IP Addresses
Device IP-Address Sub net
XG-8700L (Linescan) 190.Mac-IP.50.1 255.255.0.0
XG-8000P (Tape,Highloft) 190.Mac-IP.50.2 255.255.0.0
XG-8000P (Fr-Tape, EWB/Barrier) 190.Mac-IP.50.3 255.255.0.0
Program
Workplace is only on SD1 (SD2 is used only for image store and main settings)
1) Create a new program number by clicking "Next Available No. (S)"
2) Press "OK" and edit the name of the program
5.1 Select the scale for the y-coordinate and and the
length
Scales are predefined for he following
sizes:
(can be extended -> global variables)
$Y_Skalierung_Mini
$Y_Skalierung_Midi
$Y_Skalierung_Maxi
$Y_Skalierung_Junior
$Y_Skalierung_XL
By writing "$" in the selection box, the
choices of the scaling will appear auto-
matically. Scaling numbers will change
automatically.
Do not change the values!
Region: Adjust the position and the size of the controlled area
Image Enhance: Display in the test window (adjustment via brightness, contrast,...)
Edge Filter: Illustration of the search edge (light <-> dark), adjustment and settings
when this edge is recognizable and when sufficient for the analysis.
Tolerance: Range incl. upper lower signal. Range is in yellow, green and red
color (Adjustment are much easier with the controller)
There are two possible adjustments. The size (Width / Height) of the control area can
be adjust or only the position (X / Y) of the control area. Normally only an adjustment
of the position X or Y is sufficient.
Both sides should be on the same high level, therefor note the coordinates in y-direction.
Example:
In this example an edged will search in the control area from light to dark, form left to
right. The determined value is 202.7. The upper value for the edge intensity is 255 and
6.7 Limits
In the tab Limits, the current measured value is displayed during the operation. Addi-
tional adjustment option for the limits range can be set here.
It is much easier to adjust this values for the tolerances directly on the panel with the
controller!
An additional option to adjust the visible is the Contrast Converter to get the best
possible image or edge.
1) Settings (S)
2) Update Reference Position from Registered Images (R)
This update is necessary so that all settings and adjustments are also accepted and up
to date!
1) Tools (T)
2) XG Simulator (U)