You are on page 1of 4

measuring

Flowmeters and Switches for •

very Low Flows monitoring



KDF for liquids · KDG for gases analysing

KDF/ KDG

OO Flow rates:
water 0.25 - 2.5 … 16 -160 l/h
air 0,5 - 5 … 500 - 5000 Nl/h
OO Accuracy: ±2.5 % qG = 50 %
OO pmax: PN 16; tmax: 100 °C

S1
OO Connection: ¼" NPT female or
G ¼ female, hose nozzle 8 mm
OO Material: stainless steel

KOBOLD companies worldwide: KOBOLD Messring GmbH


Nordring 22-24
AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHINA, CZECHIA, EGYPT, FRANCE, D-65719 Hofheim/Ts.
GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, Head Office:
NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SPAIN, SWITZERLAND, +49(0)6192 299-0
+49(0)6192 23398
THAILAND, TUNISIA, turkey, USA, VIETNAM info.de@kobold.com
1/10 - 2018

www.kobold.com

1
Flowmeters and Switches for very Low Flows Model KDF/KDG

Method of Operation Limit switches (Option)


The flowmeters and switches for very low flows model KDF The flowmeters can be fitted with limit switches as an option.
and KDG for liquids and air operate on the suspended float These limit switches are ring-type proximity switches. The
principle: that is, the installation position is vertical and the electrical connection is via a 2 m cable or junction box.
direction of flow is from bottom to top. The electrical characteristic values for all types are according
The instruments have been designed as simple and thus to DIN 19234 (NAMUR).
economical measuring systems. The float is a ball, whereby Isolation switching amplifiers are necessary to operate these
the indication point is the upper edge of the ball. A needle ring-type proximity switches (see Accessories brochure).
valve is fitted as standard.
The following types are available:
Areas of Application Monostable
KDF- and KDG-versions Are used preferably as Min. or Max. contact.
KDF-... for liquids Bistable
KDG-... for gases As limit contact used at any position of the measuring tube.
Technical Details Important! The contact cannot be switched at the relative
upper range value from product size KDF-2239 and
Installation position: vertical, flow from bottom
KDG-2257 upward.
Accuracy: •±  2.5% qG 50 acc. VDE/VDI 3513
page 2 Differential pressure controllers (Option)
• ±3% of full scale Differential pressure controllers are suitable for maintaining a
(upstream pressure controller) constant flow rate of liquid and gaseous products in pipelines.
±5% of full scale (downstream The differential pressure controller consists of stainless steel
pressure controller) with an integrated membrane made of FPM or PTFE and a
(within 10-100% of measuring counterbalance valve of stainless steel.
range) The membrane of the controller is in balanced condition
Max. pressure: PN16 when the pressure conditions on both sides are equal. The
Process temperature: -20 °C ... +100 °C pressure on the incoming side is determined by the medium
-20 °C ... +70 °C with contact pressure. The pressure on the output side is determined by
the pressure loss of the adjustment valve at the flowmeter.
Ambient temperature: -20 °C ... +100 °C
-20 °C ... +70 °C with contact During a one-sided pressure change on the incoming or
output side, a pressure compensation takes place across
Protection type: IP 65 (EN60529)
the integrated diaphragm valve which holds the set flow rate
Repeatability: ±1,0 % FS
constant.
(Differential pressure
The version to use for gases for constant upstream pressure
regulator): ±1,5 % / 2,5 % FS
Connection: ¼" NPT; G ¼ (female backward) is “valve up” and for constant downstream pressure “valve
down”.
Option: hose nozzle for 8 mm hose
For liquids the valve position is without effect on the function
Weight: approx. 0.45 kg
of measuring device.
approx. 0.8 kg with controller
Important! The controller can only regulate the pressure
Materials (in contact with the media)
fluctuations of inlet or outlet.
Fitting: stainless steel 1.4401
The pressure condition of the other side has to be stable.
Measuring tube: borosilicate glass
Min.- pressure difference between inlet and outlet side:
Float stop: PTFE 350 mbar.
Float: stainless steel 1.4404 Max.- load of membrane at one-side load: 7 bar
Gasket: FPM, option FFKM
Two types are available:
Valve stem: stainless steel 1.4404
Upstream pressure controller (KDF-/KDG- ...E, F)
Valve seat: PTFE 25% C (carbon fibre)
Upstream pressure controllers hold the flow for gases and
Hose nozzle: polyamide
liquids constant with variable upstream pressure and
ATEX approval constant downstream pressure.
(on request from our sister company Heinrichs, Model: K12) Downstream pressure controller (KDF-/KDG-...A, B)
Explosion protection:  II 2GD IIC TX (for mech. Downstream pressure controllers hold the flow of gaseous
instrument) media and liquids constant with variable downstream
Contacts ignition pressure and constant upstream pressure. Preferably, these
category: PTB 00 ATEX 2128 X should be used for liquids.
II 2G Ex ia IIC T6-T4
(c/w limit switches)
 1/10 - 2018

2 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.
Flowmeters and Switches for very Low Flows Model KDF/KDG

Standard with needle valve Panel mount with differential pressure controller

Liquids Order Details (Example: KDF-2217 N V 0 M1 0)


Measuring Valve seat Pressure Order no. Connection Gasket Panel Contact option Miscellaneous
range water [mm] Drop stainless option installation options
[l/h] [mbar] steel kit
00 = without contact
0.25 - 2.5 1.2 10 KDF-2217...
upto model KDF-2220 0 = without
with 2 m cable E = differential pres.
0.5 - 5 1.2 20 KDF-2220... M1 = 1 monostable contact
contr. with
M2 = 2 monostab. contacts
constant outlet
N1 = 1 bistable contact pressure, valve
1.2 - 12 2.8 10 KDF-2225... N2 = 2 bistable contacts at input ¼" NPT,
N = ¼" NPT
with junction box3) FPM
KDF-2228... R = G ¼
4)
2.5 - 25 2.8 20 A1 = 1 monostable contact A = differential pres.
W = hose A2 = 2 monostab. contacts contr. with
connector B1 = 1 bistable contact constant inlet
4 - 40 2.8 30 KDF-2230... angular, 90°, pressure, valve
V = FPM 0 = without B2 = 2 bistable contacts
for 8 mm hose at output ¼" NPT,
T = FFKM S4)5) = with FPM
6 - 60 2.8 80 KDF-2235... S = hose from model KDF-2225
connector mit 2 m Kabel F = as 'E' however
straight, for M3 = 1 monostable contact with FFKM
10 - 100 2.8 125 KDF-2239...1) 8 mm hose M4 = 2 monostab. contacts instead of FPM
N3 = 1 bistable contact B = as 'A' however
Y = special
N4 = 2 bistable contacts with FFKM
12 - 120 3.4 200 KDF-2240...1)
instead of FPM
with junction box3) Y = e. g. without
A3 = 1 monostable contact valve. Please
16 - 160 3.4 200 KDF-2241...1)
A4 = 2 monostab. contacts specify in
B3 = 1 bistable contact writing
other B4 = 2 bistable contacts
on request on request KDF-22YY...
liquids

Gases Order Details (Example: KDG-2207 N V 0 M1 0)


Measuring Valve seat Pressure Order no. Connection Gasket Panel Contact option Miscellaneous
range air2) [mm] Drop stainless option installation options
[Nl/h] [mbar] steel kit
0.5 - 5 1,2 15 KDG-2207... 00 = without contact
0.8 - 8 1,2 15 KDG-2209... upto model KDG-2224 0 = without
1.6 - 16 1,2 15 KDG-2213... with 2 m cable E = differential pres.
M1 = 1 monostable contact
contr. with
4 - 40 1,2 20 KDG-2221... M2 = 2 monostab. contacts
constant outlet
6 - 60 1,2 25 KDG-2224... N1 = 1 bistable contact
pressure, valve
10 - 100 2,8 15 KDG-2229... N2 = 2 bistable contacts
at input ¼" NPT,
N = ¼ NPT
25 - 250 2,8 15 KDG-2232... with junction box 3) FPM
R =G¼
4)

50 - 500 2,8 15 KDG-2237... A1 = 1 monostable contact A = differential pres.


W = hose A2 = 2 monostab. contacts contr. with
80 - 800 2,8 20 KDG-2242... connector B1 = 1 bistable contact constant inlet
100 - 1000 2,8 25 KDG-2246... angular, 90°, V = FPM 0 = without B2 = 2 bistable contacts pressure, valve
for 8 mm hose at output ¼" NPT,
180 - 1800 2,8 80 KDG-2251... T = FFKM S4)5) = with FPM
S = hose from model KDG-2229
240 - 2400 2,8 125 KDG-2257...1) connector F = as 'E' however
with 2 m cable
300 - 3000 2,8 150 KDG-2261...1) straight, for with FFKM
M3 = 1 monostable contact
8 mm hose instead of FPM
400 - 4000 3,4 200 KDG-2264...1) M4 = 2 monostab. contacts
B = as 'A' however
Y = special N3 = 1 bistable contact
500 - 5000 3,4 200 KDG-2268...1) with FFKM
N4 = 2 bistable contacts
other gase on request on request KDG-22YY... instead of FPM
mit with junction box3) Y = e. g. without
1)
The limit switch is only available as a min. contact. A3 = 1 monostable contact valve. Please
2)
At 1.2 bar absolute and 20 °C A4 = 2 monostab. contacts specify in
3)
Not with panel installation kit B3 = 1 bistable contact writing
4)
Not with differential pressure controller B4 = 2 bistable contacts
5)
Not with junction box
 1/10 - 2018

No responsibility taken for errors; www.kobold.com 3


subject to change without prior notice.
Flowmeters and Switches for very Low Flows Model KDF/KDG

Dimensions [mm]

Standard with needle valve with panel installation kit

40 45 32
NPT ¼" / G ¼"

180

125

163
125

145
80
4,2

22,5

2,5

~32-42

with contacts and junction box with differential pressure controller with constant outlet
pressure
56,5
42 56,5
Gewindeanschluss
NPT ¼" / G ¼"
Thread connection
1/4" NPT
Gewindeanschluss
36 1/4" NPT
¼" NPT
10,5

60
Ø4,2

60
180
180

1,5
7
7
125
80

83
197

83
22,5

Gewindeanschluss
Ø105 Thread connection
1/4" NPT
Gewindeanschluss
Ø105 1/4" NPT
¼" NPT
~ 220 - 230
~ 220 - 230
61,5


51


with differential pressure controller with constant inlet
23,5

pressure
~ 75-85 32

Ø 105 Thread connection


Gewindeanschluss
¼" NPT
1/4" NPT
83

7
180

60

Thread connection
56,5
¼" NPT
Gewindeanschluss
1/4" NPT

~ 220 - 230
 1/10 - 2018

4 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.

You might also like