You are on page 1of 2
a | UNITED RUBBER INDUSTRIES (1) PVT. LTD QAy0R/5 Rev:01 CERTIFICATE OF CONFORMANCE ‘Dt: 01.08.2006 Control & Switchgear Company Ltd BDK / C-656-1/603 Dated : 21.06.2008 1841 Dated. 12.07.2008 RUBBER BELLOW 670x250 As per drawing 2Nos. Sr. Parameter UOM | Specification | Test findings Conctasion 1. | Hardness Shore A 6347 68 ‘Complies 2. | Tensile strength Bar 70210 fa ‘Complies 3. | Elongation at break % 650450 625 ‘Complies 4. | AFTER AGEING @ 105°C FOR 7 DAYS ASTM-D 573-4 a. | Change in hardness: _ 43 to +7 +4 ‘Complies b. | Change in tensile % +15 78 ‘Complies cc. | Change in elongation % -10 to -35 “18.6 ‘Complies 5. | Polymer identification - EPDM EPDM Complies . = ‘BOmega ohms " 6. | Insulation Resistance value [with 500v} Passed Complies PREPARED BY: Priyanka T. ib {QA-Officer) QA)” (a) UNITED RUBBER INDUSTRIES (1) PVT. LTD onomio PREDISPATCH INSPECTION REPORT ‘Des 01.08.2006 Control & Switchgear Company Ltd BDK/C-656-1/603 Dated : 21.06.2008 194 Dated. 12.07.2008 RUBBER BELLOW 670x250 2Nos. URI/CSGL /398 dtd.12.07-2008 pa pe |e oo = eae Visual | OK | OK ‘Complies 2 | inner dia 70 Measuring tape | 662 664 Complies 3. | Height 250 Scale 252 250 Complies 4. | Thickness 10 T Vernier RA 93 ‘Complies 5. No. of holes. 16 Visual 16 16 ‘Complies 6. | Hole dia “4 Vernier 140 13.56 Complies Pz [p> 730 | Measuringtape | 730 730 Complies 8. Dimension 30 ‘Vernier 321 WA Complies - Dimension 2 ‘Vernier 20.6 203 ‘Complies PREPARED BY: BY: (QA-Officer) ‘ay