You are on page 1of 1

ABB Automation Technology Products AB

Robotics
Created by: Approved by: Versioin

Russell Drown Per Norlin 1.0


To Dept. Date Filnamn Page
ABB SolutionsBank ISC 3/5/2003 TSG_WW_SDK9 A Page
drive is constantly
accessed when th VC is 1 of 1
running.doc
Type of doc:
Software Support, Industrial Software Products Technical Support

TSG_WW_SDK 9: A: drive is constantly accessed when the VC is running

Product: Virtual Controller

Version: 4.X

Problem: When VC is running, the PC floppy drive is repeatedly accessed

Solution: Reduce the number of mapped drives on the system

On systems that have a large number of physical and logical drives (>10), users may
experience continuous access of the A: drive when the Virtual Controller is running.

This symptom occurs when the total number of drives is greater than 10 because of a limitation
in the VC’s ability to recognize more than 10 drives.

As a workaround, disconnect mapped network drives (if possible) until less than 10 total drives
are connected.

If you have any further questions, please contact your local ABB Support Center
or ABB Robotics Software Support phone: +46-31-773 8590,
e-mail: support_software.serop@se.abb.com