You are on page 1of 78
'ceuiidoRANA Enger San Bh uch on 25.4471 Sng er, cya sd mains A Bea) iEC 60078-17 INTERNATIONAL STANDARD NORME INTERNATIONALE Explosive atmospheres — Part 17: Electrical installations inspection and maintenance ‘Atmosphéres explosives — Partie 17: Inspection et entretien des installations electriques ‘ean RA Eagan SB Pua en 26.9012 Singer eam ty ig aig pad SN Ba) A Conyetto maT, err, etre | spear rece me eee es nee (Alan crac om ere bt our net EC mai Nasa Commies reer mimaaae card Yo do El ue Goma nina rb C6 pu Oona Some ate na Cm» oe ont Sr moet te Ena aia ‘About the EC ‘he mail Choral Capmson (EC) We ig ght pation at papa a ies ‘About IEC publications Sect SENS ne eet rng Gxogun eo ou nach By say of ta (rece nba, te ate comma.) vs oats on rer nanan so pe piso Seppe sist Bm ma an on ae (Eoin noche en sana ngage fae tan ee etd ccs Cnt a chatty SINR Sate os ht bin os ter ssa, eae wt ne Cine See ‘Apropos dela CEI (Giecteuser Linear eran at emt agansain manda ue "Somer transept cog ates eos, snug sauces Sree ‘Apropos des publications CE! sc pg ena Lewd RNA Engng Sn Bh Paced 26462012 Sg ew ene cp ed wong rig IAM Bed Use dion 4.0 2007-08 INTERNATIONAL STANDARD NORME N Explosive atmospheres ~ Part 17: Electrical installations inspection and maintenance “Atmospheres explosives — Partie 17: Inspection et entretion des installations tlectriques Lead RANA Ej Sn fe Puchasedon 2-Ne 212 Sge trate ny, coping an eign (SRA Be) CONTENTS FOREWORD. INTRODUCTION. + Score. 2 Normative rterances 3 Texms and detintons 4 Documentation 42 Qualeation of personne! 4.3 Inspections. 43.1 Genera 422 Grades of inepection 43.3. Types of inspection 44 Peviedcinspecions 441 Personnel 443 Moveable equipment 45. Continuous supervision by skied personnel 451 Concept 452. Objectives 453 Responsbities 4.5. Frequoney af inspection 455 Documents 456 Tranng 48 Maintenance requrements 46.1 Remedial measures and aterations to eauipment 482 Waintenance of fone cables 446.3 Wndrawal fom serves 46. Fastenings and oo's 4.0.1 nstaliations ahr then intonsical eafecivcuits 48.2 Intensically safe insialaons 4.9. Earn and equipotent tending 4.10: Spocie condone of use 4.41 Movable equipment and ite connections 4412 Inepecton sehedues (Tables 110.4) 4421 Egmont appropiate othe EPLizne ogra ihe 4122 Equipment group is care, 4423 Equipment maximum surtace temperate is corect, 4124 Eauipmont exeutidanttieaion 4425 Cable gland 14126 Type of cable is appromriae 412.7 Sealing. 4:12. Faulto9p impedance or earthing resistance 0079-17 © 1¢:2007 10 40 42 12 13 13 13 13 4 4 15 18 18 15 18 18 18 18 8 18 48 19 cae 2 49.012 Sage a ly gd mttig pd SB) 0079-17 © 1€¢:2007 4.1209 Insulation resistance 412,10 Overioad protection 5. Adational inspection schedule requirements 5:1 Type of protection "s*~ Flameprot enclosure (se Table 1 and VEC 60079-1) 5.11 Flameproot joins (ee IEC 6079-1) 52 Type of protocton“e*~ nereated safety (ee Tablet and 1€C 600787), 521 Ovenoads 53. Type of protection “and 0 tnsc safety (see Table 2 and IEC 60079. 11 oriec or24t%) 534 General 5.32 Documentation 53.3. Labeling 534 Unauthorzed modifications 53.5 Associates apparatus (sally interface) between htnsicaly sof and non-invinteally safe cuts 536. Cables 537 Cable screens 53.8 Pointiopoiat connections 153.8 Earth continuity of non-galvanicay ote cuts {5.40 Eartn connections to maintain the integrity ofthe intrinsic safety 153.11 tntrnscaly Ste ckeut earthing andlor nslation {53.12 Separation between inuinscaly safe and non-tinsically safe 54 Typo fpretocton“p* and “pO ~ Pressurized encesue eee Table 3 end lec e0ore2 alec 612414) 5:5. Type ofprotecton “(560 Table 1 or 2 ang IEC 6078.15), 851 General 552. Restrted breathing enclosures 56 Type ol protection YD" Pretection by enclosure (ee Table 4 and weet : 58.7 Types of protection “mand "m0" "etpomdor ting), 8 Inspoction schedules (encapsuation,'o" oikimmersion) ane Annee (eam) Typles inipaction pe ‘Annex 8 (normative) Knowledge, skils and competences of responsible persons “echnical persone wih execute function and operatives” Annex C (informative) Inroducion of an atanatve risk assessment method ‘encompassing “equipment protection levels for Ex equipment Bibliography. 4 Table 1 inpection schedule for Ex ‘lose, V= Visual) Xe" and Ex isalaions (0 Table 2~ Inspection schedule for Ex, ND" and" instalietions “Table 3- Inspection schedule for Ex “a and “pD"instalations Table 4 ~ Inspection schedule for Ex 10" instalation. Table C4 ~Tradtonal relationship of EPLS to zones (no adctional risk assessment) Table ©2 ~ Description of rsk of ignition protection proved 2 22 22 22 2 2 2 6007-17 © 10-2007 INTERNATIONAL ELECTROTECHNICAL COMMISSION EXPLOSIVE ATMOSPHERES ~ Part 17: Electrical installations inspection and maintenance FOREWORD Se acetal Sra fr 3 lrderdeaon 80) m accordance nik cndors erines by 1 Ind te pow [dledan ay IEC ablanion aod he cfespnargnaconl a Tcana abies hal Se cer maces i | 4 2 { 7 ii i 9) Aner » ann he psa a ee fh lamas oh I Publ may De he sto oy a ash pate Intemational Standara {EC 60079417 ns bh hazardows areas and instalation rea foroxplosve atmospreres boon preparad by subcommittee 31: Classification ments, of IEC techrical commen 3¥: Equipment ‘This fourth eaton cancel and ceplaces the thd ection pubished in 2002 and constitutes @ {echniea revo ‘The significant technical enanges wit respec tothe previous eon a a ftlows: + Aattional requirements for inspection and maintenance of lactic instaiaions for ‘Combustibie dusts ae ince + Knowledge, shils and competencies of “esponsibis persons", “echnical persons with recut funelion” and “operatives” ae expained in ve Anne B + Equipment Protection Levels (EPL) have been inrotuced an ate explained in the new anon e Lead RNA Enpreing Sh Bh Puce en 2649-2072 eo cr ond twa PB SAN Bes) 60079.17 © 160-2007 ‘The text of his standard is based on the following documents: ul information onthe voting forthe approval ofthis stander can be foun inthe report on ‘ling indicted inthe above table ‘This publication has been erated in accordance with he ISQIEC Directives, Part 2 ‘ist ofa pants ofthe 1EC 60079 seces, under the general i be found onthe TEC wetste Explosive atmospheres, can ‘The commites has decited thatthe contans of the pubistion wil remain unchanged unt the maintonance result date inicatod onthe {EC web sie under "ntpiiwebsioe ieee In the cata elated tothe specie publeaton. At ths date, the publication wil be + eeconfimes, + itnrawn, + replaced by a revised eaiton, or + amended Leet aN Eee Sin el Pachsnon 6A Sa aa ny pig eneotng oe SIM Baas) 80078-17 © 1¢:2007 INTRODUCTION Electrical instaliatons in hazardous areas pos Suitable for operations in such atmospheres. I ls arsenal for reasons of safely In thos fafeas that oughout the Ie of such istaations, the htegry of those special teatures preserved they therelore require inal inspection and sitter features specaly designed to rnd thom 2) regular periodic inspections thereafter, of ) continuous supervision by skied personne Lene RAEI Son | Rha 2046012 See rn ny nya ad eg prog SRM Be 60079-17 © 1€C:2007 EXPLOSIVE ATMOSPHERES ~ Part 17: Electrical installations inspection and maintenance 1 Scope This pat of IEC 60079 apples to users and covers factors det related tothe inspection and maintenance ofelecial mstaauons witin hazardous areas only. where the hacerd ay [Be caused ty lammabie gas, vapours, mista, eta, Hbres.or things rot incade + athe tundamentainstaaton and inspection requeemens fo electrical instalation ‘+e verification of ectcal equipment + the repair and reclamation cf explosion protected equipmant (see IEC 60078-19). ‘This standard supplements the requirements of IEC 603646. In the caso of dusts, fas o¢tvngs_ the level of housekeesing may influence the inspection and mantenance requirements. This standard is intended to be appiod where tere can te a risk due tothe presence of iplosive gas or dus matures wit nr or combutibie dust nyero under normal amospheie ondtons,h dose not apy to 1+ underground mining areas ‘+ ateas wnere a isk can arise ve tome pesence of hyord mitre, ‘dusts of explosives that 60 not requir atmospheric oxygen for combustion, + pyrophore substances 2. Normative references ‘The folowing coerenced documents are ingispensabie for he application of tis documont Foe dated ratnnnea ny thn attinn sas apige Far undsad tetoronsc, the ken ease ofthe referenced document (eluding any atendments)sppies TEC 60079.0, Explosive atmospheres - Part 0: Equipment - Gener requirements IEC 60079-1, Explosive atmospheres ~ Pert 1: Equipment pretaction by Rameproot enclosures i {EC 60078.2, Explosive atmospheres - Part 2: Eavinmentpatecton by prossuized fenctosures >" EC 60078-7, Explosive atmosoneres- Part 7: Equipment protection by increased sofety EC 80079-10, Electrical apparatus for explosive gas slmossheres - Part 10: Classification of EC €0078-11, Explosive atmospheres ~ Par 15: Equipment 2vtesion by intinsie safely lena NA grec Sin Pca n.d rin pt SA Ba 60078-17 9 16-2007 EC 60070-14, Electrica! apparatus for explosive ges atmospheres Part 14: Electrical Instalatone n hazardous areas (other than mina) EC €0078-15, Electrical appartus for oxposivo gas atmospheres — Part 15: Construction, {est and marking of type of protection" electal wpa EC 60078-19, Explosive atmospheres — Part 19:Equpmen repair, overhaul and rectamation IEC 60364-5, Low votoge electric! installations - Port 6: Veiication VEC 61241 (al parts), Conbustse sist NEG 6126%-1, Etectneal apparatus for use In the pretence of combustible aust — Part "rPretgcton by enclosures 0" IEG 61241-4, Electrical appara for use Inthe presence of combustible dust ~ Part 4 Type Of protection “pD" EC 61241-10, Electncal apparatus for use in the presence of combustible dust ~ Part 10; Cisssiteation of aroas whare combustible Gusts ae or may bo presort EC 6124-11, Electrical apparatus for use inthe prasence of combustible dust ~ Part 11 Protectan by intense safety 9D" EC 61241-14200, Electrical apparatus for use in the presence of combuetble dust — Part 18: Selecton an instalation 3 Terms and definitions For he purposes ofthis document, he tam and defintions given in HEC 6007040 and the Talowing apo. Inspection nhisn encompasses those aspects cover bya visual inspection and, in aaiton, "dontfie thane daft, such se loose bots, which wil ts apparent only by the ase of acc ‘auipment fr example steps, (where necessary), and tons a2 ‘continuous supervision Frequont atendance,inapacton, service, care and maintenance ofthe electicainstatation by Stiled personnal who have expernce in the apecttc nsaleton ands envcorment in ore {o'mantain tn explosion protection fsturs of the nstalation m sttactory sondton 33 Setated inspection inspection which encompasses those aspects covered by a close inspecton and, in aditon ‘dentfiee tose detec, euch as oose terminations, whch wil eny be apparent by opening the enclosure, andr using, were necessary, tools and bst equipment Leno RUA gn SB. Pea A202 Se ren ry cna and moi pi AN Ber) 60078.17 6 16c:2007 a4 iarardous area ‘uanties such as Torque special pe ‘auipment| ent, or may be expected to be prosen, In ons forthe costtction, ntaiaton and ues of as Init inspection tons before they are brought inte stilon compcsing careful scrutiny ofan tem cared out ether without dismanting, o wth the iiton of paral siemanting os Teqived, supplemented by means ach ae messorort. Oder to arrive ata rotate conclusion aslo tho condition of an am {Combination of any action cased out to retain an item in, 0: estore itt, cenitions in which IU able to meet the requirements of the rlevant specication and perorm Is fered funetions 8a in which an explosive atmosphere is not expected to be present in quantities such a to ure special precautions fr the constuction, instalation ang use of equipment Mspecton ofa electrical equipment, systems and installations carted out on a routine basis 310 imple inspection Inepecton oa proportion of the elscticsl equipment, sysems and insaletions an ‘hited person One wnOae Tainng has melUded INstUcON on the various ‘ype of protection and Instaation practices, the raguremenis of ths "standerd the. relevent rail aulaonsicompany rules plead to the instalaton and.on the genera pencils ot sree ‘aseieaton aaa {cchnieal person with exeeutive function person grovding Technical management of the skied personel, having adequate knowledge In the feid of explasian protection, having famianty wih the local conditions, navies {amity with he instalation and who has ovralrespanaty and conrl a the nepecton systems forthe olocicalequpmen within hacardovs ares 313 Visual inspection Inspection which iris, without the use of access equipment o fools, those defects, such ‘2 missing bolts, which wil be apparent fo te eye seo ANA ing SB Paco 2643-2012 Singer kaa ly copia meting poi SRM aha) =10- 60078-17 © 1€¢:2007 4 Goneral requirements 44 Documentation For the purposes of inspection and maintenance, upto ‘tems shalbe avaible documentation ofthe folowing 4) zone classification of areas and, it incudes, the equipment protacton level (EPL) requved foreach location (ane IEG 6B078-10 and 1EC O12e1° 0), ) for gases: equipment group (IA, 18 oI) and temperature class raguicements, ©) for dusts: equipment group (IIA, HIB. ex WiC) vd ms equrement 2) equipment charactoristcs 0g. tomperature 1 ©) records suliclent to enable the explosion protected equipment to be maintained in ‘ecordance wih is type of protection (see IEC 60079-14andiEe 61241-14), (ar list and location of euipment spares, certitetes, tecvncal information), ings, ype of protection |? rating, crrason 1) copie of previous ingpacton records, Requirements fr other éocumentation that may be necessary ste provide in JEC B007S-14, TEC 80079. 19 anciee e124 ts 42 Quatincaton of personnel The inspection and maintenance of installations shal bo carried out only by experianced personnel. whose talring nas included insvucton en the varios types Of protection ane Irstaaten “pracices, ina roquements ofthe’ standard, the. relevant nations Fegulationsicompany rules eppicele lathe inition and on the general princes of ‘lasetieaton (coo Annex 8}. Appropriate continuing eduction or raining shall ba underta By beso! ener basi, Enidece ofthe relevant experiance ane ang lames 43° Inspections 431 General To ensure tha the installations a ‘maintained in satisfactory condition for continued use 1) raquar perdi inspections. or ©) contnacutsupersision by skied! personne ‘an, whore necossary, maintenance Be cated out Following any adjustment, maintenance, rapa, rclamtin, modification or replacement the ‘equipment or relevant pate of equlpmom concerned shal be inspected in secoreance ith {ho relevant tems ofthe detailed column of Tables 1.2, 2nd 4 Were the codiiation pate oF markings on explosion protected equipment is misting ar Hogi, sitemative methods may be used to determine Faceetity tone catfeaion deta fof ihe specie equipment. The method used could incuds: adational isentfeaion labels wien incorporate ungue (ag) numbers, sonal numbes ar reference fo IMs insaliavon Leases RMA npr Sen Bh Pact 254912012 Sg eo, ci a main pried SF Bea 0079.17 © 1e¢:2007 one stabases. The method ofstlaching o king the labeling sal not reduce the integrity of the eulpment ‘The inventory and identification tagging method used for managing explosion protected euigment shall ve capable of tracking the replacement! cqugment with replacernent ot Feparec equipment, which may have diferent certestonmasange and dete tothe ori ulpment Wat any time there is a chango in tho area classification o° the Equipment Protection Level Fequrements ori ary eauipment is moved fom one locaton to ansiner a crock shall be Made te ensure that the type of protacon and surface temperature, where appropriste, are Sule for ta revises condone 1 plant or equipment is dismantled curing the course ofan inspection, precautions shal be laken during reassembly to ensure that he Intgey of he ype of pretation isnot impel, ‘which includes removing any residual dust end repiacing gasteta correc 43.2 Grades of inspection ‘The grade of Inspection may be Wsua, close oF detailed. Tablas 1, 2. 3 and 4, or mode’ {ables in accordance with 5:7, 23 approptate, detail the specie checks requed for these Itvoe grades of inspection Visual and close inspections can be pertoemed with the equipment energized, Detaled Inspectans wil generally require tha equipment to-be soa ‘The grade of inspection solcted for equipment using mara than ene type of protection (e.g Ex "ed. equipment) shall bo a combhaton of the relovnt cole from the Tables Bonen A 43.3 Types of inspection Inspections are used to check thatthe selected typ af pratacton and its instalation ppropriale. They are tobe deal iapections In accordance wih Tales 12.3 and ‘ormediied tables im accordance wi 5. a5 aporoo ») Peradi inspections may be visual or close In accordance with Tables 1, 2, 3 and 4, of rmoated tales n accordance with, a appropiate ‘Avrsual or close perocie inspection may esto the need ora further detailed inspection Sample inspections may be visual, lose of detalles. “he size and compostion of al samples sha be determined wi regs to he purpose othe wspection Continuous supervision utizing the visual or else inapestons of Tables 1 2, 9 ond 4, or Imogte tables in accordance with 8.7.38 appropiate, shal be accordance wih 45 Were ation fails outside ths capably for continuous supervision t shal be ubject to pena inapection Leese RUN En Sn he Puchong te ny, cig nea eed SIM Be) a2 0079.17 © 16-2007 “Tho results of al inal, perodc and sample inapoction shall be recorded and rained. The recording requirements for continuous supervision by sklld personnel are deta in 8.5.5. 44 Periodic inspections 444 Personnel Regular petioaie inspection requires personnel whe: 8) have @ krowlodge of area classiicaonlEPL and sulfeent technical Knowledge to Understane ts implications fr te locaton under conadeaton ) have tchnica! knowledge and understanding of for elocticalequpment ane installations usean ¢}_understans the requremens af visual, close and detec inepectons as they oat Inatates equpmen ang instalatons. practical equiements tothe Such personne wll need to be suficiemy independent ofthe demands ofthe maintenance ‘slvites, Tor example s0 8 Molt peludice heir abit to realy report te fining ofthe inspecten 442° Fixed installations To predict accustely an appropiate periodic inspection interval a complex issue. The fade o! inspection andthe interval results of previous ino testaliened fox sunlar equine Getermiing the iapecton strategy lants‘and envonmens, tis experience shal be used in Te oeet between pad wapactons hall aera! hee years wou seeking roar Lunce: an interval nas veen txe0, the instalation shal be subjected to adstonal interm Sample inspections to suppor or modiy the proposed interval. Silay, the grade, ot inspection wines to be determined. and here apain samgie inepacton an be Used {0 Support or moa the proposed inspection grade. Ongoiny reve ofthe resus of inepectons wi be aquiea To justly te interval between, and grase |, mepecons, ‘typical inspection procedure is shown diagrammatically in Annex A Movable elzcrical equipment (nana-nele, portable, and vanspeabe) is particulary prone to » (mersion dane Thal) et wae (remplasage puveruten) 5 Programmes dinspection son eine (vi Ie ‘Annexe A (informative) Procedure type inspection pour lesinspactons périodques Annexe 8 (romative) Convaissances, competences et avaliications des « personnes Fesponsables», «personnes avec quaifeatons techniques ayant une fonction ‘rmexe C (informative) Inteducton & une méthode atanalve <évalvation des FRequee inclvat los» iveaux de preston du mative» pon les materiels Ex Biolographe. Tableau 1 - Plan dinspecton pour ie installations Ex ede, Ex wer ot Ex sow (D = dbtaee, C= ve pres eV = vtuel) ‘Tableau 2 ~ Plan dinspecton pou es instalaions Ex vn, «D) Tableau 3 ~ Plan dinspecton pou ie installations Ex «pe et «pe sr 57 sr 56 50 58 38 50 50 38 39 60 0 0 6 ot ot 66 er o 2 8 east ani Engening eh Bh Pusan 2-AAd01/ Serkan, iy wetting pes IM aa) -40- 0079-17 © ce12007 Tebleau 4 ~ Pian singpection pour les insalaons Ex tC» es Tableau C.1— Relation wadtonnele ene EPLs et zones (sans evaluation de rsque complemen n Tebieau C.2 ~ Description de Is prtoction contre le aque SManNeb out nT ean NA Erni SB Pach n 66 22 Sig cy cn sn ang ibe RM Bea 60078-17 © CEL2007 oat COMMISSION ELECTROTECHNIQUE INTERNATIONALE ATMOSPHERES EXPLOSIVES ~ Partie 17: Inspection et entretion des installations électriques AVANT-PROPOS ta Ge eater chatemen! avec Orpennsionhirrabonale So Narmaizan (60), ‘spovsbn vt secord mienatonal sur is sje dts, lant Sones ue es Coates nasonayt Ge ET ‘atones cu regionals corespondaries Gover tre Manwees os lamas cary dons obs demares 5) el tena eo a sen yet. One cares etn npr ‘nose enpoyer auras ce ‘eteanes es engarept ws optcton Caves pecans psaton, nar Se Pete aro scus come 51: Classification de ges ‘instalation, du comae. eudes 31 eta" GEL oploeives Les modifications importantes par rapport &redion antérieue sant iniquées ci-dessous: *+ es exigonces suppementaes pout linspecton et Ferireen éinstalations elctiques + Les connaissances, qualifeations et compélences des « personnes rasponsabies » ‘personnes avec qualifications. techniques ayant une fonction de ‘catia et « perateurs = sontexpiquées dane la nauveie Annexe & ‘+ Des « riven deprotection dos équipements» ont intrduits at sont exsigués dans Ia nouvelle Arnone © isnt REN Engen Sen nace 2-46 202g en a, cyeg an stain pd A Beh aa 0078-17 © cEL:2007 Le toro de cote nore est bast sures documents suivants © rapport Ge vole nsiqué dant le tableay ci-dessus donre toute information sure vate ayant ‘Sou dT appeabaton de cate norm Cotte pubiaton a et reaigee solo tes Oecves ISO/IEC, Parte 2 Une lite do toutes ls partes ge a CEI 60079, sous le ite général Amosphéres explosives ost disponible suria site web de ta Cel, Le comite a décise que fe contenu de cette publication ns sera pas modifié avant a date de Iaintonance inaguse eur fo she web de la Cel so “hipifwebstowiec ch” dane es fonnboe relate & la publication recherche. A celle ote, la pubiaton sere + templacée par une edition reviebe, ou + amends, Leen o RUNA pin Si. ated on 3-2) eee ny cry ad enon pe RM Ba 0070-17 © ceL2007 aa INTRODUCTION Les instalations slat aractoristques spect aractenstiques soit ans. les emplacements dangerour _possédent ongues pour le foncionnement dane de telies atmosphere ie secure dane coe emplacements, que fntogrlo de ce e tiles istiaions c'est pourguoe 8) soit des inspections périodgues requis, ») aot un urvellance continue par un personne! quai conformément a présente norme a, de Ventretien si nécessaire. Lito RON Energi ie Pech Sy 2012S ae hy, cpg ae eng oad (SRN aa re 6007-17 © cen2007 ATMOSPHERES EXPLOSIVES — Partie 47: Inspection et entrotion des installations électriques 1. Domaine a'application bg, eésona parte de le CEL 60072 sapplaye au wastur ot covire ls focus Secioment lee 8 Tinepection et @ ent les irstalauons éleciques sivees 8 Tinteeur dea emplacements Sengereur, ou la naque pet vent dos Qau de vapour, oe broultars, des poussires, dos floras ou des partcules & suspension inlammables. te ne comprand pas 1+ les autos exigences fondamentalas relatives & "intl Iratalatons lecinques + la virteation de réquipement lectus: + les partons et remises en état de matériel proligs conte les explosions. (voir fa Cer coore-e) jon et 8 inspection pour ts Cote nome constiue un complément pour es exigencesde ia CEI 602646. Dans Ie cas de poussives, fibres ou particles en sespension, le niveay de Fentreten ‘courant pout luancer les exigences Senreten et dinspeton Coats norme ost costings ate appiqude loraquil existe un regue a0 & la présence de gaz ‘rploste ou de. melanges de foussires dans Tat’ cu des, covehos” de. poussiotss ‘combustibles dans des condtionsatmosphesques narmales. Ele ne © appiave pat + aur emplacomonts obi enste un danger da & Ia présence de mélanges hybrids, “+ aux pousstres sexpios qui nexignt pas eoxygene de ak pour leur combustion, aux substances pyrophorques. 2 Références normatives les documents rdféroncts suivanis sont iniepensables pour 'epplicalion 6x ce document, Pou es relérences datdes, seule edition cto applique. Pour les relererces non dateo Te denice ection du document relerence ncn tout anendement)sappique (CEI 60075-0, aumospneres explosives - Parte 0: Matenel- Exigonces générales (CEI 50078-1, aumospheres explosives - Paro 1: Protection du matériel par envelogpes ‘nidonagrates ned CEI 60078-2, Aimospheres exploswes - Partie 2: rolecton eu motériet par enveloppe & Surpression interne > (CEI 60079-7, Atmospheres explosives - Paro 7: Protection de Féquipement par sécurité ‘Sugmemee <

You might also like