Diagnostic / Monitoring / Adjusting tools for following excavators.
Hitachi EX-1 (550), EX-3 (400 to 600), EX-5 (400 to 800), ZAXIS (450 to 850)
Fiat Hitachi FH450-3, EX455, EX456

EPVC_Mid
Diagnostic / Monitoring / Adjusting tools for following excavators.
Hitachi EX-1 (USE series), EX-2 (60 to 300), EX-3 (60 to 310) EX-5 (60 to 370), ZAXIS (70 to 380)
Fiat Hitachi FH-2 series, FH-3 series, EX series (less than 40 tons)

EPVC_Mini
Diagnostic / Monitoring / Adjusting tools for following excavators.
Hitachi EX33Mu & EX58Mu

HMS_LargeMid
Monitoring data download / Data logger setting following excavators.
Hitachi ZAXIS (70 to 850)
John Deere C series (80C to 800C)

MIC_Mining
Monitoring data download / Data logger setting / Monitoring / Diagnostic following excavators.
Hitachi EX1200-5/5C, EX1900-5, EX2500-1/5, EX3500-1/2/3, EX3600-5, EX5500-5
EPVC_LARGE
Operation Manual

Hitachi Construction Machinery Co. Ltd.

NOTE
This manual is based on Hitachi ZX series. Screen / Function /
Procedure are vary by model.
1. Necessary Tools & Cable Connection
2. MODE
OPERATION MODE
3. Operation Mode – How to Start Dr.ZX with Operation Mode
4. Operation Mode – Self-Diagnostic
5. Operation Mode – Monitoring
6. Operation Mode – Special Function (WU Deactivation)
7. Operation Mode – Special Function (ECO Deactivation)
8. Operation Mode – Special Function (Pump Adjustment)

SERVICE MODE
9. Service Mode – How to Start Dr.ZX with Service Mode
10. Service Mode – Learning Data Display
11. Service Mode – Monitor Panel LCD Control
12. Service Mode – Parameter Change
13. Service Mode – Act/Deact of Parameters

STAND ALONE MODE


14. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode
15. Stand Alone Mode – Change Password
16. Stand Alone Mode – View Manuals
17. Stand Alone Mode – Play Recorded Data
1. Necessary Tools & Cable Connection
Necessary tools

(a) Palm OS PDA (b) Serial cable (c) Dr.ZX communication cable

Dr.ZX must be installed. Hitachi For SONY Clie PEG-TJ25 This is Hitachi unique part. Make an
recommends following models. Purchase from CPD. P/no. is order to your parts ordering channel.
SONY 4629330 (Hitachi unique Hitachi part no. is 4476512.
Clie PEG-TJ25 parts).
PalmOne Inc. For PalmOne PDAs
m125 / 130 / 500 / 505 / 515 Purchase from local market.
Tungsten T2 / T3 / C Product name is HotSync serial

Cable connection

Dr.ZX cable Serial cable Palm OS PDA Palm

Serial cable

Connect to Dr.ZX cable


Dr.ZX
connector.
Equipment
2. Mode

Self-Diagnostic Start Dr.ZX with


EPVC_Large Monitoring / Recording Sensor out-put signal Operation Mode
WU (Warming-up function) Deactivation
NOTE ECO (Economy function) Deactivation
For non-current models (such Pump (Angle sensor) Adjustment
as EX-2/-3/-5), operation &
stand-alone mode will apply

Check Engine Learning Data Start Dr.ZX with


Monitor Engine Speed & Hydraulic Oil Temperature Service Mode.
Change Parameter(s), such as follows
Engine RPM
Auto-Lub. Interval
Pump Max. Displacement
Pump Max. Torque
Pump Cut-off Pressure
Activate or Deactivate Changed Parameters

Change Password Stand-alone


Replay Recorded Monitoring Data Mode (No need
Refer Instant Operation Manual to hock up with
equipment)
3. Operation Mode – How to Start Dr.ZX with Operation Mode (1/4)

Turn key switch Check engine Connect Dr.ZX to Turn key switch Switch on Palm.
“OFF”. learning switch is equipment. “ON”.
OFF.

Start Dr.ZX. Select Start operation Operation mode Self - Diagnostic


“EPVC_Large”. mode. menu.

Monitoring
View / Recording

Special Function
3. Operation Mode – How to Start Dr.ZX with Operation Mode (2/4)
(a) Turn key switch “OFF” (b) Check Engine learning switch is OFF

Fuse box

OFF

Stamp

(c) Connect Dr.ZX to equipment.


3. Operation Mode – How to Start Dr.ZX with Operation Mode (3/4)
(d) Turn key switch “ON” (e) Switch “ON” Palm (f) Start Dr.ZX

Main switch is vary by Palm model. Tap “Dr.ZX” icon on Palm.


Above shows Palm m500 / 505 / 515.

(g) Select “EPVC_Large”. (h) Start operation mode (i) Model / Version information

Tap “ ” of EPVC_Large. Tap “START”. Check model. If model is correct, tap


“correct”, if not tap “ESC” and contact
to your dealer.
3. Operation Mode – How to Start Dr.ZX with Operation Mode (4/4)
(j) Operation mode main menu
4. Operation Mode – Self-Diagnostic (1/3)

Start Dr.ZX with Select No error Message will


Operation mode. “Self-diagnostic”. detected. display.

Error(s) are Error code(s) will Tap “ESC”. Carry out


detected. display. “Retry”.

No error Message will


detected. display.

Still error(s) are Error code(s) will Tap “Details” for


detected display. check detail of
each error code.
4. Operation Mode – Self-Diagnostic (2/3)
(a) Start self-diagnostic (b) No error detected

Tap “ ” of Self-Diagnostic. If Dr.ZX could not detect any error(s),


above message will display. Tap
“ESC”.

(c) Error(s) detected (d) Retry (e) No error detected

Error code(s) that detected will Tap “Retry B” for retrying. If Dr.ZX could not detect any error(s),
display to Palm. Tap “ESC” for retry. above message will display. Tap
“ESC”.
4. Operation Mode – Self-Diagnostic (3/3)
(f) Still error(s) detected (g) Explanation of each code (h) Explanation of each code

If Dr.ZX still detect any error(s) , error Message will show meanings of each Tap “ESC” fir quit self-diagnostic.
code(s) will display. Tap “Details” for code, and corrective action. Tap
check error(s). “Next” for view additional information
or other code. NOTE
Refer service manuals for
troubleshooting.
5. Operation Mode – Monitoring (1/5)

Operation mode Select Monitor Enter model Select item. Start monitoring.
menu. display. code & serial no. (Max. four items)

Start recording. Select data bank If data bank isn’t Write recorded Enter comment if
that store empty, Dr.ZX will data to data you want.
recorded data. ask overwrite. bank.

NOTE
If you did not enter model code & equipment
serial no., you can’t record monitoring data to
Palm.
5. Operation Mode – Monitoring (2/5)
(a) Start Monitoring (b) Enter model code & s/no.

TIP
You can use keyboard to enter
model code & serial no. by tap
“abc” or “123” on GRAFFITI area.
Tap “ ” of Monitor Display Tap columns and enter model code &
serial no. If you did not enter model
code & serial no., you can’t record
monitoring data.

Selected item Item


(c) Tap “OK” (d) Select monitoring item(s)
changeover
button

After enter model & serial no., tap Tap “ ” of item you want monitor. You
“OK”. If you don’t need to record can monitor four items in once.
Number of
monitoring data, no need to enter Clear selected
selected item(s).
model code & serial no. Just tap “OK”. item(s).
5. Operation Mode – Monitoring (3/5)
(e) Start display data (f) Start display monitoring data

After selecting item(s), tap “Start” for Item(s) will display. Screen will vary
display monitoring data. by selected items. Tap “Hold” for
pause data. If you want quit, tap
“ESC”.

(g) Start Recording (h) Recording

NOTE
If you did not enter
Tap “Record” for record monitoring During recording, above screen will
model code & serial no.,
data. Dr.ZX will record data for three display.
“Record” button shall
(3) seconds.
not appear.
5. Operation Mode – Monitoring (4/5)
(i) Select data bank (j) Data bank is not empty (k) Data bank is empty

Tap data bank (figure) that you want If selected data bank already has If selected data bank is empty, above
to store recorded data. data, above screen will appear. Tap screen will display. Tap “Write” for
“OverWrite” for store recorded data, store recorded monitoring data.
tap “ESC” for back to previous menu.

(l) Confirmation (l) Enter comment TIP


You can use keyboard to enter
comment. Tap “abc” on GRAFFITI
are.

After data stored, confirmation screen Tap comment column, and enter
NOTE
will display. Tap “ESC” to quit, or if comment. After entering, tap “OK”.
Click here for how to repaly
you want enter comment, tap
recorded data.
“Comment”.
5. Operation Mode – Monitoring (5/5)
Items can be monitored (vary by model)
6. Operation Mode – Special Function (WU Deactivation –1/2)

Select Special Special function Select WU Execute WU has


Function. menu Deactivation deactivated.

WU Function.
WU stands for Warming-Up. This function is, when start engine while hydraulic oil
temperature is less than zero (0) Celsius, computer will increase low idle rpm for warm
hydraulic oil quickly.
6. Operation Mode – Special Function (WU Deactivation –2/2)
(a) Select special function (b) Select WU deactivation (c) Select WU deactivation

Tap “ ” of Special Function. Tap “ ” of WU Deactivation.. Tap “Execute for Deactivation. If you
want back to previous menu, tap
“ESC”.

(d) Confirmation

After deactivation, above message NOTE


will display. Tap ”ESC” for quit. WU (Warming-up function) will
re-activate when key switch is
turned “OFF”.
7. Operation Mode – Special Function (ECO Deactivation –1/2)

Select Special Special function Select ECO Execute ECO has


Function. menu Deactivation deactivated.

ECO Function
ECO stands for ECOnomy. This function is, when all levers are in neutral position,
computer will reduce engine rpm to 1600min-1 gradually. If any lever(s) are operated, engine
rpm will back.
7. Operation Mode – Special Function (ECO Deactivation –2/2)
(a) Select special function (b) Select ECO deactivation (c) Select WU deactivation

Tap “ ” of Special Function. Tap “ ” of ECO Deactivation.. Tap “Execute for Deactivation. If you
want back to previous menu, tap
“ESC”.

(d) Confirmation

After deactivation, above message NOTE


will display. Tap ”ESC” for quit. ECO (Economy function) will
re-activate when key switch is
turned “OFF”.
8. Operation Mode – Special Function (Pump Adjustment –1/9)

Switch OFF Turn key switch Remove both Confirm sensors Check engine
Palm. “OFF”. angle sensors are connecting to learning switch is
from pump. harness. OFF.

Connect Dr.ZX to Start engine. Confirm engine Switch on Palm. Start Dr.ZX.
equipment. is running with
low idle.

Start Start operation Operation mode


“EPVC_Large”. mode. menu. Continue to next page.
8. Operation Mode – Special Function (Pump Adjustment –2/9)

Select “Special Select “Max. Wait more than Adjust sensor


From Function”. Disp. Holding”. five (5) seconds. shaft.
previous

Apply a film of Install angle Adjust angle Tighten bolts &


grease. sensors to pump. sensors. washers.
8. Operation Mode – Special Function (Pump Adjustment –3/9)
(a) Switch off Palm (b) Turn key switch off

Main switch is vary by Palm model.


Above shows Palm m500 / 505 / 515.

(c) Remove A (angle) sensors from pump


Engine
Loose Pump-2 Pump-1
Bolts sensor sensor

Pump-2 Pump-1
sensor sensor
Remove two (2) angle sensors from
pump. When removing, take care not
to lose internal spacer & fastener
ZX450 & ZX500 ZX600 & ZX800
spring.
8. Operation Mode – Special Function (Pump Adjustment –4/9)
(d) Confirm connection (e) Check Engine learning switch is OFF
Fuse box

Connect to OFF
harness

Confirm sensors are connecting to


harness.

Stamp

(f) Confirm Dr.ZX is connecting to equipment.


8. Operation Mode – Special Function (Pump Adjustment –5/9)
(g) Start engine (h) Run engine at low idle (i) Switch on Palm

Confirm engine control dial position Main switch is vary by Palm model.
lowest engine speed. Above shows Palm m500 / 505 / 515.

(j) Start Dr.ZX (k) Select “EPVC_Large”. (l) Start operation mode

Tap “Dr.ZX” icon on Palm. Tap “ ” of EPVC_Large. Tap “START”.


8. Operation Mode – Special Function (Pump Adjustment –6/9)
(m) Model / Version information (n) Select special function (o) Select pump adjustment

Check model. If model is correct, tap Tap “ ” of Special Function. Tap “ ” of pump adjustment.
“correct”, if not tap “ESC” and contact
to Hitachi.

(p) Select Max. Disp. Holding (q) Sensor signal displayed

NOTE
After tap “Max. Disp.
Holding”, wait more than
Tap “ ” of pump adjustment. five (5) seconds. Computer Return signals (voltage) from angle
will operate main pump to sensors will display.
maximum displacement
position.
8. Operation Mode – Special Function (Pump Adjustment –7/9)
(r) Adjust sensor shaft

With the punch mark on the angel sensor shaft, towards the A Sensor Main pump
opposites side of the harness, and adjust (turn) shaft that
signal voltage is as following specification.

ZX450 & ZX500


Pump-1 angle sensor; 1.60V
Pump-2 angle sensor; 3.40V
Punch Feedback
Mark Shaft
ZX600 & ZX800
Pump-1 angle sensor: 1.60V
Pump-2 angle sensor; 1.60V

(s) Apply grease

Apply a film of grease to the surface of fastener


spring, and install It into the cavity on the feedback Fastener
shaft. Spring
8. Operation Mode – Special Function (Pump Adjustment –8/9)
(s) Adjust sensors

Install sensors to main pump. Set signal voltage as following specifications,


by adjusting the holes of A (angle) sensor.

ZX450 & ZX500


Pump-1 angle sensor; 1.60V +0.02/-0.02
Pump-2 angle sensor; 3.40V +0.02/-0.02

ZX600 & 800


Pump-1 angle sensor; 1.60V +0.02/-0.02
Pump-2 angle sensor; 1.60V +0.02/-0.02

ZX450 & ZX500 Angle Sensors Location ZX450 & ZX500 Angle Sensors Location

Pump-2 Pump-1 Engine


sensor sensor

Pump-2 Pump-1
sensor sensor

Harness Harness
Side Side Harness Harness
Side Side
8. Operation Mode – Special Function (Pump Adjustment –9/9)
(t) Tighten bolts (u) Quit pump adjustment

Tighten bolts &


washers.

Tap “ESC” for quit pump adjustment.


Tighten bolts & washers to 9.8Nm (1.0
kgf-m, 7.2 lbf-ft).
9. Service Mode – How to Start Dr.ZX with Service Mode (1/4)

Turn key switch Wait more than Connect Dr.ZX to Switch on the Turn key switch
“OFF”. ten(10) seconds. equipment. engine-learning “ON”.
switch.

Switch on Palm. Start Dr.ZX. Select Start service Confirm model.


“EPVC_Large”. mode.

Confirm current Select Special Service mode Check Engine Learning Data
Dr.ZX mode. function. menu.

Monitor Panel LCD (Liquid Crystal Display) Control

Change Parameter.

Activate or Deactivate Changed Parameters


9. Service Mode – How to Start Dr.ZX with Service Mode (2/4)
(a) Turn key switch “OFF” (b) Switch on Engine-learning switch

Fuse box

NOTE
Wait more than ten (10) ON
seconds, after key
switch is turned off.

Stamp

(c) Connect Dr.ZX to equipment.


9. Service Mode – How to Start Dr.ZX with Service Mode (3/4)
(d) Turn key switch “ON” (e) Switch “ON” Palm (f) Start Dr.ZX

NOTE
Main switch is vary by Palm model. Tap “Dr.ZX” icon on Palm.
Shall not start engine.
Above shows Palm m500 / 505 / 515.

(g) Select “EPVC_Large” (h) Start service mode (i) Model / Version information

Tap “ ” of EPVC_Large. Tap “START”. Check model. If model is correct, tap


“correct”, if not tap “ESC” and contact
to Hitachi.
9. Service Mode – How to Start Dr.ZX with Service Mode (4/4)
(j) Service mode confirmation (k) Select “Special Function” (l) Service mode menu

Tap “Rechecked”. Tap “ ” of “Special Function”.


10. Service Mode – Learning Data Display (1/2)
Data shows EC motor position when engine stop or engine running on maximum speed.

Service mode Select “Learning Select “Engine Position will


menu. Data Display”. Stop Position”. display.

Select “Engine Position will


Stop Position”. display/.
10. Service Mode – Learning Data Display (2/2)
(a) Select “Learning Data Display”. (b) Select item (c) Engine stop position

Tap “ ” of “Learning Data Display” in Tap “ ” of item you want to view. EC Motor position will display. Tap
service mode menu. “ESC” for quit.

(c) Engine max. speed position

EC Motor position will display. Tap


“ESC” for quit.
11. Service Mode – Monitor Panel LCD Control (1/2)
This function is able or disable to display actual engine speed and/or hydraulic oil temperature on monitor panel LCD( Liquid
Crystal Display).

LCD Display Select


(Liquid Crystal Display) Switch
This switch will changeover

Monitor Panel

Service mode Select “Monitor Select “Engine Select “display” Select “Execute”.
menu. Display”. Actual Speed”. or “not to
display”.

Select “Hydraulic Select “display” Select “Execute”.


Oil Temp.”. or “not to
display”.
11. Service Mode – Monitor Panel LCD Control (2/2)
(a) Select “Monitor Display”. (b) Select item (c) Select control

Tap “ ” of “Monitor Display” in Tap “ ” of item you want to view on Tap “Disp” for allow to display
service mode menu. monitor panel. information, and tap “NoDisp” for not
allow to display information.

(c) Execute (c) Quit

Tap “Execute” for activate control. If execution is completed, above


message will display. Tap “ESC” for
quit.
12. Service Mode – Parameter Change (1/4)
Please click here for view items can be changed parameters.

Service mode Select Select item. Enter parameter. Select “Execute”.


menu. “Parameter
Change”.

Confirmation Tap “Execute”. End message. Tap “ESC”.


screen.

NOTE
You have to carry out “Act/Deact of Parameters”
function after changing parameters. Otherwise
changed parameter(s) shall not transfer to
equipment main computer.
12. Service Mode – Parameter Change (2/4)
(a) Select “Parameter Change” (b) Select item

Tap “ ” or “ ” to
changeover items.

Tap “ ” of “Parameter Change” in Tap “ ” of item you want to view.


service mode menu.

(c) Enter figures (c) Tap “Execution”

TIP
You can use keyboard to enter
figures. Tap “123” on GRAFFITI
are.
Tap entering column, and enter
figures to be adjusted.
12. Service Mode – Parameter Change (3/4)
(c) Confirmation screen (c) Quit

Confirmation screen will display. If Tap “ESC” to quit.


figures are correct, tap “Execute”.
12. Service Mode – Parameter Change (4/4)
Items can be changed parameters (vary by model)
13. Service Mode – Act/Deact of Parameters (1/2)

Service mode Select Tap “Act”. Changed


menu. “Act/Deact of parameter(s) will
Parameters“. reflect to
computer.

Tap “Deact”. Will deact


changed
parameter(s) in
computer
13. Service Mode – Act/Deact of Parameters (2/2)
(a) Select “Parameter Change” (b) Select “Act” or “Deact”. (c-1) Activation

Tap “ ” of “Parameter Change” in Select activation or Tap “Execute”, and tap “ESC” to quit.
service mode menu. deactivation.

(c-1) Deactivation

Tap “Execute”, and tap “ESC” to quit.


14. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (1/2)

Switch on Palm. Start Dr.ZX. Start Main screen. Change password


“EPVC_Large”.

View manuals.

Play recorded
monitoring data.
14. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (2/2)
(a) Switch “ON” Palm (b) Start Dr.ZX

Main switch is vary by Palm model. NOTE Tap “Dr.ZX” icon on Palm.
Above shows Palm m500 / 505 / 515. No need to hook up
with equipment.

(c) Select “EPVC_Large” (d) Main screen

Tap “ ” of EPVC_Large.
15. Stand Alone Mode – Change Password (1/3)

Main screen. Tap “Password”. Enter current Enter new Re-enter new
password. password. password.

New password NOTE


will apply. New password will apply to
all Dr.ZX function.
15. Stand Alone Mode – Change Password (2/3)
(a) Main screen (b) Enter current password

TIP
You can use keyboard to enter
password. Tap “abc” on GRAFFITI
are.

Tap “Password”. Enter current password. Default


password is zx2000.

(c) Tap “Execute” (d) Enter new password (e) Tap “Execute”
15. Stand Alone Mode – Change Password (3/3)
(f) Re-enter new password (g) Tap “Execute” (h) Tap “ESC”

Password has been changed.


16. Stand Alone Mode – View Manuals (1/2)

Main screen. Tap “Op Manual”. Select Manual. View operation


mode manual.

View service
mode manual.

View engine
learning mode
manual.
16. Stand Alone Mode – View Manuals (2/2)
(a) Main screen (b) Select Manual

Tap ”Op. Manual”. Tap “ ” of mode that you want to


view manual.

(c) Operation mode manual (d) Service mode manual (e) Engine learning mode manual

Tap “ESC” to quit.


17. Stand Alone Mode – Play Recorded Data (1/2)

Main screen. Tap “Record Select data bank. Play recorded


Disp”. data.

NOTE
To play recoded data, you have to record monitoring
data before.
17. Stand Alone Mode – Play Recorded Data (2/2)
(a) Main screen (b) Select data bank (c) Recoded data

Tap ”Record Disp”. Tap number of data bank that you Recorded monitoring data will display.
want to play, and tap “Play Back”. Tap “ESC” to quit.
EPVC_MID
Operation Manual

Hitachi Construction Machinery Co. Ltd.

NOTE
This manual is based on Hitachi ZX series. Screen / Function /
Procedure are vary by model.
1. Necessary Tools & Cable Connection
2. MODE
OPERATION MODE
3. Operation Mode – How to Start Dr.ZX with Operation Mode
4. Operation Mode – Self-Diagnostic
5. Operation Mode – Monitoring
6. Operation Mode – Special Function (WU Deactivation)
7. Operation Mode – Special Function (ECO Deactivation)

SERVICE MODE
8. Service Mode – How to Start Dr.ZX with Service Mode
9. Service Mode – Learning Data Display
10. Service Mode – Monitor Panel LCD Control
11. Service Mode – Parameter Change

STAND ALONE MODE


12. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode
13. Stand Alone Mode – Change Password
14. Stand Alone Mode – View Manuals
15. Stand Alone Mode – Play Recorded Data
1. Necessary Tools & Cable Connection
Necessary tools

(a) Palm OS PDA (b) Serial cable (c) Dr.ZX communication cable

Dr.ZX must be installed. Hitachi For SONY Clie PEG-TJ25 This is Hitachi unique part. Make an
recommends following models. Purchase from CPD. P/no. is order to your parts ordering channel.
SONY 4629330 (Hitachi unique Hitachi part no. is 4476512.
Clie PEG-TJ25 parts).
PalmOne Inc. For PalmOne PDAs
m125 / 130 / 500 / 505 / 515 Purchase from local market.
Tungsten T2 / T3 / C Product name is HotSync serial

Cable connection

Dr.ZX cable Serial cable Palm OS PDA Palm

Serial cable

Connect to Dr.ZX cable


Dr.ZX
connector.
Equipment
2. MODE

Self-Diagnostic Start Dr.ZX with


Dr.ZX Monitoring / Recording Sensor out-put signal Operation Mode
WU (Warming-up function) Deactivation
NOTE ECO (Economy function) Deactivation
For non-current models (such
as EX-2/-3/-5), operation &
stand-alone mode will apply

Check Engine Learning Data Start Dr.ZX with


Monitor Engine Speed & Hydraulic Oil Temperature Service Mode.
Change Parameter(s), such as follows
Engine RPM
Auto-Lub. Interval
Pump Max. Displacement
Pump Max. Torque
Pump Cut-off Pressure

Change Password Stand-alone


Replay Recorded Monitoring Data Mode (No need
Refer Instant Operation Manual to hock up with
equipment)
3. Operation Mode – How to Start Dr.ZX with Operation Mode (1/5)

Turn key switch Check engine Connect Dr.ZX to Turn key switch Switch on Palm.
“OFF”. learning switch is equipment. “ON”.
OFF.

Start Dr.ZX. Select Start operation Operation mode Self - Diagnostic


“EPVC_Mid”. mode. menu.

Monitoring
View / Recording

Special Function
3. Operation Mode – How to Start Dr.ZX with Operation (2/5)
(a) Turn key switch “OFF” (b) Check Engine learning switch is OFF

Stamp

Hitachi ZAXIS110 & up

Hitachi ZAXIS70, 80, 75US,


75UR, 135US, 225US
3. Operation Mode – How to Start Dr.ZX with Operation (3/5)
(c) Connect Dr.ZX to equipment.

Hitachi ZAXIS110 & up

Hitachi ZAXIS70, 80, 75US,


75UR, 135US, 225US
3. Operation Mode – How to Start Dr.ZX with Operation Mode (4/5)
(d) Turn key switch “ON” (e) Switch “ON” Palm (f) Start Dr.ZX

Main switch is vary by Palm model. Tap “Dr.ZX” icon on Palm.


Above shows Palm m500 / 505 / 515.

(g) Select “EPVC_Mid” (h) Start operation mode (i) Model / Version information

Tap “ ” of EPVC_Mid. Tap “START”. Check model. If model is correct, tap


“correct”, if not tap “ESC” and contact
to your dealer.
3. Operation Mode – How to Start Dr.ZX with Operation Mode (5/5)
(j) Operation mode main menu
4. Operation Mode – Self-Diagnostic (1/3)

Start Dr.ZX with Select No error Message will


Operation mode. “Self-diagnostic”. detected. display.

Error(s) are Error code(s) will Tap “ESC”. Carry out


detected. display. “Retry”.

No error Message will


detected. display.

Still error(s) are Error code(s) will Tap “Details” for


detected display. check detail of
each error code.
4. Operation Mode – Self-Diagnostic (2/3)
(a) Start self-diagnostic (b) No error detected

Tap “ ” of Self-Diagnostic. If Dr.ZX could not detect any error(s),


above message will display. Tap
“ESC”.

(c) Error(s) detected (d) Retry (e) No error detected

Error code(s) that detected will Tap “Retry B” for retrying. If Dr.ZX could not detect any error(s),
display to Palm. Tap “ESC” for retry. above message will display. Tap
“ESC”.
4. Operation Mode – Self-Diagnostic (3/3)
(f) Still error(s) detected (g) Explanation of each code (h) Explanation of each code

If Dr.ZX still detect any error(s) , error Message will show meanings of each Tap “ESC” fir quit self-diagnostic.
code(s) will display. Tap “Details” for code, and corrective action. Tap
check error(s). “Next” for view additional information
or other code. NOTE
Refer service manuals for
troubleshooting.
5. Operation Mode – Monitoring (1/5)

Operation mode Select Monitor Enter model Select item. Start monitoring.
menu. display. code & serial no. (Max. four items)

Start recording. Select data bank If data bank isn’t Write recorded Enter comment if
that store empty, Dr.ZX will data to data you want.
recorded data. ask overwrite. bank.

NOTE
If you did not enter model code & equipment
serial no., you can’t record monitoring data to
Palm.
5. Operation Mode – Monitoring (2/5)
(a) Start Monitoring (b) Enter model code & s/no.

TIP
You can use keyboard to enter
model code & serial no. by tap
“abc” or “123” on GRAFFITI area.
Tap “ ” of Monitor Display Tap columns and enter model code &
serial no. If you did not enter model
code & serial no., you can’t record
monitoring data.

Selected item Item


(c) Tap “OK” (d) Select monitoring item(s)
changeover
button

After enter model & serial no., tap Tap “ ” of item you want monitor. You
“OK”. If you don’t need to record can monitor four items in once.
Number of
monitoring data, no need to enter Clear selected
selected item(s).
model code & serial no. Just tap “OK”. item(s).
5. Operation Mode – Monitoring (3/5)
(e) Start display data (f) Start display monitoring data

After selecting item(s), tap “Start” for Item(s) will display. Screen will vary
display monitoring data. by selected items. Tap “Hold” for
pause data. If you want quit, tap
“ESC”.

(g) Start Recording (h) Recording

NOTE
If you did not enter
Tap “Record” for record monitoring During recording, above screen will
model code & serial no.,
data. Dr.ZX will record data for three display.
“Record” button shall
(3) seconds.
not appear.
5. Operation Mode – Monitoring (4/5)
(i) Select data bank (j) Data bank is not empty (k) Data bank is empty

Tap data bank (figure) that you want If selected data bank already has If selected data bank is empty, above
to store recorded data. data, above screen will appear. Tap screen will display. Tap “Write” for
“OverWrite” for store recorded data, store recorded monitoring data.
tap “ESC” for back to previous menu.

(l) Confirmation (l) Enter comment TIP


You can use keyboard to enter
comment. Tap “abc” on GRAFFITI
are.

After data stored, confirmation screen Tap comment column, and enter
NOTE
will display. Tap “ESC” for quit, or if comment. After entering, tap “OK”.
Click here for how to replay
you want enter comment, tap
recorded data.
“Comment”.
5. Operation Mode – Monitoring (5/5)
Items can be monitored (vary by model)
6. Operation Mode – Special Function (WU Deactivation –1/2)

Select Special Special function Select WU Execute WU has


Function. menu Deactivation deactivated.

WU Function.
WU stands for Warming-Up. This function is, when start engine while hydraulic oil
temperature is less than zero (0) Celsius, computer will increase low idle rpm for warm
hydraulic oil quickly.
6. Operation Mode – Special Function (WU Deactivation –2/2)
(a) Select special function (b) Select WU deactivation (c) Select WU deactivation

Tap “ ” of Special Function. Tap “ ” of WU Deactivation.. Tap “Execute for Deactivation. If you
want back to previous menu, tap
“ESC”.

(d) Confirmation

After deactivation, above message NOTE


will display. Tap ”ESC” for quit. WU (Warming-up function) will
re-activate when key switch is
turned “OFF”.
7. Operation Mode – Special Function (ECO Deactivation –1/2)

Select Special Special function Select ECO Execute


ECO has
Function. menu Deactivation
deactivated.

ECO Function
ECO stands for ECOnomy. This function is, when all levers are in neutral position,
computer will reduce engine rpm to 1600min-1 gradually. If any lever(s) are operated, engine
rpm will back.
7. Operation Mode – Special Function (ECO Deactivation –2/2)
(a) Select special function (b) Select ECO deactivation (c) Select WU deactivation

Tap “ ” of Special Function. Tap “ ” of ECO Deactivation.. Tap “Execute for Deactivation. If you
want back to previous menu, tap
“ESC”.

(d) Confirmation

After deactivation, above message NOTE


will display. Tap ”ESC” for quit. ECO (Economy function) will
re-activate when key switch is
turned “OFF”.
8. Service Mode – How to Start Dr.ZX with Service Mode (1/5)

Turn key switch Wait more than Connect Dr.ZX to Switch on the Turn key switch
“OFF”. ten(10) seconds. equipment. engine-learning “ON”.
switch.

Switch on Palm. Start Dr.ZX. Select Start service Confirm model.


“EPVC_Mid”. mode.

Confirm current Select Special Service mode Check Engine Learning Data
Dr.ZX mode. function. menu.

Monitor Panel LCD (Liquid Crystal Display) Control

Change Parameter.

Activate or Deactivate Changed Parameters


8. Service Mode – How to Start Dr.ZX with Service Mode (2/5)
(a) Turn key switch “OFF” (b) Switch on the Engine-learning switch

Stamp

NOTE
Wait more than ten (10)
ZX110 & up, 120C & up
seconds, after key
switch is turned off.

ZX70/80/75US/75UR & 80C


8. Service Mode – How to Start Dr.ZX with Service Mode (3/5)
(c) Connect Dr.ZX to equipment.

Hitachi ZAXIS110 & up

Hitachi ZAXIS70, 80, 75US,


75UR, 135US, 225US
8. Service Mode – How to Start Dr.ZX with Service Mode (4/5)
(d) Turn key switch “ON” (e) Switch “ON” Palm (f) Start Dr.ZX

NOTE
Main switch is vary by Palm model. Tap “Dr.ZX” icon on Palm.
Shall not start engine.
Above shows Palm m500 / 505 / 515.

(g) Select “EPVC_Large” (h) Start service mode (i) Model / Version information

Tap “ ” of EPVC_Mid. Tap “START”. Check model. If model is correct, tap


“correct”, if not tap “ESC” and contact
to Hitachi.
8. Service Mode – How to Start Dr.ZX with Service Mode (5/5)
(j) Service mode confirmation (k) Select “Special Function” (l) Service mode menu

Tap “Rechecked”. Tap “ ” of “Special Function”.


9. Service Mode – Learning Data Display (1/2)
Data shows EC motor position when engine stop or engine running on maximum speed.

Service mode Select “Learning Select “Engine Position will


menu. Data Display”. Stop Position”. display.

Select “Engine Position will


Stop Position”. display/.
9. Service Mode – Learning Data Display (2/2)
(a) Select “Learning Data Display”. (b) Select item (c) Engine stop position

Tap “ ” of “Learning Data Display” in Tap “ ” of item you want to view. EC Motor position will display. Tap
service mode menu. “ESC” for quit.

NOTE
“Boom Angle Sensor Correction
Value” & “Arm Angle Sensor
Correction Value” are used for
equipment which has lifting load (c) Engine max. speed position
monitor (option item).

EC Motor position will display. Tap


“ESC” for quit.
10. Service Mode – Monitor Panel LCD Control (1/2)
This function is able or disable to display actual engine speed and/or hydraulic oil temperature on monitor panel LCD( Liquid
Crystal Display).

LCD Display Select


(Liquid Crystal Display) Switch
This switch will changeover

Monitor Panel

Service mode Select “Monitor Select “Engine Select “display” Select “Execute”.
menu. Display”. Actual Speed”. or “not to
display”.

Select “Hydraulic Select “display” Select “Execute”.


Oil Temp.”. or “not to
display”.
10. Service Mode – Monitor Panel LCD Control (2/2)
(a) Select “Monitor Display”. (b) Select item
NOTE
“Over Load Alarm” only apply to
equipment which has lifting load
monitor (option).

“Hyd. Oil Filter LED” only applies to


equipment which has high
specification full-flow filter (option)
Tap “ ” of “Monitor Display” in Tap “ ” of item you want to view on
service mode menu. monitor panel.

(c) Select control (c) Execute (c) Quit

Tap “Disp” for allow to display Tap “Execute” for activate control. If execution is completed, above
information, and tap “NoDisp” for not message will display. Tap “ESC” for
allow to display information. quit.
11. Service Mode – Parameter Change (1/4)
Please click here for view items can be changed parameters.

Service mode Select Select item. Enter parameter. Select “Execute”.


menu. “Parameter
Change”.

Confirmation Tap “Execute”. End message. Tap “ESC”.


screen.
11. Service Mode – Parameter Change (2/4)
(a) Select “Parameter Change” (b) Select item

Tap “ ” or “ ” to
changeover items.

Tap “ ” of “Parameter Change” in Tap “ ” of item you want to view.


service mode menu.

(c) Enter figures (d) Tap “Execution”

TIP
You can use keyboard to enter
figures. Tap “123” on GRAFFITI
are.
Tap entering column, and enter
figures to be adjusted.
11. Service Mode – Parameter Change (3/4)
(e) Confirmation screen (f) Quit

Confirmation screen will display. If Tap “ESC” for quit. NOTE


figures are correct, tap “Execute”. Changed parameter will reflect to
computer immediately after quit.
11. Service Mode – Parameter Change (4/4)
Items can be changed parameters (vary by model)
12. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (1/2)

Switch on Palm. Start Dr.ZX. Start Main screen. Change password


“EPVC_Large”.

View manuals.

Play recorded
monitoring data.
12. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (2/2)
(a) Switch “ON” Palm (b) Start Dr.ZX

Main switch is vary by Palm model. NOTE Tap “Dr.ZX” icon on Palm.
Above shows Palm m500 / 505 / 515. No need to hook up
with equipment.

(c) Select “EPVC_Mid” (d) Main screen

Tap “ ” of EPVC_Large.
13. Stand Alone Mode – Change Password (1/3)

Main screen. Tap “Password”. Enter current Enter new Re-enter new
password. password. password.

New password NOTE


will apply. New password will apply to
all Dr.ZX function.
13. Stand Alone Mode – Change Password (2/3)
(a) Main screen (b) Enter current password

TIP
You can use keyboard to enter
password. Tap “abc” on GRAFFITI
are.

Tap “Password”. Enter current password. Default


password is zx2000.

(c) Tap “Execute” (d) Enter new password (e) Tap “Execute”
13. Stand Alone Mode – Change Password (3/3)
(f) Re-enter new passwrod (g) Tap “Execute” (h) Tap “ESC”

Password has been changed.


14. Stand Alone Mode – View Manuals (1/2)

Main screen. Tap “Op Manual”. Select Manual. View operation


mode manual.

View service
mode manual.

View engine
learning mode
manual.
14. Stand Alone Mode – View Manuals (2/2)
(a) Main screen (b) Select Manual

Tap ”Op. Manual”. Tap “ ” of mode that you want to


view manual.

(c) Operation mode manual (d) Service mode manual (e) Engine learning mode manual

Tap “ESC” to quit.


15. Stand Alone Mode – Play Recorded Data (1/2)

Main screen. Tap “Record Select data bank. Play recorded


Disp”. data.

NOTE
To play recoded data, you have to record monitoring
data before.
15. Stand Alone Mode – Play Recorded Data (2/2)
(a) Main screen (b) Select data bank (c) Recoded data

Tap ”Record Disp”. Tap number of data bank that you Recorded monitoring data will display.
want to play, and tap “Play Back”. Tap “ESC” to quit.
EPVC_Mini
Operation Manual

Hitachi Construction Machinery Co. Ltd.

NOTE
This manual is based on Hitachi ZX series. Screen / Function /
Procedure are vary by model.
1. Necessary Tools & Cable Connection
2. Function
3. How to Start EPVC_Mini
4. Displaying & Deleting Fault Code History
5. Troubleshooting
6. Fault Codes List
7. Zone check
8. Monitoring
9. Current Correction
1. Necessary Tools & Cable Connection
Necessary tools

(a) Palm OS PDA (b) Serial cable (c) Dr.ZX communication cable

Dr.ZX must be installed. Hitachi For SONY Clie PEG-TJ25 This is Hitachi unique part. Make an
recommends following models. Purchase from CPD. P/no. is order to your parts ordering channel.
SONY 4629330 (Hitachi unique Hitachi part no. is 4476512.
Clie PEG-TJ25 parts).
PalmOne Inc. For PalmOne PDAs
m125 / 130 / 500 / 505 / 515 Purchase from local market.
Tungsten T2 / T3 / C Product name is HotSync serial

Cable connection

Dr.ZX cable Serial cable Palm OS PDA Palm

Serial cable

Connect to Dr.ZX cable


Dr.ZX
connector.
Equipment
2. Function
EPVC_Mini Fault Code Disp & Del
This function will show or delete fault code & operation history that memorized in
controller. Controller can keep 59 records. If more than 59 fault code and/or operation
occurred, controller would overwrite latest information to oldest record. Computer will

Troubleshooting
This function will display fault code that controller is sensing. If any trouble is
occurring, PDA will shoe fault code. If PDA could not detect any fault, PDA will display
“00” on each items.

ZONE Check
This function will display current boom & swing position.

Monitor Display
This function allows monitoring item. You can check four items in once.

Current Correction
This function allows to correct following items
(a) Boom & swing deceleration currency (adjusting range is +/- 100 mA)
Use this function when you feel deceleration speed is too slow.
(b) Boom stop position (adjusting range is +/- 20 degree)
Use this function when you feel boom stop position it too close or far.
3. How to Start EPVC_Mini -1/3

Turn key switch Connect Dr.ZX to Turn key switch Switch on PDA Start Dr.ZX.
“OFF”. equipment. “ON”.

Kind menu will Main menu will Software version Equipment Main menu will
display. Select display. Select will display. information will display.
“EPVC_Mini”. “Mu” type. Select “Start”. display. Select
“OK”.
3. How to Start EPVC_Mini -2/3
(a) Turn key switch “OFF” (b) Connect cable to equipment (c) Turn key switch “ON”

Remove small oval-shape plastic cap


locate on right side of cab. Pull
connector from hole, and connect
PDA.

(d) Switch on PDA (e) Start Dr.ZX (f) Kind menu

Above shows PalmOne m500. Switch Tap “Dr.ZX” icon. Tap “ ” of “EPVC_Mini”.
location is vary by model.
3. How to Start EPVC_Mini -3/3
(g) Main menu (h) Software version (i) Equipment information

Tap “ ” of “Mu Type”. Tap “Kind Software version will display. Tap Equipment information will display.
Menu” to back to kind menu. “Start” to continue. Tap “Exit” to back Tap “OK” to continue. Tap “Model
to main menu. Menu” to back to software version
display screen.

(j) Item menu

Item menu will display.


4. Displaying & Deleting Fault Code History -1/3
.Select “Fault No fault code are Message will
Code Disp & Del” detected. display.
in item menu.

Fault (s) are Fault code(s) will Tap “Info”. Content of fault
detected. display. will display.

Tap “Delete” All Fault history


will delete.

Tap “Exit” Will Back to item


menu.
4. Displaying & Deleting Fault Code History -2/3
(a) Item menu (b) No faults detected

Tap “ ” of “Fault Code Disp & Del”. If there aren’t any fault recorded in
controller, above message will
display. Tap “Exit” to

(c) Faults detected (e) Check meaning of code (f) Meanings

Fault codes will display (max. 59 Tap “Info.” Meaning of each code will display.
faults). Tap ““ ” or “ ” to Tap ““ ” or “ ” to check other code.
changeover screen. Tap “Exit” to back to fault code list.
4. Displaying & Deleting Fault Code History -3/3
(g) Delete codes (h) Confirmation screen (c) End message

Tap “Delete”. This will clear all fault Tap “Yes” to delete code. Tap “NO” to When clearing is finished, end
code history recording in controller. back to code list. message will display. Tap “OK” to
back to item menu.
5. Troubleshooting
(a) Item menu (b)List of fault codes (c) Check meaning of fault code

Tap “ ” of “Troubleshooting” in item If any faults are occurring, fault code Tap “Info.” to show meaning of each
menu. will display. If no faults are occurring, code. Tap “Exit” to back to item menu.
code will display as “00”. Tap “HOLD”
to check content of fault.

(d) Meaning of fault code

Meaning will display. Tap “Exit” to


back to list of fault code.
6. Fault Codes List
List of Codes
Code Description Code
10 Abnormal CPU condition code register 75 Excessive swing sensor output signal (5V side)
11 Abnormal CPU General Register 80 Abnormal boom angle sensor (0V side)
12 Abnormal CPU mode diagnosis 81 Abnormal swing angle sensor (0V side)
18 Abnormal Interruption test 84 Abnormal boom angle sensor (5V side)
19 Abnormal 16 bit timer (CH1) 85 Abnormal swing angle sensor (5V side)
1A Abnormal 16 bit timer (CH2) A0 Abnormal 12V power voltage (Less than 10V)
1B Abnormal 16 bit timer (CH3) A1 Abnormal 12V power voltage (More than 16V)
1C Abnormal 8 bit timer F0 Initial setting has been done properly
1D Abnormal internal watch dog F1 Deactivate auto boom stop
20 Abnormal RAM read / write F2 Activate auto boom stop
40 Abnormal boom-up solenoid F3 Boom entered to critical zone with deactivating auto boom stop
41 Abnormal swing-right solenoid F4 Boom entered to critical zone with activating auto boom stop
43 Abnormal pilot shut-off relay F5 Boom moved out from critical zone
50 Abnormal boon sensor (0V side) F6 Boom moved doper in the critical zone.
51 Abnormal swing sensor (0V side)
54 Abnormal boon sensor (5V side)
55 Abnormal swing sensor (5V side)
60 Faulty boom sensor initial set value (Lower limit)
62 Faulty swing sensor initial set value (Lower limit)
64 Faulty boom sensor initial set value (Upper limit)
66 Faulty swing sensor initial set value (Upper limit)
70 Excessive boom sensor output signal (0V side)
71 Excessive swing sensor output signal (0V side)
74 Excessive boom sensor output signal (5V side)
7. Zone check -1/3
(a) Item menu (a) Item menu

Tap “ ” of “Zone Check”. Current boom & swing position will


display. Tap “Exit” to back to item
menu.
7. Zone check -2/3
Boom Deceleration / Stop Zone
Max boom up Boom lower

Max. swing
(Right side)

BJL1

BJL2
B1
Right swing

B2 B4 B7

Center swing
Position

BJL3

BJL4

BJL6
Left swing B3 B5 B6
Max. swing
(Left side)

Code Description Code Description


BJL Zone judging line by boom angle. B5 Boom up deceleration zone
B1 Boom up critical zone B6 Boom up normal zone
B2 Boom up stop zone B7 Boom up deceleration zone (Height limit)
B3 Boom up deceleration zone
B4 Boom up deceleration zone (front of operator)
7. Zone check -3/3
Swing Deceleration / Stop Zone
Max boom up Boom lower

Max. swing
S6
(Right side)
Right swing S1
SJL4

SJL5

S2
Center swing
Position S3 SJL2

SJL3

Left swing
S4
Max. swing
(Left side)

Code Description Code Description


BJL Zone judging line by boom angle. S3 Right swing deceleration zone
SJL Zone judging line by swing angle. S4 Right swing deceleration zone
S1 Right swing critical zone S5 Right swing normal zone
S2 Right swing stop zone S6 Right swing deceleration zone (End of right swing)
8. Monitoring
Selected item Item
(a) Item menu (b) Item menu changeover
button

Tap “ ” of “Monitoring Display”. Tap “ ” of item you want monitor. You


can monitor four items in once.
Number of
Clear selected
selected item(s).
item(s).

(c) Start monitoring (d) Monitoring

Tap “Start” to start monitoring. Item(s) that you selected will display
(information will vary by item). Tap
“Hold” to pause data, and tap “Exit” to
quit monitoring.
9. Current Correction –1/2
(a) Item menu (b) Item menu (c) Changing value

Tap “ ” of “Current Correction”. Tap “ ” of item you want change Tap figures you want to change, and
current. tap “OK”. To find figures tap “ ” or “ ”.
If you selected “boom stop position”
unit will be degree.

(d) Confirmation screen (e) Enter password

TIP
You can use keyboard to enter
password. Tap “abc” on GRAFFITI
area.

Confirm figures you changed, and tap To send figures to computer in


“OK”. If you want to correct, tap “Exit”. equipment, you have to enter
password. Tap password area, and
enter “FF”.
9. Current Correction –2/2
(f) Enter password (g) End message

After entering password, tap “OK”. End message will display. Tap “Exit”
to quit.
HMS_LargeMid
Operation Manual

Hitachi Construction Machinery Co. Ltd.

NOTE
This manual is based on Hitachi ZX series. Screen / Function /
Procedure are vary by model.

Downloaded data will belong to customer. Shall not disclose data to


third parties, or to even internal personnel, if they aren’t authorized.
1. Necessary Tools & Cable Connection
2. Function
ICX INITIALIZING
3. ICX Initializing – How to start Dr.ZX
4. ICX Initializing – General Flow
5. ICX Initializing – Set Time Difference from GMT
6. ICX Initializing – Set Local Time
7. ICX Initializing – Synchronize Service-meter
8. ICX Initializing – Model Code & Serial No. Setting

DOWNLOADING
9. Data Downloading – How to Start Dr.ZX
10. Data Downloading – Download
11. Data Downloading – Check Downloaded Data

ICX DIAGNOSIS
12. ICX Self Diagnoses – Flow
13. ICX Self Diagnoses – Operation

CHANGE PASSWORD
14. Change Password – Flow
15. Change Password – Operation
1. Necessary Tools & Cable Connection
Necessary tools

(a) Palm OS PDA (b) Serial cable (c) Dr.ZX communication cable

Dr.ZX must be installed. Hitachi For SONY Clie PEG-TJ25 This is Hitachi unique part. Make an
recommends following models. Purchase from CPD. P/no. is order to your parts ordering channel.
SONY 4629330 (Hitachi unique Hitachi part no. is 4476512.
Clie PEG-TJ25 parts).
PalmOne Inc. For PalmOne PDAs
m125 / 130 / 500 / 505 / 515 Purchase from local market.
Tungsten T2 / T3 / C Product name is HotSync serial

Cable connection

Dr.ZX cable Serial cable Palm OS PDA Palm

Serial cable

Connect to Dr.ZX cable


Dr.ZX
connector.
Equipment
2. Function

ICX Initializing Perform this function when


HMS_LargeMid Set Time Difference from GMT following cases occur.
Set Local Time (a) Deliver new equipment to
NOTE Synchronize Service-Meter Reading customer.
HMS_LargeMid only apply to Set Model Code & Serial No. (b) Replace ICX.
ZX & C series excavators. Clear ICX Internal Memory (c) Error on downloaded data.

Data Downloading Perform this function when you


Data Download want to download data from
Save Data Check equipment.

ICX Self Diagnosis Perform this function when


error(s) on downloaded data.

Change Password Perform this function when you


want to change password.
3. ICX Initializing - How to start Dr.ZX -1/5

Turn key switch Confirm the Connect Dr.ZX to Turn key switch Switch on Palm.
“OFF”. engine-learning equipment. “ON”.
switch is OFF.

Start Dr.ZX. Select Select Select “Set-ICX”. Enter password.


“HMS_LargeMid” “Communication
. Start”.

Tap “Start”. Select “ICX Initial Select


Setting”. “Communication
Start”.
3. ICX Initializing - How to start Dr.ZX -2/5
(a) Turn key switch “OFF” (b) Check Engine learning switch is OFF

Stamp

Hitachi ZAXIS110 & up


John Deere 120C & up

Hitachi ZAXIS70, 80, 75US,


75UR, 135US, 225US
John Deere 80C, 135CRTS,
225CCL RTS
3. ICX Initializing - How to start Dr.ZX -3/5
(c) Connect Dr.ZX to equipment.

Connect
Hitachi ZAXIS110 & up
John Deere 120C & up

Connect

Hitachi ZAXIS70, 80, 75US,


75UR, 135US, 225US
John Deere 80C, 135CRTS,
225CCL RTS
3. ICX Initializing - How to start Dr.ZX -4/5
(d) Turn key switch “ON” (e) Switch “ON” Palm (f) Start Dr.ZX

NOTE
Main switch is vary by Palm model. Tap “Dr.ZX” icon on Palm.
Shall not start engine.
Above shows Palm m500 / 505 / 515.

(g) Select “HMS_LargeMid” (h) Select “Communication Start” (i) Select “Set-ICX”.

Tap “ ” of “HMS_LargeMid”. Tap “ ” of “Communication Start”. Tap “ ” of “Set-ICX”.


3. ICX Initializing - How to start Dr.ZX -5/5
(f) Enter password. (g) Tap “OK”

TIP
You can use keyboard to enter
password. by tap “abc” or “123” on
GRAFFITI area.
Tap entering column, and enter After enter password, tap “OK”.
password. Default password is
zx2000.

(i) Tap “Start” (j) Select “ICX Initial Setting” (j) ICX initializing menu

Tap “ ” of “ICX Initial Setting”. If “ICX


Initial Setting “ is not in menu, tap “ ”
or “ ” to changeover menus.
4. ICX Initializing – General Flow

NOTE
Perform ICX initialization on following cases.
(a) When delivered new equipment to customer.
(b) When replaced ICX.
(c) When error(s) on downloaded data.

Set Set local time. Synchronize Set model code


time-difference service meter & serial no.
from GMT. reading.
5. ICX Initializing – Set Time Difference from GMT -1/2
(a) Select enter Time Diff. from UTC (b) Check current time difference (c) Select time difference

Tap “ ” of “Enter Time Diff. from Check current time difference. If it is Tap up-arrow or down-arrow to find
UTC”. If item is not in menu, tap “ ” correct tap “ESC”, if you want to correct time difference.
or “ ” to changeover menus. correct, tap “Correct”. Time difference
table is on next page.

(d) Set time difference (e) Confirmation screen

If you find correct time difference, tap Tap “OK”


“OK”.
5. ICX Initializing – Set Time Difference from GMT –2/2
6. ICX Initializing – Set Local Time -1/2
(a) Select Enter Date and Time (b) Check local time

NOTE
Please carry out this setting, after
set time difference from GMT.

Tap “ ” of “Enter Date and Time”. . If Check local time. If it is wrong, tap
item is not in menu, tap “ ” or “ ” to “Correct” for correction.
changeover menus.

(c) Correct local time

TIP
You can use keyboard to enter
password. by tap “abc” or “123” on
GRAFFITI area.
Tap entering column and enter
current local time.
6. ICX Initializing – Set Local Time -2/2
(d) Tap “OK” (e) Check local time (f) Confirmation screen

After entering local time, tap “OK”. If local time is correct, tap “OK” for Tap “OK”
set. If not correct, tap “NG” to
re-enter.
7. ICX Initializing – Synchronize Service-meter
(b) Select Hour Meter Setting (c) Check current service meter (d) Confirmation screen

Tap “ ” of “Initial Hour Meter If figures are difference, tap “Set” for Tap “OK”.
Setting”. . If item is not in menu, tap synchronizing. ICX will set it hour
“ ” or “ ” to changeover menus. meter as external hour meter.
8. ICX Initializing – Model Code & Serial No. Setting -1/2
(b) Select Enter Model & Serial no. (c) Tap “OK” (d) Tap “Correct”

Tap “ ” of “Enter Model and Serial Even if model code & Serial no. are
No.”. If item is not in menu, tap “ ” or correct, tap “Correct”.
“ ” to changeover menus.

(e) Enter model code NOTE-1 TIP


If PIN code is “HCM 1G600 L 00123456” You can use keyboard to enter
Model code is 1G6. password. by tap “abc” or “123” on
Serial no. is 123456. GRAFFITI area.

NOTE-2
When entering model code, you have to
add “0” (zero) in front of model code.
If model code and/or serial no. are incorrect,
For example, if model code is 1G6, you
tap column, and enter correct model code
have to enter 01G6.
and/or serial no. Equipment model code &
serial no. are stamp on name plate.
8. ICX Initializing – Model Code & Serial No. Setting -2/2
(f) Tap “OK” (g) Confirmation screen (h) Internal memory clear

After correcting, tap “OK”. Tap “OK” When initialize ICX, you have to clear
ICX internal memory. Otherwise you
can’t view data in some cases.

(i) Memory clearing (j) Tap “OK”

NOTE
Shall not download immediately after
memory clear, because data is empty
(Dataviewer could not recognize empty
data as downloaded data. Operate
equipment at least an hour, and
download data.
9. Data Downloading – How to Start Dr.ZX -1/5
Turn key switch Confirm the Connect Dr.ZX to Turn key switch Switch on Palm.
“OFF”. engine-learning equipment. “ON”.
switch is OFF.

Start Dr.ZX. Select Select Select “Data Select “Data


“HMS_LargeMid” “Communication Download”. Download”.
. Start”.

Download Menu
9. Data Downloading – How to Start Dr.ZX -2/5
(a) Turn key switch “OFF” (b) Check Engine learning switch is OFF

Stamp

ZX110 & up, 120C & up

ZX70/80/75US/75UR & 80C


9. Data Downloading – How to Start Dr.ZX -3/5
(c) Connect Dr.ZX to equipment.

Connect
ZX110 & up, 120C & up

Connect

ZX70/80/75US/75UR & 80C


9. Data Downloading – How to Start Dr.ZX -4/5
(d) Turn key switch “ON” (e) Switch “ON” Palm (f) Start Dr.ZX

NOTE
Main switch is vary by Palm model. Tap “Dr.ZX” icon on Palm.
Shall not start engine.
Above shows Palm m500 / 505 / 515.

(g) Select “HMS_LargeMid” (h) Select “Communication Start” (i) Select “Set-ICX”.

Tap “ ” of “HMS_LargeMid”. Tap “ ” of “Communication Start”. Tap “ ” of “Data Download”


9. Data Downloading – How to Start Dr.ZX -5/5
(d) Download menu
10. Data Downloading – Download
Flow

Select “Data Select “Data Downloading. Quit


Download” Download” downloading.

Palm Operation

(a) Select “Data Download” (b) Downloading (c) Quit download

Tap “ ” of “Data Download”. Download will start automatically after Download will start automatically after
selecting data download. If you want selecting data download. If you want
to cancel download, tap “Cancel”. to cancel download, tap “Cancel”.
11. Data Downloading – Check Downloaded Data
Flow

Select “Save View data.


Data Check”.

Palm Operation

(a) Select “SaveDataCheck” (b) View data

Tap “ ” of “SaveDataCheck”. Download data have not uploaded to


PC will display. Tap “OK” to quit.
12. ICX Self Diagnoses – Flow
Turn key switch Confirm the Connect Dr.ZX to Turn key switch Switch on Palm.
“OFF”. engine-learning equipment. “ON”.
switch is OFF.

Start Dr.ZX. Select Select Select “Set-ICX”. Enter password.


“HMS_LargeMid” “Communication
. Start”.

Tap “Start”. Select “ICX If errors are


Diagnosis”. shown, tap
“Retry”.
13. ICX Self Diagnoses – Operation -1/5
(a) Turn key switch “OFF” (b) Check Engine learning switch is OFF

Stamp

ZX110 & up, 120C & up

ZX70/80/75US/75UR & 80C


13. ICX Self Diagnoses – Operation -2/5
(c) Connect Dr.ZX to equipment.

Connect
ZX110 & up, 120C & up

Connect

ZX70/80/75US/75UR & 80C


13. ICX Self Diagnoses – Operation -3/5
(d) Turn key switch “ON” (e) Switch “ON” Palm (f) Start Dr.ZX

NOTE
Main switch is vary by Palm model. Tap “Dr.ZX” icon on Palm.
Shall not start engine.
Above shows Palm m500 / 505 / 515.

(g) Select “HMS_LargeMid” (h) Select “Communication Start” (i) Select “Set-ICX”.

Tap “ ” of “HMS_LargeMid”. Tap “ ” of “Communication Start”. Tap “ ” of “Set-ICX”.


13. ICX Self Diagnoses – Operation -4/5
(f) Enter password. (g) Tap “OK”

TIP
You can use keyboard to enter
password. by tap “abc” or “123” on
GRAFFITI area.
Tap entering column, and enter After enter password, tap “OK”.
password. Default password is
zx2000.

(i) Tap “Start” (j) Select “ICX Diagnosis”

Tap “ ” of “ICX Initial Setting”. If “ICX


Initial Setting “ is not in menu, tap “ ”
or “ ” to changeover menus.
13. ICX Self Diagnoses – Operation -5/5
(f) No error(s) detected

If errors have not detected, above


message will display. Tap “ESC” to
quit.

(g) Error(s) detected (h) Still error has detected (h) Still error has detected

If any errors have detected, error If still errors have detected, error Content of error will display. Tap “ ”
code will display. Tap “Retry” for code will display. Tap “Detail” to check or “ ” to changeover error.
confirmation. content of each error. Tap ”ESC” to quit.
14. Change Password – Flow
Turn key switch Confirm the Connect Dr.ZX to Turn key switch Switch on Palm.
“OFF”. engine-learning equipment. “ON”.
switch is OFF.

Start Dr.ZX. Select Select Select “Set-ICX”. Enter password.


“HMS_LargeMid” “Communication
. Start”.

Tap “Password”. Change NOTE


password. New password will apply to
all Dr.ZX function.
15. Change Password – Operation -1/5
(a) Turn key switch “OFF” (b) Check Engine learning switch is OFF

Stamp

ZX110 & up, 120C & up

ZX70/80/75US/75UR & 80C


15. Change Password – Operation -2/5
(c) Connect Dr.ZX to equipment.

Connect
ZX110 & up, 120C & up

Connect

ZX70/80/75US/75UR & 80C


15. Change Password – Operation -3/5
(d) Turn key switch “ON” (e) Switch “ON” Palm (f) Start Dr.ZX

NOTE
Main switch is vary by Palm model. Tap “Dr.ZX” icon on Palm.
Shall not start engine.
Above shows Palm m500 / 505 / 515.

(g) Select “HMS_LargeMid” (h) Select “Communication Start” (i) Select “Set-ICX”.

Tap “ ” of “HMS_LargeMid”. Tap “ ” of “Communication Start”. Tap “ ” of “Set-ICX”.


15. Change Password – Operation -4/5
(f) Enter password. (g) Tap “OK”

TIP
You can use keyboard to enter
password. by tap “abc” or “123” on
GRAFFITI area.
Tap entering column, and enter After enter password, tap “OK”.
password. Default password is
zx2000.

(i) Tap “Password” (b) Enter current password

TIP
You can use keyboard to enter
password. Tap “abc” on GRAFFITI
are.

Enter current password. Default


password is zx2000.
15. Change Password – Operation -5/5
(c) Tap “Execute” (d) Enter new password (e) Tap “Execute”

(f) Re-enter new password (g) Tap “Execute” (h) Tap “ESC”

NOTE
New password will apply to all
Dr.ZX function.
MIC Mining
Super Large Excavators (EX1200-5 & up) Monitoring System
Operation Manual

Hitachi Construction Machinery Co. Ltd.


1. Necessary Tools & Cable Connection
2. Connector Location on Equipment for Monitoring
3. How to start MIC_Mining
4. Using CODE by Situation
CODE
5. Code “SAD-P”
6. Code “SAI-P”
7. Code “DDL-P”
8. Code “MEC-P”
9. Code “SEC-P”
10. Code “SEC-P”
1. Necessary Tools & Cable Connection
Necessary tools

(b) HotSync® Serial cable (c) Download cable

Dr.ZX must be installed. Hitachi Purchase from local market. Provide This is Hitachi unique part. Make an
recommends following models. cable that adapt to your Palm. order to your parts ordering channel.
SONY Hitachi part no. is 4486988.
CLIe PEG-TJ25
PalmOne Inc.
m125 / 130 / 500 / 505 / 515
Tungsten T2 / T3 / C

Palm

Serial cable

Download cable

Equipment
2. Connector Location on Equipment for Monitoring
(a) EX1200-5 (b) EX1200-5C (c) EX1900-5 & up
3. How to start MIC_Mining – 1/3

Turn key switch to off Connect cable to Check lamp on Check jumper
position. equipment. download cable is off. connector is not
connecting to cable.

Turn key switch to on Check lamp on Switch on a PDA. Start Dr.ZX


position. download cable is
blinking.

Start MIC_Mining.
3. How to start MIC_Mining – 2/3
(01) Turn key switch “OFF” (02) Connect cable to equipment (03)
(c)Check
Turn key
Jumper
switch
connector
“ON”

Connect cable to equipment. Make


sure that key switch is at of position.
Otherwise there is a possibility that
fuse will burn out.

Make sure that nothing is connected


to jumper connector on download
cable.

(c) Turn
(04) Turn key
key switch
switch “ON”
“ON” (05) Check lamp is blinking (06) Switch on PDA

Check lamp on cable is blinking at a Above shows PalmOne m500. Switch


certain interval. location is vary by model.
3. How to start MIC_Mining – 3/3
(07) Start Dr.ZX (08) Kind menu (09) Main screen

Tap “Dr.ZX” icon. Tap “ ” of “EPVC_Mini”.

(10) Quit MIC_Mining

Tap home icon.


4. Using CODE by Situation
When deliver equipment to customer. SAD-P Initialize DLU

When replace DLU. SAI-P Set equipment serial no.


recorded in DLU & initializing.

Download data from equipment. DDL-P

When data could not view on data viewer. MEC-P Clear DLU internal memory.

Troubleshooting SEC-P Check communication line


between sensor & controller.

CMC-P Check communication line


between controller & DLU.
5. Code “SAD-P” –1/9
When perform this code
Perform this code, when you deliver equipment to customer. Otherwise DLU would not record monitoring data properly, and also you or
your customer could not view monitoring data by viewer.

Flow of this code


Set time difference from Set local date & time. Set service meter Check equipment serial
GMT. reading. no. recorded in Data
logger.

Clear memory in data Check information Confirmation


logger. recorded in data logger.
5. Code “SAD-P” –2/9
(01) Set time difference (02) Date & Time adjustment (03) Date & Time adjustment

Tap “ ” to set time difference Tap menu icon. Tap “SettingAdjustment” in tools
between GMT. List of time difference menu.
is at Code “SAD-P” –9/9.

(04) Date & Time adjustment (05) Date & Time adjustment

TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.

Enter name of person who will set Tap “Next”.


date & time at name column, and
enter clock at work code column.
5. Code “SAD-P” –3/9
(06) Date & Time adjustment (07) Date & Time adjustment te (08) Date & Time adjustment

Date & time current recorded in DLU Tap “Date”. Tap “Today”. Date & year will set
will display. If you have to adjust, tap automatically. Before setting date,
“Change”, if no need to change, tap confirm date on Palm is same as
“Set”. local.

(09) Date & Time adjustment (10) Date & Time adjustment (11) Date & Time adjustment

Tap “Time”. Tap hour and adjust to local by Tap minute and adjust to local by
tapping “ ” “ ”. tapping “ ” “ ”.
5. Code “SAD-P” –4/9
(12) Date & Time adjustment (13) Date & Time adjustment (14) Date & Time adjustment

Tap minute and adjust to local by If date & time are same as local, tap Message will display. Tap “Ok” to set
tapping “ ” “ ”. “Set”. date & time. Tap “Back” to correct
date & time.

(15) Service meter adjustment (16) Service meter adjustment (17) Service meter adjustment

Main screen Tap menu icon. Tap “SettingAdjustment” in tools


menu.
5. Code “SAD-P” –5/9
(18) Service meter adjustment (19) Service meter adjustment

TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.

Enter name of person who will set Tap “Next”.


service meter at name column, and
enter run at work code column.

(20) Service meter adjustment (21) Service meter adjustment (22) Service meter adjustment

If service meter reading is not match Tap “ ” “ ”, and adjust service


to equipment, tap “Change”. meter reading to actual equipment.
5. Code “SAD-P” –6/9
(23) Service meter adjustment (24) Serial no. check (25) Serial no. check

Message will display. Tap “Ok” to set Main screen Tap menu icon.
service meter reading. Tap “Back” to
correct service meter reading.

(26) Serial no. check (27) Serial no. check

TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.

Tap “SettingAdjustment” in tools Enter name of person who will check


menu. serial no. at name column, and enter
serial-no at work code column.
5. Code “SAD-P” –7/9
(28) Serial no. check (29) Serial no. check. (30) Serial no. check

Tap “Next”. If serial no. does not match to Tap “Ok”.


equipment, carry out “SAI-p”. Tap
“Set”.

(31) Serial no. check (31) Serial no. check (32) Confirmation

Even serial no. is correct, please Tap “Ok”. Main screen


carry out memory clear, when deliver
new equipment to customer.
Otherwise data will corrupt.
5. Code “SAD-P” –8/9
(33) Confirmation (34) Confirmation (35) Confirmation

Tap menu icon. Tap “SystemCheck” in tools menu. Confirm every information on this
screen are correct. If not, please
re-adjust. If serial no. doesn’t match,
perform SAI-P.
5. Code “SAD-P” –9/9
6. Code “SAI-P” –1/9
When perform this code
Perform this code, when you replaced DLU. Otherwise you can’t view monitoring data on data viewer.

Flow of this code


Set equipment serial Clear memory in data Set time difference from Set local date & time.
no. logger. GMT.

Set service meter Check equipment serial Clear memory in data


reading. no. recorded in Data logger.
logger.
6. Code “SAI-P” –2/9
(01) Serial no. correcting (02) Serial no. correcting (03) Serial no. correcting

Main screen Tap menu icon. Tap “SettingAdjustment” in tools


menu.

(04) Serial no. correcting (05) Serial no. correcting

TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.

Enter name of person who will set Tap “Next”.


serial no. at name column, and enter
serial-no at work code column.
6. Code “SAI-P” –3/9
(06) Che Serial no. correcting (07) Serial no. correcting.

TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.

Serial no. currently recorded in DLU Tap serial no. column, and enter
will display. Tap “Change”. correct serial no.

(08) Serial no. correcting (09) Serial no. correcting (10) Serial no. correcting

After entering correct serial no., tap If serial no. you entered is correct, tap Tap “Yes” to clear DLU internal
“Set”. “Ok”. If you want to re-enter serial no., memory. Otherwise data will corrupt.
tap “Back”.
6. Code “SAI-P” –4/9
(11) Serial no. correcting (12) Set time difference (13) Date & Time adjustment

Tap “Ok”. Tap “ ” to set time difference Tap menu icon.


between GMT. List of time difference
is at Code “SAI-P” –9/9.

(14) Date & Time adjustment (15) Date & Time adjustment

TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.

Tap “SettingAdjustment” in tools Enter name of person who will set


menu. data & time at name column, and
enter clock at work code column.
6. Code “SAI-P” –5/9
(16) Date & Time adjustment (17) Date & Time adjustment (18) Date & Time adjustment te

Tap “Next”. Date & time current recorded in DLU Tap “Date”.
will display. If you have to adjust, tap
“Change”, if no need to change, tap
“Set”.

(19) Date & Time adjustment (20) Date & Time adjustment (21) Date & Time adjustment

Tap “Today”. Date & year will set Tap “Time”. Tap hour and adjust to local by
automatically. Before setting date, tapping “ ” “ ”.
confirm date on Palm is same as
local.
6. Code “SAI-P” –6/9
(22) Date & Time adjustment (23) Date & Time adjustment (24) Date & Time adjustment

Tap minute and adjust to local by Tap minute and adjust to local by If date & time are same as local, tap
tapping “ ” “ ”. tapping “ ” “ ”. “Set”.

(25) Date & Time adjustment (26) Service meter adjustment (27) Service meter adjustment

Message will display. Tap “Ok” to set Main screen Tap menu icon.
date & time. Tap “Back” to correct
date & time.
6. Code “SAI-P” –7/9
(28) Service meter adjustment (29) Service meter adjustment

TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.

Tap “SettingAdjustment” in tools Enter name of person who will set


menu. service meter at name column, and
enter run at work code column.

(30) Service meter adjustment (31) Service meter adjustment (32) Service meter adjustment

Tap “Next”. If service meter reading is not match Tap “ ” “ ”, and adjust service
to equipment, tap “Change”. meter reading to actual equipment.
6. Code “SAI-P” –8/9
(33) Service meter adjustment (34) Service meter adjustment (35) Confirmation

Message will display. Tap “Ok” to set Main screen


service meter reading. Tap “Back” to
correct service meter reading.

(36) Confirmation (37) Confirmation (38) Confirmation

Tap menu icon. Tap “SystemCheck” in tools menu. Confirm every information on this
screen are correct. If not, please
re-adjust.
6. Code “SAI-P” –9/9
7. Code “DDL-P” –1/5
When perform this code
Perform this code, when you attempt to download monitoring data from equipment

Flow of this code


Enter name of person Set time difference from Start download. End message will
who will attempt to GMT. display
donwload.

NOTE
Downloaded data will belong to
customer. Shall not disclose data to
third parties, or to even internal
personnel, if they aren’t authorized.
7. Code “DDL-P” –2/5
(01) Enter name (02) Set time difference

TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.

Tap name column, and enter name Tap “ ” to set time difference
who attempt to download. If you between GMT. List of time difference
already registered, tap “ ” to find is at Code “DDLP” –3/5.
your name.

(03) Download (04) Download (05) Download

Tap “Next”. Information will display. Tap “OK” to


quit.
7. Code “DDL-P” –3/5
7. Code “DDL-P” –4/5
Caution
Caution - 01 Caution - 02 Caution - 03

Do not terminate palm application Do not change key switch to any Do not disconnect cables while
while downloading. Otherwise data position while downloading. downloading. Otherwise data will
will corrupt. Otherwise data will corrupt. corrupt.
7. Code “DDL-P” –5/5
Errors
If any error occurred, please take following procedure, and retry download.
Turn key switch to off Disconnect download Quit tools running on Connect cable to
position. cables. Palm. equipment.

Check lamp on Check jumper Turn key switch to on Check lamp on


download cable is off. connector is not position. download cable is
connecting to cable. blinking.

Switch on a PDA. Retry code DDL-P.


8. Code “MEC-P” –1/3
When perform this code
Perform this code, when you can’t view data on data viewer, other information (such as equipment serial no., data & time, engine running
hour) that recorded in DLU are correct.

Flow of this code


Select Enter name & work Clear memory.
“SettingAdjustment” in code “serial-no”.
menu.
8. Code “MEC-P” –2/3
(01) Memory clear (02) Memory clear (03) Memory clear

Main screen Tap menu icon. Tap “SettingAdjustment” in tools


menu.

(04) Memory clear (05) Memory clear

TIP
You can use keyboard to enter
password. Tap “abc” or “123” on
GRAFFITI area.

Enter name of person who will clear Tap “Next”.


internal memory at name column, and
enter serial-no at work code column.
8. Code “MEC-P” –3/3
(06) Memory clear (07) Memory clear (08) Memory clear

Tap “Set”. Tap “Ok”. Tap “Yes”

(09) Memory clear

Tap “Ok”.
9. Code “SEC-P” –1/4
When perform this code
Perform this code, when you want to check communication line between sensor to controller.

Flow of this code


Select “SystemCheck” Select “Conditions” is Select “Sensor Faults”
in tools menu. System check menu. in .system check menu.
9. Code “SEC-P” –2/4
(01) Sensor communication check (02) Sensor communication check (03) Sensor communication check

Main screen Tap menu icon. Tap “SystemCheck” in tools menu.

(04) Sensor communication check (05) Sensor communication check (06) Sensor communication check

System check main screen. Tap menu icon. Select “Condition” in system check
menu.
9. Code “SEC-P” –3/4
(07) Sensor communication check (08) Sensor communication check (09) Sensor communication check

Equipment conditions will display/ Tap menu icon. Select “Sensor Fault” in system check
Check figure(s) will change while menu.
operating. Information will vary by
equipment models.

(10) Sensor communication check

If there is a “NG” on sensor, there will


be communication fault in sensor
and/or sensor line. Tap “ ” or “ ” to
changeover sensor.
9. Code “SEC-P” –4/4
Sensors equip on each models
EX1200-5/5C EX1900-5 EX2500-5 EX3600-5 EX5500-5

Hydraulic. Oil Temperature Sensor O O O O O

Fuel Temperature Sensor NA NA O NA O

Operation Pressure Sensor O O O NA O

Travel Pressure Sensor O O O O O

[R] Engine Speed Sensor O O O O O

[L] Engine Speed Sensor NA NA NA NA O

Intake Air Temperature Sensor 1 NA NA NA O NA

Intake Air Temperature Sensor 2 NA NA NA O NA

Front Swing Temperature Sensor NA NA NA O NA

Governor Angle Sensor O O NA O NA

Coolant Temperature Sensor NA NA NA O NA

Fast-fill Pressure Sensor NA NA O O O

Exhaust Temperature Sensor 1 O O NA O NA

Exhaust Temperature Sensor 2 NA O NA O NA

O = Equip on equipment
NA = Not available on equipment
10. Code “CEC-P” –1/3
When perform this code
Perform this code, when you want to check communication line between controller and DLU..

Flow of this code


Select “SystemCheck” Select “Conditions” is
in tools menu. System check menu.
10. Code “CEC-P” –2/3
(01) Communication condition (02) Communication condition (03) Communication condition

Main screen Tap menu icon. Tap “SystemCheck” in tools menu.

(04) Communication condition (05) Communication condition (06) Communication condition

System check main screen. Tap menu icon. Select “Condition” in system check
menu.
10. Code “SEC-P” –3/3
(07) Communication condition

Communication condition will display.


If communication condition is not
“OK”, please check line between
controller and DLU.