Professional Documents
Culture Documents
Inverter
NVF2 Inverter
1. General
NVF2 series inverter is a high-performance open-loop vector
inverter of self-developed. It features high starting torque
(0.5Hz, 1.5 times rated torque), high overload capacity,
convenient operation and forward and reverse PID control.
This series consists of three types: mini-inverter, universal
(overloading) and fan pump (light load), features good load
adaptability, stable and reliable operation and automatic energy-
saving operation. The products are widely used in electric drive
and automation control fields, such as paper making, textile,
water supply, municipal administration, food, cement, printing
and dyeing and plastic machinery.
01 > >>
Inverter & Soft-Starter
Inverter
2. Features
PLC
MODBUS
> >> 02
Inverter & Soft-Starter
Inverter
3. Multiple features of software
Ensure the output voltage stability during operation of the Automatic operation with maximum efficiency
inverter Depending on the load and speed, test the load current and
When the grid voltage fluctuates, the output voltage of the provide the most efficient voltage to the motor to achieve the
inverter will not vary with fluctuations of grid voltage. most energy-efficient operation.
Protect the machinery to ensure reliable operation of mechanical Reduce mechanical wear
equipment When little water is used at night, the inverter output frequency
Facilitate protection of machinery because the torque generated is lower than the frequency of sleep, the inverter enters the sleep
by the motor can be controlled within the set value. mode.
Improve the reliability of continuous operation Enhance the low frequency output torque under V/F control
Even if the inverter detects failure, it will automatically reset after mode
the self-diagnosis, and restart without interrupting the motor For manual /automatic torque boost setting under V / F mode,
operation. Automatic reset for 3 times. which can effectively increase low torque of inverter.
03 > >>
Inverter & Soft-Starter
Inverter
4. Technical data
> >> 04
Inverter & Soft-Starter
Inverter
4.2 NVF2 standard technology features
Programmable Digital Input: Mini: 5-circuit; Universal, fan and pump type: 6-circuit
Programmable Analog Input: AI1: (0 ~ 10) V input; AI2: (0 ~ 10) V or (0/4 ~ 20) mA; AI1 + AI2
Peripheral
Open collector output: 1 output
interface
Relay output: Mini: 1 output; Universal, fan pump: 2-circuit outputs
Analog output: 2-circuit outputs, respectively, optional (0 ~ 10) V or (0/4 ~ 20) mA (Mini type 1-circuit)
Torque boost: Automatic torque boost; manual torque boost of 0.1% -30.0%
Energy consumption braking: internal or external braking unit, an external braking resistor
DC braking: start, stop, respectively, optional, operating frequency (0 ~ 10) Hz, braking current (0 to 150)%,
operating time (0.0 ~ 50.0) s
Jog Control: Jog Frequency range: (0 ~ 400) Hz, jog acceleration and deceleration time (0.1 ~ 3600.0) s
Ope rat ion
fun ction Multi-speed operation: multi-speed run through the built-in simple PLC or control multi-function terminals
cha rac teristics Automatic voltage regulation (AVR): When the grid voltage changes, AVR can automatically maintain constant output voltage
Automatic current limiting: Automatically limit the current during running to prevent fault trip frequently due to over-current
Built-in PID controller: can easily form into closed loop control system
Custom JOG function keys: JOG keys can be set to jog running or switch between forward and reverse operation
Protection: Provides up to 20 kinds of fault protection features: over-current, overvoltage, under-voltage,
over-temperature, phase-lack, overload, PID disconnection and other protection features.
Technical Starting torque: Vector control without PG: 0.5Hz/150% (rated torque)
characteristics Speed ratio: vector control without PG: 1:100; V / F control: 1:50
Speed control accuracy: (vector control without PG): ± 0.5% maximum speed
Carrier frequency: (1 ~ 15) kHz
Temperature: Operating ambient temperature between -10 ℃ ~ 40 ℃, when exceeding 40 ℃, derate by 1% per increase of 1℃
Humidity: relative humidity of the air in the operating environment ≤ 95%, non-condensing
Operating Altitude: below 1000m,when altitude is over 1000m, derate by 10% per increase of 1000m
environment
Shock and vibration: Do not install in a place susceptible to frequent shock
Electromagnetic radiation: Install at place away from sources of electromagnetic radiation
Air pollution: Do not install at place of air pollution, such as dust, corrosive gases and other similar environment
05 > >>
Inverter & Soft-Starter
Inverter
5. Wiring diagram
Circuit
breaker Contacto r + B
B
-
R U
Power S V
Input M
T W
Motor Grounding
Inverter grounding Main circuit terminals
COM
COM
> >> 06
Inverter & Soft-Starter
Inverter
5.1.2 Standard wiring diagram for universal type, fan and pump type
External braking
DC reacto r resistor
Circuit
Contacto r
breaker +2
+1 B
B
-
R
R U U
Power S
S V V
Input T
T W
W
M
Motor Grounding
Inverter grounding Main circuit terminals
X6
COM
COM
protocol COM
07 > >>
Inverter & Soft-Starter
Inverter
5.2 Terminals annotation
5.2.1 Main circuit terminals annotation
25
73.5(W1)
63
15.6
93
JOG - +
SHIFT
<
PRG SET
<
RUN STOP
> >> 08
Inverter & Soft-Starter
Inverter
H1
H
W1 4Xd D1
W D
NVF2-11/TS4 ~ 220/PS4
H1
H
D1
W1 4Xd
W D
NVF2-220/TS4 ~ 315/PS4
W D W1 W1
H1
H
D1
09 > >>
Inverter & Soft-Starter
Inverter
6.2 Product mounting dimensions
NVF2-22/TS4(30/PS4)
300 596 345 210 568 210 8 27
NVF2-30/TS4(37/PS4)
NVF2-37/TS4(45/PS4)
NVF2-45/TS4(55/PS4) 355 691 395 280 664 220 8 45
NVF2-55/TS4(75/PS4)
NVF2-75/TS4(90/PS4)
380 750 410 300 716 190 9 60
NVF2-90/TS4(110/PS4)
NVF2-110/TS4(132/PS4)
485 920 445 400 880 230 12 115
NVF2-132/TS4(160/PS4)
NVF2-160/TS4(185/PS4)
NVF2-185/TS4(200/PS4) 590 1080 475 450 1040 233 12 160
NVF2-200/TS4(220/PS4)
NVF2-220/TS4(245/PS4)
NVF2-245/TS4(280/PS4) 710 1010 385 250 968 410 13 165
NVF2-280/TS4(315/PS4)
1. Improve or suppress the distortion rate of grid voltage and current waveforms due to the pulse
DC reactor current discharged by filter capacitor;
2. Reduce the harmonic content and improve the quality of power supply from grid.
1. Control the boost of bus voltage pump, forming certain protective effect to the inverter;
Brake unit
2. When frequent braking is required, the braking capability of the inverter can be improved.
Can consume the mechanical energy from motor braking in the form of heat through braking resistor,
Braking resistor
and shorten the deceleration time of inverter drive system.
When the operation panel of inverter needs to be installed on the door panel of control cabinet,
Keyboard tray
or requires operation cabinet for remote control, keyboard tray is required for installation.
Display extension cable Use as extension cable when using remote control or outside pulling of the operation panel.
> >> 10
Inverter & Soft-Starter
Inverter
Optional accessories form
Configuration
Configuration
Brake unit
Rated Rated Rated
configuration Inductance Inductance (mH)
Power Current Current Configuration Current
(10% braking Resi st an ce (mH) (mH) Inductance
NVF2-□/□□□ un it( Ω) (W) (A) (A) (A)
rate)
External optional
15/PS4,15/TS4 40 1560 34 0.397 35 0.25 — —
18.5/PS4,18.5/TS4 32 4800 38 0.352 40 0.2 — —
22/PS4,22/TS4 27.2 4800 50 0.26 50 0.18 70 0.9
30/PS4,30/TS4 Built-in 20 6000 60 0.24 63 0.09 80 0.86
Built-in
37/PS4,37/TS4 braking unit 7000 75 0.235 80 0.08 100 0.7
16 optional
optional
45/PS4,45/TS4 13.6 9600 91 0.17 100 0.06 (including 120 0.58
(including
55/PS4,55/TS4 10 12000 112 0.16 125 0.04 110/PS4 146 0.47
110/PS4
models)
75/PS4,75/TS4 models) 6.8 12000 150 0.12 160 0.035 160 0.36
90/PS4,90/TS4 6.8 12000 200 0.0705 200 0.023 180 0.33
110/PS4,110/TS4 6 20000 224 0.0692 224 0.016 250 0.24
132/PS4,132/TS4 6 25000 280 0.0503 280 0.016 Standard 280 0.24
built-in
160/PS4,160/TS4 2.5 50000 315 0.0447 315 0.013 340 0.16
185/PS4,185/TS4 External 400 0.0352 400 0.011 460 0.09
200/PS4,200/TS4 brake unit 400 0.0352 400 0.011 460 0.09
220/PS4,220/TS4 optional 450 0.0313 560 0.009 500 0.82
Standard
245/PS4,245/TS4 560 0.0251 600 0.008 600 0.072
external
280/PS4,280/TS4 560 0.0251 600 0.008 600 0.072
315/PS4 640 0.0224 690 0.006 700 0.068
Corresponding
physical drawing
of each accessory
showing
showing
Physical drawings extension
box pallets
showing extension cable
cable and showing
box pallets
Note: If the inverter panel needs to be externally pulled for operation control, the user needs to specify when ordering,
and indicate the length of the extension cord displayed.
11 > >>
Inverter & Soft-Starter
Inverter
8. Ordering information
8.1 Type designation
NVF2-□/□ □ □
Inverter
Company code
When ordering, please select the desired models and specifications in accordance with the instructions on models and
meaning,:
For example:
Single phase 220V series: NVF2-0.75/TD2
Three-phase 380V universal: NVF2-45/TS4
Three-phase 380V fan & pump: NVF2-55/PS4
8.2 Guide for Model Selection
8.2.1 In order to ensure reliable operation of the inverter, the inverter power must be greater than or equal motor power.
8.2.2 The universal inverter is mainly used for load other than fans and pumps, such as: rolling mill, mixer, ball mill,
centrifuges and other heavy loads.
8.2.3 The fan & pump inverter is mainly used for light load e.g. fan and pump.
> >> 12