You are on page 1of 2

XPress DR Quick Start Guide

TM

WHAT’S
IN THE
BOX

Quick Start Guide XPress DR Device Server

1 HARDWARE REVIEW 2 HARDWARE INSTALLATION


WARNING - Do not connect or disconnect when the area is
Screw Terminals
known to be hazardous.
(RS-232 and RS-422/485)
1. Connect the XPress DR to the network through the Ethernet port.
(The unit must be on the same network as your computer.)

2. Connect power (9-30 VDC or 9-24VAC).


®

Reset Switch
Serial RJ45 Port
Status LEDs
(Fault/Ready/Activity/Link)
(RS-232 and RS-422/485) DC+ GND
Serial Data Activity LEDs
(Transmit/Receive)
RJ45 Ethernet Port 9-30VDC
(10/100BASE-T) RS-232 or RS-422/485
Select Switch 9-30VAC
(for Serial Screw Terminal Block)

DC- GND
Screw Terminals
(9-30VDC or 9-24VAC)
3. Verify that the green Link “L” LED is lit.

3 IP ADDRESSING 4 DEVICEINSTALLER
Your XPress DR must have a unique IP address on your network. INSTALL DeviceInstaller™
The IP address can be assigned automatically or manually.
DHCP REQUIREMENTS: Computer must have a working Ethernet adapter
Many networks use an automatic method of assigning an IP running Windows as the Operating System (OS). For device
address called DHCP. If you are unsure whether your network discovery, the computer and device should be connected to the
uses DHCP, check with your systems administrator. same IP subnet.
The XPress DR looks for a DHCP server when it first powers
up. You can use the DeviceInstaller™ graphical user interface 1. Download the latest version of DeviceInstaller from
to search the network if your unit has been assigned an IP http://www.lantronix.com/downloads. The minimum
address by the DHCP server. If the XPress DR does not acquire required version for DeviceInstaller is 4.4.0.2.
an IP address, or you do not use DHCP, you must assign a
2. Run the executable to start the installation process on the
fixed IP address.
computer being used to configure the XPress DR.
FIXED IP ADDRESS
In most installations, a fixed IP address is desirable. The 3. Follow the installation wizard prompts.
systems administrator generally provides the IP address.
The IP address must be within a valid range, unique to your
network, and in the same subnet as your PC.
The following section describes assigning an IP address using
DeviceInstaller.
XPress DR Quick Start Guide
TM

5 CONFIGURING 7 CONNECTING SERIAL DEVICES


1. Run DeviceInstaller The cable diagram below is for connecting a PC (COM Port) to the XPress
Click: Start > Programs > Lantronix > DeviceInstaller > DeviceInstaller. DR serial RJ45 port. You can use the serial RJ45 port to configure and test
port settings prior to connection to your automation device.
2. U
 pon launch, DeviceInstaller will search for Lantronix devices on
the network. Select the unit from the list of Lantronix devices on RS-232 Configuration
the local network. (You may also click on the Search icon if your 4 DTR (Out) 1 No Connection
device isn’t found immediately.) 6 DSR (In) 2 DTR (Out)
3 TXD (Out) 3 RXD (In)
2 RXD (In) 4 TXD (Out)
3. Note the device IP address. 5 Signal Ground 5 Signal Ground
7 RTS (Out) 6 CTS (In)
4. Access Web Manager by entering the device IP address in the address 8 CTS (In) 7 RTS (Out)
bar of a browser. The device does not have a factory default username. 8 No Connection

The factory default password is the last 8 characters of the Device ID (for DTE, 9-PIN, FEMALE SERIAL RJ45

devices manufactured after January 1, 2020) or is left blank (for all older
devices). The cable diagram below is for connecting a PC (COM Port) to the
5. Assign an IP address in the network settings and perform other XPress DR serial screw terminals.
configuration. RS-232 Configuration

If DeviceInstaller is unable to discover the XPress DR: 5


GND

• In Windows Device Manager, ensure that the Ethernet adapter is 9


4
RXD CTS RTS TXD
CTS
3 TXD
8
installed and working properly. RTS
2 RXD
7
GND
• If your PC or laptop has more than one network interface, 6
1
GND

make sure the correct interface is selected in DeviceInstaller.


®

DTE, 9-PIN, FEMALE


 o to Tools>Options and make sure the correct network
•G
interface is selected. If not, check the correct interface, For additional configurations, please refer to the XPress DR User
click on OK, and restart DeviceInstaller. Guide: http://www.lantronix.com/support/downloads.
•C
 heck the Link “L” LED indicator on the XPress DR to make
sure there is a physical connection between the Ethernet
adapter and the unit.

Contact Technical Support


For technical support queries, visit http://www.lantronix.com/support or call (800) 422-7044 Monday – Friday from 6:00 a.m. – 5:00 p.m.,
Pacific Time, excluding holidays.
Latest Firmware For the latest firmware downloads, visit http://www.lantronix.com/support/downloads.
IP Address Assignment Tutorial To view a tutorial on how to assign an IP address, visit http://www.lantronix.com/support/tutorials.

© 2020, Lantronix, Inc. Lantronix is a registered trademark, and XPress and DeviceInstaller are trademarks of Lantronix, Inc. All rights reserved. 900-289 Rev E

You might also like