Inverter & Soft-Starter

Inverter
NVF2 Inverter
1. General
NVF2 series inverter is a high-performance open-loop vector
inverter of self-developed. It features high starting torque
(0.5Hz, 1.5 times rated torque), high overload capacity,
convenient operation and forward and reverse PID control.
This series consists of three types: mini-inverter, universal
(overloading) and fan pump (light load), features good load
adaptability, stable and reliable operation and automatic energy-
saving operation. The products are widely used in electric drive
and automation control fields, such as paper making, textile,
water supply, municipal administration, food, cement, printing
and dyeing and plastic machinery.

Products applicable equipment

Fan Pump Air Conveyor Food Packaging


conditioner machinery machinery

01 > >>
Inverter & Soft-Starter
Inverter
2. Features

PLC

MODBUS

2.1 Excellent motor drive control performance


● High starting torque: 0.5Hz 150% of rated motor torque;
● Superior energy savings, the lighter the load on the motor, the lower the efficiency; through energy-saving control, improve the
running efficiency of the motor, regardless of the load changes, the motor is always running at high efficiency state;
● Accurate motor parameters self-learning function: accurate comprehensive and static motor parameters self-learning, convenient
commissioning, easy operation, which can improve the control precision and the response speed;
● Speed tracking:when to restart the motor after instantaneous power cut and restoration ,it can quickly determine the turn direction
and speed of motor, and continuing to run smoothly;
● Built-in DC reactor (110kW or more), effectively suppress higher harmonics.
● Unique dead zone compensation technique can improve the output torque;
● Wide carrier frequency, (1 ~ 15) kHz, which can effectively reduce the running noise of motor;
● Super overload - 150% of rated current sustained for 1min, and under heavy load situation, not susceptible to frequent tripping due to
overload to ensure the continued stability of the device;
● Real-time load monitoring - Real-time monitoring of bus voltage and motor current to ensure smooth start and stop, and fast-track.

2.2 High reliability design


● Wide input voltage range of design: Input voltage range up to ± 15%;
● Automatic Voltage Regulator (AVR) and automatic current limiting function, the system runs more stable;
● Perfect protection and fault diagnosis system, to provide security for the device, Reliable protection.

2.3 Rich application functionality


● RS-485 communication interface, and standard MODBUS communication protocol, enabling external PLC equipment to make
network automation and control;
● Pendulum frequency functions, applicable for the textile industry;
● Built-in intelligent PID control and sleep function, achieving energy efficient;
● Simple PLC control: Simple PLC function enables the inverter to run at variable speed according to a certain law operation; it not only
can define all multi-stage frequency of one cycle in the function code, it also can define multi-stage frequency time,direction and cycles
in the function code;
● Modular design: NVF2 series inverter integrated into the modular design for easy removal Meter, cooling fans and a removable
keyboard, easy to maintain and use;
● Common DC bus design: multiple inverters by way of a common DC bus In parallel, can share the braking energy back, to avoid over-
voltage, and stable single DC bus voltage of the inverter, so that a continuous and stable operation of the device.

2.4 Superior Environmental Adaptability


● Operating ambient temperature of (-10 ~ 40) ℃, good environmental adaptability, when exceeding 40 ℃,derating 1% use for
increase of per 1 ℃;
● Wide input voltage range (15% fluctuation range of 380V ), can be adapted to various types of civil and industrial power;
● The circuit board is used with three anti-paint treatment process and can be adapted to a variety of complex conditions.

> >> 02
Inverter & Soft-Starter
Inverter
3. Multiple features of software

Speed track running Frequency hopping control

Skip specific frequency to prevent vibrations of mechanical


Starting from the free-running motor speed
systems
Not requiring motor speed detector, i.e. automatically introduce
To prevent mechanical vibration system, bypass resonance
the motor under free operation to set frequency.
automatically when running at constant speed.

DC braking at startup Multi-speed operation

Stop and restart the motor under free operation


Run as programmed at set interval of speeds
When running freely, when the turning direction of motor is
Combine as per signal, and run at frequency internally saved.
uncertain, immediately restart after stopping the motor with
Can also realize multi-speed control with PLC or limit switches.
automatic DC braking.

Automatic voltage regulator (AVR) Energy-saving operation

Ensure the output voltage stability during operation of the Automatic operation with maximum efficiency
inverter Depending on the load and speed, test the load current and
When the grid voltage fluctuates, the output voltage of the provide the most efficient voltage to the motor to achieve the
inverter will not vary with fluctuations of grid voltage. most energy-efficient operation.

Automatic current limiting Fault record


Automatically limit the output current to prevent frequent
over-current Automatically store fault information
Automatically adjust when the load fluctuation exceeds the In the event of fault alarm, automatically record fault current,
current limit, and always keep the current within the allowable voltage and fault type, providing reference basis for determining
range. the failure causes.

Torque limit Sleep control pump

Protect the machinery to ensure reliable operation of mechanical Reduce mechanical wear
equipment When little water is used at night, the inverter output frequency
Facilitate protection of machinery because the torque generated is lower than the frequency of sleep, the inverter enters the sleep
by the motor can be controlled within the set value. mode.

Frequency testing PID control

Automatic Process Control


Testing the frequency for brake interlock Perform PID operation inside the inverter, and use the operation
When the output frequency exceeds the set value, output signal result as the frequency instructions for pressure, flow, and air
for interlock control of external device volume and other quantitative control.

Traverse control Suppress overvoltage


Prevent overvoltage fault trip
Wobble up and down with the set frequency as the center
The feature is valid for running under repeated regeneration
The wobbling function is applicable for textile, chemical fiber
state due to crank movement such as presses, and increase or
industry and occasions when traverse or winding function is
decrease the operating frequency and suppress overvoltage
required.
according to the reproduction state.

Fault reset Automatic torque boost

Improve the reliability of continuous operation Enhance the low frequency output torque under V/F control
Even if the inverter detects failure, it will automatically reset after mode
the self-diagnosis, and restart without interrupting the motor For manual /automatic torque boost setting under V / F mode,
operation. Automatic reset for 3 times. which can effectively increase low torque of inverter.

03 > >>
Inverter & Soft-Starter
Inverter
4. Technical data

4.1 NVF2 Inverter Specifications

4.1.1 Mini type


Input voltage level Single-phase 220V
Inverter power (kW) 0.4/TD2 0.75/TD2 1.5/TD2
Applicable motor power (kW) 0.4 0.75 1.5
Rated output current (A) 2.5 4.5 7

4.1.2 Universal (T), fan water pump (P)


Input voltage level Single-phase 220V Three-phase 380V
Inverter power (kW) 2.2/TD2 3.7/TD2 0.4/TS4 0.75/TS4 1.5/TS4 2.2/PS4,2.2/TS4 3.7/PS4,3.7/TS4 5.5/PS4 5.5/TS4
Applicable motor power (kW) 2.2 3.7 0.4 0.75 1.5 2.2 3.7 5.5 5.5
Rated output current (A) 10 16 1.2 2.5 3.7 5 9 11 13

Input voltage level Three-phase 380V


Inverter power (kW) 7.5/PS4,7.5/TS4 11/PS4 11/TS4 15/PS4,15/TS4 18.5/PS4,18.5/TS4 22/PS4,22/TS4
Applicable motor power (kW) 7.5 11 11 15 18.5 22
Rated output current (A) 17 22 25 32 37 45

Input voltage level Three-phase 380V


Inverter power (kW) 30/PS4,30/TS4 37/PS4,37/TS4 45/PS4,45/TS4 55/PS4,55/TS4 75/PS4 75/TS4
Applicable motor power (kW) 30 37 45 55 75 75
Rated output current (A) 60 75 90 110 140 150

Input voltage level Three-phase 380V


Inverter power (kW) 90/PS4,90/TS4 110/PS4,110/TS4 132/PS4,132/TS4 160/PS4,160/TS4 185/PS4,185/TS4 200/PS4,200/TS4
Applicable motor power (kW) 90 110 132 160 185 200
Rated output current (A) 176 210 253 300 340 380

Input voltage level Three-phase 380V


Inverter power (kW) 220/PS4,220/TS4 245/PS4,245/TS4 280/PS4,280/TS4 315/PS4
Applicable motor power (kW) 220 245 280 315
Rated output current (A) 420 470 520 600

> >> 04
Inverter & Soft-Starter
Inverter
4.2 NVF2 standard technology features

Input voltage range: 380V/ 220V(±15%)


Input-output Input frequency range: (47~63)Hz
characteristics Output voltage range: 0 ~ rated input voltage

Output frequency range: Universal type:(0~400)Hz; fan pump type:(0~120)Hz

Programmable Digital Input: Mini: 5-circuit; Universal, fan and pump type: 6-circuit
Programmable Analog Input: AI1: (0 ~ 10) V input; AI2: (0 ~ 10) V or (0/4 ~ 20) mA; AI1 + AI2
Peripheral
Open collector output: 1 output
interface
Relay output: Mini: 1 output; Universal, fan pump: 2-circuit outputs
Analog output: 2-circuit outputs, respectively, optional (0 ~ 10) V or (0/4 ~ 20) mA (Mini type 1-circuit)

Torque boost: Automatic torque boost; manual torque boost of 0.1% -30.0%
Energy consumption braking: internal or external braking unit, an external braking resistor
DC braking: start, stop, respectively, optional, operating frequency (0 ~ 10) Hz, braking current (0 to 150)%,
operating time (0.0 ~ 50.0) s
Jog Control: Jog Frequency range: (0 ~ 400) Hz, jog acceleration and deceleration time (0.1 ~ 3600.0) s
Ope rat ion
fun ction Multi-speed operation: multi-speed run through the built-in simple PLC or control multi-function terminals
cha rac teristics Automatic voltage regulation (AVR): When the grid voltage changes, AVR can automatically maintain constant output voltage
Automatic current limiting: Automatically limit the current during running to prevent fault trip frequently due to over-current
Built-in PID controller: can easily form into closed loop control system
Custom JOG function keys: JOG keys can be set to jog running or switch between forward and reverse operation
Protection: Provides up to 20 kinds of fault protection features: over-current, overvoltage, under-voltage,
over-temperature, phase-lack, overload, PID disconnection and other protection features.

Control: vector control without PG, V / F control


Overload: Mini type and universal type: 150% of rated current 1min; fan & pump: 120% of rated current 1min

Technical Starting torque: Vector control without PG: 0.5Hz/150% (rated torque)
characteristics Speed ratio: vector control without PG: 1:100; V / F control: 1:50
Speed control accuracy: (vector control without PG): ± 0.5% maximum speed
Carrier frequency: (1 ~ 15) kHz

Temperature: Operating ambient temperature between -10 ℃ ~ 40 ℃, when exceeding 40 ℃, derate by 1% per increase of 1℃
Humidity: relative humidity of the air in the operating environment ≤ 95%, non-condensing
Operating Altitude: below 1000m,when altitude is over 1000m, derate by 10% per increase of 1000m
environment
Shock and vibration: Do not install in a place susceptible to frequent shock
Electromagnetic radiation: Install at place away from sources of electromagnetic radiation
Air pollution: Do not install at place of air pollution, such as dust, corrosive gases and other similar environment

Levels of protection: IP20


Structure Brake unit: standard brake unit for models below 22kW, optional brake unit for models 22kW and above
Cooling mode: NVF2 inverter full-range is cooled with high-speed DC fan

05 > >>
Inverter & Soft-Starter
Inverter
5. Wiring diagram

5.1 Standard wiring diagram


5.1.1 Mini-type standard wiring diagram

External braking resistor

Circuit
breaker Contacto r + B
B
-
R U
Power S V
Input M
T W

Motor Grounding
Inverter grounding Main circuit terminals

Control circuit terminals


Multi-f unctio n input 1
X1
Multi-f unctio n input 2
X2
Multi-f unctio n input 3
X3
Multi-f unctio n input 4
X4 AO1 Multi-function analog output
Multi-f unctio n input 5 (0 ~ 10) V or (0/4 ~ 20) mA
X5 GND GND

COM
COM

R1B Multi-function relay output


+10V
R1A Contact output
Frequency setting
AI1 R1C AC 250V below 3A
Resistance regulator
DC 30V below 1A
(0 ~ 10) V
GND
GND

Analog Input AI2


(0 ~ 10) V or Y1
(0/4 ~ 20) mA Open-loop collector output
(DC 24V)
COM

RS485 communication 485+ COM


Modbus communication
protocol 485-

J601 J602 J603

485+ 485- X1 X2 X3 X4 X5 R1C R1B R1A


+10V A12 A11 GND AO1 GND COM Y1 COM +24V

Terminal arrangement of corresponding control


J601 position (AI1 Interface): 1 interface 2: AI1 0V~10V analog voltage input; 2 interface 3: Panel potentiometer input
J602 position (AI2 Interface): 1 interface 2:0V~10V analog voltage input; 2 interface 3:0/4mA ~20mA analog current input
J603 position (AO1 Interface): 1 interface 2:0 V ~ 10V analog voltage output; 2 interface 3:0 / 4mA ~ 20mA analog current output
Corresponding models: NVF2-0.4/TD2 ~ NVF2-1.5/TD2
Note: Single-phase inverter main power cord interface R and T terminals.

> >> 06
Inverter & Soft-Starter
Inverter

5.1.2 Standard wiring diagram for universal type, fan and pump type

External braking
DC reacto r resistor

Circuit
Contacto r
breaker +2
+1 B
B
-
R

R U U

Power S

S V V

Input T

T W
W
M

Motor Grounding
Inverter grounding Main circuit terminals

Control circuit terminals


Multi-f unctio n input 1 X1 AO1 Multi-function analog output
Multi-f unctio n input 2 X2 (0 ~ 10) V or (0/4 ~ 20) mA
Multi-f unctio n input 3 X3
Multi-f unctio n input 4 X4
AO2 Multi-function analog output
Multi-f unctio n input 5 X5
GND (0 ~ 10) V or (0/4 ~ 20) mA
Multi-f unctio n input 6
GND

X6
COM
COM

R1B Multi-function relay output 1


R1A Contact output
R1C AC 250V below 3A
+10V
Frequency setting DC 30V below 1A
Resistance regulator AI1
(0 ~ 10) V R2B Multi-function relay output 2
GND
GND R2A Contact output
R2C AC 250V below 3A
DC 30V below 1A
Analog Input AI2
(0 ~ 10) V or
(0/4 ~ 20) mA
Y1

Open-loop collector output


RS485 communication 485+
(DC 24V)
Modbus communication
485-
COM

protocol COM

J601 J602 J603 J604

485+485- X1 X2 X3 X4 X5 X6 Y1 COM R2A R2B R2C


+10V A12 A11 GND AO1 AO2 GND COM +24V R1A R1B R1C

Terminal arrangement of corresponding control


J601 position (AI1 Interface): 1 interface 2: AI1 of 0V ~ 10V analog voltage input; 2 interface 3: Panel potentiometer input
J602 position (AI2 Interface): 1 interface 2:0 V ~ 10V analog voltage input; 2 interface 3:0 / 4mA ~ 20mA analog current input
J603 position (AO1 Interface): 1 interface 2:0 V ~ 10V analog voltage output; 2 interface 3:0 / 4mA ~ 20mA analog current output
J604 position (AO2 Interface): 1 interface 2:0 V ~ 10V analog voltage output; 2 interface 3:0 / 4mA ~ 20mA analog current output
Corresponding models: NVF2-0.4/TS4 ~ NVF2-280/TS4; NVF2-3.7/PS4 ~ NVF2-315/PS4
NVF2-2.2/TD2 ~ 3.7/TD2
Note: Single-phase inverter main power cord interface R and T terminals.

07 > >>
Inverter & Soft-Starter
Inverter
5.2 Terminals annotation
5.2.1 Main circuit terminals annotation

Terminal Symbol Terminal name and description


R,S,T AC power input ter minal ,co nne ct ed to the thr ee -pha se 380V power suppl y (220V singl e- pha se co nne ct ion R, T)
⊕1, Θ DC power input terminal, externally connected to braking unit
⊕1,B Connect the brake resistor terminals
⊕1 ,⊕2 DC reactor connection terminals
U,V,W AC output terminal connected to the motor
Ground terminal, for grounding inverter

5.2.2 Control circuit terminals


Terminal Symbol Terminal name Explanation
R1A,R1B,R1C RA, RB are normally open contact groups, RB, RC are normally closed contact group,
Relay contact output
R2A,R2B,R2C The function parameters are set from F6.01, and F6.02.
Function parameters are set from F6.00,
Y1,COM Open collector output
the factory settings are forward state signal outputs.

485+,485- Terminals in serial communication with external


Serial communication terminal
Frequency setting power supply Connecting to potentiometer in resistance of 4.7kΩ ~ 10kΩ
10V
together with AI1, AI2, and GND.

Connecting to potentiometer or 0V ~ 10V signal,


AI1,GND Analog signal input terminal
used as frequency setting, PID given or feedback
AI2,GND Analog signal input terminal Input 0V ~ 10V, 0/4mA ~ 20mA signal, as the frequency setting, PID given or feedback.
Analog signal form for AO1, AO2 connected to DC 10V or 0/4mA ~ 20mA,
AO1,AO2 Analog signal output terminal
can be used to indicate the operating frequency, Output current, output voltage, etc.

X1 Multi-function input terminal The factory setting is forward operation.


X2 Multi-function input terminal The factory setting is reverse operation.
X3 Multi-function input terminal The factory setting is forward jog.
X4 Multi-function input terminal The factory setting is reverse jog
X5 Multi-function input terminal The factory setting is fault reset
X6 Multi-function input terminal The factory setting is external fault input

Multi-function input terminal


COM Use with X1 ~ X6
common ground
24V,COM Auxiliary power 24V output 24V DC power output (≤ 50mA)

6. Overall and mounting dimensions (mm)

6.1 Product Outline Drawing


NVF2 display box opening size

25
73.5(W1)
63
15.6

RUN/PRG F/R LOC/REM FAULT Hz A V


111.5

93

JOG - +
SHIFT
<

PRG SET
<

RUN STOP

Panel cutout dimensions

> >> 08
Inverter & Soft-Starter
Inverter

NVF2-0.4/TD2 ~ 3.7/TD2 and NVF2-0.4/TS4 ~ 11/PS4

H1
H
W1 4Xd D1
W D

NVF2-11/TS4 ~ 220/PS4
H1
H

D1
W1 4Xd
W D

NVF2-220/TS4 ~ 315/PS4

W D W1 W1
H1
H

D1

09 > >>
Inverter & Soft-Starter
Inverter
6.2 Product mounting dimensions

Mounting Dimensions Weight


Model
W H D W1 H1 D1 d kg
Display Box 74.5 111.5 25
NVF2-0.4/TD2
NVF2-0.75/TD2 85 154 114 76 142 105 5 0.9
NVF2-1.5/TD2
NVF2-0.4/TS4
NVF2-0.75/TS4(1.5/PS4)
NVF2-1.5/TS4(2.2/PS4)
118 187 173 107 175 110 5 3.1
NVF2-2.2/TD2
NVF2-2.2/TS4(3.7/PS4)
NVF2-3.7/TS4(5.5/PS4)
NVF2-3.7/TD2
NVF2-5.5/TS4(7.5/PS4) 155 247 189 140 232 125 6 3.6
NVF2-7.5/TS4(11/PS4)
NVF2-11/TS4(15/PS4) 194 381 270 140 366 142 7 10
NVF2-15/TS4(18.5/PS4)
222 426 290 140 412 178 7 14
NVF2-18.5/TS4(22/PS4)

NVF2-22/TS4(30/PS4)
300 596 345 210 568 210 8 27
NVF2-30/TS4(37/PS4)
NVF2-37/TS4(45/PS4)
NVF2-45/TS4(55/PS4) 355 691 395 280 664 220 8 45
NVF2-55/TS4(75/PS4)
NVF2-75/TS4(90/PS4)
380 750 410 300 716 190 9 60
NVF2-90/TS4(110/PS4)
NVF2-110/TS4(132/PS4)
485 920 445 400 880 230 12 115
NVF2-132/TS4(160/PS4)

NVF2-160/TS4(185/PS4)
NVF2-185/TS4(200/PS4) 590 1080 475 450 1040 233 12 160
NVF2-200/TS4(220/PS4)
NVF2-220/TS4(245/PS4)
NVF2-245/TS4(280/PS4) 710 1010 385 250 968 410 13 165
NVF2-280/TS4(315/PS4)

7. Optional parts for peripherals


Descri pti on of opti onal parts Function of optional parts

Protect the power system in the event of short circuit accident.


Circuit breaker for wiring Make sure connection between the AC mains supply and AC reactor,
and where there is no reactor, connect to the front of the inverter.

Improve the input power factor, reduce the high harmonics,


AC input reactor
and suppress the surge on the power device of the inverter.

1. Improve or suppress the distortion rate of grid voltage and current waveforms due to the pulse
DC reactor current discharged by filter capacitor;
2. Reduce the harmonic content and improve the quality of power supply from grid.

1. Can effectively suppress the noise level vibration of the motor;


AC output reactor 2. Can effectively suppress differential mode noise within 100KHz on the output side of the inverter;
3. Can effectively absorb the surge voltage.

1. Control the boost of bus voltage pump, forming certain protective effect to the inverter;
Brake unit
2. When frequent braking is required, the braking capability of the inverter can be improved.

Can consume the mechanical energy from motor braking in the form of heat through braking resistor,
Braking resistor
and shorten the deceleration time of inverter drive system.

When the operation panel of inverter needs to be installed on the door panel of control cabinet,
Keyboard tray
or requires operation cabinet for remote control, keyboard tray is required for installation.

Display extension cable Use as extension cable when using remote control or outside pulling of the operation panel.

> >> 10
Inverter & Soft-Starter
Inverter
Optional accessories form

Brake attachment options AC input reactor AC output reactor DC reactor


Inverter Braking resistor

Configuration

Configuration
Brake unit
Rated Rated Rated
configuration Inductance Inductance (mH)
Power Current Current Configuration Current
(10% braking Resi st an ce (mH) (mH) Inductance
NVF2-□/□□□ un it( Ω) (W) (A) (A) (A)
rate)

0.4/TD2 Standard 220 80 2.4 4.6 2.4 4.5 — —


0.75/TD2 built-in 220 80 4.5 2.4 4.5 2.3 — —
1.5/TD2 brake unit 100 260 7 1.6 7 1.5 — —
2.2/TD2 70 260 11 1 11 0.9 — —
3.7/TD2 40 390 18.5 0.6 18 0.5 — —
0.4/TS4 750 80 2.5 2.83 3 2.1 — —
Without
0.75/TS4 Braking unit 750 80 3.7 2.239 3 2.1 — —
requiring
1.5/PS4,1.5/TS4 standard 400 260 3.7 2.239 3 2.1 purchase of — —
2.2/PS4,2.2/TS4 built-in 250 260 5.5 2.18 6.3 1.5 DC reactor — —
3.7/PS4,3.7/TS4 (including 150 390 9 1.85 11 1.1 — —
22/PS4
5.5/PS4,5.5/TS4 100 520 13 1.56 16 0.8 — —
models)
7.5/PS4,7.5/TS4 75 780 18 1 18 0.65 — —
11/PS4,11/TS4 50 1040 24 0.52 28 0.33 — —
External optional

External optional
15/PS4,15/TS4 40 1560 34 0.397 35 0.25 — —
18.5/PS4,18.5/TS4 32 4800 38 0.352 40 0.2 — —
22/PS4,22/TS4 27.2 4800 50 0.26 50 0.18 70 0.9
30/PS4,30/TS4 Built-in 20 6000 60 0.24 63 0.09 80 0.86
Built-in
37/PS4,37/TS4 braking unit 7000 75 0.235 80 0.08 100 0.7
16 optional
optional
45/PS4,45/TS4 13.6 9600 91 0.17 100 0.06 (including 120 0.58
(including
55/PS4,55/TS4 10 12000 112 0.16 125 0.04 110/PS4 146 0.47
110/PS4
models)
75/PS4,75/TS4 models) 6.8 12000 150 0.12 160 0.035 160 0.36
90/PS4,90/TS4 6.8 12000 200 0.0705 200 0.023 180 0.33
110/PS4,110/TS4 6 20000 224 0.0692 224 0.016 250 0.24
132/PS4,132/TS4 6 25000 280 0.0503 280 0.016 Standard 280 0.24
built-in
160/PS4,160/TS4 2.5 50000 315 0.0447 315 0.013 340 0.16
185/PS4,185/TS4 External 400 0.0352 400 0.011 460 0.09
200/PS4,200/TS4 brake unit 400 0.0352 400 0.011 460 0.09
220/PS4,220/TS4 optional 450 0.0313 560 0.009 500 0.82
Standard
245/PS4,245/TS4 560 0.0251 600 0.008 600 0.072
external
280/PS4,280/TS4 560 0.0251 600 0.008 600 0.072
315/PS4 640 0.0224 690 0.006 700 0.068

Corresponding
physical drawing
of each accessory

showing
showing
Physical drawings extension
box pallets
showing extension cable
cable and showing
box pallets

Note: If the inverter panel needs to be externally pulled for operation control, the user needs to specify when ordering,
and indicate the length of the extension cord displayed.

11 > >>
Inverter & Soft-Starter
Inverter
8. Ordering information
8.1 Type designation
NVF2-□/□ □ □

Voltage class: 2: 220V series; 4: 380V series

Input voltage: D: single-phase input;


S: three-phase input

Type: T:universal type ;


P: fan and pump type

Matching motor (kW)

Design sequence No.

Inverter

Company code

When ordering, please select the desired models and specifications in accordance with the instructions on models and
meaning,:
For example:
Single phase 220V series: NVF2-0.75/TD2
Three-phase 380V universal: NVF2-45/TS4
Three-phase 380V fan & pump: NVF2-55/PS4
8.2 Guide for Model Selection
8.2.1 In order to ensure reliable operation of the inverter, the inverter power must be greater than or equal motor power.
8.2.2 The universal inverter is mainly used for load other than fans and pumps, such as: rolling mill, mixer, ball mill,
centrifuges and other heavy loads.
8.2.3 The fan & pump inverter is mainly used for light load e.g. fan and pump.

9. Customized VFC control cabinet


A variety of VFC control cabinets can be specially ordered according to the production process requirements.

> >> 12