Choke Manifolds

Engineered configurations for all pressure-sensitive applications


Choke Manifolds:
Tailored solutions that keep
the lid on pressure, and flow

The inability to precisely contain and control Available in pressure ratings from 5,000
to 15,000 psi and bore sizes ranging from
wellhead pressures during critical onshore 2 1/16-in. to 4 1/16-in., our durable and
cost-efficient Manifolds are configured
and offshore operations can have profound with redundant parallel chokes providing
alternate flow regimes that allow
HSE and economic ramifications. With our operations to continue uninterrupted during
routine maintenance.
all-inclusive suite of customized manifolds,
M-I SWACO can design application-specific
configurations of chokes, gate valves,
fittings and technical specifications to give
you precise pressure and flow control in
any operation requiring a choke to control
surface casing pressure.
Uniquely configured manifolds keep the
pressure off your most demanding applications
Features Our suite of rugged Manifolds are Regardless of the application, you can
■■ Allows for multiple choke and gate engineered to accommodate the full gamut count on our industry-recognized
valve configurations of M-I SWACO, a Schlumberger company, specialists to ensure a configuration of
chokes from the industry-standard pressure-control equipment that is of the
■■ Pressure ratings from 5,000-15,000 psi
AUTOCHOKE† and SUPERCHOKE† to utmost integrity. For you, this means not
■■ Available bore sizes from
manually adjustable and positive chokes, having to concern yourself the physically
2-1/6 to 4-1/6-in.
as well as competitive hydraulic chokes. dangerous and economically harmful
■■ Dual-choke configurations In addition, gate valves are available in consequences of improperly designed
■■ Adaptable for all location requirements either hydraulically or manually adjustable pressure control systems. In addition, our
■■ Meets H2S service requirements per configurations, giving us the flexibility to Choke Manifolds help to safely manage
NACE MR0175 and standard service configure a manifold to meet your most hydrogen sulfide emissions and prevent
Manifolds optionally available demanding applications, including: release of toxic fluids.
■■ Optional double-block and ■■ Managed pressure drilling What’s more, our manifolds are designed to
bleed configurations ■■ Underbalanced drilling accommodate parallel chokes, which
■■ Accommodates remotely operated , ■■ Well control allows us to periodically service the
manual and positive chokes equipment without interrupting the
■■ Frac plug drill out
monogrammed to API 6A operation. By incorporating dual chokes on
■■ Frac flow back our manifolds, we can safely isolate one
and/or API 16C
■■ Well testing choke for servicing while controlling
■■ Hydraulic or manually operated gate-
Our Manifolds are designed to direct flow pressure and flow through the other.
valves monogrammed to API 6A
from the well through the drilling chokes That way you are assured our equipment
■■ Manifolds available with API 16C continues to deliver the utmost in safe
to protect downstream equipment from
monogram option pressure control without unnecessary and
the high well flow pressures encountered
profit-reducing downtime.
Benefits during operations.
■■ Regulates pressure and flow control
■■ Adaptable to variety of chokes
and gate valve configurations
■■ Facilitates application-specific
configurations
■■ Allows for safely circulating out a kick
■■ Offers small footprint configurations
■■ Meets all industry safety,
durability standards
■■ Minimizes downtime
■■ Reduces blowout risks
■■ Assures equipment integrity
■■ Contains harmful H2S emissions
■■ Enhances HSE profile
Flat Design MPD Manifolds
Engineered specifically for MPD/UBD Design Specifications ■■ Connections:
applications, our flat design MPD Manifolds ■■ All components certified to API 6A - Inlet: 4-in. Fig 602 female union
feature double block and bleed valves that - Outlet: 4-in. Fig 602 male union
■■ Skid-lift tested in accordance with
for two pressure barriers. - Gauge port: 2-in. Fig 1502 female union
M-I SWACO T-1067 @ 2.5X rated load
- Bleed ports: ( ¼ NPT) upstream and
These dual barriers optimize safety Service: Sour Gas
■■
downstream of chokes
during both operation and maintenance.
■■ Rated pressure: 5,000 PSI Approximate weights:
Isolation of the gauge port allows for ■■

safe connections while the dual choke ■■ Material Class: DD and EE - With chokes: 14,000 lb ((6364 Kg)
flow paths provide safety-enhancing ■■ Temperature Class: - Without chokes and adapters:
redundancy. P-U -20°F - +250°F (-6°C - +121°C) 12,350 lb (5614 Kg)
- Skid only: 1,650 lb (750 Kg)
DNV, ABS, CE and PED-certified units are ■■ Product specification level: PSL2
■■ Dimensions:
available upon request. ■■ Performance requirement: PR 1
- Length: 162 in (4m)
■■ Ring groove inlay option available - Width: 81 in (2m)
- Height: 48 in (1.2 m)
MPD L-Shape Manifolds
Our MPD L shape Manifolds are configured Design Specifications ■■ Connections:
in a cost-effective space-saving design ■■ All components certified to API 6A - Main inlet: 4 1/6-in. 5K flange
making them ideal for installation in - Pump inlet: 4-in.
■■ Skid-lift tested in accordance with
closed containers for use in MPD/UBD - Outlet (s):
M-I SWACO T-1067 @ 2.5X rated load
applications in harsh environments. Three 4-in. Fig 1502 male union
The design reduces the wellsite footprint ■■ Service: Sour Gas - Gauge/transducer port:
and, if necessary, provides assistance in ■■ Rated pressure: 5,000 PSI 2-in Fig 1502 female union
modular designs. ■■ Material Class: DD and EE ■■ Approximate weights:
The MPD L shape Manifold is a double ■■ Temperature Class: - With chokes: 11,500 lb (5227 Kg)
block/double bleed design with a single P-U -20°F - +250°F (-6°C - +121°C) - Without chokes and adapters:
gate valve in the gut line. 9,800 lb (4455 Kg)
■■ Product specification level: PSL 2
- Skid only: 1,700 lb (773 Kg)
■■ Performance requirement: PR 1
■■ Dimensions:
■■ Ring groove inlay option available - Length: 86-in (2.1m)
- Width: 87-in (2.2m)
- Height: 66-in (1.6 m)
MPD U-Shape Manifolds

The compact MPD U shape Manifold is Design Specifications ■■ Approximate weights:


the configuration of choice for offshore ■■ All components certified to API 6A - Max. gross weight (MGW) dry:
and other applications where space is a 20,000 lb (9091 Kg)
■■ Temperature Class: P-U
premium. The design is ideal for offshore - Tare weight (skid and lift frame only):
MDP/UBD applications in areas where ■■ Material Class: EE 3,900 lb (1773 Kg)
regulations require DNV and/or Norsok- ■■ Product specification level: PSL3 - Without chokes and adapters:
approved equipment. ■■ Performance requirement: PR 1 9,800 lb (4455 Kg)
The lifting frame and skid of the ■■ Rated pressure: 5,000 PSI ■■ Dimensions:
M-I SWACO MPD U shape Manifold is - Length: 88 in (2.2m)
■■ Ring groove inlay option available
available certified to DNV 2.7-3. - Width: 99 in (2.5m)
■■ Connections: - Height: 96 in (2.4 m)
- General: 4 1/16-in 5K
- Inlet: 4 1/6-in. 5K flange
- Pump inlet: 4-in. Fig 1502 female union
- Outlet (s): 4-in. Fig 602 male union
Frac-Plug Drill Out (FPDO)/
Flow Back (FFB) Manifold (2-1/16-in)
Engineered specifically for drilling out frac Design Specifications ■■ Connections:
plugs for flow back operations, the ■■ All components certified to API 6A - Inlet: 2-in. Fig 2202 female union
2-1/16-in version of our FPDO/FFB - Outlet:
■■ Skid-lift tested in accordance with
Manifolds feature dual isolation valves - (2) 3-in Fig 2202 male union
M-I SWACO T-1067 @ 2.5X rated load
upstream of the choke, thereby enhancing - (1) 2 1/16-in 15K flange
safety during maintenance or choke ■■ Temperature Class: - Gauge port: 2-in. Fig 2202 female union
change-outs. P-U -20°F - +250°F (-6°C - +121°C) ■■ Approximate weights:
■■ Rated pressure: 15,000 PSI - With chokes: 6,350 lb (2886 Kg)
The light weight design optimizes mobility
while the lifting eyes, forklift pockets and ■■ Material Class: ■■ Dimensions:
drag lugs simplifies on-location movement Chokes & valves (EE-0.5); - Length: 159 in (4m)
and set-up. fittings (DD-NL) - Width: 61 in (1.5m)
■■ Product specification level: PSL 3 - Height: 52 in (1.3 m)
■■ Performance requirement: PR 1
■■ Ring groove inlay option available
FPDO/FFB Manifold (3-1/16-in)
Also engineered specifically for drilling Design Specifications Connections:
out frac plugs for flow back operations, ■■ All components certified to API 6A - Inlet: 3-in. Fig 2202 female union
the 3-1/16-in. version of our FPDO/FFB - Outlet:
■■ Skid-lift tested in accordance with
Manifolds likewise features dual isolation - (2) 3-in Fig 2202 male union
M-I SWACO T-1067 @ 2.5X rated load
valves upstream of the choke to improve - (1) 3-1/16-in 15K flange
safety during maintenance or choke ■■ Temperature Class: - Gauge port: 2-in. Fig 2202 female union
change-outs. The isolation valve at the P-U -20°F - +250°F (-6°C - +121°C)
Approximate weights:
gauge port facilitates safe connection ■■ Rated pressure: 15,000 PSI
- Dry weight with chokes:
and maintenance. Material Class:
■■
10, 450 lb (4724 Kg)
Though larger, the 3-1/6-in. also is a light Chokes & valves (EE-0.5);
fittings (DD-NL) Dimensions:
weight design optimizes mobility while the
- Length: 172 in (4.3m)
lifting eyes, forklift pockets and drag lugs ■■ Product specification level: PSL 3
- Width: 70 in (1.7m)
simplifies on-location movement Performance requirement: PR 1
■■
- Height: 53 in (1.3 m)
and set-up. ■■ Ring groove inlay option available
Choke and Kill/Well Control Manifolds
M-I SWACO offers a comprehensive Design Specifications ■■ Product specification level: PSL 3
suite of Manifolds designed specifically ■■ Chokes and Manifold assembly ■■ Performance requirement: PR 1
for choke and kill applications to circulate certified to API 16C ■■ Ring grooves: all with 316SS inlay
out a kick. These Manifolds feature dual-
■■ All other components certified to API 6A ■■ Connections size: 3-1/6-in. 10K
isolation valves upstream of the choke,
thus enhancing safety during maintenance ■■ Skid tested in accordance with ■■ Approximate weights:
or choke swaps. An isolation valve at DNV 2.7-3 and Shell OPS0055 - Skid and Manifold (no chokes):
the gauge port allows for connections ■■ Service: Sour gas 12,000 lb (5455 Kg)
and maintenance of gauges to be carried ■■ Temperature Class: - Skid and Manifold (one choke):
out safely. Buffer chamber absorbs P-U -20°F - +250°F (-6°C - +121°C) 12,500 lb (5682 Kg)
downstream expansion of gases reducing - Skid and Manifold (two chokes):
■■ Rated pressure: 10,000 PSI
Manifold outlet velocities. 13,000 lb (5909 Kg)
■■ Material Class: EE; Chokes & valves - Skid only: 2600 lb (1182 Kg)
The skid incorporates lifting eyes and (EE-0.5); fittings (DD-NL)
forklift pockets, making on-location
■■ Dimensions:
■■ Optional Chokes include: - Length: 179 in (4.5m)
movement and set-up much easier.
- Manual choke (8275100) - Width: 124 in (3.1m)
- SUPERCHOKE (CH1ZZ3PUB10A) - Height: 60 in (15 m)
- AUTOCHOKE (CH2ZZ3PUB10A)
Manifolds complement industry-leading suite
of pressure control technologies

Our versatile and durable 5 to 15K Choke ■■ LOW-PRESSURE AUTOCHOKE Our industry-leading pressure control
Manifolds complement a growing CONSOLE† (LPAC†): Engineered for low- offerings also extend to technologies
portfolio of new generation pressure surface pressure managed pressure for safe and cost-effective drilling and
control equipment and services that drilling (MPD) and underbalanced drilling monitoring in sour gas and similarly
is second to none. The driving force (UBD), the LPAC is precision-built to hostile environments. Along with our
behind our development of industry- accurately and safely control dual highly reliable D-Gassers and Mud/
leading chokes, operating consoles, AUTOCHOKE configurations. Gas Separators, we also offer the novel
the closed-loop Pressure and Fluid With the LPAC, operators easily can CARBONTRACKER† technology that allows
Management System† (PFMS†) and control both chokes and transition operators to measure produced gas
other advancements is to allow you to drill seamlessly between the two units. during drilling.
safely and efficiently in applications where PRESSURE and FLUID MANAGEMENT
Put our Choke Manifolds to
■■

precise pressure control is paramount. SYSTEM (PFMS): The closed-loop


PFMS was engineered specifically for work for you
The M-I SWACO line of high performance
pressure control technologies include: coiled tubing drilling and completions, but To find out more about how our wide
is ideal for any operation requiring the range of Choke Manifolds and how they
■■ New generation 10K and 15K Drilling
utmost in pressure control. With the are performing for our other customers,
Chokes: The AUTOCHOKE, 10K
PFMS, we have effectively addressed contact your local M-I SWACO
SUPERCHOKE, 15K SUPERCHOKE and
the limitations of narrow-pressure representative.
the remotely controlled eCHOKE† are
gradients, solids removal specifications,
routinely re-writing industry standards
as well as the space, weight and time
for safe and effective well-kill and high-
restrictions imposed with coiled tubing
pressure drilling, well testing and
applications.
cleanup applications.
Choke and Kill Manifold proves itself in the field
Texas: Clean bill of health follows successful 10K Manifold trial
The Situation The Solution The Results
M-I SWACO carried out the first field trial The Manifold was used successfully during The condition of the Manifold and all
of its newly engineered 10K Manifold, a 22-day drill-out. For the operation, the components were inspected at the
comprising two 10K AutoChokes as primary AutoChoke was set to 250 psi M-I SWACO facility in Tyler, TX.
well as nine gate valves, a buffer tank with the back-up unit programmed for During the inspection, both of the 10K
and transmitter flange. The Manifold was 275 psi. The fluid flowing through the AutoChokes were disassembled with
designed to divert flow to various pressure Manifold was thick with a significant the inspection showing no indications of
control components or several other volume of solids. The average flow rate was internal wear. The Manifold iron exhibited
destinations during critical operations. 1 bbl/min for the duration of the trial for an no sign of washout or damage. Owing to
aggregate of 31,680 bbl or more than the successful drill-out and the positive
1.3 million gal over the 22-day operation. inspection report, the new 10K Choke
While no issues with the Manifold were Manifold performed exactly as designed
recorded during the project, M-I SWACO with no post-operation integrity issues.
wanted to conduct a post-operation
inspection to determine if the Manifold
incurred any integrity problems that needed
to be addressed in subsequent operations.
This information is supplied solely for informational purposes and M-I SWACO makes no guarantees or
P.O. Box 42842
warranties, either expressed or implied, with respect to the accuracy and use of this data. All product Houston, Texas 77242-2842
warranties and guarantees shall be governed by the Standard Terms of Sale. Nothing in this document
is legal advice or is a substitute for competent legal advice.
www.miswaco.slb.com
E-mail: questions@miswaco.slb.com

©2012 M-I L.L.C. All rights reserved. †Mark of M-I L.L.C.


DBR.0323.1211.R1 (E)

You might also like