Professional Documents
Culture Documents
10/10/2019 10:46:57 AM
SIGNAGE A2.2 - GENERAL NOTES
SN1 MEN'S RESTROOM (REFERENCE A6.0)
SN2 WOMEN'S RESTROOM (REFERENCE A6.0) 1. OSB IS NOT AN APPROVED CONSTRUCTION MATERIAL AND SHALL NOT BE SUBSTITUTED FOR FIRE TREATED
1/2" GYP. BD. (PAINTED 1/2" GYP. BD. ATTACHED SN3 EMPLOYEES ONLY PLYWOOD.
REF W/ 1" TYPE 'S' SCREWS @ SN4 THIS DOOR IS TO REMAIN UNLOCKED WHEN BUILDING IS 2. ALWAYS WATERPROOF DEMISING WALLS IN WET AREAS, INCLUDING BEHIND COOLER/ FREEZER AND BEVERAGE 502 SW A STREET, SUITE 2
INTERIOR ELEVATIONS) 8" O.C. ALONG EDGES, @ OCCUPIED. (NOTE: THE SIGN SHALL BE IN LETTERS 1 INCH COUNTER. BENTONVILLE, AR 72712
ATTACHED W/ 1" TYPE 'S' 12" O.C. IN THE FIELD OF HIGH ON A CONTRASTING BACKGROUND.) 3. ALL SUBSTRATES ARE TO EXTEND TO DECK, UNLESS NOTED OTHERWISE. WWW.BATESFORUM.COM
SCREWS @ 8" O.C. ALONG THE BOARD. JOINTS TEL: 479.633.8165
SN5 EXIT TACTILE SIGN PER LOCAL BUILDING CODE 4. ALL WALL FINISHES IN THE MERCHANDISE / SALES AREAS SHALL BE FRP WALL PANEL "FRP-A" UNLESS NOTED
EDGES, @ 12" O.C. IN THE ORIENTED VERTICALLY OTHERWISE ON THE FLOOR PLAN. (REFERENCE MATERIALS SCHEDULE).
FIELD OF THE BOARD. AND STAGGERED ON
JOINTS ORIENTED OPPOSITE SIDES OF 5. PROVIDE FULL HEIGHT CORNER GUARDS AND "T" MOLDING AS REQUIRED AT ALL OUTSIDE CORNERS AND PANEL
Copyright 2019 FS Architecture, P.C.
JOINTS. CORNER GUARDS SHOULD BE FOR MATERIAL FINISH SPECIFIED IN FINISH AND MATERIAL SCHEDULES.
E VERTICALLY AND
STAGGERED ON OPPOSITE
ASSEMBLY TO BOTTOM
OF ROOF DECK. 6. ALL INTERIOR FACE OF EXTERIOR SIP PANEL WALLS TO BE COVERED WITH 1/2" GYPSUM BOARD FROM FLOOR TO
E Drawings and Specifications as instruments of service are and shall remain
the property of the Architect. They are not to be used on other projects or
SIDES OF ASSEMBLY TO ROOF DECK TO MEET FLAME SPREAD RATING. ATTACHED W/ 1" TYPE 'S' SCREWS @ 8" O.C. ALONG EDGES, @ 12" extensions to this project except by agreement in writing and with
BOTTOM OF ROOF DECK. O.C. IN THE FIELD OF THE BOARD. JOINTS ORIENTED VERTICALLY AND STAGGERED ON OPPOSITE SIDES OF appropriate compensation to the Architect.
ASSEMBLY TO BOTTOM OF ROOF DECK. Contractor is responsible for confirming and correlating dimensions at job
site; the Architect will not be responsible for construction means, methods,
T-5 (REF MATERIAL T-2 (REF MATERIAL 7. **ALL SUBSTRATES ARE TO BE APPLIED OVER AND IN ADDITION TO THE WALLBOARD REQUIRED FOR FIRE RATED techniques, sequences or procedures, or for safety precautions and
SCHEDULE) ADHERE PER SCHEDULE) ADHERE PER WALL CONSTRUCTION DESCRIBED ON THIS SHEET.** programs in connection with the project.
MANUFACTURERS MANUFACTURERS
CLG HT.
RECOMMENDATIONS RECOMMENDATIONS STORE #:
41140
10'-0"
9'-4"
1" TYPE 'S' SCREWS @ 16"
O.C. ALONG EDGES & IN
THE FIELD OF THE FRP-1 (REF MATERIAL 1/2" MOISTURE RESISTANT
BOARD. JOINTED 1/2" MOISTURE SCHEDULE) ADHERE PER GREEN GYP BD TENANT
ORIENTED VERTICALLY RESISTANT GREEN GYP MANUFACTURERS ATTACHED TO METAL 7-
AND STAGGERED ON BD ADHERED TO COOLER RECOMMENDATIONS STUDS W/ 1-1/4" HOT
OPPOSITE SIDES OF VAULT. STAPLE DIPPED GALVANIZED
ASSEMBLY TO BOTTOM PERIMETER AT 12" O.C. SCREWS @ 8" O.C. MEP CONSULTANT
OF ROOF DECK. ANDREW D. FINNEGAN, P.E.
502 SW A STREET, SUITE 2
BENTONVILLE, AR 72712
B-2 - REF: A6.1 FOR B-1 - REF: A6.1 FOR
MATERIALS SCHEDULE B-2 - REF: A6.1 FOR
MATERIALS SCHEDULE MATERIALS SCHEDULE STRUCTURAL CONSULTANT
SELECT STRUCTURAL
12573 NEW BRITTANY BLVD.
FORT MYERS, FL 33907
PLY IBU ONLY @ COOLER VAULT FRC ONLY @ COOLER VAULT ILM CONTACT:SHAWN ANDERSON
PROTO:02/28/2019
D D
11
_____________________________________________________________
A7.0
1/2" GYP. BD. (PAINTED
REF
INTERIOR ELEVATIONS)
ATTACHED W/ 1" TYPE 'S' B
SCREWS @ 8" O.C. ALONG
EDGES, @ 12" O.C. IN THE
IBG
FIELD OF THE BOARD. ICB ILM
JOINTS ORIENTED
VERTICALLY AND 15' - 2 1/2"
SN5
7-ELEVEN STORE
CONCORD, NC 28027
310 CODDLE MARKET
STAGGERED ON OPPOSITE
CROSLAND SOUTHEAST
SIDES OF ASSEMBLY TO
BOTTOM OF ROOF DECK. IBG
PAINT ABOVE & AROUND SN2 SN1
CHARLOTTE, NC 28202
T-1 (REF MATERIAL
SCHEDULE) ADHERE PER INTERIOR ELEVATIONS)
BEER 1
FULL HT.
MANUFACTURERS
CLG HT.
RECOMMENDATIONS CAVE
SN3
110 IBG
ILM
IBG IBG
AT RESTROOMS &
IBG PNT
HALLWAY
PLY
MERCHANDISE
101 SALES ELECTRICAL
COOLER 102 107
VAULT SN3
IBU
109
1/2" GYP. BD. (PAINTED REF
B INTERIOR ELEVATIONS) B
FOR BID ONLY
ATTACHED W/ 1" TYPE 'S'
BIM 360://41140 (BF0104567) 7-11 Concord, NC @ George Liles (19022)/Concord NC_A_R16.rvt
ICE OFFICE
10'-0"
A B-1 - REF: A6.1 FOR B-2 - REF: A6.1 FOR A PROJECT NUMBER: 19022
MATERIALS SCHEDULE MATERIALS SCHEDULE
RELEASE DATE: 08/12/2019
2 SUBSTRATE AND WALL FINISH TYPES (NOT ALL WALL TYPES MAY BE USED) 1 WALL SUBSTRATE & WALL FINISH PLAN
A2.2 1" = 1'-0" A2.2 1/4" = 1'-0"
A2.2
N
6 5 4 3 2 1