You are on page 1of 2

IMPACT 4.07.

80 08/09/2020

Chassis ID Path
MHHK 805320 364/Diagnostics//IECU-P107B, Range neutral valve

Model Identity
UD-HDE 132455160

Publish date ID/Operation


14/11/2013

IECU-P107B, Range neutral valve

Fault Conditions for fault Observable symptoms Probable cause


type code
FTB 12
(Circuit Circuit Short To Power Take Off (PTO) cannot be Short circuit to voltage supply
Short Battery activated Short circuit to battery voltage
To Switch position: Unable to shift out of neutral position Damaged component
Battery S28B Pressed Damaged connector
) A149.PB:2 Damaged wires

Copyright to this documentation belongs to the Volvo Group. No reproduction, copying, change, amendment or other similar disposal is entitled without prior written consent by
the Volvo Group
The information contained herein is current at the time of its original distribution, but is subject to change. The reader is advised that printed copies are uncontrolled.

1/2
IMPACT 4.07.80 08/09/2020

FTB 14
(Circuit Circuit Short To Power Take Off (PTO) cannot be Short circuit to ground
Short Ground or Open activated Open circuit
To Switch position: Range Neutral Valve cannot be activated Damaged component
Ground S28B Not Pressed Not possible to lock neutral hold position Damaged connector
or A149.PB:2 Damaged wires
Open )

Resistance Measurement

Measurement Key position Measurement points Expected Measured Other (Special


Breakout box Wiring diagram Value value Tool PN)
Control Wire OFF 49 – 47 Y18F:3 – Y18F:1 287 KOhm –   88890167
Supply Wire 297 KOhm 9998699

Copyright to this documentation belongs to the Volvo Group. No reproduction, copying, change, amendment or other similar disposal is entitled without prior written consent by
the Volvo Group
The information contained herein is current at the time of its original distribution, but is subject to change. The reader is advised that printed copies are uncontrolled.