Lies SDG-7_1_10 Eotvor bebtaanatcinen Govt Automatic Guiding Computer Technical Description This program is protected by U.S. and intemational copyright law as described in the About Box Operator's manual Issued May 2014 English 2 SDG-7_1_10 potvorBebotaanacien Garona DF Version Date Edited Amendment Pages 1.0 09-2011 a First version - a Geaeu gs | Abtin-one computer instead ofa | Complete separate unit Copyright © Plasser & Theurer All rights reserved, particularly the right to produce copies, to distribute these copies, as well to translate the work. English SDG-7 3 peor basnaenen Conca RB ea Table of contents Page 1 GENERAL INFORMATION... citer 2 OPERATING INSTRUCTIONS FOR THE ALL-IN-ONE COMPUTER =) 2.1 OPERATING CONTROLS.... FUNCTION KEYS AND STATUS DISPLAY. 2.2 KEYBOARD 2.2.1 DESCRIPTION OF THE KEYS... 2.2.2. FUNCTION KEYS. 2.2.3. KEY COMBINATION: “SHIFT” KEY AND FUNCTION KEY. 2.2.4 KEY COMBINATION "CTRL" AND FUNCTION KEY..... 3. TURNING THE COMPUTER ON / OFF.......... sereanirarerceesee TO 3.1 TURNING THE COMPUTER ON.. 3.2 TURNING THE COMPUTER OFF. 4 STARTING AND CLOSING PROGRAWG............ 4.1 AWINDOW OR PROGRAM DOES NOT RESPOND......... 5 INSTALLATION OF ADDITIONAL PROGRAMS. 6 ELECTRICAL CONNECTIONS mance a a ee 13, 6.2 WELDING WORK.......... faeehieepaaabaniie sssaiis 13 7 RECOVERY OF THE SYSTEM 14 7.1. USING THE ANTI-VIRUS SOFTWARE 7.2 UPDATE OF THE ANTI-VIRUS FILE: 8 UPDATE WINALC PARAMETERS... = faa abies 9 TECHNICAL INFORMATION / STATUS PER 2014. 7 English 4 SDG-7_1_10 Coot von Bataan Gurls 1 General information The term WinALC means “Windows Automatischer Leit Computer’ (Windows Automatic Guiding Computer) The program is used to automatically output target values for the lining, levelling and pendulum units. Abasic knowledge of Windows® is required in order to work with the WinALC. The instructions on the WinALC programme do not contain any Windows® descriptions. The WinALC program carries out the following tasks: 1. When the track geometry is known: a) Input of target geometry data - Automatic calculation and output of the required target values for the lining and levelling system, including superelevation values. b) Input or acceptance of correction values from track surveying. - These values can be loaded in working mode together with target geometry data. In this way, track geometry is corrected in the precision method ©) (OPTION) Use of the curve laser in connection with target geometry values. - In this case deviations in alignment and level are measured during working mode and transferred to the measuring system. 2. When the track geometry is not known: Recording of the relative track geometry. - Automatic compensation calculation and subsequent output of the resulting target values for the lining and levelling system, including superelevation values. 3. (OPTION) Laser measuring run: - Recording of lifting and slewing values by laser measurement NEW FEATURE The computer is linked OPTIONALLY via the Ethemet interface to the DRP recording unit. English Plasserz Theure! SDG-7_1_10 5 2 Operating instructions for the all-in-one computer 2.1 Operating controls Function keys and status display Various operating controls are mounted on the right-hand side of the all-in-one computer frame. Description in order from top to bottom: - Button for switching the computer on and off. - Power LED: Green light shows that PC is switched on - HD LED: Yellow light indicates read or write access to hard disk. - Option to adjust screen brightness. - _ Interface cover for the USB port. English - [Passer « Theurer] 6 SDG-7_1_10 ERS 2.2 Keyboard CAUTION: As is common practice for the use of computers, the devices should be operated with clean hands (fingers). Working on the touch pad with greasy / oily fingers can cause lasting damage! 0@ 3 6 4) 8 9 10X11) C2013 14) ISMENTI8) 19) 0) 1 Esckey 13 Altkey 2 Keyboard template (function keys) 14 Space keys 3 Function keys F1 to F12 45 AltGrkey 4 Pos1/PrtScr Taste 16 FNkey 5 End /pause key 17 INS key 6 Numeral keys 48 DEL key 7 Backspace key 49 Control keys 8 Tabulator key 20 ENTER key 9 CAPS LOCK key 21 Directional keys 10 SHIFT key 22 Left mouse button 14° Ctrl key 23 Right mouse button 12. Windows key for start and context 24 Mouse table (touch pad) function English SDG-7_1_10 ‘peor Sennanabhiner GeBieTa ND 2.2.1 Description of the keys: Esc (escape, exit) closes an opened menu window. Tabulator activates the next selection / input box. CAPS LOCK key locks the SHIFT key. (capitals instead of small letters or special characters instead of digits). If the key has been activated, the LOCK LED is lit. Caution: For entering the password or digits the CAPS LOCK key should not be active. A message is shown. Hit the shift key or hit the CAPS LOCK key once again to switch to small letters (LED goes off). SHIFT key shifts to capital letters. Windows key opens the start bar. When pressed together with the FN key it opens the context menu. Ctrl, Alt, AltGr (Control, Alternative, Altemative Graphics) System keys for various combinations, see menu selection (Control, Alternative, Alternative Graphics). ‘Space keys inserts a space between two characters. For data input: selection of side of curve, superelevation, gradient, front offset and lifting FN key executes commands from the multi-function keys (in frame). For further functions see "Windows key" INS (insert) inserts the selected element. DEL (delete) deletes the selected element. Directional keys shifts the positioning line in graphic mode: to the left/right = in 1m intervals, Ctrl and |.h./r.h. = in 10m intervals, up/down by 10% of the set scale. Enter key to confirm inputs via keyboard or pre-selected menu selection. Page 1 moves the screen display up Page t moves the screen display down Back deletes the character last entered. Pos 4 and PrtScr (Position 1 and Print) In data input target geometry, you can change from alignment and superelevation input to longitudinal level input using the modifier key Alt. Together with the keys FN and Ctrl or Alt, the screen view or the program view is selected. This can be transferred to a Word file using the shift key + Ins, End and pause Change from longitudinal level input fo alignment and superelevation input using the modifier key Alt. Pause has no function. English 8 SDG-7_1_10 arrion Banbarsscinen Coming BT 2.2.2 Function keys Function keys are used to perform the various program functions. The template supplied together with the system shows in its left-hand top corner the ranges of use and in the corresponding row the symbols assigned to the respective functions. Key __|Field of application [Action Fi opens the help texts Measuring run sets alignment reference points, such as start / end of curve, press to the other rail, etc. F2 Working mode turns off synchronisation buzzer Measuring run marks superelevation events F3 Working mode acknowledges the synchronisation point (starting from <10 m) Measuring run marks changes in gradient F4 Working mode acknowledges the synchronisation point (> 10 m) F5 | Editing sets a constant alignment area measurements Measuring run sets a constraint point Fo Data input inserts several lines Measuring run sets start / end of a constraint area Fz Data input copies the last line Measurement sets a synchronisation point F8 Data input inserts a line FQ |Datainput deletes the highlighted line | Editing ‘opens superelevation input Fig [measurements determines the line direction with the help of arrow Working mode keys F11_ |Ifafile has been changes between graphic and table display mode ‘opened zi Ifa file has been Fe looted connects both windows (graphic and table) 2.2.3 Key combination: “SHIFT” key and function key Key Field of application Action Shift+F 1 opens help files on the respective topic English SDG-7_1_10 Shift +F 2 ]Editing measurements | skips to the next alignment marker Shift+F 3 |Editing measurements | skips to the next superelevation marker Shift + F 4 | Editing measurements | skips to the next change-in-gradient marker Shift+F 5 |Editing measurements |sets a constant longitudinal level area Shift +F 6 | Editing measurements | skips to the next constraint point Shift + F 7 Shift +F 8 |Data input skips to the next synchronisation point Shift + F 9 Editing measurements | starts alignment calculation Shift + F 10 a +F _ |Working operation _| starls / prepares working mode Shift+F | Ifa file has been ‘opens the scale-setting table 12 opened 2.2.4 Key combination "Ctrl" and function key Key Field of application _| Action Shift + F 4 Shift + F 2 [Editing measurements __| back to previous alignment marker Shift +F 3 |Editing measurements _ | back to previous superelevation marker Shift +F 4 |Editing measurements _ | back to previous next change-in-gradient marker Shift +F 5 Shift +F 6 |Editing measurements _ | back to previous constraint point Shift + F 7 Shift + F 8 [Data input back to previous synchronisation point Shift + F 9 [Editing measurements _ | starts longitudinal level calculation nit +F [Editing measurements _| deletes target superelevation input Shift + F11 |Ifa file has been opened | opens file information Ifa file has been opened Alt+F 12 |and the graphic window |selects optimum display scale activated English 10 SDG-7_1_10 3 Turning the computer on / off. The computer can be put into operation only when a designated user name and the corresponding password are entered. The following groups are given a user authorisation: Authorisation User name Password 1. Operating crew user ale 2. Service personnel servicet 3. For factory settings Users logged in with the user name "user" cannot, among other things, modify the operating system or install additional programs! 3.1 Turning the computer on. Provide voltage supply to the computer and do not turn it off during operation. Put computer into operation using on/off button (power button). ‘The power button is used in the same way as for example the mains switch on modern desktop PCs with ATX power supply: short press ... switch on PC or shut down operating system and switch off PC. ong press ... ATX power supply is switched off (possible loss of data!) Warning! Do not strike any keys until the password prompt appears! After switching on, the power LED is lit continuously. The HD LED flashes irregularly. If malfunctions of the computer have appeared, the messages indicated on the screen during the start-up procedure have to be observed carefully. They allow conclusions to be drawn about the occurring errors (see ALC trouble shooting) Beep tones during the start-up procedure indicate possible errors. (1 short beep and Dos Prompt = booted without error). Further beep codes can be found in the corresponding technical literature. ‘As soon as the following dialogue window appears: - Enter the user name, if it is not pre-set. Capitalisation does not make any difference! = Enter the password. Upper and lower case must be observed! English SDG-7_1_10 1 All iw Smo Leff ale Windows Paige os) After the password has been entered, the operating system will be started up and subsequently the WinALC program will be opened automatically. The WinALC program window appears on the screen, Datei Beabeiten Aibeitsbetieb Ansicht Fenster 2 (i) a a Driicken Sie F1. um Hilfe zu erhalten. Important: To prevent damage to the software, the onboard computer power supply must not be interrupted before the computer has been shut down and turned off English 12 SDG-7_1_10 Plasser« Theurer Toran Sebastain Goel MDF. 3.2 Turning the computer off. Before turning the computer off, finish working mode, store and close all files, ‘The computer can be shut down by pressing the on/off button or open the following window by selecting "Start—- shut down" in the start bar. Confirm the selection of "shut down'with the "OK" key; the operating system will be shut down and the computer turned off automatically Ce ead are fous 4 Starting and closing programs Programs are started by selecting from the start menu or by double-click on [BEER the program icons on the desktop. To close a program, double-click on the Close (X) symbol in the name bar, hit the Alt + F4 keys or enter the Terminate command in the file menu of the corresponding program 4.1 A window or program does not respond If a program does not respond or a calculation procedure takes a longer time (> 1 min.), you are advised to carry out the individual steps mentioned below in the correct order to terminate the program successfully. 1. Close the respective application. Press the CTRL+ALT keys and keep them pressed, then briefly press the DEL key once. A window will open with the following text: "The task does not respond Then activate the [Terminate task key and the task will be terminated. English PlassersTheurer SDG-7_1_10 13 Coton bactaanancnee Gla 2. Restart "Windows": If the task still does not respond, terminate Windows in the usual way. If that is also not possible, press the following keys twice in succession: CTRL + ALT + DEL After restarting the program you can continue working Do not reload defective data files that have led to the program crash. Correct possibly existing faulty entries in the files. 5 Installation of additional programs No additional programs are allowed to be installed without consulting the manufacturer. 6 Electrical connections The connections are not accessible without dismantling the unit. They are limited to power supply, Ethernet and housing earth. 6.1 Power supply Power is supplied externally via (buffer) batteries (24 volt) that are charged through the machine system. As described in Section 9.1, the battery Renata 950 mA, lifespan 2% years, must be replaced in good time. 6.2 Welding work Before commencing welding work on the machine, it is necessary to shut down the ‘computer and then remove the fuse of the power supply. Please note: Defects that occur due to failure to observe these measures will not be covered by the warranty. Englich 14 SDG-7_1_10 cre braursecine ose 7 Recovery of the system For the all-in-one computer a USB memory stick will be supplied together with the machine for recovery of the system After a system recovery using "Recovery", all program functions will be available and operative again. Warning! The procedure described below will delete any programs, data and user files installed later on! For this reason, user files should periodically be saved externally, if possible. Procedure: * Plug in USB memory stick named RECOVERY USB STICK when the computer is switched on or off. © Start the computer. © The following information will appear on the screen. English SDG-7_1_10 15 pot vr BantaanasinenGasiaht t * After the "count down" is completed or after pressing the "enter" button, the boot procedure is started, * Then the "select" field will appear for application selection * Here the system recovery is already pre-selected. Actuate the "OK" button by using the "enter" key or the mouse function. + Awarning appears: * By pressing the "yes" button, the recovery program will commence. * The progress of the recovery procedure is now displayed in % by a blue bar and can take up to 20 minutes. Do not activate the keyboard and the touch pad during this procedure! * Atthe end the select field will appear again. * Using the mouse or the navigation keys, select the command "Restart computer" and confirm, + Remove the stick. +The computer will be shut down and re-started, Ex] After tho re-stan, answer the fasten rc eee ote: De now vein wtnah dn tat dscomtes || message shown here with "YES". ‘Sol der Computer jot: neu getartet werden? The computer will be re-booted. English 16 SDG-7_1_10 TEE ea a) oorvor Sripaanacien Gosek MDF All machine-related parameters in the WinALC service program must be checked and, if necessary, corrected before putting the machine into operation. To do this, proceed as described in Section 8. 7.1 Using the Anti-Virus Software A VIRUS SCANNER is also installed on the USB RECOVERY stick. If this option is selected, the integrated hard disks will be checked. Before use, the latest anti-virus software should be downloaded from the internet. These data are accessed automatically during the virus scan 7.2 Update of the anti-virus file: The virus scanner used is called ClamAV and can be used without licence fees. The anti-virus data base can be found on the stick in the directory antivir and consists of three parts 1. Byte code 2. Daily 3. Main Download these three files and copy them onto the stick into the directory antivir (replace files). These files will be used when you start scanning If viruses are found, a query appears, asking if you want to transfer the infected files to the USB stick (into directory antiviAquarantine) together with a warning that this means the system can no longer be used (if important system files are affected). English Eipvar Sebeoraesinn Con 17: 8 Update WinALC parameters erecta) Sclgeonetic | SyetriNaker | Mesuno/aukichKHA | Avtibeieb Alpenen | Veschrite | Matstbe Graf | Gratk | Fesbon Gra | Tabelen ‘Sprache: Parameter sicher /ader: | BRB 2 I Sprache des Bettiebssystems verwenden ‘Arsicht nach Datei Nou bev. Cnen P Grelikensichttinen I Labellenansich nen Sensiges J Menipunkte belle’ und rai’ zeigen Fenster in MaximalaBe Cusorin anderen Fenster iftven Erweiterte Warrmeléungen und Absragen JW Aktuole Werte bei Mauscursoin Grafik ausgeben I Bemerkurgstes (Infolin Fenstettiel anzcigen OK, Abbiechen Plug in the "Recovery" stick. In the program WinALC, under file— program settings— general and then savelload parameters select the load option (diskette icon with red arrow). Open the disk drive and the directory (_\MaschPar) containing the machine parameters and then actuate copy. The parameter files *.dat are updated. The parameter files of any other programs installed also have to be updated 9 Technical Information / status per 2014 Supply voltage: 24V DC CPU BOARD INTEL CORE2 DUO U7500 1,06 GHZ, 533 MHZ FSB (Front Side Bus) 2MB L2 CACHE, REALTEK ETHERNET CONTROLLER RTL8111C. CHIPSATZ 945GME, 2 SOCKETS FOR SO-DIMM DDR2 MODULE (MAX. EXTENSION IN TOTAL 3 GB) Main memory max. 3 GB Battery type Renata 950 mA, lifespan 2% years Ambient temperature Operation 0 .. 40°C Humidity: Operation10 to 85%, non-condensing English 18 SDG-7_1_10 nor vn Buetainen Goro Vibration Operation (continuous) 2 - 9 Hz: 1.75 mm amplitude / 9 - 200 Hz: 0.5 g Operation (occasionally) 2 - 9 Hz: 3.5 mm amplitude / 9 - 200 Hz: 1 g Protection class 1P31 on rear (only with CF card inserted) IP65 / NEMA 250 type 4X, protected at front against dust and spray water Warni Under no circumstances should the fastening screws of the cooling block be unscrewed. If this connection is destroyed, the PPC800 must be sent to the factory for repair. If it does happen that the screws (secured by a seal) are unscrewed, any warranty is rendered void. SOL (Smart Oplay Da WC TPEIN Une OUT Bate (Mos Prof Sehater Replacement of the battery: The lithium battery (3 V, 950 mAh) assures the buffer of the internal real time clock (RTC) as well as the individually stored BIOS settings and is located behind the black cover. The buffer service life of the battery is at least 2% years (at 50°C, 8.5 pA of the components to be supplied and a self-discharge of 40%) The battery is a wearing part and should be replaced regularly (at the latest after the given lifespan). English (JERS rats SDG-7_1_10 19 pot vorSeheacnsannen Golo Error description In the event of a malfunction of the ALC system and before a Plasser & Theurer service department is notified, please provide the following information. Customer! Operating firm: Name: Telephone: E-mail Machine number: Year of construction: ALC serial number: Version number of the ALC program: Which error or which malfunction of the ALC or the measuring systems has been recognised? ‘When and how often does the error occur? Condition of the LED indicators before and/or during the error? Which error message is indicated on the display? Conditions at the time of breakdown or occurrence of the error? (temperature, mechanical stress, etc.) Have any modifications been carried out in the BIOS set up, the operating system or programs installed before the failure occurred? Have programs been installed or uninstalled? Precise description of the error: English

You might also like