Professional Documents
Culture Documents
detect 3000 Safety without The detect 3000 portfolio offers flexible, cost-
effective solutions for small, medium and large
Compromise
scale applications including products ranging
from detectors to panels and networked
The international detect 3000 system was systems with visual detect graphic displays.
developed from the consolidation of the JOB-
Group in 2003, when detectomat became
part of the group and launched it’s detect system features and benefits:
3000 system as a fire fighting technology
solution. • detect 3000 fire control panels for
all applications
Technical data
Properties:
Clear display and easy operation via 5,7" Touchscreen-Display, 320 x 240 pixel
Integrated 1 loop-interface for the connection up to 126 loop devices of the loop3000 series
Integrated USB-interface for the easy programming via DCT-software
RS 485-interface for external printer
Integrated primary switched power supply 150 W according EN 54-4 / A2: 2006
1 output 400 mA for external user
3 potentialfree relay outputs for alarm and fault
2 freely programmable monitored inputs
1 monitored output 24 V / 400 mA for signaling devices (sounder, flasher, etc.)
Event memory of up to 9999 events
Up to 999 programmable zones
Custumer specific texts for zones or detectors with up to 40 characters
Programmable reaction and inspection times
Integrated alarm buffer and 2 detector / 2 zone dependencies
2 integrated languages (German, English)
Input voltage 84 - 264 V AC / 120 - 300 V DC / 47 - 63 Hz
Power supply 32 V DC / 150 W / 3,5 A
Emergency backup 2 batteries 12 V / up to 12 Ah
Interfaces USB, RS 485
Display 5,7" Touchscreen display 320 x 240 pixel, integrated backlight
LEDs 18 LED - indicators for status messages
Outputs 1x 24 V / 400 mA monitored line for alarm devices (sounder, flasher)
3 relay outputs 30 V / 2A for alarm and fault
Inputs 2 freely programmable monitored inputs
Ambient temperature 0°C to +50°C
Humidity 5 % - 95 % (non-condensing)
Protection class IP 30
Colour Light grey RAL 7035
Material Stainless Steel
Dimensions (H x W x D) 300 mm x 400 mm x 135 mm
Weight 12 kg, without batteries
Standards EN 54-2:1997/A1:2006
EN 54-4:1997/A1:2002/A2:2006
VdS approval G208123
System approval S295054 and S208123
2. Fire Control Panel detect 3004 plus and accessories 4
plus
Fire Control Panel detect 3004 , deep housing, language kit English
Art.-no. 32551 - Type detect 3004plus M GB
Fire Control Panel detect 3004 plus, shallow housing, language kit English
Art.-no. 32553 - Type detect 3004plus S GB
Description:
Microprocessor controlled modular fire control panel for
the use with the loop3000 fire detection system
components. Approved according to EN54-2 A1:2006,
EN54-4 A1:2002, A2:2006 and VdS for the use according
to VdE 0833.
Technical data
Properties:
Large LCD, 160 x 80 with backlight
Integrated Display and Control Panel according to DIN EN54-2 A1:2006
2 slots for 2 loop-interfaces for the connection of up to 4 loops each with a maximum of
126 loop3000 devices per loop and a maximum loop length of up to 3.500 m
Option for 2 conventional interface cards for controlling up to 16 conventional zones
Extinguishing interface for controlling extinguishing and gas suppression systems in accordance
to EN12094
Integrated control of extinguishing systems via the standard extinguishing interface in accordance
to VdS
Connections for a fire brigade interface for controlling the panels outputs, key deposit
and transmission units
Integrated interface connection for up to 63 additional network components
Integrated RS 232-interface for the DPT programming software and the connection of printers
and other peripheral equipment
Integrated power supply 72 W according to EN54 with 1 output
for external devices rated at 24 V DC/800 mA
Monitored power supply unit and battery charging according to EN 54-4 A1:2002 and A2:2006
via the MC 3004 monitoring card
1 external output 24 V/400 mA monitored for sounding/signalling devices
3 potential free relays for fire and fault
3 inputs for collective signals
Emergency power supply via 2 batteries 12 V/up to 12 Ah (shallow housing) / 26 Ah (deep housing)
Integrated ground fault monitoring
Segmented front door allowing the quick assembly of LED indicator modules and printers
Option for customised front logos
In accordance to EN61000-6-3 class B for emissions, so suitable for the use in sensitive areas
Possibility for complete system redundancy with the CPU and loop interfaces
Up to 128 programmable detector zones
Up to 42 T-branches per loop possible
Event log memory of up to 500 messages
For more technical details please see next page.
2. Fire Control Panel detect 3004 plus and accessories 5
Fire Control Panel detect 3004 plus, deep housing, language kit English
Art.-no. 32551 - Type detect 3004plus M GB
Fire Control Panel detect 3004 plus, shallow housing, language kit English
Art.-no. 32553 - Type detect 3004plus S GB
Technical data
Properties:
Programming of control logics and time dependent functions for the components of series loop3000
Customized customer texts allowing up to a maximum of 20 characters
Simple menu structure in accordance to EN 54-2 A1:2006
Integrated alarm buffer and 2 detector/zone dependencies
Time controlled changeovers of sensitivity levels of loop3000 detectors by day/night modes
Software controlled disablements for zones and individual detectors via external inputs
Ability to change and edit inspection and reaction times along with all delays
Programming options for different alarm modes
Different access levels with password protection
Integrated "one-man-revision mode" with clear protocols and a revision counter
Visual diagnostics and remote-control operations via the visualization software visual detect
Commissioning and service tool for analyzing and fault finding functions with I-Check software
Incl. English language kit for control and programming
Supply voltage 230 V AC (-15 %/+10 %)
Power supply 24 V DC / 72 W / 3,5
1 output 24 V DC/800 mA for external devices
Emergency supply 2 x 12 V/12 Ah (shallow housing) 26 Ah (deep housing)
Quiescent current 250 mA
Alarm current 400 mA
Interfaces RS 232; Bitbus (RS 485 based)
Display LC-Display 160 x 80 points, backlight
20 LED-display for status signal
Outputs 1 x 24 V/400 mA monitored for sounding/signalling devices
up to 4 loop 140 mA/3500 m for up to 126 loop3000 elements each
3 relays outputs 250 V / 5 A for alarm and fault
8 open collector outputs 30 V DC / 90 mA
Inputs 3 inputs for collective signal
Ambient temperature -5°C to +40°C
Humidity 5 % - 95 % (non-condensing)
Protection class IP 30
Colour Light grey, RAL 7035
Material Sheet steel
Dimensions (H x W x D) 490 mm x 420 mm x 150 mm ( shallow housing)
490 mm x 420 mm x 210 mm ( deep housing)
Weight 12,5 kg, without batteries
CPD-Number 0786-CPD-20817
VdS approval G203068
System approval S295054
Standards EN54-2:1997 A1:2006; EN54-4:1997 A1:2002 A2:2006
Further approvals EN12094 for 1 area extinguishing systems
international approvals on request
General remarks Scope of delivery without loop cards, network interfaces and batteries
Utilization of integrated standard extinguishing interface requires 1 op-
tional LED indicator module in the front for indication acc. to EN54-2
2. Fire Control Panel detect 3004 plus and accessories 6
Technical data
Properties:
Suitable for all fire control panels of the series detect 3004plus and the remote display control panel
For the triggering of a fire brigade control board, an transmission unit and a key deposit box
Switching possibility for the monitoring current of the monitored output from 2 mA to 10 mA
Connection of the swiss fire brigade control panel via 20 pole ribbon cable
Integrated protection for the monitored output and the operation voltage
Connection directly to the CPU-main board via 26 pole ribbon cable (included in the scope of supply)
Operation voltage 20-28 V DC via detect 3004plus supply
Emergency current supply via detect 3004plus supply
Quiescent current Approx. 15 mA (without key deposit box and fire brigade control panel)
Alarm current Approx. 57 mA (without key deposit box and fire brigade control panel)
Outputs 8 open collector 90 mA
3 x 24 V operation voltage
400 mA moitored
Inputs 8 x low active
Ambient temperature -5°C to 40°C
Humidity 5 % - 95 % (non-condensing)
Dimensions (H x W x D) 160 mm x 75 mm x 25 mm
Weight Approx. 140 g
VdS approval With detect 3004plus
System approval S295054
Further approvals International approvals on request
General remarks The main relay reacts according to the monitored output of the UEI
in case of mounted UEI-card
2. Fire Control Panel detect 3004 plus and accessories 7
Extinguishing Display Board for the Fire Control Panel detect 3004 plus
Art.-no. 32559 - Type EXT 3004 plus
Description:
Display board for mounting into the fire control panel
detect 3004plus for the indication of different messages of
the integrated standard-interface-extinguishing
Technical data
Properties:
LED - displays of the integrated standard-interface-extinguishing
for the activation, feedback, fault and disconnection
For the mounting into the LED indicator mounting plate (32560) of the detect 3004plus
The display board extinguishing is mounted on the mounting place of the first LED indicator module
and is completely controlled by the MC-Card
Including labelling strips for the identification of different messages
Assembly kit is included in the scope of delivery
Ambient temperature 0°C to + 40°C
Dimensions (H x W) 80 mm x 43 mm
General remarks To ensure a display for the standard interface extinguishing according
to EN54-2, this display board has to be integrated into the
fire control panel detect 3004plus
Mounting Plate for Display Extinguishing Interface and Printer for 3004 plus
Art.-no. 32560 - Type CP MP 3004 plus
Description:
Mounting plate to plug into the front door of the fire control
panel detect 3004plus for the use of LED indicator
modules, mount in printers and/or extinguishing display
board
Technical data
Properties:
Mounting of up to 6 LED indicator modules (30088)
Including labeling windows for the individual detector zones
In case of the mounting of an extinguishing display board (32559)
there are still 5 additional mounting slots for LED indicator modules
The protocol printer (32558) can easily be integrated into the mounting plate
thanks to a factory provided precut
Colour RAL 7046 tele grey
Material Sheet steel
Dimensions (H x W) 228 mm x 365 mm
Weight Approx. 0,7 kg
VdS approval with detect 3004
System approval S295054
Weight Approx. 0,7 kg
Standards EN54-2, -17
2. Fire Control Panel detect 3004 plus and accessories 8
Mount in printer for the fire control panel detect 3004 plus
Art.-no. 32558 - Type PIP 3004 plus
Description:
Thermo-printer for the integration to the front plate of the
detect 3004plus fire control panel
Technical data
Properties:
Direct connection to the RS 232 Interface of the fire control panel
32MB of Integrated Buffer Memory
Thermoprint with fixed print heads
204 DPI Resolution
57mm paper width
Printing speed of 50mm/sec
Powered directly from the detect 3004plus fire control panel
Operation voltage 10 - 32 V DC
Quiescent current 100 mA
Alarm Current 200 mA
Interface RS 232
Print ASCII Standard, international character set
Paper width 57 mm, Paper roll diameter 50 mm
Ambient temperature 0°C to 50 °C
Humidity 10-85 % (non-condensing)
Colour Black
Material ABS
Dimensions (H x W x D) 85 mm x 85 mm x 57 mm
Weight 141 g
General remarks Installation of this printer requires the mounting plate MP 3004
Thermo-paper for PIP 2 and PIP 3004 plus, packing unit 5 rolls
Art.-no. 30107 - Type EP 5
Description:
Thermo-paper, packing unit 5 rolls
Technical data
Properties:
Suitable for mount in printer PIP 2 and PIP 3004plus
Packing unit 5 rolls
Paper width 57mm
Outer diameter: 37mm
Inner diameter (bore) 12,3mm
3. Fire Control Panel detect 3004 and accessories 9
Fire Control Panel detect 3004, deep housing, language kit English
Art.-no. 32421 - Type detect 3004 M GB
Fire Control Panel detect 3004, shallow housing, language kit English
Art.-no. 32424 - Type detect 3004 S GB
Description:
Microprocessor controlled modular fire control panel for
the use with the loop3000 fire detection system
components approved according to EN 54 and VdS for the
use according to VdE 0833
Technical data
Properties:
4 alphanumeric lines LC-display with backlightt
Integrated display and control panel according to DIN EN 54
2 slots for 2 loop-interfaces for the connection of up to 4 loops with a maximum of
126 loop 3000 devices per loop and a maximum loop length of up to 3500m
Option for 2 conventional interface cards for controlling up to 16 conventional zones
Extinguishing interface option for controlling extinguishing and gas suppression systems
in accordance to EN12094
Option for control of extinguishing systems via the standard extinguishing interface in accordance
to VdS
Connection option for a fire brigade interface for controlling the panels outputs, key deposit
and transmission units
Integrated interface slot for the connection for up to 63 additional network components
Integrated RS 232-interface for the DPT programming software and the connection of printers
and other peripheral equipment
Integrated power supply 72W according to EN54 with 1 output
for external devices rated at 24VDC/800 mA
1 external output 24 V/400 mA monitored for sounding/signalling devices
3 potential free relays for fire and fault
3 inputs for collective signals
Emergency power supply via 2 batteries 12 V/ up to 12 Ah (shallow housing)/ 26 Ah (deep housing)
Integrated ground fault monitoring
Segmented front door allowing the quick assembly of LED indicator modules and printers
Option for customised front logos
Possibility for complete system redundancy with the CPU and loop interfaces
Up to 128 programmable detector zones
Up to 42 T-branches per loop possible
Event log memory of up to 500 messages
Programming of control logics and time dependent functions for the components of series loop3000
Customized customer texts allowing up to a maximum of 20 characters
Integrated alarm buffer and 2 detector/zone dependencies
For more technical details please see next page.
3. Fire Control Panel detect 3004 and accessories 10
Fire Control Panel detect 3004, deep housing, language kit English
Art.-no. 32421 - Type detect 3004 M GB
Fire Control Panel detect 3004, shallow housing, language kit English
Art.-no. 32424 - Type detect 3004 S GB
Technical data
Properties:
Time controlled changeovers of sensitivity levels of loop3000 detectors by day/night modes
Software controlled disablements for zones and individual detectors via external inputs
Ability to change and edit inspection and reaction times along with all delays
Programming options for different alarm modes
Different access levels with password protection
Visual diagnostics and remote-control operations via the visualization software "Visual detect"
Commissioning and service tool for analyzing and fault finding functions with "I-Check" software
Incl. English language kit for control and programming
Supply voltage 230 V AC (-15%/+10%)
Power supply 24 V DC / 72 W / 3,5
1 output 24 V DC/800 mA for external devices
Emergency supply 2 x 12 V/12 Ah (shallow housing) 26 Ah (deep housing)
Quiescent current 86 mA
Alarm current 146 mA
Interfaces RS 232
RS485 and Bitbus as option for network
Display 4 alphanumeric lines LC-display, backlight
20 LED-display for status signal
Outputs 1 x 24 V / 400 mA monitored for sounding/signalling devices
up to 4 loop 140 mA / 3500 m for up to 126 loop3000 elements each
3 relays outputs 250 V / 5 A for alarm and fault
8 open collector outputs 30 V DC / 90 mA
Inputs 3 inputs for collective signal
Ambient temperature -5°C to +40°C
Humidity 5-95 % (non-condensing)
Protection class IP 30
Colour Light grey, RAL 7035
Material Sheet steel
Dimensions (H x W x D) 490 mm x 420 mm x 150 mm ( shallow housing)
490 mm x 420 mm x 210 mm ( deep housing)
Weight 12,5 kg, without batteries
VdS approval G203068
System approval S295054
Standards EN 54-2: 1997
EN 54-4: 1997
Further approvals EN 12094 for 1 area extinguishing systems
international approvals on request
General remarks Scope of delivery without loop cards, network interfaces and batteries
3. Fire Control Panel detect 3004 and accessories 11
Technical data
Properties:
Suitable for all fire control panels of the series detect 3004 and the remote display control panel
For the triggering of a fire brigade control board, an transmission unit and a key deposit box
Integrated protection for the monitored output and the operation voltage
Connection directly to the CPU-main board via 26 pole ribbon cable (included in the scope of supply)
Monitored connection for transmission unit (programmable)
Control unit for transmission unit, main alarm relay and delay
Display board available under Art.-no. 30090
Ambient temperature 0°C up to + 40°C
Dimensions (H x W) 75 mm x 159 mm
4. Accessories for Fire Control Panels detect 3004 and detect 3004 plus 12
1 Loop - interface, active, 140 mA for detect 3004 and detect 3004 plus
Art.-no. 32254 - Type DLI 3120P X1 - 1L
Description:
Microprocessor controlled loop interface for the
uninterruptible and short-circuit-proof use with the
loop3000 fire detection system components for the
connection of 126 fire detection system components on
one loop or 2 spurs
Technical data
Properties:
Connection of loop3000 components in loop structure or spur-structure
2-wire-system-loop with up to 3.500 m loop length, (using wire lead JY(St)Y 2x2x0,8mm)
Easy and flexible installation and initialization via automatic and manual addressing
Integrated RS 232-interface for an easy analysis of the loop components,
the preadjustment of functions and commissioning of loop3000
8 integrated freely programmable open-collector-alarm outputs
2 integrated open-collector-alarm outputs for the programming of collecting functions
Supply via fire control panel detect 3004
Integrated short circuit isolaters on all loop outputs
Up to 42 T-branches per loop possible
Commissioning and service tool for analyzing and fault finding functions with "I-check" software
Supply voltage 20-28 V DC via detect 3004 supply
Emergency supply via detect 3004 supply
No load current 40 mA
Quiescent current Depending on the loop structure-max. 120 mA
Alarm current Depending on the loop structure-max. 250 mA
Interface 1 x RS 232
Outputs 1 Loop 140 mA / 3500 m for up to 126 loop3000 devices
alternatively 2 spurs
2 freely programmable monitored inputs
2 open collector outputs 30V DC / 90 mA for alarm and fault
8 open collector outputs 30 V DC / 90 mA freely programmable
Ambient temperature -5°C to 40°C
Humidity 5-95 % (non-condensing)
Dimensions (H x W x D) 140 mm x 140 mm x 30 mm
Weight 200 g
VdS approval with detect 3004
System approval S295054
Standards EN 54-2, 17
General remarks For the calculation of the loop structure it is necessary
to use the latest version of our loop-calculator
4. Accessories for Fire Control Panels detect 3004 and detect 3004 plus 13
2 Loop - interface, active, 2 x 140 mA for detect 3004 and detect 3004 plus
Art.-no. 32098 - Type DLI 3240P X1
2 Loop - interface, active, 2 x 140 mA, redundant for detect 3004 and detect 3004 plus
Art.-no. 32312 - Type DLI 3240P X1 - R
Description:
Microprocessor controlled loop interface for the
uninterruptible and short-circuit-proof use with the
loop3000 fire detection system components for the
connection of 2 x 126 fire detection system components
on two loops or 4 spurs
DLI 3240P X1 - R comes in redundant version with a
second processor for increased reliability in the loop
(redundancy)
Technical data
Properties:
Connection of loop3000 components in loop structure or spur-structure
2-wire-system-loop with up to 3.500 m loop length, (using wire lead JY(St)Y 2x2x0,8mm)
Easy and flexible installation and initialization via automatic and manual addressing
Integrated RS 232-interface for an easy analysis of the loop components,
the preadjustment of functions and commissioning of loop3000
8 integrated freely programmable open-collector-alarm outputs
2 integrated open-collector-alarm outputs for the programming of collecting functions
Supply via fire control panel detect 3004
Integrated short circuit isolaters on all loop outputs
Up to 42 T-branches per loop possible
Commissioning and service tool for analyzing and fault finding functions with "I-Check" software
Supply voltage 20-28 V DC via detect 3004 supply
Emergency supply via detect 3004 supply
No load current 40 mA
Quiescent current Depending on the loop structure-max. 210 mA
Alarm current Depending on the loop structure-max. 470 mA
Interface 1 x RS 232
Outputs 2 loops with each 140 mA / 3500 m for up to 126 loop3000 devices
per loop / alternatively 4 spurs
4 freely programmable monitored inputs
2 open collector outputs 30V DC / 90 mA for alarm and fault
8 open collector outputs 30 V DC / 90 mA freely programmable
Ambient temperature -5°C to 40°C
Humidity 5-95 % (non-condensing)
Dimensions (H x W x D) 140 mm x 140 mm x 30 mm
Weight 200 g
VdS approval with detect 3004
System approval S295054
Standards EN 54-2, 17
General remarks For the calculation of the loop structure it is necessary
to use the latest version of our loop-calculator
4. Accessories for Fire Control Panels detect 3004 and detect 3004 plus 14
Conventional-Interface, 8 detector zones for detect 3004 and detect 3004 plus
Art.-no. 30210 - Type CLI X1
Description:
Microprocessor controlled conventional interface for the
uninterruptible and short-circuit-proof use with
conventional detectors of the series CT 3000
Technical data
Properties:
Connection of up to 25 automatic conventional detectors of the series CT 3000
(10 manual call points) per detector zone
8 integrated freely programmable open-collector-alarm outputs
2 integrated open-collector-alarm outputs for the programming of collecting functions
Supply via fire control panel detect 3004
Supply voltage 20-28 V DC via detect 3004 supply
Emergency supply via detect 3004 supply
Quiescent current Approx. 50 mA
Alarm current Approx. 80 mA
Outputs 2 open collector outputs 30 V DC / 90 mA for alarm and fault
8 open collector outputs 30 V DC / 90 mA freely programmable
Ambient temperature -5°C to 40°C
Humidity 5-95 % (non-condensing)
Dimensions (H x W x D) 140 mm x 140 mm x 30 mm
Weight 200 g
VdS approval with detect 3004
System approval S295054
Standards EN 54-2, 17
General remarks Connection of conventional detectors of other manufacturers on request
Mounting plate for LED indicator module and printer for detect 3004 / detect 3004 plus
Art.-no. 30210 - Type CLI X1
Description:
Mounting plate for the installation into the front door of the
fire control panel detect 3004 in case of use of the LED
indicator modules and/or the printer
Technical data
Properties:
Suitable for all fire control panels of the series detect 3004
and for the remote display and control panel
Mounting of up to 6 pieces LED indicator modules ZM 8 possible
Provides facility for mounting of a built in printer PIP 2
Scope of supply including film and labelling strips
Colour Film RAL 7046 telegrey, plaque RAL 7035 light grey
Material Sheet steel
Dimensions (H x W) 228 mm x 365 mm
Weight Approx. 0,7 kg
System approval S295054
General remarks A subsequent mounting in the fire control panel is possible at any time
4. Accessories for Fire Control Panels detect 3004 and detect 3004 plus 15
LED indicator module, 8 detector zones for detect 3004 and detect 3004plus
Art.-no. 30088 - Type ZM 8
Description:
LED indicator module for the status indication of 8 detector
zones with yellow LEDs for fault and red LEDs for alarm
for the mounting into the front door of the fire control panel
detect 3004
Technical data
Properties:
Suitable for all fire control panels of series detect 3004
8 red LEDs for the indication of alarms of each detector zone
8 yellow LEDs for the indication of faults of each detector zone
Direct connection to the CPU via a 10 pole ribbon cable (included in delivery)
Possibilty for the labelling of each detector zone in the front of the panel,
by the integration in the front plate MP 3004 (not included in the basic version)
Up to 6 LED indicator modules can be connected in the front of the panel
2 modules can be connected directly to the CPU
For the modules 3-6 an adapter board will be necessary (Art-no. 30386)
Supply voltage 20-28 V DC via detect 3004 supply
Emergency power supply via detect 3004 supply
Quiescent current Approx. 2 mA
Alarm current Plus approx. 2 mA per LED-activation
Outputs 8 LED indicators red
8 LED indicators yellow
Ambient temperature -5 to 40°C
Humidity 5-95 % (non-condensing)
Dimensions (H x W x D) 80 mm x 43 mm x 12 mm
Weight Approx. 30g
VdS approval with detect 3004
System approval S295054
Standard EN 54-2, 17
plus
Extension Module for LED indicator 3 - 6 for detect 3004 and detect 3004
Art.-no. 30386 - Type ADB 48
Description:
Extension module for the connection of the 3rd up to the 6th
LED indictor module ZM 8 to the fire control panel of the
series detect 3004
Technical data
Properties:
Suitable for all fire control panels of series detect 3004
For the extension with LED indicator modules for 16 to 48 zones indication
Connection directly to the CPU maion board via 14 pole ribbon cable (incl. in the scope of delivery)
Supply voltage 20-28 V DC via detect 3004 supply
Emergency power supply via detect 3004 supply
Outputs 4 x 10 poles M
System approval S295054
4. Accessories for Fire Control Panels detect 3004 and detect 3004 plus 16
Indicator board for transmission unit interface for detect 3004 and detect 3004 plus
Art.-no. 30090 - Type TIB
Description:
Indicator board for the front door of the fire control panel
detect 3004 for the status indication of the transmission
unit interface
Technical data
Properties:
Suitable for all fire control panels of series detect 3004 and the Remote and Display Control Panel
3 LED-indicators red for alarm (main alarm, "fire brigade called", "call fire brigade")
1 LED- display yellow for the free switchable input of the UEI 3004plus ( key deposit box - alarm)
1 LED- display green for the free switchable input of the UEI 3004plus (key deposit box unlocked)
1 LED- display yellow for the status indication of the buttom for manual operation
(Transmission unit on-off)
1 LED- display yellow for the status indication of the buttom for manual operation (delay on/off)
Connection directly to the CPU via a 14 pole ribbon cable (included in delivery)
Supply voltage 20-28 V DC via detect 3004 supply
Emergency supply via detect 3004 supply
Alarm current Approx. 3 mA per LED-activation
Outputs 4 LED indicators red
1 LED indicators green
2 LED indicators yellow
Ambient temperature -5°C to 40°C
Humidity 5-95 % (non-condensing)
Dimensions (H x W x D) 145 mm x 50 mm x 14 mm
Weight Approx. 50g
VdS approval with detect 3004plus
System approval S295054
Standards EN 54-2
4. Accessories for Fire Control Panels detect 3004 and detect 3004 plus 17
Extinguishing control card, 1 extinguishing area for detect 3004 and detect 3004 plus
Art.-no. 30111 - Type ETB X1
Description:
Microprocessor controlled extinguishing control card for
the connection of an extinguishing area to the fire control
panel detect 3004 approved as extinguishing control
accord. to EN 12094
Technical data
Properties:
3 controllable monitored outputs for the control of the main- and area valve
and the re-flooding of the extinguishing area
Integrated additional signal device lines for the connection of signalling devices
in the extinguishing area (evacuation of the area)
2 lines for the activation of emergency stop and re-flooding function
4 low active-inputs for activation of the extinguishing mimic
via alarm outputs of the loop or conventional card
2 low active inputs for the advanced blockade of the extinguishing function
4 integrated relay contacts for pre-alarm, extinguishing activation, emergency stop
and re-flooding function
Adjustment possibilities of the pre alarm time of 0-60 sec via DIP - switch
Adjustment possibility for the fllooding time of 0-1270 sec via DIP - switch
Supply and use via internal bus of the fire control panel detect 3004
Supply voltage 21-29 V DC via detect 3004
Emergency supply via detect 3004 supply
Quiescent current Approx. 50 mA
Alarm current 60 mA + to 1 A per control line
Outputs 4 monitored control lines (max. 1 A)
4 relay contacts
Ambient temperature -5°C to 40°C
Humidity 5-95 % (non-condensing)
Dimensions (H x W x D) 140 mm x 140 mm x 20 mm
Weight Approx. 210g
VdS approval with EST 3004 G203068
System approval S295054
Standards EN12094-1
4. Accessories for Fire Control Panels detect 3004 and detect 3004 plus 18
Assembly frame 19" rack for detect 3004 and detect 3004 plus
Art.-no. 30161 - Type RMK 19
Description:
Assembly frame for the adaption of fire control panels of
the series detect 3004 to 19" racks
Technical data
Properties:
Suitable for all fire control panels of the series detect 3004 and the remote display and control panel
Delivery inluding mounting accessories
Colour RAL 7035 light grey
Material Sheet steel
Dimensions (H x W X D) 532,6 mm x 482,6 mm x 220 mm
Weight 5,25 kg
VdS approval with detect 3004
System approval S295054
Standards EN 54-2, 17
Technical data
Properties:
Door with 2 built in dummy boards
Built in door lock with simultaneous locking to the panels detect 3004
Colour RAL 7035 light grey
Material Sheet steel
Dimensions (H x W X D) 490 mm x 420 mm x 210 mm
Weight 7,4 kg
4. Accessories for Fire Control Panels detect 3004 and detect 3004 plus 19
Technical data
Properties:
Fire resistance and funtional integrity of more than 30 minutes accoding to F30,
tested according to DIN 4102 part 11 and 12
Smoke proof design with surface coating A2 - non combustible, protection class II
With cable cooling part EABK-2 and electromagnetic lock of the ventilation opening EBEL-EM
Housing for the on wall mounting with door stop left side
Removable door with locking option via turning lever
Angle of aperture of the door approx. 180°
Cable sealing for bundly entry (top, down, both sides)
Including mounting strap for wall mounting
Locking via driving plate with 2 point interlocking
Tridimensional adjustable entry systemfor all standard device mounting types
Integrated air cooling system via the backside and ventilation part
with locking activation and automatic triggering in case of fire
Locking activation at rise of temperature and electromagnetic activation
of the breather hole via smoke detectors
Highest mechanical strenght and chemical resistance
Integrated adjustable mounting system for the installation of the fire control panel detect 3004plus
Protection class IP 42
Colour housing RAL 7035 (Lightgrey)
DIN EN 4102 part 2
DIBT Z-86. 1-9
Further approvals (DIBT) Z-86. 1-7
Weight 116 kg
Inside dimension ( H x W x D) 750 x 500 x 340 mm
Outer dimensions ( H x W x D) 914 x 664 x 496 mm
Dimensions cable cooling part
EABK-2 (H x W x D) 500 x 620 x 195 mm
Weight EABK-2 25 kg
Rack units (heigth) 5 HE
Rack units (width) 2 BE
Space units 120 PE
5. Fire Control Panel detect 3016 and accessories 20
Fire Control Panel detect 3016, wall mounted housing, language kit English
Art.-no. 32422 - Type detect 3016 XL GB
Description:
Microprocessor controlled modular fire control panel for
the use with the loop3000 fire detection system
components approved according to EN 54 and VdS for the
use according to VdE 0833
Fire Control Panel detect 3016, wall mounted housing, language kit English
Art.-no. 32422 - Type detect 3016 XL GB
Fire Control Panel detect 3016, 19" front, English language kit
Art.-no. 32436 - Type detect 3016 19" GB
Technical data
Properties:
Integrated RS 232 - interface for the DPT programming software
and the connection of printers and other peripheral equipment
Integrated power supply 192 W according to EN 54 with
with 2 outputs for external devices rated at 24V DC/ 800mA
1 external output 24 V / 400 mA monitored for sounding/signalling devices
3 potential free relays for fire and fault
3 inputs for collective signals
Segmented front door allowing the quick assembly of LED indicator Modules and printers
Option for customised front logos
Possibility for complete system redundancy with redundant CPU and redundant loop interfaces
Up to 196 programmable detector zones
Additional up to 42 T-branches per loop possible
Event log memory of up to 500 messages
Programming of control logics and time dependent functions for the components of series loop3000
Customized customer texts allowing up to a maximum of 20 characters
Integrated alarm buffer and 2 detector/zone dependencies
Time controlled changeovers of sensitivity levels of loop3000 detectors by day/night modes
Software controlled disablements for zones and individual detectors via external inputs
Ability to change and edit inspection and reaction times along with all delays
Programming options for different alarm modes
Different access levels with password protection
Visual diagnostics and remote-control operations via the visualization software "Visual detect"
Commissioning and service tool for analyzing and fault finding functions with "I-Check" software
Incl. English language kit for control and programming
Supply voltage 230 V AC (-15%/+10%)
Power supply 24 V DC / 72 W / 3,5
1 output 24 V DC/800 mA for external devices
Emergency supply 2 x 12 V/ 45 Ah
Quiescent current Approx. 190 mA
Alarm current Approx. 250 mA
Interfaces 2 x RS 232; RS 4 and Bitbus as option for network
Display 4 alphanumeric lines LC-display, backlight
20 LED-display for status signal
Outputs 1 x 24 V /400 mA monitored for sounding/signalling devices
up to 16 loops 140 mA / 3500 m for up to 126 loop3000 elements each
3 relays outputs 250 V / 5 A for alarm and fault
8 open collector outputs 30 V DC / 90 mA
Inputs 3 inputs for collective signal
Ambient temperature -5°C up to +40°C
Humidity 5-95% (non-condensing)
Protection class IP30
Colour Light grey, RAL 7035
For more technical details please see next page.
5. Fire Control Panel detect 3016 and accessories 22
Fire Control Panel detect 3016, wall mounted housing, language kit English
Art.-no. 32422 - Type detect 3016 XL GB
Fire Control Panel detect 3016, 19" front, English language kit
Art.-no. 32436 - Type detect 3016 19" GB
Technical data
Material Sheet steel
VdS approval G203067
System approval S295054
Further approvals EN 12094
EN 12094 for 1 extinguishing systems
Standards EN 54-2:1997
EN 54-4: 1997
General remarks Scope of delivery without loop cards, network interfaces and batteries
Ground fault montoring via module EM (Art.-no. 30927)
Technical data
Properties:
Connection of up to 25 automatic conventional detectors of the series CT 3000
(10 manual call points) per detector zone
8 integrated freely programmable open-collector-alarm outputs
2 integrated open-collector-alarm outputs for the programming of collecting functions
Supply via fire control panel detect 3016
Supply voltage 20-28 V DC via detect 3016 supply
Emergency supply via detect 3016 supply
Quiescent current Approx. 50 mA
Alarm current Approx. 80 mA
Outputs 2 open collector outputs 30 V DC / 90 mA for alarm and fault
8 open collector outputs 30 V DC / 90 mA freely programmable
Ambient temperature -5°C to 40°C
Humidity 5-95 % (non-condensing)
Dimensions (H x W x D) 140 mm x 140 mm x 30 mm
Weight 200 g
VdS approval with detect 3016
System approval S295054
Standards EN 54 - 2, 17
General remarks Connection of conventional detectors of other manufacturers on request
5. Fire Control Panel detect 3016 and accessories 23
Technical data
Properties:
Connection of loop3000 components in loop structure or spur-structure
2 - wire - system - loop with up to 3.500 m loop length, (using wire lead JY(St)Y 2x2x0,8mm)
Easy and flexible installation and initialization via automatic and manual addressing
Integrated RS 232-interface for an easy analysis of the loop components,
the preadjustment of functions and commissioning of loop3000
8 integrated freely programmable open-collector-alarm outputs
2 integrated open-collector-alarm outputs for the programming of collecting functions
Supply via fire control panel detect 3016
Integrated short circuit isolaters on all loop outputs
Up to 42 T-branches per loop possible
Commissioning and service tool for analyzing and fault finding functions with "I-Check" software
Supply voltage 20-28 V DC via detect 3016 supply
Emergency supply via detect 3016 supply
No load current 40 mA
Quiescent current Depending on the loop structure-max. 210 mA
Alarm current Depending on the loop structure-max. 470 mA
Interface 1 x RS 232
Outputs 2 Loops 140 mA / 3500 m for up to 126 loop3000 devices
alternatively 4 spurs
4 freely programmable monitored inputs
2 open collector outputs 30V DC / 90 mA for alarm and fault
8 open collector outputs 30 V DC / 90 mA freely programmable
Ambient temperature -5°C to +40°C
Humidity 5-95 % (non-condensing)
Dimensions (H x W x D) 140 mm x 140 mm x 30 mm
Weight 200 g
VdS approval with detect 3016
System approval S295054
Standards EN 54-2, 17
General remarks For the calculation of the loop structure it is necessary
to use the latest version of our loop-calculator
5. Fire Control Panel detect 3016 and accessories 24
Mounting plate for LED indicator module and printer for detect 3016
Art.-no. 31947 - Type MP 3016
Description:
Mounting plate for the installation into the front door of the
fire control panel detect 3016 in case of use of the LED
indicator modules and/or the printer accord. to EN 54-2,17
Technical data
Properties:
Suitable for all fire control panels of the series detect 3016
Mounting of up to 6 pieces LED indicator modules ZM 32 possible
Provides facility for mounting of a built in printer PIP 2
Scope of supply including film and labelling strips; a subsequent mounting is possible at any time
Colour Film RAL 7046 telegrey, plaque RAL 7035 lightgrey
Material Sheet steel
Dimensions 400 mm x 483 mm
VdS approval with detect 3016
System approval S295054
5. Fire Control Panel detect 3016 and accessories 26
Technical data
Properties:
3 controllable monitored outputs for the control of the main- and area valve
and the re-flooding of the extinguishing area
Integrated additional signal device lines for the connection of signalling devices
in the extinguishing area (evacuation of the area)
2 lines for the activation of emergency stop and re-flooding function
4 low active-inputs for activation of the extinguishing mimic
via alarm outputs of the loop or conventional card
2 low active inputs for the advanced blockade of the extinguishing function
4 integrated relay contacts for pre-alarm, extinguishing activation, emergency stop
and re-flooding function
Adjustment possibilities of the pre alarm time of 0-60 sec via DIP-switch
Adjustment possibility for the fllooding time of 0-1270 sec via DIP-switch
Supply and use via internal bus of the fire control panel detect 3004
Supply voltage 21 - 29 V DC via detect 3016
Emergency supply via detect 3016 supply
Quiescent current Approx. 50 mA
Alarm current 60 mA + to 1 A per control line
Outputs 4 monitored control lines (max. 1 A)
4 relay contacts
Ambient temperature -5°C to 40°C
Humidity 5-95 % (non-condensing)
Dimensions (H x W x D) 140 mm x 140 mm x 20 mm
Weight Approx. 220g
VdS approval with EST 3016 G203067 and G207003
System approval S295054
Standards EN12094-1
5. Fire Control Panel detect 3016 and accessories 27
Technical data
Properties:
Fire resistance F30, tested according to DIN 4102 part 2
Functional integrity of more than 30 minutes, according to DIN 4102 part 11
Fire load insulation of more than 30 minutes, according to DIN 4102 part 11
Surface coating A2 - non combustible
Smoke proof
With cable cooling part EABK-3 and electromagnetic lock of the ventilation opening EBEL-EM
Housing for the on wall mounting
Door stop left side
Removable door for weight reduction
Locking option via turning lever
Angle of aperture of the door approx. 180°
Cable sealing for bundly entry (top, down, both sides)
Including mounting strap for wall mounting
Locking via driving plate with 2 point interlocking
Tridimensional adjustable entry system for all standard device mounting types
Integrated air cooling system with locking activation
Locking activation at rise of temperature
Electromagnetic activation of the breather hole via smoke detectors
High chemical resistance
High mechanical strenght and stability
Protection class IP 41
Colour housing RAL 7035 (Lightgrey)
DIN EN 4102 part 2
DIBT Z-86. 1-9
Further approvals (DIBT) Z-86. 1-7
Weight 169 kg
Inside dimension ( H x W x D) 900 x 750 x 340 mm
Outer dimensions ( H x W x D) 1024 x 874 x 434 mm
Dimensions cable cooling part
EABK-2 (H x W x D) 500 x 620 x 195 mm
Weight EABK-2 31 kg
Rack units (heigth) 6 HE
Rack units (width) 3 BE
Space units 216 PE
6. Accessories for Fire Control Panels detect 3004 and detect 3016 28
Technical data
Properties:
Possibility for 4 additional monitored and short-circuit-proof outputs
with max. 580 mA line current each
Connection of high and low resistant signalling devices via integrated pole switch
Outputs can be activated to be dependend on the buttom "ext. Warning on/off" of the fire control panel
7 inputs for the control of signal lines
Adjustment possibility for individual or collective control of all signal lines via jumper
24 V supply via supply unit of the fire control panel
Module -housing for the easy mounting onto a DIN rail
12 LED's for indication of operation and status
Cascading option of multiple modules of the same type
Operation voltage 21-37 V DC
Quiescent current 90 mA
Alarm current 500-2600 mA
Inputs 4 potentialfree
Outputs 4 x 580 mA monitored, short-circuit-proof,
switch for high and low resistant applications
Display 12 LEDs for operation and status signal
Ambient temperature -10°C to 50°C
Humidity 10-85% (non-condensing)
Colour Green
Material ABS
Dimensions (H x W x D) 125 mm x 130 mm x 70 mm
Weight Approx. 220 g
General remarks At use of low resistance signalling devices (alarm bells) consider
the correct wiring of the output lines
Please consider the dimensioning of the current supply
and emergency supply
6. Accessories for Fire Control Panels detect 3004 and detect 3016 29
Technical data
Properties:
Possibility for 8 additional monitored and seperately fused outputs with max. 400 mA each
8 additional parallel OC outputs (e.g. for the indication of status)
8 inputs for the parallel switch of the outputs of the control board
(possibility for the manual activation of the outputs)
Outputs can be activated to be dependend on the buttom "ext. Warning on/off" of the fire control panel
Adjustment possibility for individual or collective control of all signal lines
Central function for reset, lamp test etc.
24 V supply via supply unit of the fire control panel
Module-housing for the easy mounting onto a DIN rail
Cascading option of multiple modules of the same type
8 LEDs for indication of status
Operation voltage 21-28 V DC
Quiescent current 58 mA
Alarm current Quiescent current + current of each signal line
Inputs 16 potentialfree
Outputs 8 monitored outputs, seperately fused, 400 mA
Display 8 LEDs for status signal of the outputs
Ambient temperature -10°C to 50°C
Humidity 10-85% (non-condensing)
Colour Green
Material ABS
Dimensions (H x W x D) 125 mm x 175 mm x 60 mm
Weight Approx. 310 g
General remarks Please consider the dimensioning of the current supply
and emergency supply
6. Accessories for Fire Control Panels detect 3004 and detect 3016 30
Technical data
Properties:
Possibility for 8 additional change over contacts for the control of external circuits of up to 250 V / 5A
8 low-active inputs for the parallel switch of the outputs of the control board
1 input for the release or the switch off of the functions of the control board (e.g. at "FCP - door open")
Power supply 24V via power supply unit of the fire control panel
Module-housing for the easy mounting onto a DIN rail
8 LEDs for indication of status
Operation voltage 21-28 V DC
Quiescent current 5 mA
Alarm current 30-240 mA (30 mA per relay)
Inputs 8, low active
Outputs 8 change over contacts 250 V / 5 A
Display 8 LEDs for status signal of the outputs
Ambient temperature -10°C to 50°C
Humidity 10-85% (non- condensing)
Colour Green
Material ABS
Dimensions (H x W x D) 125 mm x 110 mm x 60 mm
Weight Approx. 300 g
General remarks Please consider the dimensioning of the current supply
and emergency supply
6. Accessories for Fire Control Panels detect 3004 and detect 3016 31
Technical data
Properties:
Extension for 32 programmable alarm output areas
Activation via internal I²C-bus or via RS232-Interface of the fire control panel
Remote mounting by connectors (via RS 232)
Power supply 24V via power supply unit of the fire control panel
Easy mounting via 32 pole pin contact bar in the connection board of the detect 3016,
via ribbon cable of the detect 3004 or the adapter plate (Art.-no. 30116)
Operation voltage 21-28 V DC
Quiescent current 3,5 mA
Alarm current 90 - 2880 mA (max. 90 mA per alarm output)
Inputs RS 232
Outputs 32 alarm zones
Ambient temperature -10°C to 50°C
Humidity 10-85% (non-condensing)
Colour Green
Dimensions (H x W x D) 140 mm x 140 mm x 25 mm
Weight Approx. 165 g
General remarks Please consider the dimensioning of the current supply
and emergency supply
Up to 24 outputs usable in the fire control panel detect 3004
Up to 3 AM-modules can be used in the fire control panel detect 3016
For remote mounting please use adapter module (Art.-no. 30116)
Mount in printer for the fire control panels detect 3004 / detect 3016
Art.-no. 30106 - Type PIP 2
Description:
Thermo-printer for the integration to the front plate of the
fire control panels detect 3004 and detect 3016
Technical data
Properties:
Direct connection to the RS 232 Interface of the fire control panel
8 kB of Integrated Buffer Memory
Thermoprint with fixed print heads
24 characters per line
58 mm paper width
Powered directly from the fire control panel
Operation voltage 21-28 V DC
Quiescent current 12 mA
Alarm Current 100 mA
Interface RS 232
Print ASCII Standard, international character set
Paper width 58 mm, Paper roll diameter 38 mm
Ambient temperature 0°C to 50 °C
Humidity 10-85 % (non-condensing)
Colour Black
Material ABS
Dimensions (H x W x D) 115 mm x 115 mm x 80 mm
Weight Approx. 310 g
General remarks Installation of this printer requires eithe mounting plate MP 3004 / 3016
The use of this printer in the detect 3004 reduces the battery capacity
to max. 18 Ah
Technical data
Properties:
Suitable for mount in printer PIP 2 and PIP 3004plus
Packing unit 5 rolls
Paper width 57mm
Outer diameter: 37mm
Inner diameter (bore) 12,3mm
6. Accessories for Fire Control Panels detect 3004 and detect 3016 33
Technical data
Properties:
Primary synchronized switching power supply with electronic overload functions
Integrated low voltage discharge protection
Controlled output voltage 24 V
Intelligent battery-management
LED - fault display and potential free fault outputs
Input voltage 230 V AC / 50 Hz
Output voltage 24 V
Output current 1,5 A according to operation mode
Output Fault relay 1A 50V
Battery capacity max. 2 x 12V / 3Ah (loading capacity up to 12 Ah)
Ambient temperature -5°C to +40°C
Humidity max rel 95 % (non-condensing)
Protection class IP 30
Colour Grey
Material ABS
Dimensions (H x W x D) 380 mm x 235 mm x 96 mm
Weight 1,5 kg without accumulators
CPD-Number 0786-CPD-20672
VdS approval G208156
6. Accessories for Fire Control Panels detect 3004 and detect 3016 34
Technical data
Properties:
Primary synchronized switching power supply with electronic overload functions
Integrated low voltage discharge protection
Controlled output voltage 27,6 V
Flexible input voltage range 110 to 230 V
Intelligent battery-management
LED - fault display and potential free fault outputs
Input voltage 110 V to 230 V AC / 50 Hz
Output voltage 27,6 V nominal
Output current 2 A for Primary 2 A synchronized mains adapter (Art.-no. 32579)
5 A for Primary 5 A synchronized mains adapter (Art.-no. 32580)
Battery capacity up to 2x 17 Ah
up to 2 x 38 Ah with separate housing for Art.-no. 32580
separate housing is available under Art.-no 32659 Type BATT-BOX
Ambient temperature -10°C to +40°C
Humidity 5-75% (non-condensing)
Protection class IP 20
Colour Grey
Dimensions (H x W x D) 420 mm x 400 mm x 80 mm
Weight 9 kg
Material Sheet steel
CPD-Number 0786-CPD-20787
VdS approval G209142
Accumulator 12 V / 7,2 Ah
Art.-no. 40056 - Type WP 7.2 - 12
Quick connector 4,8 or 6,4 mm
Internal resistance with 1KHz 22 mOhm
Maximum charging current 2,16 A
Capacity: 7,2 Ah
Dimensions (H x W x D): 94 mm x 151 mm x 65 mm
Weight: 2,45 kg
VdS approval: G109001
Accumulator 12 V / 12 Ah
Art.-no. 30155 - Type WP 12 - 12
Quick connector 4,8 or 6,4 mm
Internal resistance with 1KHz 13 mOhm
Maximum charging current 3,6 A
Capacity: 12 Ah
Dimensions (H x W x D): 100 mm x 151 mm x 9 mm
Weight: 4,27 kg
VdS approval: G103063
Accumulator 12 V / 18 Ah
Art.-no. 30156 - Type WP 18 - 12
Connectors for screws M5
Internal resistance with 1KHz 10 mOhm
Maximum charging current 5,4 A
Capacity: 18 Ah
Dimensions (H x W x D): 167 mm x 181 mm x 76 mm
Weight: 6,28 kg
VdS approval: G103064
Technical data
Properties:
Rechargeable accumulator for the emergency power supply for the fire control panels detect 3004 / 3016
Robust encapsulated housing
Maintenance-free
Battery charge condition after one month at 20°C 92%
Charging voltage 14,4 to 15 V
Output voltage 12 v DC
Ambient temperature -10°C to +40°C
Humidity 5-75% (non-condensing)
Protection class IP 20
Colour Grey
Material ABS
6. Accessories for Fire Control Panels detect 3004 and detect 3016 36
Accumulator 12 V / 26 Ah
Art.-no. 40001 - Type WP 26 - 12
Connectors for screws M5
Internal resistance with 1KHz 8 mOhm
Maximum charging current 7,8 A
Capacity: 26 Ah
Dimensions (H x W x D): 125 mm x 166 mm x 175 mm
Weight: 9,528 kg
VdS approval: G103065
Accumulator 12 V / 45 Ah
Art.-no. 30151 - Type WP 45 - 12
Connectors for screws M6,5
Internal resistance with 1KHz 6 mOhm
Maximum charging current 13,5 A
Capacity: 45 Ah
Dimensions (H x W x D): 171 mm x 198 mm x 166 mm
Weight: 14,79 kg
VdS approval: G105087
Accumulator 12 V / 65 Ah
Art.-no. 30461 - Type WP 65 - 12
Connectors for screws M6,5
Internal resistance with 1KHz 5 mOhm
Maximum charging current 19,5 A
Capacity: 65 Ah
Dimensions (H x W x D): 174 mm x 350 mm x 166 mm
Weight: 23,55 kg
VdS approval: G102001
Technical data
Properties:
Rechargeable accumulator for the emergency power supply for the fire control panels detect 3004 / 3016
Robust encapsulated housing
Maintenance-free
Battery charge condition after one month at 20°C 92%
Charging voltage 14,4 to 15 V
Output voltage 12 v DC
Ambient temperature -10°C to +40°C
Humidity 5-75% (non-condensing)
Protection class IP 20
Colour Grey
Material ABS
6. Accessories for Fire Control Panels detect 3004 and detect 3016 37
Conductor XT-base
Art.-no. 32495 - Type BXT BAS
Description:
Space saving universal base for overvoltage modules
without signal interruption for the placement of conductors
A secure earthing of the base is ensured via DIN rail
mounting
Technical data
Properties:
4-pole for all conductor modules suitable
Exchange of modules is possible without signal interruption
Maintenance free execution without integrated protective elements
Mounting and earthing via 35 mm DIN rail accord. to EN 60715
Connection via screw clamps up to 4mm² cable diameter
Ambient temperature -40°C to +80°C
Protection class IP 20
Colour Yellow
Material Polyamide PA 6.6
Dimensions (H x W x D) 90 mm x 12 mm x 43 mm
Weight 40 g
VdS approval G608001
System approval S295054 and S208123
Further approvals CSA, UL
6. Accessories for Fire Control Panels detect 3004 and detect 3016 38
Network-Interface, Bitbus
Art.-no. 30087 - Type CP BBI
Description:
Plug in module for a network integration of the fire control
panels detect 3004 and detect 3016 in a network of up to
64 participants
Technical data
Properties:
Plug in board for direct mounting into the fire control panels detect 3004 and detect 3016
Suitable for a direct connection of 2 network participants with a distance of up to 1.200 m
For up to 64 network participants in one network
Voltage supply via the fire control panel
Operation voltage 24 V DC
Current consumption Approx. 50 mA
Interface Bitbus-Interface
Ambient temperature -5°C to +40°C
Humidity 5-95% (non-condensing)
Dimensions (H x W x D) 49 mm x 59 mm x 20 mm
General remarks Plug in module for the fire control panel bitbus interface slot
The topology of the network has to be respected when commissioning (b
Technical data
Properties:
4-lines alphanumeric LC-Display with 10 mm character size with backlight
Integrated module for the connection to a network of fire control panels of series detect 3004 / 3016
Integrated scroll- and acoustics-function with control via control keys
Programming and data copying via fire control panel detect 3004 / 3016
Requires external voltage supply of 24 V
Including English language kit for control and programming
Aesthetically pleasing stainless steel housing with lockable front door
Operation voltage 24 V DC
Quiescent current Approx. 60 mA
Alarm current Approx. 75 mA
Interfaces RS 232; Integrated Bitbus Interface
Display 4-lines alphanumeric LC-Display, backlight
Ambient temperature -5°C to +40°C
Humidity 5-95% (non-condensing)
Protection class IP 30
Colour housing Light grey RAL 7035
Material Sheet steel
Dimensions (H x W x D) 240 mm x 295 mm x 43 mm
Weight Approx. 1,8 kg
7. Network components 40
Remote Display Control Panel, Master, small housing, English language kit
Art.-no. 32426 - Type ABF Master SC GB
Description:
Microprocessor controlled modular remote display control
panel for the control of a network of fire control panels of
the series detect 3004 and detect 3016
Remote Display Control Panel, Master or Slave, 19"-front, English language kit
Art.-no. 33333 - Type ABF Master or Slave SC GB
Description:
Remote Display Control Panel as Master or Slave in 19"
version. Please specify upon order.
Dimensions (H x W x D) 6 HE
Weight 19'' front plate approx. 1,9 kg
mounting plate RDCP-main board approx. 1,9 kg
For more technical details please see next page.
7. Network components 41
Remote Display Control Panel, Master, small housing, English language kit
Art.-no. 32426 - Type ABF Master SC GB
Remote Display Control Panel, Slave, small housing, English language kit
Art.-no. 32425 - Type ABF Slave SC GB
Remote Display Control Panel, Master or Slave, 19"-front, English language kit
Art.-no. 33333 - Type ABF Master or Slave SC GB
Technical data
Properties:
4 alphanumeric lines LC-display with backlight
Integrated display and control panel according to DIN EN 54
Integrated module for the connection to a network of fire control panels of the series detect 3004 / 3016
Integrated RS 232-Interface for an easy programming with the dpt-software
and the connection of printers and other peripheral equipment
External voltage supply 24 V required
1 external output 24 V / 400 mA monitored for sounding/signalling devices
3 potential free relays for fire and fault
3 inputs for collective signals
Integrated ground fault monitoring
Option for customised front logos
Event log memory of up to 1000 messages
Different access levels with password protection
Visual diagnostics and remote-control operations via the visulaization software "Visual detect"
including English language kit for control and programming
Operation voltage 24 V DC
Quiescent current 86 mA
Alarm current 146 mA
Interfaces RS 232
Integrated Bitbus-Interface
Display 4 alphanumeric lines LC-Display
Backlight
20 LED-display for status signals
Outputs 1x 24 V / 400 mA monitored for sounding/signalling devices
3 Relays outputs 250 V / 5A for alarm and fault
8 open collector outputs 30 V DC / 90 mA
Inputs 3 inputs for collective signal
Ambient temperature -5°C to +40°C
Humidity 5-95% (non-condensing)
Protection class IP 30
Colour Lightgrey RAL 7035
Material Sheet steel
Dimensions (H x W x D) 262 mm x 420 mm x 83 mm
Weight 6,0 kg
7. Network components 42
Network-PC-Interface, PCI-BITBUS
Art.-no. 32257 - Type IPC-BIT900-PCI
Description:
PC - plug in card for the integration of a PC as a BITBUS-
participant in the network of fire control panels of the
series detect 3004 and detect 3016
Network-PC-Interface, Ethernet-BITBUS
Art.-no. 32259 - Type ETH-BIT R
Description:
PC-Ethernet-module for the integration of a PC as a
BITBUS-participant in the network of fire control panels of
the series detect 3004 and detect 3016
Comes with Din rail housing for an easy mounting on a
DIN rail into the fire control panel
Technical data
Properties:
External 24 V supply via power supply of the fire control panel
Enables BITBUS use of up to 1.200 m distance between two nodes at a standard baud rate of 62,5kBit/s
Integrated DC-inverter for the isolation of the input voltage
Integrated load resistance for the slave function
32-Bit ARM7 with 2 MByte Flash and 512 kByte supported RAM
Isolated RS485-interface with substantial protective circuit for severe industrial conditions
BITBUS cable end with predefined potential
With LED for the transmission status (yellow) and for the operating status LED (green)
Operation voltage 12-30 V DC
Current consumption 100 mA
Interfaces RS 485 Master via Sub D 9 pole F and M
RS 485 Slave via Sub D 9 pole M
Ambient temperature -5°C to +40°C
Humidity 5-95% (non condensing)
Protection class IP 30
Dimensions (H x W x D) 64 mm x 151 mm x 48 mm
Weight Approx. 340 g
Max. length of network 13,2 km at baud rate of 62,5kBIT/s (10 repeater)
900 m at a baud rate of 375kBIT/s (3 repeater)
General remarks Connector for current supply included in the scope of delivery
The topology of the network has to be considered at comissioning
7. Network components 45
Technical data
Properties:
Enables external redundant 24V supply via 2. galvanically isolated supply
Enables BITBUS-operation with fibre optics multimode cable 62,5/125 µm or 50/125 µm
and ST-connectors
Robust industrial housing made of metall, suitable for the mounting on a DIN rail
6 LEDs for operating state, sending and receiving on both sides, fault
Isolated RS485-Interface with substantial protection circuitry for aggressive industrial ambient conditions
Enables BITBUS-operation with unlimited message length with Baudrates of 62,5kBit/s and 375kBit/s
Generation of a fault message via LED and an integrated alarm relays in case of failure
of the LWL-connection and disruption of the current supply
Operation voltage 18-32 V DC
Current consumption 500 mA
Interfaces RS 485 via Sub D 9 pole F or 4 pole field bus clamp
LWL Multimode 50/62,5µm via SC duplex or ST-connector
Fault output Change-over contact via 3 pole plug terminal
Humidity 5-95% (non-condensing)
Protection class IP 30
Dimensions (H x W x D) 115 mm x 36 mm x 107 mm
Weight Approx. 680 g
General remarks The topology of the network has to be considered at comissioning
7. Network components 46
Technical data
Properties:
Control module for the direct control of relay or OC - Output cards in the network
without the use of fire control panels detect 3004 / 3016
Easy connection of outputs cards via ribbon cable
Option for up to 8 Output cards per Output control board (Art.-no.30120 and Art.-no. 30122)
Up to 61 Output control boards in one network
Direct addressing in the network via fixed address
External voltage supply 24 V DC
Programming with special software and connection of a modem (Art.-no.30136)
Overall network programming of the outputs with mapping of corresponding subpanels
Integrated push button for manual reset-function
Red and green LED for the status display
Module-housing for the easy mounting onto a DIN rail
Operation voltage 21-28 V DC
Current consumption Approx. 140 mA
Interfaces Bitbus - Interface
RS 232
Ambient temperature -5°C to +40°C
Humidity 5-95% (non-condensing)
Protection class IP 20
Colour Green
Material ABS
Dimensions (H x W x D) 125 mm x 133 mm x 58 mm
Weight Approx. 300 g
General remarks Ribbon cable is included in the delivery of the output modules
Connection diagram of the control board is included at the
output modules
Interface RS 232
General remarks Scope of supply including power supply connection and interface cables
7. Network components 47
32 Open Collector Output card in a network for the use without a fire control panel detect 3004 / 3016
4 pole terminal block for the possibility of an output supply voltage of 5 or 8V, e.g. for LED-Displays
Quiescent current Approx. 30 mA
Alarm current Max. 90 mA per OC-output
Output 32 Open Collector 24 V DC / 90 mA
Weight Approx. 240 g
16 relays output card in a network for the use without a fire control panel detect 3004 / 3016
Quiescent current Approx. 20 mA
Alarm current Max. 90 mA per output
Output 16 relays, 1 change over contact 30 V DC / 2A
Weight Approx. 250 g
Technical data
Properties:
Control module for the direct activation of LEDs in a network
without use of the fire control panel detect 3004 / 3016
Consists of 2 modules with same dimesnions
Easy connection of up to 6 pieces of the 32 LED indicator module ZM32 (Art.-no. 30098)
via ribbon cable
Up to 61 participants (Control cards) connectable in a network
Direct addressing in the network by a fixed address
External voltage supply of 24 V DC required
Cross-network programming of the outputs with mapping to the subpanel
Integrated push button for a manual reset function
Red and green LED for the display of the operation status
Module -housing for an easy mounting onto a DIN rail
Operation voltage 21-28 V DC
Quiescent current 90 mA
Alarm-/operation current Max. 320 mA
Interfaces Bitbus-Interface
RS 232
Output ext. Load 6 x cable connection for CP ZM 32
3 Relays 30 V/2 A
Ambient temperature -5°C to +40°C
Humidity 5-95% (non-condensing)
Protection class IP 20
Colour Green
Material ABS
Dimensions (H x W x D) 2 pieces 125 mm x 133 mm x 58 mm
Weight Approx. 300 g per module
8. Software and tools 49
PC - connection cable
Art.-no. 32310 - Type UPC
Description: Length: 1,5 m
Universal connection cable for the programming of the fire Weight: Approx. 100 g
control panels of the series detect 3004 and detect 3016 Including adapter for both connection options
Technical data
Properties:
With nullmodem adapter suitable for the programming of the main board
A connection to the DLI-card with serial cable for the loop analysis
USB converter, 1m
Art.-no. 32326 - Type USB 2.0
Description: Length: 1,1 m
Converter module from serial interface to USB for the Weight: Approx. 100 g
programming of the fire control panels of the series Data rates of up to 1 MB per sec
detect 3004 and detect 3016 supprts USB 2.0 Standard
Technical data
Properties:
Simple connection of serial interfaces to an USB - Port
Suitable for Windows 98SE / 2000 /XP / Vista
Diagnostic and programming software for loop3000
Art.-no. 30501 - Type I-Check 3000
Description:
Software tool for the components of the loop3000 System
for an easy programming of the functions, analysation and
diagnostics in case of service and maintenance and for
installation and commissioning with graphic user interface
with display of the loop topology of the system
detect 3000 for the documentation
Technical data
Properties:
Windows-based software tool with graphic display of the loop topology
Comprehensive diagnostic function for support at commissioning and for
the localization of installation faults of existing systems
Analysis of the operating data of all loop3000 components for high service level of the system
via graphic display of actual data like pollution level, smoke concentration, temperature
Graphic display of the loop topology with actual addresses and serial numbers of the components
for the use for doumentation and plans
Integrated system access function for the modification and change of data also during operation
(e.g. change of sensitivities, change of mapping, change of module properties etc.)
Clearly arranged Windows user interface with print and export function (Word, Excel)
Scope of delivery CD with installation software
General remarks The programming with I-check software does not replace the
programming by the dpt-software
Suitable for Windows 98, 2000 and XP
8. Software and tools 50
Technical data
Properties:
Windows based softwaretool with upload and download function for the programming
of the functions of the fire control panels of the series detect 3004 / 3016 and the
network components of the system detect 3000 via a personal computer
Support of all functions of the programming of the system
Integrated option for the remote diagnostics via modem
Option for customer specific texts
Integrated time function for the time programming of different functions
for the fire control panels detect 3004 / 3016
Option for customer specific texts
Integrated time function for the time programming of different functions
for the fire control panels detect 3004 / 3016
Clearly arranged Windows user interface with print and export function (Word, Excel)
Scope of delivery CD with installation software
General remarks After each programming we recommend a function control
of the fire control panel
Suitable for Windows 98, 2000 and XP
8. Software and tools 51
Technical data
Properties:
Battery powered Stand-Alone tool with up and downloadfunction
for an easy manual adressing and programming of the loop3000 components
Support for diagnostics and programming functions for all detectors and modules
Easy assignment of customer specific detector data via integrated copy and paste function
Four line LC Display with backlight and adjustable brightness for a clear display of all values and data
16 buttom keypad for an easy use and clearly arranged input of data
Update option of the device software via integrated RS232-interface
Automatic switching off function at no use for higher battery lifetime
Acoustic alert at low battery
Scope of delivery 1 transportation suitcase, 3 batteries Type AA, 1 interface cable
1 connection cable for modules and manual call points
1 Easy check, 1 carrying strap
General remarks The programming of the automatic detectors can be done directly
via an integrated base for detector
Test- and programming tool Loop Tester
Art.-no. 31625 - Type LT 3000
Description:
Programming tool for an easy automatic or manual (Scan-
function) adressing and programming of the components
of the loop3000 via a PC.
Stand-Alone device with up- and downloadfunction for an easy automatic and manual (Scanfunction)
and programming of the components of the loop3000 via a personal computer without
the installation of a fire control panel
1 loop or 2 spurs suitable for connection for the complete test of the detectors/modules installation
or for the test of subareas (e.g. difficult to access areas)
including reset key for the reset of the loop tester to a defined basic status
Complete support of all diagnostic and programming functions for all detector and module data
Integrated RS 232-Interface for bidirectional data communication
Easy programming and diagnostic and input of customer specific data
via diganostic software I-Check 3000
Unlimited use of all features of the diagnostic software I-Check
including 230V-voltage supply for the diagnostic tool
Scope of delivery 1 suitcase, 1 voltage supply, 1 Interface cable
1 Loop-tester
General remarks The programming of the automatic detectors can be done directly
via an integrated base for detector
8. Software and tools 52
Technical data
Properties
Windowsbased software liscensed as basic version for one fire control panel and one PC
Windows-XP based network compatible software with Client/Server architecture
Various user levels with extensive user and policy management and an integrated simulation tool
Freely definable alarm management and procedure plans and integrated tool
for the automatic execution of procedure plans
Flexible with multilingual version and print-, export- and import function
Highest system security via data encryption and seperate installation and operation access levels
Extensive help functions integrated
Import of floor plans and programming data of the fire control panel via standard files
(dpt - files for programming data, dwg-files, wmf-files, jpg-files, bmp-files etc. for floor plans)
Easy, clearly arranged specific programming via flexible surfaces
Extensive logging of all events and messages with option for specific analysis
and print of floor plans (also for fire brigade route cards)
General remarks After each programming we recommend a function control
Suitable for Windows 98, 2000 and XP
Technical data
Properties:
Windows based software liscensed as basic version for one fire control panel and one PC
Windows-XP based network compatible software with Client/Server architecture
Modular structure of graphical software for the realization of different applications and extensions
Various user levels with extensive user and policy management and an integrated simulation tool
Freely definable alarm management and procedure plans and
integrated tool for the automatic execution of procedure plans
Flexible with multilingual version and print-, export- and import function
Highest system security via data encryption and seperate installation and operation access levels
Extensive help functions integrated
Import of floor plans and programming data of the fire control panel via standard files
(dpt - files for programming data; dwg-files, wmf-files, jpg-files, bmp-files etc. for floor plans)
Easy, clearly arranged specific programming via flexible surfaces
Extensive logging of all events and messages with option for specific analysis
and print of floor plans (also for fire brigade route cards)
Scope of supply CD with installation software, software liscence VD smart
for 1 fire control panel and 1 PC
Including liscense VD CE 1 for the operation of the fire control panel
USB Interface USB BIT ( Art.-no. 32258)
Liscence dongle
9. Addressable automatic detectors loop3000 54
Technical data
Properties:
Integrated measurement-system and algorithm for condensation recognition (Humitec ®)
Intelligent analysis and disruption mode for the elimination of false alarms (e.g. cigarette smoke)
Highest reliability by intelligent combination of thermal and optical sensor signals with via algorithms
Highest reliability by intelligent combination of thermal and optical sensor signals with via algorithms
Integrated temperature measurement as rate of rise procedure and maximum value
in accordance to EN54-5 1A
Detector sensitivities automatically calibrated and freely programmable
Fault monitoring of the measurement chamber signal and loop3000-electronics
Periodic sensor test
Automatic and manual addressing on the loop3000
Integrated Isolator and T-branch option
Alarm output for the triggering of a LED indicators
Functions completely integrated via loop3000 protocol
Disable and enable modes with individually adjustable sensitivities
Storage of last maintenance date
Self learning modes for the ambient conditions
Multicolour-LED for alarm (red) and fault (yellow)
Delivery including protective cover for installation phase
Operation voltage 15-30 V DC loop powered
Quiescent current 280 μA
Alarm current 5 mA
OC-outputs max. 10 mA for LED-indicator or piezo buzzer
Sensitivity 5 levels adjustable
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Air speed < 20 m/s
Protection class IP 40
Colour housing White (similar to RAL 9003)
Material ABS
Dimensions (H x Ø) 52 mm x 100 mm
CPD - Number 0786-CPD-20580
VdS approval G208095
System approval S295054, S208123 and S210001
Standards DIN EN 54–7, EN 54-5, CEA 4021, EN 54-17
9. Addressable automatic detectors loop3000 55
Technical data
Properties:
Integrated measurement-system and algorithm for condensation recognition (Humitec ®)
Intelligent analysis and disruption mode for the elimination of false alarms (e.g. cigarette smoke)
Highest reliability by intelligent combination of thermal and optical sensor signals with via algorithms
Highest reliability by intelligent combination of thermal and optical sensor signals with via algorithms
Integrated temperature measurement as rate of rise procedure and maximum value
in accordance to EN54-5 1A
Detector sensitivities automatically calibrated and freely programmable
Fault monitoring of the measurement chamber signal and loop3000-electronics
Periodic sensor test
Automatic and manual addressing on the loop3000
Integrated Isolator and T-branch option
Alarm output for the triggering of a LED indicators
Functions completely integrated via loop3000 protocol
Disable and enable modes with individually adjustable sensitivities
Storage of last maintenance date
Self learning modes for the ambient conditions
Multicolour-LED for alarm (red) and fault (yellow)
Delivery including protective cover for installation phase
Operation voltage 15-30 V DC loop powered
Quiescent current 280 μA
Alarm current 5 mA
OC-outputs max. 10 mA for LED-indicator or piezo buzzer
Sensitivity 5 levels adjustable
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Air speed < 20 m/s
Protection class IP 40
Colour housing White (similar to RAL 9003)
Material ABS
Dimensions (H x Ø) 52 mm x 100 mm
CPD - Number 0786-CPD-20580
VdS approval G208096
System approval S295054 and S208123
Standards DIN EN54–7, EN54-5, CEA4021, EN54-17
9. Addressable automatic detectors loop3000 56
Technical data
Properties:
Alarm evaluation with professional CO-sensor technology
Measurement of carbon monoxid with 2 alarm thresholds
Prealarm: 15 ppm in 15 min
Alarm: 30 ppm in 60 min
Integrated acoustic indication for CO-pre alarm and CO-alarm
Highest reliability by intelligent combination of thermal and CO sensor via algorithm
Integrated temperature measurement as rate of rise procedure and maximum value
in accordance to EN54-5
Periodic sensor test
Automatic and manual addressing on the loop3000
Integrated Isolator and T-branch option
Alarm output for the triggering of a LED indicators
Functions completely integrated via loop3000 protocol
Disable and enable modes with individually adjustable sensitivities
Multicolour-LED for alarm (red) and fault (yellow)
Delivery including protective cover for installation phase
CO-Sensor lifetime 5 years
Operation voltage 15-30 V DC loop powered
Quiescent current 600 μA
Alarm current 5 mA
OC-outputs max. 10 mA for LED-indicator or piezo buzzer
Sensitivity CO - Alarm at 30 ppm, heat accord. to EN 54 - 5 1A
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Air speed < 20 m/s
Protection class IP 40
Colour housing White (similar to RAL 9003)
Material ABS
Dimensions (H x Ø) 52 mm x 100 mm
CPD - Number 0786-CPD-20582
VdS approval G207005
System approval S295054 and S208123
Standards DIN EN54-5, EN54-17
General remark The Carbon Monoxide detector requires calibrating once a year
to ensure the high detection levels is maintained
9. Addressable automatic detectors loop3000 57
Technical data
Properties:
Highest reliability by intelligent combination of thermal and optical sensor signals with via algorithms
Exact pollution recognition by an additional independent measuring chamber
Integrated temperature measurement as rate of rise procedure and maximum value
in accordance to EN54-5 1A
Detector sensitivities automatically calibrated and freely programmable
Fault monitoring of the measurement chamber signal and loop3000-electronics
Periodic sensor test
Automatic and manual addressing on the loop3000
Article 30021 with integrated Isolator and T-branch option
Alarm output for the triggering of a LED indicators
Functions completely integrated via loop3000 protocol
Disable and enable modes with individually adjustable sensitivities
Storage of last maintenance date
Self learning modes for the ambient conditions
Multicolour-LED for alarm (red) and fault (yellow)
Delivery including protective cover for installation phase
Operation voltage 15-30 V DC loop powered
Quiescent current 280 μA
Alarm current 5 mA
OC-outputs max. 10 mA for LED-indicator or piezo buzzer
Sensitivity 5 levels adjustable
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Air speed < 20 m/s
Protection class IP 40
Colour housing White (similar to RAL 9003)
Material ABS
Dimensions (H x Ø) 52 mm x 100 mm
CPD - Number 0786-CPD-20197 (Art.-no. 30007 and 0786-CPD-20198 (Art.-no. 30021)
VdS approval G205052 (Art.-no. 30007) and G205051 (Art.-no 30021)
System approval S295054 and S208123
Standards DIN EN 54–7, EN 54-5, CEA 4021, EN 54-17
9. Addressable automatic detectors loop3000 58
Technical data
Properties:
Exact pollution recognition by an additional independent measuring chamber
Detector sensitivities automatically calibrated and freely programmable
Fault monitoring of the measurement chamber signal and loop3000-electronics
Periodic sensor test
Automatic and manual addressing on the loop3000
Article 30011 with integrated Isolator and T-branch option
Alarm output for the triggering of a LED indicators
Functions completely integrated via loop3000 protocol
Disable and enable modes with individually adjustable sensitivities
Storage of last maintenance date
Self learning modes for the ambient conditions
Multicolour-LED for alarm (red) and fault (yellow)
Delivery including protective cover for installation phase
Operation voltage 15-30 V DC loop powered
Quiescent current 280 μA
Alarm current 5 mA
OC-outputs max. 10 mA for LED-indicator or piezo buzzer
Sensitivity 5 levels adjustable
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Air speed < 20 m/s
Protection class IP 40
Colour housing White (similar to RAL 9003)
Material ABS
Dimensions (H x Ø) 44 mm x 100 mm
CPD - Number 0786-CPD-20035 (Art.-no. 30011) and 0786-CPD-20677 (Art.-no. 30009)
VdS approval G202002 (Art.-no. 30011) and G202003 (Art.-no. 30009)
System approval S295054 and S208123
Standards DIN EN54–7, EN54-17
9. Addressable automatic detectors loop3000 59
Technical data
Properties:
Suitable for environments with air streams of 20 m/s
Intelligent analysis for the elimination of false alarms
Highest reliability by intelligent smoke chamber sensor technology
Exact pollution recognition by an additional independent measuring chamber
Detector sensitivities automatically calibrated and freely programmable
Fault monitoring of the measurement chamber signal and loop3000-electronics
Periodic sensor test
Automatic and manual addressing on the loop3000
With integrated isolator and T-branch option
Alarm output for the triggering of a LED indicators
Functions completely integrated via loop3000 protocol
Disable and enable modes with individually adjustable sensitivities
Storage of last maintenance date
Self learning modes for the ambient conditions
Multicolour-LED for alarm (red) and fault (yellow)
Delivery including protective cover for installation phase
Operation voltage 15-30 V DC loop powered
Quiescent current 280 μA
Alarm current 5 mA
OC-outputs max. 10 mA for LED-indicator or piezo buzzer
Sensitivity 5 levels adjustable
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Air speed 20 m/s
Protection class IP 40
Colour housing White (similar to RAL 9003)
Material ABS
Dimensions (H x Ø) 44 mm x 100 mm
CPD - Number 0786-CPD-20036
VdS approval G202107
System approval S295054 and S208123
Standards DIN EN54–7
Heat detector with fixed and rate of rise temperature settings, without isolator
Art.-no. 30008 - Type PL 3200 T
Heat detector with fixed and rate of rise temperature settings, with isolator
Art.-no. 30010 - Type PL 3300 T
Description:
Heat detector with fixed and rate of rise temperature
settings for loop3000 with 1 thermal sensor for earliest fire
detection and indication in all environments with difficult
ambient conditions according to DIN EN54-5
(Art.-no.30010 with bidirectional Isolator according to DIN
EN54-17)
Technical data
Properties:
Integrated temperature measurement as rate of rise procedure
and maximum value in accordance to EN54-5 1A
Detector sensitivities automatically calibrated and freely programmable
Periodic sensor test
Automatic and manual addressing on the loop3000
Article 30010 with integrated Isolator and T-branch option
Alarm output for the triggering of a LED indicators
Functions completely integrated via loop3000 protocol
Disable and enable modes with individually adjustable sensitivities
Storage of last maintenance date
Multicolour-LED for alarm (red) and fault (yellow)
Delivery including protective cover for installation phase
Operation voltage 15-30 V DC loop powered
Quiescent current 280 μA
Alarm current 5 mA
OC-outputs max. 10 mA for LED-indicator or piezo buzzer
Sensitivity 5 levels adjustable
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Air speed < 20 m/s
Protection class IP 40
Colour housing White (similar to RAL 9003)
Material ABS
Dimensions (H x Ø) 44 mm x 100 mm
CPD - Number 0786-CPD-20043 (Art.-no. 30008) and 0786-CPD-20044 (Art.-no.30010)
VdS approval G203038 (Art.-no.30008) and G203037 (Art.-no.30010)
System approval S295054 and S208123
Standards DIN EN54-5
9. Addressable automatic detectors loop3000 61
Technical data
Dimensions (H x Ø) 42 mm x 95 mm
Material ABS, metal mesh
CPD - Number 0786-CPD-20037
VdS approval G205046
System approval S295054, S208123 and S210001
Standards DIN EN 54-7, EN 54-17
For more technical details please see page 64.
9. Addressable automatic detectors loop3000 62
Technical data
Dimensions (H x Ø) 47 mm x 110 mm
Material Glass, ABS
CPD - Number 0786-CPD-20041
VdS approval G204089
System approval S295054, S208123 and S210001
Standards DIN EN 54-7, EN 54-17
Technical data
Dimensions (H x W X D) 40 mm x 122 mm x 122 mm
Material Glass, ABS
Standards DIN EN 54-7, EN 54-17
For more technical details please see page 64.
9. Addressable automatic detectors loop3000 63
Technical data
Dimensions (H x Ø) 33 mm x 110 mm
Material ABS
Standards DIN EN 54-7, EN 54-17
Optical smoke detector, with isolator, with individual logo, round design, white
Art.-no. 32473 - Type PL 3308 O white
Description:
Optical smoke detector for loop3000 with 2 optical and 1
thermal sensor for earliest fire detection and indication and
with bidirectional isolator according to DIN EN 54-7/-17
Round design, with individual logo, white colour
Technical data
Dimensions (H x Ø) 55 mm x 113 mm
Material ABS
CPD - Number 0786-CPD-20575
VdS approval G208147
System approval S295054 and S208123
Standards DIN EN 54-7, EN 54-17
For more technical details please see page 64.
9. Addressable automatic detectors loop3000 64
Technical data
Properties:
Integrated connectors for LED indicator (Art.-no. 31193) or piezo buzzer (Art.-no. 32091)
Space for additional connectors Type WAGO 243
Integrated connectors for the connection of one spur for the loop extension (T-branch)
Mounting space for the piezo buzzer ( Art.-no. 32091) and the detector labelling clip (Art.-no. 30479)
Including transparent seal cover to protect the base against contaminents
Material ABS
Dimensions (H x Ø) 21 mm x 95 mm
10. Accessories for detectors 66
Technical data
Properties:
Integrated connectors for LED indicator (Art.-no. 31193) or piezo buzzer (Art.-no. 32091)
Space for additional connectors Type WAGO 243
Integrated connectors for LED indicator (Art.-no. 31193) or piezo buzzer (Art.-no. 32091)
Space for additional connectors Type WAGO 243
Integrated connectors for the connection of one spur for the loop extension (T-branch)
Mounting space for the piezo buzzer ( Art.-no. 32091) and the detector labelling clip (Art.-no. 30479)
Including transparent seal cover to protect the base against contaminents
Material ABS
Dimensions (H x Ø) 21 mm x 95 mm
10. Accessories for detectors 67
Piezo buzzer
Art.-no. 32091 - Type SP
Description:
Accoustic piezo alarm buzzer for direct connection to all
detectomat detector bases for the local accoustic
signalling in occupied areas (e.g hotels, residential homes
etc.)
Technical data
Properties
Direct voltage supply via detector/ loop
Activation by parallel connection to the alarm LED of the detector
Local accoustic alarm
Loud accoustic signal due to external and free sound emission
Mechanically compatible to all detectomat standard detector bases
Volume Approx. 85 dB / 0.3 m
Colour housing White (similar RAL 9003)
Material ABS
Dimensions (H x W x D) 8 mm x 45 mm x 35 mm
Technical data
Properties
Plugs directly onto the detector base
Maximum character height of 25 mm
Pack contains 30 units
Volume Approx. 85 dB / 0.3 m
Colour housing White (similar RAL 9003)
Material ABS
Technical data
Properties
Integrated temperature-controlled heater for regulated ambient conditions for detectors.
Including Detector base SDB 3000
Integrated connectors for LED indicator (Art-no. 31193) or piezo buzzer (Art-no. 32091)
Space for additional connectors Type WAGO 243
Integrated connectors for the connection of one spur for the loop extension (T-branch)
Operation voltage 24 V DC
Current consumption 160 mA
Power max. 4 W
Ambient temperature -30°C to + 60°C
Protection class IP 66
Colour housing White
Dimensions (H x Ø) 335 g
Technical data
Properties
Integrated sealing against condensate and dripping water
2 cable entry points for cable glands M16
Without detector base
Colour housing White (similar RAL 9003)
Material ABS
Dimensions (H x Ø) 43,5 mm x 105 mm
Protection class IP 66
Weight 40 g
10. Accessories for detectors 70
Technical data
Properties
Housing without detector base
Including entry and exit pipe, pipe lenght 210mm
Suitable for air ducts up to a size of 1500 mm
Air speed up to 25 m/s
Air duct size from 300 mm up to 1500 mm
Protection class IP 64
Colour housing Grey
Material ABS
Dimensions (H x W x D) 200 mm x 110 mm x 92 mm
General remarks Special lenghts for entry pipes available on request
Parallel Indicator
Art.-no. 31193 - Type PA
Description:
Intelligent detector parallel indicator for the external optical
indication of the installation place of one or more detectors
Technical data
Properties
White wall mounting housing, red colour
Aestethical robust wall mounted housing according with IP 30
Operation voltage 24 V DC
Alarm current 4 mA
Ambient temperature -10°C to +50°C
Weight Approx. 65 g
Material ABS
Dimensions (H x W x D) 84 mm x 84 mm x 35 mm
CPD-Number 0786-CPD-20765
VdS approval G294052
System approval S295054, S208123 and S210001
10. Accessories for detectors 71
Technical data
Properties
Protection of the detector against foreign objects like e.g. balls or other objects with a solid metal grid
Compatible to detectors of the design variants 0, 1 and 2
Installation of the protection cage after the detector installation
with three fixation points (screw fixation)
Cable entry from the back required for the detector base
Colour White
Material Steel
Dimensions (H x Ø) 75 mm x 150 mm
Weight Approx. 150 g
Technical data
Properties
Protection of the detector, siren or beacon against foreign objects
like e.g. balls or other objects with a solid metal grid
Installation of the protection cage after the device installation (screw fixation)
Cable entry from the back required for the detector base, siren and beacon
Colour White
Material Steel
Dimensions (H x Ø) 160 mm x 120 mm
Weight Approx. 140 g
10. Accessories for detectors 72
Technical data
Properties:
Steplessly variable from 270 to 480 mm
Angle of the detector bracket stepless adjustable from 0° to 110°
Rear cable entry in the detector possible
Colour RAL 7035 light grey
Material Sheet steel powder coated
Dimensions (H x W x D) 135 mm x 100 mm x 270 mm to 480 mm
Weight 1.200 g
Technical data
Properties:
Distance to the wall: 400 mm
Rear cable entry in the detector possible
Colour RAL 7035 light grey
Material Sheet steel powder coated
Dimensions (H x W x D) 50 mm x 100 mm x 400 mm
Weight 770 g
Technical data
Properties:
Distance to the wall: 200 mm
Rear cable entry in the detector possible
Colour RAL 7035 light grey
Material Sheet steel powder coated
Dimensions (H x W x D) 50 mm x 100 mm x 200 mm
Weight 390 g
11. Addressable manual call points 74
Technical data
Properties
Manual Call Point mechanics for the activation of a manual alarm
Non-destructive activation and reset via mechanics
Automatic and manual addressing on the loop3000
Integrated isolator
Functions completely integrated via loop3000 protocol
Integrated red alarm-LED
Operation voltage 15 to 30 V DC loop powered
Quiescent current 280 μA
Alarm current 5 mA
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Protection class IP 32
Colour housing Red (RAL 3000)
Material ABS
Dimensions (H x W x D) 89 mm x 89 mm x 51 mm
CPD-Number 0333-CPD-075280
11. Addressable manual call points 75
Technical data
Properties
Push Button mechanics for the activation of a manual alarm
Activation after smash of the front glass and button push
Integrated reset mechanics
Automatic and manual addressing on the loop3000
Integrated Isolator and T-branch option
Potentialfree alarm output for the activation of e.g. a parallalel indicator
Functions completely integrated via loop3000 protocol
Integrated red alarm-LED
Operation voltage 15 to 30 V DC loop powered
Quiescent current 280 μA
Alarm current 280 μA ; 5 mA when alarm-LED is active
OC-outputs max. 10 mA for parallel indicator
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Protection class IP 42
Colour housing Red (RAL 3000)
Material ABS
Dimensions (H x W x D) 135 mm x 135 mm x 33 mm
Colour housing Red (RAL 3000)
CPD-Number 0786-CPD-20382
VdS approval G203021
System approval S295054 and S208123
Standards DIN EN 54-11, EN54-17
Accessories Spare glass (Art.-no. 31910)
Spare key metal (Art.-no. 40054)
General remarks Suitable for the fitting into extinguishing cabinets
Spare key
Art.-no. 40054 - Type HFM SCH M
11. Addressable manual call points 76
Technical data
Properties
Push Button mechanics for the activation of a manual alarm
Activation after smash of the front glass and button push
Integrated reset mechanics
Automatic and manual addressing on the loop3000
Integrated Isolator and T-branch option
Potentialfree alarm output for the activation of e.g. a parallalel indicator
Functions completely integrated via loop3000 protocol
Integrated red alarm-LED
Operation voltage 15 to 30 V DC loop powered
Quiescent current 280 μA
Alarm current 280 μA ; 5 mA when alarm-LED is active
OC-outputs max. 10 mA for parallel indicator
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Protection class IP 42
Colour housing Red (RAL 3000)
Material Aluminium
Dimensions (H x W x D) 125 mm x 125 mm x 34 mm
Colour housing Red (RAL 3000)
CPD-Number 0786-CPD-20382
VdS approval G203021
System approval S295054 and S208123
Standards DIN EN 54-11, EN54-17
Accessories Spare glass (Art.-no. 31910)
Spare key metal (Art.-no. 40054)
Wheatherproof housing (Art.-no. 31091)
General remarks Suitable for a wheatherproof housing
Technical data
Properties
Robust aluminium protective housing
Including seal and gasket set for the mounting of the housing
Sealing and gasket set for a protected cable entry
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Protection class IP 54
Weight Approx. 295 g
Colour housing Red (RAL 3000)
Material Aluminium
Dimensions (H x W x DT) 145 mm x 131 mm x 55 mm
Spare key
Art.-no. 40054 - Type HFM SCH M
Technical data
Properties
Key for opening of all manual call points fo the series PL and CT
Die-casting design, metal
12. Addressable I/O-elements loop3000 78
Technical data
Properties:
Connecting module with one freely programmable Input and one freely programmable output
Programming of different switching variants of input and output also with time control
Monitoring of the operating status via loop3000
Independent programming of Input and Output
Automatic and manual addressing on the loop3000
Integrated Isolator and T-branch option
Functions completely integrated via loop3000 protocol
Multicolour-LED for alarm (red) and fault (yellow)
Aestethical robust wall mounted housing according with IP 54
Operation voltage 15 to 30 V DC loop powered
Quiescent current 460 μA
Alarm current 460 µA ; 5 mA if alarm-LED is active
Output Relay 1 change over contact 30 V DC / 1A
Input Low active monitored
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Weight Approx. 185 g
Protection class IP 54
Colour housing Grey (similar to RAL 7035)
Material ABS
Dimensions (H x W x D) 93 mm x 93 mm x 55 mm
CPD-number 0786-CPD-20459
VdS approval G205029
System approval S295054, S208123 and S210001
Standards DIN EN 54-18, 17
12. Addressable I/O-elements loop3000 79
Technical data
Properties:
Integrated automatic switch function of the output
at "external signal line on/off" signal by the fire control panel
Connecting module with one freely programmable fault input and
one output for the connection of signalling devices
Monitoring of the operating status via loop3000
Independent programming of Input and Output
Automatic and manual addressing on the loop3000
Integrated Isolator and T-branch option
Functions completely integrated via loop3000 protocol
Multicolour-LED for alarm (red) and fault (yellow)
Programming of different switching variants of input and output also with time control
Aestethical robust wall mounted housing according with IP 54
Operation voltage 15 to 30 V DC loop powered
Current consumption 460 μA
Input Relay 1 change over contact 30 V DC / 1A
Output Low active monitored
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Weight Approx. 190 g
Protection class IP 54
Colour housing Grey (similar to RAL 7035)
Material ABS
Dimensions (H x W x D) 93 mm x 93 mm x 55 mm
CPD-number 0786-CPD-20460
VdS approval G205030
System approval S295054, S208123 and S210001
Standards DIN EN 54-18, 17
General remarks The fault input can be used for the monitoring module UBW 3311
Accessories Possibility for monitoring of the output with UBW 3311 (Art.-no. 32073)
12. Addressable I/O-elements loop3000 80
Monitoring module single Output, for IOM 3311 and OMS 3301
Art.-no. 32073 - Type UBW 3311
Description:
Monitoring module for the use in the modules IOM 3311
and OMS 3301 for the monitored triggering of external
optical and acoustic signalling devices
Add-on module for the direct mounting into the housing of
the modules OMS 3301 and IOM 3311
Technical data
Properties:
Module for the monitoring of one output line with 24V and up to 1A for broken wire and short circuit
Polarity switchover at activation of the output
Integrated fault output for the connection to the monitored input of the modules IOM and OMS
External voltage supply of 24V
Circuit board for the integration in the module housings IOM 3311 and OMS 3301
Operation voltage 24V
Quiescent current 11 mA
Alarm current 11 mA
Output 24 V / 1 A monitored
Relays-fault output
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Weight Approx. 50 g
Protection class None
Dimensions (H x W x D) 20 mm x 38 mm x 35 mm
12. Addressable I/O-elements loop3000 81
Technical data
Properties:
Connecting module with one freely programmable Input and one freely programmable output
Additional parallel alarm output (blinking) for the control of a status indicator (without series resistor)
Programming of different switching variants of input and output also with time control
Monitoring of the operating status via loop3000
Independent programming of Input and Output
Automatic and manual addressing on the loop3000
Integrated Isolator
Functions completely integrated via loop3000 protocol
Completely encapsulated module for the integration
in special applications with control by the loop3000
Operation voltage 15 to 30 V DC loop powered
Quiescent current 380 μA
Alarm current 380 µA ; 5 mA if alarm-LED is active
Output 1 Open Collector 500 mA
1 10 mA parallel for LED-status indication
Input low active monitored
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Weight Approx. 20 g
Protection class IP 30
Colour housing Blue
Material ABS
Dimensions (H x W x D) 27 mm x 73 mm x 15 mm
CPD-number 0786-CPD-20530
VdS approval G205047
System approval S295054, S208123 and S210001
Standards DIN EN 54-18, 17
12. Addressable I/O-elements loop3000 82
Technical data
Properties:
Integrated automatic switch function of the output at
"external signal line on/off" signal by the fire control panel
Connecting module with one freely programmable fault input and
one output for the connection of signalling devices
Programming of different switching variants of input and output also with time control
Monitoring of the operating status via loop3000
Independent programming of Input and Output
Automatic and manual addressing on the loop3000
Integrated Isolator
Functions completely integrated via loop3000 protocol
Completely encapsulated module for the integration
in special applications with control by the loop3000
Operation voltage 15 to 30 V DC loop powered
Current consumption 380 μA
Output 1 Open Collector 500 mA
1 10 mA parallel for LED-status indication
Input Low active monitored
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Weight Approx. 20 g
Protection class IP 30
Colour housing Blue
Material ABS
Dimensions (H x W x D) 27 mm x 73 mm x 15 mm
CPD-number 0786-CPD-20530
VdS approval G205047
System approval S295054, S208123 and S210001
Standards DIN EN 54-18, 17
12. Addressable I/O-elements loop3000 83
Technical data
Properties:
Voltage selection for the detector zone supply via "jumper" on the module board.
External supply of conventional detector zones for the flexible use of
different conventional detectors with different current consumptions and operation voltages
Possibility for parametrization of short-circuit, wire break, prealarm and alarm thresholds
Automatic and manual addressing on the loop3000
Integrated Isolator and T-branch option
Functions completely integrated via loop3000 protocol
Multicolour-LED for alarm (red) and fault (yellow)
Aestethical robust wall mounted housing according with IP 54
Operation voltage 15 to 30 V DC loop powered
External supply output 12V or 24 V DC
Quiescent current 560 μA
Alarm current 560 µA; 5 mA if alarm-LED is active
Input 1 monitored detector zone with up to 65 mA
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Weight Approx. 190 g
Protection class IP 54
Colour housing Grey (similar to RAL 7035)
Material ABS
Dimensions (H x W x D) 93 mm x 93 mm x 55 mm
CPD-number 0786-CPD-20373
VdS approval G206048
System approval S295054 and S208123
Standards DIN EN 54-18, 17
13. Addressable signalling devices loop3000 84
Technical data
Properties:
Activation, monitoring and supply via loop3000 protocol
Integrated automatic reset function at signal "external signal line on/off" by the fire control panel
Monitoring of the operating status via loop3000
Independent programming via autarkic loop address
Automatic and manual addressing on the loop3000
Integrated isolator
4 different tones adjustable via DIP - switch (including DIN tone)
Integrated dual tone alarm function via seperate activation possible
Volume control via integrated potentiometer
Functions completely integrated via loop3000 protocol
Aestethical robust wall mounted housing according with IP 54
Operation voltage 15 to 30 V DC loop powered
Quiescent current 280 μA
Alarm current 5 mA
Volume max. 97 dB
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Weight 340 g
Protection class IP 54
Colour housing Red (Art.-no. 31836) or white (Art.-no 32012)
Material ABS
Dimensions (H x Ø) 100 mm x 101 mm
CPD-number 0786-CPD-20452
VdS approval G208103
System approval S295054, S208123 and S210001
Standards DIN EN 54–3, 17
General remarks For the calculation/design of the number of loop3000-signalling devices
please use the latest loop-calculator version
13. Addressable signalling devices loop3000 85
Accessories:
Art.-no. 32067: Cover for loop3000-Base-Sounder, red,
Type AD R
Art.-no. 32068: Cover for loop3000-Base-Sounder, white,
Type AD W
Art.-no. 32472: Cover for loop3000-Base-Sounder, white,
Type AD Ring
Technical data
Properties:
Activation, monitoring and supply via loop3000 protocol
Integrated automatic reset function at signal "external signal line on/off" by the fire control panel
Monitoring of the operating status via loop3000
Independent programming via autarkic loop address
Automatic and manual addressing on the loop3000
Integrated isolator
32 different tones adjustable via DIP-switch (including DIN tone)
Integrated dual tone alarm function via seperate activation possible
Functions completely integrated via loop3000 protocol
Cover plate in red or white colour
Operation voltage 15 to 30 V DC loop powered
Quiescent current 400 μA
Alarm current 6 mA
Volume max. 85 dB
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Weight 250 g
Protection class IP 54
Colour housing Base sounder in white, covers in red or in white
Material ABS
Dimensions (H x Ø) 27 mm x 117 mm
CPD-number 0786-CPD-20525
VdS approval G208144
System approval S295054, S208123 and S210001
Standards DIN EN 54-3, 17
General remarks For the calculation/design of the number of loop3000-signalling devices
please use the latest loop-calculator version
13. Addressable signalling devices loop3000 86
Technical data
Properties:
Activation, monitoring and supply via loop3000 protocol
Integrated automatic reset function at signal "external signal line on/off" by the fire control panel
Monitoring of the operating status via loop3000
Independent programming via autarkic loop address
Automatic and manual addressing on the loop3000
Integrated Isolator and T-branch option
32 different tones via DIP-switch, including DIN-Tone
Integrated dual tone alarm function via seperate activation possible
Functions completely integrated via loop3000 protocol
Aestethical robust wall mounted housing according with IP 54
Operation voltage 15 to 30 V DC
Quiescent current 280 μA
Alarm current 1,28 mA ; via external supply: 9 to 29 mA
Volume max. 111 dB
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Weight 340 g
Protection class IP 54
Colour housing Red (Art.-no. 30204) or white (Art.-no 30527)
Material ABS
Dimensions (H x Ø) 93 mm x 93 mm
Standards DIN EN 54-3, 17
General remarks For the calculation/design of the number of loop3000-signalling devices
please use the latest loop-calculator version
13. Addressable signalling devices loop3000 87
Technical data
Properties:
Activation, monitoring and supply via loop3000 protocol
Integrated automatic reset function at signal "external signal line on/off" by the fire control panel
Monitoring of the operating status via loop3000
Independent programming via autarkic loop address
Automatic and manual addressing on the loop3000
Integrated short circuit isolator
Integrated 1 Hz LED-beacon
Functions completely integrated via loop3000 protocol
Aestethical robust wall mounted housing according with IP 43
Operation voltage 15 to 30 V DC loop powered
Quiescent current 400 μA
Alarm current 6 mA
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Weight 145 g
Protection class IP 43
Colour housing White housing, red cover (Art.-no. 32058); orange cover (Art.-no 32090)
Material ABS
Dimensions (H x Ø) 80 mm x 98 mm
General remarks For the calculation/design of the number of loop3000-signalling devices
please use the latest loop-calculator version
13. Addressable signalling devices loop3000 88
Technical data
Properties:
Activation, monitoring and supply via loop3000 protocol
Monitoring of the operating status via loop3000
Independent programming via autarkic loop address
Automatic and manual addressing on the loop3000
Integrated Isolator
Functions completely integrated via loop3000 protocol
Aestethical robust wall mounted housing according with IP 30
Operation voltage 15 to 30 V DC
Quiescent current 400 μA
Alarm current 6 mA
Ambient temperature -10°C to +50°C
Humidity max. 93 % (+/-2%)
Weight 65 g
Protection class IP 30
Colour housing White housing, red calotte
Material ABS
Dimensions (H x W x D) 84 mm x 84 mm x 35 mm
CPD-number 0786-CPD-20535
VdS approval G208141
System approval S295054, S208123 and S210001
Standards EN 54-17
General remarks The parallel indicator Art.-no. 31193 can be connected directly to
the integrated OC-output of the detector for a direct display of the
detector status.
For the calculation/design of the number of loop3000-signalling devices
please use the latest loop-calculator version
14. Conventional signalling devices 89
Technical data
Properties:
32 different tones (incl. DIN tone) adjustable via DIP button
Wide band signal from 440 to 2900 Hz
Volume and alarm current adjustable via integrated DIP-button
Flat design
Operation voltage 12-35 V
Alarm current from 6 mA to 36
Volume max 99 dB
Ambient temperature -20°C to +70°C
Weight 220 g
Protection class IP 43
Colour housing Red (Art.-no. 32051) or white (Art.-no 32053)
Material ABS
Dimensions (H x Ø) 65 mm x 94 mm
CPD-number 0832-CPD-0255
VdS approval G 205137
Standards DIN EN 54-3
General remarks IP 65 model available upon request
14. Conventional signalling devices 90
Technical data
Properties:
32 different tones (incl. DIN tone) adjustable via DIP button
Automatic synchronisation
Integrated two tone alarm function
Flat design
Operation voltage 9 - 28 V
Alarm current 15 mA at DIN tone
Volume max 100 dB, 94 dB at DIN tone
Ambient temperature -10°C to +55°C
Weight 240 g
Protection class IP 21C
Colour housing Red (Art.-no. 31689) or white (Art.-no 31690)
Material ABS FR
Dimensions (H x Ø) 63 mm x 63 mm
CPD-number 0832-CPD-0523
VdS approval G209123
System approval S295054, S210001
Standards DIN EN 54-3
14. Conventional signalling devices 91
Technical data
Properties:
32 different tones (incl. DIN tone) adjustable via DIP button
Automatic synchronisation
Volume internally adjustable
Integrated two tone alarm function
Flat design
Operation voltage 9 - 28 V
Alarm current 3 to 33 mA
Volume 64 to 111 dB, 99 dB at DIN tone
Ambient temperature -25°C to +70°C
Weight 250 g
Protection class IP 54
Colour housing Red (Art.-no. 31838) or white (Art.-no 30198)
Material ABS FR
Dimensions (H x Ø) 63 mm x 93 mm
CPD-number 0832-CPD-0128
VdS approval G206019
System approval S295054, S210001
Standards DIN EN 54-3
Accessories
Flush-mounted base for IP65, red
Art.-no. 40059 - Type UB r
Flush-mounted base 48mm for IP65, red
Art.-no. 31468 - Type PG DG r
Flush-mounted base for IP65, white
Art.-no. 40060 - Type UB w
Flush-mounted base 48mm for IP65, white
Art.-no. 31467 - Type PG DG w
14. Conventional signalling devices 92
Properties:
32 different tones (incl. DIN tone) adjustable via DIP button
Automatic synchronisation
Volume internally adjustable
Integrated two tone alarm function
Flat design
Operation voltage 9 - 28 V
Alarm current 190 to 260 mA, 240 mA at DIN tone
Volume 88 to 120 dB, 112 dB at DIN tone
Ambient temperature -25°C to +55°C
Weight 210 g
Protection class IP 42
Colour housing Red
Material ABS FR
Dimensions (H x Ø) 96 mm x 108 mm x 108 mm
VdS approval G206027
System approval S295054, S210001
Standards DIN EN 54-3
General remarks IP 65 model available upon request
14. Conventional signalling devices 93
Base-Sounder
Art.-no. 32055 - Type Verso 32
Description:
Acoustic multiple tone sounder for an external accoustic
alarm accord. to DIN EN 54-3
Base design
Accessories:
Art.-no. 32067: Cover for loop3000-Base-Sounder, red,
Type AD R
Art.-no. 32068: Cover for loop3000-Base-Sounder, white,
Type AD W
Art.-no. 32472: Cover for loop3000-Base-Sounder, white,
Type AD Ring
Technical data
Properties:
32 different tones (incl. DIN tone) adjustable via DIP button
Wide band signal from 440 to 2900 Hz
Volume and alarm current adjustable via integrated DIP - button
Flat design
Cover plate in red or white colour
Operation voltage 15 to 30 V DC loop powered
Quiescent current 400 μA
Alarm current 6 mA
Volume max. 85 dB
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Weight 250 g
Protection class IP 54
Colour housing Base sounder in white, covers in red or in white
Material ABS
Dimensions (H x Ø) 27 mm x 117 mm
CPD-number 0786-CPD-20525
VdS approval G208144
System approval S295054, S208123 and S210001
Standards DIN EN 54–3, 17
General remarks For the calculation/design of the number of loop3000-signalling devices
please use the latest loop-calculator version
14. Conventional signalling devices 94
Base sounder
Art.-Nr. 30214 - Type SQ 32 W
Description:
Acoustic multiple tone sounder for the external acoustic
alarm accord. to DIN EN 54-3
Properties:
32 different tones (incl. DIN tone) adjustable via DIP button
Automatic synchronisation
Flat design
Operation voltage 10 - 28 V DC
Alarm current 8 to 35 mA, 16 mA at DIN tone
Volume 67 to 102 dB, 91 dB at DIN tone
Ambient temperature -10°C to +55°C
Weight 210 g
Protection class IP 21C
Colour housing White
Material ABS FR
Dimensions (H x Ø) 28 mm x 113 mm
VdS approval G206022
System approval S295054, S208123 and S210001
Standards DIN EN 54-3
General remarks Cover plate available upon request
Parallel Indicator
Art.-no. 31193 - Type PA
Description:
Intelligent detector parallel indicator for the external optical
indication of the installation place of one or more detectors
Technical data
Properties
White wall mounting housing, red colour
Aestethical robust wall mounted housing according with IP 30
Operation voltage 24 V DC
Alarm current 4 mA
Ambient temperature -10°C to +50°C
Weight Approx. 65 g
Material ABS
Dimensions (H x W x D) 84 mm x 84 mm x 35 mm
CPD-Number 0786-CPD-20765
VdS approval G294052
System approval S295054, S208123 and S210001
14. Conventional signalling devices 95
Beacon, red
Art.-no. 32462 - Type SOLEX 10 r
Beacon, orange
Art.-no. 30220 - Type SOLEX 10 o
Beacon, blue
Art.-no. 32448 - Type SOLEX 10 b
Beacon, green
Art.-no. 32447 - Type SOLEX 10 g
Description:
Optical Xenon-beacon for an external optical alarm
accord. to DIN EN 54-23
Technical data
Properties:
Huge input voltage range
Automatic synchronisation
Integrated starting current limitation
High efficiency
Flat design
Accessories: Flush mounted base for IP 65, white, Art.-no. 40060, Type UB w
Flush mounted base for IP 65, red, Art.-no. 40059, Type UB r
Flush mounted base 48 mm for IP 65, white, Art.-no. 31467, Type PG DG w
Flush mounted base 48 mm for IP 65, red, Art.-no. 31468, Type PG DG r
Operation voltage 10 - 60 V DC
Alarm current 45 to 185 mA, 80 mA at 24 V
Efficacy 10 Cd
Flash frequency 1 Hz +/- 20%
Ambient temperature -25°C to +70°C
Weight 150 g
Protection class IP 54
Colour housing Red (Art.-no. 32462) or white (Art.-no 30220, 32447, 32448)
Material Base ABS, lense PC
Dimensions (H x Ø) 67 mm x 93 mm
VdS approval G207018
System approval S295054, S208123 and S210001
Standards DIN EN 54–23
14. Conventional signalling devices 96
red version
Technical data
Properties:
Robust flush-mounted base made of plastic
Snap on mounting for sirens (ROLP) and beacons (SOLEX)
Ambient temperature -25°C to +70°C
Weight 10 g
Protection class IP 65
Colour housing Red (Art.-no. 40059) or white (Art.-no. 40060)
Material ABS
Dimensions (H x Ø) 51 mm x 92 mm
red version
Technical data
Properties:
Robust finery-mounted base made of plastic
Suitable for PG cable entry
Snap on mounting for sirens (ROLP) and beacons (SOLEX)
Ambient temperature -25°C to +70°C
Weight 10 g
Protection class IP 65
Colour housing Red (Art.-no. 31468) or white (Art.-no. 31467)
Material ABS
Dimensions (H x Ø) 48 mm x 92 mm
14. Conventional signalling devices 97
Beacon, red
Art.-no. 32056 - Type VXB 1 SB WB RL
Beacon, orange
Art.-no. 32142 - Type VXB 1 SB WB AL
Description:
Optical LED-signalling device for the external optical alarm
red version
Weight 145 g
Protection class IP 43
Dimensions (H x Ø) 60 mm x 95 mm
Beacon, red, IP65
Art.-no. 32057 - Type VXB 1 DB WB RL
Beacon, orange, IP 65
Art.-no. 32200 - Type VXB 1 DB WB AL
Description:
Optical LED-signalling device for the external optical alarm
red version
Weight 165 g
Protection class IP 65
Dimensions (H x Ø) 80 mm x 95 mm
Technical data for all above beacons
Properties:
LED - beacon with low current consumption
Flat design
Light power 0,7 Watt at 5 mA current consumption
Light power 0,4 Watt at 3 mA current consumption
Operation voltage 20-35 V DC
Alarm current 3 to 5 mA
Efficacy 0,4 to 0,7 W
Flash frequency 1 Hz
Ambient temperature -20°C to +70°C
Colour housing White
Material ABS
14. Conventional signalling devices 98
Flat design
Weight 233 g
Protection class IP 43
Dimensions (H x Ø) 90 mm x 94 mm
Sounder/ beacon combination IP 65
Art.-no. 32063 - Type VTB 32 DB W
Description:
Combination of optical and acoustic signaling devices for
external alarm
Technical data
Properties:
Clear display and easy operation with LED displays and operation keys
Connection possibility for 2 conventional zones for the use with the
CT 3000 fire detection components with up to 20 detectors per zone
Integrated power supply accord. to EN 54-4: 1997/A2: 2006
with 1 output for external devices rated at 24V DC
2 monitored outputs with 300 mA each for signalling devices
2 potentialfree relay outputs for alarm and fault
Emergency power supply via 1 battery 12V / up to 7 Ah
Independent connection of detector and signalling device zones
Integrated "one-man-revision mode"
2 access levels via key switch
Manual control of signalling devices via seperate input
Cabling: - Maximum wire diameter of 2,3 mm
Length: -Max. length of 1,1 km (0,8 mm²) E.G. JY (ST) Y 2 X 2 0,8 mm² -max. length of 3 km (2,3 mm²)
Different languages available on request
Supply voltage 230V AC ± 10%
Power supply 24V DC/300 mA
Emergency supply 1 x 12 V/7 Ah
Quiescent current 2 to 10 mA
Alarm current 10 to 110 mA
Short circuit ≥ 110 mA
Conventional line broken wire/ fault 0 to 2 mA
Display 21 LEDs for status display, thereof 11 LEDs masked
6 keys for operation
Outputs 2 x 24 V/300 mA monitored for signalling devices
2 relay outputs 60 V DC/120 V AC /3A for alarm and fault
Ambient temperature -5°C to +40°C
Humidity 0 to 95 % (non-condensing)
Stock temperature -20°C to +60°C
Protection class IP 30
Colour Grey (similar to RAL 7035)
Material ABS
Dimensions (H x W x D) 288 mm x 340 mm x 98 mm
Weight 2,30 kg (without battery)
CPD-number 1293-CPD-0132
Standards EN 54-2: 1997/A1: 2006; EN 54-4: 1997/A2: 2006
15. Conventional Fire Alarm Systems 100
Technical data
Properties:
Clear display and easy operation with LED displays and operation keys
Connection possibility for 4 conventional zones for the use with the
CT 3000 fire detection components with up to 20 detectors per zone
Integrated power supply accord. to EN 54-4: 1997/A2: 2006
with 1 output for external devices rated at 24V DC
2 monitored outputs with 300 mA each for signalling devices
2 potentialfree relay outputs for alarm and fault
Emergency power supply via 1 battery 12V / up to 7 Ah
Independent connection of detector and signalling device zones
Integrated "one-man-revision mode"
2 access levels via key switch
Manual control of signalling devices via seperate input
Cabling: - Maximum wire diameter of 2,3 mm
Length: -Max. length of 1,1 km (0,8 mm²) E.G. JY (ST) Y 2 X 2 0,8 mm² -max. length of 3 km (2,3 mm²)
Different languages available on request
Supply voltage 230V AC ± 10%
Power supply 24V DC/300 mA
Emergency supply 1 x 12 V/7 Ah
Quiescent current 2 to 10 mA
Alarm current 10 to 110 mA
Short circuit ≥ 110 mA
Conventional line broken wire/ fault 0 to 2 mA
Display 25 LEDs for status display, thereof 11 LEDs masked
6 keys for operation
Outputs 2 x 24 V/300 mA monitored for signalling devices
2 relay outputs 60 V DC/120 V AC /3A for alarm and fault
Ambient temperature -5°C to +40°C
Humidity 0 to 95 % (non-condensing)
Stock temperature -20°C to +60°C
Protection class IP 30
Colour Grey (similar to RAL 7035)
Material ABS
Dimensions (H x W x D) 288 mm x 340 mm x 98 mm
Weight 2,30 kg (without battery)
CPD-number 1293-CPD-0132
Standards EN 54-2: 1997/A1: 2006; EN 54-4: 1997/A2: 2006
15. Conventional Fire Alarm Systems 101
Technical data
Properties:
Clear display and easy operation with LED displays and operation keys
Connection possibility for 8 conventional zones for the use with the
CT 3000 fire detection components with up to 20 detectors per zone
Extension option for 8 conventional zones for up to 16 conventional zones for CT 3000 components
Integrated power supply accord. to EN 54-4: 1997/A2: 2006
4 monitored outputs with 300 mA each for signalling devices
2 potentialfree relay outputs for alarm and fault
Emergency power supply via 1 battery 18V / up to 7 Ah
Independent connection of detector and signalling device zones
Integrated "one-man-revision mode"
Manual control of signalling devices via seperate input
Panel network of max. two fire control panels
Cabling: - Maximum wire diameter of 2,3 mm
Maximum zone lenght 2000 m
Different languages available on request
Supply voltage 230V AC ± 10%
Power supply 24V DC/1 A
Emergency supply 1 x 12 V/18 Ah
Quiescent current 2 to 10 mA
Alarm current 10 to 110 mA
Short circuit ≥ 110 mA
Conventional line broken wire/ fault 0 to 2 mA
Display 16 LEDs for status display (+ 8 LEDs in case of extension)
6 keys for operation and programming
Outputs 2 x 24 V/300 mA monitored for signalling devices
2 relay outputs 60 V DC/120 V AC /3A for alarm and fault
Ambient temperature -5°C to +40°C
Humidity 0 to 93 % (non-condensing)
Stock temperature -20°C to +60°C
Protection class IP 30
Colour Grey (similar to RAL 7035)
Material ABS
Dimensions (H x W x D) Outer dimensions 345 mm x 455 mm x 128 mm
Weight 4,26 kg (without battery)
CPD-number 1293-CPD-0133
Standards EN 54-2: 1997/A1: 2006; EN 54-4: 1997/A2: 2006
Accessories 4 zone extension module Art.-no. 32653 Type GE
4 alarm zones extension Art.-no. 32654 Type SE 4
Relay-module, 8 relays 1 A/12 V Art.-no. 32655 Type RM 8
15. Conventional Fire Alarm Systems 102
Technical data
Properties:
Integrated professional smoke detection system with highest reliability for a
secure alarm verification with 16 fold measurement and intelligent logics
Integrated temperature measurement as rate of rise procedure and maximum value
in accordance to EN 54-5
Intelligent analysis and disruption mode for the elimination of false alarms
Periodic sensor tests of the analyzing chamber
Alarm output for the triggering of a LED indicators
Multicolour-LED for alarm (red) and fault (yellow)
Integrated locking system for the protection against removal and tamper.
Delivery including protective cover for installation phase
Operation voltage 9 to 33 V DC
Quiescent current 100 μA
Alarm current 20 mA
OC-outputs max. 50 mA for LED-indicator or piezo buzzer
Sensitivity 60° differential temperature or smoke < 0,15 dB / m
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Air speed < 20 m/s
Protection class IP 40
Colour housing White (similar to RAL 9003)
Material ABS
Dimensions (H x Ø) 52 mm x 100 mm
Standards DIN EN 54-5 and 7
15. Conventional Fire Alarm Systems 103
Technical data
Properties:
Integrated professional smoke detection system with highest reliability for a
secure alarm verification with 16 fold measurement and intelligent logics
Intelligent analysis and disruption mode for the elimination of false alarms
Periodic sensor tests of the analyzing chamber
Alarm output for the triggering of a LED indicators
Multicolour-LED for alarm (red) and fault (yellow)
Integrated locking system for the protection against removal and tamper
Delivery including protective cover for installation phase
Operation voltage 9 to 33 V DC
Quiescent current 100 μA
Alarm current 20 mA
OC-outputs max. 50 mA for LED-indicator or piezo buzzer
Sensitivity 60° differential temperature or smoke < 0,15 dB / m
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Air speed < 20 m/s
Protection class IP 40
Colour housing White (similar to RAL 9003)
Material ABS
Dimensions (H x Ø) 44 mm x 100 mm
CPD-Number 0786-CPD-20042
VdS approval G203036
System approval S295054, S208123 and S210001
Standards DIN EN 54-5 and 7
15. Conventional Fire Alarm Systems 104
Heat detector with fixed & rate of rise temperature settings for conventional systems
Art.-no. 30014 - Type CT 3000 T
Description:
Heat detector with fixed and rate of rise temperature
settings for conventional systems for earliest fire detection
and indication in all environments with difficult ambient
conditions according to DIN EN 54-5
Technical data
Properties:
Integrated temperature measurement as rate of rise procedure and maximum value
in accordance to EN 54-5
Periodic sensor tests of the analyzing chamber
Alarm output for the triggering of a LED indicators
Multicolour-LED for alarm (red) and fault (yellow)
Integrated locking system for the protection against removal and tamper
Delivery including protective cover for installation phase
Operation voltage 9 to 33 V DC
Quiescent current 80 μA
Alarm current 20 mA
OC-outputs max. 50 mA for LED-indicator or piezo buzzer
Sensitivity Differential temperature
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Air speed < 20 m/s
Protection class IP 40
Colour housing White (similar to RAL 9003)
Material ABS
Dimensions (H x Ø) 52 mm x 100 mm
Standards DIN EN 54-5
15. Conventional Fire Alarm Systems 105
Technical data
Properties:
Integrated professional smoke detection system with highest reliability for a
secure alarm verification with 16 fold measurement and intelligent logics
Intelligent analysis and disruption mode for the elimination of false alarms
Periodic sensor tests of the analyzing chamber
Alarm output for the triggering of a LED indicators
Multicolour-LED for alarm (red) and fault (yellow)
Integrated locking system for the protection against removal and tamper
Delivery including protective cover for installation phase
Operation voltage 9 to 33 V DC
Quiescent current 100 μA
Alarm current 20 mA
OC-outputs max. 50 mA for LED-indicator or piezo buzzer
Sensitivity 60° differential temperature or smoke < 0,15 dB / m
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Air speed 20 m/s
Protection class IP 40
Colour housing White (similar to RAL 9003)
Material ABS
Dimensions (H x Ø) 44 mm x 100 mm
CPD-Number 0786-CPD-20308
VdS approval G 206097
System approval S295054, S208123 and S210001
Standards DIN EN 54-5
Technical data
Dimensions (H x Ø) 42 mm x 95 mm
Material ABS, metal mesh
Standards DIN EN 54-7
For more technical details please see page 109.
15. Conventional Fire Alarm Systems 107
Technical data
Dimensions (H x Ø) 47 mm x 110 mm
Material Glass, ABS
Standards DIN EN 54–7
Technical data
Dimensions (H x W x D) 44 mm x 122 mm x 122 mm
Material Glass, ABS
Standards DIN EN 54–7
For more technical details please see page 109.
15. Conventional Fire Alarm Systems 108
Technical data
Dimensions (H x Ø) 33 mm x 110 mm
Material ABS
Standards DIN EN 54-7
For more technical details please see page 109.
15. Conventional Fire alarm systems 109
Technical data
Properties:
Integrated connectors for LED indicator (Art.-no. 31193) or piezo buzzer (Art.-no. 32091)
Space for additional connectors Type WAGO 243
Integrated connectors for the connection of one spur for the loop extension (T-branch)
Mounting space for the piezo buzzer ( Art.-no. 32091) and the detector labelling clip (Art.-no. 30479)
Including transparent seal cover to protect the base against contaminents
Material ABS
Dimensions (H x Ø) 21 mm x 95 mm
15. Conventional Fire Alarm Systems 111
Technical data
Properties:
Triggering of the relays at alarm and removal of detector
Triggering of the relay only at alarm is possible
Compatible to all detetcors of series CT 3000
Suitable for the connection to 24 V-systems
Space for additional connectors Type WAGO 243
Mounting space for the detector labelling clip (Art.-no. 30479)
Including transparent seal cover to protect the base against contaminents
Operation voltage 18 to 30 V DC
Quiescent current 22 mA
Alarm current 0,4 mA
Outputs 1 change over contact 30 V / 1A
Ambient temperature -10°C to +60°C
Colour housing White (Art.-no. 30469), silver (Art.-no. 32086) or black (Art.-no. 32085)
Material ABS
Dimensions (H x Ø) 21 mm x 95 mm
Weight Approx. 60 g
VdS approval G207011
System approval S295054, S208123, S210001
15. Conventional Fire Alarm Systems 112
Technical data
Properties:
Triggering of the relays at alarm and removal of detector
Triggering of the relay only at alarm is possible
Compatible to all detetcors of series CT 3000
Suitable for the connection to 12 V-systems
Space for additional connectors Type WAGO 243
Mounting space for the detector labelling clip (Art.-no. 30479)
Including transparent seal cover to protect the base against contaminents
Operation voltage 10 to 15 V DC
Quiescent current 6 mA
Alarm current 0,7 mA
Outputs 1 change over contact 30 V / 1A
Ambient temperature -10°C to +60°C
Colour housing White (Art.-no. 32265), silver (Art.-no. 32266)
Material ABS
Dimensions (H x Ø) 21 mm x 95 mm
Weight Approx. 60 g
15. Conventional Fire Alarm Systems 113
Piezo buzzer
Art.-no. 32091 - Type SP
Description:
Accoustic piezo alarm buzzer for direct connection to all
detectomat detector bases for the local accoustic
signalling in occupied areas (e.g hotels, residential homes
etc.)
Technical data
Properties
Direct voltage supply via detector/ loop
Activation by parallel connection to the alarm LED of the detector
Local accoustic alarm
Loud accoustic signal due to external and free sound emission
Mechanically compatible to all detectomat standard detector bases
Volume Approx. 85 dB / 0.3 m
Colour housing White (similar RAL 9003)
Material ABS
Dimensions (H x W x D) 8 mm x 45 mm x 35 mm
Technical data
Properties
Plugs directly onto the detector base
Maximum character height of 25 mm
Pack contains 30 units
Volume Approx. 85 dB / 0.3 m
Colour housing White (similar RAL 9003)
Material ABS
Technical data
Properties
Integrated temperature-controlled heater for regulated ambient conditions for detectors.
Including Detector base SDB 3000
Integrated connectors for LED indicator (Art-no. 31193) or piezo buzzer (Art-no. 32091)
Space for additional connectors Type WAGO 243
Integrated connectors for the connection of one spur for the loop extension (T-branch)
Operation voltage 24 V DC
Current consumption 160 mA
Power max. 4 W
Ambient temperature -30°C to + 60°C
Protection class IP 66
Colour housing White
Dimensions (H x Ø) 335 g
Technical data
Properties
Integrated sealing against condensate and dripping water
2 cable entry points for cable glands M16
Without detector base
Colour housing White (similar RAL 9003)
Material ABS
Dimensions (H x Ø) 43,5 mm x 105 mm
Protection class IP 66
Weight 40 g
15. Conventional Fire Alarm Systems 116
Technical data
Properties
Protection of the detector against foreign objects like e.g. balls or other objects with a solid metal grid
Compatible to detectors of the design variants 0, 1 and 2
Installation of the protection cage after the detector installation
with three fixation points (screw fixation)
Cable entry from the back required for the detector base
Colour White
Material Steel
Dimensions (H x Ø) 75 mm x 150 mm
Weight Approx. 150 g
Technical data
Properties
Protection of the detector, siren or beacon against foreign objects
like e.g. balls or other objects with a solid metal grid
Installation of the protection cage after the device installation (screw fixation)
Cable entry from the back required for the detector base, siren and beacon
Colour White
Material Steel
Dimensions (H x Ø) 160 mm x 120 mm
Weight Approx. 140 g
15. Conventional Fire Alarm Systems 117
Technical data
Properties:
Steplessly variable from 270 to 480 mm
Angle of the detector bracket stepless adjustable from 0° to 110°
Rear cable entry in the detector possible
Colour RAL 7035 light grey
Material Sheet steel powder coated
Dimensions (H x W x D) 135 mm x 100 mm x 270 mm to 480 mm
Weight 1.200 g
Technical data
Properties:
Distance to the wall: 400 mm
Rear cable entry in the detector possible
Colour RAL 7035 light grey
Material Sheet steel powder coated
Dimensions (H x W x D) 50 mm x 100 mm x 400 mm
Weight 770 g
Technical data
Properties:
Distance to the wall: 200 mm
Rear cable entry in the detector possible
Colour RAL 7035 light grey
Material Sheet steel powder coated
Dimensions (H x W x D) 50 mm x 100 mm x 200 mm
Weight 390 g
15. Conventional Fire Alarm Systems 119
Technical data
Properties
Spring buttom detector mechanics for the activation of a manual alarm
Non-destructive activation and reset via mechanics
Operation voltage up to 30 V DC
Alarm current 27 mA
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Protection class IP 42
Colour housing Red (RAL 3000)
Material ABS
Dimensions (H x W x D) 88 mm x 88 mm x 54 mm
Standards DIN EN 54-11
15. Conventional Fire Alarm Systems 120
Technical data
Properties
Push Button mechanics for the activation of a manual alarm
Activation after smash of the front glass and button push
Integrated reset mechanics (operation from inside)
Integrated red alarm-LED
Lockable plastic housing
Operation voltage 12 to 24 V DC
Alarm current 27 mA
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Protection class IP 42
Colour housing Red (RAL 3000)
Material ABS
Dimensions (H x W x D) 135 mm x 135 mm x 33 mm
Colour housing Red (RAL 3000)
CPD-Number 0786-CPD-20526
VdS approval G296033
System approval S295054, S208123 and S210001
Standards DIN EN 54-11
Accessories Spare glass (Art.-no. 31910)
Spare key metal (Art.-no. 40054)
General remarks A plastic key comes with every 10 manual call points
Spare key
Art.-no. 40054 - Type HFM SCH M
15. Conventional Fire Alarm Systems 121
Technical data
Properties
Push Button mechanics for the activation of a manual alarm
Activation after smash of the front glass and button push
Integrated reset mechanics (operation from inside)
Integrated red alarm-LED
Lockable aluminium housing
Operation voltage 12 to 24 V DC
Alarm current 27 mA
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Protection class IP 42
Colour housing Red (RAL 3000)
Material Aluminium
Dimensions (H x W x D) 125 mm x 125 mm x 34 mm
Colour housing Red (RAL 3000)
CPD-Number 0786-CPD-20350
VdS approval G202034
System approval S295054, S208123 and S210001
Standards DIN EN 54-11
Accessories Spare glass (Art.-no. 31910)
Spare key metal (Art.-no. 40054)
Wheatherproof housing (Art.-no. 31091)
General remarks A metal key comes with every 10 manual call points
Suitable for a wheatherproof housing
Technical data
Properties
Robust aluminium protective housing
Including seal and gasket set for the mounting of the housing
Sealing and gasket set for a protected cable entry
Ambient temperature -10°C to +60°C
Humidity max. 93 % (+/-2%)
Protection class IP 54
Weight Approx. 295 g
Colour housing Red (RAL 3000)
Material Aluminium
Dimensions (H x W x DT) 145 mm x 131 mm x 55 mm
Spare key
Art.-no. 40054 - Type HFM SCH M
Technical data
Properties
Key for opening of all manual call points fo the series PL and CT
Die-casting design, metal
15. Conventional Fire Alarm Systems 123
Technical data
Properties
Push Button mechanics for the activation of a manual alarm
Integrated reset mechanics (operation from inside)
Flame and UV resistant plastic housing
Operation voltage 12 to 28 V DC
Alarm current Approx. 30 mA
Ambient temperature -35°C to +60°C
Protection class IP 66
Colour housing Red (RAL 3000)
Material PC
Dimensions (H x W x D) 135 mm x 135 mm x 61 mm
Weight 475 g
CPD-Number 0786-CPD-20309
VdS approval G206113
System approval S295054, S208123 and S210001
Standards DIN EN 54-11
16. Wireless Fire Alarm Systems 124
Technical data
Properties:
Integrated display with backlight
Connection of up to 100 radio devices
Enables the connection of up to 3 repeaters for extension of the transmission path
6 alarm zones with LEDs
9 status-LEDs
Individual identification of all radio devices with addresses
Monitoring of the radio devices relating to individual battery condition, fault,
radio transmission and life-signal
Control of all alarm and status messages with plausibiity check
4 potentialfree output relays, freely programmable, SUB-D plug type connector
Integrated power supply and emergency battery set for the backup of
the power supply in case of power failure
Emergency supply with 8 batteries Mignon LR6
External input for 12V-supply
Different access levels with password protection
Comprehensive service and analysis mode
Supply voltage 230 V AC / 50 Hz (+/-10%)
Power supply 12 V DC
Emergency supply 8 x Mignon LR6 for approx. 60 hours
Nominal current 35 m A (LED operation) up to 120 mA
(4 relays in quiescent current operation)
Alarm current max 160 mA depending on mode of operation
Radio frequency 433,42 MHz (ISM-band)
Radio transmission power 10 mW ERP
Display LC-Display, backlight, 15 LEDs - for status indication
Outputs 4 relays outputs 30 V AC / 1 A, SUB - D plug type connector, 9 poles
internal acoustic signal (85 db/ 1m)
Ambient temperature 0°C to +60 °C
Humidity 5-95 % (non-condensing)
Protection class IP 30
Colour Grey
Material ABS
Dimensions (H x W x D) 170 mm x 170 mm x 55 mm
Weight 800 g
Optional accessories Relay-connection cable for SRC 3000, Art.-no. 32294, Type F.BZ
12 V connection cable for external supply, Art.-no. 32327, Type AK
General remarks Scope of delivery including 8 Mignon LR6
16. Wireless Fire Alarm Systems 125
Smoke alarm, optical home detector, wireless link module, wired network
Art.-no. 30458 - Type HDv® 3000 O
Description:
Intelligent stand alone smoke detector for early detection giving
a local acoustic alarm in private and domestic applications in
accordance to EN 14604 for the use in applications with
demanding requirements e.g. caravan- and camper vans again
in accordance to EN 14604 Annex L
Includes a lithium battery for the long term operation
Technical data
Properties:
Integrated professional smoke measuring chamber with the highest reliability
for secure alarm verifications via 16 fold measurements and intelligent logics
Intelligent analysis and disruption mode for the elimination of false alarms
Inspected pollution resistance, integrated pollution recognition and fault indication
in the cases of contaminated environments
Periodic sensor tests of the smoke chamber
Pre-alarm for condensation, consequently suitable for the use in kitchens and bathrooms
Intelligent technology for smoke measurement under variations in temperature,
no additional cost intensive heat sensor required
Easy activation of the test-function via LED-mechanism
Complies with industrial standards in accordance to IPC 2
Includes an alkaline battery for the long term operation
Special designed housing for optimal smoke entry and acoustic alarm signal transmission
Integrated Piezo-buzzer for a loud acoustic alarm (> 85dB)
Integrated LED displaying alarm and fault conditions
Suitable for use in applications with demanding requirements
e.g. vehicles in accordance to EN 14604 Annex L
Integrated locking system for the protection against removal and tamper.
Indication of maintenance and service via optical and acoustic signals
Suitable for a number of different fixing methods
Easy mounting of the detectors in the base using Click-In-Technology
Integrated interface for wireless link modules for the additional functionality of the smoke detection as
part of a linked system
Ambient temperature -10°C to +60°C
Battery lifetime Approx. 10 years, when used as Stand-Alone-Detector
under normal temperatures (15-25°C), Test accord. to DIN 14676
Humidity max. 95 % (+/-2%)
Air speed < 20m/s
Protection Class IP 40
Housing colour White (similar to RAL 9003)
Material ABS
Dimensions (H x Ø) 52 mm x 100 mm
Weight Approx. 160g
CPD-Number 0786-CPD-20302 and 0786-CPD-20681
VdS approval G202042
Accessories Anti tamper pin (Art.-no. 32301)
Anti tamper screws (Art.-no. 50437)
Adhesive pad (Art.-no. 32587)
Standards EN 14604
16. Wireless Fire Alarm Systems 126
Technical data
Properties:
Transmission of all alarm and status messages with plausibility check
Bidirectional data exchange with the radio wireless fire control panel SRC 3000
Enables the activation of the back up alarm of all devices of the system
Micro switch for the teach in function with display of the signal strength at the panel display
Integrated switchable acoustic signal for the receipt of alarms
Individual identification of all radio devices with addresses
Monitoring relating to individual battery condition, fault, radio transmission and life-signal
Operation voltage 9 V DC
Emergency supply via HDv® 3000
Quiescent current 36 µA
Alarm current 18 mA (radio reception) to 35 mA (transmission)
Radio frequency 433,42 MHz (ISM-band)
Display LED
Ambient temperature 0°C to +55 °C
General remarks Suitable for the HDv® 3000 O and design variants
Technical data
Properties:
Transmission of all alarm and status messages with plausibility check
Bidirectional data exchange with the radio wireless fire control panel SRC 3000
Enables the activation of the back up alarm of all devices of the system
Micro switch for the teach in function with display of the signal strength at the panel display
Integrated switchable acoustic signal for the receipt of alarms
Individual identification of all radio devices with addresses
Operation voltage 9 V DC
Emergency supply via TM
Quiescent current 36 µA
Alarm current 18 mA (radio reception) to 35 mA (transmission)
Radio frequency 433,42 MHz (ISM-band)
Display LED
Ambient temperature 0°C to +55 °C
General remarks Suitable for the TM detector
16. Wireless Fire Alarm Systems 127
Technical data
Properties:
Integrated temperature measurement as maximum value
Alarm temperature 60°C
Integrated Piezo-alarm for a loud acoustic alarm (> 85dB)
Periodic sensor test with signaling of a sensor defect
Integrated LED for alarm and fault messages
Display of maintenance and service via optical and acoustic signals
Integrated interface for wireless link modules for the additional functionality of the detection
as part of a linked system
Scope of supply including batteries and fixing material
Operation voltage 9 V DC
Quiescent current max. 16 μA
Alarm current max. 20 mA
Output 4 Relais 50 V / 0,5 A
Response sensitivity 60°C
Ambient temperature 0°C to +60°C
Humidity max. 80 % (+/-2%)
Protection class IP 20
Colour housing White
Material ABS
Dimensions (H x Ø) 70 mm x 80 mm
16. Wireless Fire Alarm Systems 128
Technical data
Properties:
Transmission of all alarm and status messages with plausibility check
Bidirectional data exchange with the radio wireless fire control panel SRC 3000
Enables the activation of the back up alarm of all devices of the system
Integrated Piezo - alarm for a loud acoustic alarm (> 85dB)
Integrated LED for alarm and fault messages
Display of maintenance and service via optical and acoustic signals
Micro switch for the teach in function with display of the signal strength at the panel display
Integrated switchable acoustic signal for the receipt of alarms
Individual identification of all radio devices with addresses
Monitoring relating to individual battery condition, fault, radio transmission and life-signal
Scope of delivery including batteries
Operation voltage 6 V DC
Emergency supply Integrated warning signal for low battery
Quiescent current 40 µA
Alarm current 40 mA
Radio frequency 433,42 MHz (ISM-band)
Display LED
Ambient temperature 0°C to +55°C
Protection class IP 42
Colour housing Blue
Material ABS
Dimensions (H x W x D) 120 mm x 120 mm x 31 mm
16. Wireless Fire Alarm Systems 129
Technical data
Properties:
Transmission of all alarm and status messages with plausibility check
Bidirectional data exchange with the radio wireless fire control panel SRC 3000
Enables the activation of the back up alarm of all devices of the system
Micro switch for the teach in function with display of the signal strength at the panel display
Individual identification of all radio devices with addresses
Scope of delivery including batteries
Operation voltage 9 V DC
Emergency supply Integrated warning signal for low battery
Quiescent current 7,5 µA
Alarm current 40 mA
Radio frequency 433,42 MHz (ISM- band)
Ambient temperature 0°C to +55°C
Protection class IP 42
Colour housing Red
Material ABS
Dimensions (H x W x D) Dimensions (H x W x D)
16. Wireless Fire Alarm Systems 130
Technical data
Properties:
Red XENON beacon with 0,7 J energy according to EN 54-23
32 tone sirene with 101 dB, synchronized
Transmission of all alarm and status messages with plausibility check
Bidirectional data exchange with the radio wireless fire control panel SRC 3000
Display of maintenance and service via optical and acoustic signals
Micro switch for the teach in function with display of the signal strength at the panel display
Integrated switchable acoustic signal for the receipt of alarms
Individual identification of all radio devices with addresses
Monitoring relating to individual battery condition, fault, radio transmission and life-signal
Scope of delivery including batteries
Operation voltage 6 V DC
Emergency supply Integrated warning signal for low battery
Quiescent current 45 µA
Alarm current 150 mA
Luminous intensity 0,7 J
Volume 101 dB (adjustable to a lower value)
Radio frequency 433,42 MHz (ISM-band)
Display LED
Ambient temperature 0°C to +55°C
Protection class IP 65
Colour housing Blue
Material Base ABS, lense PC
Dimensions (H x W x D) 93 mm x 121 mm
16. Wireless Fire Alarm Systems 131
Technical data
Properties:
Connection of up to 10 devices per repeater
Connection of up to 3 repeaters per SRC 3000 system
Display of the actual radio signal strength at the programming
Transmission of all alarm and status messages with plausibility check
Bidirectional data exchange with the radio wireless fire control panel SRC 3000
Enables the activation of the back up alarm of all devices of the system
Integrated emergency supply battery
Integrated LED for alarm and fault messages
Display of maintenance and service via optical and acoustic signals
Individual identification of all radio devices with addresses
Monitoring relating to individual battery condition, fault, radio transmission and life-signal
Scope of delivery including batteries and power supply
Supply voltage 230 V AC via AC adaptor plug
Operation voltage 12 V DC
Emergency supply 9 V (for 8 hours)
Quiescent current max. 35 mA
Alarm current max. 70 mA
Radio frequency 433,42 MHz (ISM-band)
Display 5 LEDs-status indication
Ambient temperature 0°C to +60 °C
Protection class IP 20
Colour housing Grey
Material ABS
Dimensions (H x W x D) 158 mm x 195 mm x 45 mm
16. Wireless Fire Alarm Systems 132
Technical data
Properties:
1 input as connection option for a potential free contact
Display of the actual radio signal strength at the programming
Transmission of all alarm and status messages with plausibility check
Bidirectional data exchange with the radio wireless fire control panel SRC 3000
Enables the activation of the back up alarm of all devices of the system
Micro switch for the teach in function with display of the signal strength at the panel display
Individual identification of all radio devices with addresses
Monitoring relating to individual battery condition, fault, radio transmission and life-signal
Scope of delivery including batteries
Operation voltage 9 V DC
Emergency supply Integrated warning signal for low battery
Quiescent current max 35 µA
Alarm current 25 mA
Radio frequency 433,42 MHz (ISM - band)
Ambient temperature 0°C to +60 °C
Protection class IP 42
Colour housing Grey
Material ABS
Dimensions (H x W x D) 92 mm x 57 mm x 30 mm
17. Smoke alarm detectors and accessories 133
Smoke alarm, optical home detector, wireless link module, wired network
Art.-no. 30458 - Type HDv® 3000 O
Description:
Intelligent stand alone smoke detector for early detection giving
a local acoustic alarm in private and domestic applications in
accordance to EN 14604 for the use in applications with
demanding requirements e.g. caravan- and camper vans again
in accordance to EN 14604 Annex L
Includes a lithium battery for the long term operation
Technical data
Properties:
Integrated professional smoke measuring chamber with the highest reliability
for secure alarm verifications via 16 fold measurements and intelligent logics
Intelligent analysis and disruption mode for the elimination of false alarms
Inspected pollution resistance, integrated pollution recognition and fault indication
in the cases of contaminated environments
Periodic sensor tests of the smoke chamber
Pre-alarm for condensation, consequently suitable for the use in kitchens and bathrooms
Intelligent technology for smoke measurement under variations in temperature,
no additional cost intensive heat sensor required
Easy activation of the test-function via LED-mechanism
Complies with industrial standards in accordance to IPC 2
Includes an alkaline battery for the long term operation
Special designed housing for optimal smoke entry and acoustic alarm signal transmission
Integrated Piezo-buzzer for a loud acoustic alarm (> 85dB)
Integrated LED displaying alarm and fault conditions
Suitable for use in applications with demanding requirements
e.g. vehicles in accordance to EN 14604 Annex L
Integrated locking system for the protection against removal and tamper.
Indication of maintenance and service via optical and acoustic signals
Suitable for a number of different fixing methods
Up to 40 smoke detectors of the HD range can be linked together to increase the alarm area
Easy mounting of the detectors in the base using Click-In-Technology
Integrated interface for wireless link modules for the additional functionality of the smoke detection as
part of a linked system
Ambient temperature -10°C to +60°C
Battery lifetime Approx. 10 years, when used as Stand-Alone-Detector
under normal temperatures (15-25°C), Test accord. to DIN 14676
Humidity max. 95 % (+/-2%)
Air speed < 20m/s
Protection Class IP 40
Housing colour White (similar to RAL 9003)
Material ABS
Dimensions (H x Ø) 52 mm x 100 mm
Weight Approx. 160g
CPD-Number 0786-CPD-20302 and 0786-CPD-20681
VdS approval G202042
Accessories Anti tamper pin (Art.-no. 32301); Anti tamper screws (Art.-no. 50437)
Adhesive pad (Art.-no. 32587)
Standards EN 14604
17. Smoke alarm detectors and accessories 134
Smoke alarm, optical home detector, wireless link module, mesh design, white
Art.-no. 30023 - Type HD 3001 O white
Description:
Intelligent stand alone smoke detector for early detection giving
a local acoustic alarm in private and domestic applications in
accordance to EN 14604 for the use in applications with
demanding requirements e.g. caravan- and camper vans again
in accordance to EN 14604 Annex L
Includes a lithium battery for the long term operation
White mesh design
Smoke alarm, optical home detector, wireless link module, mesh design, silver
Art.-no. 30024 - Type HD 3001 silver
Description:
Intelligent stand alone smoke detector for early detection giving
a local acoustic alarm in private and domestic applications in
accordance to EN 14604 for the use in applications with
demanding requirements e.g. caravan- and camper vans again
in accordance to EN 14604 Annex L
Includes a lithium battery for the long term operation
Silver mesh design
Smoke alarm, optical home detector, wireless link module, mesh design, black
Art.-no. 30123 - Type HD 3001 O black
Description:
Intelligent stand alone smoke detector for early detection
giving a local acoustic alarm in private and domestic
applications in accordance to EN 14604 for the use in
applications with demanding requirements e.g. caravan-
and camper vans again in accordance to
EN 14604 Annex L
Includes a lithium battery for the long term operation
Black mesh design
Technical data
Dimensions (H x Ø) 42 mm x 95 mm
Material ABS, Aluminium
Weight Approx. 140 g
CPD - Number 0786-CPD-20303
VdS approval G202054
Standards EN 14604
Properties and general technical data similar to HDv® 3000 O.
17. Smoke alarm detectors and accessories 135
Smoke alarm, optical home detector, wireless link module, glass design white
Art.-no. 32015 - Type HD 3005 O white
Description:
Intelligent stand alone smoke detector for early detection
giving a local acoustic alarm in private and domestic
applications in accordance to EN 14604 for the use in
applications with demanding requirements e.g. caravan-
and camper vans again in accordance to
EN 14604 Annex L
Includes a lithium battery for the long term operation
Glass design white
Smoke alarm, optical home detector, wireless link module, glass design silver
Art.-no. 32004 - Type HD 3005 O silver
Description:
Intelligent stand alone smoke detector for early detection
giving a local acoustic alarm in private and domestic
applications in accordance to EN 14604 for the use in
applications with demanding requirements e.g. caravan-
and camper vans again in accordance to
EN 14604 Annex L
Includes a lithium battery for the long term operation
Glass design silver
Technical data
Dimensions (H x Ø) 56 mm x 110 mm
Material Glass, ABS
Weight Approx. 320 g
CPD - Number 0786-CPD-20307
VdS approval G204091
Standards EN 14604
Smoke alarm, optical home detector, wireless link module square glass design white
Art.-no. 32292 - Type HD 3006 O white
Description:
Intelligent stand alone smoke detector for early detection
giving a local acoustic alarm in private and domestic
applications in accordance to EN 14604 for the use in
applications with demanding requirements e.g. caravan-
and camper vans again in accordance to
EN 14604 Annex L
Includes a lithium battery for the long term operation
Square glass design white
Technical data
Dimensions (W x D) 122 mm x 122 mm
Material Glass, ABS
Standards EN 14604
Properties and general technical data similar to HDv® 3000 O.
17. Smoke alarm detectors and accessories 136
Smoke alarm, optical home detector, wireless link module, flat design white
Art.-no. 32290 - Type HD 3007 O white
Description:
Intelligent stand alone smoke detector for early detection
giving a local acoustic alarm in private and domestic
applications in accordance to EN 14604 for the use in
applications with demanding requirements e.g. caravan-
and camper vans again in accordance to
EN 14604 Annex L
Includes a lithium battery for the long term operation
Round flat design, white colour
Technical data
Dimensions (H x Ø) 56 mm x 110 mm
Material ABS
Standards EN 14604
Smoke alarm, optical home detector, wireless link module, flat design with logo
Art.-no. 32325 - Type HD 3008 O white
Description:
Intelligent stand alone smoke detector for early detection
giving a local acoustic alarm in private and domestic
applications in accordance to EN 14604 for the use in
applications with demanding requirements e.g. caravan-
and camper vans again in accordance to
EN 14604 Annex L
Round design, with individual logo, white colour
Technical data
Dimensions (H x Ø) 56 mm x 110 mm
Material ABS
Weight Approx. 320g
CPD - Number 0786-CPD-20859
VdS approval G208084
Standards EN 14604
Properties and general technical data similar to HDv® 3000 O.
Monitoring plomb
Art.-no. 32301 - Type SP 100
Technical data
Properties:
Extension module for all smoke alarms of the series HDv 3000 and HD 3000
without integral battery for the connection of external devices
Easy and fast assembly plug in module for the smoke alarm
Connection of external devices to the change over contact
External voltage supply for the connected device required
Supply of the module via battery of the smoke alarm
Ambient temperature -10°C to +60°C
Protection class IP 20
Humidity 5-95 % (non-condensing)
Colour Green
Dimensions (H x W x D ) 54 mm x 22 mm x 22 mm
Weight Approx. 10 g
Output 1 change over relay 30 V DC / 2 A
General remarks The lifetime of the battery of the smoke alarm is reduced
by using the relay module
Technical data
Properties:
Wireless interlink option for up to 40 smoke alarms without using a fire control panel
Bidirectional data exchange to othe wireless interlink modules
Enables the activation of the back up alarm of all devices of the system
Integrated repeater function for the for the extension of the transmission path to other network devices
Monitoring relating to individual battery condition, fault, radio transmission and life-signal
Operation voltage 9 V DC
Emergency supply via HDv® 3000 O
Quiescent current 36 µA
Alarm current up to 37 mA
Frequency 868 MHz (ISM-band)
Display LED
Ambient temperature 0°C to 55°C
General remarks Suitable for HDv® 3000 O and design variants
18. Infrared-Beam detectors and accessories 138
Technical data
Properties:
Detection of light and dark smoke
Range 5-100 m
Control width: max. 13m
Control height: max. 12m
Control area: 1300 m²
Monitored area and mounting accord. to DIN VDE 0833
Potential free relays for alarm and fault
Three sensitivities: 25%, 35% and 50%
Connection to the loop 3000 via IOM 3311
Operation voltage 11,5 to 28 V DC
Quiescent current 14 mA
Alarm current 22 mA
Output relay 2 x 30 V DC/1A
Ambient temperature -20°C to + 55°C
Protection class IP 50
Colour housing Grey
Colour front Grey
Material Sheet steel
Weight 2,14 kg
Dimensions (H x W x D) 265mm x 210mm x 85mm
Standards DIN EN 54-12
18. Infrared-Beam detectors and accessories 139
Technical data
Properties:
Modular design
Adjustment of the system to the local conditions
Automatic adjustment of the beam detector can be activated or deactivated
LCD display with optical menue navigation in the display for an easy operation
Connection to the loop 3000 via IOM 3311
Adjustment of the sensitivity with thresholdd values in the range of 10% to 60%
Connection to the loop 3000 via IOM 3311
Adjustment of the delay times individually for fire and fault from 2 to 30 seconds
Automatic compensation for moving buildings
For the distance range of 100m three additional prism (Art.-no. 32471) are required in addition to the
basic package.
Operation voltage 14 to 28 V DC
Quiescent current 8 to 12 mA
Alarm / Operation current 48 to 52 mA
Ambient temperature -10°C to 55°C
Humidity rel. 93% (non-condensing)
Protection class IP 54
Colour housing Grey / black
Weight 1,67 kg
Dimensions (H x W x D) 135mm x 134 mm x 134mm
Standards DIN EN 54-12
Technical data
Properties:
Automatic, optical self test
Microprocessor controlled heated optics
Reliable detection even in case of simultaneous faults
Detection of a N-Heptane fire of 0,1 m² size at a distance of up to 15 m
Fast response time (40 ms)
Visual range angle 90°
Multicolour LED for status display of operation, fault and alarm
Mounting bracket vibration-free according to MIL
Event memory
Maintenance mode via magnet
Modular housing design
Hazardous area proof: EX: 538 Ex II 2 GD, ATEX 132195, FM 3260
Scope of supply: detector, magnet and mounting bracket
Recommended cable: shielded cable with 0,5 mm² up to 2,5 mm²
Operation voltage 18 V up to 30 V DC
Alarm / operation current 550 mA
Interfaces RS-485 Modbus output, 4-20 mA
Potential free relays Alarm, Fault, additional alarm
Sensitivity N-Heptane: 0,1 m² in 15 m distance: < 15 seconds
Methan: 30 inch flame in 10,5 5 distance: < 10 seconds
Ambient temperature -40°C to +75°C
Humidity max. 95% - (for short time up to 100% condensing air)
Protection class IP 66
Colour housing Red
Material housing Cooperfree Aluminium or stainless steel 316
Dimensions (H x W x D) 119 mm x 122 mm x 246 mm
EX 538 Ex II 2 GD, ATEX 132195, FM 3260
Standards DIN EN 54-10; Cl. 1-3
19. Flame detectors 142
Technical data
Properties:
The ultraviolet light of the optical spectrum is analysed
Robust housing suitable for the application in rough industrial environment
High reliability against false alarms, like e.g. lightning or strong solar irradiation
High sensitivity
Covering range up to 50 m; Covering area up to 676 m²
Parametrization for different applications via DIP switch
Monitoring of the optical window against pollution (UV-range)
Function control and analysis of the measured values with microcontroller;
faults can be displayed at the detector or at a separate line
Multicolour LED for alarm (red) and fault (yellow)
Recomended cable: IY (St) Y 2x2x0,8 mm²
Including service interface and event memory
Including mounting base and mounting bracket
Operation voltage 7,6 V up to 30 V DC
Quiescent current Approx. 0,25 mA
Alarm / operation current Approx. 15 mA
Ambient temperature -20°C to +80°C
Protection class IP 67
Covering range up to 50 m
Covering area up to 676 m²
Max. cable length 700 m with 0,5 mm² cable
Colour housing Red / silver
Material housing Aluminium die casting
Weight 0,8 kg
Dimensions (H x Ø) 100 mm x 50 mm
Standards DIN EN 54-10; Cl. 1
General remarks Up to 8 FMX 5000 UV-flame detectors can be connected to one
conventional interface CP CLI or to one conventional module TCM 3000
20. Ex-proof components and accessories 143
Specially for areas where a fire involves high temperatures in an early stage of fire
Integrated professional smoke detection and temperature measurement
High sensitivity for fast burning flaming fires (including liquid fires)
EX Heat detector, conventional system
Art.-no. 32245 - Type WM Ex 50 Orbis IS
Description:
Heat detector for conventional systems in Ex-proof design
Dimensions (H x Ø): 50 mm (with base) x 100 mm
Weight: Approx. 0,085 kg
Standard: DIN EN 54-5; Cl. A1
Technical data
Properties:
Multisensor for early smoke detection and fast burning flaming fires
Good performance with white and black smoke
Resistant against pressure and wind
Fast commissioning
Sensor protection and measurement chamber design reducing the entry of parts and false alarms
Sensor with high reliability and reduction of false alarms
Algorithm for separation of temporarily abnormal values
Optional flashing LED for the indication of the normal operation status
Self learning modes for the ambient conditions
Extra confirmation for smoke before alarm activation
For the use in explosive areas the Ex-barrier EX-B1 (Art.-no. 31174) has to be used.
Detector base for this EX detector is Art.-no. 32247
Operation voltage 14 to 28 V DC
Quiescent current 85 µA / 24 V
Ambient temperature -40°C up to +60°C
Humidity max. 98%
Protection class IP 23 D
Colour housing White
Material Polycarbonate
Dimensions (H x Ø) 50 mm (with base) x 100 mm
Weight 0,105 kg
Power on time < 20 sec.
ATEX BAS06, ATEX 0007X
Standards DIN EN 54-7; Cl. A1
Technical data
Colour White
Material Polycarbonate
Dimensions (H x Ø) 23 mm x 100 mm
Weight 0,005 kg
ATEX BAS06, ATEX 0007X
20. Ex-proof components and accessories 145
Technical data
Properties:
Reverse voltage protection
Top hat rail mounting
Quiescent current 6 mA
Ambient temperature -10°C up to +60°C
Colour housing Green
Material ABS
Dimensions (H x W x D) 93mm x 20mm x 110mm
Weight 0,09 kg
Technical data
Properties:
Reverse voltage protection
Top hat rail mounting
Protection class IP 65
Colour housing Grey
Material ABS
Dimensions (H x W x D) 220 mm x 125 mm x 162 mm
20. Ex-proof components and accessories 146
Technical data
Properties:
Incl. DIN tone = 106 dB (A) at 1 m+/- 3 dB (DIN tone 9: 1200/500 Hz @ 1 Hz)
32 different alarm sounds (adjustable via DIP-switch)
Up to 3 tones can be activated externally to realize different signals
Sound pressure level reduction with potentiometer by up to 15 dB (A)
Operation in hazardous areas from 10 to 28 V DC supply via a Zener barrier or galvanic isolation
Shock-resistant housing
Suitable for outdoor use
Categories 1G, 2G and 3G (zones 0,1 and 2)
Operation voltage 24 V DC
Volume Max. 112 dB +/- 3 dB
Ambient temperature -40°C up to +60°C
Humidity 90% at +50°C
Protection class IP 65
Colour housing Flame red, similiar to RAL 3000
Material ABS, self-extinguishing similar UL 94 VO
Dimensions (H x W X D) 135mm x 130mm x 130mm
Weight 0,75 kg
ATEX-No. 04ATEX2301X, II1GEExiaIICT4
Standards DIN EN 50020
General remarks The EX sounder operates only directly at the signal line outputs of the
detect 3004 and detect 3016 and at the SC8-card (Art.-no. 30118).
Within an ATEX-area the Zenerbarrier Z728 (Art.-no. 32307) is required.
Technical data
Properties:
Ex zone 0, 1 or 2; Categories 1G, 2G or 3G, Temperature class T4
Mounting option for 35 mm DIN rail according to DIN EN 50022
Self-opening clamps, max wire dimension 2 x 2,5 mm²
Operation voltage 24 V DC
Ambient temperature -20°C up to +60°C
Colour housing Green
Material ABS
ATEX-No. BAS01ATEX7005X
20. Ex-proof components and accessories 147
Technical data
Properties:
For explosive areas Group II, category 2GD (Zones 1,2,21&22)
No ex-barrier required
Dust and water proof housing with IP 66
Thin colourless front glass easy to replace
Operation current: nominal current = 0,1 A; Short circuit current = 4,5 A
Connecting terminal: 0,08-2,5 mm²
Cable entry: 2 x M20 x 1,5 (Ø 6-12 mm)
Type of protection: II2G Ex emb IIC T6, II2D Ex tD A21 IP6X T80°C
Scope of supply: Manual Call point, 2 screws, 2 wall anchors, 1 blind plug (M20 x 1,5)
Operation voltage 12 to 28 V DC
Ambient temperature -20°C up to +60°C
Protection class IP 66
Colour housing Red
Material ABS
Dimensions (H x W x D) 145mm x 135mm x 71mm
Weight 0,5 kg
ATEX BAS02, ATEX 1729
EX-beacon red
Art.-no. 31222 - Type BE 24 R Eex
EX-beacon yellow
Art.-no. 31223 - Type BE 24 Y Eex
Description:
Red (Art.-no. 31222) or yellow (Art.-no. 31223) Beacon for
conventional systems in Ex-proof design for hazardous
areas
red version
Technical data
Properties:
Yellow aluminium housing and red (Art.-no. 31222) or yellow (Art.-no. 31223) calotte
High light performance
Stainless steel protection for the calotte
Flash energy: 15 Joule
Operation voltage 24 V DC
Alarm / operation current 1,0 A
Ambient temperature -20°C to +40°C
Colour housing Yellow
Material Aluminium
Dimensions (H x Ø) 243 mm x 110 mm
Weight 2,1 kg
ATEX II 2G Eex de IIC T6
21. Linear heat detectors and accessories 148
Technical data
Properties:
Application e.g.: garages, tunnels, parking houses, escalator, conveyors, cable ducts,
cold store, high voltage plants, recycling plants etc.
For the connection of up to 300 m sensor cable
Connection of cables being resistant against mechanical, chemical and biological influences
Adjustment of the sensitivity of the linear heat cable detector via 16 stage DIP-switch
with free adjustment of fiexed and rate of rise temperature
Three potential free relays contacts for the connection to the fire control panel
via IOM 3311 module, 2 alarm relays, 1 fault relay
Monitoring of wire break and short circuit
Test key for simultation, alarm, fault and LED test
Connection to the loop 3000 via IOM 3311
Suitable for detection in classes A1, A2, B and C
Suitable for the use in Ex zones (Zone 1 and Zone 2; Zone 21 and Zone 22)
Operation voltage 10 to 30 V DC
Quiescent current 28 mA (at 24 V)
Potential free relays 2 x 30 V / 1 A DC
Ambient temperature -25°C to 50°C
Protection class IP 65
Colour housing Grey (similar to RAL 7035)
Dimensions (H x W x D) 105 mm x 105 mm x 65 mm
Weigth 0,37 kg
Fastening clamp
Art.-no. 31620 - Type SK-LS
Description:
Fastening clamp for an easy fast mounting of the sensor
cable
Technical data
Properties:
Suitable for cables up to 6 mm
Packing unit: 100 pieces
21. Linear heat detectors and accessories 149
Technical data
Properties:
Not for outdoor use; limited resistanc against UV-light
Diameter 3,15 mm
Tensile strength 100 N
Technical data
Properties:
Suitable for the outdoor use
UV-resistant
Sensorcable with nylon cover
Diameter 4,8 mm
Tensile strength 100 N +
Technical data
Properties:
Application e.g.: garages, tunnels, parking houses, escalator, conveyors, cable ducts,
cold store, high voltage plants, recycling plants etc.
For the connection of up to 300 m sensor cable
Connection of cables being resistant against mechanical, chemical and biological influences
External 24 V supply required
Potential free alarm and fault output
Connection to the loop3000 via IOM 3311
Monitoring of wire break and short circuit
Operation voltage 24 V DC
Quiescent current 28 mA
Potential free relays 2 x 30 V / 1 A DC
Ambient temperature -25°C to 50°C
Protection class IP 65
Colour housing Grey / White
Dimensions (H x W x D) 110 mm x 110 mm x 66 mm
Weigth 0,27 kg
Technical data
Properties:
Integrated LC-Display with 2x16 characters, arrow keys control panel
Integrated automatic adjustment of the detector to the ambient conditions
via intelligent teach in modes
Intelligent laser sensor technology with consideration of ambient conditions for fast detection
in difficult environments
Highest reliability by optimal adjustment of the alarm threshold via intelligent algorithm
for the fire detection
Unwanted alarms from dust are avoided using patented Dual Technology LDD 3D3,
Laser dust discrimination and elimination system
Automatic day-/night mode for the adjustment from and to temporally different ambient conditions
Integrated fast learn for the automatic configuration of the system
Special integrated technology for the elimination of influences by pollution (dust etc.)
Integrated dust filter
4 sampling pipes, up to 250m maxium length:
- Total pipe lenght 200m with up to 100 sampling holes
- Total pipe lenght 250m with up to 80 sampling holes
1 recirculation pipe for the compensation of the intrasystem pressure gradient
Integrated RS485-interface for the network of up to 127 participants
Integrated potential free relays outputs for alarm and fault
External voltage supply required
Functions completely integrated via loop3000 protocol
Operation voltage 21,6 - 26,4 V DC
Current supply 450 mA at 24 V DC at fan speed 8
Outputs 5 potential free relays for info, pre-alarm, fire 1, fire 2, fault
Particle sensitivity range 0,0003 µm to 10 µm
Ambient temperature -10°C to +60°C
Humidity Max. 90 % (non-condensing)
Protection class IP 50
Pipe diameter 3/4"
Colour housing Light grey
Material Cast aluminium/ABS
Dimensions (H x W x D) 372 mm x 427 mm x 95 mm
Weight 5,2 kg
VdS approval G203024
System approval S295054 and S208123
Standards DIN EN 54-20
General remarks Software for the design of projects available on request
22. Smoke Aspiration Systems and accessories 152
Technical data
Properties:
Integrated LC-Display with 2x16 characters, arrow keys control panel
External voltage supply required
Integrated RS485-interface for the network of up to 127 participants
Integrated potential free relays outputs for alarm and fault
Operation voltage 21,6 - 26,4 V DC
Current supply 250 mA at 24 V DC
Ambient temperature -10°C to +60°C
Humidity Max. 90 % (non-condensing)
Protection class IP 50
Colour housing Light grey
Material Cast aluminium/ABS
Dimensions (H x W x D) 372 mm x 427 mm x 95 mm
Weight 5,2 kg
VdS approval G203024
System approval S295054 and S208123
Standards DIN EN 54-20
General remarks Software for the design of projects available on request
Technical data
Properties:
Integrated automatic adjustment of the detector to the ambient conditions
via intelligent teach in modes
Intelligent laser sensor technology with consideration of ambient conditions for fast detection
in difficult environments
Highest reliability by optimal adjustment of the alarm threshold via intelligent algorithm
for the fire detection
Unwanted alarms from dust are avoided using patented Dual Technology LDD 3D3,
Laser dust discrimination and elimination system
Automatic day-/night mode for the adjustment from and to temporally different ambient conditions
Integrated fast learn for the automatic configuration of the system
Special integrated technology for the elimination of influences by pollution (dust etc.)
Integrated dust filter
2 sampling pipes, up to 100 m maxium length:
- Total pipe lenght 100 m with up to 25 sampling holes
- Total pipe lenght 2 x 50 m with up to 25 sampling holes
1 recirculation pipe for the compensation of the intrasystem pressure gradient
Integrated RS485-interface for the network of up to 127 participants
External voltage supply required
Functions completely integrated via loop3000 protocol
Including mounting base and connection flange for the recirculation pipe
Operation voltage 21,6 - 26,4 V DC
Current supply 400 mA at 24 V DC
Measurement range Measurement range (%Obs/m) 0,03% to 25%
Particle sensitivity range 0,0003 µm to 10 µm
Ambient temperature -10°C to +60°C
Humidity Max. 90 % (non-condensing)
Protection class IP 50
Pipe diameter 3/4"
Colour housing Light grey
Material Cast aluminium/ABS
Dimensions (H x W x D) 200 mm x 293 mm x 83 mm
Weight 3,7 kg
Standards DIN EN 54-20
General remarks Software for the design of projects available on request
Accessories Relays-board (Art.-no. 32236) with 5 potential free relays outputs
22. Smoke Aspiration Systems and accessories 154
Technical data
Properties:
Integrated automatic adjustment of the detector to the ambient conditions
via intelligent teach in modes
Intelligent laser sensor technology with consideration of ambient conditions for fast detection
in difficult environments
Highest reliability by optimal adjustment of the alarm threshold via intelligent algorithm
for the fire detection
Unwanted alarms from dust are avoided using patented Dual Technology LDD 3D3,
Laser dust discrimination and elimination system
Automatic day-/night mode for the adjustment from and to temporally different ambient conditions
Integrated fast learn for the automatic configuration of the system
Special integrated technology for the elimination of influences by pollution (dust etc.)
Integrated dust filter
2 sampling pipes, up to 50 m maxium length:
- Total pipe lenght 50 m with up to 10 sampling holes (25 m at highest sensitivity)
1 recirculation pipe for the compensation of the intrasystem pressure gradient
Integrated RS485-interface for the network of up to 127 participants
External voltage supply required
Functions completely integrated via loop3000 protocol
Including mounting base and connection flange for the recirculation pipe
Operation voltage 21,6 - 26,4 V DC
Current supply 250 mA at 24 V DC
Measurement range Measurement range (%Obs/m) 0,03% to 25%
Particle sensitivity range 0,0003 µm to 10 µm
Ambient temperature -10°C to +60°C
Humidity Max. 90 % (non-condensing)
Protection class IP 50
Pipe diameter 3/4"
Colour housing Light grey
Material Cast aluminium/ABS
Dimensions (H x W x D) 175 mm x 135 mm x 83 mm
Weight 1,01 kg
VdS approval G207078
System approval S295054 and S208123
Standards DIN EN 54-20
General remarks Software for the design of projects available on request
Accessories Relays-board (Art.-no. 32236) with 5 potential free relays outputs
22. Smoke Aspiration Systems and accessories 155
Relay board
Art.-no. 32236 - Type REC
Description:
Relays board for the connection of the smoke aspiration
detector to a fire control panel
Technical data
Properties:
5 potential free relays for the connection to a fire control panel
(2 x alarm, 1 x pre-alarm, 1 x info-alarm, 1 x fault)
3 free Inputs for the programming of functions like e.g.
- Reset of the detector,
- Reduction of the detector sensitivity,
- Indication for the battery capacity
Mounting as plug in module on the main board
Compatible to all Micra smoke aspiration detectors
Ambient temperature -10°C to +60°C
Outputs 5 relays contacts 0,4 A / 24 V
Dimensions (H x W x D) 68 mm x 100 mm x 25 mm
Technical data
Properties:
Compatible to HSSD-2 and Micra smoke aspiration detectors
Integrated self regulating heating element 60-200W
4 rearward and 2 below placed pipe holes
Protected ceramic terminal block and cable entries
Ambient temperature -10°C to +60°C
Heater 230V 60-200W
Dimensions (H x W x D) 264 mm x 140 mm x 160 mm
Pipe diameter 3/4"
Material Sheet steel, zinc-plated
General remarks Recommended use with HSSD-2
Temperature control of the aspirated aistream available upon request
Pipe
Art.-no. 31133 - Type AR
Description:
Non-halogen pipe for all smoke aspiration detectors from
the series HSSD-2 and Micra range
Dimensions ( Ø x L) 3/4" / 27 mm x 62 mm
Bend 90°
Art.-no. 31136 - Type B90
Description:
Bend 90° for the non halogen pipe for all smoke aspiration
detectors from the series HSSD-2 and Micra range
Dimensions ( Ø x L x D) 3/4" / 27 mm x 65 mm x 50
For more technical details please see next page.
22. Smoke Aspiration Systems and accessories 158
Screw joint
Art.-no. 31141 - Type VG
Description:
Screw joint for the non halogen pipe for all smoke
aspiration detectors from the series HSSD-2 and Micra
range for creation of connection holes for the cleaning and
blowing out of the installed pipe system
Dimensions ( Ø x L) 3/4" / 27 mm x 53 mm
End cap
Art.-no. 31143 - Type EK
Description:
End cap for the non halogen pipe for all smoke aspiration
detectors from the series HSSD-2 and Micra range
Dimensions ( Ø x L) 3/4" / 27 mm x 30 mm
Reducer adapter
Art.-no. 31150 - Type RA
Description:
Reducer for the non halogen pipe for all smoke aspiration
detectors from the series HSSD-2 and Micra range to suit
25mm DIN nominal size
Technical data for 3/4" pipe system (page 157 and 158)
Properties:
Low coefficient of thermal expansion extension due to the special ABS version
High flexibility and bending properties
Resistant against strong mechanical loads
High resistance against chemicals and aggressive ambient conditions
Pipe diameter 3/4"
Colour Red
Material ABS, non-halogen
Accessories Fastening clip (Art.no. 31145) for pipe
Special adhesive (Art.-no. 31147)
ABS-detergent (Art.-no. 31148)
General remarks No electrostatic charging
The pipe system has to be securely fixed at all junctions.
All sampling holes have to be drilled in accordance to the guidelines
of the systems vendor and have to be marked with warning labels.
22. Smoke Aspiration Systems and accessories 159
Technical data
Properties:
For an easy fixation of pipes
Low coefficient of thermal expansion extension due to the special ABS version
Resistant against strong mechanical loads
High resistance against chemicals and aggressive ambient conditions
Pipe diameter 3/4"
Colour Red
Material ABS, non-halogen
Dimensions (H x W x D) 55 mm x 45 mm x 20 mm
Accessories Suspension 60mm (Art-no. 31146)
Flange nut (Art.-no. 31960)
Suspension for mounting clip
Art.-no. 31146 - Type AB
Description:
Suspension for the mounting clip for the non halogen pipe
for all smoke aspiration detectors from the series HSSD-2
and Micra range for the fixation of mounting clips on
uneven surfaces.
Technical data
Properties:
For the adjustment of uneven surfaces and suspension of the pipe
Distance up to 60 mm
Colour Grey
Material Steel
Dimensions ( L) Max. 115 mm
Accessories Flange nut (Art.-no. 31960)
Flange nut for mounting clip
Art.-no. 31960 - Type FM
Description:
Flange nut for the mounting clip for pipes onto the
suspension
Technical data
Properties:
Enables the direct assembly of the mounting clip for pipes onto the suspension threaded pin
Size M8
Colour Grey
Material Steel
Dimensions (H x W x D) 20 mm x 10 mm x 2 mm
22. Smoke Aspiration Systems and accessories 160
T-hose pipe-adapter
Art.-no. 31153 - Type TKA
Description:
Adapter for the connection of a hose pipe to the non
halogen pipe system for all smoke aspiration detectors
from the series HSSD-2 and Micra range.
The aspirating holes can be placed 8m away with the hose
pipe.
T-piece for connection of 10mm hose pipe
Dimensions ( Ø x L x T) 3/4" / 27 mm x 41 mm x 58 mm
Colour Red
Hose pipe, white
Art.-no. 31152 - Type KW
Description:
Hose pipe for the out of line place of an aspirating hole for
the non halogen pipe system for all smoke aspiration
detectors from the series HSSD-2 and Micra range.
The aspirating holes can be placed 8m away with the hose
pipe.
Colour White
Plug in piece
Art.-no. 31613 - Type SK
Description:
Plug in piece for the connection of the 10 mm hose pipe
attached to the non halogen pipe for all smoke aspiration
detectors from the series HSSD-2 and Micra range
Dimensions ( Ø x L) 10 mm x 20 mm
Colour White
Dimensions ( Ø x L) 65 mm x 40 mm
End piece for hose pipe
Art.-no. 31155 - Type KK
Description:
End piece with clamp fastening for connection to the 10
mm hose pipe attached to the non halogen pipe for all
smoke aspiration detectors from the series HSSD-2 and
Micra range
Dimensions ( Ø x L) 33 mm x 73 mm
Technical data for FK and KK
Pipe diameter 10mm
Colour White
Material ABS, non-halogen
Accessories Special adhesive (Art.-no. 31147)
ABS-detergent (Art.-no. 31148)
Smoke pen
Art.-no. 32334 - Type RS
Description:
Smoke pen for the test and function control suitable for all
Including 6 smoke cartridges
smoke aspiration detectors of the series HSSD-2 and
Micra
Smoke generator
Art.-no. 31539 - Type AX 18
Description:
Including 5 smoke cartridges
Pyroctechnical smoke generator for the funtion test for all
Smoking time per cartridge: approx. 4 min
smoke aspiration detectors from the series HSSD-2 and
Smoke volume per cartridge: approx. 17 m³
Micra range
23. Voice Evacuation System - Sound detect 163
System controller Pantura 622 LFO, Fibre optic interface for network
Art.-no. 32408 - Type SD-PCT 622 LFO
Description:
PCT 622 LFO system control unit for the Pantura EVAC-
system for the management of up to 6 paging stations and
2 audio-inputs and 2 audio outputs with an integrated fibre
optic interface
Integrated audio matrix with 6 connections for paging stations, 2 audio inputs for external auxiliaries
and 2 audio outputs for the processing in the speaker matrix
Networking via redundant optical cable ring
Output level Line-Out +6 to +8dBu
Weight Approx. 3,7 kg
System controller Pantura 1244 LFO, Fibre optic interface for network
Art.-no. 32410 - Type SD-PCT 1244 LFO
Description:
PCT 1244 LFO system control unit for the Pantura EVAC-
system for the management of up to 12 paging stations
and 4 audio-inputs and 4 audio-outputs with an integrated
fibre optic interface for an optional redundant Network
(Loop) with a second system controller
Integrated audio matrix with 12 connections for paging stations, 4 audio inputs for external auxiliaries
and 4 audio outputs for the processing in the speaker matrix
Networking via redundant optical cable ring
Output level Line-Out Optical (50 or 62,5 µm): ca. 2000 m
Weight Approx. 4,2 kg
For more technical details please see next page.
23. Voice Evacuation System - Sound detect 164
Technical data
Properties:
Signal distribution matrix (100 V) with 4 independent signal inputs
8 line-relais / 8 signal outputs per signal input allowing 32 signal outputs / speaker lines
Integrated multichannel unit for the distribution of signals to the speaker lines.
4 simultaneous audio signals will be distributed to 8 speaker lines;
2 simultaneous audio signals will be distributed to 16 speaker lines;
1audio signal will be distributed to 32 speaker lines
Entire management and control by the system controler SD-PCT via data bus P-DATA
Integrated emergency switch via external activation of the line relais
Permanent monitoring of all amplifiers/ amplifier signals and automatic adjustment
of the signal routing at amplifier fault
Dedicated spare amplifier in single channel systems
Intelligent amplifier operation according to power requirement
Permanent monitoring of broken wire, short-cicuit and ground fault of all speaker lines
Impedance measurement by 20kHz pilot tone
Non reactive switch off of short-circuit speaker lines
Max. 30 speaker matrix per system controller
Shallow design (1HE) and 19"-fitting
Factory provided serial number for addressing in the system
Operation voltage 18 to 36 V DC
Input voltage differential 0 to 100 V RMS; 0 to 141 V Pk
Input current amplifier 0,05 to 7 A RMS; 0,07 to 10 A Pk
Output current conductor 0,05 to 7 A RMS; 0,07 to 10 A Pk
Measurement ground fault resistance 0 to 550 KOhm
Input voltage LOW UDATA + - UDATA - -7 to -0,2 V
Input voltage HIGH UDATA + - UDATA - 0,2 to 12 V
Input current -7V < UIn < + 12 V -0,15 to 0,25 mA
Input current -60V < UIn < + 60 V -6 to 6 mA
Output voltage
[UDATA + - UDATA -], RL = 54 Ohm Min. 1,5 V
Slew rate
CL = 50pF per wire to Common,
RL = 54 Ohm (Data+ to Data-) 0,2 to 2 µs
Bus load Max. 0,5 UL
Power consumption Max. 21 W
Humidity 90%, non-condensing
Mounting 19"-fitting
Colour housing Silver grey
Material Metal
Dimensions (H, W, D) 44,4 mm (1HE) x 483 mm (19") x 240 mm
Weight Approx. 3,85 kg
23. Voice Evacuation System - Sound detect 166
Technical data
Properties:
Each optocoupler-input can be individually configurated as voltage input or as
input for a potential free contact
Wide input voltage range
All inputs are protected against reverse polarity by integrated inverse-polarity protection
Supply voltage 12 to 36 V DC
Current consumption Max. 20 mA
Optocoupler input current
(Ue = 5…36V) 6 mA
Input voltage optocoupler HIGH 5 to 36 V DC
Input voltage optocoupler LOW 0 to 0,7 V DC
Humidity 90%, non-condensing
Connection Bus participant
Colour housing Black
Material ABS
Dimensions (H x W x D) Approx. 35 mm x 98 mm x 88 mm
Weight Approx. 0,13 kg
23. Voice Evacuation System - Sound detect 169
Technical data
Properties:
Each relay can be individually configured as closed (NO) or open dry contact (NC).
With common power inlet on UEXT each relay can be individually set to
normally open contact voltage output (NO) or normally closed contact voltage output (NC)
Supply voltage 18 to 36 V DC
Current consumption UB = 18 V, no load: 33mA
UB =18 V, all relays operated: 110 mA
UB = 36 V, no load: 35 mA
UB = 36 V, all relays operated; 65 mA
Relay switching voltage 48 V
Relay switching current 6,5 A
Humidity 90%, non-condensing
Connection Bus particpant
Colour housing Black
Material ABS
Dimensions (H x W x D) Approx. 35 mm x 98 mm x 88 mm
Weight Approx. 0,16 kg
23. Voice Evacuation System - Sound detect 170
Technical data
Properties:
Connection of external loads via switching outputs (Lx)
All switching outputs are short-circuit-proof against the positve and the negative wire supply
Isolated voltage supply of the switching outputs and the bus supply
Input wiring is possible via potential free contacts
or alternatively via (NPN ) transistor output of an op-coupler
Supply voltage 12 to 36 V DC
Supply voltage outputs 9 to 25 V DC
Current consumption Max. 30 mA
Current consumption output driver Open load = 24 mA, allowable full load = 2,1 A
Load current (per output) 350 mA
Humidity 90%, non-condensing
Connection Bus participant
Colour housing Black
Material ABS
Dimensions (H x W x D) Approx. 35 mm x 98 mm x 88 mm
Weight Approx. 0,13 kg
23. Voice Evacuation System - Sound detect 171
Technical data
Properties:
Spring clamps for a fast, reliable and easy mounting.
Shock resistant housing for the use in difficult environments
UV-resistant colour
Different colours available on request
Power 6/3/1,5 W
Frequency range 64-19.385 Hz
Sound pressure level SPL 1W/1m 94,9 dB
Sound pressure level SPL Pmax/1m 105,3 dB
Ceiling cut-out 170 mm
Dispersion angle (-10dB) 180° (H) / 180° (V)
Mounting Spring clamps
Connection Plug-in connection
Colour housing RAL 9010 white
Material Metal
Dimensions 200 mm x 65 mm
Weight 0,875 kg
23. Voice Evacuation System - Sound detect 172
Technical data
Properties:
Suitable for the installation in a fire dome to avoid the stack effect at suspended ceilings.
No smoke/ fire will be passing above suspended ceiling in case that
the speaker membrane is burned.
Spring clamps for a fast, reliable and easy mounting.
Shock resistant housing for the use in difficult environments
UV-resistant colour
Different colours available on request
Power 6/3/1,5 W
Frequency range 100-16.000 Hz
Sound pressure level SPL 1W/1m 97,9 dB
Sound pressure level SPL Pmax/1m 105,7 dB
Ceiling cut-out 197 mm
Ambient temperature -20°C to +80°C
Dispersion angle (-10dB) 180° (H) / 180° (V)
Mounting Spring clamps
Connection Plug-in connection
Colour housing RAL 9010 white
Material Metal
Dimensions 220 mm x 100 mm
Weight 1,3 kg
23. Voice Evacuation System - Sound detect 173
Ceiling speaker, powder coated metal, deep version, 165 mm speaker incl. fire dome, BS 5839
Art.-no. 32393 - Type SD-DL 06-165/T BS 5839
Description:
Ceiling speaker in elegant design with 165mm full range
speaker for a high efficiency and excellent sound in all
fields of application according to British Standard BS 5839
part 8
Technical data
Properties:
Equipped with ceramic terminal, thermo fuse and a temperature resistant cable
to ensure an increased safety in case of fire
Including fire dome to avoid the stack effect at suspended ceilings. No smoke/ fire will
be passing above suspended ceiling in case that the speaker mebrane is burned.
Spring clamps for a fast, reliable and easy mounting.
Shock resistant housing for the use in difficult environments
UV-resistant colour
Different colours available on request
Power 6/3/1,5 W
Frequency range 100-16.000 Hz
Sound pressure level SPL 1W/1m 97,9 dB
Sound pressure level SPL Pmax/1m 105,7 dB
Ceiling cut-out 197 mm
Ambient temperature -20°C to +80°C
Dispersion angle (-10dB) 180° (H) / 180° (V)
Mounting Spring clamps
Connection Plug-in connection
Colour housing RAL 9010 white (fire dome - black)
Material Metal
Dimensions speaker 220 mm x 100 mm
Dimensions fire dome 162 mm x 61 mm
Weight speaker + fire dome 1,6 kg
General remarks The fire dome can not be used as built in dome for concrete ceilings.
23. Voice Evacuation System - Sound detect 174
Technical data
Properties:
Shock resistant and ball proof housing (according to DIN 18032 part 3)
for the use in difficult environments
Certified fire protection class B2 accord. to DIN 4102, part 8 of the building part test
and DIN 4102, part 1 of the B2-test for building material
Suitable for the installation in a fire dome to avoid the stack effect at suspended ceilings. No
smoke/ fire will be passing above suspended ceiling in case that the speaker mebrane is burned.
Spring clamps for a fast, reliable and easy mounting.
UV-resistant colour
Different colours available on request
Power 6/3/1,5 W
Frequency range 200-16.000 Hz
Sound pressure level SPL 1W/1m 96,9 dB
Sound pressure level SPL Pmax/1m 104,7 dB
Ceiling cut-out 200 mm
Ambient temperature -20°C to +150 °C
Dispersion angle (-10dB) 180° (H) / 180° (V)
Mounting Spring clamps
Connection Plug-in connection
Colour housing RAL 9010 white
Material Metal
Dimensions 232 mm x 63 mm
Weight 1,05 kg
General remarks The fire dome is not included in the delivery.
23. Voice Evacuation System - Sound detect 175
Ceiling speaker, ball proofed, 165 mm speaker, incl. fire dome, BS 5839
Art.-no. 32394 - Type SD-DL-FF 06-165/T BS 5839
Description:
Ceiling speaker in elegant design with 165mm full range
speaker for a high efficiency and excellent sound in all
fields of application suitable for the installation in a fire
dome, built in dome for concrete ceilings or
electroacoustical housing according to British Standard BS
5839 part 8
Technical data
Properties:
Equipped with ceramic terminal, thermo fuse and a temperature resistant cable to ensure
an increased safety in case of fire
Shock resistant and ball proof housing (according to DIN 18032 part 3)
for the use in difficult environments
Certified fire protection class B2 accord. to DIN 4102, part 8 of the building part test
and DIN 4102, part 1 of the B2-test for building material
Including fire dome to avoid the stack effect at suspended ceilings. No
smoke/ fire will be passing above suspended ceiling in case that the speaker mebrane is burned.
Spring clamps for a fast, reliable and easy mounting.
UV-resistant colour
Different colours available on request
Power 6/3/1,5 W
Frequency range 200-16.000 Hz
Sound pressure level SPL 1W/1m 96,9 dB
Sound pressure level SPL Pmax/1m 104,7 dB
Ceiling cut-out 200 mm
Ambient temperature -20°C to +150 °C
Dispersion angle (-10dB) 180° (H) / 180° (V)
Mounting Spring clamps
Connection Plug-in connection
Colour housing RAL 9010 white
Material Metal
Dimensions 232 mm x 104 mm
Weight 1,79 kg
23. Voice Evacuation System - Sound detect 176
Ceiling speaker, powder coated metal, ball proofed, 200 mm speaker, excl. fire dome
Art.-no. 32539 - Type SD-DL 10-200/T
Description:
Ceiling speaker in elegant design with 200 mm full range
speaker for a high efficiency and excellent sound in all
fields of application
Technical data
Properties:
Shock resistant and ball proof housing (according to DIN 18032 part 3)
for the use in difficult environments
Certified fire protection class B2 accord. to DIN 4102, part 8 of the building part test
and DIN 4102, part 1 of the B2-test for building material
Suitable for the installation in a fire dome to avoid the stack effect at suspended ceilings. No
smoke/ fire will be passing above suspended ceiling in case that the speaker mebrane is burned.
Spring clamps for a fast, reliable and easy mounting.
UV-resistant colour
Different colours available on request
Power 10/6/3/1,5 W
Frequency range 100-19.000 Hz
Sound pressure level SPL 1W/1m 94,5 dB
Sound pressure level SPL Pmax/1m 104,5 dB
Ceiling cut-out 238 mm
Ambient temperature -20°C to +80 °C
Dispersion angle (-10dB) 178° (H) / 178° (V)
Mounting Spring clamps
Connection Plug-in connection
Colour housing RAL 9010 white
Material Metal
Dimensions 267 mm x 100 mm
Weight 1,8 kg
General remarks The fire dome is not included in the delivery.
23. Voice Evacuation System - Sound detect 177
Ceiling speaker, powder coated metal, ball proofed, 200 mm speaker, incl. fire dome, BS 5839
Art.-no. 32395 - Type SD-DL 10-200/T BS 5839
Description:
Ceiling speaker in elegant design with 200 mm full range
speaker for a high efficiency and excellent sound in all
fields of application suitable for the installation in a fire
dome, built in dome for concrete ceilings or
electroacoustical housing according to British Standard BS
5839 part 8
Technical data
Properties:
Equipped with ceramic terminal, thermo fuse and a temperature resistant cable to ensure
an increased safety in case of fire
Including fire dome to avoid the stack effect at suspended ceilings. No
smoke/ fire will be passing above suspended ceiling in case that the speaker mebrane is burned.
Shock resistant and ball proof housing (according to DIN 18032 part 3)
for the use in difficult environments
Certified fire protection class B2 accord. to DIN 4102, part 8 of the building part test
and DIN 4102, part 1 of the B2-test for building material
Suitable for the installation in a fire dome to avoid the stack effect at suspended ceilings. No
smoke/ fire will be passing above suspended ceiling in case that the speaker mebrane is burned.
Spring clamps for a fast, reliable and easy mounting.
UV-resistant colour
Different colours available on request
Power 10/6/3/1,5 W
Frequency range 100-19.000 Hz
Sound pressure level SPL 1W/1m 94,5 dB
Sound pressure level SPL Pmax/1m 104,5 dB
Ceiling cut-out 238 mm
Ambient temperature -20°C to +80 °C
Dispersion angle (-10dB) 178° (H) / 178° (V)
Mounting Spring clamps
Connection Plug-in connection
Colour housing RAL 9010 white
Material Metal
Dimensions speaker 267 mm x 100 mm
Dimensions fire dome 267 mm x 100 mm
Weight 2,37 kg
General remarks The fire dome can not be used as built in dome for concrete ceilings.
23. Voice Evacuation System - Sound detect 178
Technical data
Properties:
High-quality metal housing, easy to install, with white metal mounting frame
and a front cover with fine perforation for high sound transmission
Suitable for the installation in a fire dome to avoid the stack effect at suspended ceilings.
No smoke/ fire will be passing above suspended ceiling in case that
the speaker membrane is burned.
Spring clamps for a fast, reliable and easy mounting.
Shock resistant housing for the use in difficult environments
UV-resistant colour
Different colours available on request
Power 6/3/1,5 W
Frequency range 149-18.896 Hz
Sound pressure level SPL 1W/1m 94,5 dB
Sound pressure level SPL Pmax/1m 110,0 dB
Ceiling cut-out 215 mm
Ambient temperature -20°C to +150°C
Dispersion angle (-10dB) 180° (H) / 180° (V)
Mounting Spring clamps
Connection Plug-in connection
Colour housing RAL 9010 white
Material Metal
Dimensions 245 mm x 65 mm
Weight 1,5 kg
General remarks The additional available fire dome can not be used as built in dome
for concrete ceilings.
23. Voice Evacuation System - Sound detect 179
Technical data
Properties:
Equipped with ceramic terminal, thermo fuse and a temperature resistant cable to ensure
an increased safety in case of fire
Shock resistant and ball proof housing (according to DIN 18032 part 3)
for the use in difficult environments
Certified fire protection class B2 accord. to DIN 4102, part 8 of the building part test
and DIN 4102, part 1 of the B2-test for building material
Suitable for the installation in a fire dome to avoid the stack effect at suspended ceilings. No
smoke/ fire will be passing above suspended ceiling in case that the speaker mebrane is burned.
Spring clamps for a fast, reliable and easy mounting.
UV-resistant colour
Different colours available on request
Power 10/6/3/1,5 W
Frequency range 200-17.400 Hz
Sound pressure level SPL 1W/1m 95,9 dB
Sound pressure level SPL Pmax/1m 108,7 dB
Ambient temperature -20°C to +80 °C
Dispersion angle (-10dB) 180°
Mounting Screws
Colour housing RAL 9010 white
Material Metal
Dimensions 210 mm x 80 mm
Weight 1,69 kg
23. Voice Evacuation System - Sound detect 180
Equipped with ceramic terminal, thermo fuse and a temperature resistant cable to ensure
an increased safety in case of fire
Technical data
Properties:
Shock resistant housing for the use in difficult environments
UV-resistant colour
Spring clamps on the rear plate for a fast, reliable and easy mounting.
Power 6/3/1,5 W
Frequency range 125-15.000 Hz
Sound pressure level SPL 1W/1m 97,5 dB
Sound pressure level SPL Pmax/1m 105,3 dB
Ambient temperature -20°C to +150 °C
Dispersion angle (-10dB) 180° (H) / 180° (V)
Protection class IP 54
Mounting Screws/Spring clamps
Connection Plug-in connection
Colour housing White
Material MDF-wood
Dimensions 252 mm x 192 mm x 82 mm
Weight 1,8 kg
23. Voice Evacuation System - Sound detect 181
Technical data
Properties:
Shock resistant housing for the use in difficult environments
UV-resistant colour
Spring clamps on the rear plate for a fast, reliable and easy mounting.
Power 2 x 6/3/1,5 W
Frequency range 230-18.379 Hz
Sound pressure level SPL 1W/1m 97,8 dB
Sound pressure level SPL Pmax/1m 112,8 dB
Protection class IP 54
Ambient temperature -20°C to +120 °C
Dispersion angle (-10dB) 150° (H) / 150° (V)
Mounting Screws/Spring clamps
Connection Plug-in connection
Colour housing White
Material MDF-wood
Weight 2,1 kg
23. Voice Evacuation System - Sound detect 182
Technical data
Properties:
Equipped with ceramic terminal, thermo fuse and a temperature resistant cable to ensure
an increased safety in case of fire
Shock resistant housing for the use in difficult environments
UV-resistant colour
Power 20/10/5/2,5 W
Frequency range 150-20.000 Hz
Sound pressure level SPL 1W/1m 99,5 dB
Sound pressure level SPL Pmax/1m 112,5 dB
Ambient temperature -20°C to +150 °C
Dispersion angle (-10dB) 360° (H) / 360° (V)
Mounting Mounting bracket
Connection 5-wire cable, length 1m
Colour housing RAL 9010 white
Material ABS-plastic
Dimensions 140 mm x 195 mm
Weight 1,35 in kg
23. Voice Evacuation System - Sound detect 183
Technical data
Properties:
Enormous sound pressure, high wheather-resistance and broad frequency range
for industrial use (workshops, outdoor use, swimming pools etc.)
Protection class IP 66 for reliability under challenging environments
Shock resistant ABS-housing accord. to UL 94-VO for enduring stability.
The rust-proof U-bracket made of V2A allowing a flexible and quick mounting
is included in the delivery
Flexible power adjustments (DK10: 20 Ohm) can easily be made on the back of the horn speaker.
Power 10 / 5 / 2,5 / 1,25 W
Frequency range 400-10.000 Hz
Sound pressure level SPL 1W/1m 102,4 dB
Sound pressure level SPL Pmax/1m 112,4 dB
Protection class IP 66
Ambient temperature -50°C to +100°C
Dispersion angle (-10dB) 140° (H) / 140° (V)
Mounting V2A-bracket
Connection 2-wire cable, lenght 1m
Colour housing RAL 7035 light grey
Material ABS-housing
Dimensions 142 mm x 210 mm
Weight 1,4 kg
23. Voice Evacuation System - Sound detect 184
Technical data
Properties:
Enormous sound pressure, high wheather-resistance and broad frequency range
for industrial use (workshops, outdoor use, swimming pools etc.)
Protection class IP 66 for reliability under challenging environments
Shock resistant ABS-housing accord. to UL 94-VO for enduring stability.
The rust-proof U-bracket made of V2A allowing a flexible and quick mounting
is included in the delivery
Flexible power adjustments (DK15: 20 Ohm) can easily be made on the back of the horn speaker.
Power 15 / 7,5 / 3,75 / 1,87 W
Frequency range 300-12.500 Hz
Sound pressure level SPL 1W/1m 107,3 dB
Sound pressure level SPL Pmax/1m 119,1 dB
Protection class IP 66
Ambient temperature -50°C to +100°C
Dispersion angle (-10dB) 140° (H) / 140° (V)
Mounting V2A-bracket
Connection 2-wire cable, lenght 1m
Colour housing RAL 7035 light grey
Material ABS-housing
Dimensions 208,5 mm x 271,5 mm
Weight 1,9 kg
23. Voice Evacuation System - Sound detect 185
Technical data
Properties:
Enormous sound pressure, high wheather-resistance and broad frequency range
for industrial use (workshops, outdoor use, swimming pools etc.)
Protection class IP 66 for reliability under challenging environments
Shock resistant ABS-housing accord. to UL 94-VO for enduring stability.
The rust-proof U-bracket made of V2A allowing a flexible and quick mounting
is included in the delivery
Flexible power adjustments (DK30: 20 Ohm) can easily be made on the back of the horn speaker.
Power 30/20/10/5 W
Frequency range 300-6.000 Hz
Sound pressure level SPL 1W/1m 110,1 dB
Sound pressure level SPL Pmax/1m 124,9 dB
Protection class IP 66
Ambient temperature -50°C to +100°C
Dispersion angle (-10dB) 130° (H) / 130° (V)
Mounting V2A-bracket
Connection 2-wire cable, lenght 1m
Colour housing RAL 7035 light grey
Material ABS-housing
Dimensions 238 mm x 302 mm
Weight 2,6 kg
23. Voice Evacuation System - Sound detect 186
Technical data
Properties:
The Rac-CD/MP3-Module (right module part) includes a programming function, a repeat mode,
a volume control and an auto-reverse-function
The unit comes with an USB-input and a SD-card reader and is compatible with CD, CD-R and MP3
The RAC-Tuner-Module (left module part) has an integrated 128MB Flash Memory
(120 min recording time), memory card reader (SD) up to 1GB, 2 microphone inputs (Chinch),
2 headphone jacks (chinch) and USB-Port (1.1)
The unit includes MP3 and WAV file management, 6 different repeat functions, level volume control,
recording volume control and supports digital MP3 recording with 44,1 KHz, 128 kbps
Driver software included, compatible to WIN98, WIN2000 and WIN XP
Shallow design and 19" fitting
Supply voltage 230 V AC , 50/60 Hz
Current consumption 45VA = 0,2A at 230 V AC; 0,9 A at 24 V DC
Ambient temperature 0°C to +40°C
Outputs Chinch-outputs (asymmetric) for each module, antenna terminal
Colour housing Black
Material Metal, ABS
Dimensions (H x W x D) Approx. 44 mm (1HE) x 483 mm (19") x 266 mm
Weight Approx. 4,5 kg
23. Voice Evacuation System - Sound detect 191
Technical data
Properties:
Integrated 6 W speaker with a 77mm full range speaker,
a 100 V-transformer and a wired potentiometer
Including programme selector for the selection of 6 different programme sources
The programm selector is equipped with a 24V priority override relay.
Shallow design (2HE) and 19" fitting
Power 6/3/1,5 W
Frequency range 70-17.000 Hz
Sound pressure level SPL 1W/1m 83,9 dB
Sound pressure level SPL Pmax/1m 91,7 dB
Dispersion angle (-10dB) 180°
Colour housing Black
Material Metal
Dimensions (H x W x D) Approx. 88 mm (2HE) x 483 mm (19") x 41 mm
Weight 1,3 kg
Technical data
Properties:
Selection of 6 different programme sources with a rotary switch
Integrated 24 V-priority override relay
Shallow design (2HE) and 19" fitting
Programme 6
Colour housing Pure white
Material ABS
Dimensions Approx. 81 mm x 81 mm x 56 mm
23. Voice Evacuation System - Sound detect 192
Suitable up to a power of 6 W
Dimensions Approx. 81 mm x 81 mm x 56 mm
Power 6W
Volume control uP, 12 Watt
Art.-no. 32569 - Type SD-LS 12 RUP
Description:
Volume control 12 Watt (in wall) for area volume control of
one speaker line (100 V)
Suitable up to a power of 12 W
Dimensions Approx. 81 mm x 81 mm x 56 mm
Power 12 W
Volume control uP, 50 Watt
Art.-no. 32570 - Type SD-LS 50 RUP
Description:
Volume control 50 Watt (in wall) for area volume control of
one speaker line (100 V)
Suitable up to a power of 50 W
Dimensions Approx. 81 mm x 81 mm x 74 mm
Power 50 W
Volume control uP, 100 Watt
Art.-no. 32571 - Type SD-LS 100 RUP
Description:
Volume control 100 Watt (in wall) for area volume control
of one speaker line (100 V)
Suitable up to a power of 6 W
Power (Volume control) 6W
Volume control-Programme selector combination, 12 Watt, 6 programmes
Art.-no. 32574 - Type SD-LS-PW 12 RUP
Description:
Volume control 12 W and programme selector
combination (in wall) for area volume control and
programme selection (up to 6 different programme
sources) for one speaker line (100 V)
Suitable up to a power of 12 W
Power (Volume control) 12 W
Technical data
Properties:
Volume control and programme selector including masking frame, plate and rotary switches,
colour pure white (GIRA STANDARD 55)
Volume control:
12-step continuously rotating attenuation switch with a zero position without remaining volume
Integrated 24 V-mandatory signalling relay
The volume control in »Fail to safe« version bridges the mandatory signalling relay
of the volume control in case that the voltage of the mandatory signal declines from 24 V to 0 V.
In this case the volume control is supplied with full power.
Programme selector:
Selection of 6 different Programme sources with a rotary switch
Integrated 24 V-priority override relay
Programmes (Programme selector) 6
Colour housing Pure white
Material ABS
Dimensions Approx. 81 mm x 81 mm x 56 mm
23. Voice Evacuation System - Sound detect 194
Technical data
Properties:
Including 18V phantom power by default for the SD - MI-VO
The phantom power can be disabled through the removal of two resistors
at the back of the circuit board
Microphone pre-amplifier including masking frame, plate,
rotary switch and XLR socket, colour pure white (GIRA STANDARD 55)
Operation voltage 18-30 V
Frequency range 40~20.000 Hz
Inputs 4,4 kOhm
Outputs 50 Ohm
Colour housing Pure white
Material ABS
Dimensions Approx. 81 mm x 81 mm x 45 mm
Weight 0,1 kg
Technical data
Properties:
Including 18V phantom power by default for the SD - MI-VO
Operation voltage 18-30 V
Frequency range 40~20.000 Hz
Inputs 50 kOhm
Outputs 50 Ohm
Colour housing Pure white
Material ABS
Dimensions Approx. 81 mm x 81 mm x 45 mm
Weight 0,1 kg
23. Voice Evacuation System - Sound detect 195
Mixer pre-amplifier
Art.-no. 32577 - Type SD-UP-MX 04
Description:
The flush mounted mixer pre-amplifier SD - UP-MX 04
combines a lot of features on a small spot for the use in
professional ELA acoustic irraduation equipment
Technical data
Properties:
The flush mounted mixer pre-amplifier comes with two icrophone and two line-inputs
(2 Cinch, 2 XLR) and an electonically balanced output with terminal connectors
High quality design with an aluminium anodise front plate with engraved inscription
Installation in tables, desks and furniture possible in flush mounted version
Seperate limiters for microphone channels and a phantom powering for
condenser microphones can be internally switched on
Matching built-in housing available on request
Operation voltage 22-30 V AC
Frequency range Mic: 150-20.000 Hz; AUX: 30-20.0000 Hz
Inputs Mic: -60dBu, AUX: -10dBu / 35 kOhm
Outputs +6dBu / 150 Ohm
Colour housing Alu anodised
Material Aluminium
Dimensions Approx. 205 mm x 150 mm x 40 mm
Weight 0,35 kg
23. Voice Evacuation System - Sound detect 196
Pre-amplifier, 8 channels
Art.-no. 32578 - Type SD-PRE-AMP 08
Description:
The 8 channel pre-amplifier SD-PRE-AMP 08 combines a
lot of features for the use in professional ELA acoustic
irraduation equipment
Technical data
Properties:
Equipped with 6 XLR-microphone inputs (switchable to LINE-operation)
and a channel for Tuner/AUX/CD
Including connectivity option to a phone system via seperate input
Three different priority settings for the signals can be easily set by jumpers for each individual project
Seperated limiters for microphone channels and a phantom powering for condenser microphones
can be internally switched on
Three different priorities are available:
- Serial mode: channel 1 has the highest priority, channel 7 the lowest
- Block before: The first activated channel gains the highest priority (channel 1-6)
- Block behind: The last activated channel gains the highest priority (channel 1-6)
Pre-amplifier including external power supply and 19“-mounting brackets
Including 24 V emergency power source connector
The number of channels can be extended from 8 to 16 by connection of
two SD- Pre-Amp 08 via a master/slave DIN socket
Including control input for the built in chime, which is masking the background music
Mains/ Battery voltage 24 V / 230 V AC 50 / 60Hz
24 V DC (MAX 10% deviation)
Frequency range 50~20.000 Hz +/-3dB
Inputs Mic (XLR, DIN): 1mV, 250ohm balanced; Line (XLR): 200mV, 47kOhm;
CD: 500mV, 47kOhm; Tuner: 200mV, 47kOhm; AUX: 200mV, 47kOhm;
Tel: 0.1~1V, 600ohm adjustable; Power in: 1V, 47Kohm,
Paging MIC IN: suitable M-E 01
Outputs Master Out: 600ohm, 1V, balanced (XLR), 1V unbalanced (Cinch);
Pre Out: 600ohm, 1V; Tape Out: 350 mV, 4,7Kohm
Colour housing Black
Material Metal
Dimensions Approx. 43 mm x 483 mm x 230 mm
Weight 3,2 kg
24. Door Control System and accessories 197
Technical data
Properties:
Current supply for the connected detectors and magnetic clamps
Alarm analysis and control
Integrated reset function
External load output for sirens and beacons
Up to 3 panels cascadable with control linkage
Status indication for alarm, fault and normal operation via LED
Connection of up to 10 detectors and 12 magnetic clamps
Suitable for applications in EX-zones
Operation voltage 230 V AC
Frequency 50 Hz ± 10 %
Output ext. Loads 800 mA
Potential free relay 1 Relay switch over 30 V/1 A for magnetic clamp
Ambient temperature 0°C to +40°C
Protection class IP 42
Colour housing RAL 9002 greywhite
Material ABS
Dimensions (H x W x D) 185 mm x 233 mm x 93 mm
Output voltage 24 V
Output current max. 800 mA
Weight 680 g
DIBT-Number Z-6.5-1646
24. Door Control System and accessories 198
Technical data
Properties:
Integrated professional smoke detection system with highest reliability for a secure
alarm verification with 16 fold measurement and intelligent logics
Intelligent analysis and disruption mode for the elimination of false alarms
Periodic sensor tests of the smoke chamber
Alarm output for the triggering of a LED indicators
Multicolour-LED for alarm- (red) and fault (yellow)
Integrated locking system for the protection against removal and tamper
Delivery including protective cover for installation phase
Operation voltage 9 to 33 V DC
Quiescent current 100 μA
Alarm current 20 mA
OC-outputs max. 50 mA for LED-indicator or piezo buzzer
Sensitivity < 0,15 dB / m
Ambient temperature -10°C to +60°C
Humidity Max. 93 % (+/-2%)
Air speed < 20 m/s
Protection class IP 40
Colour housing White (similar to RAL 9003)
Material ABS
Dimensions (H x Ø) 44 mm x 100 mm
VdS approval G203036
CPD- Number 0786-CPD-20042
DIBT-Number Z-6.5-1646
Standards DIN EN 54-7
24. Door Control System and accessories 199
Technical data
Properties:
Integrated professional smoke detection system with highest reliability for a secure
alarm verification with 16 fold measurement and intelligent logics
Intelligent analysis and disruption mode for the elimination of false alarms
Periodic sensor tests of the smoke chamber
Alarm output for the triggering of a LED indicators
Multicolour-LED for alarm- (red) and fault (yellow)
Integrated locking system for the protection against removal and tamper
Including white relays base with integrated relay board for the triggering of door controls
according to DIBT Z-6.5-1976 with 24 V via a potential free change-over contact
Operation voltage 9 to 33 V DC
Quiescent current 100 μA
Alarm current 20 mA
Outputs Relay 1 change-over contact 30 V / 1A in the base
Sensitivity < 0,15 dB / m
Ambient temperature -10°C to +60°C
Humidity Max. 93 % (+/-2%)
Air speed < 20 m/s
Protection class IP 40
Colour housing White (similar to RAL 9003)
Material ABS
Dimensions (H x Ø) 44 mm x 100 mm
VdS approval G203036
CPD- Number 0786-CPD-20042
DIBT-Number Z-6.5-1646
Standards DIN EN 54-7
24. Door Control System and accessories 200
Dimensions (H x W x D) 63 mm x 63 mm x 37 mm
Weight 76 g
Manual release switch uP for door controls
Art.-no. 30418 - Type HT uP
Description:
Manual release switch for the manual activation of door
controls in surface mounting design
Dimensions (H x W x D) 80 mm x 80 mm x 25 mm
Weight 93 g
Technical data for manual release
Properties:
Robust housing suitable for the surface mounting
Red rocker switch with inscription "Tür schließen"
Manual activation of the release switch gives way to a fire door
Ambient temperature -20°C to +60°C
Colour housing Red rocker, white corpus
Material ABS
General remarks Attention for mounting: Do not hide the manual switch by an open door.
24. Door Control System and accessories 202
Technical data
Properties:
Integrated release button for the manual interruption
Robust plastic housing with hidden cable entry for a protected connection
Integrated spark turn off diode for the protection in case of overvoltage
Integrated reverse voltage protection
Operation voltage 24 V DC ± 10 %
Alarm-/ operation current 67 mA (1,6 W)
Ambient temperature -20°C to +60°C
Protection class IP 40
Colour housing Black
Material Steel
Diameter 82 mm (magnet Ø 60 mm)
Height 70mm
Power-on time 100%
Holding force 700 N
Remanence 0N
Weight 100 g
DIBT-Number Z-6.5-1976
24. Door Control System and accessories 203
Technical data
Properties:
Rotary head for floor and ceiling mounting, with out change of the electrical connections
Length 175 mm, 90° pivoting, Length in pivoted status 137 mm
Robust plastic housing with hidden cable entry for a protected connection
Integrated release button for manual interruption
Integrated spark turn off diode for the protection in case of overvoltage
Integrated reverse voltage protection
Operation voltage 24 V DC ± 10 %
Alarm-/ operation current 67 mA (1,6 W)
Ambient temperature -20°C to +60°C
Protection class IP 40
Colour housing Light grey
Material Steel
Diameter 96 mm (magnet Ø 60 mm)
Dimensions (H x Ø) 107 mm x 96 mm
Power-on time 100%
Holding force 700 N
Remanence 0N
Weight 760 g
DIBT-Number Z-6.5-1976
General remarks A magnetic clamp, which keeps a fire door open, has to be activated
by a manual release switch, which is not hidden by an open door.
Installation of a manual release switch next to the door is necessary.
24. Door Control System and accessories 204
Technical data
Properties:
Rotary head for floor and ceiling mounting, with out change of the electrical connections
Length 325 mm, 90° pivoting, Lenght in pivoted status 287 mm
Robust plastic housing with hidden cable entry for a protected connection
Integrated release button for manual interruption
Integrated spark turn off diode for the protection in case of overvoltage
Integrated reverse voltage protection
Operation voltage 24 V DC ± 10 %
Alarm-/ operation current 67 mA (1,6 W)
Ambient temperature -20°C to +60°C
Protection class IP 40
Colour housing Light grey
Material Steel
Diameter 96 mm (magnet Ø 60 mm)
Dimensions (H x Ø) 257 mm x 96 mm
Power-on time 100%
Holding force 700 N
Remanence 0N
Weight 770 g
DIBT-Number Z-6.5-1976
General remarks A magnetic clamp, which keeps a fire door open, has to be activated
by a manual release switch, which is not hidden by an open door.
Installation of a manual release switch next to the door is necessary.
24. Door Control System and accessories 205
Technical data
Properties:
Rotary head for floor and ceiling mounting, with out change of the electrical connections
Length 475 mm, 90° pivoting, Length in pivoted status 437 mm
Robust plastic housing with hidden cable entry for a protected connection
Integrated release button for manual interruption
Integrated spark turn off diode for the protection in case of overvoltage
Integrated reverse voltage protection
Operation voltage 24 V DC ± 10 %
Alarm-/ operation current 67 mA (1,6 W)
Ambient temperature -20°C to +60°C
Protection class IP 40
Colour housing Light grey
Material Steel
Diameter 96 mm (magnet Ø 60 mm)
Dimensions (H x Ø) 407 mm x 96 mm
Power-on time 100%
Holding force 700 N
Remanence 0N
Weight 1.200 g
DIBT-Number Z-6.5-1976
General remarks A magnetic clamp, which keeps a fire door open, has to be activated
by a manual release switch, which is not hidden by an open door.
Installation of a manual release switch next to the door is necessary.
24. Door Control System and accessories 206
Technical data
Properties:
Integrated spark turn off diode for the protection in case of overvoltage
Reverse voltage protection
Robust housing with zinccoated surface
Operation voltage 24 V DC ± 15 %
Alarm-/ operation current 67 mA (1,6 W)
Ambient temperature -20°C to +60°C
Protection class IP 20
Colour housing Zinccoated
Material Steel
Diameter (Magnet Ø 60 mm)
Dimensions (H x Ø) 93 mm x 65 mm x 26 mm
Power-on time 100%
Holding force 700 N
Remanence 0N
Weight 1.200 g
DIBT-Number Z-6.5-1976
General remarks Cover available upon request
24. Door Control System and accessories 207
Technical data
Properties:
Integrated release button for a manual disruption
Robust plastic housing with hidden cable entry for a protected connection
Integrated spark turn off diode for the protection in case of overvoltage
Integrated reverse voltage protection
Operation voltage 24 V DC ± 10 %
Alarm-/ operation current 67 mA (1,6 W)
Ambient temperature -20°C to +60°C
Protection class IP 20
Colour housing White
Material Plastic
Diameter (Magnet Ø 60 mm)
Dimensions (H x Ø) 102 mm x 70 mm x 25 mm
Power-on time 100%
Holding force 700 N
Remanence 0N
Weight 500 g
DIBT-Number Z-6.5-1976
General remarks The terminal clamp is located on the base plate of the magnet
24. Door Control System and accessories 208
Technical data
Properties:
Design in solid aluminium cast housing and resistant against any
mechanical impact or foreign objects on the floor
Integrated spark turn off diode for the protection in case of overvoltage
Integrated reverse voltage protection
Operation voltage 24 V DC ± 10 %
Alarm-/ operation current 67 mA (1,6 W)
Ambient temperature -20°C to +60°C
Protection class IP 40
Colour housing Black
Material Aluminium
Diameter 3 x 9 mm (mounting holes for the floor mounting)
Dimensions (H x Ø) 100 mm x 165 mm x 107 mm
Power-on time 100%
Holding force 700 N
Remanence 0N
Weight 1.900 g
DIBT-Number Z-6.5-1976
24. Door Control System and accessories 209
Technical data
Properties:
Integrated spark turn off diode for the protection against overvoltage
Integrated reverse voltage protection
Robust housing with zinc coated surface
Operation voltage 24 V DC ± 10 %
Alarm-/ operation current 67 mA (1,6 W)
Ambient temperature -20°C to +60°C
Protection class IP 20
Colour housing Zinc
Material Steel
Diameter (Magnet Ø 50 mm)
Dimensions (H x Ø) 83 mm x 55 mm x 26 mm
Power-on time 100%
Holding force 600 N
Remanence 0N
Weight 402 g
DIBT-Number Z-6.5-1976
24. Door Control System and accessories 210
Technical data
Properties:
Integrated spark turn off diode for the protection in case of overvoltage
Reverse voltage protection
Robust housing with zinccoated surface
Operation voltage 24 V DC ±10 %
Alarm-/ operation current 71 mA
Ambient temperature -20°C to +60°C
Protection class IP 20
Colour housing Zinccoated
Material Steel
Diameter (Magnet Ø 70 mm)
Dimensions (H x Ø) 103 mm x 75 mm x 39 mm
Power-on time 100%
Holding force 1.450 N
Remanence 0N
Weight 1.074 g
DIBT-Number Z-6.5-1976
General remarks Cover available upon request
24. Door Control System and accessories 211
Technical data
Properties:
Including connection cable of 2m
Integrated spark turn off diode for the protection in case of overvoltage
Integrated reverse voltage protection
Operation voltage 24 V DC ±20 %
Alarm-/ operation current 70 mA (1,7 W)
Ambient temperature -20°C to +40°C
Protection class IP 66
Colour housing Zinc
Material Steel
Diameter (Magnet Ø 70 mm)
Dimensions (H x W x D) 110 mm x 75 mm x 43 mm
Power-on time 100%
Holding force 1.450 N
Remanence 0N
Weight 1.260 g
ATEX-Number ExII2GEExemIIT6
DIBT-Number Z-6.5-1976
General remarks Explosionproof magnetic clamps with connection cable are connected
to a junction box, which is provided by the customer and which is
installed outside of the explosive area or which is installed inside
the explosive area in explosionproof design.
Please consider the remarks for explosionproof components
24. Door Control System and accessories 212
Technical data
Properties:
Elastic connection piece for an adjustment of an angle up to 10 °
Zinc coated anchor plate
Colour housing Steel, Zinccoated
Material 64 mm (anchor plate)
Dimensions (H x W x D) 65 mm x 65 mm x 16 mm
Weight 280 g
General remarks The anchor plate requires at minimum the same diameter like the
pole face of the magnet to utilize its holding force.
Technical data
Properties:
Elastic connection piece for an adjustment of an angle up to 10 °
Zinc coated anchor plate
Colour housing Black
Material Steel
Diameter 64 mm (anchor plate)
Dimensions (H x W x D) 60 mm x 60 mm x 51 mm
Weight 230 g
General remarks The anchor plate requires at minimum the same diameter like the
pole face of the magnet to utilize its holding force.
24. Door Control System and accessories 213
Technical data
Properties:
Fibre-glass reinforced black robust plastic housing for heavy mechanical loads
Zinc coated anchor plate
Flexible support of the anchor plate for an adjustment of an angle up to 10°
Zinc coated anchor plate
Colour housing Black
Material Steel
Diameter 64 mm (anchor plate)
Dimensions (H x Ø) 82 mm x 80 mm
Holding force 100 N at 200 mm spring deflexion
Weight 350 g
General remarks The anchor plate requires at minimum the same diameter like the
pole face of the magnet to utilize its holding force.
Technical data
Properties:
Elastic connection piece for the adjustment of an angle up to 10 °
Zinc coated anchor plate
Material Steel, Zinccoated
Diameter 54 mm (anchor plate)
Dimensions (H x W x D) 55 mm x 55 mm x 16 mm
Weight 197g
General remarks The anchor plate requires at minimum the same diameter like the
pole face of the magnet to utilize its holding force.
24. Door Control System and accessories 214
Technical data
Properties:
Elastic connection piece for the adjustment of an angle up to 10 °
Zinc coated anchor plate
Material Steel, Zinccoated
Diameter 74 mm (anchor plate)
Dimensions (H x W x D) 75 mm x 75 mm x 20 mm
Weight 518 g
General remarks The anchor plate requires at minimum the same diameter like the
pole face of the magnet to utilize its holding force.
Technical data
Properties:
Angle joint with a slewing range of up to max. 60° in both directions
Zinc coated anchor plate
Colour housing Black
Material Steel
Diameter 74 mm (anchor plate)
Dimensions (H x W x D) 60 mm x 60 mm x 54 mm
Weight 395 g
General remarks The anchor plate requires at minimum the same diameter like the
pole face of the magnet to utilize its holding force.
24. Door Control System and accessories 215
Technical data
Properties:
Angle joint with a slewing range of up to max. 60° in both directions
Zinc coated anchor plate
Colour housing Black
Material Steel
Diameter 51 mm (anchor plate)
Dimensions (H x W x D) 60 mm x 60 mm x 51 mm
Weight 184 g
General remarks The anchor plate requires at minimum the same diameter like the
pole face of the magnet to utilize its holding force.
24. Door Control System and accessories 216
Technical data
Properties:
Rotary head, pivoting range up to 180°
Adjustable in height and length of up to 70 mm
Incl. 4 screws for the fixation of the magnetic clamps
Colour housing White (RAL 9010)
Material Sheet steel
Dimensions (Magnet Ø 60 mm)
Weight 612 g
Technical data
Properties:
Mounting angle with a lenght of minimum 500 mm
The distance from the ceiling to the top edge of the wall opening is more than 5 m
Wall mounted detectors are installed min. 3,5 m above the top edge
of the wall opening and at cantilever arm.
25. Testequipment for automatic detectors 218
Technical data
Properties:
Clear test cap for the visual control of the detector LED during smoke test
Spring loaded mechanism for effective, economic areosol release
Test cap sensitive to pressure - ideal for suspended / false ceilings
Telescope pole
Art.-no. 14006 - Type SOLO 100
Description:
4 section glass fibre telescope pole extandable to 4,5 m
Weight: 1,86 kg
Extension pole
Art.-no. 30193 - Type SOLO 101
Description:
Glass fibre extension pole; 1,13 m
max. 2 pieces per telescope pole
Bag
Art.-no. 14010 - Type SOLO 610
Description:
Carrying /Storage bag for test equipment
Integrated bag for telescope poles
Black synthetic material
With carrying strap
Dimensions (H x W x D): 460 mm x 45 mm x 180 mm
Weight: 3,44 kg
Testaerosol 250 ml
Art.-no. 31845 - Type TA 250
Testaerosol 35 ml
Art.-no. 32262 - Type TA 35
Description:
Non flammable testaerosol for ionisation and optical
smoke detectors
Art.-no.: 31845 250 ml bottle
Art.-no.: 32262: 35 ml bottle
Clean, non greasy, fast evaporating
Non flammable non self-sparking 250 ml bottle
Ambient temperature: 0°C up to +40°C
III. terms & conditions of sale detectomat GmbH 121
III. terms & conditions of sale detectomat GmbH 122
III. terms & conditions of sale detectomat GmbH 123