DR-ZX (1) Operation Manual PDF
DR-ZX (1) Operation Manual PDF
ZX
Operation Manual
EPVC_Mid
Diagnostic / Monitoring / Adjusting tools for following excavators.
Hitachi EX-1 (USE series), EX-2 (60 to 300), EX-3 (60 to 310) EX-5 (60 to 370), ZAXIS (70 to 380)
Fiat Hitachi FH-2 series, FH-3 series, EX series (less than 40 tons)
EPVC_Mini
Diagnostic / Monitoring / Adjusting tools for following excavators.
Hitachi EX33Mu & EX58Mu
HMS_LargeMid
Monitoring data download / Data logger setting following excavators.
Hitachi ZAXIS (70 to 850)
John Deere C series (80C to 800C)
MIC_Mining
Monitoring data download / Data logger setting / Monitoring / Diagnostic following excavators.
Hitachi EX1200-5/5C, EX1900-5, EX2500-1/5, EX3500-1/2/3, EX3600-5, EX5500-5
EPVC_LARGE
Operation Manual
NOTE
This manual is based on Hitachi ZX series. Screen / Function /
Procedure are vary by model.
1. Necessary Tools & Cable Connection
2. MODE
OPERATION MODE
3. Operation Mode – How to Start Dr.ZX with Operation Mode
4. Operation Mode – Self-Diagnostic
5. Operation Mode – Monitoring
6. Operation Mode – Special Function (WU Deactivation)
7. Operation Mode – Special Function (ECO Deactivation)
8. Operation Mode – Special Function (Pump Adjustment)
SERVICE MODE
9. Service Mode – How to Start Dr.ZX with Service Mode
10. Service Mode – Learning Data Display
11. Service Mode – Monitor Panel LCD Control
12. Service Mode – Parameter Change
13. Service Mode – Act/Deact of Parameters
(a) Palm OS PDA (b) Serial cable (c) Dr.ZX communication cable
Dr.ZX must be installed. Hitachi For SONY Clie PEG-TJ25 This is Hitachi unique part. Make an
recommends following models. Purchase from CPD. P/no. is order to your parts ordering channel.
SONY 4629330 (Hitachi unique Hitachi part no. is 4476512.
Clie PEG-TJ25 parts).
PalmOne Inc. For PalmOne PDAs
m125 / 130 / 500 / 505 / 515 Purchase from local market.
Tungsten T2 / T3 / C Product name is HotSync serial
Cable connection
Serial cable
Turn key switch Check engine Connect Dr.ZX to Turn key switch Switch on Palm.
“OFF”. learning switch is equipment. “ON”.
OFF.
Monitoring
View / Recording
Special Function
3. Operation Mode – How to Start Dr.ZX with Operation Mode (2/4)
(a) Turn key switch “OFF” (b) Check Engine learning switch is OFF
Fuse box
OFF
Stamp
(g) Select “EPVC_Large”. (h) Start operation mode (i) Model / Version information
Error code(s) that detected will Tap “Retry B” for retrying. If Dr.ZX could not detect any error(s),
display to Palm. Tap “ESC” for retry. above message will display. Tap
“ESC”.
4. Operation Mode – Self-Diagnostic (3/3)
(f) Still error(s) detected (g) Explanation of each code (h) Explanation of each code
If Dr.ZX still detect any error(s) , error Message will show meanings of each Tap “ESC” fir quit self-diagnostic.
code(s) will display. Tap “Details” for code, and corrective action. Tap
check error(s). “Next” for view additional information
or other code. NOTE
Refer service manuals for
troubleshooting.
5. Operation Mode – Monitoring (1/5)
Operation mode Select Monitor Enter model Select item. Start monitoring.
menu. display. code & serial no. (Max. four items)
Start recording. Select data bank If data bank isn’t Write recorded Enter comment if
that store empty, Dr.ZX will data to data you want.
recorded data. ask overwrite. bank.
NOTE
If you did not enter model code & equipment
serial no., you can’t record monitoring data to
Palm.
5. Operation Mode – Monitoring (2/5)
(a) Start Monitoring (b) Enter model code & s/no.
TIP
You can use keyboard to enter
model code & serial no. by tap
“abc” or “123” on GRAFFITI area.
Tap “ ” of Monitor Display Tap columns and enter model code &
serial no. If you did not enter model
code & serial no., you can’t record
monitoring data.
After enter model & serial no., tap Tap “ ” of item you want monitor. You
“OK”. If you don’t need to record can monitor four items in once.
Number of
monitoring data, no need to enter Clear selected
selected item(s).
model code & serial no. Just tap “OK”. item(s).
5. Operation Mode – Monitoring (3/5)
(e) Start display data (f) Start display monitoring data
After selecting item(s), tap “Start” for Item(s) will display. Screen will vary
display monitoring data. by selected items. Tap “Hold” for
pause data. If you want quit, tap
“ESC”.
NOTE
If you did not enter
Tap “Record” for record monitoring During recording, above screen will
model code & serial no.,
data. Dr.ZX will record data for three display.
“Record” button shall
(3) seconds.
not appear.
5. Operation Mode – Monitoring (4/5)
(i) Select data bank (j) Data bank is not empty (k) Data bank is empty
Tap data bank (figure) that you want If selected data bank already has If selected data bank is empty, above
to store recorded data. data, above screen will appear. Tap screen will display. Tap “Write” for
“OverWrite” for store recorded data, store recorded monitoring data.
tap “ESC” for back to previous menu.
After data stored, confirmation screen Tap comment column, and enter
NOTE
will display. Tap “ESC” to quit, or if comment. After entering, tap “OK”.
Click here for how to repaly
you want enter comment, tap
recorded data.
“Comment”.
5. Operation Mode – Monitoring (5/5)
Items can be monitored (vary by model)
6. Operation Mode – Special Function (WU Deactivation –1/2)
WU Function.
WU stands for Warming-Up. This function is, when start engine while hydraulic oil
temperature is less than zero (0) Celsius, computer will increase low idle rpm for warm
hydraulic oil quickly.
6. Operation Mode – Special Function (WU Deactivation –2/2)
(a) Select special function (b) Select WU deactivation (c) Select WU deactivation
Tap “ ” of Special Function. Tap “ ” of WU Deactivation.. Tap “Execute for Deactivation. If you
want back to previous menu, tap
“ESC”.
(d) Confirmation
ECO Function
ECO stands for ECOnomy. This function is, when all levers are in neutral position,
computer will reduce engine rpm to 1600min-1 gradually. If any lever(s) are operated, engine
rpm will back.
7. Operation Mode – Special Function (ECO Deactivation –2/2)
(a) Select special function (b) Select ECO deactivation (c) Select WU deactivation
Tap “ ” of Special Function. Tap “ ” of ECO Deactivation.. Tap “Execute for Deactivation. If you
want back to previous menu, tap
“ESC”.
(d) Confirmation
Switch OFF Turn key switch Remove both Confirm sensors Check engine
Palm. “OFF”. angle sensors are connecting to learning switch is
from pump. harness. OFF.
Connect Dr.ZX to Start engine. Confirm engine Switch on Palm. Start Dr.ZX.
equipment. is running with
low idle.
Pump-2 Pump-1
sensor sensor
Remove two (2) angle sensors from
pump. When removing, take care not
to lose internal spacer & fastener
ZX450 & ZX500 ZX600 & ZX800
spring.
8. Operation Mode – Special Function (Pump Adjustment –4/9)
(d) Confirm connection (e) Check Engine learning switch is OFF
Fuse box
Connect to OFF
harness
Stamp
Confirm engine control dial position Main switch is vary by Palm model.
lowest engine speed. Above shows Palm m500 / 505 / 515.
(j) Start Dr.ZX (k) Select “EPVC_Large”. (l) Start operation mode
Check model. If model is correct, tap Tap “ ” of Special Function. Tap “ ” of pump adjustment.
“correct”, if not tap “ESC” and contact
to Hitachi.
NOTE
After tap “Max. Disp.
Holding”, wait more than
Tap “ ” of pump adjustment. five (5) seconds. Computer Return signals (voltage) from angle
will operate main pump to sensors will display.
maximum displacement
position.
8. Operation Mode – Special Function (Pump Adjustment –7/9)
(r) Adjust sensor shaft
With the punch mark on the angel sensor shaft, towards the A Sensor Main pump
opposites side of the harness, and adjust (turn) shaft that
signal voltage is as following specification.
ZX450 & ZX500 Angle Sensors Location ZX450 & ZX500 Angle Sensors Location
Pump-2 Pump-1
sensor sensor
Harness Harness
Side Side Harness Harness
Side Side
8. Operation Mode – Special Function (Pump Adjustment –9/9)
(t) Tighten bolts (u) Quit pump adjustment
Turn key switch Wait more than Connect Dr.ZX to Switch on the Turn key switch
“OFF”. ten(10) seconds. equipment. engine-learning “ON”.
switch.
Confirm current Select Special Service mode Check Engine Learning Data
Dr.ZX mode. function. menu.
Change Parameter.
Fuse box
NOTE
Wait more than ten (10) ON
seconds, after key
switch is turned off.
Stamp
NOTE
Main switch is vary by Palm model. Tap “Dr.ZX” icon on Palm.
Shall not start engine.
Above shows Palm m500 / 505 / 515.
(g) Select “EPVC_Large” (h) Start service mode (i) Model / Version information
Tap “ ” of “Learning Data Display” in Tap “ ” of item you want to view. EC Motor position will display. Tap
service mode menu. “ESC” for quit.
Monitor Panel
Service mode Select “Monitor Select “Engine Select “display” Select “Execute”.
menu. Display”. Actual Speed”. or “not to
display”.
Tap “ ” of “Monitor Display” in Tap “ ” of item you want to view on Tap “Disp” for allow to display
service mode menu. monitor panel. information, and tap “NoDisp” for not
allow to display information.
NOTE
You have to carry out “Act/Deact of Parameters”
function after changing parameters. Otherwise
changed parameter(s) shall not transfer to
equipment main computer.
12. Service Mode – Parameter Change (2/4)
(a) Select “Parameter Change” (b) Select item
Tap “ ” or “ ” to
changeover items.
TIP
You can use keyboard to enter
figures. Tap “123” on GRAFFITI
are.
Tap entering column, and enter
figures to be adjusted.
12. Service Mode – Parameter Change (3/4)
(c) Confirmation screen (c) Quit
Tap “ ” of “Parameter Change” in Select activation or Tap “Execute”, and tap “ESC” to quit.
service mode menu. deactivation.
(c-1) Deactivation
View manuals.
Play recorded
monitoring data.
14. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (2/2)
(a) Switch “ON” Palm (b) Start Dr.ZX
Main switch is vary by Palm model. NOTE Tap “Dr.ZX” icon on Palm.
Above shows Palm m500 / 505 / 515. No need to hook up
with equipment.
Tap “ ” of EPVC_Large.
15. Stand Alone Mode – Change Password (1/3)
Main screen. Tap “Password”. Enter current Enter new Re-enter new
password. password. password.
TIP
You can use keyboard to enter
password. Tap “abc” on GRAFFITI
are.
(c) Tap “Execute” (d) Enter new password (e) Tap “Execute”
15. Stand Alone Mode – Change Password (3/3)
(f) Re-enter new password (g) Tap “Execute” (h) Tap “ESC”
View service
mode manual.
View engine
learning mode
manual.
16. Stand Alone Mode – View Manuals (2/2)
(a) Main screen (b) Select Manual
(c) Operation mode manual (d) Service mode manual (e) Engine learning mode manual
NOTE
To play recoded data, you have to record monitoring
data before.
17. Stand Alone Mode – Play Recorded Data (2/2)
(a) Main screen (b) Select data bank (c) Recoded data
Tap ”Record Disp”. Tap number of data bank that you Recorded monitoring data will display.
want to play, and tap “Play Back”. Tap “ESC” to quit.
EPVC_MID
Operation Manual
NOTE
This manual is based on Hitachi ZX series. Screen / Function /
Procedure are vary by model.
1. Necessary Tools & Cable Connection
2. MODE
OPERATION MODE
3. Operation Mode – How to Start Dr.ZX with Operation Mode
4. Operation Mode – Self-Diagnostic
5. Operation Mode – Monitoring
6. Operation Mode – Special Function (WU Deactivation)
7. Operation Mode – Special Function (ECO Deactivation)
SERVICE MODE
8. Service Mode – How to Start Dr.ZX with Service Mode
9. Service Mode – Learning Data Display
10. Service Mode – Monitor Panel LCD Control
11. Service Mode – Parameter Change
(a) Palm OS PDA (b) Serial cable (c) Dr.ZX communication cable
Dr.ZX must be installed. Hitachi For SONY Clie PEG-TJ25 This is Hitachi unique part. Make an
recommends following models. Purchase from CPD. P/no. is order to your parts ordering channel.
SONY 4629330 (Hitachi unique Hitachi part no. is 4476512.
Clie PEG-TJ25 parts).
PalmOne Inc. For PalmOne PDAs
m125 / 130 / 500 / 505 / 515 Purchase from local market.
Tungsten T2 / T3 / C Product name is HotSync serial
Cable connection
Serial cable
Turn key switch Check engine Connect Dr.ZX to Turn key switch Switch on Palm.
“OFF”. learning switch is equipment. “ON”.
OFF.
Monitoring
View / Recording
Special Function
3. Operation Mode – How to Start Dr.ZX with Operation (2/5)
(a) Turn key switch “OFF” (b) Check Engine learning switch is OFF
Stamp
(g) Select “EPVC_Mid” (h) Start operation mode (i) Model / Version information
Error code(s) that detected will Tap “Retry B” for retrying. If Dr.ZX could not detect any error(s),
display to Palm. Tap “ESC” for retry. above message will display. Tap
“ESC”.
4. Operation Mode – Self-Diagnostic (3/3)
(f) Still error(s) detected (g) Explanation of each code (h) Explanation of each code
If Dr.ZX still detect any error(s) , error Message will show meanings of each Tap “ESC” fir quit self-diagnostic.
code(s) will display. Tap “Details” for code, and corrective action. Tap
check error(s). “Next” for view additional information
or other code. NOTE
Refer service manuals for
troubleshooting.
5. Operation Mode – Monitoring (1/5)
Operation mode Select Monitor Enter model Select item. Start monitoring.
menu. display. code & serial no. (Max. four items)
Start recording. Select data bank If data bank isn’t Write recorded Enter comment if
that store empty, Dr.ZX will data to data you want.
recorded data. ask overwrite. bank.
NOTE
If you did not enter model code & equipment
serial no., you can’t record monitoring data to
Palm.
5. Operation Mode – Monitoring (2/5)
(a) Start Monitoring (b) Enter model code & s/no.
TIP
You can use keyboard to enter
model code & serial no. by tap
“abc” or “123” on GRAFFITI area.
Tap “ ” of Monitor Display Tap columns and enter model code &
serial no. If you did not enter model
code & serial no., you can’t record
monitoring data.
After enter model & serial no., tap Tap “ ” of item you want monitor. You
“OK”. If you don’t need to record can monitor four items in once.
Number of
monitoring data, no need to enter Clear selected
selected item(s).
model code & serial no. Just tap “OK”. item(s).
5. Operation Mode – Monitoring (3/5)
(e) Start display data (f) Start display monitoring data
After selecting item(s), tap “Start” for Item(s) will display. Screen will vary
display monitoring data. by selected items. Tap “Hold” for
pause data. If you want quit, tap
“ESC”.
NOTE
If you did not enter
Tap “Record” for record monitoring During recording, above screen will
model code & serial no.,
data. Dr.ZX will record data for three display.
“Record” button shall
(3) seconds.
not appear.
5. Operation Mode – Monitoring (4/5)
(i) Select data bank (j) Data bank is not empty (k) Data bank is empty
Tap data bank (figure) that you want If selected data bank already has If selected data bank is empty, above
to store recorded data. data, above screen will appear. Tap screen will display. Tap “Write” for
“OverWrite” for store recorded data, store recorded monitoring data.
tap “ESC” for back to previous menu.
After data stored, confirmation screen Tap comment column, and enter
NOTE
will display. Tap “ESC” for quit, or if comment. After entering, tap “OK”.
Click here for how to replay
you want enter comment, tap
recorded data.
“Comment”.
5. Operation Mode – Monitoring (5/5)
Items can be monitored (vary by model)
6. Operation Mode – Special Function (WU Deactivation –1/2)
WU Function.
WU stands for Warming-Up. This function is, when start engine while hydraulic oil
temperature is less than zero (0) Celsius, computer will increase low idle rpm for warm
hydraulic oil quickly.
6. Operation Mode – Special Function (WU Deactivation –2/2)
(a) Select special function (b) Select WU deactivation (c) Select WU deactivation
Tap “ ” of Special Function. Tap “ ” of WU Deactivation.. Tap “Execute for Deactivation. If you
want back to previous menu, tap
“ESC”.
(d) Confirmation
ECO Function
ECO stands for ECOnomy. This function is, when all levers are in neutral position,
computer will reduce engine rpm to 1600min-1 gradually. If any lever(s) are operated, engine
rpm will back.
7. Operation Mode – Special Function (ECO Deactivation –2/2)
(a) Select special function (b) Select ECO deactivation (c) Select WU deactivation
Tap “ ” of Special Function. Tap “ ” of ECO Deactivation.. Tap “Execute for Deactivation. If you
want back to previous menu, tap
“ESC”.
(d) Confirmation
Turn key switch Wait more than Connect Dr.ZX to Switch on the Turn key switch
“OFF”. ten(10) seconds. equipment. engine-learning “ON”.
switch.
Confirm current Select Special Service mode Check Engine Learning Data
Dr.ZX mode. function. menu.
Change Parameter.
Stamp
NOTE
Wait more than ten (10)
ZX110 & up, 120C & up
seconds, after key
switch is turned off.
NOTE
Main switch is vary by Palm model. Tap “Dr.ZX” icon on Palm.
Shall not start engine.
Above shows Palm m500 / 505 / 515.
(g) Select “EPVC_Large” (h) Start service mode (i) Model / Version information
Tap “ ” of “Learning Data Display” in Tap “ ” of item you want to view. EC Motor position will display. Tap
service mode menu. “ESC” for quit.
NOTE
“Boom Angle Sensor Correction
Value” & “Arm Angle Sensor
Correction Value” are used for
equipment which has lifting load (c) Engine max. speed position
monitor (option item).
Monitor Panel
Service mode Select “Monitor Select “Engine Select “display” Select “Execute”.
menu. Display”. Actual Speed”. or “not to
display”.
Tap “Disp” for allow to display Tap “Execute” for activate control. If execution is completed, above
information, and tap “NoDisp” for not message will display. Tap “ESC” for
allow to display information. quit.
11. Service Mode – Parameter Change (1/4)
Please click here for view items can be changed parameters.
Tap “ ” or “ ” to
changeover items.
TIP
You can use keyboard to enter
figures. Tap “123” on GRAFFITI
are.
Tap entering column, and enter
figures to be adjusted.
11. Service Mode – Parameter Change (3/4)
(e) Confirmation screen (f) Quit
View manuals.
Play recorded
monitoring data.
12. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (2/2)
(a) Switch “ON” Palm (b) Start Dr.ZX
Main switch is vary by Palm model. NOTE Tap “Dr.ZX” icon on Palm.
Above shows Palm m500 / 505 / 515. No need to hook up
with equipment.
Tap “ ” of EPVC_Large.
13. Stand Alone Mode – Change Password (1/3)
Main screen. Tap “Password”. Enter current Enter new Re-enter new
password. password. password.
TIP
You can use keyboard to enter
password. Tap “abc” on GRAFFITI
are.
(c) Tap “Execute” (d) Enter new password (e) Tap “Execute”
13. Stand Alone Mode – Change Password (3/3)
(f) Re-enter new passwrod (g) Tap “Execute” (h) Tap “ESC”
View service
mode manual.
View engine
learning mode
manual.
14. Stand Alone Mode – View Manuals (2/2)
(a) Main screen (b) Select Manual
(c) Operation mode manual (d) Service mode manual (e) Engine learning mode manual
NOTE
To play recoded data, you have to record monitoring
data before.
15. Stand Alone Mode – Play Recorded Data (2/2)
(a) Main screen (b) Select data bank (c) Recoded data
Tap ”Record Disp”. Tap number of data bank that you Recorded monitoring data will display.
want to play, and tap “Play Back”. Tap “ESC” to quit.
EPVC_Mini
Operation Manual
NOTE
This manual is based on Hitachi ZX series. Screen / Function /
Procedure are vary by model.
1. Necessary Tools & Cable Connection
2. Function
3. How to Start EPVC_Mini
4. Displaying & Deleting Fault Code History
5. Troubleshooting
6. Fault Codes List
7. Zone check
8. Monitoring
9. Current Correction
1. Necessary Tools & Cable Connection
Necessary tools
(a) Palm OS PDA (b) Serial cable (c) Dr.ZX communication cable
Dr.ZX must be installed. Hitachi For SONY Clie PEG-TJ25 This is Hitachi unique part. Make an
recommends following models. Purchase from CPD. P/no. is order to your parts ordering channel.
SONY 4629330 (Hitachi unique Hitachi part no. is 4476512.
Clie PEG-TJ25 parts).
PalmOne Inc. For PalmOne PDAs
m125 / 130 / 500 / 505 / 515 Purchase from local market.
Tungsten T2 / T3 / C Product name is HotSync serial
Cable connection
Serial cable
Troubleshooting
This function will display fault code that controller is sensing. If any trouble is
occurring, PDA will shoe fault code. If PDA could not detect any fault, PDA will display
“00” on each items.
ZONE Check
This function will display current boom & swing position.
Monitor Display
This function allows monitoring item. You can check four items in once.
Current Correction
This function allows to correct following items
(a) Boom & swing deceleration currency (adjusting range is +/- 100 mA)
Use this function when you feel deceleration speed is too slow.
(b) Boom stop position (adjusting range is +/- 20 degree)
Use this function when you feel boom stop position it too close or far.
3. How to Start EPVC_Mini -1/3
Turn key switch Connect Dr.ZX to Turn key switch Switch on PDA Start Dr.ZX.
“OFF”. equipment. “ON”.
Kind menu will Main menu will Software version Equipment Main menu will
display. Select display. Select will display. information will display.
“EPVC_Mini”. “Mu” type. Select “Start”. display. Select
“OK”.
3. How to Start EPVC_Mini -2/3
(a) Turn key switch “OFF” (b) Connect cable to equipment (c) Turn key switch “ON”
Above shows PalmOne m500. Switch Tap “Dr.ZX” icon. Tap “ ” of “EPVC_Mini”.
location is vary by model.
3. How to Start EPVC_Mini -3/3
(g) Main menu (h) Software version (i) Equipment information
Tap “ ” of “Mu Type”. Tap “Kind Software version will display. Tap Equipment information will display.
Menu” to back to kind menu. “Start” to continue. Tap “Exit” to back Tap “OK” to continue. Tap “Model
to main menu. Menu” to back to software version
display screen.
Fault (s) are Fault code(s) will Tap “Info”. Content of fault
detected. display. will display.
Tap “ ” of “Fault Code Disp & Del”. If there aren’t any fault recorded in
controller, above message will
display. Tap “Exit” to
Fault codes will display (max. 59 Tap “Info.” Meaning of each code will display.
faults). Tap ““ ” or “ ” to Tap ““ ” or “ ” to check other code.
changeover screen. Tap “Exit” to back to fault code list.
4. Displaying & Deleting Fault Code History -3/3
(g) Delete codes (h) Confirmation screen (c) End message
Tap “Delete”. This will clear all fault Tap “Yes” to delete code. Tap “NO” to When clearing is finished, end
code history recording in controller. back to code list. message will display. Tap “OK” to
back to item menu.
5. Troubleshooting
(a) Item menu (b)List of fault codes (c) Check meaning of fault code
Tap “ ” of “Troubleshooting” in item If any faults are occurring, fault code Tap “Info.” to show meaning of each
menu. will display. If no faults are occurring, code. Tap “Exit” to back to item menu.
code will display as “00”. Tap “HOLD”
to check content of fault.
Max. swing
(Right side)
BJL1
BJL2
B1
Right swing
B2 B4 B7
Center swing
Position
BJL3
BJL4
BJL6
Left swing B3 B5 B6
Max. swing
(Left side)
Max. swing
S6
(Right side)
Right swing S1
SJL4
SJL5
S2
Center swing
Position S3 SJL2
SJL3
Left swing
S4
Max. swing
(Left side)
Tap “Start” to start monitoring. Item(s) that you selected will display
(information will vary by item). Tap
“Hold” to pause data, and tap “Exit” to
quit monitoring.
9. Current Correction –1/2
(a) Item menu (b) Item menu (c) Changing value
Tap “ ” of “Current Correction”. Tap “ ” of item you want change Tap figures you want to change, and
current. tap “OK”. To find figures tap “ ” or “ ”.
If you selected “boom stop position”
unit will be degree.
TIP
You can use keyboard to enter
password. Tap “abc” on GRAFFITI
area.
After entering password, tap “OK”. End message will display. Tap “Exit”
to quit.
HMS_LargeMid
Operation Manual
NOTE
This manual is based on Hitachi ZX series. Screen / Function /
Procedure are vary by model.
DOWNLOADING
9. Data Downloading – How to Start Dr.ZX
10. Data Downloading – Download
11. Data Downloading – Check Downloaded Data
ICX DIAGNOSIS
12. ICX Self Diagnoses – Flow
13. ICX Self Diagnoses – Operation
CHANGE PASSWORD
14. Change Password – Flow
15. Change Password – Operation
1. Necessary Tools & Cable Connection
Necessary tools
(a) Palm OS PDA (b) Serial cable (c) Dr.ZX communication cable
Dr.ZX must be installed. Hitachi For SONY Clie PEG-TJ25 This is Hitachi unique part. Make an
recommends following models. Purchase from CPD. P/no. is order to your parts ordering channel.
SONY 4629330 (Hitachi unique Hitachi part no. is 4476512.
Clie PEG-TJ25 parts).
PalmOne Inc. For PalmOne PDAs
m125 / 130 / 500 / 505 / 515 Purchase from local market.
Tungsten T2 / T3 / C Product name is HotSync serial
Cable connection
Serial cable
Turn key switch Confirm the Connect Dr.ZX to Turn key switch Switch on Palm.
“OFF”. engine-learning equipment. “ON”.
switch is OFF.
Stamp
Connect
Hitachi ZAXIS110 & up
John Deere 120C & up
Connect
NOTE
Main switch is vary by Palm model. Tap “Dr.ZX” icon on Palm.
Shall not start engine.
Above shows Palm m500 / 505 / 515.
(g) Select “HMS_LargeMid” (h) Select “Communication Start” (i) Select “Set-ICX”.
TIP
You can use keyboard to enter
password. by tap “abc” or “123” on
GRAFFITI area.
Tap entering column, and enter After enter password, tap “OK”.
password. Default password is
zx2000.
(i) Tap “Start” (j) Select “ICX Initial Setting” (j) ICX initializing menu
NOTE
Perform ICX initialization on following cases.
(a) When delivered new equipment to customer.
(b) When replaced ICX.
(c) When error(s) on downloaded data.
Tap “ ” of “Enter Time Diff. from Check current time difference. If it is Tap up-arrow or down-arrow to find
UTC”. If item is not in menu, tap “ ” correct tap “ESC”, if you want to correct time difference.
or “ ” to changeover menus. correct, tap “Correct”. Time difference
table is on next page.
NOTE
Please carry out this setting, after
set time difference from GMT.
Tap “ ” of “Enter Date and Time”. . If Check local time. If it is wrong, tap
item is not in menu, tap “ ” or “ ” to “Correct” for correction.
changeover menus.
TIP
You can use keyboard to enter
password. by tap “abc” or “123” on
GRAFFITI area.
Tap entering column and enter
current local time.
6. ICX Initializing – Set Local Time -2/2
(d) Tap “OK” (e) Check local time (f) Confirmation screen
After entering local time, tap “OK”. If local time is correct, tap “OK” for Tap “OK”
set. If not correct, tap “NG” to
re-enter.
7. ICX Initializing – Synchronize Service-meter
(b) Select Hour Meter Setting (c) Check current service meter (d) Confirmation screen
Tap “ ” of “Initial Hour Meter If figures are difference, tap “Set” for Tap “OK”.
Setting”. . If item is not in menu, tap synchronizing. ICX will set it hour
“ ” or “ ” to changeover menus. meter as external hour meter.
8. ICX Initializing – Model Code & Serial No. Setting -1/2
(b) Select Enter Model & Serial no. (c) Tap “OK” (d) Tap “Correct”
Tap “ ” of “Enter Model and Serial Even if model code & Serial no. are
No.”. If item is not in menu, tap “ ” or correct, tap “Correct”.
“ ” to changeover menus.
NOTE-2
When entering model code, you have to
add “0” (zero) in front of model code.
If model code and/or serial no. are incorrect,
For example, if model code is 1G6, you
tap column, and enter correct model code
have to enter 01G6.
and/or serial no. Equipment model code &
serial no. are stamp on name plate.
8. ICX Initializing – Model Code & Serial No. Setting -2/2
(f) Tap “OK” (g) Confirmation screen (h) Internal memory clear
After correcting, tap “OK”. Tap “OK” When initialize ICX, you have to clear
ICX internal memory. Otherwise you
can’t view data in some cases.
NOTE
Shall not download immediately after
memory clear, because data is empty
(Dataviewer could not recognize empty
data as downloaded data. Operate
equipment at least an hour, and
download data.
9. Data Downloading – How to Start Dr.ZX -1/5
Turn key switch Confirm the Connect Dr.ZX to Turn key switch Switch on Palm.
“OFF”. engine-learning equipment. “ON”.
switch is OFF.
Download Menu
9. Data Downloading – How to Start Dr.ZX -2/5
(a) Turn key switch “OFF” (b) Check Engine learning switch is OFF
Stamp
Connect
ZX110 & up, 120C & up
Connect
NOTE
Main switch is vary by Palm model. Tap “Dr.ZX” icon on Palm.
Shall not start engine.
Above shows Palm m500 / 505 / 515.
(g) Select “HMS_LargeMid” (h) Select “Communication Start” (i) Select “Set-ICX”.
Palm Operation
Tap “ ” of “Data Download”. Download will start automatically after Download will start automatically after
selecting data download. If you want selecting data download. If you want
to cancel download, tap “Cancel”. to cancel download, tap “Cancel”.
11. Data Downloading – Check Downloaded Data
Flow
Palm Operation
Stamp
Connect
ZX110 & up, 120C & up
Connect
NOTE
Main switch is vary by Palm model. Tap “Dr.ZX” icon on Palm.
Shall not start engine.
Above shows Palm m500 / 505 / 515.
(g) Select “HMS_LargeMid” (h) Select “Communication Start” (i) Select “Set-ICX”.
TIP
You can use keyboard to enter
password. by tap “abc” or “123” on
GRAFFITI area.
Tap entering column, and enter After enter password, tap “OK”.
password. Default password is
zx2000.
(g) Error(s) detected (h) Still error has detected (h) Still error has detected
If any errors have detected, error If still errors have detected, error Content of error will display. Tap “ ”
code will display. Tap “Retry” for code will display. Tap “Detail” to check or “ ” to changeover error.
confirmation. content of each error. Tap ”ESC” to quit.
14. Change Password – Flow
Turn key switch Confirm the Connect Dr.ZX to Turn key switch Switch on Palm.
“OFF”. engine-learning equipment. “ON”.
switch is OFF.
Stamp
Connect
ZX110 & up, 120C & up
Connect
NOTE
Main switch is vary by Palm model. Tap “Dr.ZX” icon on Palm.
Shall not start engine.
Above shows Palm m500 / 505 / 515.
(g) Select “HMS_LargeMid” (h) Select “Communication Start” (i) Select “Set-ICX”.
TIP
You can use keyboard to enter
password. by tap “abc” or “123” on
GRAFFITI area.
Tap entering column, and enter After enter password, tap “OK”.
password. Default password is
zx2000.
TIP
You can use keyboard to enter
password. Tap “abc” on GRAFFITI
are.
(f) Re-enter new password (g) Tap “Execute” (h) Tap “ESC”
NOTE
New password will apply to all
Dr.ZX function.
MIC Mining
Super Large Excavators (EX1200-5 & up) Monitoring System
Operation Manual
Dr.ZX must be installed. Hitachi Purchase from local market. Provide This is Hitachi unique part. Make an
recommends following models. cable that adapt to your Palm. order to your parts ordering channel.
SONY Hitachi part no. is 4486988.
CLIe PEG-TJ25
PalmOne Inc.
m125 / 130 / 500 / 505 / 515
Tungsten T2 / T3 / C
Palm
Serial cable
Download cable
Equipment
2. Connector Location on Equipment for Monitoring
(a) EX1200-5 (b) EX1200-5C (c) EX1900-5 & up
3. How to start MIC_Mining – 1/3
Turn key switch to off Connect cable to Check lamp on Check jumper
position. equipment. download cable is off. connector is not
connecting to cable.
Start MIC_Mining.
3. How to start MIC_Mining – 2/3
(01) Turn key switch “OFF” (02) Connect cable to equipment (03)
(c)Check
Turn key
Jumper
switch
connector
“ON”
(c) Turn
(04) Turn key
key switch
switch “ON”
“ON” (05) Check lamp is blinking (06) Switch on PDA
When data could not view on data viewer. MEC-P Clear DLU internal memory.
Tap “ ” to set time difference Tap menu icon. Tap “SettingAdjustment” in tools
between GMT. List of time difference menu.
is at Code “SAD-P” –9/9.
(04) Date & Time adjustment (05) Date & Time adjustment
TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.
Date & time current recorded in DLU Tap “Date”. Tap “Today”. Date & year will set
will display. If you have to adjust, tap automatically. Before setting date,
“Change”, if no need to change, tap confirm date on Palm is same as
“Set”. local.
(09) Date & Time adjustment (10) Date & Time adjustment (11) Date & Time adjustment
Tap “Time”. Tap hour and adjust to local by Tap minute and adjust to local by
tapping “ ” “ ”. tapping “ ” “ ”.
5. Code “SAD-P” –4/9
(12) Date & Time adjustment (13) Date & Time adjustment (14) Date & Time adjustment
Tap minute and adjust to local by If date & time are same as local, tap Message will display. Tap “Ok” to set
tapping “ ” “ ”. “Set”. date & time. Tap “Back” to correct
date & time.
(15) Service meter adjustment (16) Service meter adjustment (17) Service meter adjustment
TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.
(20) Service meter adjustment (21) Service meter adjustment (22) Service meter adjustment
Message will display. Tap “Ok” to set Main screen Tap menu icon.
service meter reading. Tap “Back” to
correct service meter reading.
TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.
(31) Serial no. check (31) Serial no. check (32) Confirmation
Tap menu icon. Tap “SystemCheck” in tools menu. Confirm every information on this
screen are correct. If not, please
re-adjust. If serial no. doesn’t match,
perform SAI-P.
5. Code “SAD-P” –9/9
6. Code “SAI-P” –1/9
When perform this code
Perform this code, when you replaced DLU. Otherwise you can’t view monitoring data on data viewer.
TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.
TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.
Serial no. currently recorded in DLU Tap serial no. column, and enter
will display. Tap “Change”. correct serial no.
(08) Serial no. correcting (09) Serial no. correcting (10) Serial no. correcting
After entering correct serial no., tap If serial no. you entered is correct, tap Tap “Yes” to clear DLU internal
“Set”. “Ok”. If you want to re-enter serial no., memory. Otherwise data will corrupt.
tap “Back”.
6. Code “SAI-P” –4/9
(11) Serial no. correcting (12) Set time difference (13) Date & Time adjustment
(14) Date & Time adjustment (15) Date & Time adjustment
TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.
Tap “Next”. Date & time current recorded in DLU Tap “Date”.
will display. If you have to adjust, tap
“Change”, if no need to change, tap
“Set”.
(19) Date & Time adjustment (20) Date & Time adjustment (21) Date & Time adjustment
Tap “Today”. Date & year will set Tap “Time”. Tap hour and adjust to local by
automatically. Before setting date, tapping “ ” “ ”.
confirm date on Palm is same as
local.
6. Code “SAI-P” –6/9
(22) Date & Time adjustment (23) Date & Time adjustment (24) Date & Time adjustment
Tap minute and adjust to local by Tap minute and adjust to local by If date & time are same as local, tap
tapping “ ” “ ”. tapping “ ” “ ”. “Set”.
(25) Date & Time adjustment (26) Service meter adjustment (27) Service meter adjustment
Message will display. Tap “Ok” to set Main screen Tap menu icon.
date & time. Tap “Back” to correct
date & time.
6. Code “SAI-P” –7/9
(28) Service meter adjustment (29) Service meter adjustment
TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.
(30) Service meter adjustment (31) Service meter adjustment (32) Service meter adjustment
Tap “Next”. If service meter reading is not match Tap “ ” “ ”, and adjust service
to equipment, tap “Change”. meter reading to actual equipment.
6. Code “SAI-P” –8/9
(33) Service meter adjustment (34) Service meter adjustment (35) Confirmation
Tap menu icon. Tap “SystemCheck” in tools menu. Confirm every information on this
screen are correct. If not, please
re-adjust.
6. Code “SAI-P” –9/9
7. Code “DDL-P” –1/5
When perform this code
Perform this code, when you attempt to download monitoring data from equipment
NOTE
Downloaded data will belong to
customer. Shall not disclose data to
third parties, or to even internal
personnel, if they aren’t authorized.
7. Code “DDL-P” –2/5
(01) Enter name (02) Set time difference
TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.
Tap name column, and enter name Tap “ ” to set time difference
who attempt to download. If you between GMT. List of time difference
already registered, tap “ ” to find is at Code “DDLP” –3/5.
your name.
Do not terminate palm application Do not change key switch to any Do not disconnect cables while
while downloading. Otherwise data position while downloading. downloading. Otherwise data will
will corrupt. Otherwise data will corrupt. corrupt.
7. Code “DDL-P” –5/5
Errors
If any error occurred, please take following procedure, and retry download.
Turn key switch to off Disconnect download Quit tools running on Connect cable to
position. cables. Palm. equipment.
TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.
Tap “Ok”.
9. Code “SEC-P” –1/4
When perform this code
Perform this code, when you want to check communication line between sensor to controller.
(04) Sensor communication check (05) Sensor communication check (06) Sensor communication check
System check main screen. Tap menu icon. Select “Condition” in system check
menu.
9. Code “SEC-P” –3/4
(07) Sensor communication check (08) Sensor communication check (09) Sensor communication check
Equipment conditions will display/ Tap menu icon. Select “Sensor Fault” in system check
Check figure(s) will change while menu.
operating. Information will vary by
equipment models.
O = Equip on equipment
NA = Not available on equipment
10. Code “CEC-P” –1/3
When perform this code
Perform this code, when you want to check communication line between controller and DLU..
System check main screen. Tap menu icon. Select “Condition” in system check
menu.
10. Code “SEC-P” –3/3
(07) Communication condition