You are on page 1of 4
NSLS = Roll-in rack Tunnel Blast Freezers Mod. BURAN (€EE GENARAL CHARACTERISTICS: ‘© Working temperature : down to -38°C ‘© Structure : completely dismountable with modular self-bearing sandwich panels, isolated with injected rigid high density ( Kg/m? 43 ) expanded polyurethane of ‘mm.100 thickness. '* Pressure foamed corners with a radius of 15 mm which form a hygienic seal on the inside that is easy to clean, in conformity with European regulations. Internal stainless steel bumpers and air convection system. Internal panel coating : Alsi 304 stainless steel External panel coating : Pre-painted galvanized stee! sheet Equalizing Valve Doors : hinged, mounted directly on a suitably reinforced sanel. Characteristic : One-latch heavy duty lock with key and safety release ~ Stainless steel frame ~ Equipped with silicon gaskets Industrial adjustable hinges ~_Anti-condensation heating cable Heavy duty stainless stec! entry ramps © Floor : 100mm isolated panel Reinforced with a 10mm ST Phenolic Stratified laminate ‘with orange peel surface finish, R10 anti- Capacities: Evenly distributed static load 4500 Kg/m2 ; Concentrated load: 800 Ke/50cm2 Maximum dynamic load on 1 rubber wheel with a minimum contact surface of 3 cm2 240 Kg. ‘© Aluminium and copper air-evaporators of our design with high efficiency ver 8-10mm. fin spacing (less possibilty of ice formation ) Ventilator speed : 1400 rotations/min; 3-4 ventilators Ebm/Zlehl Proportionalised thermostatic valve. Defrosting by means of hot gas Coil - Housing The coil, made of aluminium fins and copper tube. This model has 350 mm fan diameter with 10mm fin specing. The coils are tested with nitrogen atappressure of 25 bar. The housing is made of aluminium and stainless steel Fon motore The fan motor models in use have the following features: with internal thermal protection - power supply 230-240V/1/50-60Hz = IPS protection rate electrics made in conformity with 73/23 CEE Law Tension directive 2irtech #éirtech *TROPICALIZED CONDENSING UNIT without housing, composed of BBITZER Semi-hermetic compressor supplied with shut off valves and crankcase heater Single stage compressor when operating with gas R404a = Two stage compressor when operating with gas R448a or R449a Power : 400/SOhz/3ph with Built-in Electrical Panel Modular screwed frame galvanized and painted with epoxy-powder. Equipped with height- adjustable shock absorbing feet. Built-in air-cooled tropicalized condenser equipped with four pole fan motors Liquid receiver Liquid separator Suction filter Flare connected drier fiter *Sight-glass High pressure switch with fixed setting and automatic reset Solenoid valve on the liquid line -Nitrogen-pressurised condensing unit Double safety pressure switch Fan capacity pressure switch Check Valve PED category 2 PROFESIONAL SYSTEM FASTCOLD: Professional LCD system for the control of quick deep- freezing and consequent preservation by means of electronic device, which enables the following applications = = Blast chilling down to +3°C ( core temperature ) with core pin-probe ~ Shock freezing down to -18°C ( core temperature ) with core pir-probe - Lowering cycle with programmable duration/temperature - Alarm function with acoustic signal in case of problems - Manual and automatic defrosting cycles ~ HACCP = USB recorder ( optional ) ‘© Maximum rack height mm. 1980 *irtech “SLL #éirtech Racks em, 6x62 Racks cm, 56x72 Racks cm. 66x82 Racks. 6x102 Racks cm. 6x102 Traysem. 60x40 Traysem. 5070 ‘Traysem. 60x80 Traysem. 601100 Traysem. 80100 BURAN 266, 3 3 2 a - BURAN 368 6 a 5 2 2 BURAN 468 7 6 4 3 eee oie surance tah resavuce MRINUSS ssaaczimy renanceh — soammhy ot pay seem surance {0070/30h isan SURANMIEE is sasxztah —ToxSExiGh —eoonit) AIS (t3) a nates) mate svnwn ines {00/0/20 aserwnase SUANEISS acsyznxztsn 7849641860 eoamOnI) oe) vais) mate ate ‘o0/020h seorizss ANE sessansx2em —Texisoxsoh soon) «satya woineey nee seam sunaNss “0070/30 warns SUMAN MESS ess op 26h Tax1800:96) sonMIH(2) ast) HN fits i2) fate suaan aes “00/0398 ISBRNH268 racks 60x80 '163X203x243h «78x 180x:96h _80x200h (2) 300° kW 29 (Hp 23) RAO4a tvantibac) has 400/50/3ph raomisss UNE seseamsxztn —exz00x39hn sonia) © ota) ota Siz ie) ate sean SURANSES {0270/0h tga AIMANVSEE, —13ya031250h Tox2600:96 soon) «AS D8) ma tat bao) pate sunan oes ah repmuiace YTAVEHE —seaxsonn23eh —78n280x:86h abatohe) ASO" =D pH) fwv27 as) pate surance 400/0/0h seomuiss “UALASE sess sesna8m) Texan) sommmhia) BOF Me) nt wees es ssoan surance 40070398 Isom ALRANMESS a assxzash —ToxxEOn:S6h sO) «—««goo*S twins) te kw 33 (Hp 30) Rega * capacity calculated on the basis of a 90 minutes freezing cycle of par-baked baguettes gr. 100-600 2irtech NSLS #éirtech Racks cm. 46x62 Racks em. 56472 Racks cm. 66x62 Racks em. 66x102 Racks em. 861102 Trays cm. 60340 Traysem. 5070 ‘Wraysen.60x80 —Traysen. 603100 Traysem. 80x100 ‘BuRAW 1810 2 2 1 1 1 ‘BURAN 2810 a 2 3 2 2 ‘BURAN 3810 6 5 4 a 2 ‘BURAN 4810 ° 7 6 4 a 180RN una iie0 .——_40/50/26n BERN URAL. sas 2th 8 1HBxB6h 9520412) 0 (ose paote 400/50/30h bunan wsio ean feani4ax20h —n18x196h —_s5a00H(2) 20 =H TB( Mp9) toda ei Trek Bodo Wwe) asa ‘00/50/0h uran H1s10 ann SURANHISIO. as aaczash 93x18 x186h _s5zo0h(2) aso Heinp a) ROAR 16 kW 9(Hps) ea 188RN BURA 12810 By an a 7 wate BORN BURAN2D ses yaqsnatsh sa xz20ni56h —orzooniy) sot nN aay kW9(Hp8) naasa sen uma esi0 0/80/35 XBBRN —BURANMZEIO aay yogsy2tth —s8x220x1960 s200n12) ase USONBPM, aay kw ib(Hpiz) R4488 4o0/sfseh BORN BURANHEIO as zeszash —sazzoaiseh ssao0h(2) «seo awa) moka fovai ips) hasta s00/30/39h eam GURANLAEIO. sas saaxzush as xae0xis6h —s500h(2) sot wae) moka kW 21 (Hpi) RA48a sen suean masi0 .00/0/h BBERN BURANMEEIO” agp s4sy248h 53x320x196n 951200012) 75+ UENBTN,pagay kW 24 (Hp 20) RA48a «00/5/30 18BRN—BURANVEIO sas saazash 95x520%186h s5200h(2) «SOYA (np ae) moda kw 2r\ip2s) ata 4o0ysrapn ABBR BURAN IASI 183443x243h —-93.x420x196h _95x200h (2) 450° kwa2(Hp 34) RAO4a UaBi0 rcs 8x00 ‘ kW 27 (Hp 2s) RA48a {00/5/30 ABBRN —BURANMAS10 a3 ¢4q3x243h —«93.X420X196M —_95X20OH (2) 600" kw 48 (Hp 44) Raoda masio 4 racks 80x100 kw 33 (Hp30) Rada * capacity calculated on the basis of a 90 minutes freezing cycle of par-baked baguettes gr. 100-600 2irtech

You might also like