You are on page 1of 12
RT TE TE ET rv THE INDUSTRIAL DEVELOPMENT & TESTING LABORATORY <2 = Govt. Regd. No. NSIC/SL/GP/RS/REGN/WB/T-O11/11 I NABL ACCREDITED MAKARDAH ROAD, SHANPUR (CHATTERJEE SHED) DASNAGAR, HOWRAH - 711 105 Certificate No. TC-5240 TEST REPORT TIDL/TEST/04 Page No.: 10F1 Test Report No. : ULR-TC524020100002829P Date; 1/03/2020 Customer's Name & Address : Mls. Teshi Engineers & Sales Promoters (P) Ltd. '40, Strand Road, Ground Floor, Room No-34, Kolkata-700001 ‘Customer Ref. Dated : 06/03/2020 01 No Sample for Chemical, Mechanical, IGC and Microstructure Test Heat No : F 721165, Description of Sample : Item: 1 No. cut piece of fiting made from 1" Sch. 408 pipe (3. 38mm thick). ‘Mechanical Test Witnessed By Mr. Segnik Nayak of TUV India Pvt. Ltd Meena and IGC Test Witnessed By Mr. A Sethi of Teshi Engineers & Sales Promoters (P) a it ‘Sample received on:- 06/03/2020 Environmental Condition : Ambient Samp rece one 1310372020 The tests marked with an * are not accredited by NABL This ie to certify that the above sample (s) has been tested with the following results Type of Test (CHEMICAL FINDINGS REQUIRED VALUES OF. ‘ASTM-A-403-2001, Grade-WP304L “Carbon % o.02 0.03 max te Manganese % 1.30 2.00 max 5 SiGe siicon % 0.38 4.00 max = Sulphur % 016 0.030 max 3 LC¥g Phosphorus % 0.032 0.045 max 3 + Chromium % 18.40 18.00 to 20.00 ii ef Mossi 810 8.000 12.00 ‘2 Cl MECHANICAL z Eads 553:%Mpa 485 Mpa min YS 379 Mpa 170 Mpa min. 2 g % Elongation 33.33% 28,00 % min. S 3D; = | Antergranular Corrosion Test Practice-E 2 SUES J Sensiuzing Treatment done at 675°C for | hour 2 E 4g & Sample was boled in a Copper-Copper Sulphate 416% Sulphuric Acid test Solution for 24 hours. é © sample was taken out the solution after: 24 hours bolling washed with cold water, dried and flattened se per ASTM-A-370-2014 through 180" over a mandrel diameter equal tothe thickness of the specimen Observed : No fissure or crack were observed at 20X. ION AFTER IGC PRACTICE E: ie sample was etched out with 10 % Oxalic acid and observed in 100%. 500 Magn ication re Factbetructure of the sample shows austenitic grains with twin bands, Some Carbide Precipitation D4 has occured a grain poundones but no le grain is completely Surrounded by carbides. an ‘Spectfcation used - IS 228{ Part 1,2, 6, 9, 3,6, )1967, RA2014 & 2018 for Chemical Test, 1$-1608-(Part-1) 2016 for Mechanical Test, ASTM-A-262-2015 for IGC Test & 18: 7739(Part-4)-1975 & (Part-5)-1976, RA2007 for Microstrucures Test End of Report a PRS 7 \: er @ Dy. oul Manager Testing Laboratory ors Note : The test report shall not be reproduced, except in full, without written approval of the Laboratory ‘Sample (s) not drawn by us * tannin plate Result pertains to samples. For'The industli Ph, 2667-1938 (How), Mob, : 9836706349 / 9433378906, e-mail :g THE INDUSTRIAL DEVELOPMENT f TESTING LABORATORY Govt. Regd. No. NSIC/SL/GP/RS/REGN/WB/T-011/11 ex 4 NABL ACCREDITED ae? MAKARDAH ROAD, SHANPUR (CHATTERJEE SHED) 7S DASNAGAR, HOWRAH - 711 105 Ccaritiate No: 70-6240 TEST REPORT TIDL/TEST/04 Page No.: 10F 1 Test Report No. : ULR-T¢524020100002832P Date ; 1/03/2020 Customer's Name & Address : Mls. Teshi Engineers & Sales Promoters (P) Ltd. ® 6, Strand Road, Ground Floor, Room No-34, Kolkata-700001 Customer Ref. : Dated : 06/03/2020 ‘Type of Test 1 No Sample for Chemical, Mechanical, GC and Microstructure Test Heat No : F 695512 Desorption of Semple :___ltem: 1 No, cut plece of fiting made from 2-1/2" Sch. 40S pipe (6.16 mm thick) tion, of Sams Witnessed By Mir. Sagnik Nayak of TUV India Vt. Mecanca| and IGC Test Wilnessed By Mr. A Sethi of Tesh Engineers & See Promoters (P) Ltd Sample received on:~ 06/03/2020 Test Completed on:- 13/03/2020 ‘The tests marked with an * are not accredited by NABL ‘This is to certify that the above sample (s) has been tested with the following results c. Environmental Condition : Ambient CHEMICAL FINDINGS REQUIRED VALUES OF ‘ASTM-A-403-2001, Grade-WP3041. ‘1 L *carbon % 0.02 0.03 max a Manganese % 1.53 2,00 max iS Silicon % 033 4.00 max E 3 ‘Sulphur % 0.021 0.030 max = Phosphorus % 0.018 0.045 max 3 bg Chromium % 18.51 18.00 to 20.00 iS 3 Nickel % 8.54 8,00 to 12.00 « (ete MECHANICAL Fag TS. 526 Mpa 485 Mpa min 24 ¥.5. 392 Mpa 170 Mpa min 88 Elongation 40.83% 28.00% min “Intergranular Corrosion Test Practice-E ‘Sensitizing Treatment done at 675°C for 1 hour. Sample was boiled in @ Copper-Copper Sulphate 16% Sulphuric ‘Acid test Solution for 24 hours. Serle was taken out the solution after 24 hours boing washed with cold water, dried and flattened Se per ASTM-A-370-2014 through 180° over a mandrel ameter ‘equal to the thickness of the specimen. Obeorved : No fissure or crack were observed at 20X- ooo STRUCTURE EXAMINATION AFTER ISC PRACTICE E: i ree rs etched outwith 10% Oral acid and observed in 1007, S208 Magnification >” as occurred at grain boundories but no single grein 6. ‘completely Surrounded by carbides. This! Thisis T ample (8) not drawn by us * TAPEraIOnY oigdetor si Result pertains to samples For The Industrial ‘he Microstructure of the sample shows austenitic grains ‘with twin bands, Some Carbide Precipitation ‘Specification used - 1S : 228 Part- 1, 2, 8, 9, 3,6, 5)1987, RA2014 & "2018 for Chemical Test, 18:1608-(Part-1) 2018 for Mechanical Test, "ASTM-A-262-2015 for IGC Test & 1S. 7730{Part-1)-1978 & (Part-5)-1976, RA2007 for Microstrucyrss Test End of Report. iS A YaGoReok ek fs) © CeXen prod ‘Manager i Apa " §} sting Laboratory arabe ow Mob 7 9896706049 /SHTGRTSBOS, emai hose WORDU Iara boatow@aral.com S ae Note 7 The test report shall not be reproduced, except in full, without written approval of the Laboratory THE INDUSTRIAL DEVELOPMENT & TESTING LABORATORY Govt, Regd. No. NSIC/SL/GP/RS/REGN/WB/T-O11/11 A NABL ACCREDITED MAKARDAH ROAD, SHANPUR (CHATTERJEE SHED) DASNAGAR, HOWRAH - 711 105 Certificate No. : TC-5240 TEST REPORT TIDL/TEST/04 Page No.: 10F 14 Test Report No. : ULR-T0524020100002830P Date: 13/08/2020 Customer's Name & Address : Mis. Teshl Engineers & Sales Promoters (F) Ltd. “40, Strand Road, Ground Floor, Room No-34, Kolkata-70000% Customer Ref. : Dated : 06/03/2020 Type of Test 01 No Sample for Chemical, Mechanical, IGC and Microstructure Test Heat No : F 723658 Description ot Sample : __liem: 1 No. cut place of Hing made from 1-1/2" Sch. 405 pipe (3.68mm thick), ton eal est Witnessed By Mtr. Sagnik Nayak of TUV Incie Pvt. Ltd Mecha red IGC Test Witnessed By Mr. A Seth of Teshl Engineers & Sales Proves (PyLta nbient Sample received on:- 06/03/2020 Test Completed on:- 13/03/2020 Environmental Conditior c : ‘The tests marked with an * are not accredited by NABL ‘This is te cerity that the above sample (s) has been tested with the following results CHEMICAL EINDINGS REQUIRED VALUES OF ASTM-A-403-2001, Grade-WP304L 2 carbon % o.02 (0.03 max _ Manganese % 133 2,00:max la gy Silicon % 037 4.00 max Be ‘Sulphur % 0.03 0.030 max 3 Phosphorus % 0.036 0.045 max s ‘Chromium % 18.51 18.00 to 20.00 38 Nickel % att 8.00 to 12.00 ga “MECHANICAL oo eee = eae 8, 516 Mpa 486 Mpa min ary ¥.8. 370 Mpa 470 Mpa min. = 3 Elongation 32.64% 28.00 % min gs Soe aetna nein et "a crltihas 33 Sensitizing Treatment done at 675°C for 1 hour. a 2 i Sample was boiled in a Copper-Copper Sulphate 16% ‘Sulphuric Acid test Solution for 24 hours. a ‘Sample was taken out the solution after 24 hours olling washed with cold water, dried and flattened as per ASTM-A-370-2014 through 180° over a mandrel diameter ‘equal to the thickness of the specimen. ‘Observed : No fissure or crack were observed at 20%. > ISRO STRUCTURE EXAMINATION AFTERIGG PRACTICES: \The sample was etched out with 40 % Oxalic acid and observed in 400X, 500X Magnification. «rhe Microstructure of the sample shows austenitic grains with twin bands, Some Carbide Precipitation re cosed at grain boundories but no single grain is completely Surrounded carbides. Secincaton used - IS: 228( Part 1, 2,8, 9, 3,6, 6)1987, RAZO1A B 20° for Chemical Test, Peec0s (Parte) 2018 for Mecharical Test, ASTM-A-262-2015 for IGC Test & I 7739(Pari-1)-1975 & (Part-6)-1876, RAZ007 for Microstrucpres Test End of Report . Sample (8) not drawn by us = tabeaton ese © TAs @) * Dv. cunt ane Result pertains to samples. For The Industrial esting Laboratory Ph, 12667-1938 (How), Mob, : 9836706349 / 9433373906, e-mail ahs S3/S9hn [heidi laboratory@gmail.com , Noto she test report shall not be reproduced, except in full, withdittwritten approval of the Laboratory 4 THE INDUSTRIAL DEVELOPMENT & TESTING LABORATORY ‘¢ Govt. Regd. No. NSIC/SL/GP/RS/REGN/WB/T-O11/11 NABL ACCREDITED MAKARDAH ROAD, SHANPUR (CHATTERJEE SHED) DASNAGAR, HOWRAH - 711 105 Certificate No. : TC-5240 TEST REPORT TIDL/TEST/04 Page No.: 10F 4 Test Report No. : ULR-TC524020100002834P Date ; 13/03/2020 Customer's Name & Address ; M/s. Teshi Engineers & Sales Promoters (P) Ltd. 40, Strand Road, Ground Floor, Room No-34, Kolkata-700001, Customer Ret. : Dated : 06/03/2020 ‘Type of Test : (01 No Sample for Chemical, Mechanical, IGC and Microstructure Test Heat No: F 724965 Description of Sample : Item :1 No cut piece of fitting made from 4" Sch. 40S pipe (6.02 mm thick) Mechanical Test Witnessed By Mr. Sagnik Nayak of TUV India Pvt. Ltd Mechanical and IC Test Witnessed 8y Mr. A Sethi of Teshi Engineers & Sales Promoters (P) Ltd a = heap ‘Sample received om:- 05/03/2020 Environmental Condition : Ambient Test Completed on:- 13/03/2020 The tests marked with an * are not accredited by NABL This is to certify that the above sample (s) has been tested with the following results CHEMICAL, FINDINGS REQUIRED VALUES OF ASTM-A-403-2001, Grade-WP304L *Carbon % 0.02 0.03 max 4 Manganese % ant 2.00 max Silicon % 0.41 1.00 max Sulphur % 0.012 0.030 max ered By ie Phosphorus % 0.029 0.045 max 23 Chromium % 18.82 18.00 to 20.00 s Nickel % 8.24 8.00 to 12.00 as MECHANICAL so TS. 553 Mpa 485 Mpa min ao hy. 419 Mpa 170 Mpa min. b= # Elongation 37.12% 28.00 % min. 28 “intergranular ice-E 3s Sensitizing Treatment done at 675°C for 1 hour. 2? } Sample was boiled in a Copper-Copper Sulphate 16% Sulphuric Acid test Solution for 24 hours. ‘22 3 Sample was taken out the solution after 24 hours bolling washed with cold water, dried and flattened eT 288 per ASTM-A-370-2014 through 180° over a mandrel diameter equal to the thickness of the specimen Observed : No fissure or crack were observed at 20X.. MICRO STRUCTURE EXAMINATION AFTER IGC PRACTICE E The sample was etched out with 10 % Oxalic acid and observed in 100X, S00X Magnification ‘The Microstructure ofthe sample shows austenitic grains with twin bands, Some Carbide Precipitation S55 ||» |has occurred at grain boundories but no single grain is completely Surrounded by carbides. SSRs Breciication used - IS: 228( Part- 1, 2, 8, 8,3, 6, 5)1887, RAZ014 & 2018 for Chemical Test 5 =X) 18:1608-(Pari-1) 2018 for Mechanical Test, ASTM-A-262-2015 for IGC Test & 7's: 7739(Part-1)-1975 & (Part-5)-1976, RAZ007 for Microstrugures Test End of Report # Laboratory pifector # Dy. cuasG Manager Sample (s) not drawn by us I, a ‘esting Laboratory Result pertains to samples. For The Industri Note : The test report shall not be reproduced, except in full, without written approval of the Laboratory RRR RET ET ET Tee d ( EE 6 THE INDUSTRIAL DEVELOPMENT & TESTING LABORATORY Govt. Regd. No. NSIC/SL/GP/RS/REGN/WB/T-O11/11 NABL ACCREDITED ax Be) MAKARDAH ROAD, SHANPUR (CHATTERJEE SHED) DASNAGAR, HOWRAH - 711 105 Certificate No. : TO-5240 TEST REPORT TIDL/TEST/04 Page No.: 10F 1. Test Report No. : ULR-TC524020100002835P Date; 19/03/2020 Customer's Name & Address : M/s. Teshl Engineers & Sales Promoters {P) Ltd. “40, Strand Road, Ground Floor, Room No-34, Kolkata-700001 ‘Customer Ref. Dated : 06/03/2020 Type of Test : ‘01 No Sample for Chemical, Mechanical, IGC and Microstructure Test Heat No : F 673482 Description of Sample : tem :1 No cut piece of iting made from 6" Sch. 405 pipe (7 44 mm thick) Mechanical Test Witnessed By Mr. Sagnik Nayak of TUY India Pvt. Lid Mechanical and IGC Test Witnessed By Mr. A Sethi of Teshi Engineers & Sas Promoters (P) Ltd, Environmental Condition : Ambient Sample received on: 06/03/2020 ~ 13/08/20 ‘The tests marked with an * are not accredited by Sauget mie ‘This ie to certty that the above sample (s) has been tested with the following results CHEMICAL FINDINGS REQUIRED VALUES OF ASTM-A-403-2001, Grade-WP3O4L. ‘ *Carbon % 0.01 (0.03 max Manganese % 1.08 2.00"max s Silicon % 042 41.00 max Be 1G | Supnur% ott 0.030 max 23 Phosphorus % 0.036 0.045 max 8 ‘Chromium % 18.72 18.00 to 20.00 257 8S nese 972 8,00 to 12.00 B82 8S MECHANICAL a oo = 8ENGTS 543 Mpa. 485 Mpa min Besa ys 396 Mpa 4170 Mpa min. Se g GiGi Elongation 36.89%, 28.00 %_min. Sj 2%) Tteraranular Corrosion Test Practice-E SSH Gg | Sensiizing Treatment done at 675°C for 1 hour. ‘BZ | & -g Sample was bolled ina ‘Copper-Copper Sulphate 16% Sulphuric Acid test Solution for 24 hours. oP g & Sample was taken out the Prtition after 24 hours bolling washed with cold water, dried and fattened BT SB gs Some eT M-A.370-2014 through 180" over a mandrel diameter equa othe thickness ‘of the specimen. | SRD ‘Observed : No fissure or crack were observed at 20X. (2). MIGRO STRUCTURE EXAMINATION AFTER. 1GC PRACTICE E: ON The sample was eiched out with 10 % Oxalic acid and ‘observed in 100X, 500X Magnification. *. \The Microstructure of the sample shows austenitic grains wih twin bands, Some Carbide Precipitation ho Securred at grain boundaries but no single grin is completely Surrounded carbides. Specification used 1S ;226( Part 1, 2, 8 8, 3,6, $1967, RAZO14 & 2018 for Chemical Test, re 1608 (Part-’) 2048 for Mechanical Test, ASTM-A-262-2016 for IGC Test & [8, 7739(Part1)-1975 & (Part-5)-1976, RAZ0O7 for Microstrucytes Est saw End of Report .... RO a py. ofatty Manager Result pertains to samples. For TI je Industrial ‘esting Laboratory ST 7eu0- 1656 How, Mobs + 489670604 / 9430975006, oral: HOR i Note : The test report shall not be reproduced, exeept in full, withdubMiritten approval of the Laboratory | THE INDUSTRIAL DEVELOPMENT & TESTING LABORATORY Govt, Regd. No. NSIC/SL/GP/RS/REGN/WBIT-011/11 4 NABL ACCREDITED MAKARDAH ROAD, SHANPUR (CHATTERJEE SHED) DASNAGAR, HOWRAH - 711 105 Gertficate No TEST REPORT TIDL/TEST/04 Page No.: 10F 1 Test Report No. : ULR-TC524020100002836P Date; 1903/2020 Customer's Name & Address : Mis. Tesh! Engineers & Sales Promoters (P) Ltd. So, Stend Road, Ground Floor, Room No-34, Kolkata-700001 Customer Ref. Dated : 06/03/2020 ‘Type of Test 01 No Sample for Chemical, Mechanical, IGC and Microstructure Test Heat No : F 662535 Memn:t No. cut piece offiting made ftom 10" Sch. 40S pipe (0.27 mm thick) Msshanigal Test Winessed By Mr, Sagnk Nayak of TUV India Put Le Mechanar YOC Test Winessed By Mr. A Seth of Tesh Engineers & 2 Promoters (P) Lid Environmental Condition : Ambient ‘Sample received on'- 06/03/2020 jeted on:- 13/03/202 ‘The tests marked with an * are not aceredited by agpformpieted on 1310302 4 ‘This i to certify that the above sample () has been tested with he following results Description of Sample : CHEMICAL FINDINGS REQUIRED. VALUES OF. ASI ‘M-A-403-2001, Grade-WP304L *Carbon % 0.02 0.03 max : Manganese % 4.94 2.00 max is Silicon % 037 4,00 max ¥ 2 i sulphur % ote 0.030 max & 3 Phosphorus % 0.028 0.045 max BS Chromium % 18.31 18.00 to 20.00 =3 Nickel % B82 00 to 12.00 Lr a 3 Ts 538 Mpa 485 Mpa min Ys 462 Mpa 470 Mpa min Elongation 36.67% 28.00 % min. “intergranular Corrosion Test Practice-E Sensitizing Treatment done at 676°C for 1 hour. %B Sample wes boiled in a Copper-Copper Sulphate 146% Sulphuric Acid test Solution for 24 hours. & Semple was taken out the solution after 24 hors polling washed with cold water, dried and flattened Se per ASTM-A-370-2014 through 180" over a mandre ameter fequal to the thickness of the specimen. teerved : No fissure or crack were observed at 20%. ae STRUCTURE EXAMINATION AFTER IGG PRACTICE E : Oe sample was etched out with 10 % Oxalic aid and ‘observed in 100X, 500X Magnification. “aie Microstructure of the sample shows sasstontic grains with twin bands, Some Carbide Precipitation . esurred at grain boundories but no single grains complete} ‘Surrounded by carbides. 1.2, 9, 3,6, 5) 1987, RA2014 & 2078 for Chemical Test, A se08 (Part1) 2018 for Mechanical Test, ASTM-A.262-2016 fo" IGC Test & Ie. 7739(Part1)-1975 & (Part-S)-1976, RAZ007 for Microstrucyees Test eu End of Report oon his is To Certify Th: This Certificate Sample (s) not drawn by us + Laboratory pester © feed Result pertains to samples. For The Industri bh 2667-1998 (How), Mob. : 9836706349 /949337908, e-rnal a Tote’ The test report shall not be reproduced, except in full, THE INDUSTRIAL DEVELOPMENT & TESTING LABORATORY a Govt. Regd. No. NSIC/SL/GP/RS/REGN/WBY/T-011/11 1 NABL ACCREDITED MAKARDAH ROAD, SHANPUR (CHATTERJEE SHED) DASNAGAR, HOWRAH - 711 105 Certcate No, TC-6240 TEST REPORT TIDL/TEST/04 Page No.: 10F 1 Test Report No. : ULR-TC524020100002833P_ Date; 13/03/2020 Customer's Name & Address : Mls. Teshi Engineers & Sales Promoters (P) Ltd. 40, Strand Road, Ground Floor, Room No-34, Kolkata-700001 Customer Ref. Dated : 06/03/2020 Type of Test (01 No Sample for Chemical, Mechanical, IGC and Microstructure Test Heat No: F 724783, Description of Sample : __ Item: 1 No cut piece of pipe made from 3" Sch. 40S pipe (5.49 mm thick) ‘Mechanical Test Witnessed By Mr. Sagnik Nayak of TUV India Pvt. Ltd Mechanical and IGC Test Witnessed By Mr. A Sethi of Teshi Engineers & Sales Promoters (P) Ltd ‘ ‘Sample received on:- 06/03/2020 ynmental Condition : t enental Conse ae Test Completed on:- 13/03/2020 The tests marked with an * are not accredited by NABL ‘This is to certify that the above sample (s) has been tested with the following results En) CHEMICAL FINDINGS REQUIRED VALUES OF. ASTM-A-403-2001, Grade-WP304L. y “Carbon % 0.03 (0.03 max > _ Manganese % 1.75 2.00 max & 12: 2: Siicon% 04d 1.00 max ze Sulphur % oor 0.030 max 3 Phosphorus % 0.038 (0.045 max 83 Chromium % 18.23 18.00 to 20.00 2 § Nickel % 8.24 8.00 to 12.00 33 MECHANICAL aa Ti 549 Mpa, 485 Mpa min Ee vs 428 Mpa 4170 Mpa min se SG {| Elongation 35.97% 28.00 % min. 3 E(4 & ; TInteraranular Corrosion Test Practice-= SSE S| Sensitzing Treatment done at 675°C for 1 hour ‘2 2 | & y Sample was boiled in a Copper-Copper Sulphate 16% Sulphuric Acid test Solution for 24 hours. a “2 © & -B & sample was taken out the solution after 24 hours bolling washed with cold water, dried and flattened © 35 2s per ASTM-A-370-2014 through 180° over a mandrel diameter equal to the thickness of the specimen =... Observed : No fissure or crack were observed at 20X. /SSMICRO STRUCTURE EXAMINATION AFTE! PRACTICE E: ‘sample was etched out with 10 % Oxalic acid and observed in 100X, 500X Magnification. S Microstructure of the sample shows austenitic grains with twin bands, Some Carbide Precipitation occurred at grain boundories but no single grain is completely Surrounded by carbides. fecification used -IS : 228( Part- 1, 2,8, 9, 3, 6, 5)1987, RA2014 & 2018 for Chemical Test 4608-(Part-1) 2018 for Mechanical Test, ASTM-A-262-2016 for IGC Test & 18: 7739(Part-1)-1975 & (Part-5)-1976, RA2007 for Microstrycures Test. End of Report R Sample (s) not drawn by us * baberatoryDlrector of Result pertains to samples. For The Industriel /@e Testing Laboratory Ph, 2667-1938 (How), Mob. : 9836706249 /9433373906, e-mail ikt@giF8 Em /theidt leboratory@amai.com Note : The test report shall not be reproduced, except in full, without written approval of the Laboratory ee ma THE INDUSTRIAL DEVELOPMENT & TESTING LABORATORY / Govt. Regd. No. NSIC/SL/GP/RS/REGN/WB/T-O11/11 i wa scene MAKARDAH ROAD, SHANPUR (CHATTERJEE SHED) DASNAGAR, HOWRAH - 711 105 Ccertfcate No. TC-5240 TEST REPORT TIDL/TEST/04 Page No.: 10F1 Test Report No. : ULR-TC524020100002887P Date: 1303/2020 Customer's Name & Address : Mls. Teshi Engineers & Sales Promotdrs (P) Ltd. ‘40, Strand Road, Ground Floor, Room No-34, Kolkata-700001 Customer Ref. Dated : 06/03/2020 Type of Test : 01 No Sample for Chemical, Mechanical, IGC and Microstructure Test Heat No : FF 6607 Description of Sample : Item: 1 No machined test pieve of 20 mm found (Forged from 42 mm round) Tiechanieal Test Witnessed By Mr. Sagnik Nayak of TUV India Pvt. Lid Mecnanical Tot reat Witvssed By M.A Sethi of Tesh Engineers & Seles Promotes (>) ne ‘Sample received on 06/03/2020 Environmental Condition : Ambient ronal: Con aa ie Test Completed on~- 13/03/2020 ‘The tests marked with an * are not accredited by NABL ‘This ig to cerlty that the above sample (s) has been tested with the following Fesults ‘CHEMICAL EINDINGS REQUIRED VALUES OF ASTM-A-182-2008, Type-F304L, "Carbon % 0.02 (0.03 max ‘ Manganese % 1.36 2.00 max Silicon % 0.34 4.00 max Sulphur % 0.020 0,030 max Phosphorus % 0.037 0,045 max Chromium % 18.06 18.00 to 20.00 “Intergranular Corrosion Test Practice-E: Sensitizing Treatment done at 675°C for 1 hour. Scmole was boiled in a Copper-Copper Sulphate 16% Sulphuric Acid test Solution for 24 hours. E Semple was taken out the solution after 24 hours boling washed with cold water, dried and bend Through 160° over a mandrel diameter equal tothe thickness of the specimen ‘Observed : No fissure or crack were observed at 20x. MICRO STRUCTURE EXAMINATION AFTER IGG PRACTICE E : fed in 100X, 500X Magnification. ‘The sample was etched out with 10 % Oxalic acid and observ \\The Microstructure of the sample shows fine austenitic, grains with twin bands, Grain indary Carbide Precipitation is negligible. > Bpecification used - 1S : 3. &, 9, 3,6, 8)1967, RAZO14 & 2018 for Chemical Test, ie sg0e {Part-1) 2018 for Mechanical Test, ASTM-A-262-2016 for IGC Test & 1S 730(Part-1)-1975 & (Part-S)-1876, RAZOO7 for Microstrycures Test ' sane End of Report evs & Testing Laboratory Result pertains to samples. For The Indus aah 3 Nickel % 8.27 8,00 to 13.00 8 MECHA ar arena areas §. 518 Mpa 485 Mpa min é 4 294 Mpa 170 Mpa min & Elongation 37.40% 30,00 % min. = Reduction of Area 52.20% 50,00 % min. 3 iF This is To Certify That Material Covered By Note ; The test report shall not be repraduced, except in full ei i Govt. Regd. No. NSIC/SL/GP/RS/REGN/WB/T-O11/11 THE INDUSTRIAL DEVELOPMENT & TESTING LABORATORY NABL ACCREDITED MAKARDAH ROAD, SHANPUR (CHATTERJEE SHED) DASNAGAR, HOWRAH - 711 105 Cees eee TEST REPORT TIDL/TEST/04 Page No.: 10F 1. Test Report No. : ULR-TC524020100002840P Date: 19/08/2020 Customer's Name & Address : Mls. Teshi Engineers & Sales Promoters (P) Ltd. 40, Strand Road, Ground Floor, Room No-34, Kolkata-700001 Customer Ref Dated : 06/03/2020 Type of Test: 01 No Samper charial, Mechanica ISC and Meerut Tost Heat No : 19L0263 Desornionof Sample: tam:t No machined es pace of 40 mm round (Forged fo 75 mm run iiscancal Yel Winessed By Me Sogn Nayek cf TOV iP. Led Mechanical and IGC Test Witnessed By Mr. A Sethi of Teshi Engineers & Sales Promoters (P) Ltd. Environmental Condon: Ambien Same caved on oezoan The tests marked with an * are not accredited by NABL This is to certify that the above sample (s) has been tested with the following results his is To Cerify That Material Covered By Ph Sample (s) not drawn by us eee Result pertains to samples. For. ‘CHEMICAL “FINDINGS REQUIRED VALUES OF “Carbon % 0.02 0.03 max i Mangenese % 1.83 2.00 max > | Silicon % 0.27 1.00 max 3: Sulphur % 0.011 0.030 max Phosphorus % 0.036 0.045 mex Chromium % 18.19 18.00 to 20.00 Nickel % 8.16 8.00 to 13.00 ‘MECHANICAL TS 537 Mpa 485 Mpa min YS. 269 Mpa 170 Mpa min Elongation 36.40% 30.00 % min. Reduction of Area 54.93% 50.00 % min. “Intergranular Corrosion Test Practice: Sensitizing Treatment done at 675°C for 1 hour. ‘Sample was boiled in a Copper-Copper Sulphate 16% Sulphuric Acid test Solution for 24 hours. 2 Sample was taken out the solution after 24 hours bolling washed with cold water, dried and bend through 180° over a mandrel diameter equal to the thickness of the specimen. Observed : No fissure or crack were observed at 20X. MICRO STRUCTURE EXAMINATION AFTER IGC PRACTICE Ez \e'iThe sample was etched out with 10 % Oxalic acid and observed in 100X, 500X Magnification. «ihe Microstructure of the sample shows fine austenitic grains with twin bands, Grain joundary Carbide Precipitation is negligible. pecification used - IS: 226( Part- 1, 2, 8, 9, 3, 6, 5)1987, RA2014 & 2016 for Chemical Test, 18:1608-(Part-1) 2018 for Mechanical Test, ASTM-A-262-2016 for IGC Test & 1S: 7739(Part-1)-1975 & (Part-5)-1976, RAZO07 for Microstrycures Test. End of Report This Certificate Has Been Sold To 9 Dy. cae Manager § Testing Laboratory 2667-1998 (How), Mob. : 9886706849 /9435373906, email ee mers com Note : The test report shall not be reproduced, except in full, witk&ut Written approval of the Laboratory THE INDUSTRIAL DEVELOPMENT & TESTING LABORATORY Govt, Regd. No. NSIC/SL/GP/RS/REGN/WB/T-O11/11 f NABL ACCREDITED MAKARDAH ROAD, SHANPUR (CHATTERJEE SHED) DASNAGAR, HOWRAH - 711 105 Certficate No. To-5240 TEST REPORT TIDL/TEST/04 PageNo.: 10F1 Test Report No. : ULR-TC524020100002838P Date; 19/03/2020 Customer's Name & Address : Mis. Teshi Engineers & Sales Promoters (P) Ltd. 40, Strand Road, Ground Floor, Room No-34, Kolkata-700001. Customer Reef. Dated : 06/03/2020 Type of Test : (01 No Sample for Chemical, Mechanical, IGC and Microstructure Test Heat No : FF 6850 Description of Sample; Item: :1 No, machined test piece of 32 mm round (Forged from 65 mm round) ‘Mecfianical Test Witnessed By Mr. Sagnik Nayak of TUV India Pvt. Ltd Mechanical and IGC Test Witnessed By Mr. A Sethi of Teshi Engineers & Sales Promoters (P) Ltd. Environmental Conuitighe Arabient ‘Sample received on:~ 06/03/2020 — One a Menace Test Completed on:- 13/03/2020 The tests marked with an * are not accredited by NABL This is to certify that the above sample (s) has been tested with the following results CHEMICAL FINDINGS REQUIRED VALUES OF ‘ASTM-A-182-2008, Type-F3041. “Carbon % 0.02 0.03 max 4 Manganese % 148 2.00 max BiG g Silleon % 046 41.00 max © ict q Sulphur% 0.017 0.030 max > it & Phosphorus % 0.031 0.045 max & iO& chromium % 18.54 18.00 to 20.00 28 Nickel % 841 8.00 to 13.00 3&7 GS} MECHANICAL SB2Q%Ts 523 Mpa 485 Mpa min Beane vs. 287 Mpa 470 Mpa min. $a Yi ct Elongation 36.80% 30.00 % min. 3 a3 S| Reduction of Area 53.67% 50.00 % min. SSF S | Untermranular Corrosion Test Practice-E: © (9 | & g Sensitzing Treatment done at 675°C for 7 hour. 2 4 & B sample was boiled in 2 Copper-Copper Sulphate 16% Sulphuric Acid test Solution for 24 hours. £ = © & Sample was taken out the solution after 24 hours bolling washed with cold water, dried and bend through 180° over a mandrel diameter equal to the thickness of the specimen. Observed : No fissure or crack were observed at 20X. MICRO STRUCTURE EXAMINATION AFTER IGC PRACTICE DSS The sample was etched out with 10 % Oxalic acid and observed in 100X, 500X Magnification ©\he Microstructure of the sample shows fine austenitic grains with twin bands, Grain ‘sfoundary Carbide Precipitation is negligible. JejBpecifcation used - IS: 226( Part- 1,2, 8, 9, 3,6, 6/1087, RAZO14 & 2016 for Chemical Test, {S:1608-(Part-1) 2018 for Mechanical Test, ASTM-A-262-2015 for IGC Test & I: 7739(Part-1)-1975 & (Part-5)-1976, RAZ007 for Microstryoures Test End of Report in 9% Sample (s) not drawn by us ® Sees jer @ Dy. Gyfality Manager Result pertains to samples. For The Indust Testing Laboratory Ph, 12667-1938 (Howl, Mob, » 9836706349 /9433372906, e-mail: Jkea@pKeggoatpom / theidt| laboratory@gmail.com Note he test report shall not be reproduced, except in full, withett-written approval of the Laboratory THE INDUSTRIAL DEVELOPMENT & TESTING LABORATORY eS . Govt. Regd. No. NSIC/SL/GP/RS/REGN/WB/T-O11/11 ey l NABL ACCREDITED MAKARDAH ROAD, SHANPUR (CHATTERJEE SHED) DASNAGAR, HOWRAH - 711 105 Certiicate No. : 76-5240 TEST REPORT TIDL/TEST/04 Page No.: 10F 1 Test Report No. : ULR-TC524020100002639P Date: 1903/2020 Customer's Name & Address : M/s. Teshi Engineers & Sales Promoters (P) Ltd. 40, Strand Road, Ground Floor, Room No-34, Kolkata-700001 Customer Ref. : Dated : 08/03/2020 Type of Test :~ 01 No Sample for Chemical, Mechanical, |GC and Microstructure Test Heat No: C50 Description of Sample : Item 1 No. machined test plece of 25 mm round (Forged from 59 mm round) Mechanical Test Witnessed By Mr. Sagnik Nayak of TUY India Pvt. Ltd Mechanical and IGC Test Witnessed By Mr. A Sethi of Teshi Engineers & Sales Promoters (P) Li. Environmental Condition : Ambient ‘Sample received on:- 06/03/2020 Test Completed on:- 13/03/2020 The tests marked with an * are not accredited by NABL This is to certify that the above sample (s) has been tested with the following results CHEMICAL FINDINGS REQUIRED VALUES OF ‘ASTM-A~182-2008, Type-F304L. *Carbon % 0.02 (0.03 max . Manganese % 1.42 2,00 max Silicon % oat 1.00 max z= Sulphur % 0.022 0.030 max_ H 2 Phosphorus % 0.031 0.045 max 3 ‘Chromium % 18.15 18.00 to 20.00 83 Nickel % 8.03 8,00 to 13.00 ‘18 3 MECHANICAL BUGS Ts. 528 Mpa 485 Mpa min = 8c: y.8. 280 Mpa 470 Mpa min. C2 gS. 2 Q Emnaaton 37.20% 30.00% min 28a Reduction of Area, 52.49% 50.00.% min. Fe Se cmusTemraees 8388 Sensitzing Treatment done at 676°C for 1 hour. ‘ant ‘Sample was boiled in a Copper-Copper Sulphate 16% Sulphuric Acid test Solution for 24 hours. arg ‘Sample was taken out the solution after 24 hours bolling washed with cold water, dried and bend through 180° over a mandrel diameter equal to the thickness of the specimen. Ss. Observed : lo fissure or crack were obsorved at 20X. \ MICRO STRUCTURE EXAMINATION AFTER IGC PRACTICE E:

You might also like