You are on page 1of 5

9060 P01 IT-SOFC Brazing-Internal review-4

Date:-18/02/2015
Attributes:-
1) Hermetic sealing
2) Thermal stability
3) CELL Positive contact with current collecting leads

Experiment summery

Trial No

1
2
3
1) Hermetic sealing:-
 Hermetic sealing is achieve with TiCuSil Foil with bottom sealing schema with
impervious substrate ( metal plate )
 With porous substrate trials satisfactory completed optimized parameter
achieved
 After stabilizing cell architecture final schema will be implement with optimized
process parameter

Braz
e
LSCF
Join
GDC t
NiO+GD
SS316/SS
C
430

End Plate
Brazing schema for TiCuSil foil
Thermal stability:- Thermal cycling (24˚c -800˚c ) of joint is tested 10 Number cycle is
tested
observation :- Joint is stable after thermal cycling

Thermal cycling graph

Joint before thermal cycling


joint after thermal cycling
Positive contact with current collecting leads :-
Experiment Conduct for insuring positive contact with current collecting
lead fixture is designed for brazing
observation :- positive contact is achieve

cut section of brazing joint (SS430 End Plate SS 316 Porous substrate

positive contact achieved

Cross section view macrograph


Brazing for prototype

Cell of batch -2 brazed with interconnect

Stack of cell 4 brazing completed For Prototype Stack of cell 4 completed For Prototype