Quality Solutions (India) ‘ACCREDITED BY NABL (Deptt. of Science and Technology-Govt. of india) CALIBRATION CERTIFICATE ‘CUSTOMER : MIS, SHREE RADHEY TECHNOLOGY §.19 & 20, RIICO INDUSTRIAL AREA BINDAYAKA, JAIPUR (RAJ) | Date of Performance : | 20/03/2018 Certificate No. 2 | QSV2315/18/03, Servide Request No, : | QSU2315/18/03 | Service Request Date + | 20/03/2018 Page ia Total Page 2 Unit Under Calibration PROFILE PROJECTOR | Environment Temperature : | 20°c41°C Calibration Procedure QSI/QP/S.4/01.WI-34M | Relative Humidity(%RH) : | 6010) % Visual Inspection 2 | OK Location of calibration AtSite DETAILS OF UNIT UNDER CALIBRATION | Make/ Model Range LC. ‘Sr.No. | ACGUTECH XCAXIS- 0-120 mm 0.007 mam 040 VT-250 Y-AXIS -0-100mm 0.001 mm, | 0-360 Deg. 1 Sec. | Magnification-10X.100X_| DETAILS OF STANDARD EQUIPMENTS USED FOR CALIBRATION Name Make Sr.No. /ID.No. | Certificate No. | Validity | Calibrated By ‘STEEL GAUGEBLOGR | TRUSIZE ‘OSISGOS | —REPIOTTIS T7106 —] —garowROIe | Traceable w NPL, | set through NABL LAB | __ceabe-o. 7 C32 | “ANOLE GAUG NaRRONIX | ~RSSTAGTOT | KCPSRTTTTGOOS | TITOROTS | “Traseabl to NPT, though NABL LAB Con Digital Caliper PRSISE ‘QSUDCIO | HILSATIQSIATEOS | 227062018 | Tecate w NFL. | through NABL LAB a | -0600 (HTLS) | OBSERVATIONS REFER 2nd Page Calibrated By Issued By Shri Ram Dhiman Ajay Kumar Singh | echnical Executive) (Technical Manager) Quality Solutions (India) = "ACCREDITED BY NABL (Dept. of Science and Technoiogy-Govt. of india) on a ) CUSTOMER : M/S. SHREE RADHEY TECHNOLOGY S19 & 20, RIICO INDUSTRIAL AREA , BINDAYAKA , JAIPUR (RAJ.) feo | Date of Certificate No. Suggested Page No. of , ___ Calibration Due Date Page . 20/03/2018 (QS1/2315/18/03, + 20/03/2019 2 2 OBSERVATION :- X-AXIS Y-AXIS ‘Sr No. | Std. Reading UU. Sr.No. | Std. Reading (mm) Reading(mm) (mm) {91 000.0000 000.000 01 000.0000 000.000 oy (001.0000 001.000 02 (001.0000 004.000 03, 010.0000 010.001 03 010.0000 010.001 | 04 020.0000 020.001 [04 [020.0000 020.001 05 050.0000 (050.001 05 050.0000, 050.001 06 | 100.0000 100.001 06: (080.0000 (080.001 Lo 120.0000 120.001. o7 100.0000 100.001 ANGLE MAGNIFICATION Sr.No. | Std. Reading U.U.C. | Magnification | Std. Value Observed — | - Reading Set on U.U.C (mm ) Value-mm o1 | v0or74r | 1870076" 40X 5.00 50.00 02 | 3070071667" | 30700775" 10x | 2.00 200.00 03. | 457007969" | 457700708 04. | S07 0T 0400" | 8OTOOTOR MAGNIFICATION ERROR : Nil U.U.C, : UNIT UNDER CALIBRATION Traceability of Standard{(3) : The Standard Used for calibration is traceable to National Standards Uncertainty of Measurement (At approximately 95% Confidence Level, k=2) X/Y Axis Movement = +0,004: Angle = + 24 sec. 3mm Magnification= + 0.8 %of rdg. Cali or Shri Ram Dhiman (Technical Executive) Issued By Ajay Kumar Singh (Technical Manager)

You might also like