1

2
3
4
2

5
6
IS 1199 (Part 6) : 2018

All dimensions in millimetres.


FIG. 6 MEASUREMENT OF SEGREGATED P ORTION

28 TEST RESULT a) Identification of the test sample;


The segregated portion SR is calculated from the b) Location where the test was performed;
following equation and reported to the nearest c) Date and time of test;
1 percent. d) Ambient temperature;
e) Segregated portion SR, to the nearest
1 percent;
SR = f) Presence of bleed water, if any, after standing
for 15 min;
where g) Any deviation from the standard test method;
SR = segregated portion in percent; h) Declaration by the person technically
mps = mass of sieve receiver plus passed material, responsible for the test that it was carried out
in g; in accordance with this standard, except as
noted in (g).
mp = mass of the sieve receiver, in g; and
j) The report may include,
mc = initial mass of concrete placed onto the sieve,
in grams. 1) temperature of the concrete at the time
of test; and
29 TEST REPORT 2) time between completion of mixing and
The test report shall include the following: performance of the tests.