Waukesha gas engines Heat Rejection

HEAT REJECTION AND OPERATING DATA - MODEL L5794GSI


with emPact Emission Control System (Option Code 1005) & AFR2
130°F AUXILIARY WATER TEMP. – 180° JACKET WATER TEMP.
ENGINE SPEED — RPM
BMEP
(PSI) 900 1000 1100 1200
173 - 1264 1391 1517
158 1036 1151 1266 1381
POWER 140 921 1023 1125 1228
(BHP) 120 789 877 965 1052
100 658 731 804 877
80 526 585 643 702
173 - 7558 7642 7751
158 7538 7621 7705 7795
BRAKE SPECIFIC
140 7664 7743 7827 7914
FUEL CONS.
(BTU/BHP-HR) 120 7890 7966 8046 8134
100 8212 8292 8380 8473
80 8696 8782 8880 8987
173 - 9555 10628 11760
158 7809 8772 9756 10767
FUEL
140 7057 7922 8809 9717
CONSUMPTION
(BTU/HR x 1000) 120 6228 6986 7762 8560
100 5402 6060 6736 7430
80 4575 5134 5711 6305
173 - 2683 2963 3262
158 2249 2507 2766 3031
HEAT TO
140 2086 2322 2562 2805
JACKET WATER
(BTU/HR x 1000) 120 1897 2117 2342 2563
100 1698 1895 2097 2305
80 1493 1664 1843 2028
173 - 389 438 488
158 323 371 419 468
HEAT TO
140 309 354 400 447
LUBE OIL
(BTU/HR x 1000) 120 294 339 386 430
100 278 322 366 412
80 264 305 347 391
173 - 95 121 151
158 53 75 102 132
HEAT TO
140 32 49 71 98
INTERCOOLER
(BTU/HR x 1000) 120 12 23 37 58
100 -8 1 12 26
80 -30 -23 -14 -2
173 - 630 665 702
158 569 606 641 675
HEAT TO
140 543 578 613 645
RADIATION
(BTU/HR x 1000) 120 518 549 579 611
100 494 525 554 581
80 469 498 526 553
173 - 2541 2902 3296
TOTAL 158 1979 2284 2605 2946
ENERGY 140 1745 2014 2299 2597
IN EXHAUST 120 1498 1725 1962 2219
(BTU/HR x 1000) 100 1265 1458 1662 1873
80 1040 1202 1372 1550

Page 1 of 6

HEAT REJECTION AND OPERATING DATA


EN: 156988
Ref.
MODEL – L5794GSI WITH emPact EMISSION CONTROL SYSTEM S
(Option Code 1005), 54° C AUX. WATER TEMPERATURE DATE: 4/14
82° C JACKET WATER TEMPERATURE 6124-93
Waukesha gas engines Heat Rejection

ENGINE SPEED — RPM


BMEP
(PSI) 900 1000 1100 1200
EXHAUST 173 - 1102 1131 1161
TEMPERATURE 158 1044 1078 1109 1137
AFTER TURBINE 140 1016 1050 1082 1110
BEFORE 120 989 1020 1048 1077
CATALYST 100 961 993 1022 1047
(± 50° F)
80 930 962 991 1018
173 - 1779 1979 2189
158 1463 1639 1819 2005
INDUCTION AIR
140 1329 1489 1652 1818
FLOW
(SCFM) 120 1175 1316 1461 1608
100 1021 1144 1270 1399
80 867 971 1079 1189
173 - 7988 8885 9832
158 6571 7362 8167 9002
EXHAUST
140 5967 6684 7416 8163
GAS FLOW
(LBS/HR) 120 5276 5910 6559 7223
100 4586 5136 5702 6282
80 3895 4362 4844 5341
173 - 0.15 0.15 0.15
Catalyst out 158 0.15 0.15 0.15 0.15
NOx 140 0.15 0.15 0.15 0.15
EMISSION 120 0.15 0.15 0.15 0.15
(g/bhp-hr) 100 - - - -
80 - - - -
173 - 0.30 0.30 0.30
Catalyst out 158 0.30 0.30 0.30 0.30
CO 140 0.30 0.30 0.30 0.30
EMISSION 120 0.30 0.30 0.30 0.30
(g/bhp-hr) 100 - - - -
80 - - - -
173 - 0.14 0.14 0.14
Catalyst out 158 0.14 0.14 0.14 0.14
NMHC 140 0.14 0.14 0.14 0.14
EMISSION 120 0.14 0.14 0.14 0.14
(g/bhp-hr) 100 - - - -
80 - - - -
173 - 1.26 1.26 1.26
Catalyst out 158 1.26 1.26 1.26 1.26
THC 140 1.26 1.26 1.26 1.26
EMISSION 120 1.26 1.26 1.26 1.26
(g/bhp-hr) 100 - - - -
80 - - - -

Page 2 of 6

HEAT REJECTION AND OPERATING DATA


EN: 156988
Ref.
MODEL – L5794GSI WITH emPact EMISSION CONTROL SYSTEM S
(Option Code 1005), 54° C AUX. WATER TEMPERATURE DATE: 4/14
82° C JACKET WATER TEMPERATURE 6124-93
Waukesha gas engines Heat Rejection

HEAT REJECTION AND OPERATING DATA - MODEL L5794GSI


with emPact Emission Control System (Option Code 1005) & AFR2
130°F AUXILIARY WATER TEMP. – 180° JACKET WATER TEMP.
NOTES:
1 An adequate reserve should be used for cooling system or heat recovery calculations. See also Cooling System Guidelines, S-
6699-7, latest version.

2 ISO Standard (continuous) power ratings conform to ISO 3046/1, latest version, with a mechanical efficiency of 90%.
3 BSFC reported using LHV, refer to S-7884-7, latest version, for the full fuel specification.
4 Total Exhaust Energy includes both recoverable and non-recoverable heat. For a procedure to calculate recoverable heat refer to
S-8117-2, latest version.

5 Reference Engine Ratings and Fuel Consumption Curve Sheet C-278-13, latest version.
6 Exhaust flow at nominal 100kPa atmospheric pressure:

Flow (Exh. Flow, lb/hr) x (Exh. temp.


ACFM =
rate: °F+460°)
2250

Page 3 of 6

HEAT REJECTION AND OPERATING DATA


EN: 156988
Ref.
MODEL – L5794GSI WITH emPact EMISSION CONTROL SYSTEM S
(Option Code 1005), 54° C AUX. WATER TEMPERATURE DATE: 4/14
82° C JACKET WATER TEMPERATURE 6124-93
Waukesha gas engines Heat Rejection

— METRIC —
HEAT REJECTION AND OPERATING DATA - MODEL L5794GSI
with emPact Emission Control System (Option Code 1005) & AFR2
54°C AUX. WATER TEMPERATURE - 82°C JACKET WATER TEMPERATURE

BMEP ENGINE SPEED — RPM


(bar) 900 1000 1100 1200
11.94 - 943 1037 1131
10.87 772 858 944 1030
POWER 9.66 687 763 839 916
(kW) 8.28 589 654 719 785
6.90 490 545 599 654
5.52 392 436 480 523
11.94 - 10693 10812 10967
BRAKE 10.87 10665 10782 10902 11029
SPECIFIC 9.66 10842 10955 11074 11197
FUEL CONS. 8.28 11163 11270 11384 11508
(kJ/kWh) 6.90 11619 11732 11856 11987
5.52 12303 12425 12564 12715
11.94 - 2801 3115 3447
10.87 2289 2571 2860 3156
FUEL
9.66 2068 2322 2582 2848
CONSUMPTION
(kW) 8.28 1825 ` 2275 2509
6.90 1583 1776 1974 2178
5.52 1341 1505 1674 1848
11.94 - 786 868 956
10.87 659 735 811 888
HEAT TO
9.66 611 681 751 822
JACKET WATER
(kW) 8.28 556 621 687 751
6.90 498 555 614 676
5.52 438 488 540 594
11.94 - 114 128 143
10.87 95 109 123 137
HEAT TO
9.66 90 104 117 131
LUBE OIL
(kW) 8.28 86 99 113 126
6.90 82 94 107 121
5.52 77 89 102 115
11.94 - 28 36 44
10.87 15 22 30 39
HEAT TO
9.66 9 14 21 29
INTERCOOLER
(kW) 8.28 4 7 11 17
6.90 -2 0 4 8
5.52 -9 -7 -4 -1
11.94 - 185 195 206
10.87 167 178 188 198
HEAT TO
9.66 159 169 180 189
RADIATION
(kW) 8.28 152 161 170 179
6.90 145 154 162 170
5.52 137 146 154 162

Page 4 of 6

– Metric –
HEAT REJECTION AND OPERATING DATA EN: 156988
Ref.
MODEL – L5794GSI WITH emPact EMISSION CONTROL SYSTEM S
DATE: 4/14
(Option Code 1005), 54° C AUX. WATER TEMPERATURE
82° C JACKET WATER TEMPERATURE
6124-93
Waukesha gas engines Heat Rejection

BMEP ENGINE SPEED — RPM


(bar) 900 1000 1100 1200
11.94 - 745 850 966
TOTAL 10.87 580 669 763 863
ENERGY 9.66 511 590 674 761
IN EXHAUST 8.28 439 506 575 651
(kW) 6.90 371 427 487 549
5.52 305 352 402 454
11.94 - 594 611 627
EXHAUST
TEMPERATURE 10.87 562 581 598 614
AFTER TURBINE 9.66 547 566 583 599
BEFORE 8.28 532 549 565 581
CATALYST 6.90 516 534 550 564
(± 30° C)
5.52 499 517 533 548
11.94 - 2734 3041 3365
10.87 2249 2520 2795 3081
INDUCTION AIR
9.66 2042 2288 2538 2794
FLOW
(nm3/hr) 8.28 1806 2023 2245 2472
6.90 1570 1758 1952 2150
5.52 1333 1493 1658 1828
11.94 - 3623 4030 4460
10.87 2981 3339 3704 4083
EXHAUST
9.66 2707 3032 3364 3703
GAS FLOW
(kg/hr) 8.28 2393 2681 2975 3276
6.90 2080 2330 2586 2849
5.52 1767 1979 2197 2423
11.94 - 0.06 0.06 0.06
Catalyst out 10.87 0.06 0.06 0.06 0.06
NOx 9.66 0.06 0.06 0.06 0.06
EMISSION 8.28 0.06 0.06 0.06 0.06
(g/nm3 at 5% O2) 6.90 - - - -
5.52 - - - -
11.94 - 0.11 0.11 0.11
Catalyst out 10.87 0.11 0.11 0.11 0.11
CO 9.66 0.11 0.11 0.11 0.11
EMISSION 8.28 0.11 0.11 0.11 0.11
(g/nm3 at 5% O2) 6.90 - - - -
5.52 - - - -
11.94 - 0.05 0.05 0.05
Catalyst out 10.87 0.05 0.05 0.05 0.05
NMHC 9.66 0.05 0.05 0.05 0.05
EMISSION 8.28 0.05 0.05 0.05 0.05
(g/nm3 at 5% O2) 6.90 - - - -
5.52 - - - -
11.94 - 0.47 0.47 0.47
Catalyst out 10.87 0.47 0.47 0.47 0.47
THC 9.66 0.47 0.47 0.47 0.47
EMISSION 8.28 0.47 0.47 0.47 0.47
(g/nm3 at 5% O2) 6.90 - - - -
5.52 - - - -

Page 5 of 6

– Metric –
HEAT REJECTION AND OPERATING DATA EN: 156988
Ref.
MODEL – L5794GSI WITH emPact EMISSION CONTROL SYSTEM S
DATE: 4/14
(Option Code 1005), 54° C AUX. WATER TEMPERATURE
82° C JACKET WATER TEMPERATURE
6124-93
Waukesha gas engines Heat Rejection

— METRIC —
HEAT REJECTION AND OPERATING DATA - MODEL L5794GSI
with emPact Emission Control System (Option Code 1005) & AFR2
54°C AUX. WATER TEMPERATURE - 82°C JACKET WATER TEMPERATURE
NOTES:
1 An adequate reserve should be used for cooling system or heat recovery calculations. See also Cooling System Guidelines, S-
6699-7, latest version.

2 ISO Standard (continuous) power ratings conform to ISO 3046/1, latest version, with a mechanical efficiency of 90%.
3 BSFC reported using LHV, refer to S-7884-7, latest version, for the full fuel specification.
4 Total Exhaust Energy includes both recoverable and non-recoverable heat. For a procedure to calculate recoverable heat refer to
S-8117-2, latest version.

5 Reference Engine Ratings and Fuel Consumption Curve Sheet C-278-13, latest version.
6 Exhaust flow at nominal 100kPa atmospheric pressure:

Flow (Exh. Flow, kg/h) x (Exh. temp.


m3/hr =
rate: °C+273°)
332.96
*Trademark of INNIO. All other trademarks are the property of their respective owners.

Page 6 of 6

– Metric –
HEAT REJECTION AND OPERATING DATA EN: 156988
Ref.
MODEL – L5794GSI WITH emPact EMISSION CONTROL SYSTEM S
DATE: 4/14
(Option Code 1005), 54° C AUX. WATER TEMPERATURE
82° C JACKET WATER TEMPERATURE
6124-93