You are on page 1of 19
CONTENTS Introduction Lightning, a common phenomenon happens in Malaysia, especially during the monsoon periods. But how much do we know about lightning? 01 The destruction causes from lightning Installations where lightning protection is highly recommended to the following areas 02 Structural Lightning Design Consideration As Accordance To BS 6651:1990 The principal components of a lightning protection system Malaysia 03. Lightning & Earthing Protection ~ A Rainforest Country Rich Of ‘System Installation Drawing ‘Thunderstorm Products Introduction 04 A. Air Terminal Fixings 11 F.Earthing Accessories ~ Al, Taper Pointed Air Rod =F 1. Copper Rod ~A2 Multiple Taper Pointed Alr Rod -F2. Coupling =A3. Air Terminal Base =F3, Driving Stud ~A4, Ridge Saddle -F4, Earth Rod To Tape Clamp (Type A) 12. -F5. GUY Type Rod To Cable Clamp 05. B. Roofing Conductor Fixings -F8. Earth Bonding Points = B1. HDG Roofing Mount Support Hook -F7.E Type U Bolt Rod Clamp (N— Hook} -F8. Earth Boss - 82. HDG Roofing Mount Support Hook 43. ~ F9. Earth Bars (A= Hook) ~F10. Concrete Earth Chamber 06 - 83, Slate Holdfasts Support Hook =F. Earth Bar = BA, Slate Holdfasts Support Hook With L- Shape 14 G. Conductors = BS. Compound Type Rooting Support = G1. Bare Copper Tape 07 Accessories = G2. Bare Aluminum Tape = B6. Teflon Block - G3. Bare Galvanized Stool Wire - BT. Expandable Support Hook G4. Flexible Bare Coppor Braid = BB. Bolt & Nut 15. H. Supporting Accessories 08 C. Conductor Fixings = Hi, C Tap Connector = C1. DC Tape Clip -H2. Surge Arrester = €2. Tape Clips, -H3. Gable Lug = C3. Bi ~ Metallic Connector 16 -H4. Grounding Cable 09D. Clamps Fixings = D1. Square Tape Clama - D2, Plate Type Test Clamp 10. E. Bonds Fixings ~E1, B Bond -E2, RWP Bond (Green-Yellow or Green) = H5, Earthing Improvement Compound = HE. Exothermic- Welding ATEG Lightning & Earthing Protection. Lightning, 2 common phenomenon happens in Malaysia, especially during the monsoon periods. But how much do we know about lightning? Lightning can actually be defined as the discharge produced when differences between ground and atmospheric electrical charges are large enough to overcome the insulating effect of the ai. Lightning can occur within cioud, cloud to cious, and between cloud ‘and grounc. The destruction causes from lightning Lightning can provide a spectacular display of ight on a dark night. However, this awesome show of nature can bring fierce destruction than many other natural disastrous. The destruction can either bring direct effects or indirect effects. The direct effects are from resistive (ohmic) heating, arcing and buming, Wheroas, the indirect effects are more probable, which include capacitive, inductive and magnetic, behaviour. Thus, lightning can induce fires, damage electrical installations, and more important it kills, Installations where lightning protection is highly recommended to the following areas (summary) : Airports, shipping, hospitals, shopping mall and ate. Buildings containing computers and electronics, Explosives factories and storage areas. Flammable liquid or chemical storage. Factories and industrial plants - such as chemical, textile, paint and etc. Golf courses, race courses, sport arenas, stadiums, etc. Historie structures, mosques, and etc. High rise commercial buildings, complexes, apartments and et, Mining areas. Miltary installations. Oil and gas storage and refinery. Power stations, sub-stations and transformer stations. Radio towers, telecommunication stations and ete, ney rine The shataring eft rom a igri sie Universities, colleges - education facilities ‘oem thestarcom myfspecaoninethartonaiseaulthim) Parcrespespapee Malaysia - A Rainforest Country Rich Of Thunderstorm Melaysia, @ beautiful country that covered with rainforest, is opposed to 100 - 140 thunderstorm days per year (As refer to Figure 3.0). As dividing if, it would be approximately 8.3 - 11.6 thunderstorm days per month, which is very much than the thunderstorm days per annum in Antarctica and Artic. According to Malaysian Meteorological Service's analysis from 1951 to 1998, the highest number of days with lightning being recorded was 329 days per annum (www.kje.gow.my/people/kliminterest him). This record was recorded at its Subang station, Selangor. Thus, it would be a need for us to install a proper lightning protection system because lightning strikes all exposed things on the ground, such as bulidings, storage tanks, trees, hiltops and etc, Thunderstorm Days Figure 3.0 Word Thunderstorm Days Por Yoar 04 Introduction ATEG Lightning & Earthing Protection Structural Lightning Design Consideration As Accordance To BS 6651:1990 ‘The principal components of a lightning protection system are as below (summary) Air Termination Network Air termination networks can either be vertical or horizontal conductors or the combination of both. For most of the common structures, an air termination network mash af approximately ‘mir x 20mir with provision of no part of the roof should be more than Smir from the closest horizontal conductor are considered efficient for protection from lightning strikes. However, for structures contain highly flammable or explosive contents, the horizontal conductor mesh should be Smtr x 10mtr, with no part of the root should be more than 2.5mtr from an alr termination conductor. Down Conductors Generally, down conductor is used to provide a low impedance path trom the air termination direct to the earth electrode in order the lightning current can be safely conductad to the earth, ‘The down conductor should be routed as directly as possible between the air termination network and the earth termination network. ‘As according to BS 68511990, it recommended one down conductor is to be used for every ‘20mtr or part thereof of the perimeter at the roof level or ground level, whichever is greater, However, if the building siructure Is above the height of 20mtr or of an abnormal risk, the distance between one to another should be reduced to 1Ormtr. * Tost Joint {tt should be recommenced that each down conductor should require a test joint 2s convenience {or test purposes.) [Ae Termination Bonde {fo tee Reinforeng Or ‘Stee ame OF Buidng Earth Termination Network ng Ein Eee 7 77| | Toimprove Eating am Biectiove | igure 0 fing Eatin sectrose 02 Introduction Figure 40 Explosvelriammaote stueture Newark Mesh Every earth electrode should connect wilh a separate down conductor. Each of the ‘earth electrodes should have a resistance (ohm) nat more than 10 times the total of ‘earth electrodes to be provided. Moreover, the total resistance of the complete earth termination network should not exceeding 10 ohms. However, if the resistance of the complete lightning protection system more than 10 ‘ohms, the resistance can be reduced oy implementing the ring earth electrode. I is important to understand that a reduction in resistance below 10.chms can lowered the Tisk of side flashing as well as reduce the potential gradient around the earth Rapeart Restone ‘electrodes when discharging lightning current, ATEG Lightning & Earthing Protection. Lightning & Earthing Protection System Installation Drawing A. Air Terminal Fixings D. Clamps Fixings G, Conductors ~A1, Taper Pointed Air Rod = D1. Square Tape Clamp = G1, Bare Copper Tape - A2, Multiple Taper Pointed Air Rod - D2, Plate Type Test Clamp - G2. Bare Aluminum Tape = A3. Air Terminal Base - G3. Bare Galvanized Stee! Wire + Ad, Ridge Saddle E. Bonds Fixings - G4. Flexible Bare Copper Braid ~E1. B Bond B. Roofing Conductor Fixings + E2. RWP Bond H. Supporting Accessories = B1, HDG Roofing Mount Support Hook = H1.C Tap Connector (N= Hook) F. Earthing Accessories -H2, Surge Arrester = 82. HDG Roofing Mount Support Hook = F1. Copper Rod = H3, Cable Lug (A- Hook) = F2. Coupling = H4, Grounding Cable - B3, Slate Holdfasts Support Hook -F3, Driving Stud (Green-Yollow or Groen) - B4, Slate Holdfasts Support Hook With - F4, Earth Ros To Tape Clamp (Type A) - HS. Earthing Improvernent Compound L- Shape -F5. GUY Type Rod To Cable Clamp = H6. Exathermic- Welding = 85. Compound Type Roofing Support F6. Earth Bonding Points ‘Accessories -F7. E Type U Bolt Rod Clamp - B6, Teflon Block -F8, Earth Boss - B7. Expandable Support Hook -F9. Earth Bars p + BB, Bott & Nut - F10, Concrete Earth Chamber ., | CFM Earth Bar | Y y ©. Conductor Fixings = C1, DC Tape Clip = C2. Tape Clips. - C3. Bi Metallic Connector 03 Introduction A. Air Terminal Fixings Wiehe Rte ‘AA. Taper Pointed Air Rod Rod Length ‘Thread Diamotor Material Product Code 500 me 16mm ‘Copper ATG 050, "1000 ram 46 mm ‘Copper ‘ATG 109 ‘A2, Multiple Taper Pointed Air Rod ‘Thread Size Height Material Product Code M6 500 mm ‘Copper MATS 050 Mie $1000 mm ‘Copper (MATS 100 ‘AS. Air Terminal Base ‘Thread Diemeter__Maximum Conductor Width Material _Product Code sem 25 mm ‘Copoer ‘ATBG 160 ‘Ad, Ridgo Saddle ‘Thread Diameter Maximum Conductor Width __Msterial__Product Code 16 mm Sto ‘Copper RSBG 160) 04 Products Introduction ATEG Lightning & Earthing Protection. B. Roofing Conductor Fixings 81. HDG Roofing Mount Support Hook (N Hook) with (A) with Height Mote oduct Code. 200 mm 37 mm 300 HDG Steel NHG 2037, 182, HDG Roofing Mount Support Hook (A - Hook) Thickness Mate oduct Code 25cm 250 mn me HDG Stoel ‘ANG 2525 “ 05 Products Introduction B. Roofing Conductor Fixings Lightning & earthing roca 183, Slate Holdfasts Support Hook Width (A) Thickness Material Product Code 25 mm 1160 mm 3mm ‘Aluminum SHG 253, he Es a BA. Slate Holefasts Support Hook With L - Shape Width (A) __Longth __Thickness__H Material Product Code 25mm 160mm Sm 20mm Aluminum ———_~SLG-269) 86. Compound Type Roofing Support 06 Products Introduction oe & Earthing Protection. B. Roofing Conductor Fixings 'B6. Teflon Block Dimension Thickness Thread Size__Golor__Material_Product Code 25%25mm 15mm M6: ‘White Teflon TFG 015 38438 mm 25 mm M6. White Teflon TFG 025 7. Expanclable Support Hook wiath Length “Trvead Size Material Product Code 25 mm 200 mm M6. ‘Aluminum Ea 002 38. Bolt & Nut Product Type: Size Product Code Hexagon Head Screw Me x8 rim HHG 068 Round Head Screw MB x8 mim RHG 068 (Counter Sunk Set Screw Mx 8 mm (056.068, Burtery Serew 6x30 mma 5G 068 Hexagon Nut NG. Slainless Steet 886 008 07 Products Introduction ATEG C. Conductor Fixings Lightning & Earthing Protection 1.06 Tape Clip Conductor Size Material Product Code 25% mm Copper oe 253 25 x6 mm Copper ee 256 50% mm Copper oe 503) 0x6 mm Copper DCG 506, 2. Tape Clips Product Code Conductor Size Material 253 mm Copper TOG 253 ALTG 253 fee) ~ ~ 63. 81- Metallic Connector Product Gode Conductor Size Material BMG 259) 25%3 mm ‘Copper & Alurinium 08 Products Introduction ATEG Lightning & Earthing Protection. Di. Square Tape Clamp D. Clamps Fixings Conductor Size Material Product Code 253 mm Copper STG 259 25x6 mm Copper STG 256 0x6 mm Copper STG 506 2 Plate Type Test Clamp Conductor Size Product Code 26% 12 mm PTCG 2612 09 Products Introduction E. Bonds Fixings a ATEG Lightning & Earthing Protec 1.8 Bona Max Tap With ot size atria Product Code 26 0 Compe 128506 2610 2, RWP Bond Max Tape with Bot size Matt Produet Code Zim wo cana HPO 2610, 10 Products Introduction F. Earthing Accessories Dimensions ‘Congth Product Code 1200 mm (CRG 1612 "1500 mm GAG 1615 "1800 mm ORG 7616 1200 mm CREDO 71600 mm CRG2076 F2, Coupling Nominal Rod Diameter Product Code sie PG 062 3H (PG 075 F3, Driving Stud Nominal Rod Diameter Product Cod: sre CPG 062 30 PS 0 Conductor Size Product Cod: © Tape Clamp (Type A) 25 sn ERG 1625 sre ism) Sm CRT Sse oan) SSS SSCS~S~SiRG IS se ommy mm CREO 14 Products Introduction ATEG F. Earthing Accessories Lightning & Earthing Protection F5. GUV Type Rod To Cable Clamp. Nomi Conductor Rang oduct Code 16-95 mm? GuvG 1637 16-70 mn? euve 2037, 6, Earth Bonding Points __Product Description __Conductor At Front Plate __—_—Preduct Cod ! shoes Tm CPO FT. E Type U Bolt Rod Clamp ¢ 6. Earth Boss Nominal Rod 7 Hole Centres___Tape Width _Product Code. ra ‘7 mm : BG 1697 3/8) ‘a7 mm 25 mm UBG 1637 are ‘ST mm 7 UBG 2037, NEES 412 Products Introduction ATEG Lightning & Earthing Protection. Earthing Accessories 9. Earth Bars, Terminations. ‘size (mm) No OF Dise Links _ Product Code 6 4H) x 6(7 x 25044 : EBBG 006 8 404) x 6C7) « 35004) - EBBG 008 70 40H) x 6(7) x 46004) - BBG 010 72 404} x 6CT) x 4600) BBG 012 2 5H} x 6(7} x 490() BBG 020 6 40, x 6(7) x 601) 41 E856 061 6 -40(H) x 6(T) x 46000) 2 EBBG 062 e@ F10. Concrete Earth Chamber Overall Dimensions, Product Code 262 x 282 x 195(H) mm IPG 282 828 x 828 x 220(H) mim IPG 828 Ft. Earth Bar Product Dosctiption Product Code 5 Holos BG 005, @2eee6e 13 Products Introduction ATEG G. Conductors Lightning & Earthing Protection G1. Bare Copper Tape Conductor Size 25% mm 256 mm '50%3 mm ‘506 mm 62. Bare Aluminum Tape Conductor Sizo Product Code, 25%3 mm BAG 253 G3. Bare Galvanized Steel Wire [Nominal Strand Diameter ‘Stranding No. Product Code 6.00 mm 72.00 mim BGG 0600 7.95 mn 772.65 mn" BGC 0800 975mm 773.25 mm BGG 1000 120mm 714.00 mm BGG 1200 * Other sizes also avallable upan request. G4, Flexible Bare Copper Braid Conductor Size Product Code extmm FBG 0601 12x15 mm FOBG 1215 162mm FOBG 1602 25 x 2mm FOBG 2502 35x30 FOBG 3503 ATEG Lightning & Earthing Protection. H. Supporting Accessories Hf. Tap Connector Cable Size Material Product Code 38 mm? :4—25 ma Copper Yyo2 04 50-70 mar: 18-35 mime ‘Commer yo26 C2 50-70 mar 35-70 mm ‘Copper ‘¥o25 026 (8S mm: 95 mm ‘Copper ‘¥o28 028 ~ Other sis also avaiable upon request H2, Surge Arrestor ‘Type 4 timp (10/850 us) / Imax (820 ps} limp J imax Connection Product Code 151A! 100 KA. Three chase (wityeserve) _OVRHL4L 15 4408P TS 151A 100 KA. ‘Single pole (with reserve) (OVR HL AL 440s P TS * Other ratings also avaliable pan request. Imax. Connection Product Code 100K Single pole (phase) (Ove 1002758 PTS 100 KA Single pole (neutral) (OVR 100NP O5KA “Three phase (with reserve) OVR 3N-65.2755 P 40KA Three phase (OVE 240.275 P 15KA Three phase (OVR SNA5275P GSKA Single phase (with recone) OR 1NB5.2755 P AOA Single phase (OVI IN-40.275 P 15 KA Singla phase (OVRINTS275P * Other ratigs also avaliable upon reauest. H3, Cable Lug Cable Lug Sizo Product Code Onn! x MB C16 5008) 50 mre x MIO (615010) SO mene M2 cus 5012, Tome x 48 618 7008 Tome x M10) LS7010 7omme x2 CL TOT 85 me xB CLG $508, 35 mere x MIO. cls e810 a5 mere x M2 cls e512 7 Other sizes also av lable upon request 415 Products Introduction ” ATEG H. Supporting Accessories Lightning & Earthing Protection 4. Grounding Cable (Green-Yellow or Green) Cable Size 3Cx6 mae 10 25 mm TEx 80 ma Cx 70 mmr 10 95 mm 16120 mn 16 «150 men ~ Other ratings alsa avalable upon request * Green Yellow Heat Shrink is avaiable upon request 5, Earthing Improvement Compound he Ks Product Cod 2 EMIX-20, 2 EMIX25 H6, Exothermic-Welding ftom Description Exothemic Welding Mould ‘Tape: To Tape Joint Type Exothermic Welding Mould “Tape To Cable Joint Type Exotnermie Welding Mould Gable To Gable Joint Type. Exotherie Welding Mould Cable To Grounding Rod Joint Type Excthermic Welding Mould “Tapo To Grounding Rod Joint Type Welding Powder 659 Welding Powder 09 Welding Powder 789 Welding Powder 1509, Ignitor Gun To Ignite The Welding Powder Mould Soar “To Prevent Mould Leaking Exothernie Welding Clamp “Small, Medium, Large Type ‘Other range of products also avaliable upon request * Please cel for futher cecication. 16 Products Introduction ATEG Lightning & Earthing Protection Partner Axthortend Dietriputer : "Any ober types & Sizes ave avaliable pon quest Kinyo contact with our technical perten

You might also like