You are on page 1of 10

Sluice room

Intensive Kitchen
Baby care 2

Emergency Exit

Isolation section
Pastueriser
Freezer $ Fridge
DN Oxygen cylinders' storage

Pastuerisation
Area
Epoxy flr fin'
25 m²
Work-top table

Beds
Freezers & Fridge

A2-L1
1 WHB Work-top/shelves below

Lobby
Beds
Tiles Flr fin'
2 m²

1-
A3A2-P1
PORT
---
Circulation
E1

POrcelain tiles flr fin' Kangaroo Mothers'


Expression Room 10 m²
Porcelain tiles flr' area
11 m² Donor's gowns

E1

-
---
Mother's
Changing Room
? gowns
4 m²

Milk Dispatch
?
5 m² Counselling
?
6 m²

Main
entrance
Reception
?
5 m²

Bath

Bath Room

Rest Room

NEW PLAN
1 1 : 65

Client Name Nsambya Hospital Designed and drawn by: K-Daniel


Project Drawing Title Drg. No. A1-P1
Nsambya Hospital Breast Milk Bank
Contact +256 414 267 012
<Address> Kajjubid1@gmail.com Scale Date
<Project Address> Facility Breast milk Bank
Project number P-0l-NSB-2020 1 : 65
<Contact> 0758843773 01/31/20
3/13/2020 3:14:29 PM
4400mm of existing
wall wall length to
be demolished to
ring beam level

1000mm of existing
wall to be demolished
to ring beam level

Existing double shutter


door to be removed
100mm of existing
wall to be demolished
to a height of 2400mm
to create facility
Staff
Changing
entrance

Drug
store Dr's room

Existing door to be
ENTRANCE removed and switched
In-charge position

900mm length wall


opening to be created
to accomodate the door

DEMOLISHED PLAN DETAILS - Callout 1


1
1 : 50

DESIGNER Project Drawing Title Scale Date Drg. No.


Nsambya Hospital Breast Milk Bank 1 : 50 03/13/20 A2-P3
K.DANIEL DEMOLITION PLAN
<Address> Drawn By

<Contact No.> NSAMBYA HOSPITAL Author

3/13/2020 3:14:49 PM
Pastueriser
$ freezer

DN
Freezers

Instruments

Freezers
and Utensil Pastueristion Space
cleaning Staff work-top

Freezers
(Autoclave below)
Pastueriser
Emergency control point and
exit dispatch
Wash hand
basin with bin
below Fire extinguisher

changing

Kangaroo
mothers

Wash hand basin

Expression area Mothers'


Changing gowns

Room Legend
Changing Counselling
Milk-
Changing Room dispatch

Circulation
Counselling
Enquires
ENTRY
Expression Room Reception
Gas store
Lobby
Milk Dispatch
Pastuerisation Area
Reception
FACILITY PLAN
1
1 : 60

Designer: Drg. No.


Kajjubi Daniel Nsambya Hospital Breast Milk Bank A3
PORT
Drg. Title Client"s Name Date
Address: Kajjubid1@gmail.com 01/31/20
FACILITY DETAIL NSAMBYA HOSPITAL Scale 1 : 60
3/13/2020 3:14:53 PM
6370

200 2300

200

740
810

1000
DN
Gas store
Concrete screed flr fin' Freezers Freezers
2 m²

150
2450 1620 150 1760
concrete worktop
W2
finished with

2620
coldformed mild

4310
Pastuerisation
steel
Area
with shelves below Epoxy flr fin' 700
W2 800 25 m²
4440

3870

150
880 150 1750 150 1350 1700

800
600 200

200
1010
9700

580
D1 Dispatch work top
finished with
200

1
1470 900 410 D2 treated hard-wood
610

W1
A2-L1 Lobby with shelves below

1220
Tiles Flr fin'
2 m²

3440
800
880

Expression work top W1


finished with treated Changing
290

hard-wood Tiles Flr fin'


Expression Room 1 m²
4080

Porcelain tiles flr'


610 220 610

W1 11 m²
1850

120
3200
767 Circulation
800 POrcelain tiles flr fin'
W1 D1 10 m² 2800mm high aluminium
150 framed partition with

980
1800 1060 150 2820 D1
fixed obscured glazing
1020

500
200

870 200 2130 150 1120

Mothers'
gowns
Changing

120
Room Legend
910

Milk-

Counselling
dispatch
Changing
Changing Room
Circulation 1050 800
3540

Counselling
Enquires
Expression Room Reception
Gas store
910

Lobby
220

Milk Dispatch
Pastuerisation Area
Reception

FACILITY PLAN . Copy 1


1
1 : 50

DESIGNER Project Drawing Title Scale Date Drg. No.


Nsambya Hospital Breast Milk Bank 1 : 50 03/13/20 A2-P1
K.DANIEL DETAILED PLAN
<Address> Drawn By

<Contact No.> NSAMBYA HOSPITAL Author

3/13/2020 3:14:37 PM
- EXISTING ROOF
---

SUSPENDED CIELING FINISH CIELEING

EXISTING WALL

WOODEN TRUSSED ROOF


SYSTEM TO BE REPLACED
ROOF LEVEL ROOF LEVEL
2700 2700

100

720
FIXED TOP LIGHT IN ALUMINIUM
900

100
670
FRAME AND CLEAR GLASS
W2
900

Expression work top W1 DISPATCH WINDOW


450

2680
finished with

2150
D1

2100

2100
treated hard-wood
D2

70
510
1060

1060
Storage
850

FLOOR LEVEL FLOOR LEVEL


0 0

GROUND LEVEL

Section 1
1
1 : 25

Epoxy Cement/Mortar
Emulsion Paint for exterior walling. MILD STEEL
Ceiling Boards
Epoxy Without hardener Cast mild steel to profiles as
1.5mm to 7mm thick three Apply one mist coat and 2/3 shown on the Architects drawings.
Gypsum Plasterboard finishing coats of matt exterior All mild steel to be carefully
800x800mm grid plasterboard component solvent free cementitious
light coloured epoxy modified self Emulsion from plascon paints. milled and all blemishes, joints,
feather edged/butt jointed with Application to be in accordance angles carefully worked to an even
scrim joint filler and taped finish leveling floor topping on cement
sand screed (1:3) mix. Total with Manufacturer surface.
fixed galvanized mild steel
channels/ 50mm x 50mm treated thickness 12mm,continuous to 200mm
softwood battens at 600mm centers. skirting level on all walls around
Ceiling 2700mm above finished floor the pasteurisation area. New Hardwoods
level. Ensure the wood is dry. Prime all
Porcelain Tiles joints, tendons, grooves, tongues,
600mm x 600mm x 8mm thick Emulsion Paint for internal walling
end grains (where porous apply
un-glazed/ non-slip porcelain second coat of Primer) and meeting
tiles with continuous joints Apply one mist coat and 2/3 surfaces during assembly. Sandpaper
not exceeding 6mm wide in both finishing coats of matt silk smooth and finely round-off sharp
directions, fixed with adhesive vinyl from plascon paints, edges. Dust off. Oily timber to be
on cement sand screed (1:3) Application to be in accordance thoroughly wiped clean with a cloth
mix, jointed and flush pointed with Manufacturer dipped in white spirit and allowed
with tinted flexible grout. to dry.
Total thickness 8mm
SPECIFICATIONS
1 : 20

Designer: Drg. No.


Nsambya Hospital Breast Milk Bank
A2-L1
Drg. Title Client"s Name Date
Address: 02/28/20
SECTION NSAMBYA HOSPITAL Scale
As
indicated
TYPE ILLUSTRATION NUMBER POSITION DESCRIPTION
900
FIXED GLASS WINDOW
PASTEURISATION
2 AREA • Aluminium powder

900
W2 coated framed window
with fixed clear
mirrored glass
610 TOP-HUNG GLASS WINDOW
EXPRESSION AREA • Aluminium powder
4
280

coated framed window


900

W1 with top hung operable


620

clear mirrored glass

TYPE ILLUSTRATION NUMBER POSITION DESCRIPTION

PASTEURISATION
1 AREA • Aluminium powder
290

D2 coated framed double


760

door with fixed wired


2100

glass light entrant


1060

970 540

1510

EXPRESSION • Aluminium powder


D1
260

AREA,PASTEURISATION coated framed single


AREA,GAS door with fixed wired
4
STORE,CIRCULATION glass light entrant
1510

2100

AREA.
330

540 220
160

910

schedules
1 : 50

GENERAL NOTES

• All wash hand basins and sinks to be supported on


75mm thick cast concrete toping with wooden
storage shelving below in the expression area and
mild steel shelving in the pasteurisation area.

• Plinth walls on the exterior wall to be finished


with Fine chisel dressed stone on cement mortar
(1:4) mix on cement sand screed (1:3) mix. Total
thickness 40mm thick.
• Facility roof to be supplied with galvanised or pvc
rain gutter.
• All facility sinks are to be connected to an
exterior soak pit to contractor's shop drawings.

DESIGNER Project Drawing Title Scale Date Drg. No.


Nsambya Hospital Breast Milk Bank 1 : 50 03/13/20 A2-P2
K.DANIEL SCHEDULES AND NOTES
<Address> Drawn By

<Contact No.> NSAMBYA HOSPITAL Author

3/13/2020 3:14:44 PM
BABY UNIT

PASTUERISATION

BEDS
EXPRESSION

LOBBY

PLAN VIEW
1

Designer: Drg. No.


Nsambya Hospital Breast Milk Bank A3
LAND 4
Drg. Title Client"s Name Date
Address: 02/28/20
3/13/2020 3:16:40 PM
TOP CUT-AWAY NSAMBYA HOSPITAL Scale
100MM DEEP R.C BEAM

SUSPENDED CIELING

TOP FIXED ALUMINIUM


FRAMED LIGHT ENTRANTS
200MM HIGH150MM THICK
BRICK WALLS

PASTUERISATION AREA

DONORS' LOBBY STAFF LOBBY

PASTUERISER

APPROVED FLOOR
FINISH

FREDGE AND FREEZER


LONGITUDINAL SECTION
1

Designer: Drg. No.


Nsambya Hospital Breast Milk Bank A3
LAND 1
Drg. Title Client"s Name Date
Address: 02/28/20
3/13/2020 3:16:32 PM
LONGITUDINAL SECTION NSAMBYA HOSPITAL Scale
200MM HIGH150MM
THICK BRICK WALLS

TOP FIXED ALUMINIUM


FRAMED LIGHT ENTRANTS

DONORS' EXPRESSION STAFF LOBBY


AREA

lOCKERS
CURTAIN PRIVACY BLINDS

EXPRESSION TOP
CROSS-SECTION
1

Designer: Drg. No.


Nsambya Hospital Breast Milk Bank A3
LAND3
Drg. Title Client"s Name Date
Address: 02/28/20
3/13/2020 3:16:05 PM
CROSS-SECTION NSAMBYA HOSPITAL Scale
DESIGNER Project Drawing Title Scale Date Drg. No.
Nsambya Hospital Breast Milk Bank 03/15/20 A2-P4
K.DANIEL renders
<Address> Drawn By

<Contact No.> NSAMBYA HOSPITAL Author

3/15/2020 9:17:39 AM