Automatic control systems enable us to operate our processes in a safe and profitable manner.

Consider, as on this site, processes with streams comprised of gases, liquids, powders, slurries and
melts. Control systems achieve this “safe and profitable” objective by continually measuring process
variables such as temperature, pressure, level, flow and concentration – and taking actions such as
opening valves, slowing down pumps and turning up heaters – all so that the measured process
variables are maintained at operator specified set point values.

Safety First

The overriding motivation for automatic control is safety, which encompasses the safety of people, the
environment and equipment.

The safety of plant personnel and people in the community are the highest priority in any plant
operation. The design of a process and associated control system must always make human safety the
primary objective.

The tradeoff between safety of the environment and safety of equipment is considered on a case by
case basis. At the extremes, the control system of a multi-billion dollar nuclear power facility will permit
the entire plant to become ruined rather than allow significant radiation to be leaked to the
environment.

On the other hand, the control system of a coal-fired power plant may permit a large cloud of smoke to
be released to the environment rather than allowing damage to occur to, say, a single pump or
compressor worth a few thousand dollars.

The Profit Motive

When people, the environment and plant equipment are properly protected, our control objectives can
focus on the profit motive. Automatic control systems offer strong benefits in this regard.

Plant-level control objectives motivated by profit include:

▪ meeting final product specifications


▪ minimizing waste production

▪ minimizing environmental impact

▪ minimizing energy use

▪ maximizing overall production rate

It can be most profitable to operate as close as possible to these minimum or maximum objectives. For
example, our customers often set our product specifications, and it is essential that we meet them if
failing to do so means losing a sale.

Suppose we are making a film or sheet product. It takes more raw material to make a product thicker
than the minimum our customers will accept on delivery. Consequently, the closer we can operate to
the minimum permitted thickness constraint without going under, the less material we use and the
greater our profit.

Or perhaps we sell a product that tends to be contaminated with an impurity and our customers have
set a maximum acceptable value for this contaminant. It takes more processing effort (more money) to
remove impurities, so the closer we can operate to the maximum permitted impurity constraint without
going over, the greater the profit.

Whether it is a product specification, energy usage, production rate, or other objective, approaching
these targets ultimately translates into operating the individual process units within the plant as close as
possible to predetermined set point values for temperature, pressure, level, flow, concentration and the
other measured process variables.

Controllers Reduce Variability

As shown in the plot below, a poorly controlled process can exhibit large variability in a measured
process variable (e.g., temperature, pressure, level, flow, concentration) over time.

Suppose, as in this example, the measured process variable (PV) must not exceed a maximum value. And
as is often the case, the closer we can run to this operating constraint, the greater our profit (note the
vertical axis label on the plot).
To ensure our operating constraint limit is not exceeded, the operator-specified set point (SP), that is,
the point where we want the control system to maintain our PV, must be set far from the constraint to
ensure it is never violated. Note in the plot that SP is set at 50% when our PV is poorly controlled.

Below we see the same process with improved control. There is significantly less variability in the
measured PV, and as a result, the SP can be moved closer to the operating constraint.

With the SP in the plot below moved to 55%, the average PV is maintained closer to the specification
limit while still remaining below the maximum allowed value. The result is increased profitability of our
operation.

Terminology of Control

We establish the jargon for this site by discussing a home heating control system as illustrated below.
This is a simplistic example because a home furnace is either on or off. Most control challenges have a
final control element (FCE), such as a valve, pump or compressor, that can receive and respond to a
complete range of controller output (CO) signals between full on and full off. This would include, for
example, a valve that can be open 37% or a pump that can be running at 73%.

For our home heating process, the control objective is to keep the measured process variable (PV) at the
set point value (SP) in spite of unmeasured disturbances (D).

To achieve this control objective, the measured process variable is compared to the thermostat set
point. The difference between the two is the controller error, which is used in a control algorithm such
as a PID (proportional-integral-derivative) controller to compute a CO signal to the final control element
(FCE).

The change in the controller output (CO) signal causes a response in the final control element (fuel flow
valve), which subsequently causes a change in the manipulated process variable (flow of fuel to the
furnace). If the manipulated process variable is moved in the right direction and by the right amount,
the measured process variable will be maintained at set point, thus satisfying the control objective.

This example, like all in process control, involves a measurement, computation and action:

▪ is the measured temp colder than set point (SP – PV > 0)? Then open the valve.

▪ is the measured temp hotter than set point (SP – PV < 0)? Then close the valve.

Note that computing the necessary controller action is based on controller error, or the difference
between the set point and the measured process variable, i.e.

e(t) = SP – PV (error = set point – measured process variable)

In a home heating process, control is an on/off or open/close decision. And as outlined above, it is a
straightforward decision to make. The price of such simplicity, however, is that the capability to tightly
regulate our measured PV is rather limited.

One situation not addressed above is the action to take when PV = SP (i.e., e(t) = 0). And in industrial
practice, we are concerned with variable position final control elements, so the challenge elevates to
computing:

▪ the direction to move the valve, pump, compressor, heating element…

▪ how far to move it at this moment

▪ how long to wait before moving it again

▪ whether there should be a delay between measurement and action