You are on page 1of 13

Specifications for E2 Digital Color Doppler Ultrasound System

SonoScape Medical Corp


 Pediatric
1. General Specification  Cephalic
 Fetal
The system adopts the advanced ultrasonic
 Trans-rectal
Doppler technologies, including the Full  Trans-vaginal
Digital Super-wide Band Beam Former,
Digital Dynamic Focusing, Variable Aperture
2.2 Standard Features
and Dynamic Tracing, Wide Band Dynamic
Range, and Multi-Beam Parallel Processing, 2.2.1 Imaging Modes
etc. Users can perform the system with the
 B-Mode (B)
minimum requirement of training or
 Tissue Harmonic Imaging (THI)
guidance. This system has been designed
 Pure Inversion Harmonic Imaging (PIH)
to comply with applicable international  Color Flow Mapping (CFM)
standards and regulations, ensuring the  Power Doppler Imaging (PDI)

safety and availability of this product.  Directional Power Doppler Imaging (DPDI)
 Pulsed Wave Doppler (PW)
This system is based on the computer
 M-Mode (M)
technology and Linux operation system,
which make the system more flexible and 2.2.2 Functions

stable. System maintenance and function


 2D Speckle Reduction & Edge Enhanced (2D
update can be completed by software μ-scan)
updating, through which would promote  Spatial Compound Imaging (SCI)

product value and keep the technological  PW auto trace


 Trapezoid imaging
advancement.
 Real-time 2DPanoramic Imaging
 Dual Live
 Auto (One button optimization for 2D/M/CW/ PW)
2. System Overview  Image Rotation Function
 Auto IMT measurement
2.1 Applications  TEI index
 Standby mode
 Abdominal  Biopsy guide
 Vascular  Full screen zoom
 Cardiac  Show gallery
 GYN/OB  DICOM 3.0
 Urology  Triplex
 Musculo-skeletal
 Small organ

901-03134-A01
E2 Technical Specifications

2.3 Optional Features  Anti-flickering

3.3 Probe Sockets and Holders


 VIS-Needle (Needle Visualization Enhancement )
 Panoramic Imaging (Real-time 2D)  Probe Sockets:3 probe sockets (Only 2 active for

 Tissue Doppler Imaging (TDI) standard) and 3 holders

 SR Flow Imaging
 Color M mode (CFM+M)
3.4 Operation Environment
 Anatomic M-Mode (AMM, Steer M)
 Lateral Gain Compensating (LGC)
 Temperature: +10°C-+40°C
 Continuous Wave Doppler (CW)
 Relative Humidity: 30% -85% (no condensation)
 Wi-Fi (DICOM)
 Atmospheric Pressure: 700-1060hPa
 B/I Box Extender with ECG
 B Mode Prospective Saving
3.5 Transportation and Storage
Environment
2.4 Language Support

 Temperature: -20°C - +55°C


 Software:
 Relative Humidity: 20%-90% (no condensation)
English, Simple Chinese, Spanish, Russian,
 Atmospheric pressure: 700-1060hPa
French, German, Portuguese, Italian, Norwegian
 Keyboard Input:
3.6 Power Supply
Danish, Swedish, Finnish, Portuguese, German,
Spanish, French, Portuguese, Turkish.
 AC/DC Adaptor:
Additional Requirement: Russia.
 Input: 100-240Va.c., 1.5-0.75A, 50-60Hz;
 Output: 19Vd.c., 4.74A
3. Physical Specification
 Main unit: 19Vd.c., 4.74A
3.1 Dimensions and Weight

 Height: 352mm
4. Imaging Parameters
 Width: 378mm
 Depth: 114mm
4.1 B-Mode
 Weight: approx. 6.1kg (without battery)
approx. 6.5kg (with battery)  Display Format: B, Dual (B+B), Quad (4B)
 Gain: 1-255 adjustable
3.2 Monitor
 Frame Rate: up to 80 fps (Probe dependent)
 Gray Shades: 256
 15.6-inch widescreen and high resolution color
 Scan Depth: 40.0 cm (Probe dependent)
LCD monitor
 Image Zoom (Ratio: 0.8-10 times)
 Resolution: 1920*1080

901-03134-A01
E2 Technical Specifications

 TGC: 8-level slides, adjustable Optimization)


 LGC Left & LGC Right: adjustable
 Image Flip: Left/ Right, Up/Down 4.2 Color/PDI
 Panoramic: available
 Gain: 0-255
 Compound Imaging: Off, 1, 2, 3,4 (Probe
 Frame Rate: up to 209 fps (Probe dependent)
dependent)
 Size and Position of Color ROI: adjustable
 PHI/THI: On/Off
 Image Flip: Up/Down, Left/Right
 Frequency: 5 bands, adjustable
 Frequency: 3 levels, adjustable
 Chroma: 12 types, selectable
 Wall Filter: 5 levels, Min, Low, Med, High, Max
 μ-Scan: Off,1,2,3,4,5 adjustable
adjustable (Probe dependent)
 Line Density: 3 levels, adjustable
 PRF: 0.5-10kHz (Probe dependent)
(High/Medium/Low)
 Line Density: 4 levels (Min/Low/ Med/ High)
 Persist: Off, Low, Med, High, Max 4 levels ,
 Color Map: 1-5 levels for CFM mode
adjustable
 Persist: 4 levels, Off/Low/Med/High/Max
 Biopsy Guide: Off/On (preset adjustable)
adjustable (Probe dependent)
 Dot Size: Min, Med, Max, 3 levels adjustable
 B Reject: 0-255 adjustable
 Biopsy Calibration
 Steer: 0°, ±8, ± 12°, ± 16°adjustable
 Angle adjustable
 PDI: On/Off
 Offset adjustable
 Color Map (PDI)/DPDI: 7 types selectable, former
 Save
 for PDI, latter for DPDI (Probe dependent)
 Load Default
 Dual Live: On/Off
 Dynamic Range (DYN): 20-200 (Probe
 Invert: On/Off
dependent)
 Gray Map: 16 levels, selectable (Probe
dependent) 4.3 M-Mode
 Sector Width: adjustable
 Focus Position: adjustable  AMM: On/Off, 3 sample lines
 Focus area 1 -21  Frequency: 5 levels, adjustable
 Power%: 1-100 adjustable, 5 step each  Gray Map: 16 types, selectable
 Tissue Specific Imaging (TSI): Adipose, Muscle,  Chroma: 12 types, selectable
Fluid, Normal tissue  Display Format: V2/1, V1/1, V1/2, H1/1, Full
 Widescan: Off/On  Sweep Speed: 5 levels adjustable for M mode
 Steer: 0, ±2°, ± 4°, ±6°degrees, adjustable (Min/ Slow/ Med/ Fast/ Max), and 5 levels
 Rotation: Off/ 90°/ 180°/ 270° adjustable for AMM (Min/ Slow/ Med/ Fast/ Max)
 Vis-Needle AMM Power%: 1-100, adjustable
 On/Off  Focus area:1-21 levels, adjustable
 Steer Angle  Persist: Low, Med, High, Max 4 levels, adjustable
 Dual Live: On/Off  Power:1-100%, selectable
 Auto (One-button B-mode Parameter

901-03134-A01
E2 Technical Specifications

4.4 PW/CW Mode  Auto focus


 Inversion: On/Off
 Doppler Methods
 Power: 1% - 100%
 PW Doppler
 Frequency range: 3 steps, adjustable
 CW Doppler
 PRF: 0.5 - 10KHz (probe dependent)
 Simult: On/Off
 Line density: Low, Med, High adjustable
 Sample Volume (PW): 0.5-24.0 mm, adjustable
 Color Map: 10 levels
 Position: adjustable
 Dual Live: On/Off
 Invert: On/Off
 Flow Reject: 1 - 255
 Quick Angle: 0°, 60°, -60°, adjustable
 θ Correction: θ angle correction: -88°to 88°, 2°
steps each 5. System Setting
 (Real-time) Auto Trace: On/Off
 Baseline: 9 levels, adjustable 5.1 General
 Frequency: 3 levels, adjustable
 Wall Filter: 5 levels, Min, Low, Med, High, Max, 5.1.1 General Settings
adjustable
 Hospital Name
 PRF: 1-16 kHz (PW) (Probe dependent)
 Freeze Response: Cine, Annot, Body
 PRF: 1-50KHz (CW) (Probe dependent)
mark, Arrow
 Max Velocity Range
 Trackball Sensitivity: 1, 2, 3, 4, 5
 ±0.0576 - ±6.14m/s (PW) (probe
 Language: English, Simplified Chinese,
dependent, sampling angle range: ±60°)
Spanish, Russian, French, Italian,
 ±0.0761 - ±10.35m/s (CW) (probe
Germany, Norwegian,Portuguese
dependent, sampling angle: 0)
 Time Zone
 Sweep Speed: 5 levels, adjustable (Min/ Slow/
 Date/Time Setting
Med/ Fast/ Max)
 Date Format: MM/DD/YYYY,
 Chroma: 12 types, selectable
YYYY/MM/DD, DD/MM/YYYY, selectable
 Display Format: V2/1, V1/1, V1/2, H1/1, Full,
 Time Format: 12 Hour, 24 Hour, selectable
 Steer: 4 levels: 0°, ± 8°,± 12°, ± 16°, adjustable
 Volume: 0-100, 5 each step, adjustable
5.1.2 Display
 Power:1-100%
 Auto (One-button Parameter Optimization)  Screen Saver: On/ Off
 Baseline  Screen Saver wait (min): 5-60 minutes
 PRF  Auto standby wait (min): 20-90 minutes
 Key Volume: On/Off
 Keyboard & Monitor Brightness
4.5 Tissue Doppler Mode (TDI)  Monitor Colors: Warm/Cool
 Gain: 0 - 255  Width Ruler: On/Off
 Frame rate: 121 fps (probe dependent)  Trackball Light Color: 6 types
 Size and position of color ROI: adjustable  Show Gallery
901-03134-A01
E2 Technical Specifications

 Config.: Top, up, down, bottom


 Play Interval:1-5 seconds, selectable
 Import 5.3 Comment
 Delete
 Load Default  5.3.1 Tools
 Exit  Annotation

 Select annotation Language


5.1.3 Save
 Font size

 Retrospective store  Clear annotation while unfreezing

 Prospective store image

 Freeze Store  Arrow

 Save Format/Area  Arrow size: Large/Medium/Small

Cine Format: AVI, WMV  Clear arrow while unfreezing image: On/Off

 Image Format: BMP, JPG, TIF


 Area: Full Screen, Image Area, Image  5.3.2 List
area+InfoBar
 Classified by specific exams: Abdomen,
 Save Operation
Obstetrics, Gynecology, Vascular, Breast,
Send image to DICOM storage
Cardiology, Urology, Small parts, Musculoskeletal
Send cine to DICOM storage
 Edit comment item
 Key Function
 Add to Library
 P1,P2,F3,F4, Cine
 Delete
 Selected (Comment List):
5.1.4 Biopsy
 To first

 Biopsy Guide Line  Previous

 Bracket  Next

 Guide line type: Line, Range  To Last

 Guide line display: On/Off


5.4 Bodymark
 DICOM Print
 Biopsy Grid
 Classified by specific exams: Abdomen,
 Biopsy Grid Display Style: +/.
Obstetrics, Gynecology, Vascular, Breast,
 Biopsy Grid Display Color:
Cardiology, Urology, Small Parts, Musculoskeletal
Green/Yellow

5.2 Exam Preset

 Probe Selection
Available Items
Selected Items

901-03134-A01
E2 Technical Specifications

5.5 Measure  CUA


 Equation (SMP)
5.5.1 General  Thyroid (Volume) Calculation Coefficient: 0.52
(US). 0.479 (EURO), selectable
 BSA (Body Surface Area): Eastern, Western  Load default
 Cross Cursor Size: Small, Medium, Large,
selectable 5.5.3 List
 Measure Line Size: Small, Medium, Large
 Distance Dash Line Display: On/ Off For editing measure lists classified into different

 Velocity Cross Line Display: On/ Off applications, categories and modes.

 Ellipse Cross Line Display: On/ Off


 Volume Flow Method: TAmean/TAmax  Application: Abdomen, Urology, Small parts,

 Volume Flow compensation with TAmax: 0.5 – Gynecology, Obstetrics, Vascular, Cardiology,
Pediatrics, selectable
1.0
 Measurement Categories: Caliper, Calculation,
 Keep Result Window : On/ Off
selectable
 Result Font Color: White/Yellow
 Mode: B, Color, M, Doppler, selectable
 Result Position:
 List (items): Category, Collection, Measurement
 2D: Right Top, Right Bottom, Left Top, Left
 Measurement (Adjust Position): Add, Delete,
Bottom, selectable
Reorder
 M+D: Right Top, Right Bottom, Left Top,
 Load default
Left Bottom, selectable

5.5.2 Application 5.6 Report

 Auto/ Manual Trace: Abdomen, Urology, Small  Logo

Parts, Gynecology, Obstetrics, Vascular, Cardiac,  Operation LOGO: Upload logo

selectable  Left/Right: Choose logo

 Num 0-9: Editable shortcut keys of measurement  Title/Font/Color:

(OB/GYN//Cardiac)  Title 1/ Title 2/ Title 3

 Measurement Setting (OB)  Title 1/ Title 2/ Title 3/ Title/

 CUA/AUA SubTitle/Content

 Add 1 week to EDD (Yes/ No) Font Size: 14-26, adjustable, 2 each

 Show EDD on screen (Yes/ No) step

 Growth Deviation Display: No, %, SD,  Content Font Size: 12-16,adjustable, 1

selectable each step

 Equation (OB)  Background Color: Basic Colors (48 types),

 GA & Growth (New Table): New GA Table, Screen Color

New Growth Table  Text Color: Basic Colors (48 types), Screen

 Fetal Weight: Estimation, Age by EFW, Color

EFW GP/SD, Unit  Display Items for Report:

901-03134-A01
E2 Technical Specifications

 Patient Information  Advance (Advanced Setting)


 Exam Information  Network Name
 Measurements (selectable)  Signal Level
 Image (selectable): 1*1, 2*2, 3*3,  Encryption
selectable  DHCP/Static IP (IP Address, Netmask,
 Graphs (selectable) Default Gateway)
 Comment (selectable)
 Preview

5.8 DICOM
5.7 Peripheral

5.8.1 Local Setting


5.7.1 Basics

 Local Device
 Video output
 Station Name
 Area: Picture
 AE Title
area/FullScreen/Info+PictureArea
 Port Number
 CVBS/S-VIDEO: NTSC/PAL/Close
 Timeout(sec)
 HDMI: Close/1920*1080  Storage Setting:
 Printer  2D Compression:None/RLE/JPEG
 Default Printer: USB Printer/Windows  2D JPEG Quality
Printer  Cine Compression:None/RLE/JPEG

 Printer IP Address  Cine JPEG Quality


 Send at end of exam: On/Off
 Printer Port Number

 Foot Switch 5.8.2 DICOM Service


 Left/Right Key
 Service List:
5.7.2 Network  Service Type
 Service Name
 Local Network  AE Title
 DHCP/Static IP  IP Address
 DHCP: MAC Address  Port
 Static IP: IP Address, Netmask, Default
Gateway, Mac Address 5.9 Help
 Ping IP Address
 Wireless Network (Enable/Disable):  User manual
 List (Name, State, Level)
 Connect
 Disconnect
 Refresh

901-03134-A01
E2 Technical Specifications

 B+CFM+M

5.10 Load Default  Anatomical M mode

5.10.1 Load 7. Connections

5.10.2 New: 7.1 Ethernet Network

 StoreName
7.2 USB
 Replace
 New  USB 2.0: 3 ports

5.10.3 Export/Import:
7.3 Wireless Network

 USB Drive
7.4 DICOM 3.0
 Copy user setting to USB
 Copy user preset to USB
 Storage: directly transmits images with patient
 Load USB user setting to system
information to a DICOM file server
 Load USB user preset to system
 Medical digital images and communication
 Export Log
DICOM 3.0 interface

5.11 About
8. Optional Transducers
 General: System information
8.1 Phased Array Probe
6. Display Formats
 3P-A
 B+B Frequency: 1.0 - 6.0MHz
 4B  7P-B
 B + CFM
Frequency: 2.0 - 9.0MHz
 B + PDI
 B+DPDI
 B+TDI
8.2 Linear probes
 B+M
 B+PW  L741
 B+CFM+PW
Frequency: 4.0 - 16.0MHz
 B+PDI+PW
 10I2
 B+DPDI+PW
 B+TDI+PW Frequency: 4.0 - 16.0MHz

 B+CW  L746
 B+CFM+CW Frequency: 4.0 - 12.0MHz
 B+PDI+CW
901-03134-A01
E2 Technical Specifications

9. Safety and Conformance


8.3 Convex probes
9.1 Quality Standard
 3C-A

Frequency: 1.0 - 7.0MHz  ISO 9001


 6V1  ISO 13485

Frequency: 3.0 - 15.0MHz


9.2 Safety Standard
 C361

Frequency: 2.0 - 6.0MHz Comply with IEC 60601-1, Class I BF,


 C613 Comply with IEC 60601-1-2, Group 1, Class B

Frequency: 4.0 - 13.0MHz Comply with IEC 60601-2-37

 EC9-5
9.3 Certification
Frequency: 3.0 - 15.0MHz
FDA & CE: E2 Digital Color Doppler Ultrasound
System is conferred the FDA certification by the
Food and Drug Administration.

10. Image/ Patient Data


Management

 Static and Dynamic image storage


 Support review of past exam by clipboard
 Patient Registration: Name, ID, Gender, Date of
Birth, Height, Weight, LMP, EDD and GA.
 Patient data and reports are archived by patient
exams
 Reports and images can be previewed
 Preview size can be set to 1*1, 2*2,
 File can be previewed, deleted, used for DICOM
Send and DICOM Print or exported
 Files can be exported to the USB drive or DVD.
BMP, JPG, TIF, AVI, WMV, PDF, TXT are
selectable for export format

901-03134-A01
E2 Technical Specification V1.0

11. Preset Function


 Users can customize the presets based on
different probe and diagnostic part to optimize
imaging parameters
 Users can arrange the presets
Users can import or export presets (not
including default preset)

Page 12 of 13
S50 Technical Specifications

NOTE:
 Sonoscape reserves the rights to change the specifications without prior
notification.
 Some products or features may not be available in some countries.
 For more information, please contact your local SonoScape sales representative.

Contact US:
Address: 4/F, 5/F, 8/F, 9/F & 10/F, Yizhe Building, Yuquan Road, Nanshan,
Shenzhen, 518051, Guangdong, China
Tel: +86-755-26722890
Fax: +86-755-26722850
Email: Service@sonoscape.net
Website: http://www.sonoscape.com

Page 13 of 13

You might also like