Johann M. K.

Blumenthal FORM-OPS19
Reederei Port of: BALIKPAPAN Date: 09.09.2010
MV "CHRISTINA" At Sea:10.09.2010 enter date
RECORD OF TEMPERATURE / CO and CH4 READINGS
LOADPORT: BALIKPAPAN DATE ARRIVAL LOADPORT: 04.09.2010
DATE COMMENCED LOADING: 08.09.2010 Average air temperature in loading port: 27° C
TOTAL CARGO LOADED: 62292.0 MT DATE SAILED: 09.09.2010
DESTINATION: BRINDISI DATE OF ARRIVAL: 05.10.2010

INDICATE BELOW HOLDS LOADED AND AMOUNTS OF COAL IN:


Hold 1 9200 MT Hold 2 9220 MT Hold 3 9220 MT Hold 4 8500 MT
Hold 5 8650 MT Hold 6 8752 MT Hold 7 8750 MT Hold 8 N/A
Hold 9 N/A

DISCHARGE PORT ARRIVAL DATE COMMENCED DISCHARGE COMPLETED DISCHARGE

1. BRINDISI 05.10.2010            


2.                        
3.                        

CO / METHANE / TEMPERATURE READINGS TO BE MONITORED AT REGULAR INTERVALS THROUGHOUT THE VOYAGE AND RECORDED BELOW!!!

Date Time Hold 1 Hold 2 Hold 3 Hold 4 Hold 5 Hold 6 Hold 7


CO CH4 C° CO CH4 C° CO CH4 C° CO CH4 C° CO CH4 C° CO CH4 CO CH4 C° CO
03.10.10 0.375 0 0 37 0 0 33 0 0 33 0 0 34 0 0 41 0 0 37 0 0 37
04.10.10 0.375 0 0 37 0 0 32 0 0 32 0 0 33 0 0 41 0 0 37 0 0 36
05.10.10 0.375 0 0 37 0 0 32 0 0 32 0 0 33 0 0 40 0 0 37 0 0 35

Date Time Hold 1 Hold 2 Hold 3 Hold 4 Hold 5 Hold 6 Hold 7 CO


CO CH4 C° CO CH4 C° CO CH4 C° CO CH4 C° CO CH4 C° CO CH4 C° CO CH4 C°
-
-
-
-

Indicate type of instrument used: CO = Carbon Monoxide = Toxic but it is also a flammable gas in concentration in air of 12% to 75% by volume
Thermometer: STANDARD THERMOMETER ONLY CH4 = Methane = Explosive if within 5–15% in air
Gas Monitor RKI GX - 2001 S/N: 0820014530 C° = Temperature of the cargo in Centigrade
Instructions:

Note: Development of the temperature of the cargo is to be based on the first measurement after sailing and then compared by further readings during the sea voyage.