You are on page 1of 2

Pietro Fiorentini Multiphase Flowmeter

Flowatch HS

TECHNOLOGY
MPFM Flowatch HS (High Speed) fulfills the essential requirements of well testing as a simple device to
constantly monitor well output stream of each single phase
The Flowatch HS is based on the 15+ years field proven technology platform of Pietro Fiorentini MPFMs.
Installation and maintenance of the MPFM has been developed to allow operators manage themselves
their well flow monitoring device. Furthermore, the Flowatch HS has the essential advantage of
employing a radioactive source so it is possible to reach high performances in terms of accuracy

KEY FEATURES

• Radioactive type • All flow patterns

• High accuracy due to patented fast gamma • Skid mounted version available
densitometer
• Smart Calibration on factory
• Wide size range
• Designed for safe operations
• Cross correlation for reliable velocity
measurement • Retrievable Venturi

• Onshore and offshore installation • High repeatability and long term


stability

V.3.5
Copyright 2018 Pietro Fiorentini S.p.a.
SPECIFICATIONS

Operating Range • 0-100% water cut


• 0-98% gas volume fraction (GVF)
Typical Uncertainty • Liquid flow rate: 0.7% FS + 1% relative
95% confidence level • Water cut: ±2.5% absolute (GVF≤85%)
±4% absolute (GVF>85%)
• Gas Flow rate: 1.5% FS + 1.5% relative
Size Starting from 0,5”
Design Pressure & Up to 10.000 psi, up to 302°F (150°C)
Temperature
Body Material AISI316, Duplex, Inconel 625, others on request

Meter Pressure drop <1 Bar


Density measurement • Gamma Source: Cs-137, 30 mCi, Half-life 30.1 yrs
• Dose level 0,4µSv/h @1 m (natural background)
• Detector: Pietro Fiorentini Fast Gamma
• Counts per second: 0.5 millions
• ATEX/IECEx certification Ex d IIB T3-T6 Ga
Communication • Communication ports:
Interface o RS-485 single or redundant
o RS-422 single or redundant
o Ethernet single or redundant
• Communication protocols:
o Modbus ASCII/RTU
o TCP/IP
Flow Electronic • Real Time controller, Linux Operating system
Transmitter • Ambient temperature -40° C/ + 75° C
• Power supply: 24VDC, or 110÷240 VAC, 50÷60Hz
• Power consumption: 18W@24VDC
• Enclosure for safe or hazardous area
• Weather protection: IP 66
• Stainless steel or aluminium enclosure
• Field display (optional)
• ATEX/IECEx certification Ex d (or Ex ia) IIB T3-T6 Ga
HMI • OS: minimum requirement Windows XP
• TCP/IP Wireless