Pada, New Nagardas Road, Andheri (E.) Mumbai - 69, India.
Mob.: 9320619646 • 9320621646 • Tel.: +91-22-61673000, 28371143 • Fax : +91-22-28226570
E-mail : project@ambetronics.com • gas@ambetronics.com • Web : www.ambetronics.com
Version GT-2500-WF-R0-13-3-18