Professional Documents
Culture Documents
76
and transmitting the data to a mobile phone via Bluetooth. The Algorithm 1: Swallow Detection Algorithm
hardware is powered by a lightweight lithium-polymer battery.
Smooth(Data);
The necklace is available in several varieties including a
for i = 1:Window:Size(Data) do
sportsband suitable for athletes and other active individuals, avg = CalculateAverage(Data[i]:Data[i+Window]);
and another targeted towards a more fashion-conscious au- for j = i:i+Window do
dience. Because the hardware components of the necklace diff = abs(avg - Data[i])
are very compact and lightweight, they can be embedded if diff < threshold then
in several different formfactors. One such design is shown diff = 0;
in Figure 2. Because the piezoelectric sensor generates a else
voltage in response to physical strain, tightening the necklace data[i] = diff;
excessively such that motion is restricted has a negative effect
on sensor accuracy; the necklace is designed to be worn for i = 1:Size(Data) do
loosely and comfortably, but sufficiently tight such that the if Data[i] > 0 then
sensor remains in contact with the skin. SwCount++;
i = i + Jump;
B. Microcontroller Board
The recently released RFDuino board samples the voltage
C. Android Application
77
Fig. 5. This figure shows the standard deviation of vibration sensor data
between swallows, for both solid and liquid foods. This heuristic is critical
for classification between these two food types, as the disturbance caused by
chewing is not present in the liquid waveform.
78
TABLE I
S WALLOW C OUNT VS . P ORTION S IZE
79
with the primary goal of making individuals more aware of
their eating habits, which we believe is critical for weight loss.
R EFERENCES
[1] K. Dorman, M. Yahyanejad, A. Nahapetian, M.-k. Suh, M. Sarrafzadeh,
W. McCarthy, and W. Kaiser, “Nutrition monitor: A food purchase
and consumption monitoring mobile system,” in Mobile Computing,
Applications, and Services, T. Phan, R. Montanari, and P. Zerfos, Eds.
Springer Berlin Heidelberg, 2010, vol. 35, pp. 1–11.
[2] (2012) Centers for disease control and prevention. an-
nualmedical spending attributable to obesity: Payer-and
Fig. 9. This figure shows the impact of necklace tightness on the clarity of service-specific estimates. w822.full.pdf. [Online]. Available:
the signal. http://www.cdc.gov/obesity/data/adult.html
[3] E. Stellar and E. E. Shrager, “Chews and swallows and the microstruc-
ture of eating,” Am. J. Clin. Nutr., vol. 42, no. 5 Suppl, pp. 973–982,
Nov 1985.
[4] P. S. Freedson, E. Melanson, and J. Sirard, “Calibration of the Computer
Science and Applications, Inc. accelerometer,” Med Sci Sports Exerc,
vol. 30, no. 5, pp. 777–781, May 1998.
[5] P. S. Freedson, K. Lyden, S. Kozey-Keadle, and J. Staudenmayer,
“Evaluation of artificial neural network algorithms for predicting METs
and activity type from accelerometer data: validation on an independent
sample,” J. Appl. Physiol., vol. 111, no. 6, pp. 1804–1812, Dec 2011.
[6] S. Patel, H. Park, P. Bonato, L. Chan, and M. Rodgers, “A review of
wearable sensors and systems with application in rehabilitation,” Journal
of NeuroEngineering and Rehabilitation, vol. 9, no. 1, p. 21, 2012.
[7] C. H. Horst, G. L. Obermann-De Boer, and D. Kromhout, “Validity of
the 24-hour recall method in infancy: the Leiden Pre-School Children
Study,” Int J Epidemiol, vol. 17, no. 1, pp. 217–221, Mar 1988.
[8] L. E. Burke, M. Warziski, T. Starrett, J. Choo, E. Music, S. Sereika,
S. Stark, and M. A. Sevick, “Self-monitoring dietary intake: current and
future practices,” J Ren Nutr, vol. 15, no. 3, pp. 281–290, Jul 2005.
Fig. 10. This figure shows the representative signal of various movements [9] Y. Dong, J. Scisco, M. Wilson, E. Muth, and A. Hoover, “Detecting
not associated with ingestion. Periods of Eating During Free Living by Tracking Wrist Motion,” IEEE
J Biomed Health Inform, Sep 2013.
[10] E. S. Sazonov, O. Makeyev, S. Schuckers, P. Lopez-Meyer, E. L.
Melanson, and M. R. Neuman, “Automatic detection of swallowing
detected as swallows, while approximately 15% of abrupt events by acoustical means for applications of monitoring of ingestive
vertical head movements were detected as swallows. behavior,” IEEE Trans Biomed Eng, vol. 57, no. 3, pp. 626–633, Mar
2010.
[11] Y. Ma, B. C. Olendzki, S. L. Pagoto, T. G. Hurley, R. P. Magner, I. S.
VIII. F UTURE W ORK Ockene, K. L. Schneider, P. A. Merriam, and J. R. Hebert, “Number of
Though the system attempts to identify the volume of food 24-hour diet recalls needed to estimate energy intake,” Ann Epidemiol,
vol. 19, no. 8, pp. 553–559, Aug 2009.
consumption and make users more aware of their eating habits, [12] O. Amft, M. Kusserow, and G. Troster, “Bite weight prediction from
the next logical step is to extend the classification of food acoustic recognition of chewing.” IEEE Trans. Biomed. Engineering,
types into several broad categories. This may require supple- vol. 56, no. 6, pp. 1663–1672, 2009. [Online]. Available: http://dblp.uni-
trier.de/db/journals/tbe/tbe56.html
menting the hardware with additional sensors such as a small [13] H. Tsujimura, H. Okazaki, M. Yamashita, H. Doi, and M. Matsumura,
microphone. Another potential improvement is to extend the “Non-Restrictive Measurement of Swallowing Frequency Using a Throat
system with fully real-time functionality. In the current system, Microphone,” IEEJ Transactions on Electronics, Information and Sys-
tems, vol. 130, pp. 376–382, 2010.
data is transmitted from the necklace in real-time, and instant [14] M. Aboofazeli and Z. Moussavi, “Automated classification of swallow-
feedback is given to the user when a swallow is detected. ing and breadth sounds,” Conf Proc IEEE Eng Med Biol Soc, vol. 5, pp.
However, the more advanced classification algorithms which 3816–3819, 2004.
[15] J. Cheng, O. Amft, and P. Lukowicz, “Active capacitive sensing:
distinguish between different food types are implemented Exploring a new wearable sensing modality for activity recognition,”
offline. in Proceedings of the 8th International Conference on Pervasive
Computing, ser. Pervasive’10. Berlin, Heidelberg: Springer-Verlag,
IX. C ONCLUSION 2010, pp. 319–336. [Online]. Available: http://dx.doi.org/10.1007/978-
3-642-12654-319
In this paper, we describe a low-cost, wearable sensor sys- [16] O. Amft and G. Troster, “Methods for detection and classification of
normal swallowing from muscle activation and sound,” in Pervasive
tem in the form of a necklace with an embedded piezoelectric Health Conference and Workshops, 2006, Nov 2006, pp. 1–10.
sensor. The necklace is capable of estimating volume of food [17] R. D. Mattes and W. W. Campbell, “Effects of food form and timing
consumption and transmitting the data to a mobile phone for of ingestion on appetite and energy intake in lean young adults and
in young adults with obesity,” J Am Diet Assoc, vol. 109, no. 3, pp.
analysis. The system was able to detect 85.3% of potato chip 430–437, Mar 2009.
swallows, 84.5% of sandwich swallows, and 81.4% of water [18] R. Thompson, “Preventing cancer: the role of food, nutrition and
swallows. Furthermore, the system is capable of identifying physical activity,” J Fam Health Care, vol. 20, no. 3, pp. 100–102,
2010.
solid and liquid foods with an average F-measure of 86%.
The system and software described in this paper were designed
80