Thanks for choosing the Advanced & Safe control system: i-con for escalator & moving walks.
This manual generally introduces i-con control system in VVVF control.
This document is of commercial confidential. Please keep it safe.
All specifications and information are subject to change without further notice.
Page 1 of 21
JSA07898E-AA i-con(2.0)Control System instruction
Catalog
1. General instruction ................................................................................................................................. 4
1.1. Standard Features ...................................................................................................................... 4
1.2. Optional Features ....................................................................................................................... 6
2. Instructions of function and principle ................................................................................................... 8
2.1. System framework ...................................................................................................................... 8
2.2. Safety device ............................................................................................................................... 9
2.3. Diagrammatic sketch of control box ....................................................................................... 10
3. Installation and adjustment.................................................................................................................. 10
3.1. Check Wire Before Power Supply .......................................................................................... 10
3.2. Instructions of errors and their reset ...................................................................................... 11
3.3. Brake switch inspection ........................................................................................................... 11
3.3.1 Errors from SPC ....................................................................................................................... 11
3.3.2 Errors from PLC ....................................................................................................................... 12
3.3.3 Errors from A5 .......................................................................................................................... 13
3.3.4 Errors from A7 .......................................................................................................................... 13
3.4. Maintenance inching operation ............................................................................................... 14
3.5. Inspection running .................................................................................................................... 14
3.6. Normal running .......................................................................................................................... 14
4. Instructions of operate function .......................................................................................................... 15
4.1. Soft stop ..................................................................................................................................... 15
4.2. Automatic lubrication ................................................................................................................ 15
4.3. Service brake power ................................................................................................................. 16
4.4. Traffic light indicator.................................................................................................................. 16
5. Energy saving function......................................................................................................................... 16
5.1. Continuous running .................................................................................................................. 16
5.2. Normal energy saving running with inverter ......................................................................... 16
5.3. Auto-start running with inverter ............................................................................................... 17
6. Drawing sym instruction....................................................................................................................... 18
All rights reserved under International Copyright Conventions. No part of the contents of this
manual may be copied, reproduced or transmitted in any form or by any means or translated into
another language or format, in whole or in part, without the written consent.
Page 2 of 21
JSA07898E-AA i-con(2.0)Control System instruction
After opening the landing plate, the landing plate detection switch will be actived
and then break the safety circuit. The buzzer could be bypassed by opening the
inspection socked.
Don’t bypass the landing plate detection switch to avoid the failure of safety
function.
Landing plate switch, sag switch, handrail speed sensor and step missing sensor
will be bypassed automatically in inspection mode.
A part of special errors are keeped after power off. They could be reseted by
pressing down the reset button for twice in 3 seconds. Output port SO1 and SO2 of
SPC will be actived if the reset is successful.
Page 3 of 21
JSA07898E-AA i-con(2.0)Control System instruction
1. General instruction
The control system includes 3 parts, top machine room, bottom machine room and main body.
Please refer to electrical circuit diagram and cable layout.
Page 4 of 21
JSA07898E-AA i-con(2.0)Control System instruction
Page 5 of 21
JSA07898E-AA i-con(2.0)Control System instruction
Page 6 of 21
JSA07898E-AA i-con(2.0)Control System instruction
E-brake [YB3]
One emergency brake is installed on the drive shaft. It always opens after power on. And in
following case, E-brake will stop the escalator.
Over speed (over 120% of rated)
Drive chain broken
Unintentional reversal of the travel direction
Power supply interrupted, E-brake will activate with 3~5 seconds time delay to avoid its
damage
Note: according to standard, E-brake must be equipped for the escalator rise over 6m.
Page 7 of 21
JSA07898E-AA i-con(2.0)Control System instruction
Remote monitoring-Communication(RMS)
By Modbus-RTU communication, realize monitoring escalator status in local monitor room.
The communication able to monitor room provided by consumer.The optional function for
consumer are monitor software and softdog etc.
Page 11 of 21
JSA07898E-AA i-con(2.0)Control System instruction
Errors of SPC
Error code Name Error code Name
E100 Reserved E136 Reserved
E101 Overspeed 1.2 Times E138 Drive Chain 1 Switch
E102 Overspeed 1.4 Times E139 Drive Chain 2 Switch
E103 Unintended Reverse E140 Unintended Reverse (DN)
E104 Brake Distance Over Limit E141 T Step Missing Sensor Error
E105 L Handrail Under Speed E142 B Step Missing Sensor Error
E106 R Handrail Under Speed E143 T Passenger Stop
E107 T Step/Pallet Missing E144 B Passenger Stop
E108 B Step/Pallet Missing E145 Reserved
E109 Brake Open Failed E146 Speed Sensor Error
E110 Brake Close Failed E147 Pulse AB Reversed (DN)
E111 Reserved E148 Direction Sign Error (Shorted)
E112 Start Status without AB Pulse E149 Brake 1 Open Failed R
E113 Reserved E150 Brake 1 Open Failed L
E125 Auxiliary Brake Feedback Error E151 Brake 2 Open Failed R
E126 Underspeed E152 Brake 2 Open Failed L
E127 L Handrail Sensor Broken E153 Brake 1 Close Failed R
E128 R Handrail Sensor Broken E154 Brake 1 Close Failed L
E129 Reserved E155 Brake 2 Close Failed R
E132 Reset Button Stuck E156 Brake 2 Close Failed L
E133 Direction Signal Error (Lost) E157~199 Reserved
E134 Auxiliary Brake Control Failed
E135 EDM
Page 12 of 21
JSA07898E-AA i-con(2.0)Control System instruction
Page 13 of 21
JSA07898E-AA i-con(2.0)Control System instruction
continuously running .Escalator will start acceleration till full speed. Main motor (MT) for the
Star-triangular connection.
Page 15 of 21
JSA07898E-AA i-con(2.0)Control System instruction
Page 16 of 21
JSA07898E-AA i-con(2.0)Control System instruction
escalator will work in creeping speed by the inverter’s characteristic. As soon as the
passenger entry is detected, the escalator will smoothly accelerate to normal speed. Turn on
the energy saving switch, it will be into the continuous mode.
5.3.2. Photo-electric sensors for passenger detection [B31], [B32], [B41], [B42]
At the function of Normal energy saving running with inverter or beam-type self-starting, you
can choose Through-beam photo-electric sensors installed on the upper and lower.
Passenger can be detected by these sensors at the entrance and export to achieve energy
saving running. 2 couples of sensors are installed on each fore skirting or upright post
according to function and type of escalator.
Photo-electric sensors of self-starting function escalator can not be installed on
skirting in order to avoid dangerous by passages.
Page 17 of 21
JSA07898E-AA i-con(2.0)Control System instruction
Page 19 of 21
JSA07898E-AA i-con(2.0)Control System instruction
Page 20 of 21
JSA07898E-AA i-con(2.0)Control System instruction
Page 21 of 21