RAC RP Hs lS
Lessee maRea
S)
Control Cable with PVC Insulation and Sheath
AP HiT REE ASOTSOVR TIS, UIE
RRR RTA.
—. PRATER —GB/TS30-2008
{RARE
1, AONE Ob HMA CIELAB 70°C.
2. RMB RIF O'C, HHO HH Ae
FMERVBIE, MAF MINEMNELE.
AURA RRS. MIF MIME 12
ARMRRNNKEM, AR FamEMots.
SAUER RACH
It is used for supervising and controlling return circuit
and protective circuit of A.C rated voltage of 450/750V or
lower.
Executive standard: G8/T9330-2008
Working Condition
41: Long term working temperature of conductor
allowed by cable is 70°C.
2: Environment temperature for installation is no less
than orc
Min, bending radius of cable is no less than 6 times
that of cable OD for cable without armoring, 12 times for
‘cable with armoring or metalic tape shielding and 6 times
{for soft cable with shielding structure.
‘Type, Description and Application Occasion
SORAC MERA CHE TA OR SEA. EY THES
kw | Control cable with Cu core, PVC insulation and| To be fixedly laid indoor, in cable furow, pipe
sheath
SUNGCRERRACEPERTRTAOR |RUEEA tS TASER
kyvp | Control cable with Cu care, PVC insulation and| To be fixedly laid indoor, in cable furrow, pipe with demand on
sheath, braided shielding shielding
WORACERGRA LET ER ENRON (MULE OS ToS
kvve2 | Control cable with Cu core, PVC insulation and| To be fixedly laid indoor, in cable furrow, pipe with demand on)
sheath, copper tape shielding ehielsing
SSRAZTERERAHPSESURTHER [META ks. RFRA REA
Kvv22 | Control cable with Cu core, PVC insulation and| To be fixedly aid indoor, in cable furrow. pipe, underground with
sheath, steel lape armoring demand on enduring strong mechanical forco
SORGCMRRACNPERHATROM OS | MOTTA Wy, SOE SERETAMM DSTA
Kvv32_| Control cable with Cu core, PVC insulation and| To be fixed lad indoor, in cable farm, pipe, shaft with demand on.
sheath, steel wire armoring enduring stiong mechanical force
AER RCGES 2PM SREEABOSR RES
KWVR_ [Control soft cable with Cu core, PVC insulation | To be laid indoor with demand on mobilty and softness
‘and sheath
ANS 7RERUSZTRPERAMRLUATE | RBC RAEORREM RETA
kuvrP [Control soft cable with Cu core, PVG insulation | To be laid indoor with demand cn shielding and softness.
‘and sheath, braiding shielding
2 ORARERME RA, KENETE RA, eR eER TE pTIN ZR
ZR ewes
QRRRP RE. SMM MERRIER. fo. KUve2-22. KURO
5.
Note: 1: We also produce flame retardant cable according tothe
requirements of customer Prefix “ZR” shouldbe added Ep ZR-KW
type
We leo produce cable whieh dose not belong to standars type
according te the requirement of customer 9 KVVP2 22, KVVP32
#48159918701H Various Specification Range
Kw
nin ~ 2-61 14
KvvP2 = aot aia
Kw22 | as0rre0| 78 6 ania
Kwvse = 1s-64 Tost ata
KWR 461 =
KWRP +51 i ae = =
2) RMEEMATD. 2.9.4, 5.7.0, 10,12,
5iaaas, e201,
14.10.19, 26, 27,30,
Note: Cores recommenced: 2.34 57.81012,1416,19 24,2730.37.4.48,
SoretADEA RIERA Typical Cable Structure and External
Dimension
KVVERERATREE REESE
KVV type control cable with Cu corLessee maRea
0x6 i 20 0.0070 TOKE i 2s ‘30070
“0x6 2 235 0.0065 12K6. 2 240) 9.0065
10x10. 2 28.0 0.0065 i 1 i 1
14x0.75 4 129 0.012 TKO 1 735 D072
14x0.75 2 131 oot 186X075 2 145 ore
14x10 4 137 ‘ont 18X10 4 14a 011
14x10 2 147 0.013 16X10 2 160 0.013
1aKi5 1 154 ‘oon 36x15 1 163 ‘oon
14x15 2 170 0.010 16x15 2 178 ‘0.010
14x 4 180 0.010 16x2. 4 19. 0.010
14x25 2 200 0.009 16X25 2 23 (0.009
aXe 4 204 0.0085 L i i 1
axe 2 a 0.0077 L Z 0 z
4x6 41 26 0.0970 L rl n Z
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
fi
2ex075
26x075
24x10
27x10
2ax1 5
24x15
24x25
0x0 75
'30x0.75
‘30x10
30x10
30x15
30x25
30x25
“46x0.75
46x0.75
‘4aX10
aaxt 0
aaxi5
4axi 5
4x2.
48X25
52X075
52X075
‘52X10
52X10
a
52x15
52x25
52X25
eix15
B1x1 5
81x25
61x25®
KVP RSL tetOss Psa ARIE OE
KVP type control cable with Cu core, PVC insulation and sheath, braided shielding
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
‘STXOTE
‘ax
exis
‘Sx25
eX075
“8x10
aex1 5
48x25
BiX075
Bix
eixts
aixasLessee maRea
KVVP2RSE ERT HR RP RAD IONS
KVVP2 type control cable with Cu core, PVC insulation and shoath,copper tape shieldingKVV220 ERAT EMR PROM
KVV22 type control cable with Cu core, PVC insulation and sheath, steel tape armoring