Professional Documents
Culture Documents
MARKET SELECTION
INDUSTRY
MARINE
FIRE PROTECTION
UK PROTECTIVE
COATINGS
We Know...
Protective &
Marine Coatings
PROFESSIONALS IN PROTECTION
Language Selection
English
Dutch
French
Russian
> START
We Know...
Fire Protection
Coatings
PROFESSIONALS IN PROTECTION
Language Selection
English
We Know...
Fire Protection
Coatings
PROFESSIONALS IN PROTECTION
> START
We Know...
Fire Protection
Coatings
PROFESSIONALS IN PROTECTION
Cementitious Coatings
Steelguard CM 4701
Steelguard CM 4702
Steelguard CM 4703
Steelguard CM 4704
Steelguard CM 4705
Steelguard CM 4706
> START
We Know...
Fire Protection
Coatings
Amercoat
Steelguard CM 4701
Spray Applied Fire Resistant Tunnel Coating
Product Data/
Application Instructions Physical Data
Appearance ............................ sprayed textured finish, usually
trowelled to close the surface
• Passive fire protection for use in tunnels
• Spray applied Colour .................................... off white
• Durable, impact resistant Components ........................... 1 (excluding water/additives)
• Modified vermiculite cement
3
• Tested to meet recognized international tunnel Dry density of the powder....... 465 kg/m
standards 3
Nominal dry density applied ... 725-775 kg/m
• Most fire ratings achieved in one single application
• Top coat systems to meet required colour and VOC ....................................... 0 g/l
reflectance levels
Curing mechanism ................. Hydrolisation
• Easy clean top coats
• Up to 4 hours insulation Thickness requirements ......... Contact PPG for details
Approvals
Steelguard CM 4701 is tested to resist fire conditions
in tunnels meeting recognized international tunnel
standards including the RATB in Germany,
Eurocode’s 1, 2 & 3 (EN 1991-1-2; EN 1992-1-2 & EN
1993-1-2) and the Dutch Rijkswaterstaat in
cooperation with the TNO Institute using the ‘RWS
97-CVB-R0710 Hydrocarbon time/temperature curve.
Project specific tunnel fire test may be required.
For suitable tunnel system specification contact PPG
for details.
Application Equipment
Use a mechanical piston or rotor stator type pump equipped
with a high-pressure plaster type hose avoiding brass or
aluminium type couplings. The flexible hose length should not
exceed 100 meters, with following typical length.
I.D. 75 mm (3”) maximum 100 meters
I.D. 50 mm (2”) maximum 50 meters
I.D. 35 mm (1 ½ ”) maximum 15 meters
I.D. 30 mm (1 ¼ ”) maximum 8 meters
For longer lengths use metal pipe with a I.D. of 65 -75 mm
Use as spray nozzle assembly a minimally 25-32 mm nozzle
with a 10 to 13 mm nozzle orifice and a rubber blow-off cap.
Atomising air should be 2-4 bar (28-57 psi) at the nozzle.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance ............................ sprayed textured finish, usually
trowelled to close the surface
• Passive fire protection for use in refineries and tank
storage facilities, in industrial and chemical plants and Colour .................................... grey
on offshore platforms.
• Meets international hydrocarbon fire standards Components ........................... 1 (excluding water/additives)
• Spray applied Dry density of the powder....... 465 kg/m
3
levelling by trowel this can be achieved by spray application At the end of the spray line 1050 – 1200 kg/m
3
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance ............................ sprayed textured finish, usually
trowelled to close the surface
• Passive fire protection for steel framed structures
• Spray applied Colour .................................... light grey
• Durable, impact resistant Components ........................... 1
• Modified vermiculite cement
3
• Up to 4 hours fire protection of structural steel Nominal dry density ............... 725-775 kg/m
• Most fire ratings achieved in one single application VOC ....................................... 0 g/l
• Excellent weathering resistance meeting upto ISO
12944 C5M requirements. Curing mechanism ................. Hydrolisation
levelling by trowel this can be achieved by spray application At the end of the spray line 1050 – 1200 kg/m
3
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance ............................ sprayed textured finish, usually
trowelled to close the surface
• Passive fire protection for steel framed
structures Colour .................................... grey
• Spray applied Components ........................... 1
• Robust coating for internal C1/C2
3
environments (ISO 12944) Nominal dry density ............... 350-400 kg/m
• Modified vermiculite cement VOC ....................................... 0 g/l
• Up to 4 hours fire protection of structural steel
• Most fire ratings achieved in one single Curing mechanism ................. Hydrolisation
application Loading requirements: In order to establish the thickness required
to give the specified fire resistance, reference should be made to
the products Hp/A (A/V) values or limiting temperature tables.
Typical Uses Contact your PPG representative for full details.
Steelguard CM 4704 is a tough hard and highly stable
passive fire protection for use on internal structural steel. Nominal usage at 25 mm thickness
The spray-applied coating shows excellent mechanical Per 25 kg sack........................ 2.65 m
2
resistance. It does not rely on any form of expansion, Per tonne................................ 106 m
2
levelling by trowel this can be achieved by spray application At the end of the spray line 900 – 1050 kg/m
3
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance ............................ clear when dry
• Additive for modified Steelguard CM Colour .................................... milky white liquid
vermiculate cement coatings
Components ........................... 1
• Adhesion promoter in bonding coat
• Improves substrate adhesion Specific gravity ....................... 1.08 kg/l
• Improves cohesive strength
pH........................................... 4.5 – 5.5
• Improves early water resistance
Volume solids ......................... 50% ± 2%
Application Procedure
Steelguard CM 4705 must be thoroughly stirred Application Data
before used. Thinner .................................. Do not thin
Shipping Data
Pack size ................................ 25 litre pails
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions
• Sealer coat for alkyd, unknown primers Physical Data
• Prevents primer saponification
• Adhesion promoter for primed steel Appearance ............................ matt
Theoretical coverage at 50
microns dry film thickness ..... 5.4 m²/litre
Surface Preparation
Ensure that the existing coating is clean, dry, sound Application Data
and free from any dirt, dust or contamination Substrate ................................ coated steel
immediately before coating. Any loose adherent
coating should be removed back to firm edge and Application method................. brush, roller, airless and
conventional spray
suitably patch repaired.
Environmental Conditions
Ambient temperature .......... 5 to 25°C 41 to 77ºF
Mixing Surface temperature: ........... 4°C/39ºF minimum
Steelguard CM 4706 must be thoroughly stirred
before use. Surface temperature must be at least 2°C/4°F above the dew point
to prevent moisture condensation on the surface.
Shipping Data
Pack size ................................ 25 litre pails
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Intumescent Coatings
> START
We Know...
Fire Protection
Coatings
Amercoat
®
Pitt-Char XP
Epoxy Intumescent Coating
Product Data/
Application Instructions Physical data
Finish...................................... glossy
• Superior fire & corrosion protection
Colour..................................... grey
• Unique flexibility
• Superior mechanical resistance Components ........................... 2
• Suitable for cryogenic exposure
Mixing ratio
• Complies with international fire standards By volume ............................ 2.33 part A to 1 part B
By weight ............................. 3.25 part A to 1 part B
Typical uses
Pitt-Char XP epoxy intumescent coating offers Curing mechanism ................. Chemical reaction between
components
outstanding fire protective properties. When exposed
to fire, its unique chemical composition transforms its Weight solids .......................... 100%
surface into ceramic-like, insulating char that provides
VOC*
thermal protection for the substrate even under EC SED 1999/13/EC ........... 0 g/kg (0 g/l)
hydrocarbon and jet fire conditions. UK PG6/23(92) Appendix 3 . 0 g/l (0 lbs/gal)
Because Pitt-Char is an epoxy, its tough, durable
Dry film thickness ................... Dependant on fire rating and
coating provides a dense shield to the elements. Pitt- loading factors
Char XP has resistance to solvents, acids, alkalies,
salts and abrasion making Pitt-Char the idea choice Wet film thickness per coat .... 6-8 mm (0.25-0.30”)
for harsh environments ranging from arctic to tropical Typical coverage
climates. For service applications exceeding 80°C 2
At 5 mm/0.2” ..................... 0.25 m /l
2
10.33 ft /gal
(176°F) consult your PPG Protective & Marine 2
At 10 mm/0.4” ...................... 0.12 m /l
2
5.17 ft /gal
Coatings representative. Pitt-Char coatings have
Flashpoints .............................
successfully protected substrates in refineries, Cure ..................................... over 100°C (212°F)
chemical plants, offshore platforms, and a variety of Resin.................................... over 100°C (212°F)
other ‘high risk’ industrial facilities all over the world. Thinner Type 47................... 44°C 111°F
Amercoat 12 ........................ 24°C 75°F
Amerrcoat 920 ..................... 24°C 75°F
Product fire test results
Thinner ................................... Thinner Type 47
Pitt-Char coatings have been fire tested at more than
12 fire testing facilities around the world. Our products Roller finish solvent** ............. Amercoat 920
have received approvals and certificates from Cleaning solvent..................... Amercoat 12
Underwriters’ Laboratories Inc. (USA and Canada),
Det Norske Veritas (Norway), Lloyd’s Registry (UK), * VOC figures are quoted according to both the EC directive
GASAFE (France), and from several customers 1999/13/EC which are theoretically calculated figures and the UK
PG6/23(92) Appendix 3 which are practically determined figures.
based on their own in-house fire testing. Testing has
covered a range of heat fluxes including jet fire ** Amercoat 920 can be used to wet rollers required to treat
inpingement testing on various steel section sprayed surfaces. It may not be used to thin material for appliaction
improvement.
geometries and sizes. A sampling of fire test results
are listed. For additional test information, including
actual explosion testing up to 1.8 bar average over
pressures and 3.0 peak over pressure, consult your
local PPG Protective & Marine Coatings
representative.
Environmental properties
Test conducted by Underwriters laboratories Inc. (UL) to ensure
retention of fire protection (UL 263 and UL 1709 test criteria)
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance when dry ........... matt
• Thin film solvent based intumescent Colour..................................... white
• Tested to international fire test standards
Components ........................... 1
• Up to 2 hours fire protection of structural steel
• Off-site or on-site application Volume solids* ....................... 68 ± 3%
• Up to 1.5 mm dry film thickness application in a
VOC**
single coat
EC SED 1999/13/EC ........... 293g/kg (378 g/l)
• Rapid job completion UK PG6/23 (92) Appendix 3 325 g/l (2.7 lbs/gal)
• For use in C1 & C2 internal environments – no
sealer coat required for dry internal C1 service Curing mechanism ................. solvent release
conditions (ISO 12944) Loading requirements............. In order to establish the dry film
thickness required to give the
specified fire resistance reference
Typical Uses should be made to the products
Intumescent fire protection for internal structural steel. -1
A/V m (Hp/A) or limiting
Steelguard FM 549 is suitable for on-site or off-site temperature tables. Contact your
application. ppg representative for full details.
Dry film thickness (μm) .......... 250 400 500 700 1000 1500
Approvals
Steelguard FM 549 has been tested to British Standard 476 Wet film thickness (μm) ......... 370 590 740 1030 1470 2205
Part 21 and UK assessed by Warrington Fire. Appraised by 2
Theoretical coverage (m /l) …. 2.72 1.70 1.36 0.97 0.68 0.45
the UK ASFP technical committee and approved for entry in
the Yellow Book. Steelguard FM 549 has been assessed in (wet film thicknesses quoted are theoretical for one airless spray
accordance with the Dutch standard NEN 6072:2001 and coat)
also been assessed and certified to several national fire test
standards. Specific gravity ....................... 1.3 kg/l.
Flashpoint
(closed cup) ......................... ºC ºF
Mixing Steelguard FM 549 .............. 25 77
Stir thoroughly before use until the product is uniform Amercoat 65 ........................ 24 75
throughout. This may cause an apparent thinning effect
which is normal for this product. A power mixer should be *Volume Solids is measured in accordance with ASTM D2697
used. modified. Slight variations of up to ±3% may occur due to testing
variances.
APPROVED PRODUCT
CF 459
Surface Preparation
Applied over a blasted and suitably primed steel substrate. The Application Data
surface must be dry and free of dust, salts, grease and other
contaminants immediately before coating. The primer used should Substrate ................................ primed abrasive blasted steel
be applied in accordance with the specific technical data sheet
instructions, and must be approved by PPG to ensure compatibility Application methods ............... airless spray, brush
with the Steelguard FM 549. The total dry film thickness of primer
Pot life ................................... not applicable
coats should generally not exceed 150 μm. For epoxy primers the
maximum allowable dry film thickness may be extended, consult Environmental conditions
your PPG representative prior to intumescent application.
Relative humidity .................... up to 85%
Surface temperature............ 5 - 50°C 41 - 122 °F
Application Methods Air temperature .................... 5 - 50°C 41 - 122 °F
Spray application will provide the smoothest finish. Brush
application will result in a textured finish. Surface temperature must be at least 3°C/5°F above the dew point
AIRLESS SPRAY - Use a pump capable of producing a minimum to prevent moisture condensation on the surface.
pressure at the tip of 2800 psi (200 kg/cm²). A 30 mesh/ 500 μm
internal filter is recommended. Tip size 19-25 thou’ (0.48-0.63mm). Potlife ................................... not applicable
Dry film thickness of initial coat should not exceed 1.5 mm.
Subsequent coats may be applied after 8 hours at 20°C/68°F to a Thinner .................................. not normally necessary
maximum dry film thickness of 1.0 mm per coat. Amercoat 65 can be used when needed (up to 5% by volume),
BRUSH - Apply evenly using a clean, well-loaded brush at up to However wet/ dry film measurement result will differ & lower max
300 μm dry film thickness per coat. As a guide allow at least 2 film build as result will have to be considered.
hours drying at 20°C/68°F between coats.
Cleaner .................................. Amercoat 65
Overcoating
The standard recommended topcoat for Steelguard FM 549 is
Steelguard 2458 which allows for fast overcoating and job
completion. Other approved topcoats but with longer overcoating
periods include Amercoat 450S, Amercoat 4310, Amercoat 2136
and PSX 700#. No sealer is required for internal C1 service
conditions unless for cosmetic reasons. For internal C2 service
conditions Steelguard FM 549 must be adequately sealed with
Steelguard 2458 at 60 μm dry film thickness or other approved
topcoat. Please contact your PPG representative for specific
recommendations. It is important that the specified intumescent
thickness has been achieved before any topcoating.
(#Amercoat 71TC required as a tie coat)
Providing the steel is suitably primed and the dry film thickness of
the intumescent coating exceeds 400 μm, Steelguard FM 549 can
be left externally without a topcoat for up to 1 month and up to a
further 2 months in sheltered external conditions (i.e. steelwork in a
C2 environment). During this period, however, Steelguard FM 549
must be protected from pooling and running water, hot humid
environments or immersed conditions. Steelguard FM 549 must
have sufficient drying time before exposure in external conditions.
As a guide, at 15°C/59°F, for a dry film thickness of 700 μm, a
minimum drying period of 40 hours is recommended from time of
application of the final coat before exposure.
Refer to product drying tables for drying and overcoating
schedules.
Drying Characteristics
Drying times will vary considerably depending on ambient
-1
conditions, method of application, A/V m (Hp/A) of section being
coated and applied film thickness. As a guide, at 15°C/59°F a 400
μm dry film thickness coating will be touch dry in approximately 1
hour and hard dry after approximately 40 hours. For further details
on the drying times of Steelguard FM 549 refer to the drying tables
or contact your PPG representative.
Application Procedure:
1. Flush equipment with recommended cleaner Shipping Data
before use. Pack size ............................... 20 litres
2. Stir to an even consistency using a power mixer.
3. Thinning is normally not required. Shipping weight ..................... approx. 28 kg
4. For airless spray, apply a wet even coat in parallel Shelf life ................................. 1 year from shipment date when
passes. Overlap each pass 50% to avoid bare stored indoors in unopened, original containers at 5 to 40°C (41 to
areas, pinholes or holidays. 104°F).
5. Give special attention to welds, rough spots, sharp
edges and corners, rivets, bolts, etc.
6. Application at 590 μm wet film thickness will
normally provide 400 μm dry film.
7. Check thickness of dry coating with a non-
destructive dry film thickness gauge, such as
Mikrotest or Elcometer. If less than specified
thickness, apply additional material as needed.
8. Small damaged or bare areas and random
pinholes or holidays can be touched up by brush.
Repair larger areas by either by spray or brush
using Steelguard FM 549 or by trowel, knife,
spatula using Steelguard 2450 repair filler.
9. In confined areas ventilate with clean air during
application and drying until all solvents are
removed. Temperature and humidity of ventilating
air must be such that moisture condensation will
not form on surface.
10.Clean all equipment with recommended cleaner
immediately after use or at least at the end of each
working day or shift.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance when dry ............ matt
• Thin film solvent based intumescent Colour .................................... white, grey
• Tested to international fire test standards
Components ........................... 1
• Up to 2 hours fire protection of structural steel
• Off-site or on-site application Volume solids* ....................... 68 ± 3%
• Up to 1.5 mm dry film thickness application in VOC**
a single coat EC SED 1999/13/EC ........... 293g/kg (377 g/l)
• Rapid job completion UK PG6/23 (92) Appendix 3 325 g/l (2.7 lbs/gal)
• For use in C1, C2, C3 & C4 internal & external Curing mechanism ................. solvent release
environments - no sealer coat required for dry
internal C1 service conditions (ISO 12944) Loading requirements............. In order to establish the dry film
thickness required to give the
specified fire resistance reference
Typical Uses should be made to the products
-1
A/V m (Hp/A) or limiting
Intumescent fire protection for internal and external
temperature tables. Contact your
structural steel. Steelguard FM 550 is suitable for off site PPG representative for full details.
application by manual airless spray or automatic application
with pre-heat and accelerated drying facilities. Dry film thickness (μm) .......... 250 400 500 700 1000 1500
Wet film thickness (μm) ......... 370 590 740 1030 1470 2205
Approvals
Steelguard FM 550 has been tested to British Standard 476 2
Theoretical coverage (m /l) …. 2.72 1.70 1.36 0.97 0.68 0.45
Part 21 and UK assessed by Warrington Fire. Appraised by
the UK ASFP technical committee and approved for entry in (wet film thicknesses quoted are theoretical for one airless spray
the Yellow Book. Steelguard FM 550 has been assessed in coat)
accordance with the Dutch standard NEN 6072:2001 and Specific gravity ....................... 1.3 kg/l
also been assessed and certified to several national fire test
standards. Flashpoint
(closed cup) ......................... ºC ºF
Steelguard FM 550 .............. 25 77
Mixing Amercoat 65 ........................ 24 75
Stir thoroughly before use until the product is uniform
*Volume Solids is measured in accordance with ASTM D2697
throughout. This may cause an apparent thinning effect modified. Slight variations of up to ±3% may occur due to testing
which is normal for this product. A power mixer should be variances.
used.
** VOC figures are quoted according to the EC directive
1999/13/EC which are theoretically calculated figures and the UK
PG6/23 (92) Appendix 3 which are practically determined figures.
APPROVED PRODUCT
CF 456
Surface Preparation
Applied over a blasted and suitably primed steel substrate. The Application Data
surface must be dry and free of dust, salts, grease and other
contaminants immediately before coating. The primer used should Substrate ................................ primed abrasive blasted steel
be applied in accordance with the specific technical data sheet
instructions, and must be approved by PPG to ensure compatibility Application methods ............... airless spray, brush
with the Steelguard FM 550. The total dry film thickness of primer
Environmental Conditions
coats should generally not exceed 150 μm. For epoxy primers the
Relative humidity: ................ up to 85%
maximum allowable dry film thickness may be extended, consult
Surface temperature: ........... 5 - 50°C 41 - 122°F
your PPG representative prior to intumescent application.
Air temperature .................... 5 - 50°C 41 - 122°F
For off-site application Steelguard FM 550 may be applied directly
to the blast cleaned substrate provided the steelwork is to be used Surface temperature must be at least 3°C/5°F above the dew point
in dry internal C1 conditions and the dry film thickness exceeds 400 to prevent moisture condensation on the surface.
μm. The steel should be abrasive blast cleaned to ISO 8501-1 Sa
2½ with a blast profile of approximately 50-75 µm and should not Potlife .................................... not applicable
exceed 100 μm. Coating should occur before degradation of the
surface takes place. If oxidation occurs then the steel should be re- Thinner .................................. not normally necessary
prepared. The surface must be dry and free of dust, salts, grease Amercoat 65 can be used when needed (up to 5% by volume),
and other contaminants immediately before coating. However wet/ dry film measurement result will differ & lower max
film build as result will have to be considered
Drying Characteristics
Drying times will vary considerably depending on ambient
conditions, method of application, pre-heat and force drying
-1
conditions if used, A/V m (Hp/A) of section being coated and
applied film thickness. As a guide, at 15°C/59ºF a 400 μm dry film
thickness coating will be touch dry in approximately 1 hour and
hard dry after approximately 40 hours. For further details on the
drying times of Steelguard FM 550 refer to the product drying
tables or contact your PPG representative.
Overcoating
The standard recommended topcoat for Steelguard FM 550 is
Steelguard 2458 which allows for fast overcoating and job
completion. Other approved topcoats but with longer overcoating
periods include Amercoat 450S, Amercoat 4310, Amercoat 2136
and PSX 700#. No sealer is required for internal C1 service
conditions unless for cosmetic reasons. For internal C2 service
conditions Steelguard FM 550 must be adequately sealed with
Steelguard 2458 at 60 µm dry film thickness or other approved
topcoat. For C3 & C4 external service conditions Steelguard FM
550 must be adequately sealed with two coats Steelguard 2458 at
120 μm total dry film thickness or other approved topcoat. Please
contact your PPG representative for specific recommendations. It is
important that the specified intumescent thickness has been
achieved before any topcoating.
(#Amercoat 71TC required as a tie coat)
Application Procedure:
1. Flush equipment with recommended cleaner before use.
2. Stir to an even consistency with a power mixer.
3. Thinning is normally not required for airless spray.
4. For airless spray apply a wet even coat in parallel
passes. Overlap each pass 50% to avoid bare areas,
pinholes or holidays.
5. Give special attention to welds, rough spots, sharp
edges and corners, rivets, bolts, etc.
6. Application at 590 µm wet film thickness will normally
provide 400 µm dry film.
7. Check thickness of dry coating with a non- destructive
dry film thickness gauge, such as Mikrotest or
Elcometer. If less than specified thickness, apply
additional material as needed.
8. Small damaged or bare areas and random pinholes or
holidays can be touched up by brush. Repair larger
areas either by spray or brush with Steelguard FM 550
or by trowel, knife, spatula using Steelguard 2450 repair
filler.
9. For repair of damaged primerless systems where bare
steel is exposed, a suitable primer should be applied
prior to re-application of the intumescent coating.
10. In confined areas ventilate with clean air during
application and drying until all solvents are removed.
Temperature and humidity of ventilating air must be
such that moisture condensation will not form on
surface.
11. Clean all equipment with recommended cleaner
immediately after use or at least at the end of each
working day or shift.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance when dry ............ matt
• Solvent based thin film intumescent Colour .................................... white, grey
• 60 minutes fire protection of structural steel
Components ........................... 1
• On-site or off-site application
• Up to 1.5 mm dry film thickness application in Volume solids *....................... 75 ± 3%
a single coat
VOC**
• For use in C1, C2, C3 & C4 internal & external
environments - no sealer coat required for dry EC SED 1999/13/EC .............. 257 g/kg (346g/l)
internal C1 service conditions (ISO 12944) UK PG6/23 (92) Appendix 3... 330 g/l
APPROVED PRODUCT
CF 551
•
Surface Preparation
Applied over a blasted and suitably primed steel substrate. The Application Data
surface must be dry and free of dust, salts, grease and other
contaminants immediately before coating. The primer used should Substrate ................................ primed abrasive blasted steel
be applied in accordance with the specific technical data sheet
instructions, and must be approved by PPG to ensure compatibility Application methods ............... airless spray, brush
with the Steelguard 551. Suitable PPG primers include Amercoat
Environmental Conditions
71, 139, 182ZPHB, 3146P, 4116, Steelguard 3290, and Amercoat
Relative humidity: ................ up to 85%
68 series. The total dry film thickness of primer coats should
Surface temperature: ........... 5 – 50°C 41 – 122°F
generally not exceed 150 microns. For epoxy primers the maximum
Air temperature .................... 5 – 50°C 41 – 122°F
allowable dry film thickness may be extended, consult your PPG
representative prior to intumescent application. Surface temperature must be at least 3°C (5°F) above the dew
For off-site application Steelguard 551 may be applied directly to point to prevent moisture condensation on the surface.
the blast cleaned substrate provided the steelwork is to be used in
dry internal C1 conditions and the dry film thickness exceeds 400 Thinner .................................. not normally necessary
microns. The steel should be abrasive blast cleaned to ISO 8501-1 Amercoat 65 can be used when needed (up to 5% by volume),
Sa 2½ with a blast profile of approximately 50-75 microns and However wet/ dry film measurement result will differ & lower max
should not exceed 100 microns. Coating should occur before film build as result will have to be considered
degradation of the surface takes place. If oxidation occurs then the
steel should be re-prepared. The surface must be dry and free of Cleaner .................................. Amercoat 65
dust, salts, grease and other contaminants immediately before
coating.
Mixing
Stir thoroughly before use until the product is uniform throughout.
This may cause an apparent thinning effect which is normal for this
product. A power mixer should be used.
Application Methods
AIRLESS SPRAY - Use a pump capable of producing a minimum
pressure at the tip of 2800 psi (200 kg/cm²). A 30 mesh/500 micron
internal filter is recommended. Tip size 19-25 thou’ (0.48-0.63mm).
For on-site application Steelguard 551 can be applied in a single
coat up to 1.5mm dft. For off-site application it is recommended that
the product is applied in 700 microns dry film thickness coats
allowing a minimum of 8 hours drying at 15°C (59°F) between each
coat.
BRUSH – Apply evenly using a clean, well-loaded brush at up to
300 microns dry film thickness per coat. As a guide allow at least 2
hours drying at 20°C (68°F) between coats.
Drying Characteristics
Drying times will vary considerably depending on ambient
-1
conditions, A/V m (Hp/A) of section being coated and applied film
thickness. As a guide, at 15°C (59°F) a 700 microns dry film
thickness coating will be touch dry in 1 hour and hard dry after
approximately 40 hours. For further details on the drying times of
Steelguard 551 refer to the product drying tables or contact your
PPG representative.
Overcoating
The standard recommended topcoat for Steelguard 551 is
Steelguard 2458 which allows for fast overcoating and job
completion. Other approved topcoats but with longer overcoating
periods include Amercoat 450 series, Amercoat 4310, Amercoat
2136 and PSX 700#. No sealer is required for internal C1 service
conditions unless for cosmetic reasons. For internal C2 service
conditions Steelguard 551 must be adequately sealed with
Steelguard 2458 at 60 microns dry film thickness or other approved
topcoat. For C3 & C4 external service conditions Steelguard 551
must be adequately sealed with two coats Steelguard 2458 at 120
microns total dry film thickness or other approved topcoat. Please
contact your PPG representative for specific recommendations. It is
important that the specified intumescent thickness has been
achieved before any topcoating.
(# Amercoat 71TC required as a tie coat)
Application Procedure:
1. Flush equipment with recommended cleaner before use.
2. Stir to an even consistency with a power mixer.
3. Thinning is normally not required for airless spray.
4. For airless spray apply a wet even coat in parallel passes.
Overlap each pass 50% to avoid bare areas, pinholes or
holidays.
5. Give special attention to welds, rough spots, sharp edges
and corners, rivets, bolts, etc.
6. Application at 540 microns wet film thickness will normally
provide 400 microns dry film.
7. Check thickness of dry coating with a non- destructive dry
film thickness gauge, such as Mikrotest or Elcometer. If
less than specified thickness, apply additional material as
needed.
8. Limited areas of damage should be repaired using
Steelguard 2451 intumescent repair compound to the
specified dry film thickness. Repair larger areas either by
spray or brush using Steelguard 551.
9. For repair of damaged primerless systems where bare
steel is exposed, a suitable primer should be applied prior
to re-application of the intumescent coating.
10. In confined areas ventilate with clean air during
application and drying until all solvents are removed.
Temperature and humidity of ventilating air must be such
that moisture condensation will not form on surface.
11. Clean all equipment with recommended cleaner
immediately after use or at least at the end of each working
day or shift.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions
Physical Data
• Fast drying solvent based thin film intumescent Appearance when dry ............ matt
• Rapid drying providing reduced times to handling Colour .................................... white, grey
• Tested to international fire test standards
Components ........................... 1
• Up to 2 hours fire protection of structural steel
• Off-site or on-site application Volume solids *....................... 68 ± 3%
• Up to 1.0 mm dry film thickness application in a
VOC**
single coat EC SED 1999/13/EC ........... 294g/kg (377 g/l)
• For use in C1, C2, C3 & C4 internal & external UK PG6/23 (92) Appendix 3 325 g/l (2.7 lbs/gal)
environments - no sealer coat required for dry
internal C1 service conditions (ISO 12944) Curing mechanism ................. solvent release
Wet film thickness (µm) ......... 370 590 740 1030 1470
Approvals 2
Theoretical coverage (m /l) …. 2.72 1.70 1.36 0.97 0.68
Steelguard 560 has been tested to British Standard 476 Part 21
and UK assessed by Warrington Fire. Appraised by the UK (wet film thicknesses quoted are theoretical for one airless spray
ASFP technical committee and approved for entry in the Yellow coat)
Book. Steelguard 560 has been assessed in accordance with
the Dutch standard NEN 6072:2001 and also been assessed Specific gravity ....................... 1.3 kg/l
and certified to several national fire test standards.
Flashpoint
(closed cup) ......................... ºC ºF
Steelguard 560 ................... 4 39
Mixing Amercoat 12 ........................ 24 75
Stir thoroughly before use until the product is uniform
throughout. This may cause an apparent thinning effect which *Volume Solids is measured in accordance with ASTM D2697
is normal for this product. A power mixer should be used. modified. Slight variations of up to ±3% may occur due to testing
variances.
APPROVED PRODUCT
CF 457
Drying Characteristics
Drying times will vary considerably depending on ambient
conditions, A/V m-1 (Hp/A) of section being coated and applied
film thickness. As a guide, at 15°C/59°F a 700 µm dry film
thickness coating will be touch dry in 30 minutes and hard dry
after approximately 20 hours. For further details on the drying
times of Steelguard 560 refer to the product drying tables or
contact your PPG representative.
Overcoating
The standard recommended topcoat for Steelguard 560 is
Steelguard 2458 which allows for fast overcoating and job
completion. Other approved topcoats but with longer
overcoating periods include Amercoat 450S, Amercoat 4310,
Amercoat 2136 and PSX 700#. No sealer is required for
internal C1 service conditions unless for cosmetic reasons. For
internal C2 service conditions Steelguard 560 must be
adequately sealed with Steelguard 2458 at 60 µm dry film
thickness or other approved topcoat. For C3 & C4 external
service conditions Steelguard 560 must be adequately sealed
with two coats Steelguard 2458 at 120 µm total dry film
thickness or other approved topcoat. Please contact your PPG
representative for specific recommendations. It is important that
the specified intumescent thickness has been achieved before
any topcoating.
(# Amercoat 71TC required as a tie coat)
Application Procedure:
1. Flush equipment with recommended cleaner before use.
2. Stir to an even consistency with a power mixer.
3. Thinning is normally not required for airless spray.
4. For airless spray apply a wet even coat in parallel
passes. Overlap each pass 50% to avoid bare areas,
pinholes or holidays.
5. Give special attention to welds, rough spots, sharp
edges and corners, rivets, bolts, etc.
6. Application at 590 µm wet film thickness will normally
provide 400 µm dry film.
7. Check thickness of dry coating with a non- destructive
dry film thickness gauge, such as Mikrotest or
Elcometer. If less than specified thickness, apply
additional material as needed.
8. Small damaged or bare areas and random pinholes or
holidays can be touched up by brush. Repair larger
areas either by spray or brush with Steelguard 560 or by
trowel, knife, spatula using Steelguard 2450 repair filler.
9. For repair of damaged primerless systems where bare
steel is exposed, a suitable primer should be applied
prior to re-application of the intumescent coating.
10. In confined areas ventilate with clean air during
application and drying until all solvents are removed.
Temperature and humidity of ventilating air must be
such that moisture condensation will not form on
surface.
11. Clean all equipment with recommended cleaner
immediately after use or at least at the end of each
working day or shift.
Before using the product, read the label on the can and
consult the material safety data sheet.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance when dry ............ matt
• Fast drying solvent based thin film Colour .................................... white, grey
intumescent
Components ........................... 1
• Rapid drying providing reduced times to
handling Volume solids *....................... 75 ± 3%
• 60 minutes fire protection of structural steel
VOC**
• Off-site or on-site application
• Up to 1.0 mm dry film thickness application in EC SED 1999/13/EC .............. 255 g/kg (343 g/l)
a single coat UK PG6/23 (92) Appendix 3... 327 g/l
• For use in C1, C2, C3 & C4 internal & external
environments - no sealer coat required for dry Curing mechanism ................. solvent release
internal C1 service conditions (ISO 12944) Loading requirements............. In order to establish the dry film
thickness required to give the
specified fire resistance reference
Typical Uses should be made to the products
Intumescent fire protection for internal and external -1
A/V m (Hp/A) loading or limiting
structural steel. Suitable for I section columns, beams and temperature tables
hollow sections. Fast drying material intended for off-site
application using manual airless spray equipment. Allows Dry film thickness (microns) .. 200 400 500 700 1000
for rapid job completion, early resistance to mechanical Wet film thickness (microns) . 270 535 665 935 1335
damage and faster throughput of coated steelwork. Also
2
suitable for on-site application. Steelguard 561 is weather Theoretical coverage (m /l) …. 3.75 1.88 1.50 1.07 0.75
resistant for up to 12 months in normal conditions thereby
Specific gravity ....................... 1.35 kg/l
facilitating the transport, storage and erection phases on
construction projects. During these periods running/pooling Flashpoint (closed cup)
water, hot humid environments and immersed conditions Steelguard 561 .................... 4°C 39°F
must be avoided. Amercoat 65 ........................ 24°C 75°F
APPROVED PRODUCT
CF 550
•
Mixing
Stir thoroughly before use until the product is uniform throughout.
This may cause an apparent thinning effect which is normal for this
product. A power mixer should be used.
Application Methods
AIRLESS SPRAY - Use a pump capable of producing a minimum
pressure at the tip of 2800 psi (200 kg/cm²). A 30 mesh/500 micron
internal filter is recommended. Tip size 19-25 thou’ (0.48-0.63mm).
For off-site application it is recommended that the product is
applied in 700 microns dry film thickness coats allowing a minimum
of 6 hours drying at 15°C (59°F) between each coat.
BRUSH – Suitable only for small areas such as repairs. Apply
evenly using a clean, well-loaded brush at up to 300 microns dry
film thickness per coat. As a guide allow at least 2 hours drying at
20°C (68°F) between coats.
Drying Characteristics
Drying times will vary considerably depending on ambient
-1
conditions, A/V m (Hp/A) of section being coated and applied film
thickness. As a guide, at 15°C (59°F) a 700 microns dry film
thickness coating will be touch dry in 30 minutes and hard dry after
approximately 20 hours. For further details on the drying times of
Steelguard 561 refer to the product drying tables or contact your
PPG representative.
Overcoating
The standard recommended topcoat for Steelguard 561 is
Steelguard 2458 which allows for fast overcoating and job
completion. Other approved topcoats but with longer overcoating
periods include Amercoat 450 series, Amercoat 4310, Amercoat
2136 and PSX 700#. No sealer is required for internal C1 service
conditions unless for cosmetic reasons. For internal C2 service
conditions Steelguard 561 must be adequately sealed with
Steelguard 2458 at 60 microns dry film thickness or other approved
topcoat. For C3 & C4 external service conditions Steelguard 561
must be adequately sealed with two coats Steelguard 2458 at 120
microns total dry film thickness or other approved topcoat. Please
contact your PPG representative for specific recommendations. It is
important that the specified intumescent thickness has been
achieved before any topcoating.
(# Amercoat 71TC required as a tie coat)
Application Procedure:
1. Flush equipment with recommended cleaner before use.
2. Stir to an even consistency with a power mixer.
3. Thinning is normally not required for airless spray.
4. For airless spray apply a wet even coat in parallel passes.
Overlap each pass 50% to avoid bare areas, pinholes or
holidays.
5. Give special attention to welds, rough spots, sharp edges
and corners, rivets, bolts, etc.
6. Application at 540 microns wet film thickness will normally
provide 400 microns dry film.
7. Check thickness of dry coating with a non- destructive dry
film thickness gauge, such as Mikrotest or Elcometer. If
less than specified thickness, apply additional material as
needed.
8. Limited areas of damage should be repaired using
Steelguard 2451 intumescent repair compound to the
specified dry film thickness. Repair larger areas by airless
spray using Steelguard 561.
9. For repair of damaged primerless systems where bare
steel is exposed, a suitable primer should be applied prior
to re-application of the intumescent coating.
10. In confined areas ventilate with clean air during
application and drying until all solvents are removed.
Temperature and humidity of ventilating air must be such
that moisture condensation will not form on surface.
11. Clean all equipment with recommended cleaner
immediately after use or at least at the end of each working
day or shift.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Components ........................... 1
• Thin film water borne intumescent for on-site
application Volume solids* ....................... 70 ± 3%
• Environmentally friendly with low VOC and low
VOC**
odour EC SED 1999/13/EC .......... 20g/kg (28 g/l)
• Chlorine free UK PG6/23(92) Appendix 3 50g/l
• Tested to international fire test standards
Curing mechanism ................. water evaporation and polymer
• Up to 1 hour fire protection of structural steel coalescence
• For dry internal C1 conditions (ISO12944)
• Up to 700 µm dry film thickness per coat Loading requirements............. In order to establish the dry film
thickness required to give the
• Rapid job completion specified fire resistance reference
should be made to the products
-1
A/V m (Hp/A) or limiting
Typical Uses temperature tables. Contact your
Intumescent fire protection for internal structural steel in ISO PPG representative for full details.
12944 C1 conditions such as offices, hospitals, schools, shops.
Being waterborne and with very low odour it provides a friendly Dry film thickness (µm) .......... 250 400 500 700
and safer alternative to solvent based coatings for application
on site in enclosed environments. Wet film thickness (µm) ......... 360 570 715 1000
APPROVED PRODUCT
CF 458
Surface Preparation
Steelguard FM 580 must always be applied to a previously Application Data
blasted and primed steel substrate. The surface should be dry
Substrate ................................ primed abrasive blasted steel
and free of debris, dust, cement, salts, grease and other
contamination immediately before coating. The primer used Application methods ............... airless spray, brush, roller
should be applied in accordance with the specific product data
sheet instructions and must be approved by PPG to ensure Environmental Conditions
compatibility with the Steelguard FM 580. Do not apply
Steelguard FM580 directly on to metallic zinc coatings.The total Steelguard FM 580 must only be applied in dry, unexposed
dry film thickness of primer coats should not exceed 150 µm. conditions that will be free from high humidity and condensation.
Relative humidity: ................ up to 80%
Surface temperature: ........... 5 - 40°C 41- 104°F
Application Methods Surface temperature must be at least 3ºC/5°F above dew point to
Spray application will provide the smoothest finish. Brush and prevent moisture condensation on the surface. Optimum drying
roller application will result in a textured finish. conditions are at temperatures above 10°C/50°F with good air
AIRLESS SPRAY - Use a pump capable of producing a movement. In poorly ventilated areas it is recommended adequate
minimum pressure at the tip of 2800 psi (200 kg/cm²). Tip size ventilation is introduced to prevent retardation of drying. Steelguard
17-21 thou’ (0.43-0.53mm). A 30 mesh/500 µm internal filter is FM580 should not be applied if there is a risk of condensation and
recommended. Dry film thickness of initial coat should not the temperature falling during the initial drying stages.
exceed 700 µm. Take care not to over apply the coating
particularly in internal angles and corners. Subsequent coats Potlife .................................... not applicable
may be applied after 8 hours at 20°C/68°F, to a maximum dry
film thickness of 700 µm per coat. Thinner .................................. not normally necessary
Water can be used when needed (up to 5% by volume),
BRUSH/ROLLER- Apply evenly using a clean, well-loaded
However wet/ dry film measurement result will differ & lower max
brush or roller at up to 300 µm dry film thickness per coat. As a film build as result will have to be considered
guide allow at least 4 hours drying at 20°C/68°F between coats.
Cleaner .................................. fresh clean water
Drying Characteristics
Drying times will vary considerably depending on ambient
conditions, air movement, method of application, A/V m-1
(Hp/A) of section being coated and applied film thickness. As a
guide, at 20°C/68°F and 50% RH, a 400 micron dry film
thickness coating will be touch dry in approximately 2 hours
and hard dry after approximately 4 hours. For further details on
the drying times of Steelguard FM 580 refer to the drying tables
or contact your PPG representative.
Overcoating
Although there is no protective requirement for a topcoat in dry
internal C1 conditions, for decorative purposes Amercoat 220
series products are the recommended water borne topcoats.
Steelguard FM 580 should be left a minimum of 4 hours at
20°C 68°F) prior to overcoating with Amercoat 220. For details
of other approved topcoats such as Steelguard 2458 please
contact your PPG representative. It is important that the
specified intumescent thickness has been achieved before any
topcoating.
Application procedure
1. Clean the equipment with suitable solvent, then Shipping Data
thoroughly wash with clean water before use. Pack size ................................ 20 litres
2. Stir the product to an even consistency using a
power mixer. Thinning is not required. Shipping weight ..................... approx. 28 kg
3. For airless spray, apply a wet even coat in Shelf life ................................. 1 year from shipment date when
parallel passes. Overlap each pass by 50% to stored indoors in unopened,
avoid bare areas, pinholes or holidays. original containers at 5 to 30°C (41
to 86°F). Must be protected from
4. Give special attention to welds, rough spots, frost.
sharp edges and corners, rivets, bolts, etc.
5. Application at 570 µm wet film thickness will
normally provide 400 µm dry film.
6. Check thickness of dry coating with a non-
destructive dry film thickness gauge, such as
Mikrotest or Elcometer. If less than specified
thickness, apply additional material as needed.
7. Small damaged or bare areas and random
pinholes or holidays can be touched up by brush.
Repair larger areas either by spray, brush or roller
using Steelguard FM 580.
8. In confined areas ventilate with clean air during
application and drying. The humidity should be
maintained below 80% and the temperature such
that moisture condensation will not form on the
surface both during application and the initial
stages of drying.
9. Clean all equipment with fresh, clean water
immediately after use or at least at the end of
each working day or shift.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance when dry ............ Matt
• Thin film water borne intumescent for on-site Colour .................................... White
application
Components .......................... 1
• Environmentally friendly with low VOC and low
odour Volume solids*........................ 70 ± 3%
• Chlorine free
VOC**
• Tested to BS 476 Part 21 EC SED 1999/13/EC ........... 20g/kg (29 g/l)
• Up to 1 hour fire protection of structural steel UK PG6/23(92) Appendix 3 . 30g/l
• For dry internal C1 conditions (ISO12944)
Curing mechanism ................. water evaporation and polymer
• Up to 700 µm dry film thickness per coat coalescence
• Rapid job completion
Loading requirements............. In order to establish the dry film
thickness required to give the
Typical Uses specified fire resistance reference
should be made to the products
Intumescent fire protection for internal structural steel -1
A/V m (Hp/A) or limiting
in ISO 12944 C1 conditions such as offices, hospitals, temperature tables. Contact your
schools, shops. Being waterborne and with very low PPG representative for full details.
odour it provides a friendly and safer alternative to Dry film thickness (µm) .......... 250 400 500 700
solvent based coatings for application on site in
enclosed environments. Wet film thickness (µm) ......... 360 570 715 1000
APPROVED PRODUCT
CF 460
Surface preparation
Steelguard FM 585 must always be applied to a previously Application Data
blasted and primed steel substrate. The surface should be dry
Substrate ............................... primed abrasive blasted steel
and free of debris, dust, cement, salts, grease and other
contamination immediately before coating. The primer used Application methods .............. airless spray, brush, roller
should be applied in accordance with the specific product data
sheet instructions and must be approved by PPG to ensure Environmental Conditions
compatibility with the Steelguard FM 585. Do not apply
Steelguard FM585 directly on to metallic zinc coatings. The Steelguard FM585 must only be applied in dry, unexposed
total dry film thickness of primer coats should not exceed 150 conditions that will be free from high humidity and condensation.
µm.
relative humidity ................. up to 80%
Overcoating
Although there is no protective requirement for a topcoat in dry
internal C1 conditions, for decorative purposes Amercoat 220
series products are the recommended water borne topcoats.
Steelguard FM 585 should be left a minimum of 4 hours at
20°C/68°F prior to overcoating with Amercoat 220. For details
of other approved topcoats such as Steelguard 2458 please
contact your PPG representative. It is important that the
specified intumescent thickness has been achieved before any
topcoating
Application procedure
1. Clean the equipment with suitable solvent, then Shipping Data
thoroughly wash with clean water before use. Pack size ................................ 20 litres
2. Stir the product to an even consistency using a
power mixer. Thinning is not recommended. Shipping weight (typically)...... approx 29 kg
3. For airless spray, apply a wet even coat in Shelf life ................................. 1 year from shipment date when
parallel passes. Overlap each pass by 50% to stored indoors in unopened,
avoid bare areas, pinholes or holidays. original containers at 5 to 30°C (41
to 86°F). Must be protected from
4. Give special attention to welds, rough spots, frost.
sharp edges and corners, rivets, bolts, etc.
5. Application at 570 µm wet film thickness will
normally provide 400 µm dry film.
6. Check thickness of dry coating with a non-
destructive dry film thickness gauge, such as
Mikrotest or Elcometer. If less than specified
thickness, apply additional material as needed.
7. Small damaged or bare areas and random
pinholes or holidays can be touched up by brush.
Repair larger areas either by spray, brush or roller
using Steelguard FM 585.
8. In confined areas ventilate with clean air during
application and drying. The humidity should be
maintained below 80% and the temperature such
that moisture condensation will not form on the
surface both during application and the initial
stages of drying.
9. Clean all equipment with fresh, clean water
immediately after use or at least at the end of
each working day or shift.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance when dry ............ matt
• Solvent based intumescent repair compound Colour..................................... white
• Up to 2 mm dry film thickness per coat
Components ........................... 1
• Rapid job completion
Curing mechanism ................. solvent release
Flashpoint
(closed cup) ........................ ºC ºF
Steelguard 2450 .................. 26 79
Amercoat 65 ........................ 24 75
Cleaner................................... Amercoat 65
Application Procedure
Apply by trowel, knife or spatula. The coating should Shipping Data
be applied slightly proud of the surrounding area to Pack size ................................ 2.5 litres
allow for shrinkage on drying.
Shipping weight ...................... approx. 5kg
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance when dry ............ matt
• Solvent based intumescent repair compound Colour..................................... white
• Up to 2 mm dry film thickness per coat
Components ........................... 1
• Rapid job completion
Curing mechanism ................. solvent release
Flashpoint
(closed cup) ........................ ºC ºF
Steelguard 2451 .................. 26 79
Amercoat 65 ........................ 24 75
Surface Preparation
Cut out the Steelguard intumescent to one or two Application Data
centimetres from the damaged area in all directions Substrate ................................ primed steel (previously abrasive
back to a sound edge (large enough to allow for blasted)
suitable preparation). Ensure the exposed substrate
Application methods ............... trowel, knife or spatula
is clean dry and free of contamination. If a topcoat
has been applied this should be lightly sanded to Environmental conditions
remove from possible overlap areas. Where Relative humidity ................. up to 85%
Surface temperature ............ 5 - 40°C (41-104°F)
Steelguard intumescent has been applied directly to Air temperature .................... 5 - 40°C (41-104°F)
blast cleaned steel, any areas of breakdown should
be abrasive blast cleaned to ISO 8501-1, Sa 2½ or Surface temperature must be at least 3°C/5°F above dew point to
where this is not practical manually clean to ISO prevent moisture condensation on the surface.
8501-1 St2 minimum. A suitable PPG approved Drying times at 2mm wet film and 20°C/68°F
primer such as Amerlock 2C or 400C should then be touch dry .............................. 2 hours
applied before degradation of the surface takes place. handle dry ............................ 48 hours
fully cured ............................ 7 days
Where a primer has been originally used any areas of
breakdown should be repaired in accordance with the Drying time will vary considerably with the thickness applied and
original specification using a primer approved by ambient conditions.
PPG. If Steelguard 2451 is applied over other Overcoating times (minimum) at 20°C/68°F with itself and
manufacturers primers, compatibility must be checked Steelguard 2458
with your PPG representative prior to application. up to 0.5 mm dft................... 6 hours
0.5-1.0 mm dft...................... 12 hours
1.0-1.5 mm dft...................... 18 hours
Mixing 1.5-2.0 mm dft...................... 24 hours
Stir by hand to homogenise the product before use
Potlife ................................... not applicable
Cleaner................................... Amercoat 65
Application Procedure
Apply by trowel, knife or spatula. The coating should Shipping Data
be applied slightly proud of the surrounding area to Pack size ................................ 2.5 litres
allow for shrinkage on drying.
Shipping weight ...................... approx. 5kg
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions
Physical Data
• Fast drying solvent based thin film Appearance when dry ............ matt
intumescent Colour .................................... white
• Up to 2 hours fire protection of structural steel
Components ........................... 1
• Rapid drying providing reduced times to
handling Volume solids ........................ 67±3%
• EPA compliant (1998)
VOC*
• Tested to international fire test standards UK PG6/23(92) Appendix 3 . 394 g/l
including BS 476 Part 21
• Works or site application Curing mechanism ................. solvent release
• No sealer coat required for dry internal C1 Loading requirements............. In order to establish the dft required
service conditions (ISO 12944) to give the specified fire resistance,
reference should be made to the
products Hp/A (A/V) values or
Typical Uses limiting temperature tables. Contact
your PPG representative for full
Intumescent fire protection for internal and external details.
structural steel. Fast drying material intended for off-
site application using manual airless spray Dry film thickness (µm) .......... 250 400 500 700 1000
Wet film thickness (µm) ......... 373 597 746 1045 1493
equipment. Allows for rapid job completion, early 2
Theoretical coverage (m /l) …. 2.68 1.68 1.34 0.96 0.67
resistance to mechanical damage and faster (wet film thicknesses quoted are theoretical for one airless spray
throughput of coated steelwork. Also suitable for on- coat)
site application.
Specific gravity ....................... 1.27 kg/l
Flashpoint
Overcoating (closed cup) ......................... ºC ºF
The standard recommended topcoat for Steelguard Steelguard FM 2570 ......... 26 79
FM 2570 is Steelguard 2458. Amercoat 12 ..................... 24 75
For service in dry INTERNAL C1 conditions there is
no requirement for a topcoat. Where a coloured finish * VOC figures are quoted according to both the EC directive
is required Steelguard FM 2570 should be topcoated 1999/13/EC which are theoretically calculated figures and the UK
with Steelguard 2458, at a recommended dft of 50 PG6/23(92) Appendix 3 which are practically determined figures.
microns for C1 environments.
For service in EXTERNAL conditions or areas other
than dry internal C1 conditions, Steelguard FM 2570
must be sealed with an approved topcoat. Consult
your PPG representative for recommended topcoat
dft requirements.
Steelguard FM 2570 must be protected from pooling
water, hot humid environments or immersed
conditions at all times.
APPROVED PRODUCT
CF 542
Surface Preparation
Applied over a blasted and suitably primed steel Application Data
substrate. The surface must be dry and free of dust, Substrate ................................ primed steel
salts, grease and other contaminants immediately
before coating. The primer used should be applied in Application methods ............... airless spray, brush (small areas
only)
accordance with the specific technical data sheet
instructions, and must be approved by PPG to ensure Potlife (at 20°C/68ºF) ............ not applicable
compatibility with the Steelguard FM 2570. The total
Environmental Conditions
dry film thickness of primer coats should not exceed Relative humidity: ................ up to 80%
150 microns. Surface temperature: ........... minimum 5ºC/41ºF
The surface must be dry and free of dust, salts, ............................................. maximum 30ºC/86ºF
grease and other contaminants immediately before
The surface temperature must also be at least 3ºC/5ºF above dew
coating. point.
Stir thoroughly before use until the product is uniform Drying Characteristics
Drying times will vary considerably depending on ambient
throughout. A power mixer should be used. conditions, Hp/A (A/V) of section being coated and applied film
thickness. As a guide, at 20°C/68ºF the applied coating will be
touch dry in approximately 1 hour, recoatable in approximately 4
Application Methods hours and hard dry after 48 hours.
AIRLESS SPRAY - Use a pump capable of producing
a minimum pressure at the tip of 2800 psi (200 Thinner .................................. not normally necessary
Amercoat 65 can be used when needed (up to 5% by volume),
kg/cm²). Tip size 19-25 thou’ (0.48-0.63mm). However wet/ dry film measurement result will differ & lower max
BRUSH – Suitable only for small areas such as film build as result will have to be considered
repairs. Apply evenly using a clean, well-loaded brush
Cleaner .................................. Amercoat 12
at up to 300microns dft per coat. Allow at least 4
hours drying at 20ºC/68ºF between coats.
Application Procedure:
1. Flush equipment with recommended cleaner Shipping Data
before use. Pack size ................................ 20 litres
2. Stir to an even consistency with a power mixer.
3. Thinning is normally not required for airless spray. Shipping weight ..................... approx. 27 kg (20 l)
4. For airless spray apply a wet even coat in parallel Shelf life ................................. 12 months when stored indoors in
passes. Overlap each pass 50% to avoid bare unopened, original containers at 5
areas, pinholes or holidays. to 30°C (41 to 86ºF).
5. Give special attention to welds, rough spots, sharp
edges and corners, rivets, bolts, etc.
6. Application at 600 µm wet film thickness will
normally provide 400 µm dry film.
7. Check thickness of dry coating with a non-
destructive dry film thickness gauge, such as
Mikrotest or Elcometer. If less than specified
thickness, apply additional material as needed.
8. Small damaged or bare areas and random
pinholes or holidays can be touched up by brush.
Repair larger areas either by spray or brush with
Steelguard FM 2570.
9. In confined areas ventilate with clean air during
application and drying until all solvents are
removed. Temperature and humidity of ventilating
air must be such that moisture condensation will
not form on surface.
10.Clean all equipment with recommended cleaner
immediately after use or at least at the end of each
working day or shift.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Primers
Amercoat 68E
Amercoat 68G
Amercoat 139
Steelguard 3290
> START
We Know...
Fire Protection
Coatings
Amercoat
Amercoat 68E
High-Zinc Content Epoxy Primer
Product Data/
Application Instructions
• Contains minimum 85% zinc content by weight Physical Data
in the dry film
• Combines epoxy’s toughness with zinc’s Finish ..................................... matt
superior protection Colour .................................... reddish grey
• Outstanding resistance to severe weathering
• Superior performance in industrial and marine Components .......................... 2
environments Mixing ratio (by volume)
• Easily applied by airless or conventional spray resin .................................... 4 parts
cure...................................... 1 part
Application Procedure
Amercoat 68E is packaged in the proper mixing Shipping Data
proportions of resin and cure. Packaging
Resin: 8 l (2,1 gal) in 10 l can resin ............................... 8 l (2,1 gal) in 10 l can
Cure: 2 l (0,53 gal) in 2½ l can cure ................................ 2 l (0,53 gal) in 2½ l can
Product Data/
Application Instructions Physical Data
Finish ..................................... matt
• High metallic zinc content in the dry film Colour .................................... reddish grey
• Combines epoxy’s toughness with zinc’s
Components .......................... 2
superior protection
• Outstanding resistance to severe weathering Mixing ratio (by volume)
• Superior performance in industrial and marine resin .................................... 4 parts
cure...................................... 1 part
environments
• Easily applied by airless or conventional spray Curing mechanism ................ solvent release and reaction
between components
Amercoat 68G
Amercoat 68G
Application Procedure
Amercoat 68G is packaged in the proper mixing Shipping Data
proportions of resin and cure. Packaging
Resin: 8 l (2,1 gal) in 10 l can resin ............................... 8 l (2,1 gal) in 10 l can
Cure: 2 l (0,53 gal) in 2½ l can cure ................................ 2 l (0,53 gal) in 2½ l can
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Finish ..................................... matt
• Use as a weldable preconstruction primer or field or Colour .................................... oxide red and grey
shop applied primer
• Permits almost immediate handling, welding, cutting Components .......................... 2
and fabricating
Mixing ratio (by volume)
• Can be used with a wide range of topcoats resin .................................... 1 part
• Easily applied by automatic spray equipment cure ..................................... 1 part
• Simple 1:1 mixing ratio
Curing mechanism ................ solvent release and reaction
• Chromate and lead free between components
• EPA compliant in the UK as a blast primer
Dry film thickness .................. 15 - 25 µm
Application Data
Recommended Systems
TOPCOATING - Suitable topcoats are PPG epoxies, Substrate .......................... abrasive blasted steel
alkyds, coaltar epoxies, and polyurethanes. Prior to
topcoating, the primed surface must be clean and free of Application methods ......... airless or conventional spray
contamination, dust and foreign matter; special attention
must be given to damaged areas. Damaged areas can be Environmental Conditions
repaired with Amercoat 139 after cleaning by spot blasting (during application and drying)
or mechanical cleaning methods such as wire brushing, Air temperature: .............. 5 to 50°C 41 to 122°F
depending on the service conditions. Refer also to the Surface temperature: ...... 5 to 60°C 41 to 140°F
specific requirements and recommendations shown in the Effective cure down to 10°C/50ºF
product data of the intermediate and topcoats to be applied.
To prevent moisture condensation during application,
For specific recommendations contact your PPG
surface temperature must be at least 3°C/5ºF above dew
representative.
point. Never apply coatings under adverse environmental
conditions. Ensure good ventilation when applied in
Surface Preparation confined areas, to assist evaporation and elimination of
STEEL - Blast in accordance with Swedish Standard Sa 2½ solvents.
SIS 05.5900.1967 ISO 8501-1 or Steel Structures Painting Drying Times (in minutes at 25 µm dft, ºC/ºF)
Council SP-10. NOTE: Blast to achieve a 25 to 50 µm 20/68 30/86 40104
profile as determined with Testex Tape or similar dry to touch ..................... 2 1 30 seconds
instrument. Remove abrasive residues and dust from dry to handle ................... 10 6 2
surface. before full service ............ 60 30 15
IMPORTANT - Apply Amercoat 139 as soon as possible
after surface preparation to prevent any contamination. Do NOTE: Drying times are dependent on air and steel
not leave blasted steel uncoated overnight. In case of temperatures, applied film thickness, ventilation and other
contamination, remove contaminants. Spot blast steel if environmental conditions. Times are proportionally shorter
needed. at higher temperatures and longer at lower temperatures.
Prior to recoating, ensure the surface is clean. Maximum
recoating time depends on the coating system to be used.
Application Equipment Consult your PPG representative for specific
The following equipment is listed as a guide and suitable recommendations.
equipment from other manufacturers may be used.
Adjustments of pressure and change of tip size may be Recoat Times (in hours, ºC/ºF) 10/50 20/68 30/86
needed to obtain the proper spray characteristics. minimum ......................... 2 1 ½
AIRLESS SPRAY - Standard airless spray equipment, such Potlife (approx.)............... 24 16 10
as Graco Bulldog Hydra or larger, DeVilbiss, Nordson- (in hours)
Bede, Spee-Flo or others having a 28:1 or higher pump
ratio and a fluid nozzle with a 0.38 to 0.62 mm (0.015 to Potlife is dependent on temperature and quantities mixed.
0.025 inch) orifice.
CONVENTIONAL SPRAY - Industrial equipment such as Induction time ................... 10 minutes
DeVilbiss MBC or JGA gun with 78 or 765 air cap and "E" Thinner ............................. Amercoat 18
fluid tip and heavy mastic spring or Binks No. 18 or 62 with
a 66 x 63 PB nozzle set-up. Separate air and fluid pressure Cleaner ............................. Amercoat 12
regulators and a mechanical pot agitator and a moisture
and oil trap in the main air supply line is essential.
MIXER - Use power mixer powered by an air motor or an
explosion proof electric motor.
Product Data/
Application Instructions Physical Data
Finish ..................................... low sheen
• Rapid drying two pack epoxy zinc phosphate Colour .................................... red oxide, light grey, grey, buff and
primer off white.
• EPA compliant (1998) in accordance with Components .......................... 2
PG6/23
• High build, high solids and low VOC Mixing ratio (by volume)
resin .................................... 6.2 parts
• Corrosion inhibiting cure ..................................... 1 part
• Excellent adhesion to blast cleaned steel
• Excellent abrasion and impact resistance Curing mechanism ................ solvent release and reaction
between components. Effective
• No maximum overcoating restrictions cure down to 5°C/41ºF
Flash points
(Closed Cup)........................ ºC ºF
resin .................................... 24 75
cure ..................................... 24 75
Amercoat 18 ....................... 25 77
Amercoat 12 cleaner............ 24 75
Surface preparation
Surfaces must firstly be thoroughly cleaned of all Application Data
contaminants such as dust, dirt, oil, grease and salts. Substrate ............................... blasted steel
Then abrasive blast clean to ISO 8501-1, Sa21/2. The
blast profile achieved should be within the range 50 to Application methods .............. airless spray, brush or roller
100 microns. Priming should occur before Potlife (at 20°C/68ºF) ............ 2 hours
degradation of the surface takes place. If oxidation
occurs then the surface should be re-prepared. The Induction time (at 20°C/68ºF) not applicable
surface must be dry and free of dust, salts, grease Environmental conditions
and other contaminants immediately before coating.
Steelguard 3290 should only be applied within the limits of
temperature and humidity set out below.
Mixing Relative humidity: ................ Up to 90%
Surface temperature: ........... Minimum 2°C/36ºF
Stir the resin component thoroughly, then add the ............................................. Maximum 40°C/104ºF
cure and continue mixing until the product is uniform
throughout. A powerful mixer should be used. The surface temperature must also be at least 3°C/5ºF above the
dew point during application.
As with most coatings early contact with water can result in water
Application spotting damage. Care should be taken to protect the coating
AIRLESS SPRAY: Use standard airless spray during the early stages of cure to prevent water marking.
equipment capable of producing a minimum pressure
at the tip of 2800 psi (200 kg/cm²). Tip size range 15- Drying characteristics ºC/ºF
21 thou (0.38-0.53mm). Adjustments to pressure and Temperature 5/41 10/50 20/68
tip size/angle may be necessary to obtain spray
characteristics required for specific substrate Touch dry 4 hours 2 hours 1 hours
configurations.
BRUSH/ROLLER: Application by these methods Hard dry 8 hours 5 hours
1
2 /2 hours
should be limited to small areas only such as repairs
and when stripe coating. Apply evenly using a clean, Overcoating 1
8 hours 5 hours 2 /2 hours
(minimum)
well-loaded brush or roller. With this application more
Overcoating - - -
than one coat may be necessary to achieve the (maximum)
required dry film thickness
This product will cure down to 0°C/32ºF, however drying
times will be extended.
Application procedure
1. Clean the equipment with the recommended cleaning Shipping Data
solvent before use.
Packaging............................... 20 litres in two part units
2. Stir the resin component thoroughly, then add the cure resin .................................... 17.23 l in 20 l can
and continue mixing until the product is uniform cure ..................................... 2.77 l in 5 l can
throughout. A powerful mixer should be used. Thinning
is not required. Shipping weight (approx)
3. For airless spray, apply a wet even coat in parallel resin .................................... . 31 kg
passes. Overlap each pass by 50% to avoid bare areas, cure ..................................... 4 kg
pinholes or holidays. Shelf life ................................. 1 year from shipment date or as
4. Give special attention to welds, rough spots, sharp indicated on label when stored
edges and corners, rivets, bolts, etc. indoors in unopened, original
5. Application at 104µm wet film thickness will normally containers at 5 to 40°C (41 to
provide 75µm dry film. 104ºF).
6. Check thickness of dry coating with a non-destructive
dry film thickness gauge, such as Mikrotest or
Elcometer. If less than specified thickness, apply
additional material as needed.
7. Small damaged or bare areas and random pinholes or
holidays can be touched up by brush. Repair larger
areas either by spray, brush or roller using Steelguard
3290.
8. In confined areas ventilate with clean air during
application and drying. The humidity should be
maintained below 90% and the temperature such that
moisture condensation will not form on the surface.
9. Clean all equipment with fresh, clean solvent
immediately after use.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Topcoats
Amercoat 220G
Amercoat 220 LS
Amercoat 450E
Amercoat 2136
Steelguard 2458
Amercoat 4310
PSX 700
> START
We Know...
Fire Protection
Coatings
Amercoat
Amercoat 220 G
Water borne acrylic finish
Product Data/
Application Instructions Physical Data
Appearance when dry ........... glossy
• Single pack water borne acrylic finish Colour .................................... RAL and BS*
• EPA compliant (1998)
Components ........................... 1
• Low volatile organic compounds content
• Low odour Volume solids ........................ 40 ± 2%
• Non-flammable VOC**
• Good colour and gloss retention EC SED 1999/13/EC ........... 41 g/kg (50 g/l)
• Compatible with most aged coatings UK PG6/23(92) Appendix 3 . 140 g/l
• Quick and easy to apply by brush, roller and Curing mechanism ................. physical drying
spray
typical minimum maximum
Surface Preparation
Applied over surfaces primed typically with Amercoat Application Data
148 water borne primer. The priming system and Substrate ................................ primed substrates
preparation will depend on the type and condition of
the substrates. Consult your PPG representative for Application methods ............... airless spray, brush, roller
detailed specifications. Potlife (at 20°C/68ºF) ............ not applicable
All surfaces must be dry and free of dust, salts,
grease and other contaminants immediately before Environmental Conditions
coating. Amercoat 220 should only be applied within the limits of
temperature and humidity set out below.
Relative humidity: ................ up to 90%
Mixing Surface temperature: ........... minimum: 5ºC/41ºF
Stir thoroughly before use until the product is uniform maximum: 40°C/104ºF
throughout. The surface temperature must also be at least 3°C/5ºF above dew
point
Application procedure
1. Flush equipment with recommended cleaner Shipping Data
before use. Pack size ...................... 5 litres
2. Stir the contents of the can to an even
consistency. Shipping weight ............ approx. 7 kg
3. Thinning is normally not required for airless spray.
4. Stir during application to maintain uniformity of Shelf life ....................... 1 year from shipment date
material. When spraying, apply a wet even coat in or as indicated on label when
parallel passes. Overlap each pass 50% to avoid stored indoors in unopened,
bare areas, pinholes or holidays. original containers at 5 to
5. Double coat all rough spots, sharp edges and 40°C (41 to 104ºF)
corners, rivets, bolts, etc.
6. Application at 100 µm wet film thickness will
normally provide 40 µm dry film.
7. Check thickness of dry coating with a non-
destructive dry film thickness gauge, such as
Mikrotest or Elcometer. If less than specified
thickness, apply additional material as needed.
8. Small damaged or bare areas and random
pinholes or holidays can be touched up by brush.
Repair larger areas by spray.
9. In confined areas ventilate with clean air during
application and drying until all solvents are
removed. Temperature and humidity of ventilating
air must be such that moisture condensation will
not form on surface.
10.Clean all equipment with recommended cleaner
immediately after use or at least at the end of each
working day or shift
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Finish ..................................... Semi gloss
• Water borne one component topcoat Colour..................................... RAL and BS colours*
• Fast drying, durable finish coat
Components ........................... 1
• Suitable for temperatures down to 5ºC/41ºF
• Excellent resistance to weathering Mixing ratio (volume) .............. NA
• Good impact resistance and flexibility Curing mechanism ................. physical drying
• Scrub and stain resistant
• Brush, roller or spray application Volume solids ......................... 42% (calculated)
• Quick and easy clean up VOC**
• Low odour, low VOC emission EC SED 1999/13/EC ........... 16 g/kg (21 g/l)
UK PG6/23(92) Appendix 3 . 20 g/l (0.2 lbs/gal)
Outstanding Characteristics
Amercoat 220 LS provides a beautiful, flexible, cleanable
Application Data
low sheen finish that resists cracking, peeling and impact
damage. It retains colour and sheen far better than Substrates ............................. Prepared and primer steel coated
traditional alkyd or chlorinated rubber topcoats. with PPG intumescent or other
Amercoat 220 LS can be used to replace solvent borne suitable primer, prepared concrete,
alkyd or chlorinated rubber topcoats to significantly reduce wood, dry wall
solvent emissions.
Surface preparation................ Refer to Typical Systems for
specific primer or intermediate
coatings recommended.
Surface Preparation
Steelguard FM intumescents - Ensure surfaces are clean, Application method................. Airless or conventional spray,
free from dust, oil, grease, dirt or other contaminants. brush or roller.
STEEL - Prepare surface in accordance with application
instructions for the specific primer being used. Be sure Environmental conditions
primer is clean and dry when Amercoat 220LS is applied. Air temperature .................... 4 - 43 °C 40 - 110 °F
Surface temperature............ 4 - 43 °C 40 - 110 °F
OTHER COATED SURFACES - Ensure surfaces are clean, Material temperature ........... 10 to 30°C 50 - 86 °F
free from dust, oil, grease, dirt or other contaminants.
Depending on condition and cleanliness of surface, Relative Humidity (RH)
cleaning by high pressure water washing (70 atm/1000 psi at 5 to 10°C........................ max. 60%
or higher) may be required. If substrate coating is not an at 10 to 40°C........................ max. 85%
approved PPG primer, a test patch should be applied to at > 40°C.............................. max. 95%
confirm adhesion. Surface temperature must be at least 3°C / 5°F above the dew
point to prevent moisture condensation on the surface.
Application Equipment
The following equipment is listed as a guide and suitable
equipment from other manufacturers may be used. Drying Times as outlined under environmental conditions
Adjustments of pressure and change of tip size may be
Drying times (°C/°F) 49/120 32/90 21/70 10/50
needed to obtain the proper spray characteristics. Dry to touch ......................... NR 15 min 15 min 45 min
Dry through .......................... NR 15 min 30 min 2 hrs
AIRLESS SPRAY - Standard airless spray equipment, such
as Graco, DeVilbiss, Nordson-Bede, Speed-Flo, or others
and a fluid tip with a 0.28 to 0.43 mm (0.011 to 0.017 inch) Recoat times (°C/°F) 49/120 32/90 21/70 10/50
orifice. Minimum times (hrs) ............ NR 0.5 2 6
CONVENTIONAL SPRAY - Industrial equipment such as Thinner ................................... Water
DeVilbiss MBC or JGA gun with 75 or 765 air cap and "E"
fluid tip and heavy mastic spring or Binks No. 18 or 62 with Equipment cleaner ................. Water or water with detergent
a 66 x 63 PB nozzle setup. Separate air and fluid pressure
regulators and a mechanical pot agitator are recommended.
A moisture and oil trap in the main air supply line is
essential.
Repair
Spot blast or power tool clean bare substrate to the
requirements shown under surface preparation and
prime with original coating material. Feather edges of
intact coating. Remove dust, dirt and contamination
before recoating.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
• High gloss high UV exposure resistant topcoat Colour........................................ RAL & BS-colours*
available as gloss and semi-gloss finish
Components .............................. 2
(Amercoat 450E SG)
• Outstanding weather resistance with excellent Mixing ratio (volume) ................. 4 parts resin to 1 part cure
colour and gloss retention Density
• Resistant to a broad range of corrosive and Amercoat 450E gloss.............. 1.37 (white, mixed product)
marine atmospheres Amercoat 450E semi gloss ..... 1.44 (white, mixed product)
• Resists soil pick up and easily cleaned Curing mechanism..................... solvent evaporation and reaction
• Hard, tough, flexible, and abrasion resistant between components
• Cures through a wide temperature range Volume solids ............................ 60% ± -3% (ISO 3233)**
• Recoatable finish
VOC***
• BBA HAPAS and Network Rail approved EC SED 1999/13/EC .............. 303 g/kg (413 g/l)
UK PG6/23(92) Appendix 3 .... 350 g/l (2.9 lbs/gal)
Application Procedure
Amercoat 450E is packaged in the proper mixing Shipping Data
proportions of resin and cure which must be mixed Packaging
together before use. Resin............................... 16 L in 20 L can
Cure ................................ 4 L in 5 L can
1. Flush equipment with recommended cleaner before use.
2. Stir both resin and cure to a uniform consistency with a Shipping weight kg lb
power mixer. 20 litre units
3. Add cure to resin, and continue stirring for 5 minutes. Resin............................ 25 55
NOTE: since the potlife is limited and shortened by high Cure ............................. 5 11
temperatures, do not mix more material than will be
used within the potlife at the specified temperature. 5 litre units
4. For spray application, thin only as needed for workability Resin............................ 6 13.2
with no more than 10 vol % of recommended thinner. Cure ............................. 1.3 2.8
For application at temperatures below 10°C (50°F),
more thinner may be required to ensure proper Shelf life............................. 1 year from shipment date
atomizing. when stored indoors in
NOTE: For brushing and rolling, normally no thinning is unopened, original containers
required. at 5 to 40°C
5. Apply a wet coat in even, parallel passes. Overlap each (41 to 104°F)
pass 50% to avoid bare areas, pinholes or holidays.
6. Double coat all welds, rough spots, sharp edges and
corners, rivets, bolts, etc.
7. Application at 83 µm (3.3 mil) wet film thickness will
normally provide 50 µm (2 mils) dry film.
8. Check thickness of dry coating with a non-destructive
dry film thickness gauge, such as Mikrotest or
Elcometer. If less than specified thickness, apply
additional material as needed.
9. Small damaged or bare areas and random pinholes or
holidays can be touched up by brush. Repair larger
areas by spray.
10. In confined areas ventilate with clean air during
application and drying until all solvents are removed.
Temperature and humidity of ventilating air must be
such that moisture condensation will not form on
surface.
11. Clean all equipment with recommended cleaner
immediately after use or at least at the end of each
working day or shift. When left in spray equipment,
Amercoat 450E will cure and cause clogging.
Repair
For repair, or application of additional thickness,
Amercoat 450E may be over coated with itself
unlimited. Ensure surface is clean prior to application.
Product Data/
Application Instructions
• One-coat, high-build functional finish Physical Data
• Direct adhesion to galvanized steel
• Extensive track record Appearance when dry ............ low sheen, metallic sparkle or
lustre
• Single pack material
• Compatible with most aged coatings Colour .................................... black, medium grey, silver grey,
• Free from over coating stress light silver
Components ........................... 1
Typical Uses Curing mechanism ................. Solvent release
Amercoat 2136 is a high build, micaceous iron oxide
pigmented coating designed to protect both steel and Volume solids ........................ 53±2%
galvanized steel structures including tank roofs/shell VOC*
externals, fences, galvanized ducts/cladding, street EC SED 1999/13/EC ........... 304 g/kg (484 g/l)
furniture and lighting columns. UK PG6/23(92) Appendix 3 . 490 g/l
Surface Preparation
All surfaces must be dry and free of dust, salts, Application Data
grease and other contaminants immediately before Substrate ................................ Primed or galvanized steel
coating. Reference should be made to the relevant
product data sheets of recommended primers and Application methods ............... airless spray, brush, roller
cleaning materials as detailed below. Environmental Conditions ......
relative humidity:.................. up to 90%
NEWLY GALVANIZED STEEL - Thoroughly clean surface temperature:............ 5-30°C (41-86°F)
with Amercoat 57 or similar degreasing material and Surface temperature must be at least 3°C (5°F) above dew point to
rinse with clean fresh water. Ensure surface is free of prevent moisture condensation on the surface.
pre-treatments and white zinc salts before coating by
Potlife (at 20°C/68°F) ............ not applicable
scrubbing/scouring the effected areas and rinsing with
clean fresh water. Allow to dry completely before Drying times (°C/°F) ............... 10/50 20/68 30/86
coating. Touch dry (hours) ................ 2 1 ½
WEATHERED GALVANIZED STEEL - Thoroughly Hard dry (hours)................... 8 4 2
Full cure (days) .................... 10 7 4
clean with Amercoat 57 or similar degreasing material
and rinse with clean fresh water. Ensure surface is Recoat or topcoat times (°C/°F) 10/50 20/68 30/86
free of white zinc salts before coating by minimum/hours .................... 24 16 8
maximum ............................. - - -
scrubbing/scouring the effected areas and rinsing with
clean fresh water. Allow to dry completely before Drying and curing times are dependent on air and steel
coating. Rusted steel should be patch primed using temperature, applied film thickness, ventilation and other
Amercoat 385P, Amercoat 182ZP HB, Amercoat environmental conditions. Times are proportionally shorter at higher
temperatures and longer at lower temperatures.
4180 or other suitable PPG anti corrosive primer.
PREVIOUSLY COATED STEEL/GALVANIZED Thinner .................................. Amercoat 65
STEEL - Feather edges of sound paint back using
Cleaner .................................. Amercoat 65
abrasive means. Roughen surface mechanically to
provided a "key" for the new coating. Rusted/exposed
steel should be patch primed using Amercoat 385P,
Amercoat 182ZP HB, Amercoat 4180 or other
suitable PPG anti corrosive primer. A test area is
advised to ensure no reaction with the existing
coating.
STEEL NON GALVANIZED- Applied over Amercoat
385P, Amercoat 182ZP HB, Amercoat 4180 or other
suitable PPG anti corrosive primer.
Application Equipment
The following equipment is listed as a guide and suitable
equipment from other manufacturers may be used.
Adjustments of pressure and change of tip size may be
needed to obtain the proper spray characteristics.
BRUSH/ROLLER - Apply evenly using a clean, well loaded
brush or roller. Do not attempt to “brush out” or “lay off” the
wet coating.
AIRLESS SPRAY - May be thinned if necessary with up to
10% by volume of the recommended thinner. Tip size 15 -
18 thou’(0.38 - 0.46mm).
Pressure at tip: 2800 psi (200 kg/cm2).
Application Procedure
1. Flush equipment with recommended cleaner Shipping Data
before use. Pack size....................... 5 litres (1,32 gal)
2. Stir the contents of the can to an even consistency
with a power mixer. Shipping weight ............ approx 8.5 kg
3. Thin if necessary with up to 10% by volume of the
recommended thinner. Shelf life ....................... 1 year from shipment when
4. Stir during application to maintain uniformity of stored indoors in unopened,
material. Apply a wet even coat in parallel passes. original containers at 5°C to
Overlap each pass 50% to avoid bare areas, 40°C (41-104°F).
pinholes or holidays.
5. Double coat all welds, rough spots, sharp edges
and corners, rivets, bolts, etc.
6. Application at 142 µm (5,7 mils) wet film thickness
will normally provide 75 µm (3 mils) dry film.
7. Check thickness of dry coating with a non-
destructive dry film thickness gauge, such as
Mikrotest or Elcometer. If less than specified
thickness, apply additional material as needed.
8. Small damaged or bare areas and random
pinholes or holidays can be touched up by brush.
Repair larger areas either by spray or brush.
9. In confined areas ventilate with clean air during
application and drying until all solvents are
removed. Temperature and humidity of ventilating
air must be such that moisture condensation will
not form on surface.
10.Clean all equipment with water immediately after
use or at least at the end of each working day or
shift
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions
• EPA compliant (1998) as a finish for Steelguard Physical Data
intumescent coatings Appearance when dry ........... semi gloss
• High build
Colour .................................... RAL and BS colours*
• Suitable for external exposure
• Single pack material Components ........................... 1
• Good colour retention Curing mechanism ................. Solvent release
(Wet film thicknesses quoted are theoretical for one airless spray
coat)
Flashpoint
(closed cup) ......................... ºC ºF
Steelguard 2458 .................. 24 75
Amercoat 65 ........................ 24 75
Surface Preparation
The surface must be dry and free of dust, salts, Application Data
grease and other contaminants immediately before Substrate ............................. Steelguard FM 549/ Steelguard
coating. FM 550/ Steelguard FM560
coated steel
Application Procedure:
1. Flush equipment with recommended cleaner Shipping Data
before use. Pack size ...................... 20 litres
2. Stir to an even consistency with a power mixer.
3. Thinning is normally not required for airless spray Shipping weight ........... approx. 28 kg
4. Stir during application to maintain uniformity of
material Apply a wet even coat in parallel passes. Shelf life ....................... 1 year when stored indoors
Overlap each pass 50% to avoid bare areas, in unopened, original
pinholes or holidays. containers at 5 to 40°C (41-
5. Double coat all rough spots, sharp edges and 104°F).
corners, rivets, bolts, etc.
6. Application at 167 µm wet film thickness will
normally provide 75 µm dry film.
7. Check thickness of dry coating with a non-
destructive dry film thickness gauge, such as
Mikrotest or Elcometer. If less than specified
thickness, apply additional material as needed.
8. Small damaged or bare areas and random
pinholes or holidays can be touched up by brush.
Repair larger areas by spray.
9. In confined areas ventilate with clean air during
application and drying until all solvents are
removed. Temperature and humidity of ventilating
air must be such that moisture condensation will
not form on surface.
10. Clean all equipment with recommended cleaner
immediately after use or at least at the end of each
working day or shift.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Mixing
Stir thoroughly before use until the product is uniform
throughout.
Application Methods
AIRLESS SPRAY: Use standard airless spray Application Data
equipment capable of producing a minimum pressure Substrate ................................ Primed substrates
at the tip of 2800 psi (200 kg/cm²). Tip size range 13-
17 thou (0.33-0.43mm). Adjustments to pressure and Application methods ............... airless or conventional spray, brush
or roller
tip size/angle may be necessary to obtain spray
characteristics required for specific substrate Potlife (at 20°C/68ºF) ............ N/A
configurations.
Environmental Conditions
CONVENTIONAL SPRAY: Use standard industrial Amercoat 4310 should only be applied within the limits of
equipment. Thinning with the recommended thinner temperature and humidity set out below.
may be necessary to facilitate application. Relative humidity: ................ up to 90%
BRUSH/ROLLER: Apply evenly using a clean, well- Surface temperature: ........... minimum: 5°C/41ºF
............................................. maximum: 40°C/104ºF
loaded brush or roller. With this application more than
one coat may be necessary to achieve the required dry The surface temperature must also be at least 3°C/5ºF above dew
film thickness. point.
NOTE: drying and curing times are dependent on air and steel
temperature, applied film thickness, ventilation and other
environmental conditions. Times are shorter at higher temperatures
and longer at lower temperatures
Application procedure
1. Flush equipment with recommended cleaner Shipping Data
before use. Pack size ............................... 5 litres
2. Stir the contents of the can to an even
consistency. Shipping weight ...................... approx. 6 kg
3. Thinning is normally not required for airless spray. Shelf life ................................. 1 year from shipment date or as
4. Stir during application to maintain uniformity of indicated on label when stored
material. Apply a wet even coat in parallel passes. indoors in unopened, original
containers at 5 to 40°C (41 to
Overlap each pass 50% to avoid bare areas, 104ºF).
pinholes or holidays.
5. Double coat all rough spots, sharp edges and
corners, rivets, bolts, etc.
6. Application at 85 µm wet film thickness will
normally provide 40 µm dry film.
7. Check thickness of dry coating with a non-
destructive dry film thickness gauge, such as
Mikrotest or Elcometer. If less than specified
thickness, apply additional material as needed.
8. Small damaged or bare areas and random
pinholes or holidays can be touched up by brush.
Repair larger areas by spray.
9. In confined areas ventilate with clean air during
application and drying until all solvents are
removed. Temperature and humidity of ventilating
air must be such that moisture condensation will
not form on surface.
10.Clean all equipment with recommended cleaner
immediately after use or at least at the end of each
working day or shift
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Application Instructions
Physical Data
Finish ..................................... gloss
• Unique, high-gloss, engineered siloxane
• Can be applied directly over inorganic zinc Colour .................................... RAL and BS colours*
• Gloss and appearance retention exceeding the Components .......................... 2
best polyurethane
Mixing ratio (by volume)
• Significantly lower application costs
PSX 700 resin ..................... 4 parts
• Excellent corrosion resistance PSX 700 FD cure ................ 1 part
• High solids, VOC compliant
Curing mechanism ................ chemical reaction
• Applied by brush, roller or spray, without
thinning Volume solids ........................ 90% (ISO 3233)**
VOC***
Characteristics EC SED 1999/13/EC ........... 132 g/kg (180 g/l)
EPA Method 24.................... 84 g/l (0.7 lbs/gal)
PSX Advantage: PSX 700 is a patented engineered UK PG6/23(92) Appendix 3 . 120 g/l (1.0 lbs/gal)
siloxane coating and embodies the properties of both
a high performance epoxy and a polyurethane in one Dry film thickness*** .............. 75 - 175 µm per coat
coat. This general purpose coating offers Number of coats .................... 1 or 2 ****
“breakthrough” weather resistance and corrosion
control. Calculated coverage .............. 7.2 m²/l at 125 µm
• Structural steel; *colours with reduced hiding power (e.g. bright oranges and
• Industrial plants: chemical, petrochemical; yellows) must be applied over a white substrate. Appearance will
vary depending on substrate and application method. Use two
• Power plants: conventional, nuclear; coats of PSX 700 over bare concrete.
• Offshore industry: superstructures;
• Wastewater treatment plants; **Volume solids is measured in accordance with ISO 3233. Slight
variations ±3% may occur due to colour and testing variances.
• Pulp and paper industry;
• Marine: decks, topsides and boottops on ships and *** The mixed and applied coating cure reaction will produce VOC
barges; of mixed alcohols. VOC figures are quoted according to the EC
directive 1999/13/EC which are theoretically calculated figures. The
• Concrete walls and floors; USA Environmental Protection Agency guidelines method 24 and
• Transportation: rail car exteriors, vehicle the UK PG6/23(92) Appendix 3 are practically determined figures.
equipment, buses, trucks;
**** When applying more than 1 coat it is recommended that the
total dry film thickness does not exceed 250 microns
Surface Preparation * Brush or roller application may require additional coats. In order to
STEEL/CONCRETE - Prepare surface in accordance with achieve the specified dft.
application instructions for the specific primer used. Be sure primer
is clean and dry when PSX 700 is applied.
EXISTING COATINGS - PSX 700 may be used over many types of
properly cleaned, tightly adhering coatings. Consult your PPG
representative for specific recommendations.
Repair
Prepare damaged areas to original surface preparation
specifications, feathering edges of intact coating. Thoroughly
remove dust or abrasive residue before touch up
Heat Curing
Allow PSX 700 to dry to touch before exposing to curing
temperatures above 60°C140ºF.
Application Procedure
1. Flush equipment with thinner or Amercoat 12 before use.
2. Mix to a uniform consistency.
3. Add PSX 700 FD cure to PSX 700 resin. Mix thoroughly until
uniformly blended.
4. If needed for workability, thin with recommended thinner up to
10% by volume.
5. Apply a wet coat in even, parallel passes, overlap each pass 50
percent to avoid holidays, bare areas and pinholes. If required,
follow with a cross spray at right angles to first pass.
6. Brush and/or roll applications may require more than one coats
to achieve a 175 µm dft. There will be some surface texture,
which is typical for brush and roll applications.
7. When applying PSX 700 directly over Dimetcote, a mist
coat/full coat technique may be required to minimize bubbling.
Thin PSX 700 with recommended thinner up to 10% by volume
to assist in film thickness control and to minimize bubbling. This
will depend on the age of the coating, surface roughness and
conditions during curing.
8. Clean all equipment with thinner or Amercoat 12 cleaner
immediately after use
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Language Selection
Dutch
We Know...
Fire Protection
Coatings
PROFESSIONALS IN PROTECTION
> START
We Know...
Fire Protection
Coatings
PROFESSIONALS IN PROTECTION
Cementitious Coatings
Steelguard CM 4701
Steelguard CM 4702
Steelguard CM 4703
Steelguard CM 4704
Steelguard CM 4705
Steelguard CM 4706
> START
We Know...
Fire Protection
Coatings
Amercoat
Steelguard CM 4701
Spray Applied Fire Resistant Tunnel Coating
Product Data/
Application Instructions Physical Data
Appearance ............................ sprayed textured finish, usually
trowelled to close the surface
• Passive fire protection for use in tunnels
• Spray applied Colour .................................... off white
• Durable, impact resistant Components ........................... 1 (excluding water/additives)
• Modified vermiculite cement
3
• Tested to meet recognized international tunnel Dry density of the powder....... 465 kg/m
standards 3
Nominal dry density applied ... 725-775 kg/m
• Most fire ratings achieved in one single application
• Top coat systems to meet required colour and VOC ....................................... 0 g/l
reflectance levels
Curing mechanism ................. Hydrolisation
• Easy clean top coats
• Up to 4 hours insulation Thickness requirements ......... Contact PPG for details
Approvals
Steelguard CM 4701 is tested to resist fire conditions
in tunnels meeting recognized international tunnel
standards including the RATB in Germany,
Eurocode’s 1, 2 & 3 (EN 1991-1-2; EN 1992-1-2 & EN
1993-1-2) and the Dutch Rijkswaterstaat in
cooperation with the TNO Institute using the ‘RWS
97-CVB-R0710 Hydrocarbon time/temperature curve.
Project specific tunnel fire test may be required.
For suitable tunnel system specification contact PPG
for details.
Application Equipment
Use a mechanical piston or rotor stator type pump equipped
with a high-pressure plaster type hose avoiding brass or
aluminium type couplings. The flexible hose length should not
exceed 100 meters, with following typical length.
I.D. 75 mm (3”) maximum 100 meters
I.D. 50 mm (2”) maximum 50 meters
I.D. 35 mm (1 ½ ”) maximum 15 meters
I.D. 30 mm (1 ¼ ”) maximum 8 meters
For longer lengths use metal pipe with a I.D. of 65 -75 mm
Use as spray nozzle assembly a minimally 25-32 mm nozzle
with a 10 to 13 mm nozzle orifice and a rubber blow-off cap.
Atomising air should be 2-4 bar (28-57 psi) at the nozzle.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance ............................ sprayed textured finish, usually
trowelled to close the surface
• Passive fire protection for use in refineries and tank
storage facilities, in industrial and chemical plants and Colour .................................... grey
on offshore platforms.
• Meets international hydrocarbon fire standards Components ........................... 1 (excluding water/additives)
• Spray applied Dry density of the powder....... 465 kg/m
3
levelling by trowel this can be achieved by spray application At the end of the spray line 1050 – 1200 kg/m
3
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance ............................ sprayed textured finish, usually
trowelled to close the surface
• Passive fire protection for steel framed structures
• Spray applied Colour .................................... light grey
• Durable, impact resistant Components ........................... 1
• Modified vermiculite cement
3
• Up to 4 hours fire protection of structural steel Nominal dry density ............... 725-775 kg/m
• Most fire ratings achieved in one single application VOC ....................................... 0 g/l
• Excellent weathering resistance meeting upto ISO
12944 C5M requirements. Curing mechanism ................. Hydrolisation
levelling by trowel this can be achieved by spray application At the end of the spray line 1050 – 1200 kg/m
3
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance ............................ sprayed textured finish, usually
trowelled to close the surface
• Passive fire protection for steel framed
structures Colour .................................... grey
• Spray applied Components ........................... 1
• Robust coating for internal C1/C2
3
environments (ISO 12944) Nominal dry density ............... 350-400 kg/m
• Modified vermiculite cement VOC ....................................... 0 g/l
• Up to 4 hours fire protection of structural steel
• Most fire ratings achieved in one single Curing mechanism ................. Hydrolisation
application Loading requirements: In order to establish the thickness required
to give the specified fire resistance, reference should be made to
the products Hp/A (A/V) values or limiting temperature tables.
Typical Uses Contact your PPG representative for full details.
Steelguard CM 4704 is a tough hard and highly stable
passive fire protection for use on internal structural steel. Nominal usage at 25 mm thickness
The spray-applied coating shows excellent mechanical Per 25 kg sack........................ 2.65 m
2
resistance. It does not rely on any form of expansion, Per tonne................................ 106 m
2
levelling by trowel this can be achieved by spray application At the end of the spray line 900 – 1050 kg/m
3
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance ............................ clear when dry
• Additive for modified Steelguard CM Colour .................................... milky white liquid
vermiculate cement coatings
Components ........................... 1
• Adhesion promoter in bonding coat
• Improves substrate adhesion Specific gravity ....................... 1.08 kg/l
• Improves cohesive strength
pH........................................... 4.5 – 5.5
• Improves early water resistance
Volume solids ......................... 50% ± 2%
Application Procedure
Steelguard CM 4705 must be thoroughly stirred Application Data
before used. Thinner .................................. Do not thin
Shipping Data
Pack size ................................ 25 litre pails
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions
• Sealer coat for alkyd, unknown primers Physical Data
• Prevents primer saponification
• Adhesion promoter for primed steel Appearance ............................ matt
Theoretical coverage at 50
microns dry film thickness ..... 5.4 m²/litre
Surface Preparation
Ensure that the existing coating is clean, dry, sound Application Data
and free from any dirt, dust or contamination Substrate ................................ coated steel
immediately before coating. Any loose adherent
coating should be removed back to firm edge and Application method................. brush, roller, airless and
conventional spray
suitably patch repaired.
Environmental Conditions
Ambient temperature .......... 5 to 25°C 41 to 77ºF
Mixing Surface temperature: ........... 4°C/39ºF minimum
Steelguard CM 4706 must be thoroughly stirred
before use. Surface temperature must be at least 2°C/4°F above the dew point
to prevent moisture condensation on the surface.
Shipping Data
Pack size ................................ 25 litre pails
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Brandwerende Coatings
> START
We Know...
Fire Protection
Coatings
Amercoat
®
Pitt-Char XP
Brandwerende epoxycoating
Productinformatie/
Applicatie-instructies Technische gegevens
Uiterlijk.................................... glanzend
• Superieure bescherming tegen brand en Kleur ....................................... grijs
corrosie
Componenten......................... 2
• Unieke flexibiliteit
• Superieure mechanische bestendigheid Mengverhouding
• Geschikt voor cryogene toepassingen Naar volume ........................ 2,33 deel A tot 1 deel B
Naar gewicht........................ 3,25 deel A tot 1 deel B
• Voldoet aan international normen voor
brandwerendheid
Doorharding............................ chemische reactie tussen
componenten
Typische toepassingen
Pitt-Char XP brandwerende epoxycoating heeft uitstekende Gewichtspercentage vaste stof 100%
brandwerende eigenschappen. Bij blootstelling aan vuur Oplosmiddelgehalte*
verandert het oppervlak door de unieke chemische EC SED 1999/13/EC ........... 0 g/kg (0 g/l)
samenstelling van het product in een keramiekachtige, UK PG6/23(92) bijlage 3...... 0 g/l (0 lbs/gal)
isolerende laag. Deze laag biedt een thermische
bescherming van de ondergrond, zelfs bij koolwaterstof- en Droge-laagdikte ...................... afhankelijk van brandcategorie en
vliegtuigbranden. profielfactor
Omdat Pitt-Char een epoxy is, vormt zijn taaie, duurzame Natte-laagdikte per laag ......... 6 - 8 mm (0,25 - 0,30 inch)
coating een ondoordringbaar schild tegen de elementen.
Pitt-Char XP is bestand tegen oplosmiddelen, zout Typisch rendement
2 2
oplossingen, loog en zuren en is slijtvast, waardoor Pitt- Bij 5 mm/0,2” ..................... 0,25 m /l 10,33 ft /gal
2 2
Char XP de ideale keuze is voor extreme omstandigheden, Bij 10 mm/0,4”...................... 0,12 m /l 5,17 ft /gal
van arctische tot tropische klimaten. Neem voor
Vlampunten ............................
gebruikstoepassingen boven 80 °C (176 °F) contact op met Verharder............................. boven 100 °C (212 °F)
uw vertegenwoordiger van PPG Protective & Marine Basis component ................. boven 100 °C (212 °F)
Coatings. Pitt-Char coatings hebben zich over de hele Verdunner type 47 ............... 44 °C 111 °F
wereld bewezen in raffinaderijen, chemische fabrieken, Amercoat 12 ........................ 24 °C 75 °F
offshore-platforms en bij verschillende andere verhoogd Amercoat 920 ...................... 24 °C 75 °F
risico toepassingen.
Verdunner............................... verdunner type 47
Applicatiemethode
Pitt-Char FM™ Fabric Mesh
Het opbrengen van het Pitt-Char XP-systeem vereist
een gedetailleerde kennis van applicatie-apparatuur,
componenten, omstandigheden, configuraties en het
opbrengen van deklagen. Neem contact op met uw
vertegenwoordiging van PPG Protective & Marine
Coatings voor informatie over ons
Mesh- Beschrijving Afmetingen rol Toepassingen
trainingsprogramma voor aannemers. code
Fiberglas, Rollen 1,2 x 45,7 m (4 x Cellulose en
238-2/66 openingen 1/8 x 150 ft), oppervlak per rol koolwaterstof
1/8", 152,55 g/m2 55,7 m2 (600 ft2) brandenden,
(4,5 oz/yd2) staalconstructies (kleine
delen)
Fiberglas, Rollen 1,2 x 45,7 m (4 x Koolwaterstof- en
238-4/66 openingen ¼ x ¼", 150 ft), vliegtuigbranden (30 min.
152,55 g/m2 (4,5 oppervlak per rol 55,7 m2 of korter) Alle staaldelen
oz/yd2) (600 ft2) met grotere afmetingen.
Pitt-Char FM fabric Rol 1 x 50 m (40’ x 166 ft.) Koolwaterstof- en
238-5/66 mesh 203,4 g/m2 vliegtuigbranden. Alle
oppervlak per rol 50 m2
(6,0 oz/yd2) (533 ft2) staaldeel afmetingen.
Verkoopvoorwaarden
Op al onze transacties zijn onze verkoopvoorwaarden
van toepassing
Productinformatie/
Applicatie-instructies
Technische gegevens
APPROVED PRODUCT
CF 459
Applicatiemethoden
Verwerking met spuitapparatuur geeft het gladste oppervlak.
Verwerking met een kwast geeft een oppervlaktestructuur.
AIRLESS SPUITEN - Gebruik een pomp die een druk van ten
minste 2800 psi (200 kg/cm²) aan de spuittip kan leveren. Een
30 mesh/500 micron intern filter wordt aanbevolen. Tipgrootte
tussen 0,019 en 0,025 inch (0,48 - 0,63 mm). De droge-
laagdikte van de eerste laag mag niet meer dan 1,5 mm
bedragen. Latere lagen mogen na 8 uur drogen bij 20°C/68°F
worden opgebracht met een maximale droge-laagdikte van 1,0
mm per laag.
KWAST - Gelijkmatig opbrengen met een schone, goed in het
product gedompelde kwast, met een droge-laagdikte van max.
300 micron per laag. Laat het product ten minste 2 uur bij
20°C/68°F drogen, alvorens een nieuwe laag aan te brengen.
Droogeigenschappen
De droogtijden kunnen sterk verschillen, afhankelijk van de
omgevingscondities, de applicatiemethode, de profielfactor-
waarden (A/V m-1 (Hp/A) van de te coaten staaldelen en de
opgebrachte laagdikte.
Als richtlijn kan worden aangehouden dat bij 15°C/59°F een
coating met een droge-laagdikte van 400 micron na ca. 1 uur
stofdroog en na ca. 40 uur doorgedroogd is. Voor nadere
informatie over de droogtijden van Steelguard FM 549 zie de
tabellen met droogtijden of raadpleeg uw PPG-
vertegenwoordiger.
Afschilderen
De standaard aanbevolen deklaag voor Steelguard FM 549 is
Steelguard 2458 welke snelle overcoating toestaat en snelle
voortgang van het project. Andere goedgekeurde deklagen zijn
Amercoat 450S, Amercoat 4310, Amercoat 2136 en PSX 700#.
Een deklaag voor toepassing in C1 omstandigheden binnen is
niet nodig, tenzij voor cosmetische redenen.
Bij toepassing in C2-omstandigheden BINNEN moet
Steelguard FM 549 worden overgeschilderd met Steelguard
2458, met een droge-laagdikte van 60 micron of met andere
goedgekeurde topcoats.
Raadpleeg uw PPG vertegenwoordiger voor specifieke
aanbevelingen.
Applicatiemethode:
1. Spoel de apparatuur vóór gebruik met de aanbevolen
reiniger.
2. Roer het product met een krachtige menger tot een
gelijkmatige consistentie is verkregen.
3. Verdunnen is doorgaans niet nodig.
4. Breng bij airless spuiten een natte laag aan in regelmatige,
evenwijdige banen. Overlap elke vorige baan met 50%, om
niet geraakte plaatsen, pinholes of heilige dagen te
voorkomen.
5. Besteed extra aandacht aan lasnaden, ruwe plekken,
scherpe randen en hoeken, klinknagels, bouten etc.
6. Een natte-laagdikte van 370 µm zal doorgaans resulteren in
een droge-laagdikte van 250 µm.
7. Controleer de droge-laagdikte met een niet-destructieve
droge-laagdiktemeter, zoals Mikrotest of Elcometer.
Breng extra materiaal aan indien de dikte minder is dan
voorgeschreven.
8. Kleine beschadigde of niet geraakte plaatsen, pinholes of
heilige dagen kunnen met de kwast worden bijgewerkt.
Repareer grotere oppervlakken met behulp van spuit of
kwast met Steelguard FM 549. Kleinere beschadigingen
met behulp van plekspaan, mes of spatel met Steelguard
2450 reparatieplamuur bijwerken.
9. Tijdens applicatie en droging dient in afgesloten ruimten
met verse lucht te worden geventileerd, totdat alle
oplosmiddelen zijn verdwenen. De temperatuur en relatieve
vochtigheid van de verse lucht dienen zodanig te zijn, dat
zich op het oppervlak geen condens kan vormen.
10. Reinig alle apparatuur met aanbevolen reiniger onmiddellijk
na gebruik of uiterlijk aan het eind van iedere werkdag of
werktijd.
Verkoopvoorwaarden
Op al onze transacties zijn onze verkoopvoorwaarden
van toepassing
Productinformatie/
Applicatie-instructies Technische gegevens
Uiterlijk.................................... mat
• Brandwerende dunne-laag-coating op Kleur ...................................... wit, grijs
oplosmiddelbasis
Componenten......................... 1
• Getest volgens internationale normen op
brandwerendheid Vaste-stofgehalte* ................. 68±3%
• Maximaal 2 uur brandwering op
Oplosmiddelengehalte**
staalconstructies EC SED 1999/13/EC ........... 293 g/kg (377 g/l)
• Verwerking op locatie of als UK PG6/23 (92) Appendix 3 325 g/l (2.7 lbs/gal)
preconstructiecoating
Droging................................... verdampen van oplosmiddelen
• Maximaal 1,5 mm droge-laagdikte in één enkele
laag Benodigde laagdikte............... Vereiste droge-laagdiktenodig voor
• Snelle applicatie de voorgeschreven brandwerendheid wordt bepaald middels
profielfactor en temperatuur afhankelijke laagdikte tabellen. Vraag
• Voor gebruik in C1, C2, C3 en C4 binnen en uw PPG-vertegenwoordiger om de volledige informatie.
buiten omgevingen. - Geen deklaag nodig voor
droge C1-omstandigheden binnen (ISO 12944) Droge-laagdikte (µm) ............ 250 400 500 700 1000 1500
APPROVED PRODUCT
CF 456
Voorbehandeling
Kan worden aangebracht op gestraald staal voorzien van de juiste
primer. Het oppervlak moet direct voorafgaande aan het
Applicatiegegevens
aanbrengen van de coating droog en vrij van stof, zout, vet of Ondergrond ............................ met primer voorbehandeld staal
andere verontreinigingen zijn. De primer moet worden aangebracht
volgens de specifieke instructies in de technische Applicatiemethoden................ airless spuiten, kwast
productinformatie. De primer moet geschikt zijn en door PPG
toegelaten als ondergrond voor Steelguard FM 550. De totale Omgevingscondities
droge-laagdikte van primerlagen mag niet meer dan 150 micron Relatieve vochtigheid........... tot 85%
bedragen. Temperatuur van de ondergrond 5 - 50ºC 41 - 122ºF
De maximaal toegestane droge laagdikte van epoxy primers kan Luchttemperatuur................. 5 - 50°C 41 - 122°F
worden verhoogd, raadpleeg uw PPG vertegenwoordiger voordat
de brandwerende coating wordt aangebracht. De temperatuur van de ondergrond moet bovendien ten minste 3°C
Als preconstructiesysteem kan Steelguard FM 550 direct op de /5ºF boven het dauwpunt liggen.
gestraalde ondergrond worden aangebracht, mits het toegepaste
staal voor droge C1-omstandigheden binnen bestemd is en de Verwerkingstijd ...................... niet beperkt
droge laagdikte boven de 400 µm is.
Het staal moet worden gestraald volgens ISO 8501-1 (klasse Sa Verdunner .............................. normaal niet nodig
2½) met een straalprofiel van ca. 50 - 75 micron, met een Indien nodig kan Amercoat 65 worden gebruikt (tot 5 volume %).
maximum van 100 micron. Breng Steelguard FM 550 zo snel Natte/droge laagdikte meetresultaten zullen dan afwijken en een
mogelijk na de voorbehandeling van de ondergrond op, om lagere maximale laagdiktevorming als resultaat moet worden
verontreiniging te voorkomen. Behandel het gestraalde staal nog overwogen.
dezelfde dag. Indien verontreiniging is opgetreden, dient deze te
worden verwijderd. Indien nodig, staal plaatselijk aanstralen. Het Reiniger ................................. Amercoat 65
oppervlak moet direct voorafgaande aan het aanbrengen van de
coating droog en vrij van stof, zouten, vet en andere
verontreinigingen zijn.
Mengen
Voor gebruik goed mengen, tot het product een volledig
gelijkmatige consistentie heeft. Tijdens het mengen ontstaat een
schijnbaar verdunnend effect, wat gebruikelijk is voor dit
product. Maak gebruik van een mechanische mixer.
Applicatiemethoden
Verwerking met spuitapparatuur geeft het gladste oppervlak.
Verwerking met een kwast geeft een oppervlaktestructuur.
AIRLESS SPUITEN - Gebruik een pomp die een druk van ten
minste 2800 psi (200 kg/cm²) aan de spuittip kan leveren. Een 30
mesh / 500 micron intern filter wordt aanbevolen. Tipgrootte tussen
0,019 en 0,033 inch (0,48 - 0,83 mm). Bij applicatie in de
werkplaats wordt aanbevolen om het product op te brengen met
een droge-laagdikte van 700 micron, met een droogtijd van ten
minste 8 uur bij 15°C59ºF tussen de afzonderlijke lagen.
Bij verwerking op locatie kunnen hogere droge laagdiktes
aangebracht worden in 1 laag. Aanbevolen wordt dat de droge
laagdikte van de eerste laag niet meer dan 1.5 mm bedraagt. Als
richtlijn voor volgende lagen geldt dat deze kunnen worden
aangebracht na 8 uur bij 20°C/68°F tot een maximale droge
laagdikte van 1.0 mm per laag.
KWAST - Gelijkmatig opbrengen met een schone, goed in het
product gedompelde kwast, met een droge-laagdikte van max. 300
micron per laag. Laat het product ten minste 2 uur bij 20 C/68ºF
drogen, alvorens een nieuwe laag aan te brengen.
Droogeigenschappen
De droogtijden kunnen sterk verschillen, afhankelijk van de
omgevingscondities, de applicatiemethode, de omstandigheden
tijdens het voorverwarmen en het geforceerd drogen (indien
-1
toegepast), de profielfactorwaarden (A/V m (Hp/A)) van de te
coaten staaldelen en de opgebrachte laagdikte.
Als richtlijn kan worden aangehouden dat bij 15°C/59ºF een coating
met een droge-laagdikte van 400 micron na ca. 1 uur stofdroog en
na ca. 40 uur doorgedroogd is. Voor nadere informatie over de
droogtijden van Steelguard FM 550 zie de tabellen met droogtijden
van het product of raadpleeg uw PPG-vertegenwoordiger.
Afschilderen
De standaard aanbevolen deklaag voor Steelguard FM 550 is Verzendgegevens
Steelguard 2458 welke snelle overcoating toestaat en snelle
voortgang van het project. Andere goedgekeurde deklagen zijn Verpakking ............................. 20 en 200 liter
Amercoat 450S,Amercoat 4310, Amercoat 2136 en PSX 700#. Een
deklaag voor toepassing in C1 omstandigheden binnen is niet Verzendgewicht ..................... ca. 29 kg (20 l)
nodig, tenzij voor cosmetische redenen.
Bij toepassing in C2-omstandigheden BINNEN moet Steelguard Houdbaarheid ........................ 1 jaar vanaf verzenddatum, mits
FM 550 worden overgeschilderd met Steelguard 2458, met een binnen opgeslagen in ongeopende,
droge-laagdikte van 60 micron of met andere goedgekeurde originele verpakking bij 5 tot 40°C
topcoats. (41 - 104ºF).
Raadpleeg uw PPG vertegenwoordiger voor specifieke
aanbevelingen.
Het is van belang dat de voorgeschreven brandwerende laagdikte
is bereikt voordat er een topcoat aangebracht wordt.
# Amercoat 71TC benodigd als deklaag.
Applicatiemethode:
1. Spoel de apparatuur vóór gebruik met de aanbevolen reiniger.
2. Roer het product met een krachtige menger tot een
gelijkmatige consistentie is verkregen.
3. Verdunning is doorgaans niet noodzakelijk bij airless spuiten.
4. Breng bij airless spuiten een natte laag aan in regelmatige,
evenwijdige banen. Overlap elke vorige baan met 50%, om
niet geraakte plaatsen, pinholes of heilige dagen te
voorkomen.
5. Besteed extra aandacht aan lasnaden, ruwe plekken,
scherpe randen en hoeken, klinknagels, bouten etc.
Een natte-laagdikte van 590 µm zal doorgaans resulteren in
een droge-laagdikte van 400 µm.
6. Controleer de droge-laagdikte met een niet-estructieve droge-
laagdiktemeter, zoals Mikrotest of Elcometer. Breng extra
materiaal aan indien de dikte minder is dan voorgeschreven.
7. Kleine beschadigde of niet geraakte plaatsen, pinholes of
heilige dagen kunnen met de kwast worden bijgewerkt.
Repareer grotere oppervlakken met behulp van spuit of kwast
met Steelguard FM 550. Kleinere beschadidingen met behulp
van plekspaan, mes of spatel met Steelguard 2450
reparatieplamuur bijwerken.
8. Beschadigde delen zonder primer waarbij blank staal blootligt,
moeten met een geschikte primer worden gerepareerd voordat
de brandwerende coating opnieuw wordt opgebracht.
9. Tijdens applicatie en droging dient in afgesloten ruimten met
verse lucht te worden geventileerd, totdat alle oplosmiddelen
zijn verdwenen. De temperatuur en relatieve vochtigheid van
de verse lucht dienen zodanig te zijn, dat zich op het oppervlak
geen condens kan vormen.
10. Reinig alle apparatuur met aanbevolen reiniger onmiddellijk na
gebruik of uiterlijk aan het eind van iedere werkdag of werktijd.
Lees de informatie op het etiket en de veiligheidsvoorschriften van
het betreffende materiaal, voordat u het product verwerkt.
Verkoopvoorwaarden
Op al onze transacties zijn onze verkoopvoorwaarden
van toepassing
Productinformatie/
Applicatie-instructies Technische gegevens
Uiterlijk wanneer droog........... mat
GOEDGEKEURD PRODUCT
CF 551
Mengen
Voor gebruik goed mengen, totdat het product een volledig
gelijkmatige consistentie heeft. Dit kan een schijnbaar verdunnend
effect veroorzaken, wat voor dit product normaal is. Gebruik een
mechanische menger.
Applicatiemethoden
AIRLESS SPUITEN - Gebruik een pomp die een druk van ten
minste 2800 psi (200 kg/cm²) aan de spuitmond kan leveren. Een
30 mesh / 500 micron intern filter wordt aanbevolen. Spuitopening
tussen 19 en 25 inch (0,48 - 0,63 mm). Voor verwerking op locatie
kan Steelguard 551 worden toegepast in één enkele laag tot een
droge-laagdikte van 1,5 mm. Bij toepassing als
preconstructiecoating wordt aanbevolen om het product op te
brengen met een droge-laagdikte van 700 micron, met een
droogtijd van ten minste 8 uur bij 15 °C (59 °F) tussen de
afzonderlijke lagen.
KWAST - Gelijkmatig opbrengen met een schone, goed in het
product gedompelde kwast, met een droge-laagdikte van max. 300
micron per laag. Laat het product ten minste 2 uur drogen bij 20 °C
(68 °F) alvorens een nieuwe laag aan te brengen.
Droogeigenschappen
De droogtijden kunnen sterk verschillen, afhankelijk van de
-1
omgevingscondities, A/V m (Hp/A) van de te coaten gedeeltes en
de opgebrachte laagdikte. Als richtlijn kan worden aangehouden
dat bij 15 °C (59 °F) een coating met een droge-laagdikte van 700
micron binnen 1 uur stofdroog en na ca. 40 uur doorgedroogd is.
Zie de tabellen met droogtijden van het product of raadpleeg uw
PPG-vertegenwoordiger voor nadere informatie over de droogtijden
van Steelguard 551.
Overschilderen
De standaard aanbevolen deklaag voor Steelguard 551 is
Steelguard 2458, die snel overschilderbaar is en snel kan worden
verwerkt. Andere goedgekeurde deklagen, echter met langere
overschilderbaarheidsperioden, zijn de producten uit de Amercoat
450-serie, Amercoat 4310, Amercoat 2136 en PSX 700*. Er is geen
sealer nodig voor droge C1-bedrijfsomstandigheden, tenzij uit
cosmetische overwegingen.
Applicatiemethode:
1. Spoel de apparatuur vóór gebruik met de aanbevolen reiniger.
2. Roer het product met een mechanische menger tot een
gelijkmatige consistentie is verkregen.
3. Verdunning is doorgaans niet noodzakelijk bij airless spuiten.
4. Bij airless spuiten een natte laag in regelmatige, evenwijdige
banen aanbrengen. Overlap elke vorige baan met 50%, om
niet-geraakte plaatsen, pinholes of heilige dagen te
voorkomen.
5. Besteed speciale aandacht aan lasnaden, ruwe plekken,
scherpe randen en hoeken, klinknagels, bouten etc.
6. Een natte-laagdikte van 540 micron zal doorgaans
resulteren in een droge-laagdikte van 400 micron.
7. Controleer de droge-laagdikte met een niet-destructieve
droge-laagdiktemeter, zoals Mikrotest of Elcometer. Breng
extra materiaal aan indien de dikte minder is dan
voorgeschreven.
8. Beperkte beschadigde oppervlakken dienen te worden
gerepareerd met Steelguard 2451 brandwerend
reparatiemiddel met de voorgeschreven droge-filmdikte.
Repareer grotere oppervlakken met behulp van
spuitapparatuur of kwast met Steelguard 551.
9. Beschadigde systemen zonder primer waarbij blank staal
blootligt, moeten met een geschikte primer worden
gerepareerd voordat de brandwerende coating opnieuw wordt
opgebracht.
10. In afgesloten ruimten dient tijdens applicatie en droging met
schone lucht te worden geventileerd,
totdat alle oplosmiddelen zijn verdwenen. De temperatuur en
vochtigheid van de verse lucht dienen zodanig te zijn, dat zich
op het oppervlak geen condens kan vormen.
11. Reinig alle apparatuur met aanbevolen reiniger
onmiddellijk na gebruik of uiterlijk aan het eind van iedere
werkdag of werktijd.
Verkoopvoorwaarden
Op al onze transacties zijn onze verkoopvoorwaarden
van toepassing
Componenten......................... 1
• Brandwerende coating op oplosmiddelbasis
• Sneldrogend en daardoor sneller hanteerbaar Vaste-stofgehalte* ................ 68±3%
• Getest volgens internationale normen op Oplosmiddelengehalte**
brandwerendheid EC SED 1999/13/EC ........... 294 g/kg (377 g/l)
• Maximaal 2 uur brandwering op staalconstructies UK PG6/23 (92) Appendix 3 325 g/l (2.7 lbs/gal)
• Verwerking op locatie of als preconstructiecoating
Droging................................... verdampen van oplosmiddelen
• Maximaal 1,0 mm droge-laagdikte in één enkele laag
• Voor gebruik in C1, C2, C3 en C4 binnen en buiten Benodigde laagdikte: Vereiste droge-laagdikte nodig voor de
omgevingen. - Geen deklaag nodig voor droge C1- voorgeschreven brandwerendheid die wordt bepaald middels
-1
omstandigheden binnen (ISO 12944) profielfactor (A/V m (HP/A)) en temperatuurafhankelijke laagdikte
tabellen. Vraag uw PPG-vertegenwoordiger om de volledige
informatie.
Typische toepassingen Droge-laagdikte (µm) ............ 250 400 500 700 1000
Brandwering voor staalconstructies binnen en buiten.
Sneldrogende variant van Steelguard 550, toegepast als Natte-laagdikte (µm) .............. 370 590 740 1030 1470
preconstructiesysteem met behulp van standaard airless 2
Theoretisch rendement (m /l).. 2,72 1,70 1,36 0,97 0,68
spuitapparatuur. Door de snelle droging kunnen met
Steelguard 560 gecoate staaldelen snel worden (de opgegeven natte-laagdiktes zijn theoretische waarden voor één
gehanteerd en treed minder mechanische schade op in de airless opgebrachte spuitlaag)
constructiefase. Tevens geschikt voor verwerking op
locatie. Soortelijk gewicht ................... 1,3 kg/l
APPROVED PRODUCT
CF 457
Mengen
Voor gebruik goed mengen, totdat het product een volledig
gelijkmatige consistentie heeft. Tijdens het mengen ontstaat
een schijnbaar verdunnend effect, wat gebruikelijk is voor dit
product. Maak gebruik van een mechanische mixer.
Applicatiemethoden
AIRLESS SPUITEN - Gebruik een pomp die een druk van ten
minste 2800 psi (200 kg/cm²) aan de spuittip kan leveren. Een
30 mesh / 500 micron intern filter wordt aanbevolen. Tipgrootte
tussen 0,019 en 0,025 inch (0,48 - 0,63 mm). Bij applicatie in
de werkplaats wordt aanbevolen om het product op te brengen
met een droge-laagdikte van 700 micron, met een droogtijd van
ten minste 6 uur bij 15°C/59ºF tussen de afzonderlijke lagen.
KWAST – Alleen geschikt voor kleine oppervlakken, zoals bij
reparaties. Gelijkmatig opbrengen met een schone, goed in het
product gedompelde kwast, met een droge-laagdikte van max.
300 micron per laag. Laat het product ten minste 2 uur bij 20°C
/68ºF drogen, alvorens een nieuwe laag aan te brengen.
Droogeigenschappen
Afschilderen
De standaard aanbevolen deklaag voor Steelguard 560 is
Steelguard 2458 welke snelle overcoating toestaat en snelle Verzendgegevens
voortgang van het project. Andere goedgekeurde deklagen zijn
Amercoat 450S,Amercoat 4310, Amercoat 2136 en PSX 700#. Een Verpakking ............................. 20 en 200 liter
deklaag voor toepassing in C1 omstandigheden binnen is niet
nodig, tenzij voor cosmetische redenen. Verzendgewicht ..................... ca. 29 kg (20 l)
Bij toepassing in C2-omstandigheden BINNEN moet Steelguard
560 worden overgeschilderd met Steelguard 2458, met een droge- Houdbaarheid ........................ 1 jaar vanaf verzenddatum, mits
laagdikte van 60 micron of met andere goedgekeurde topcoats. binnen opgeslagen in ongeopende,
Raadpleeg uw PPG vertegenwoordiger voor specifieke originele verpakking bij 5 tot 40°C
aanbevelingen. (41 tot 104°F).
Het is van belang dat de voorgeschreven brandwerende laagdikte
is bereikt voordat er een topcoat aangebracht wordt.
# Amercoat 71TC benodigd als deklaag.
Applicatiemethode
1. Spoel de apparatuur vóór gebruik met de aanbevolen reiniger.
2. Roer het product met een mechanische mixer tot een
gelijkmatige consistentie is verkregen.
3. Verdunning is doorgaans niet noodzakelijk bij airless spuiten.
4. Breng bij airless spuiten een natte laag aan in regelmatige,
evenwijdige banen. Overlap elke vorige baan met 50%, om niet
geraakte plaatsen, pinholes of heilige dagen te voorkomen.
5. Besteed extra aandacht aan lasnaden, ruwe plekken, scherpe
randen en hoeken, klinknagels, bouten etc.
6. Een natte-laagdikte van 590 µm zal doorgaans resulteren
in een droge-laagdikte van 400 µm.
7. Controleer de droge-laagdikte met een niet-destructieve droge-
laagdiktemeter, zoals Mikrotest of Elcometer. Breng extra
materiaal aan indien de dikte minder is dan voorgeschreven.
8. Kleine beschadigde of niet geraakte plaatsen, pinholes of
heilige dagen kunnen met de kwast worden bijgewerkt.
Repareer grotere oppervlakken met behulp van spuit of kwast
met Steelguard 560. Kleinere beschadigingen met behulp van
plekspaan, mes of spatel met Steelguard 2450
reparatieplamuur bijwerken.
9. Beschadigde delen zonder primer waarbij blank staal blootligt,
moeten met een geschikte primer worden gerepareerd voordat
de brandwerende coating opnieuw wordt opgebracht.
10. Tijdens applicatie en droging dient in afgesloten ruimten met
verse lucht te worden geventileerd, totdat alle oplosmiddelen
zijn verdwenen. De temperatuur en relatieve vochtigheid van
de verse lucht dienen zodanig te zijn, dat zich op het oppervlak
geen condens kan vormen.
11. Reinig alle apparatuur met aanbevolen reiniger onmiddellijk na
gebruik of uiterlijk aan het eind van iedere werkdag of werktijd.
Verkoopvoorwaarden
Op al onze transacties zijn onze verkoopvoorwaarden
van toepassing
Productinformatie/
Applicatie-instructies Technische gegevens
Uiterlijk wanneer droog........... mat
GOEDGEKEURD PRODUCT
CF 550
Mengen
Voor gebruik goed mengen, totdat het product een volledig
gelijkmatige consistentie heeft. Dit kan een schijnbaar verdunnend
effect veroorzaken, wat voor dit product normaal is. Gebruik een
mechanische menger.
Applicatiemethoden
AIRLESS SPUITEN - Gebruik een pomp die een druk van ten
minste 2800 psi (200 kg/cm²) aan de spuitmond kan leveren. Een
30 mesh / 500 micron intern filter wordt aanbevolen. Spuitopening
tussen 19 en 25 inch (0,48 - 0,63 mm). Bij toepassing als
preconstructiecoating wordt aanbevolen om het product op te
brengen met een droge-laagdikte van 700 micron, met een
droogtijd van ten minste 6 uur bij 15 °C (59 °F) tussen de
afzonderlijke lagen.
KWAST – Alleen geschikt voor kleine oppervlakken, zoals bij
reparaties. Gelijkmatig opbrengen met een schone, goed in het
product gedompelde kwast, met een droge-laagdikte van max. 300
micron per laag. Laat het product ten minste 2 uur drogen bij 20 °C
(68 °F) alvorens een nieuwe laag aan te brengen.
Droogeigenschappen
De droogtijden kunnen sterk verschillen, afhankelijk van de
-1
omgevingscondities, A/V m (Hp/A) van de te coaten gedeeltes en
de opgebrachte laagdikte. Als richtlijn kan worden aangehouden
dat bij 15 °C (59 °F) een coating met een droge-laagdikte van 700
micron binnen 30 minuten stofdroog en na ca. 20 uur
doorgedroogd is. Zie de tabellen met droogtijden van het product of
raadpleeg uw PPG-vertegenwoordiger voor nadere informatie over
de droogtijden van Steelguard 561.
Overschilderen
De standaard aanbevolen deklaag voor Steelguard 561 is
Steelguard 2458, die snel overschilderbaar is en snel kan worden
verwerkt. Andere goedgekeurde deklagen, echter met langere
overschilderbaarheidsperioden, zijn de producten uit de Amercoat
450-serie, Amercoat 4310, Amercoat 2136 en PSX 700*. Er is geen
sealer nodig voor droge C1-bedrijfsomstandigheden, tenzij uit
cosmetische overwegingen. Voor droge C2-bedrijfs-
omstandigheden moet Steelguard 561 worden voorzien van een
goede deklaag Steelguard 2458 met een droge-filmdikte van 60
Applicatiemethode:
1. Spoel de apparatuur vóór gebruik met de aanbevolen reiniger.
2. Roer het product met een mechanische menger tot een
gelijkmatige consistentie is verkregen.
3. Verdunning is doorgaans niet noodzakelijk bij airless spuiten.
4. Bij airless spuiten een natte laag in regelmatige, evenwijdige
banen aanbrengen. Overlap elke vorige baan met 50%, om
niet-geraakte plaatsen, pinholes of heilige dagen te
voorkomen.
5. Besteed speciale aandacht aan lasnaden, ruwe plekken,
scherpe randen en hoeken, klinknagels, bouten etc.
6. Een natte-laagdikte van 540 micron zal doorgaans
resulteren in een droge-laagdikte van 400 micron.
7. Controleer de droge-laagdikte met een niet-destructieve
droge-laagdiktemeter, zoals Mikrotest of Elcometer. Breng
extra materiaal aan indien de dikte minder is dan
voorgeschreven.
8. Beperkte beschadigde oppervlakken dienen te worden
gerepareerd met Steelguard 2451 brandwerend
reparatiemiddel met de voorgeschreven droge-filmdikte.
Repareer grotere oppervlakken met behulp van airless
spuitapparatuur met Steelguard 561.
9. Beschadigde systemen zonder primer waarbij blank staal
blootligt, moeten met een geschikte primer worden
gerepareerd voordat de brandwerende coating opnieuw wordt
opgebracht.
10. Tijdens applicatie en droging dient in afgesloten ruimten met
schone lucht te worden geventileerd,
totdat alle oplosmiddelen zijn verdwenen. De temperatuur en
vochtigheid van de verse lucht dienen zodanig te zijn, dat zich
op het oppervlak geen condens kan vormen.
11. Reinig alle apparatuur met aanbevolen reiniger
onmiddellijk na gebruik of uiterlijk aan het eind van iedere
werkdag of werktijd.
Verkoopvoorwaarden
Op al onze transacties zijn onze verkoopvoorwaarden
van toepassing
Componenten......................... 1
• Dunne-laag opschuimende coating op
waterbasis voor applicatie op locatie Vaste-stofgehalte* ................. 70±3%
• Milieuvriendelijk product met gering Oplosmiddelengehalte**
oplosmiddelengehalte en lage geuremissie EC SED 1999/13/EC ........... 20 g/kg (28 g/l)
• Chloorvrij UK PG6/23(92) Appendix 3 . 50g/l
• Getest volgens internationale normen voor Droging................................... verdamping van water en polymeer
brandwerendheid verbinding
• Maximaal 1 uur brandwering op
Benodigde laagdikte............... Vereiste droge laagdikte voor de
staalconstructies voorgeschreven brandwerendheid wordt bepaald middles
• Voor droge C1-omstandigheden binnen (ISO profielfactor en temperatuurafhankelijke laagdikte tabellen. Vraag
12944) uw PPG-vertegenwoordiger om de olledige informatie.
• Maximaal 700 micron droge-laagdikte per laag Droge-laagdikte (µm) ............ 250 400 500 700
• Snelle applicatie
Natte-laagdikte (µm) .............. 360 570 715 1000
APPROVED PRODUCT
CF 458
Droogeigenschappen
De droogtijden kunnen sterk verschillen, afhankelijk van de
omgevingscondities, de luchtverplaatsing, de applicatiemethode,
-1
de profielfactorwaarden (A/V m (Hp/A) van de te coaten gedeeltes
en de opgebrachte laagdikte. Als richtlijn kan worden aangehouden
dat bij 20°C/68ºF en een relatieve vochtigheid van 50% een coating
met een droge-laagdikte van 400 micron na ca. 2 uur stofdroog en
na ca. 4 uur doorgedroogd is. Voor nadere informatie over de
droogtijden van Steelguard FM 580 zie de tabellen met droogtijden
of raadpleeg uw PPG-vertegenwoordiger.
Afschilderen
Hoewel er voor C1-omstandigheden binnen geen
beschermende deklaag nodig is, worden voor decoratieve
doeleinden de watergedragen deklagen van de Amercoat 220-
serie producten aanbevolen. Steelguard FM 585 mag pas na
ten minste 4 uur bij 20°C/68°F met Amercoat 220 worden
overgeschilderd. Raadpleeg uw PPG-vertegenwoordiger voor
details betreffende andere aanbevolen deklagen zoals
Steelguard 2458.
Het is van belang dat de voorgeschreven brandwerende
laagdikte is bereikt voordat er een topcoat aangebracht wordt.
Applicatiemethode
1. Reinig de apparatuur vóór gebruik met een geschikt Verzendgegevens
oplosmiddel en spoel deze vervolgens met schoon
Verpakking ............................. 20 liter
water.
2. Roer het product met een mechanische mixer tot een Verzendgewicht ..................... ca. 28 kg
gelijkmatige consistentie is verkregen. Er hoeft niet te
worden verdund. Houdbaarheid ........................ 1 jaar vanaf verzenddatum, mits
3. Breng bij airless spuiten een natte laag aan in binnen opgeslagen in ongeopende,
originele verpakking bij 5 tot 30°C
regelmatige, evenwijdige banen. Overlap elke vorige
(41 - 86ºF)
baan met 50%, om niet geraakte plaatsen, pinholes of
heilige dagen te voorkomen.
4. Besteed extra aandacht aan lasnaden, ruwe plekken,
scherpe randen en hoeken, klinknagels, bouten etc.
5. Een natte-laagdikte van 570 µm zal doorgaans
resulteren in een droge-laagdikte van 400 µm.
6. Controleer de droge-laagdikte met een niet-destructieve
droge-laagdiktemeter, zoals Mikrotest of Elcometer.
Breng extra materiaal aan indien de dikte minder is dan
voorgeschreven.
7. Kleine beschadigde of niet geraakte plaatsen, pinholes
of heilige dagen kunnen met de kwast worden
bijgewerkt. Repareer grotere oppervlakken met behulp
van spuitapparatuur, kwast of roller met Steelguard FM
580.
8. In afgesloten ruimten dient tijdens applicatie en droging
met droge lucht te worden geventileerd. De vochtigheid
moet onder 80% worden gehouden en de temperatuur
dient zodanig te zijn, dat zich op het oppervlak geen
condens kan vormen.
9. Reinig alle apparatuur met schoon water onmiddellijk na
gebruik of uiterlijk aan het eind van iedere werkdag of
werktijd.
Verkoopvoorwaarden
Op al onze transacties zijn onze verkoopvoorwaarden
van toepassing
Componenten ........................ 1
• Dunne-laag opschuimende coating op
waterbasis voor applicatie op locatie Hardingsmethode ................... verdamping van water en
polymeer-coalescentie
• Milieuvriendelijk product met gering
oplosmiddelengehalte en lage geuremissie Vaste-stofgehalte* ................. 70 ± 3%
• Chloorvrij
Oplosmiddelengehalte**
• Maximaal 1 uur brandwering op
staalconstructies EC SED 1999/13/EC .............. 20 g/kg (29 g/l)
• Voor droge C1-omstandigheden binnen (ISO
UK PG6/23(92) Appendix 3.... 30 g/l
12944)
• Max. 700 micron droge-laagdikte per laag Applicatie-eisen ...................... Ter vaststelling van de vereiste
droge-laagdikte voor de
• Snelle applicatie voorgeschreven brandwerendheid
-1
wordt er verwezen naar de A/V m -
Typische toepassingen (Hp/A) waarden van de betreffende
Brandwering door middel van schuimvorming voor producten of naar de
staalconstructies binnen in C1-omstandigheden volgens ISO desbetreffende tabellen met
12944, zoals kantoren, ziekenhuizen, scholen en winkels. maximaal toegestane
Doordat dit product watergedragen is en een bijzonder lage temperaturen. Vraag uw PPG-
geuremissie heeft, is het een milieuvriendelijker en veiliger vertegenwoordiger om de volledige
alternatief voor coatings op basis van oplosmiddelen die op informatie.
locatie in gesloten ruimten moeten worden opgebracht. Droge-laagdikte (µm) ............ 250 400 500 700
APPROVED PRODUCT
CF 460
Droogeigenschappen
De droogtijden kunnen sterk verschillen, afhankelijk van de
omgevingscondities, de luchtverplaatsing, de
applicatiemethode, de A/V m-1 (Hp/A) -waarden van de te
coaten gedeeltes en de opgebrachte laagdikte. Als richtlijn kan
worden aangehouden dat bij 20°C/68°F en een relatieve
vochtigheid van 50% een coating met een droge-laagdikte van
400 micron na ca. 2 uur stofdroog en na ca. 4 uur
doorgedroogd is. Voor nadere informatie over de droogtijden
van Steelguard FM 585 zie de tabellen met droogtijden of
raadpleeg uw PPG-vertegenwoordiger.
Overschilderen
Hoewel er voor C1-omstandigheden binnen geen
beschermende deklaag nodig is, worden voor decoratieve
doeleinden de watergedragen deklagen van de Amercoat 220-
serie producten aanbevolen. Steelguard FM 585 mag pas na
ten minste 4 uur bij 20°C/68°F met Amercoat 220 worden
overgeschilderd. Raadpleeg uw PPG-vertegenwoordiger voor
details betreffende andere aanbevolen deklagen zoals
Steelguard 2458.
Het is van belang dat de voorgeschreven brandwerende
laagdikte is bereikt voordat er een topcoat aangebracht wordt.
Verkoopvoorwaarden
Op al onze transacties zijn onze verkoopvoorwaarden
van toepassing
Productinformatie/
Applicatie-instructies Technische gegevens
Uiterlijk wanneer droog........... mat
• Brandwerend reparatiemiddel op basis van Kleur ....................................... wit
oplosmiddelen
Componenten......................... 1
• Tot 2 mm droge-laagdikte per laag
• De klus snel geklaard Doorharding............................ verdamping van oplosmiddelen
Vaste-stofgehalte* ................ 72 ± 3%
Typische toepassingen
Oplosmiddelengehalte**
Brandwerend vulmiddel voor reparatie ter plekke van EC SED 1999/13/EC ........... 233 g/kg (313g/l)
de brandwerende coatings Steelguard FM 549, 550 UK PG6/23(92) bijlage 3 ..... 275 g/l
en 560, op te brengen met behulp van plekspaan,
Bereik droge-laagdikte ........... 0,3 tot 2,0mm
plamuurmes of spatel voor kleine oppervlakken
waarbij bijwerken van het originele materiaal niet Laagdikte (in mm)................... droog nat
mogelijk is. 0,4 0,56
0,6 0,86
0,8 1,11
1,0 1,39
1,5 2,08
2,0 2,78
2
Theoretisch rendement .......... 0,72 m /l bij 1 mm droge-laagdikte
Applicatiemethode
Opbrengen met plekspaan, plamuurmes of spatel. De Verzendgegevens
aangebrachte coating dient het omringende gebied Grootte van de verpakking ..... 2,5 liter
wat te overlappen om de krimp tijdens het drogen te
compenseren. Verzendgewicht...................... ca. 5 kg
Verkoopvoorwaarden
Op al onze transacties zijn onze verkoopvoorwaarden
van toepassing
Product Data/
Application Instructions Physical Data
Uiterlijk wanneer droog........... mat
• Brandwerend reparatiemiddel op basis van Kleur ....................................... wit
oplosmiddelen
Componenten......................... 1
• Tot 2 mm droge-laagdikte per laag
• De klus snel geklaard Doorharding............................ verdamping van oplosmiddelen
Vaste-stofgehalte ................. 76 ± 3%
Typische toepassingen
Oplosmiddelengehalte*
Brandwerend vulmiddel voor reparatie ter plekke van
de brandwerende coatings Steelguard 551 en 561, op EC SED 1999/13/EC .............. 205 g/kg (286g/l)
te brengen met behulp van plekspaan, plamuurmes of
UK PG6/23(92) bijlage 3 ....... 251 g/l
spatel voor beperkte beschadigde oppervlakken
waarbij bijwerken van het originele materiaal niet Bereik droge-laagdikte ........... 0,3 tot 2,0mm
mogelijk is.
Laagdikte (in mm)................... droog nat
0,4 0,53
0,6 0,79
0,8 1,05
1,0 1,32
1,5 1,97
2,0 2,63
2
Theoretisch rendement .......... 0,76 m /l bij 1 mm droge-laagdikte
Vlampunt
(gesloten cup) ..................... ºC ºF
Steelguard 2451 .................. 26 79
Amercoat 65 ........................ 24 75
* De opgegeven oplosmiddelengehaltes zijn in overeenstemming
met de EU-richtlijn 1999/13/EC, die betrekking hebben op
theoretisch berekende waarden, en met de Britse richtlijn PG6/23
(92), bijlage 3, die betrekking hebben op in de praktijk vastgestelde
waarden
Applicatiemethode
Opbrengen met plekspaan, plamuurmes of spatel. De Shipping Data
aangebrachte coating dient het omringende gebied Grootte van de verpakking ..... 2,5 liter
wat te overlappen om de krimp tijdens het drogen te
compenseren. Verzendgewicht...................... ca. 5 kg
Verkoopvoorwaarden
Op al onze transacties zijn onze verkoopvoorwaarden
van toepassing
Dry film thickness (µm) .......... 250 400 500 700 1000
Approvals Wet film thickness (µm)
Steelguard FM 2570 has been tested to National and 373 597 746 1045 1493
2
International standards for cellulosic fire exposure (ISO Theoretical coverage (m /l) ….
2.68 1.68 1.34 0.96 0.67
834) and subsequently assessed and certified in
(wet film thicknesses quoted are
accordance with various National requirements. Please theoretical for one airless spray
contact your PPG Protective and Marine Coatings coat)
representative for latest information relating to local market
requirements and approvals. For given projects PPG Specific gravity ....................... 1.27 kg/l
Protective and Marine Coatings can provide customers with
Flashpoint
loading data and material consumption calculations
(closed cup) ......................... ºC ºF
stipulated by required fire protection, steel section Steelguard FM 2570 ......... 26 79
designation and local requirements. Standard loading tables Amercoat 12 ..................... 24 75
can be made available where applicable.
APPROVED PRODUCT
CF 542
Application Methods
AIRLESS SPRAY - Use a pump capable of producing a
minimum pressure at the tip of 2800 psi (200 kg/cm²). Tip
size 19-25 thou’ (0.48-0.63mm).
BRUSH – Suitable only for small areas such as repairs.
Apply evenly using a clean, well-loaded brush at up to
300microns dft per coat. Allow at least 4 hours drying at
20ºC/68ºF between coats.
Application Procedure:
1. Flush equipment with recommended cleaner before use. Shipping Data
2. Stir to an even consistency with a power mixer.
Pack size ................................ 20 litres
3. Thinning is normally not required for airless spray.
4. For airless spray apply a wet even coat in parallel Shipping weight ..................... approx. 27 kg (20 l)
passes. Overlap each pass 50% to avoid bare areas,
pinholes or holidays. Shelf life ................................. 12 months when stored indoors in
5. Give special attention to welds, rough spots, sharp unopened, original containers at 5
to 30°C (41 to 86ºF).
edges and corners, rivets, bolts, etc.
6. Application at 600 µm wet film thickness will normally
provide 400 µm dry film.
7. Check thickness of dry coating with a non- destructive
dry film thickness gauge, such as Mikrotest or
Elcometer. If less than specified thickness, apply
additional material as needed.
8. Small damaged or bare areas and random pinholes or
holidays can be touched up by brush. Repair larger
areas either by spray or brush with Steelguard FM 2570.
9. In confined areas ventilate with clean air during
application and drying until all solvents are removed.
Temperature and humidity of ventilating air must be
such that moisture condensation will not form on
surface.
10. Clean all equipment with recommended cleaner
immediately after use or at least at the end of each working
day or shift.
Before using the product, read the label on the can and
consult the material safety data sheet.
Verkoopvoorwaarden
Op al onze transacties zijn onze verkoopvoorwaarden
van toepassing
Primers
Amercoat 68E
Amercoat 68G
Amercoat 139
Steelguard 3290
> START
We Know...
Fire Protection
Coatings
Amercoat
Amercoat 68E
Zinkrijke epoxy primer (68 Series)
Productinformatie/
Applicatie-instructies
• Bevat minimaal 85% zinkgehalte bij gewicht in Technische gegevens
de droge laag
• Koppelt de taaiheid van epoxy aan de Uiterlijk ................................... mat
uitstekende beschermende eigenschappen van Kleur ...................................... roodachtig grijs
zink
• Uitstekende bestendigheid tegen de inwerking Componenten ........................ 2
van weer en wind Mengverhouding (volume)
• Uitstekende resultaten in zowel maritieme als hars ..................................... 4 delen
industriële omgevingen verharder ............................. 1 deel
• Kan eenvoudig met airless of conventionele Doorharding ........................... door verdampen van de
spuitapparatuur worden opgebracht oplosmiddelen en reactie tussen de
componenten
Algemene toepassingen In combinatie met een Vaste-stofgehalte .................. 57% (ISO 3233)*
geschikt deklaag systeem kan Amercoat 68E gebruikt
worden in de volgende toepassingen: VOC**
EC SED 1999/13/EC ........... 148 g/kg (410 g/l)
INDUSTRIEEL - Staalconstructies, machines, buizen UK PG6/23(92) Appendix 3 . 363 g/l (3.0 lbs/gal)
en de buitenkant van tanks in papierfabrieken,
olieraffinaderijen, krachtcentrales, chemische Droge-laagdikte ..................... 50-75 µm (2-3 mils) per laag
fabrieken en zuiveringsinstallaties. Aantal lagen .......................... 1
SCHEEPVAART - Dekken, rompen en bovenbouw
van schepen, aken en werkeilanden. Op pieren, Theoretisch rendement ......... 7,6 m²/l (bij 75 µm)
2
offshore-platforms en aanverwante constructies. 309,6 ft /gal (bij 3 mils)
Applicatiegegevens
Applicatiemethode
Amercoat 68E is verpakt in de juiste mengverhouding Verzendgegevens
in twee componenten (hars en verharder). Verpakking
Hars: 8 l (2,1 gal) in 10 l blik hars ................................ 8 l (2,1 gal) in 10 l blik
Verharder: 2 l (0,53 gal) in 2½ l blik verharder ........................ 2 l (0,53 gal) in 2½ l blik
1. Spoel de apparatuur vóór gebruik met Amercoat 9HF.
2. Roer de hars (in de grotere container) met een Verzendgewicht
mechanische menger tot een gelijkmatige consistentie is hars ................................ ca. 28 kg
verkregen. verharder ........................ ca. 2,5 kg
3. Voeg verharder aan de harsoplossing toe en blijf 5
minuten lang roeren. Zeef het materiaal met een 250 µm Houdbaarheid ................... 1 jaar vanaf verzenddatum,
(60 mesh) zeef om eventuele verstopping van de mits binnen opgeslagen in
apparatuur te voorkomen. OPMERKING: Omdat de ongeopende, originele
verwerkingstijd beperkt is en door hoge temperaturen verpakking bij 5 tot 40°C (41 tot
wordt verkort, dient slechts zoveel materiaal te worden 104°F)
gemengd als binnen 8 uur bij 20°C (68°F) kan worden
opgebracht.
4. Verdunning is doorgaans niet noodzakelijk bij airless
spuiten. Bij toepassing van conventionele
spuitapparatuur is verdunning alleen toegestaan om de
verwerkbaarheid van het materiaal te verbeteren; hierbij
mag niet meer dan 10 vol-% Amercoat 9HF worden
toegevoegd.
5. Tijdens het opbrengen van het product roeren om het
materiaal homogeen te houden. Breng een natte laag
aan in regelmatige, evenwijdige banen. Overlap elke
vorige baan met 50%, om niet geraakte plaatsen,
pinholes of heilige dagen te voorkomen.
6. Breng op alle lasnaden, ruwe plekken, scherpe randen
en hoeken, klinknagels, bouten etc. een dubbele
laagdikte aan.
7. Een natte-laagdikte van 132 µm (5,3 mils) zal
doorgaans resulteren in een droge-laagdikte van 75 µm
(3 mils). Voorkom overapplicatie dat kan resulteren in
verminderde cohesieve kracht wanneer overschilderd.
8. Controleer de droge-laagdikte met een niet-destructieve
droge-laagdiktemeter, zoals Mikrotest of Elcometer.
Breng extra materiaal aan indien de dikte minder is dan
voorgeschreven.
9. Kleine beschadigde of niet geraakte plaatsen en hier en
daar voorkomende pinholes of heilige dagen kunnen
met de kwast worden bijgewerkt. Werk grotere
oppervlakken met de spuit bij.
10. Tijdens applicatie en droging dient in afgesloten ruimten
met verse lucht te worden geventileerd, totdat alle
oplosmiddelen zijn verdwenen. De temperatuur en
vochtigheid van de verse lucht dienen zodanig te zijn,
dat zich op het oppervlak geen condens kan vormen.
11. Reinig alle apparatuur met Amercoat 9HF, onmiddellijk
na gebruik of uiterlijk aan het eind van iedere werkdag
of werktijd. Wanneer restanten van Amercoat 68E in de
spuitapparatuur achterblijven, zullen deze uitharden en
verstopping veroorzaken.
Veiligheid Aansprakelijkheidsbeperking
Omdat verkeerd gebruik en verkeerde handeling van dit De aansprakelijkheid van PPG voor welke vordering dan
product nadelige gevolgen voor de gezondheid kan hebben ook, waaronder begrepen vorderingen die hun oorzaak
en bovendien kan leiden tot brand of explosies, dienen de vinden in nalatigheid of onachtzaamheid van PPG, voor
bij de product data/applicatie-instructies en de bij het verlies of schade voortkomend uit, samenhangend met of
veiligheidsinformatieblad gevoegde veiligheidsinstructies ten gevolge van het gebruik van de producten, kan in geen
tijdens opslag, handeling, gebruik en drogen te worden geval de koopprijs van de producten of van dat gedeelte
aangehouden. waarop de vordering betrekking heeft, overtreffen. PPG zal
nimmer aansprakelijk zijn voor bedrijfsschade of enige
andere gevolgschade.
Garantie en aansprakelijkheid
PPG garandeert dat haar producten geen Het is PPG’s beleid om de producten continu te verbeteren
materiaalgebreken vertonen en vakkundig zijn vervaardigd. met als gevolg dat de inhoud van deze
PPG’s enige verplichting en kopers enige aanspraak met productinformatie/applicatie-instructie zonder kennisgeving
betrekking tot de producten zullen naar keuze van PPG kan wijzigen.
beperkt zijn tot hetzij vervanging van de producten Het is de verantwoordelijkheid van de koper om zich er van
voorzover deze niet in overeenstemming met de garantie te verzekeren dat de actuele versie wordt gebruikt. Voor de
blijken te zijn, hetzij tot creditering van kopers rekening met actuele versie van de product data/applicatie-instructies
het factuurbedrag van de producten die niet aan de garantie verwijzen wij naar de
voldoen. Iedere vordering die op deze garantie is PPG Protective & Marine Coatings website:
gebaseerd, dient koper schriftelijk bij PPG in te dienen, en www.ppgpmc.com.
wel uiterlijk binnen vijf (5) dagen nadat de gepretendeerde
tekortkoming is ontdekt, maar in ieder geval binnen de Om verwarring te voorkomen die kan ontstaan door de
toepasselijke bewaartijd, of binnen 1 ja na de vertaling in andere talen, is de Engelse versie van de
leveringsdatum als deze korter is. Blijft koper in gebreke om Productinformatie/applicatie-instructies doorslaggevend. Bij
bij PPG aldus vorderingen in te dienen, dan vervalt iedere afwijkingen ten opzichte van de productinformatie in andere
aanspraak op garantie. talen geldt de Engelse versie.
Productinformatie/
Applicatie-instructies Technische gegevens
Uiterlijk ................................... mat
• Hoog metallic zinkgehalte in de droge laag Kleur ...................................... roodachtig grijs
• Koppelt de taaiheid van epoxy aan de
Componenten ........................ 2
uitstekende beschermende eigenschappen van
zink Mengverhouding (volume)
• Uitstekende bestendigheid tegen de inwerking hars ...................................... 4 delen
verharder ............................. 1 deel
van weer en wind
• Uitstekende resultaten in zowel maritieme als Doorharding ........................... door verdampen van de
industriële omgevingen oplosmiddelen en reactie tussen de
componenten
• Kan eenvoudig met airless of conventionele
spuitapparatuur worden opgebracht Vaste-stofgehalte .................. 62% (ISO 3233)*
VOC**
Algemene toepassingen in combinatie met EC SED 1999/13/EC ........... 139 g/kg (363 g/l)
geschikt deklaag systeem kan Amercoat 68G worden UK PG6/23(92) Appendix 3 . 300 g/l (2.5 lbs/gal)
gebruikt in de volgende toepassingen:
INDUSTRIEEL - Staalconstructies, machines, buizen Droge-laagdikte ..................... 75 µm (3 duizendste inch) per laag
en de buitenkant van tanks in papierfabrieken, Aantal lagen .......................... 1
olieraffinaderijen, krachtcentrales, chemische
fabrieken en zuiveringsinstallaties. Theoretisch rendement ......... 8,3 m²/l (bij 75 µm)
2
338 ft /gal (bij 3 duizendste inch)
SCHEEPVAART - Dekken, rompen en bovenbouw
van schepen, aken en werkeilanden. Op pieren, Exclusief applicatieverliezen, onregelmatigheden van de
offshore-platforms en aanverwante constructies. ondergrond etc.
ISO 12944 Amercoat 68G Amercoat 383H Amercoat Applicatiemethode.................. airless of conventionele
C5 m/i hoog Amerlock-serie 450-serie spuitapparatuur, kwast of roller
Applicatiemethode
Amercoat 68G is verpakt in de juiste mengverhouding in Verzendgegevens
twee componenten (hars en verharder).
Verpakking
Hars: 8 l (2,1 gal) in 10 l blik
hars ................................ 8 l (2,1 gal) in 10 l blik
Verharder: 2 l (0,53 gal) in 2½ l blik
verharder ........................ 2 l (0,53 gal) in 2½ l blik
1. Spoel de apparatuur vóór gebruik met Amercoat 9HF. Verzendgewicht
2. Roer de hars (in de grotere container) met een hars ................................ ca. 26 kg
mechanische menger tot een gelijkmatige consistentie is verharder ........................ ca. 1,9 kg
verkregen.
3. Voeg verharder aan de harsoplossing toe en blijf 5 Houdbaarheid ................... 1 jaar vanaf verzenddatum,
minuten lang roeren. Zeef het materiaal met een 250 µm mits binnen opgeslagen in
(60 mesh) zeef om eventuele verstopping van de ongeopende, originele
apparatuur te voorkomen. OPMERKING: Omdat de verpakking bij 5 tot 40°C (41 tot
verwerkingstijd beperkt is en door hoge temperaturen 104°F)
wordt verkort, dient slechts zoveel materiaal te worden
gemengd als binnen 8 uur bij 20°C (68°F) kan worden
opgebracht.
4. Verdunning is doorgaans niet noodzakelijk bij airless
spuiten. Bij toepassing van conventionele
spuitapparatuur is verdunning alleen toegestaan om de
verwerkbaarheid van het materiaal te verbeteren; hierbij
mag niet meer dan 10 vol-% Amercoat 9HF worden
toegevoegd.
5. Tijdens het opbrengen van het product roeren om het
materiaal homogeen te houden. Breng een natte laag
aan in regelmatige, evenwijdige banen. Overlap elke
vorige baan met 50%, om niet geraakte plaatsen,
pinholes of heilige dagen te voorkomen.
6. Breng op alle lasnaden, ruwe plekken, scherpe randen
en hoeken, klinknagels, bouten etc. een dubbele
laagdikte aan.
7. Een natte-laagdikte van 120 µm (4,8 duizendste inch)
zal doorgaans resulteren in een droge-laagdikte van 75
µm (3 duizendste inch). Voorkom overapplicatie, dit kan
resulteren in verminderde cohesieve kracht wanneer
deze wordt overschilderd.
8. Controleer de droge-laagdikte met een niet-destructieve
droge-laagdiktemeter, zoals Mikrotest of Elcometer.
Breng extra materiaal aan indien de dikte minder is dan
voorgeschreven.
9. Kleine beschadigde of niet geraakte plaatsen en hier en
daar voorkomende pinholes of heilige dagen kunnen
met de kwast worden bijgewerkt. Werk grotere
oppervlakken met de spuit bij.
10. Tijdens applicatie en droging dient in afgesloten ruimten
met verse lucht te worden geventileerd, totdat alle
oplosmiddelen zijn verdwenen. De temperatuur en
vochtigheid van de verse lucht dienen zodanig te zijn,
dat zich op het oppervlak geen condens kan vormen.
11. Reinig alle apparatuur met Amercoat 9HF, onmiddellijk
na gebruik of uiterlijk aan het eind van iedere werkdag
of werktijd. Wanneer restanten van Amercoat 86G in de
spuitapparatuur achterblijven, zullen deze uitharden en
verstopping veroorzaken.
Productinformatie/
Applicatie-instructies
• Te gebruiken als lasbare constructieprimer of field Technische gegevens
of shop primer
• Door de snelle droogtijd kan vrijwel onmiddellijk Uiterlijk ................................... mat
met het bewerken, lassen, snijden en produceren
worden begonnen Kleur ...................................... oxiderood en grijs
• Kan van uiteenlopende deklagen worden voorzien Componenten ........................ 2
• Eenvoudig met automatische spuitapparatuur op te
brengen Mengverhouding (volume)
hars ..................................... 1 deel
• Simpele mengverhouding 1:1 verharder ............................ 1 deel
• Chromaat- en loodvrij
• In de UK overeenkomstig met EPA als straal primer Doorharding ........................... verdampen van de oplosmiddelen
en reactie tussen de componenten
staal.
- Bij een droge-laagdikte van 20 tot 25 µm biedt Amercoat Exclusief applicatieverliezen, onregelmatigheden van de
139 in gematigde industriële omgevingen een ondergrond etc.
bescherming gedurende maximaal 6 maanden.
- Kan worden aangebracht met airless of conventionele Soortelijk gewicht (gemengd product) 1.13 kg/l
spuitapparatuur, zowel automatisch als handmatig. Vlampunten (gesloten cup) .... ºC ºF
- Is geschikt voor automatisch of handmatig lassen en Amercoat 139 ..................... 3 39
snijden van stalen platen en profielen. Amercoat 18 ....................... 25 77
Amercoat 12 ....................... 24 75
Applicatiegegevens
Goedkeuringen en Certificaten
Getest en goedgekeurd als constructieprimer volgens de eisen van Ondergrond ........................... gestraald staal
Lloyd’s Register voor gebruik aan boord van schepen.
Tests door Newcastle Occupational Health Agency hebben uitgewezen Applicatiemethoden ............... airless of conventionele
dat het elektrisch lassen of het snijbranden van staalplaten die van een spuitapparatuur
laag Amercoat 139 primer zijn voorzien, geen nadelige gevolgen voor
de gezondheid heeft. Weersomstandigheden
Amercoat 139 is goedgekeurd door het Russian Maritime Register of (Tijdens aanbrengen en drogen)
Shipping. Luchttemperatuur:................ 5 tot 50°C 41 tot 122°F
Lasinspectierapporten worden op verzoek toegestuurd. Temp. ondergrond: .............. 5 tot 60°C 41 tot 140°F
Verzendgegevens
Applicatiemethode
Amercoat 139 is verpakt in de juiste mengverhouding in Verpakking
twee componenten (hars en verharder). hars ................................ 10 l in 20 l blik
Hars: 10 l in 10 l blik verharder ........................ 10 l in 10 l blik
Verharder: 10 l in 10 l blik
Verzendgewicht
1. Spoel de apparatuur met de aanbevolen reiniger.
hars ................................ ca. 15 kg
2. Roer elke component vóór de vermenging met een
verharder ........................ ca. 10 kg
krachtig menger tot een gelijkmatige consistentie is
verkregen. Houdbaarheid
3. Meng de verharder met de harsoplossing en blijf 5 hars/verharder ................ 1 jaar vanaf productiedatum,
minuten lang roeren. OPMERKING: Omdat de mits binnen opgeslagen in
verwerkingstijd door hoge temperaturen wordt verkort, ongeopende, originele
dient slechts zoveel materiaal te worden gemengd als verpakking bij 5 tot 40°C (41 tot
binnen de aangegeven verwerkingstijd kan worden 104°F).
opgebracht.
4. Bij toepassing van conventionele spuitapparatuur is
verdunning alleen toegestaan om de verwerkbaarheid
van het materiaal te verbeteren; hierbij mag niet meer
dan 10% van de aanbevolen verdunner worden
toegevoegd.
5. Tijdens het opbrengen van het product roeren om het
materiaal homogeen te houden. Breng een natte laag
aan in regelmatige, evenwijdige banen. Overlap elke
vorige baan met 50%, om niet geraakte plaatsen,
pinholes of heilige dagen te voorkomen.
6. Besteed speciale aandacht aan lasnaden, ruwe plekken,
scherpe randen en hoeken, klinknagels, bouten etc.
7. Applicatie van een natte-laagdikte van 80 µm zal
doorgaans resulteren in een droge-laagdikte van 20 µm.
8. Controleer de droge-laagdikte met een niet-destructieve
droge-laagdiktemeter, zoals Mikrotest of Elcometer.
Breng extra materiaal aan indien de dikte minder is dan
voorgeschreven. Bij automatisch spuiten moet gebruik
worden gemaakt van glasplaten en een
oppervlaktemicrometer, om de droge-laagdikte te
controleren en de apparatuur op de vereiste droge-
laagdikte aan te passen.
9. Kleine beschadigde of niet geraakte plaatsen en hier en
daar voorkomende pinholes of heilige dagen kunnen
met de kwast worden bijgewerkt. Werk grotere
oppervlakken met de spuit bij.
10. Tijdens applicatie en droging dient in afgesloten ruimten
met verse lucht te worden geventileerd, totdat alle
oplosmiddelen zijn verdwenen. De temperatuur en
relatieve vochtigheid van de verse lucht dienen zodanig
te zijn, dat zich op het oppervlak geen condens kan
vormen.
11. Reinig alle apparatuur met aanbevolen reiniger
onmiddellijk na gebruik of uiterlijk aan het eind van
iedere werkdag of werktijd. Wanneer restanten van het
product in de spuitapparatuur achterblijven, zullen deze
uitharden en verstopping veroorzaken.
Product Data/
Application Instructions Physical Data
Finish ..................................... low sheen
• Rapid drying two pack epoxy zinc phosphate Colour .................................... red oxide, light grey, grey, buff and
primer off white.
• EPA compliant (1998) in accordance with Components .......................... 2
PG6/23
• High build, high solids and low VOC Mixing ratio (by volume)
resin .................................... 6.2 parts
• Corrosion inhibiting cure ..................................... 1 part
• Excellent adhesion to blast cleaned steel
• Excellent abrasion and impact resistance Curing mechanism ................ solvent release and reaction
between components. Effective
• No maximum overcoating restrictions cure down to 5°C/41ºF
Flash points
(Closed Cup)........................ ºC ºF
resin .................................... 24 75
cure ..................................... 24 75
Amercoat 18 ....................... 25 77
Amercoat 12 cleaner............ 24 75
Surface preparation
Surfaces must firstly be thoroughly cleaned of all Application Data
contaminants such as dust, dirt, oil, grease and salts. Substrate ............................... blasted steel
Then abrasive blast clean to ISO 8501-1, Sa21/2. The
blast profile achieved should be within the range 50 to Application methods .............. airless spray, brush or roller
100 microns. Priming should occur before Potlife (at 20°C/68ºF) ............ 2 hours
degradation of the surface takes place. If oxidation
occurs then the surface should be re-prepared. The Induction time (at 20°C/68ºF) not applicable
surface must be dry and free of dust, salts, grease Environmental conditions
and other contaminants immediately before coating.
Steelguard 3290 should only be applied within the limits of
temperature and humidity set out below.
Mixing Relative humidity: ................ Up to 90%
Surface temperature: ........... Minimum 2°C/36ºF
Stir the resin component thoroughly, then add the ............................................. Maximum 40°C/104ºF
cure and continue mixing until the product is uniform
throughout. A powerful mixer should be used. The surface temperature must also be at least 3°C/5ºF above the
dew point during application.
As with most coatings early contact with water can result in water
Application spotting damage. Care should be taken to protect the coating
AIRLESS SPRAY: Use standard airless spray during the early stages of cure to prevent water marking.
equipment capable of producing a minimum pressure
at the tip of 2800 psi (200 kg/cm²). Tip size range 15- Drying characteristics ºC/ºF
21 thou (0.38-0.53mm). Adjustments to pressure and Temperature 5/41 10/50 20/68
tip size/angle may be necessary to obtain spray
characteristics required for specific substrate Touch dry 4 hours 2 hours 1 hours
configurations.
BRUSH/ROLLER: Application by these methods Hard dry 8 hours 5 hours
1
2 /2 hours
should be limited to small areas only such as repairs
and when stripe coating. Apply evenly using a clean, Overcoating 1
8 hours 5 hours 2 /2 hours
(minimum)
well-loaded brush or roller. With this application more
Overcoating - - -
than one coat may be necessary to achieve the (maximum)
required dry film thickness
This product will cure down to 0°C/32ºF, however drying
times will be extended.
Application procedure
1. Clean the equipment with the recommended cleaning Shipping Data
solvent before use.
Packaging............................... 20 litres in two part units
2. Stir the resin component thoroughly, then add the cure resin .................................... 17.23 l in 20 l can
and continue mixing until the product is uniform cure ..................................... 2.77 l in 5 l can
throughout. A powerful mixer should be used. Thinning
is not required. Shipping weight (approx)
3. For airless spray, apply a wet even coat in parallel resin .................................... . 31 kg
passes. Overlap each pass by 50% to avoid bare areas, cure ..................................... 4 kg
pinholes or holidays. Shelf life ................................. 1 year from shipment date or as
4. Give special attention to welds, rough spots, sharp indicated on label when stored
edges and corners, rivets, bolts, etc. indoors in unopened, original
5. Application at 104µm wet film thickness will normally containers at 5 to 40°C (41 to
provide 75µm dry film. 104ºF).
6. Check thickness of dry coating with a non-destructive
dry film thickness gauge, such as Mikrotest or
Elcometer. If less than specified thickness, apply
additional material as needed.
7. Small damaged or bare areas and random pinholes or
holidays can be touched up by brush. Repair larger
areas either by spray, brush or roller using Steelguard
3290.
8. In confined areas ventilate with clean air during
application and drying. The humidity should be
maintained below 90% and the temperature such that
moisture condensation will not form on the surface.
9. Clean all equipment with fresh, clean solvent
immediately after use.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Deklagen
Amercoat 220G
Amercoat 220 LS
Amercoat 450E
Amercoat 2136
Steelguard 2458
Amercoat 4310
PSX 700
> START
We Know...
Fire Protection
Coatings
Amercoat
Amercoat 220G
Acryl-finish op waterbasis
Productinformatie/
Applicatie-instructies Technische gegevens
Uiterlijk wanneer droog ...... glanzend
• Eéncomponenten-acryl-finish op waterbasis Kleur ................................... RAL en BS*
• Voldoet aan de EPA-voorschriften (1998)
• Laag gehalte aan vluchtige organische Componenten...................... 1
verbindingen Vaste-stofgehalte ............... 40 ± 2%
• Geurarm
• Onbrandbaar VOC**
EC SED 1999/13/EC......... 41 g/kg (50 g/l)
• Goed kleur- en glansbehoud UK PG6/23(92) Appendix 3 140 g/l
• Volkomen geschikt voor de meeste verouderde
coatings Doorharding......................... fysische droging
• Snel en eenvoudig aan te brengen met borstel, typisch minimaal maximaal
roller of spuitapparatuur
Droge-laagdikte (µm) 40 30 55
Applicatiemethoden Droogeigenschappen
AIRLESS SPUITEN – Spuitopening tussen 15 en 19
inch (0,38 - 0,48 mm). Druk aan de spuitmond 2800 Temperatuur ºC/ºF 10/50 20/68 30/86
psi (200 kg/cm²).
KWAST – Gelijkmatig opbrengen met een schone, Stofdroog 90 45 20
minuten minuten minuten
goed in het product gedompelde kwast. Let erop dat u
de coating niet te dun uitstrijkt. Doorgedroogd 4 uur 2 uur 1 uur
ROLLER - Gelijkmatig opbrengen met een schone,
goed in het product gedompelde roller. Let erop dat u Overschilder-baar 4 uur 2 uur 1 uur
de coating niet te dun uitrolt. Verwijder alle (minimaal)
luchtbelletjes met een kwast met stevig haar. Overschilder-baar Indien er met hetzelfde product
(maximaal) wordt overgeschilderd, geldt er
geen maximale tijd tot aan het
Overschilderbaar overschilderen
Kan, om een grotere laagdikte te verkrijgen, met
OPMERKING : De droog- en uithardingstijden zijn afhankelijk van
hetzelfde product worden overgeschilderd. Bij de lucht- en ondergrondtemperaturen, de aangebrachte laagdikte,
bepaalde sterke kleuren kunnen er meer dan één de ventilatie en andere omgevingscondities. Deze tijden zijn korter
laag nodig zijn, om de volle opaciteit te verkrijgen. bij hogere temperaturen en langer bij lagere temperaturen.
Applicatiemethode
1. Spoel de apparatuur vóór gebruik met de Verzendgegevens
aanbevolen reiniger. Verpakkingsgrootte ...... 5 liter
2. Roer de inhoud van de bus, tot een gelijkmatige
consistentie is verkregen. Verzendgewicht ............ ca. 7 kg
3. Verdunning is doorgaans niet noodzakelijk bij
airless spuiten. Houdbaarheid .............. 1 jaar vanaf verzenddatum
4. Tijdens het opbrengen van het product roeren om of zoals aangegeven op het
het materiaal homogeen te houden. Bij spuiten etiket, mits binnen
een natte laag in regelmatige, evenwijdige banen opgeslagen in ongeopende,
aanbrengen. Overlap elke vorige baan met 50%, originele verpakking bij 5 tot
om niet geraakte plaatsen, pinholes of heilige 40°C (41 tot 104ºF)
dagen te voorkomen.
5. Breng op alle ruwe plekken, scherpe randen en
hoeken, klinknagels, bouten etc. een dubbele
laagdikte aan.
6. Een natte-laagdikte van 100 µm zal doorgaans
resulteren in een droge-laagdikte van 40 µm.
7. Controleer de droge-laagdikte met een niet-
destructieve droge-laagdiktemeter, zoals Mikrotest
of Elcometer. Breng extra materiaal aan indien de
dikte minder is dan voorgeschreven.
8. Kleine beschadigde of niet geraakte plaatsen en
hier en daar voorkomende pinholes of heilige
dagen kunnen met de kwast worden bijgewerkt.
Werk grotere oppervlakken met de spuit bij.
9. Tijdens applicatie en droging dient in afgesloten
ruimten met verse lucht te worden geventileerd,
totdat alle oplosmiddelen zijn verdwenen. De
temperatuur en relatieve vochtigheid van de verse
lucht dienen zodanig te zijn, dat zich op het
oppervlak geen condens kan vormen.
10.Reinig alle apparatuur met aanbevolen reiniger
onmiddellijk na gebruik of uiterlijk aan het eind van
iedere werkdag of werktijd.
Verkoopvoorwaarden
Op al onze transacties zijn onze verkoopvoorwaarden
van toepassing
Applicatie-apparatuur
Droogtijden zoals vermeld onder Omgevingscondities
De volgende opsomming van apparatuur dient als leidraad.
Vergelijkbare apparatuur van andere leveranciers mag worden Droogtijden (°C/°F) 49/120 32/90 21/70 10/50
gebruikt. Om het juiste spuitpatroon te verkrijgen, moeten Stofdroog ............................. NR 15 min. 15 min. 45 min.
eventueel de druk en de spuitopening aangepast worden. Doorgedroogd...................... NR 15 min. 30 min. 2 uur
AIRLESS SPUITEN - Normale airless spuitapparatuur, zoals Tijden tot aan het
Graco, DeVilbiss, Nordson-Bede, Speed-Flo, of andere overschilderen (°C/°F) 49/120 32/90 21/70 10/50
fabrikaten met een spuitopening van 0,28 tot 0,43 mm (0,011 Minimale tijden (uur) ............ NR 0,5 2 6
tot 0,017 inch).
CONVENTIONEEL SPUITEN - Industriële apparatuur, zoals Verdunner............................... Water
het spuitpistool van het fabrikaat DeVilbiss MBC of JGA met Reiniger voor gereedschap .... Water of water met een
luchtkap 75 of 765, "E" tip en zware mastiekveer, of Binks nr. reinigingsmiddel
18 of 62 met 66 x 63 PB spuitopening. Afzonderlijke
drukregelaars voor lucht en vloeistof en een drukvat met
roerwerk worden aanbevolen. Er moet een water- en olie-
afscheider in de hoofdluchttoevoerleiding worden aangebracht.
Applicatiemethode Verzendgegevens
Amercoat 220 LS is verpakt in hoeveelheden van 5 l in 5 l
blikken. Verpakking ........................ 5 l in 5 l blik
1. Reinig de apparatuur vóór gebruik met een geschikt
Verzendgewicht kg lb
oplosmiddel en spoel deze vervolgens goed met schoon
........................................ ca. 5 11
water.
2. Roer het product goed door met een mechanische Houdbaarheid.................... 1 jaar vanaf verzenddatum,
menger totdat een gelijkmatige, verwerkbare mits binnen opgeslagen in
consistentie wordt verkregen. ongeopende, originele
3. Hoewel het product dikvloeibaar is, is verdunnen verpakking bij 5 tot 40°C (41 tot
doorgaans niet nodig voor toepassing in 104°F).**
spuitapparatuur. Verdun alleen voorzover nodig om een
goede verwerkbaarheid te verkrijgen en gebruik niet
meer dan 10 vol.% verdunner Gebruik alleen schoon ** Omdat het product water bevat, moet het tegen
zoetwater voor het verdunnen. bevriezing worden
4. Tijdens het opbrengen van het product roeren om het beschermd
materiaal homogeen te houden. Breng een natte laag
aan in regelmatige, evenwijdige banen. Overlap elke
vorige baan met 50%, om niet geraakte plaatsen,
pinholes of heilige dagen te voorkomen.
5. Breng op alle lasnaden, ruwe plekken, scherpe randen
en hoeken, klinknagels, bouten etc. een dubbele
laagdikte aan.
6. Een natte-laagdikte van 120 µm zal doorgaans
resulteren in een droge-laagdikte van 50 µm.
7. Controleer de droge-laagdikte met een niet-destructieve
droge-laagdiktemeter, zoals Mikrotest of Elcometer.
Breng extra materiaal aan indien de dikte minder is dan
voorgeschreven.
8. Kleine beschadigde of niet geraakte plaatsen en hier en
daar voorkomende pinholes of heilige dagen kunnen
met de kwast worden bijgewerkt. Werk grotere
oppervlakken met de spuit bij.
9. Tijdens applicatie en droging dient in afgesloten ruimten
met schone lucht te worden geventileerd, totdat de
ondergrond geheel droog is. De temperatuur en
relatieve vochtigheid van de verse lucht dienen zodanig
te zijn, dat zich op het oppervlak geen condens kan
vormen.
10. Reinig alle apparatuur met zoet water of water met een
reinigingsmiddel onmiddellijk na gebruik of uiterlijk aan
het eind van iedere werkdag of werktijd. Wanneer
restanten van Amercoat 220 LS in de spuitapparatuur
achterblijven, kunnen deze verstopping veroorzaken.
Reparatie
Kale ondergrond plaatselijk aanstralen of mechanisch
reinigen conform de eisen die onder “Voorbehandeling van
de ondergrond” zijn vermeld en met het originele
coatingmateriaal gronden. Overlapgebieden licht
aanstralen. Verwijder stof, vuil en verontreinigingen vóór het
overschilderen
Verkoopvoorwaarden
Op al onze transacties zijn onze verkoopvoorwaarden
van toepassing
PPG Industries Netherlands BV
Tel +(31) 345 587 200
www.ppgpmc.com
Ameron Coatings has become part of PPG Industries
Pagina 4 v/d 4 Revisiedatum:20-03-2008
Amercoat
Amercoat 450E
Alifatische polyurethaandeklaag (450-serie)
Reparatie
Voor reparatiedoeleinden of voor het verkrijgen van
een extra laagdikte kan Amercoat 450E onbeperkt
met hetzelfde product worden overgeschilderd. Zorg
ervoor dat het oppervlak schoon is, alvorens het
product op te brengen.
Productinformatie/
Applicatie-instructies Technische gegevens
Uiterlijk wanneer droog........... zwak glanzend, metallic glans
• Functionele éénlaags- high-build deklaag. Kleur ...................................... zwart, middelgrijs, zilvergrijs, licht
• Direct aan te brengen op gegalvaniseerd staal zilver
• Uitgebreide staat van dienst Componenten......................... 1
• Eéncomponent-materiaal
• Volkomen geschikt voor de meeste verouderde Doorharding............................ Verdampen van oplosmiddelen
coatings Vaste-stofgehalte .................. 53±2%
• Geen spanning door overschilderen
VOC*
EC SED 1999/13/EC ........... 304 g/kg (484 g/l)
Typische toepassingen UK PG6/23(92) Appendix 3 . 490 g/l
Amercoat 2136 is een met ijzerglimmer Laagdikte typisch minimaal maximaal
gepigmenteerde high-build coating die speciaal is Droge-laagdikte (µm/mils).... 75/3 65/2,6 100/4
ontwikkeld om zowel stalen als gegalvaniseerd stalen Natte-laagdikte (µm/mils) .... 142/5,7 142/5,7 189/7,6
constructies te beschermen, waaronder de bovenkant (de opgegeven natte-laagdiktes zijn theoretische waarden voor een
van tanks/het uitwendige van omhullingen, kwast-laag)
hekwerken, gegalvaniseerde leidingen/ bekleding,
Theoretisch rendement ......... 7,1 m²/l (typische droge-laagdikte)
straatmeubilair en lichtmasten. 2
289 ft /gal
Mengen
Voor gebruik goed mengen, totdat het product een
volledig gelijkmatige consistentie heeft.
Applicatie-apparatuur
De volgende opsomming van apparatuur dient als leidraad.
Vergelijkbare apparatuur van andere leveranciers mag
worden gebruikt. Om het juiste spuitpatroon te verkrijgen,
moeten eventueel drukken aangepast en spuitopeningen
gewijzigd worden.
KWAST/ROLLER - Gelijkmatig opbrengen met een schone,
goed in het product gedompelde kwast of roller. De natte
laag niet proberen "uit te strijken" of laten "vervloeien".
AIRLESS SPUITEN – Mag worden verdund met maximaal
10 vol.% van de aanbevolen verdunner. Spuitopening
tussen 0,015 en 0,018 inch (0,38 - 0,46 mm).
2
Druk spuitmond: 2800 psi (200 kg/cm ).
Applicatie procedure
1. Spoel de apparatuur vóór gebruik met de Verzendgegevens
aanbevolen reiniger. Verpakkingsgrootte....... 5 liter (1,32 gal)
2. Roer de inhoud van het blik met een mechanische
menger tot een gelijkmatige consistentie is Verzendgewicht ............ ± 8.5 kg
verkregen.
3. Indien nodig verdunnen met maximaal 10 vol.% Houdbaarheid 1 jaar, mits binnen
van de aanbevolen verdunner. opgeslagen in ongeopende,
4. Tijdens het opbrengen van het product roeren om originele verpakking bij 5 tot
het materiaal homogeen te houden. Breng een 35°C.
natte gelijkmatige laag aan in regelmatige,
evenwijdige banen. Overlap elke vorige baan met
50%, om niet geraakte plaatsen, pinholes of
heilige dagen te voorkomen.
5. Breng op alle lasnaden, ruwe plekken, scherpe
randen en hoeken, klinknagels, bouten etc. een
dubbele laagdikte aan.
6. Een natte-laagdikte van 142 µm zal doorgaans
resulteren in een droge-laagdikte van 75 µm.
7. Controleer de droge-laagdikte met een niet-
destructieve droge-laagdiktemeter, zoals Mikrotest
of Elcometer. Breng extra materiaal aan indien de
dikte minder is dan voorgeschreven.
8. Kleine beschadigde of niet geraakte plaatsen en
hier en daar voorkomende pinholes of heilige
dagen kunnen met de kwast worden bijgewerkt.
Werk grotere oppervlakken met de spuit of kwast
bij.
9. Tijdens applicatie en droging dient in afgesloten
ruimten met verse lucht te worden geventileerd,
totdat alle oplosmiddelen zijn verdwenen. De
temperatuur en relatieve vochtigheid van de verse
lucht dienen zodanig te zijn, dat zich op het
oppervlak geen condens kan vormen.
10.Reinig alle apparatuur met water onmiddellijk na
gebruik of uiterlijk aan het eind van iedere
werkdag of werktijd.
Verkoopvoorwaarden
Op al onze transacties zijn onze verkoopvoorwaarden
van toepassing
Productinformatie/
Applicatie-instructies Technische gegevens
Uiterlijk na droging.................. halfmat
• Conform EPA (1998) als een deklaag voor Kleur ...................................... RAL- en BS-kleuren*
brandwerende Steelguard-coatings
Componenten......................... 1
• High-build
• Geschikt voor blootstelling aan buitenlucht en Hardingsmethode ................... verdamping van oplosmiddelen
weersinvloeden
Vaste-stofgehalte .................. 45 ± 2%
• Eéncomponent-materiaal
• Goed kleurbehoud VOC**
EC SED 1999/13/EC ........... 430 g/kg (532 g/l)
UK PG6/23(92) Appendix 3 . 499 g/l
Typische toepassingen
Laagdikte (µm) typisch minimaal maximaal
In werkplaats of op locatie aan te brengen Droge-laagdikte ................. 75 50 125
beschermende deklaag voor brandwerende Natte-laagdikte ................... 167 111 278
Steelguard-coatings.
(De opgegeven natte-laagdiktes zijn theoretische waarden voor
één airless opgebrachte spuitlaag)
Vlampunt
(gesloten cup) ...................... ºC ºF
Steelguard 2458 .................. 24 75
Amercoat 65 ........................ 24 75
Applicatiemethode:
1. Spoel de apparatuur vóór gebruik met de Verzendgegevens
aanbevolen reiniger. Grootte van de verpakking 20 liter
2. Roer het product met een mechanische menger
tot een gelijkmatige consistentie is verkregen. Verzendgewicht ................ ca. 28 kg
3. Verdunning is doorgaans niet noodzakelijk bij
Houdbaarheid ................... 1 jaar, mits binnen opgeslagen
airless spuiten. in ongeopende, originele
4. Roeren tijdens gebruik om het materiaal verpakking bij 5 tot 40 °C (41
homogeen te houden. tot 104 °F)
Breng een natte gelijkmatige laag aan in
regelmatige, evenwijdige banen. Overlap elke
vorige baan met 50%, om niet geraakte plaatsen,
pinholes of heilige dagen te voorkomen.
5. Breng op alle ruwe plekken, scherpe randen en
hoeken, klinknagels, bouten etc. een dubbele
laagdikte aan.
6. Een natte-laagdikte van 167 µm zal doorgaans
resulteren in een droge-laagdikte van 75 µm.
7. Controleer de droge-laagdikte met een niet-
destructieve droge-laagdiktemeter, zoals Mikrotest
of Elcometer. Breng extra materiaal aan indien de
dikte minder is dan voorgeschreven.
8. Kleine beschadigde of niet geraakte plaatsen en
hier en daar voorkomende pinholes of heilige
dagen kunnen met de kwast worden bijgewerkt.
Werk grotere oppervlakken met de spuit bij.
9. In afgesloten ruimten dient tijdens
applicatie en droging met schone lucht te worden
geventileerd totdat alle oplosmiddelen uit de
ruimte verdwenen zijn. De temperatuur en
vochtigheid van de verse lucht dienen zodanig te
zijn, dat zich op het oppervlak geen condens kan
vormen.
10.Reinig alle apparatuur met aanbevolen reiniger
onmiddellijk na gebruik of uiterlijk aan het eind van
iedere werkdag of werktijd.
Verkoopvoorwaarden
Op al onze transacties zijn onze verkoopvoorwaarden
van toepassing
Mixing
Stir thoroughly before use until the product is uniform
throughout.
Application Methods
AIRLESS SPRAY: Use standard airless spray Application Data
equipment capable of producing a minimum pressure Substrate ................................ Primed substrates
at the tip of 2800 psi (200 kg/cm²). Tip size range 13-
17 thou (0.33-0.43mm). Adjustments to pressure and Application methods ............... airless or conventional spray, brush
or roller
tip size/angle may be necessary to obtain spray
characteristics required for specific substrate Potlife (at 20°C/68ºF) ............ N/A
configurations.
Environmental Conditions
CONVENTIONAL SPRAY: Use standard industrial Amercoat 4310 should only be applied within the limits of
equipment. Thinning with the recommended thinner temperature and humidity set out below.
may be necessary to facilitate application. Relative humidity: ................ up to 90%
BRUSH/ROLLER: Apply evenly using a clean, well- Surface temperature: ........... minimum: 5°C/41ºF
............................................. maximum: 40°C/104ºF
loaded brush or roller. With this application more than
one coat may be necessary to achieve the required dry The surface temperature must also be at least 3°C/5ºF above dew
film thickness. point.
NOTE: drying and curing times are dependent on air and steel
temperature, applied film thickness, ventilation and other
environmental conditions. Times are shorter at higher temperatures
and longer at lower temperatures
Application procedure
1. Flush equipment with recommended cleaner Shipping Data
before use. Pack size ............................... 5 litres
2. Stir the contents of the can to an even
consistency. Shipping weight ...................... approx. 6 kg
3. Thinning is normally not required for airless spray. Shelf life ................................. 1 year from shipment date or as
4. Stir during application to maintain uniformity of indicated on label when stored
material. Apply a wet even coat in parallel passes. indoors in unopened, original
containers at 5 to 40°C (41 to
Overlap each pass 50% to avoid bare areas, 104ºF).
pinholes or holidays.
5. Double coat all rough spots, sharp edges and
corners, rivets, bolts, etc.
6. Application at 85 µm wet film thickness will
normally provide 40 µm dry film.
7. Check thickness of dry coating with a non-
destructive dry film thickness gauge, such as
Mikrotest or Elcometer. If less than specified
thickness, apply additional material as needed.
8. Small damaged or bare areas and random
pinholes or holidays can be touched up by brush.
Repair larger areas by spray.
9. In confined areas ventilate with clean air during
application and drying until all solvents are
removed. Temperature and humidity of ventilating
air must be such that moisture condensation will
not form on surface.
10.Clean all equipment with recommended cleaner
immediately after use or at least at the end of each
working day or shift
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Applicatie-instructies
Technische gegevens
Uiterlijk ................................... glanzend
• Speciale hoogglans-siloxaancoating met unieke
eigenschappen Kleur ...................................... RAL- en BS-kleuren *
• Kan direct op anorganisch zink worden Componenten ........................ 2
aangebracht
• Het glansbehoud en de bestendigheid van het Mengverhouding (naar volume)
uiterlijk van PSX 700 overtreffen die van het beste PSX 700 hars ...................... 4 delen
PSX 700 FD verharder ....... 1 deel
polyurethaan
• Aanzienlijk lagere arbeidskosten Doorharding ........................... chemische reactie
• Uitstekende corrosiebestendigheid Volume vaste stof .................. 90% (ISO 3233)**
• Hoog vaste-stofgehalte, in overeenstemming met
VOC (vluchtige organische verbindingen) VOC***
• Aan te brengen met kwast, roller of EC SED 1999/13/EC ........... 88 g/kg (120 g/l)
UK PG6/23(92) Appendix 3 . 120 g/l (1.0 lbs/gal)
spuitapparatuur, zonder verdunning
Droge-laagdikte**** ............... 75-175 µm per laag
Reparatie
Bereid beschadigde oppervlakken voor zoals omschreven onder Verzendgegevens
“Voorbehandeling van de ondergrond” en rond scherpe kanten van
beschadigde plekken in voor de rest intacte coatings af. Stof of Verpakking
resten van het straalmiddel grondig verwijderen, alvorens het PSX 700 hars ...................... 16 l in een 20 l blik
oppervlak bij te werken. PSX 700 FD verharder ....... 4 l in een 5 l blik
Verzendgewicht
Applicatie-apparatuur PSX 700 hars ...................... ca. 25.5 kg
De volgende opsomming van apparatuur dient als leidraad. PSX 700 FD verharder ....... ca. 4.4 kg
Vergelijkbare apparatuur van andere leveranciers mag worden
gebruikt. Om het juiste spuitpatroon te verkrijgen, moeten Houdbaarheid......................... 1 jaar vanaf verzenddatum, mits
eventueel drukken, slangen en spuitopeningen gewijzigd worden. binnen opgeslagen in ongeopende,
AIRLESS SPUITAPPARATUUR - Normale apparatuur, en een originele verpakking bij 5 - 40°C
spuitopening van 015 tot 0.021(mm) of groter. (41-104ºF)
CONVENTIONEEL SPUITEN - Industriële apparatuur.
Afzonderlijke drukregelaars voor lucht en vloeistof en een drukvat
met roerwerk worden aanbevolen.
Uitharding in de oven
Zorg ervoor dat PSX 700 stofdroog is, alvorens het aan
uithardingstemperaturen van meer dan 60°C/140ºF bloot te stellen.
Applicatiemethode
1. Spoel de apparatuur met verdunner of Amercoat 12 vóór
gebruik.
2. Meng tot een gelijkmatige consistentie is verkregen.
3. Voeg PSX 700 FD verharder aan de PSX 700 hars toe. Roer
het geheel goed door, totdat een gelijkmatige consistentie is
verkregen.
4. Indien verdunning nodig is ter verbetering van de
verwerkbaarheid, mag maximaal 10 volume % aanbevolen
thinner worden toegevoegd.
5. Breng een natte laag in regelmatige, evenwijdige banen op;
overlap elke vorige baan met 50%, om heilige dagen, niet
geraakte plaatsen en pin holes te voorkomen. Spuit vervolgens
haaks op de eerste laag na, indien nodig.
6. Bij applicatie met een kwast en/of roller is meer dan 1 laag
nodig, om een droge-laagdikte van 175 µm te verkrijgen. Er zal
tot op zekere hoogte sprake zijn van een oppervlaktestructuur
die inherent is aan het opbrengen van materiaal met een kwast
en/of roller.
7. Indien PSX 700 direct op Dimetcote wordt aangebracht, kan
een nevellaag/volledige laag nodig zijn, om blaasjesvorming tot
een minimum te beperken. Verdun PSX 700 met maximaal 10
volume% aanbevolen thinner, om de laagdikte beter te kunnen
beheersen en blaasjesvorming tot een minimum te beperken.
Dit is afhankelijk van de ouderdom van de coating, de
oppervlakteruwheid en de omstandigheden gedurende het
uitharden.
8. Reinig alle apparatuur onmiddellijk na gebruik met verdunner of
reiniger Amercoat 12
Waarschuwing
Iedere aanbeveling of suggestie betreffende het gebruik
Houd het product uit de buurt van hitte en open vuur. Houd
van de door PPG vervaardigde producten, hetzij in haar
het blik gesloten. Zorg voor voldoende ventilatie. Vermijd
technische beschrijvingen, hetzij als antwoord op een
langdurig en herhaaldelijk contact met de huid. Neem bij
speciaal verzoek of anderszins, wordt gedaan op grond van
gebruik in gesloten ruimtes de volgende
gegevens die geacht kunnen worden betrouwbaar te zijn.
voorzorgsmaatregelen in acht, om brand, explosiegevaar of
Niettemin zijn de producten en de informatie bestemd voor
nadelige gevolgen voor de gezondheid te voorkomen:
gebruik door kopers die de vereiste vaardigheid en kennis
1. laat gedurende de applicatie en het drogen voortdurend
in de branche hebben. Daarom dient koper zichzelf te
voldoende verse lucht circuleren;
overtuigen van de geschiktheid van de producten voor het
2. gebruik verse-luchtmaskers en explosievrije apparatuur;
gebruik dat de koper beoogt. Koper wordt geacht dit
3. vermijd open vuur, vonken, lassen en roken.
volledig naar eigen inzicht en voor eigen risico te hebben
Laat geen materiaal in het riool weglopen. Neem
gedaan. Veranderingen in de omgeving, het klimaat en het
voorzorgsmaatregelen tegen statische ontladingen. Voor
milieu, of procedures bij de toepassing, alsook extrapolatie
specifieke informatie over gevaarlijke bestanddelen,
van gegevens, kunnen onbevredigende resultaten
vereiste ventilatie, mogelijke gevolgen bij contact of
veroorzaken.
blootstelling, en veiligheidsmaatregelen, zie de
veiligheidsvoorschriften.
Aansprakelijkheidsbeperking
De aansprakelijkheid van PPG voor welke vordering dan
Veiligheid
ook, waaronder begrepen vorderingen die hun oorzaak
Omdat verkeerd gebruik en verkeerde handeling van dit
vinden in nalatigheid of onachtzaamheid van PPG, voor
product nadelige gevolgen voor de gezondheid kan hebben
verlies of schade voortkomend uit, samenhangend met of
en bovendien kan leiden tot brand of explosies, dienen de
ten gevolge van het gebruik van de producten, kan in geen
bij de product data/applicatie-instructies en de bij het
geval de koopprijs van de producten of van dat gedeelte
veiligheidsinformatieblad gevoegde veiligheidsinstructies
waarop de vordering betrekking heeft, overtreffen. PPG zal
tijdens opslag, handeling, gebruik en drogen te worden
nimmer aansprakelijk zijn voor bedrijfsschade of enige
aangehouden.
andere gevolgschade.
Language Selection
French
We Know...
Fire Protection
Coatings
PROFESSIONALS IN PROTECTION
> START
We Know...
Fire Protection
Coatings
PROFESSIONALS IN PROTECTION
Steelguard CM 4701
Steelguard CM 4702
Steelguard CM 4703
Steelguard CM 4704
Steelguard CM 4705
Steelguard CM 4706
> START
We Know...
Fire Protection
Coatings
Amercoat
Steelguard CM 4701
Spray Applied Fire Resistant Tunnel Coating
Product Data/
Application Instructions Physical Data
Appearance ............................ sprayed textured finish, usually
trowelled to close the surface
• Passive fire protection for use in tunnels
• Spray applied Colour .................................... off white
• Durable, impact resistant Components ........................... 1 (excluding water/additives)
• Modified vermiculite cement
3
• Tested to meet recognized international tunnel Dry density of the powder....... 465 kg/m
standards 3
Nominal dry density applied ... 725-775 kg/m
• Most fire ratings achieved in one single application
• Top coat systems to meet required colour and VOC ....................................... 0 g/l
reflectance levels
Curing mechanism ................. Hydrolisation
• Easy clean top coats
• Up to 4 hours insulation Thickness requirements ......... Contact PPG for details
Approvals
Steelguard CM 4701 is tested to resist fire conditions
in tunnels meeting recognized international tunnel
standards including the RATB in Germany,
Eurocode’s 1, 2 & 3 (EN 1991-1-2; EN 1992-1-2 & EN
1993-1-2) and the Dutch Rijkswaterstaat in
cooperation with the TNO Institute using the ‘RWS
97-CVB-R0710 Hydrocarbon time/temperature curve.
Project specific tunnel fire test may be required.
For suitable tunnel system specification contact PPG
for details.
Application Equipment
Use a mechanical piston or rotor stator type pump equipped
with a high-pressure plaster type hose avoiding brass or
aluminium type couplings. The flexible hose length should not
exceed 100 meters, with following typical length.
I.D. 75 mm (3”) maximum 100 meters
I.D. 50 mm (2”) maximum 50 meters
I.D. 35 mm (1 ½ ”) maximum 15 meters
I.D. 30 mm (1 ¼ ”) maximum 8 meters
For longer lengths use metal pipe with a I.D. of 65 -75 mm
Use as spray nozzle assembly a minimally 25-32 mm nozzle
with a 10 to 13 mm nozzle orifice and a rubber blow-off cap.
Atomising air should be 2-4 bar (28-57 psi) at the nozzle.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance ............................ sprayed textured finish, usually
trowelled to close the surface
• Passive fire protection for use in refineries and tank
storage facilities, in industrial and chemical plants and Colour .................................... grey
on offshore platforms.
• Meets international hydrocarbon fire standards Components ........................... 1 (excluding water/additives)
• Spray applied Dry density of the powder....... 465 kg/m
3
levelling by trowel this can be achieved by spray application At the end of the spray line 1050 – 1200 kg/m
3
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance ............................ sprayed textured finish, usually
trowelled to close the surface
• Passive fire protection for steel framed structures
• Spray applied Colour .................................... light grey
• Durable, impact resistant Components ........................... 1
• Modified vermiculite cement
3
• Up to 4 hours fire protection of structural steel Nominal dry density ............... 725-775 kg/m
• Most fire ratings achieved in one single application VOC ....................................... 0 g/l
• Excellent weathering resistance meeting upto ISO
12944 C5M requirements. Curing mechanism ................. Hydrolisation
levelling by trowel this can be achieved by spray application At the end of the spray line 1050 – 1200 kg/m
3
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance ............................ sprayed textured finish, usually
trowelled to close the surface
• Passive fire protection for steel framed
structures Colour .................................... grey
• Spray applied Components ........................... 1
• Robust coating for internal C1/C2
3
environments (ISO 12944) Nominal dry density ............... 350-400 kg/m
• Modified vermiculite cement VOC ....................................... 0 g/l
• Up to 4 hours fire protection of structural steel
• Most fire ratings achieved in one single Curing mechanism ................. Hydrolisation
application Loading requirements: In order to establish the thickness required
to give the specified fire resistance, reference should be made to
the products Hp/A (A/V) values or limiting temperature tables.
Typical Uses Contact your PPG representative for full details.
Steelguard CM 4704 is a tough hard and highly stable
passive fire protection for use on internal structural steel. Nominal usage at 25 mm thickness
The spray-applied coating shows excellent mechanical Per 25 kg sack........................ 2.65 m
2
resistance. It does not rely on any form of expansion, Per tonne................................ 106 m
2
levelling by trowel this can be achieved by spray application At the end of the spray line 900 – 1050 kg/m
3
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance ............................ clear when dry
• Additive for modified Steelguard CM Colour .................................... milky white liquid
vermiculate cement coatings
Components ........................... 1
• Adhesion promoter in bonding coat
• Improves substrate adhesion Specific gravity ....................... 1.08 kg/l
• Improves cohesive strength
pH........................................... 4.5 – 5.5
• Improves early water resistance
Volume solids ......................... 50% ± 2%
Application Procedure
Steelguard CM 4705 must be thoroughly stirred Application Data
before used. Thinner .................................. Do not thin
Shipping Data
Pack size ................................ 25 litre pails
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions
• Sealer coat for alkyd, unknown primers Physical Data
• Prevents primer saponification
• Adhesion promoter for primed steel Appearance ............................ matt
Theoretical coverage at 50
microns dry film thickness ..... 5.4 m²/litre
Surface Preparation
Ensure that the existing coating is clean, dry, sound Application Data
and free from any dirt, dust or contamination Substrate ................................ coated steel
immediately before coating. Any loose adherent
coating should be removed back to firm edge and Application method................. brush, roller, airless and
conventional spray
suitably patch repaired.
Environmental Conditions
Ambient temperature .......... 5 to 25°C 41 to 77ºF
Mixing Surface temperature: ........... 4°C/39ºF minimum
Steelguard CM 4706 must be thoroughly stirred
before use. Surface temperature must be at least 2°C/4°F above the dew point
to prevent moisture condensation on the surface.
Shipping Data
Pack size ................................ 25 litre pails
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Peintures Intumescentes
> START
We Know...
Fire Protection
Coatings
Amercoat
®
Pitt-Char XP
Revêtement Epoxy Intumescent
Fiche technique/
Instructions d'application Caractéristiques physiques
Aspect du produit sec............. brillant
• Protection supérieure au feu et à la corrosion
Couleur................................... gris
• Flexibilité unique
• Résistance mécanique supérieure Composants ........................... 2
• Approprié pour une exposition cryogénique
Rapport de mélange
• Respecte les standards internationaux relatifs en volume ............................ 2.33 part A pour 1 part B
au feu en poids ............................... 3.25 part A pour 1 part B
A-60 IMO RES A 0.517(13) 8.0 mm (0.31”) Matériel d'application* ............ Pompe multi composants à chaud
Inflammabilité de ASTM E-84, UL 723 Propagation de la ou pompe airless pour matériau
surface Tunnel Test as part of flamme=15 épais
UL 263 Développement de la
fumée=70-110 Conditions d'application
Essai de colonne UL 263 “Fire Tests of 1 hr: 4.8 mm (0.19”) Température de l'air............. 10-50 °C
UL No. X-623 Building Construction 1½ hr: 6.6 mm (0.26”) Température du support ...... 10-60 °C
Materials” 2 hr: 8.6 mm (0.34”)
2½ hr: 10.7 mm (0.42”) La température de surface doit être au mois de 3°C au-dessus du
3 hr: 13.5 mm (0.53”) point de rosée pour éviter toute condensation sur la surface.
Essai de colonne UL 1709 “Essais au feu 1 hr: 7.1 mm (0.28”)
UL No. XR-612 sur la résistance de la 1½ hr: 10.2 mm (0.40”) Durée de vie en pot** ............. 40 minutes à 25°C
protection des aciers 2 hr: 13.2 mm (0.52”)
structurels à la montée 2½ hr: 16.0 mm (0.63”) Durée de réticulation*** (°C) 38 24 16 4
en température rapide 3 hr: 19.1 mm (0.75”) Pour une dureté Shore A50. 4 hr 10 hr 36 hr 72 hr
des feux ”
Feu de kérozene OTI 95-634 ”Jet Fire Protection jusqu'à 2
Resistance Test of hrs. Sur paroi, 1 heure * Pitt-Char XP est disponible en 2 composants, vérifier auprès de
Passive Fire Protection sur section I et section votre représentant PPG Protective & Marine Coatings pour des
Materials” creuse recommandations spécifiques.
Bac de stockage US – DOT Protection jusqu'à 4
LPG/LNG France - GASAFE heures ** La durée de vie en pot n'est pas considérée lorsqu'une pompe
spéciale airless multi composants est utilisée
Propriétés environnementales:
Test conduit par Underwriters laboratories Inc. (UL) pour garantir le
maintien de la protection au feu (UL 263 et UL 1709 critères de tests)
Pitt-Char XP Coating a subi les tests suivants:
• Brouillard salin • Atmosphère industrielle (solution CO2-SO2 air)
• Humidité élevée • Cycle sec, humide et gel
• Brouillard de solvant • Vieillissement à la chaleur – 80°C durant 175
jours • Brouillard d'acide • Norsok M501: vieillissement accéléré et test
au feu d'hydrocarbure selon M501
Procédure d'application
L'application du système Pitt-Char XP exige un Pitt-Char FM™ Maille déployée
savoir-faire spécifique sur le matériel d'application, les
différents composants,, les conditions d'application, Mesh Description Dimension du rouleau Utilisations
les procédés et conditions d'application. Vérifier, Code
auprès de notre représentant PPG Protective & Fibre de verre, Rouleau de 1.2 x 45.7 m, Feu cellulosique et
238-2/66 maille 3.175 x 55.7 m2 par rouleau
Marine Coatings, toute information sur notre 3.175 mm, 152.2
hydrocarbure, acier
structurel (petites
programme de formation due l'applicateur. g/m² dimensions)
Fibre de verre, Rouleau de 1.2 x 45.7 m, Feu hydrocarbure et feu
238-4/66 maille 6.35x6.35 55.7 m2 par rouleau de kérosène de moins de
mm, 152.2 g/m² 30mn. Toute structure
importante d'acier
2
Pitt-Char FM maille Rouleau de1 x 50 m, 50 m Feu hydrocarbure et feu
238-5/66 déployée 203.4 par rouleau kérosène. Tous types
g/m2 d'acier.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Composants ........................... 1
• Peinture intumescente en couche fine,
solvantée. Extrait sec en volume*............ 68+/-3%
• Testée en laboratoires d’essais indépendants
Composants organiques volatils ( COV )**
suivant des normes internationales EC SED 1999/13/EC ........... 293 g/kg (378 g/l)
• Permet jusqu’à 2 heures de résistance au feu UK PG6/23(92) Appendix 3 . 325 g/l (2.7 lbs/gal)
des structures en acier
Durcissement ......................... évaporation de solvant
• Application sur site ou en atelier
• Application en une seule couche de 1,5 mm Epaisseur requise.................... Dans le but d'établir l'épaisseur
sec sèche permettant la résistance au
feu demandée, se référer au
• Permet un travail rapide coefficient de massivité A/V m
-1
Epaisseur humide (µm) .......... 370 590 740 1030 1470 2205
Principales utilisations Pouvoir couvrant théorique (m²/l) 2,72 1,70 1,36 0,97 0,68 0.45
Protection intumescente pour la résistance au feu de
structures en acier en intérieur de bâtiments. (Epaisseurs humides théoriques pour une couche appliquée au
pistolet airless)
Steelguard FM 549 convient pour une application en
atelier ou sur site. Masse volumique ................... 1,3 kg/l
Point éclair
Agréments (vase clos) .......................... ºC ºF
Le steelguard FM 549 a été testé suivant des normes Steelguard FM 549 .............. 25 77
Amercoat 65 ........................ 24 75
nationales et internationales pour l'exposition aux
feux cellulosiques (ISO 834) et a été évalué et certifié * L’extrait sec en volume est mesuré suivant la norme ASTM D2697
suivant des exigences de différent pays. Veuillez modifiée. De légères variations (± 3 %) peuvent être relevées en
fonction de la teinte et de la méthode de mesure.
contacter votre représentant PPG concernant les
réglementations locales en vigueur et les dernières ** COV : les valeurs indiquées pour la directive EC 1999/13 sont
certifications. Pour un projet précis, si applicable, des valeurs théoriques calculées et celles indiquées pour le
document UK PG6/23(92) annexe 3 sont des valeurs pratiques
PPG Protective and Marine Coatings pourra fournir mesurées.
aux clients les éléments nécessaires aux exigences
stipulées pour la protection au feu: les épaisseurs de
matériaux, les calculs de consommation peinture, la
désignation des sections acier et la réglementation
locale.
APPROVED PRODUCT
CF 459
Temps de séchage
Les temps de séchage varient considérablement en fonction
des conditions ambiantes, de la méthode d'application, du
coefficient de massivité A/V m-1 (Hp/A) et de l'épaisseur du film
appliqué. Par exemple, à 15°C, une couche de 400 μm
d'épaisseur sèche sera sèche au toucher en 1 heure
approximativement et sec apparent complet après 40 heures
environ. Pour plus de détails sur les temps de séchage du
Steelguard FM 549, se référer aux tableaux de séchage ou
contacter votre représentant PPG.
Recouvrement
La finition standard recommandée sur le Steelguard FM 549
est le Steelguard 2458 qui permet un recouvrement et un
travail rapide. D'autres finitions sont approuvées bien qu'ayant
un intervalle de recouvrement plus long tels que l'Amercoat
450S, Amercoat 4310, Amercoat 2136 et PSX 700#. Aucune
couche isolante n'est nécessaire en ambiance intérieure C1 si
aucune exigence esthétique n'est demandée. Pour une
utilisation en ambiance intérieure C2 Steelguard FM 549 doit
être correctement isolé avec du Steelguard 2458 à une
épaisseur sèche de 60 μm ou par d'autres finitions approuvées.
Veuillez contacter votre représentant PPG pour des
recommandations spécifiques. Il est important que les
épaisseurs spécifiées de l'intumescent soient correctement
obtenues avant tout recouvrement
(#Amercoat 71TC est requis en tant que couche isolante)
Procédure d’application:
1. Rincer l’équipement avec le diluant recommandé avant
utilisation.
2. Homogénéiser le produit (dans le bidon) à l’aide d’un malaxeur
mécanique.
3. La dilution n’est en général pas nécessaire pour une
pulvérisation airless.
4. Malaxer pendant l’application afin de conserver l’homogénéité
du produit. Appliquer un film humide en passes égales et
parallèles. Chevaucher à 50 % chaque passe afin d’éviter les
manques, porosités et maigreurs.
5. Prendre un soin particulier sur les zones de soudures, les
zones rugueuses, les arrêtes et cornières, les rivets, boulons,
etc.
6. A titre d’exemple, l’application d’un film humide de 590 µm
permettra normalement d’obtenir un film sec de 400 µm.
7. Contrôler l’épaisseur du film sec à l’aide d’une jauge
d’épaisseur non destructive telle que Mikrotest, ou un
Elcometer. Si l’épaisseur relevée est inférieure à l’épaisseur
requise, ré-appliquer une nouvelle couche à l’épaisseur
nécessaire.
8. Les petits défauts, tels que : manque, porosité, faible
épaisseur, peuvent être corrigés à la brosse. Réparer les zones
plus importantes au pistolet ou à la brosse avec du Steelguard
FM 549 ou à la truelle, au couteau ou à la spatule avec du
Steelguard 2450.
9. En espaces confinés, assurer une ventilation d’air frais durant
l’application et le séchage jusqu’à évaporation complète des
solvants. La température et l’humidité de l’air de ventilation
doivent être réglées de façon à éviter toute condensation sur la
surface.
10. Nettoyer tout le matériel avec le nettoyant recommandé
immédiatement après utilisation ou au maximum à la fin de
chaque journée de travail ou au changement d’équipe.
Conditions de vente
Se référer aux conditions de vente particulières.
Fiche Technique/
Instructions d’application Caractéristiques physiques
Aspect du produit sec............. Mat
Principales utilisations Epaisseur humide (µm) .......... 370 590 740 1030 1470 2205
Peinture intumescente pour la protection contre le feu des
Pouvoir couvrant théorique (m²/l)2,72 1,70 1,36 0,97 0,68 0.45
structures en acier en intérieur ou en l’extérieur.
Le Steelguard FM 550 peut être également appliqué en (Epaisseurs humides théoriques pour une couche appliquée
atelier en manuel par pistolet Airless ou en application pistolet airless)
automatique avec installations de pré-chauffage et de
séchage accéléré. Masse volumique ................... 1,3 kg/l
Point éclair
(vase clos) ........................... ºC ºF
Agréments Steelguard FM 550 .............. 25 77
Le steelguard FM 550 a été testé suivant des normes Amercoat 65 ........................ 24 75
nationales et internationales pour l'exposition aux feux
cellulosiques (ISO 834) et a été évalué et certifié suivant
des exigences de différent pays. Veuillez contacter votre * L’extrait sec en volume est mesuré suivant la norme ASTM D2697
représentant PPG concernant les réglementations locales modifiée. De légères variations (± 3 %) peuvent être relevées en
fonction de la teinte et de la méthode de mesure.
en vigueur et les dernières certifications. Pour un projet
précis, si applicable, PPG Protective and Marine Coatings ** COV : les valeurs indiquées pour la directive EC 1999/13 sont des
pourra fournir aux clients les éléments nécessaires aux valeurs théoriques calculées et celles indiquées pour le document UK
exigences stipulées pour la protection au feu: les PG6/23(92) Appendix 3 sont des valeurs pratiques mesurées.
épaisseurs de matériaux, les calculs de consommation
peinture, la désignation des sections acier et la
réglementation locale.
APPROVED PRODUCT
CF 456
Méthodes d’application
Une application par pulvérisation apportera une meilleure
finition
PISTOLET AIRLESS – Utiliser une pompe capable de produire
une pression minimum à la buse de 2800 psi (200 kg/cm²). Un
filtre 30 mesh/ 500 μm est recommandé. Buse de 0,48-0,83
mm (0,019 à 0,33 pouces) Pour une application en extérieur, il
est recommandé d'appliquer les couches à des épaisseurs
sèches de 700µm en permettant un séchage minimum de 8
heures à 15°C/59ºF entre chaque couche. Pour une application
en intérieur, de plus fortes épaisseurs peuvent être appliqués
en une seule application, il est alors recommandé de limiter
l'épaisseur de la première couche à 1.5mm. Les couches
suivantes, peuvent être appliquées après 8heures de séchage
à 20°C/68ºF et à une épaisseur maximum de 1.0 mm par
couche.
BROSSE – Appliquer en utilisant une brosse propre et bien
chargée jusqu'à une épaisseur sèche de 300 μm par couche.
En règle générale, permettre un séchage d'au moins 2 heures
à 20°C/68ºF entre couches.
Temps de séchage
Les temps de séchage variant considérablement en fonction
des conditions ambiantes, de la méthode d'application, des
conditions éventuelles de pré-chauffage et de séchage forcé,
du coefficient de massiveté A/V m-1 (Hp/A) et de l'épaisseur du
film appliqué. Par exemple, à 15°C/59ºF une couche de 400
μm d'épaisseur sèche sera sèche au toucher en 1 heure
approximativement et sec apparent complet après 40 heures
environ. Pour plus de détails sur les temps de séchage du
Steelguard FM 550, se référer aux tableaux de séchage ou
contacter votre représentant PPG.
Recouvrement
La finition standard recommandée sur le Steelguard FM 550 est le Données d'expédition
Steelguard 2458 qui permet un recouvrement et un travail rapide.
D'autres finitions sont approuvées bien qu'ayant un intervalle de Conditionnement .................... 20 et 200 litres
recouvrement plus long tels Amercoat 450S, Amercoat 4310,
Amercoat 2136 et PSX 700#. Aucune finition n'est nécessaire en Poids brut ............................... environ 29 kg (20 l)
environnement intérieure C1 si aucune exigence esthétique n'est
Durée de vie ........................... 1 an à compter de la date
demandée. Pour une utilisation en ambiance intérieure C2
d’expédition ou selon l’indication de
Steelguard FM 550 doit être correctement isolé avec du Steelguard
l'étiquette, pour un produit stocké à
2458 à une épaisseur sèche de 60 μm ou par d'autres finitions
l’abri dans le conditionnement
approuvées. Pour une utilisation en environnement C3 et C4,
d’origine fermé à une température
Steelguard FM 550 doit être correctement recouvert avec 2
entre 5 et 40°C (41 - 104ºF).
couches de Steelguard 2458 à une épaisseur sèche de 120 μm ou
par une autre finition approuvée. Veuillez contacter votre
représentant PPG pour des recommandations spécifiques. Il est
important que les épaisseurs spécifiées de l'intumescent soient
correctement obtenues avant tout recouvrement
En supposant que l'acier soit correctement recouvert d'un primaire
et que l'épaisseur sèche de l'intumescent est supérieure à 250 μm,
Steelguard FM 550 peut être laissé en extérieur sans couche de
finition jusqu'à 12 mois. Néanmoins, durant cette période, le
Steelguard FM 550 doit être protégé de l'eau ruisselante, de la
chaleur et ne pas être immergé. Steelguard FM 550 doit être
suffisamment sec avant d'être exposé en extérieur. Par exemple, à
15°C/59ºF, pour une épaisseur sèche de 700 μm, un temps de
séchage minimum de 40 heures est recommandé depuis la fin de
l'application de la couche finale avant exposition.
Se référer aux tableaux de séchage du produit pour programmer
les séchages et recouvrement.
Procédure d’application:
1. Rincer l’équipement avec le diluant recommandé avant
utilisation.
2. Homogénéiser le produit (dans le bidon) à l’aide d’un malaxeur
mécanique.
3. La dilution n’est en général pas nécessaire pour une projection
airless.
4. Malaxer pendant l’application afin de conserver l’homogénéité
du produit. Appliquer un film humide en passes égales et
parallèles. Chevaucher à 50 % chaque passe afin d’éviter les
manques, porosités et maigreurs.
5. Prendre un soin particulier sur les zones de soudures, les
zones rugueuses, les arrêtes et cornières, les rivets, boulons,
etc.
6. A titre d’exemple, l’application d’un film humide de 590 µm
permettra normalement d’obtenir un film sec de 400 µm.
7. Contrôler l’épaisseur du film sec à l’aide d’une jauge
d’épaisseur non destructive tel que Mikrotest, ou un Elcometer.
Si l’épaisseur relevée est inférieure à l’épaisseur requise, ré-
appliquer une nouvelle couche à l’épaisseur nécessaire.
8. Les petits défauts, tels que : manque, porosité, faible
épaisseur, peuvent être corrigés à la brosse. Réparer les zones
plus importantes au pistolet ou à la brosse avec du Steelguard
FM 550 ou à la truelle, au couteau ou à la spatule avec du
Steelguard 2450.
9. Dans le cas de réparation de systèmes sans primaire ou l’acier
nu est exposé, un primaire compatible sera appliqué avant ré-
application de la peinture intumescente.
10. En espaces confinés, assurer une ventilation à l’air frais durant
l’application et le séchage jusqu’à évaporation complète des
solvants. La température et l’humidité de l’air de ventilation
doivent être réglées de façon à éviter toute condensation sur la
surface.
11. Nettoyer tout le matériel avec le nettoyant recommandé
immédiatement après utilisation ou au maximum à la fin de
chaque journée de travail ou au changement d’équipe.
Conditions de vente
Se référer aux conditions de vente particulières.
Fiche Technique/
Instructions d’application Caractéristiques physiques
Aspect du produit sec............. Mat
• Peinture intumescente applicable en couche fine, Couleur................................... Blanc, gris
solvantée.
• Permet jusqu’à 60 minutes de résistance au feu Composants ........................... 1
des structures en acier Extrait sec en volume*............ 75+/-3%
• Application en atelier et sur site
Composants organiques volatils ( COV )**
• Application en une seule couche de 1,5 mm sec EC SED 1999/13/EC ........... 257 g/kg (346 g/l)
• Pour une utilisation en intérieur et extérieur dans UK PG6/23(92) Appendix 3 . 330 g/l
un environnement de type C1, C2, C3 et C4 - il
n'est pas nécessaire d'appliquer une finition Durcissement ......................... évaporation de solvant
isolante pour les intérieurs secs de type C1 (ISO Epaisseur requise.................... Dans le but d'établir l'épaisseur
12944) sèche permettant la résistance au
feu demandée, se référer au
-1
Principales utilisations coefficient de massiveté A/V m
(Hp/A) ou au tableau de limites de
Protection intumescente pour la résistance au feu des
températures.
structures en acier en intérieur ou en l’extérieur. Idéal pour les
poutres, les charpentes métalliques et les profilés creux de Epaisseur de film sec type (µm) 200 400 500 700 1000
section en I. Conçu pour une application en intérieur par
pompe airless. Peut également être appliqué à la brosse. Epaisseur humide (µm) .......... 270 535 665 935 1335
Egalement approprié pour une application en extérieur soit par
pompe airless ou par application automatique avec installations Pouvoir couvrant théorique (m²/l)3.75 1.88 1.50 1.07 0.75
de préchauffage et de séchage accéléré. Le Steelguard 551
Masse volumique ................... 1,35 kg/l
est résistant aux intempéries jusqu'à 12 mois en conditions
normales facilitant ainsi le transport, le stockage et les phases Point éclair
d'érection dans les projets de construction. Pendant ces (vase clos) ........................... ºC
périodes, éviter le ruissellement d'eau, les environnements Steelguard FM 550 .............. 25
humides et chauds et l'immersion. Amercoat 65 ........................ 24
APPROVED PRODUCT
CF 551
Préparation de surface
Application sur un subjectile convenablement décapé par Instructions d’application
projection d’abrasifs et recouvert d'un primaire approprié. La
surface doit être sèche et exempte de poussières, sels, graisse Subjectile................................ Acier revêtu d’un primaire
et autres contaminants immédiatement avant recouvrement. Le
Matériel d’application.............. Pistolet airless, Brosse
primaire utilisé doit être appliqué suivant les instructions
spécifiques de la fiche technique, et doit être approuvé par Conditions d’application
PPG pour s'assurer de la compatibilité avec le Steelguard
551.les primaires PPG appropriés incluent Amercoat 71, Hygrométrie : ......... inférieure à 85 %
Amercoat 139, Amercoat 182ZPHB, Amercoat 3146P, Température du support : ...... 5 - 50°C
Amercoat 4116, Steelguard 3290 et la série Amercoat 68. Température de l'air ............... 5 - 50°C
L'épaisseur sèche totale du primaire ne doit pas dépasser 150
μm. Pour les primaires époxy l'épaisseur maximale autorisée La température de surface doit être au moins de 3°C au-dessus du
point de rosée.
peut être plus importante, veuillez consulter votre représentant
PPGavant d'appliquer le revêtement intumescent. Diluant .................................... normalement pas nécessaire
Pour les applications en atelier, le Steelguard 561 peut être Le diluant Amercoat 65 peut être utilisé si nécessaire jusqu'à 5%
appliqué directement sur acier convenablement grenaillé pour en volume.
des utilisations en environnement intérieur de classe C1. Dans Dans ce cas, les mesures des épaisseurs de couche humide en
ce cas, l’épaisseur sèche devra être supérieure à 400 µm. seront modifiées et il devra être pris en compte la réduction de
L’acier devra être décapé par projection d’abrasifs au degré de l'épaisseur du film sec.
soins Sa 2½ selon la norme ISO 8501-1 avec une rugosité
d’environ Rz=50-75 microns sans dépasser 100 microns. Le Nettoyant ................................ Amercoat 65
revêtement sera appliqué avant que le degré de soin ne se
dégrade. En cas de ré-oxydation du subjectile, celui-ci sera
décapé de nouveau. La surface doit être sèche et exempte de
poussières, sels, graisse et autres contaminants
immédiatement avant recouvrement.
Mélange
Homogénéiser le Steelguard 551 jusqu'à mélange complet. Il
peut être constaté une apparence de produit dilué, ce qui est
normal pour ce produit. Utiliser un malaxeur commandé par air
comprimé ou électrique.
Méthodes d’application
PISTOLET AIRLESS – Utiliser une pompe capable de produire
une pression minimum à la buse de 2800 psi (200 kg/cm²). Un
filtre 30 mesh/ 500 μm est recommandé. Buse de 0,48-0,63
mm (0,019 à 0,25 pouces) Pour une application en intérieur,
Steelguard 551 peur être appliqué en une seule couche jusqu'à
1,5 mm. Pour une application en extérieur, il est recommandé
d'appliquer les couches à des épaisseurs sèches de 700µm en
respectant un séchage minimum de 8 heures à 15°C entre
chaque couche.
BROSSE – Appliquer en utilisant une brosse propre et bien
chargée jusqu'à une épaisseur sèche de 300 μm par couche.
En règle générale, permettre un séchage d'au moins 2 heures
à 20°C entre couches.
Temps de séchage
Les temps de séchage variant considérablement en fonction
des conditions ambiantes, du coefficient de massiveté A/V m-1
(Hp/A) et de l'épaisseur du film appliqué. Par exemple, à 15°C
une couche de 700 μm d'épaisseur sèche sera sèche au
toucher en 1 heure et sec apparent complet après
approximativement 40 heures. Pour plus de détails sur les
temps de séchage du Steelguard 551, se référer aux tableaux
de séchage ou contacter votre représentant PPG.
Recouvrement
La finition standard recommandée sur le Steelguard 551 est le
Steelguard 2458 qui permet un recouvrement et un travail
rapide. D'autres finitions sont approuvées bien qu'ayant un
intervalle de recouvrement plus long tels Amercoat 450 série,
Amercoat 4310, Amercoat 2136 et PSX 700#. Aucune finition
Procédure d’application :
1. Rincer l’équipement avec le diluant recommandé avant
utilisation.
2. Homogénéiser le produit (dans le bidon) à l’aide d’un malaxeur
mécanique.
3. La dilution n’est en général pas nécessaire pour une projection
airless.
4. Malaxer pendant l’application afin de conserver l’homogénéité
du produit. Appliquer un film humide en passes égales et
parallèles. Chevaucher à 50 % chaque passe afin d’éviter les
manques, porosités et maigreurs.
5. Prendre un soin particulier sur les zones de soudures, les
zones rugueuses, les arrêtes et cornières, les rivets, boulons,
etc.
6. A titre d’exemple, l’application d’un film humide de 540 µm
permettra normalement d’obtenir un film sec de 400 µm.
7. Contrôler l’épaisseur du film sec à l’aide d’une jauge
d’épaisseur non destructive tel que Mikrotest, ou un Elcometer.
Si l’épaisseur relevée est inférieure à l’épaisseur requise, ré-
appliquer une nouvelle couche à l’épaisseur nécessaire.
8. Les petits défauts doivent être réparés avec du Steelguard
2451 Produit intumescent de réparation. Réparer les zones
plus importantes au pistolet ou à la brosse avec du Steelguard
551.
9. Dans le cas de réparation de systèmes sans primaire ou l’acier
nu est exposé, un primaire compatible sera appliqué avant ré-
application de la peinture intumescente.
10. En espaces confinés, assurer une ventilation à l’air frais durant
l’application et le séchage jusqu’à évaporation complète des
solvants. La température et l’humidité de l’air de ventilation
doivent être réglées de façon à éviter toute condensation sur la
surface.
11.Nettoyer tout le matériel avec le nettoyant recommandé
immédiatement après utilisation ou au maximum à la fin de chaque
journée de travail ou au changement d’équipe.
Conditions de vente
Se référer aux conditions de vente particulières.
Fiche Technique/
Instructions d’application Caractéristiques physiques
Aspect du produit sec............. Mat
APPROVED PRODUCT
CF 457
Préparation de surface
Appliquer sur un subjectile convenablement décapé par intervalle de recouvrement plus long tels que Amercoat 450S,
projection d'abrasifs et recouvert d'un primaire approprié. La Amercoat 4310, Amercoat 2136 et PSX 700#. Aucune finition
surface doit être sèche et exempte de poussières, sels, graisse n'est nécessaire en environnement intérieure C1 si aucune
et autres contaminants immédiatement avant recouvrement. Le exigence esthétique n'est demandée. Pour une utilisation en
primaire utilisé doit être appliqué suivant les instructions ambiance intérieure C2, Steelguard 560 doit être correctement
spécifiques de la fiche technique, et doit être approuvé par isolé avec du Steelguard 2458 à une épaisseur sèche de 60
PPG pour s'assurer de la compatibilité avec le Steelguard 560. μm ou par une autre finition approuvée. Pour une utilisation en
L'épaisseur sèche totale du primaire ne doit pas dépasser 150 environnement C3 et C4, Steelguard 560 doit être
μm. Pour les primaires époxy, l'épaisseur maximale autorisée correctement recouvert avec 2 couches de Steelguard 2458 à
peut être plus importante, veuillez consulter votre représentant une épaisseur sèche totale de 120 μm ou par une autre finition
PPG avant d'appliquer le revêtement intumescent. approuvée. Veuillez contacter votre représentant PPG pour des
En atelier, le Steelguard 560 peut être appliqué directement sur recommandations spécifiques. Il est important que les
l'acier préparé pour un usage en environnement intérieur de épaisseurs spécifiées de l'intumescent soient correctement
classe C1 et à condition que l'épaisseur sèche soit supérieuree obtenues avant tout recouvrement.
à 400 µm. Le subjectile acier devra alors être décapé par En supposant que l'acier soit correctement recouvert d'un
projection d'abrasifs au degré Sa 2 ½ (selon le standard ISO primaire et que l'épaisseur sèche de l'intumescent soit
8501-1) avec une rugosité de 50-75µm. Le revêtement sera supérieure à 250 μm, Steelguard 560 peut être laissé en
appliqué avant que le degré de soin ne se dégrade. En cas de extérieur sans couche de finition pendant 12 mois. Néanmoins,
ré-oxydation du subjectile, celui-ci sera décapé de nouveau. La durant cette période, le Steelguard 560 doit être protégé de
surface doit être sèche et exempte de poussières, sels, graisse l'eau ruisselante, de la chaleur et ne pas être immergé.
et autres contaminants immédiatement avant recouvrement. Steelguard 560 doit être suffisamment sec avant d'être exposé
en extérieur. Par exemple, à 15°C, pour une épaisseur sèche
de 700 μm, un temps de séchage minimum de 20 heures est
Mélange recommandé après la fin de l'application de la couche finale
Homogénéiser le Steelguard 560 jusqu'à parfait mélange. Il est avant exposition.
normal de constater une consistance du produit plus liquide
après mélange. Utiliser un malaxeur mécanique suffisamment Se référer aux tableaux de séchage du produit pour
puissant. programmer les séchages et recouvrement
Recouvrement
La finition standard recommandée sur le Steelguard 560 est le
Steelguard 2458 qui permet un recouvrement et un travail
rapide. D'autres finitions sont approuvées bien qu'ayant un
Procédure d’application
1. Rincer l’équipement avec le diluant recommandé avant Données d'expédition
utilisation.
2. Homogénéiser le produit (dans le bidon) à l’aide d’un malaxeur Conditionnement .................... 20 et 200 litres
mécanique.
3. La dilution n’est en général pas nécessaire pour une projection Poids brut ............................... environ 29 kg (20 l)
airless. Durée de vie 1 an à compter de la date
4. Malaxer pendant l’application afin de conserver l’homogénéité d’expédition ou selon l’indication de l'étiquette, pour un produit
du produit. Appliquer un film humide en passes égales et stocké à l’abri dans le conditionnement d’origine fermé à une
parallèles. Chevaucher à 50 % chaque passe afin d’éviter les température entre 5 et 40°C (41 - 104ºF)
manques, porosités et maigreurs.
5. Prendre un soin particulier sur les zones de soudures, les
zones rugueuses, les arrêtes et cornières, les rivets, boulons,
etc.
6. A titre d’exemple, l’application d’un film humide de 590 µm
permettra normalement d’obtenir un film sec de 400 µm.
7. Contrôler l’épaisseur du film sec à l’aide d’une jauge
d’épaisseur non destructive tel que Mikrotest, ou un Elcometer.
Si l’épaisseur relevée est inférieure à l’épaisseur requise, ré-
appliquer une nouvelle couche à l’épaisseur nécessaire.
8. Les petits défauts, tels que : manque, porosité, faible
épaisseur, peuvent être corrigés à la brosse. Réparer les zones
plus importantes au pistolet ou à la brosse avec du Steelguard
560 ou à la truelle, au couteau ou à la spatule avec du
Steelguard 2450.
9. Dans le cas de réparation de systèmes sans primaire ou l’acier
nu est exposé, un primaire compatible sera appliqué avant ré-
application de la peinture intumescente.
10. En espaces confinés, assurer une ventilation à l’air frais durant
l’application et le séchage jusqu’à évaporation complète des
solvants. La température et l’humidité de l’air de ventilation
doivent être réglées de façon à éviter toute condensation sur la
surface.
11. Nettoyer tout le matériel avec le nettoyant recommandé
immédiatement après utilisation ou au maximum à la fin de
chaque journée de travail ou au changement d’équipe.
Conditions de vente
Se référer aux conditions de vente particulières.
Composants ........................... 1
• Peinture intumescente solvantée, applicable en couche
Extrait sec en volume*............ 75+/-3%
fine, à séchage rapide
• Permettant un temps de manipulation réduit Composants organiques volatils ( COV )**
• Permet jusqu’à 60 minutes de résistance au feu des EC SED 1999/13/EC ........... 255 g/kg (343 g/l)
structures en acier UK PG6/23(92) Appendix 3 . 327 g/l
• Application en atelier et sur site Durcissement ......................... évaporation de solvant
• Application en une seule couche jusqu'à 1 mm sec
Epaisseur requise.................... Dans le but d'établir l'épaisseur
• Pour une utilisation en intérieur et extérieur pour des sèche permettant la résistance au
environnements C1, C2, C3 ou C4. Il n'est pas feu demandée, se référer au
nécessaire d'appliquer une finition isolante pour les coefficient de massivité A/V m
-1
APPROVED PRODUCT
CF 561
Page 1 sur 4 Révision: 02-09-2008
Steelguard 561
Préparation de surface
Application sur un subjectile convenablement décapé par Instructions d’application
projection d'abrasifs et recouvert d'un primaire approprié. La
Support................................... Acier revêtu d’un primaire
surface doit être sèche et exempte de poussières, sels, graisse
et autres contaminants immédiatement avant recouvrement. Le Matériel d’application Pistolet airless,Brosse (petites
primaire utilisé doit être appliqué suivant les instructions surfaces)
spécifiques de la fiche technique et doit être approuvé par PPG
pour s'assurer de la compatibilité avec le Steelguard FM 561. Conditions d’application
Les primaires PPG appropriés incluent Amercoat 71, Amercoat Hygrométrie : ...... inférieure à 85 %
139, Amercoat 182ZPHB, Amercoat 3146P, Amercoat 4116, Température du support : ... 5 - 40°C
Steelguard 3290 et la série Amercoat 68. L'épaisseur sèche Température de l'air............. 5 - 40°C
totale du primaire ne doit pas dépasser 150 μm. Pour les
primaires époxy, l'épaisseur maximale autorisée peut être plus La température de surface doit être au moins de 3°C au-dessus du
point de rosée.
importante, veuillez consulter votre représentant PPG avant
d'appliquer le revêtement intumescent. Diluant .................................... En général pas nécessaire
Pour les applications en atelier, le Steelguard 561 peut être Le diluant Amercoat 65 peut être utilisé si nécessaire
appliqué directement sur acier convenablement grenaillé pour jusqu'à 5% en volume.
des utilisations en environnement intérieur de classe C1. Dans
Dans ce cas, les mesures des épaisseurs de couche
ce cas, l'épaisseur sèche devra être supérieure à 400 µm.
L'acier devra être décapé par projection d'abrasifs au degré de
humide en seront modifiées et il devra être pris en compte
soins Sa 2 ½ selon la norme ISO 8501-1 avec une rugosité la réduction de l'épaisseur du film sec.
d'environ Rz=50-75 microns sans dépasser 100 microns. Le Nettoyant ................................ Amercoat 65
revêtement sera appliqué avant que le degré de soin ne se
dégrade. En cas de ré-oxydation du subjectile, celui-ci sera
décapé de nouveau. La surface doit être sèche et exempte de
poussières, sels, graisse et autres contaminants
immédiatement avant recouvrement.
Mélange
Homogénéiser le Steelguard 561 jusqu'à mélange complet. Il
peut être constaté une apparence de produit dilué ce qui est
normal pour ce produit. Utiliser un malaxeur commandé par air
comprimé ou électrique.
Méthodes d’application
PISTOLET AIRLESS – Utiliser une pompe capable de produire
une pression minimum à la buse de 2800 psi (200 kg/cm²). Un
filtre 30 mesh/ 500 μm est recommandé. Buse de 0,48-0,63
mm (0,019 à 0,25 pouces) Pour une application en extérieur, il
est recommandé d'appliquer les couches à des épaisseurs
sèches de 700µm en permettant un séchage minimum de 6
heures à 15°C entre chaque couche.
BROSSE – Recommandé seulement pour de petites surfaces
ou pour des réparations. Appliquer en utilisant une brosse
propre et bien chargée jusqu'à une épaisseur sèche de 300 μm
par couche. En règle générale, permettre un séchage d'au
moins 2 heures à 20°C entre couches.
Temps de séchage
Les temps de séchage variant considérablement en fonction
des conditions ambiantes, du coefficient de massivité A/V m-1
(Hp/A) et de l'épaisseur du film appliqué. Par exemple, à 15°C
une couche de 700 μm d'épaisseur sèche sera sèche au
toucher en 30 minutes et sec à cœur après approximativement
20 heures. Pour plus de détails sur les temps de séchage du
Steelguard 561, se référer aux tableaux de séchage ou
contacter votre représentant PPG.
Recouvrement
La finition standard recommandée sur le Steelguard 561 est le
Steelguard 2458 qui permet un recouvrement et un travail
rapide.
Procédure d’application
1. Rincer l’équipement avec le diluant recommandé avant
utilisation.
2. Homogénéiser le produit (dans le bidon) à l’aide d’un malaxeur
mécanique.
3. La dilution n’est en général pas nécessaire pour une projection
airless.
4. Malaxer pendant l’application afin de conserver l’homogénéité
du produit. Appliquer un film humide en passes égales et
parallèles. Chevaucher à 50 % chaque passe afin d’éviter les
manques, porosités et maigreurs.
5. Prendre un soin particulier sur les zones de soudures, les
zones rugueuses, les arrêtes et cornières, les rivets, boulons,
etc.
6. A titre d’exemple, l’application d’un film humide de 540 µm
permettra normalement d’obtenir un film sec de 400 µm.
7. Contrôler l’épaisseur du film sec à l’aide d’une jauge
d’épaisseur non destructive tel que Mikrotest, ou un Elcometer.
Si l’épaisseur relevée est inférieure à l’épaisseur requise, ré-
appliquer une nouvelle couche à l’épaisseur nécessaire.
8. Les petits défauts doivent être réparés avec du Steelguard
2451 Produit intumescent de réparation. Réparer les zones
plus importantes au pistolet avec du Steelguard 561.
9. Dans le cas de réparation de systèmes sans primaire ou l’acier
nu est exposé, un primaire compatible sera appliqué avant ré-
application de la peinture intumescente.
10. En espaces confinés, assurer une ventilation à l’air frais durant
l’application et le séchage jusqu’à évaporation complète des
solvants. La température et l’humidité de l’air de ventilation
doivent être réglées de façon à éviter toute condensation sur la
surface.
11. Nettoyer tout le matériel avec le nettoyant recommandé
immédiatement après utilisation ou au maximum à la fin de
chaque journée de travail ou au changement d’équipe.
Conditions de vente
Se référer aux conditions de vente particulières.
Principales utilisations Epaisseur du feuil sec (µm) ... 250 400 500 700
Protection intumescent des structures métalliques intérieures
dans un environnement classé C1 selon la norme ISO 12944 Epaisseur du film humide (µm) 360 570 715 1000
tels que bureaux, hôpitaux, écoles, magasins. Hydrodiluable et Rendement d'application théorique (m²/l)
émettant très peu d’odeur il apporte une alternative sans 2.80 1.75 1.40 1.00
danger et adéquate pour l'application sur site dans des milieux
confinés. (Les épaisseurs humides données sont théoriques pour une
application à la pompe airless)
APPROVED PRODUCT
CF 458
Temps de séchage
Les temps de séchage varient considérablement en fonction
des conditions ambiantes, de la ventilation, de la méthode
d'application du coefficient de massiveté A/V m-1 (Hp/A) et de
l'épaisseur du film appliqué. Par exemple, à 20°C/68ºF et 50%
d'hygrométrie, une couche de 400 μm d'épaisseur sèche sera
sèche au toucher en 2 heures approximativement et sec à
cœur après 4 heures environ. Pour plus de détails sur les
temps de séchage du Steelguard FM 580, se référer aux
tableaux de séchage ou contacter votre représentant PPG.
Recouvrement
Bien qu’il ne soit pas nécessaire de recouvrir le Steelguard 580
pour des environnements C1, il est possible pour des raisons
décoratives d’appliquer les Amercoat 220 qui sont les finitions
en phase aqueuse recommandées.
Steelguard FM 580 devra sécher au minimum 4 heures à 20°C
avant de le recouvrir avec l’Amercoat 220.
Pour plus de détails concernant la compatibilité avec d’autres
finitions comme le Steelguard 2458, merci de contacter votre
représentant PPG. Il est important que l’épaisseur de la couche
intumescente spécifiée soit appliquée avant de recouvrir..
Procédure d'application
1. Nettoyer le matériel avec un diluant adéquat, puis Données d'expédition
rincer abondamment à l'eau douce avant Conditionnement .................... 20 litres
utilisation.
2. Homogénéiser le produit et continuer à le brasser Poids brut .............................. environ. 28 kg
jusqu'à obtention d'un aspect uniforme. La Durée de vie .......................... 1 an à compter de la date
dilution n'est pas requise. d'expédition pour un produit stocké
3. Pour une application au pistolet Airless, appliquer à l'abri dans son conditionnement
d'origine fermé, à une température
un feuil humide en passes égales et parallèles. comprise entre 5 et 40°C (41 -
Chevaucher chaque passe à 50% pour éviter les 104ºF).
manques, porosités et maigreurs.
4. Doubler la couche sur les soudures, les aspérités, Doit être protégé du froid.
les arêtes vives et les recoins, les rivets, les
boulons, etc.
5. L’application d’un feuil humide à 570µm donnera
normalement un feuil sec de 400µm.
6. . Contrôler l’épaisseur du feuil sec avec une jauge
d’épaisseur non destructive de type Mikrotest ou
Elcometer. Si la mesure est inférieure à
l’épaisseur spécifiée, appliquer un nouveau voile
de peinture.
7. Les petites surfaces endommagées, les
manques, les maigreurs, les porosités peuvent
être reprises à la brosse. Les surfaces plus
grandes peuvent être reprises à la brosse, au
rouleau ou au pistolet Airless
8. Dans les espaces confinés, assurer une
circulation d’air frais durant l’application et le
séchage. Le taux d'humidité doit être maintenue
en dessous de 80%, la température maintenue de
façon à éviter toute condensation sur la surface.
9. Nettoyer tout le matériel avec de l'eau douce et
propre immédiatement après utilisation.
Avant d'utiliser le produit, lire l'étiquette sur le
bidon et consulter les fiches de données de
sécurité.
Conditions de vente
Se référer aux conditions de vente particulières.
Fiche Technique/
Instructions d’application Caractéristiques physiques
Aspect .................................... mat
• Revêtement hydrodiluable applicable en Couleur .................................. Blanc
couche fine pour utilisation sur site.
Nombre de composants ......... 1
• Odeur réduite et basse émission de
composants organiques volatils (COV) Durcissement ......................... Par évaporation de l’eau et
• Absence de chlore coalescence polymère
• Protection au feu des structures métalliques Extrait sec en volume*............ 70 ± 3%
jusqu'à 1 heure
• Pour une utilisation en intérieur sec en Composants organiques volatils ( COV )**
EC SED 1999/13/EC ........... 20 g/kg (29 g/l)
ambiance ambiance C1 (ISO12944) UK PG6/23(92) Appendix 3 . 30 g/l
• Applicable à 700 µm par couche
• Permet un travail rapide Epaisseur requise.................... Dans le but d'établir l'épaisseur
sèche permettant la résistance au
feu demandée, se référer au
-1
coefficient de massivité A/V m
Principales utilisations (Hp/A) ou au tableau de limites de
Protection intumescent des structures métalliques intérieures températures. Contacter votre
dans un environnement classé C1 (selon la norme ISO 12944) représentant PPG pour plus de
tels que bureaux, hôpitaux, écoles, magasins. Hydrodiluable et détails.
émettant très peu d'odeur, il apporte une alternative sans
danger et adéquate pour l'application sur site dans des milieux Epaisseur du feuil sec (µm).... 250 400 500 700
confinés.
Epaisseur du film humide (µm) 360 570 715 1000
Mélange
Remuer Steelguard FM 585 préalablement jusqu’à ce que le Instructions d’application
produit soit homogène. Un malaxeur mécanique doit être
Subjectile ............................... Acier décapé à l’abrasif recouvert
utilisé.
d’une couche primaire
Préparation des surfaces Méthode d'application ........... Pistolet sans air brosse, rouleau
Application sur un subjectile convenablement décapé par
projection d'abrasifs et recouvert d'un primaire approprié. La Conditions d’application
surface doit être sèche et exempte de poussières, débris, sels, Humidité relative: ................. jusqu'à 80%
Température de surface: ..... 5 - 40ºC
graisse, ciment et autres contaminants immédiatement avant
recouvrement. Le primaire utilisé doit être appliqué suivant les Steelguard FM 585 doit être appliqué dans des locaux secs, non
instructions spécifiques de la fiche technique et doit être exposés, exempts de forte humidité et de condensation.
approuvé par PPG pour s'assurer de la compatibilité avec le
Steelguard FM 585. Steelguard FM 585 ne doit pas être Pour éviter tout risque de condensation, s'assurer que la
appliqué directement sur substrat recouvert de zinc. température du subjectile est au minimum supérieure de 3°C au
L'épaisseur sèche totale du primaire ne doit pas dépasser 150 point de rosée. Les conditions de séchage optimum sont à des
μm. températures supérieures à 10°C avec une bonne ventilation. Dans
des espaces confinés, il est recommandé d'effectuer une
ventilation adaptée afin d'éviter le retardement du séchage.
Procedure d'application
Steelguard FM 585 ne doit pas être appliqué si un risque de
Une application par pulvérisation apportera une meilleure condensation ou une chute de température est prévisible durant les
finition phases initiales de séchage.
PISTOLET AIRLESS – Utiliser une pompe capable de produire
une pression minimum à la buse de 2800 psi (200 kg/cm²). Un Durée de vie ........................... non applicable
filtre 30 mesh/ 500 μm est recommandé. Buse de 0,43-0,53
mm (0,017 à 0,021 pouces). L'épaisseur sèche de la première Diluant ................................... normalement pas nécessaire
couche ne doit pas dépasser 700µm. Il conviendra d'éviter les Pour diluer, l'eau peut être utilisée si nécessaire jusqu'à 5% en
surépaisseurs, particulièrement à l'intérieur des angles et dans volume.
les coins. Une attention particulière devra Dans ce cas, les mesures des épaisseurs de couche humide en
BROSSE – Appliquer en utilisant une brosse propre et bien seront modifiées et il devra être pris en compte la réduction de
chargée jusqu'à une épaisseur sèche de 300 μm par couche. l'épaisseur du film sec.
En règle générale, permettre un séchage d'au moins 4 heures Nettoyant ................................ Eau douce
à 20°C entre couches.
Recouvrement
Bien qu'il ne soit pas nécessaire de recouvrir le Steelguard 585
pour des environnements C1, il est possible pour des raisons
décoratives d'appliquer les Amercoat 220 qui sont les finitions
en phase aqueuse recommandées.
Steelguard FM 585 devra sécher au minimum 4 heures à 20°C
avant de le recouvrir avec l'Amercoat 220.
Pour plus de détails concernant la compatibilité avec d'autres
finitions comme le Steelguard 2458, merci de contacter votre
représentant PPG. Il est important que l'épaisseur de la couche
intumescente spécifiée soit appliquée avant de recouvrir.
Caractéristiques de séchage
Les temps de séchage varient considérablement en fonction
des conditions ambiantes, de la méthode d'application, du
coefficient de massivité A/V m-1 (Hp/A) et de l'épaisseur du film
appliqué. Par exemple, à 20°C (RH=50%), une couche de 400
μm d'épaisseur sèche sera sèche au toucher en 2 heures
approximativement et sec à cœur après 4 heures environ. Pour
plus de détails sur les temps de séchage du Steelguard FM
585, se référer aux tableaux de séchage ou contacter votre
représentant PPG.
.
Procédure d'application
1. Nettoyer le matériel avec un diluant adéquat, puis rincer Données d'expédition
abondamment à l'eau douce avant utilisation.
Conditionnement .................... 20 litres
2. Homogénéiser le produit et continuer à le brasser jusqu'à
obtention d'un aspect uniforme. La dilution n'est pas Poids brut .............................. environ. 29 kg
requise.
3. Pour une application au pistolet Airless, appliquer un feuil Durée de vie .......................... 1 an à compter de la date
humide en passes égales et parallèles. Chevaucher d'expédition pour un produit stocké
chaque passe à 50% pour éviter les manques, porosités et à l'abri dans son conditionnement
maigreurs. d'origine fermé, à une température
4. Doubler la couche sur les soudures, les aspérités, les comprise entre 5 et 40°C (41 à
arêtes vives et les recoins, les rivets, les boulons, etc. 104°F).
5. L’application d’un feuil humide à 570µm donnera
Doit être protégé du froid.
normalement un feuil sec de 400µm.
6. . Contrôler l’épaisseur du feuil sec avec une jauge
d’épaisseur non destructive de type Microtest ou
Elcometer. Si la mesure est inférieure à l’épaisseur
spécifiée, appliquer un nouveau voile de peinture.
7. Les petites surfaces endommagées, les manques, les
maigreurs, les porosités peuvent être reprises à la brosse.
Les surfaces plus grandes peuvent être reprises à la
brosse, au rouleau ou au pistolet Airless
8. Dans les espaces confinés, assurer une circulation d’air
frais durant l’application et le séchage. Le taux d'humidité
doit être maintenue en dessous de 80%, la température
maintenue de façon à éviter toute condensation sur la
surface pendant application et dans les premières phases
de séchage.
9. Nettoyer tout le matériel avec de l'eau douce et propre
immédiatement après utilisation.
Conditions de vente
Se référer aux conditions de vente particulières.
Fiche Technique/
Instructions d’application Caractéristiques physiques
Aspect du produit sec............. Mat
• Complexe de reparation intumescent solvanté Couleur................................... Blanc
• Application jusqu'à 2 mm d'épaisseur sèche
Composants ........................... 1
par couche
• Rapidité d'exécution Durcissement ......................... évaporation de solvant
Point éclair
(vase clos) ........................... ºC °F
Steelguard FM 550 .............. 26 79
Amercoat 65 ........................ 24 75
Preparation de surface
Supprimer le revêtement intumescent Steelguard FM Instructions d’application
endommagé sur 1 ou 2 centimètres de toutes parts Support................................... Acier revêtu d'un primaire
en formant une arête douce (zone assez large pour (préalablement décapé par
permettre une préparation de surface aisée). projection d'abrasifs)
S'assurer que le subjectile ainsi exposé est proper, Matériel d'application.............. Truelle, couteau à enduire, spatule
sec et exempt de contaminations. Si une couche de
finition a été appliquée, celle-ci sera éliminée par Conditions d'application
Hygrométrie ......................... inférieure à 85%
ponçage léger pour éviter un possible Temperature du support ...... 5 - 40°C (41-104°F)
chevauchement. Lorsque le revêtement intumescent Temperature de l'air............. 5 - 40°C (41-104°F)
Steelguard FM a été directement appliqué sur un
subjectile décapé par projection d'abrasifs,toute La temperature de surface doit être au moins de 3°C au-dessus du
point de rosée.
surface endommagée devra être décapé par
projection d'abrasifs au degree de soin Sa 2 ½ selon Durée de séchage à une épaisseur humide de 2mm à 20°C
la norme ISO 8501-1 ou, lorsque cela n'est pas Sec au toucher..................... 2 heures
Sec manipulable .................. 48 heures
pratique, au degree de soin St2 minimum. Un Durcissement complet ......... 7 jours
primaire PPG approprié devra être appliqué avant
que le degree desoin ne se degrade. Lorsqu'un Les temps de séchage peuvent varier considérablement en
primaire aura été utilise à l'origine, toute surface function de l'épaisseur depose et des conditions ambiantes.
endommagée devra être réparée en respectant la Délais de recouvrement (minimum) à 20°C avec lui-même ou
specification technique d'origine en utilisant un Steelguard 2458
primaire approuvé par PPG. Si Steelguard 2450 est Jusqu'à 0.5 mm secs ........... 6 heures
De 0.5 à 1.0 mm secs.......... 12 heuers
appliqué sur un primaire provenance d'autres De 1.0 à 1.5 mm secs.......... 18 heures
fournisseurs, la compatibilité devra être vérifiée par De 1.5 à 2.0 mm secs.......... 24 heures
votre représentant PPG avant application.
Durée de vie en pot .............. non applicable
Procédure d'application
Appliquer par truelle, couteau à enduire ou à la Données d'expédition
spatule. Le revêtement doit être appliqué légèrement Conditionnement .................... 2.5 litres
fin sur la surface environnante pour permettre une
contraction du produit lors du séchage Poids brut ............................... environ 5 kg
Conditions de vente
Se référer aux conditions de vente particulières.
Fiche Technique/
Instructions d’application Caractéristiques physiques
Aspect du produit sec............. Mat
• Complexe de reparation intumescent solvanté Couleur................................... Blanc
• Application jusqu'à 2 mm d'épaisseur sèche
Composants ........................... 1
par couche
• Rapidité d'exécution Durcissement ......................... évaporation de solvant
0.5 0.79
0.8 1.05
1.0 1.32
1.5 1.97
2.0 2.63
Point éclair
(vase clos) ........................... ºC
Steelguard FM 550 .............. 26
Amercoat 65 ........................ 24
Preparation de surface
Supprimer le revêtement intumescent Steelguard Instructions d’application
endommagé sur 1 ou 2 centimètres de toutes parts Support................................... Acier revêtu d'un primaire
en formant une arête douce (zone assez large pour (préalablement décapé par
permettre une préparation de surface aisée). projection d'abrasifs)
S'assurer que le subjectile ainsi exposé est proper, Matériel d'application.............. Truelle, couteau à enduire, spatule
sec et exempt de contaminations. Si une couche de
finition a été appliquée, celle-ci sera éliminée par Conditions d'application
Hygrométrie ......................... inférieure à 85%
ponçage léger pour éviter un possible Temperature du support ...... 5 - 40°C (41-104°F)
chevauchement. Lorsque le revêtement intumescent Temperature de l'air............. 5 - 40°C (41-104°F)
Steelguard a été directement appliqué sur un
subjectile décapé par projection d'abrasifs,toute La temperature de surface doit être au moins de 3°C au-dessus du
point de rosée.
surface endommagée devra être décapé par
projection d'abrasifs au degree de soin Sa 2 ½ selon Durée de séchage à une épaisseur humide de 2mm à 20°C
la norme ISO 8501-1 ou, lorsque cela n'est pas Sec au toucher..................... 2 heures
Sec manipulable .................. 48 heures
pratique, au degree de soin St2 minimum. Un Durcissement complet ......... 7 jours
primaire PPG approprié tel que Amerlock 2C oo 400C
devra être appliqué avant que le degree desoin ne se Les temps de séchage peuvent varier considérablement en
degrade. Lorsqu'un primaire aura été utilise à function de l'épaisseur depose et des conditions ambiantes.
l'origine, toute surface endommagée devra être Délais de recouvrement (minimum) à 20°C avec lui-même ou
réparée en respectant la specification technique Steelguard 2458
d'origine en utilisant un primaire approuvé par PPG. Jusqu'à 0.5 mm secs ........... 6 heures
De 0.5 à 1.0 mm secs.......... 12 heuers
Si Steelguard 2451 est appliqué sur un primaire De 1.0 à 1.5 mm secs.......... 18 heures
provenance d'autres fournisseurs, la compatibilité De 1.5 à 2.0 mm secs.......... 24 heures
devra être vérifiée par votre représentant PPG avant
application. Durée de vie en pot .............. non applicable
Procédure d'application
Appliquer par truelle, couteau à enduire ou à la Données d'expédition
spatule. Le revêtement doit être appliqué légèrement Conditionnement .................... 2.5 litres
fin sur la surface environnante pour permettre une
contraction du produit lors du séchage Poids brut ............................... environ 5 kg
Conditions de vente
Se référer aux conditions de vente particulières.
Dry film thickness (µm) .......... 250 400 500 700 1000
Approvals Wet film thickness (µm)
Steelguard FM 2570 has been tested to National and 373 597 746 1045 1493
2
International standards for cellulosic fire exposure (ISO Theoretical coverage (m /l) ….
2.68 1.68 1.34 0.96 0.67
834) and subsequently assessed and certified in
(wet film thicknesses quoted are
accordance with various National requirements. Please theoretical for one airless spray
contact your PPG Protective and Marine Coatings coat)
representative for latest information relating to local market
requirements and approvals. For given projects PPG Specific gravity ....................... 1.27 kg/l
Protective and Marine Coatings can provide customers with
Flashpoint
loading data and material consumption calculations
(closed cup) ......................... ºC ºF
stipulated by required fire protection, steel section Steelguard FM 2570 ......... 26 79
designation and local requirements. Standard loading tables Amercoat 12 ..................... 24 75
can be made available where applicable.
APPROVED PRODUCT
CF 542
Application Methods
AIRLESS SPRAY - Use a pump capable of producing a
minimum pressure at the tip of 2800 psi (200 kg/cm²). Tip
size 19-25 thou’ (0.48-0.63mm).
BRUSH – Suitable only for small areas such as repairs.
Apply evenly using a clean, well-loaded brush at up to
300microns dft per coat. Allow at least 4 hours drying at
20ºC/68ºF between coats.
Application Procedure:
1. Flush equipment with recommended cleaner before use. Shipping Data
2. Stir to an even consistency with a power mixer.
Pack size ................................ 20 litres
3. Thinning is normally not required for airless spray.
4. For airless spray apply a wet even coat in parallel Shipping weight ..................... approx. 27 kg (20 l)
passes. Overlap each pass 50% to avoid bare areas,
pinholes or holidays. Shelf life ................................. 12 months when stored indoors in
5. Give special attention to welds, rough spots, sharp unopened, original containers at 5
to 30°C (41 to 86ºF).
edges and corners, rivets, bolts, etc.
6. Application at 600 µm wet film thickness will normally
provide 400 µm dry film.
7. Check thickness of dry coating with a non- destructive
dry film thickness gauge, such as Mikrotest or
Elcometer. If less than specified thickness, apply
additional material as needed.
8. Small damaged or bare areas and random pinholes or
holidays can be touched up by brush. Repair larger
areas either by spray or brush with Steelguard FM 2570.
9. In confined areas ventilate with clean air during
application and drying until all solvents are removed.
Temperature and humidity of ventilating air must be
such that moisture condensation will not form on
surface.
10. Clean all equipment with recommended cleaner
immediately after use or at least at the end of each working
day or shift.
Before using the product, read the label on the can and
consult the material safety data sheet.
Condition of Sale
All our transactions are subject to our Terms and Conditions
of Sale.
Primaires
Amercoat 68E
Amercoat 68G
Amercoat 139
Steelguard 3290
> START
We Know...
Fire Protection
Coatings
Amercoat
Amercoat 68E
Primaire époxy très riche en zinc
Fiche Technique/
Instructions d’application Caractéristiques physiques
Aspect ................................... Mat
• 85% minimum de zinc en poids dans le film sec Couleur .................................. gris rouge
• Combine la dureté de l'époxy avec la
Nombre de composants ........ 2
protection supérieure du zinc
• Résistance exceptionnelle aux intempéries Proportion du mélange (en volume)
• Performances supérieures en milieu industriel résine ................................... 4 parts
durcisseur ........................... 1 part
et naval
• Application facile au pistolet airless ou
conventionnel Durcissement ........................ par dégagement de solvant et
réaction entre les composants
Principales utilisations
Extrait sec en volume ............ 57% (ISO 3233)*
Recouvert par des systèmes de finition adaptés,
l’Amercoat 68E peut être utilisé pour les applications Composants organiques volatils ( COV )**
suivantes. EC SED 1999/13/EC ........... 148 g/kg (410 g/l)
INDUSTRIE - Constructions en acier, tuyauteries et UK PG6/23(92) Appendix 3 . 363 g/l (3.0 lbs/gal)
extérieurs de réservoirs, dans les papeteries, les Épaisseur du film sec ............ 50-75 µm (2-3 mils)
raffineries de pétrole, les centrales électriques,
l’industrie chimique et les installations de traitement Nombre de couche ................ 1
de déchets. Pouvoir couvrant ................... 7,6 m²/ l (pour un film de 75 µm)
INSTALLATIONS MARITIMES - Ponts, coques et 2
309,6 ft /gal (à 3 mils)
superstructures de navires, de barges et de
remorqueurs. Appontements, plates-formes en mer et Tenir compte des pertes dues à l’application, aux surépaisseurs,
constructions annexes aux irrégularités de surface, etc.
Masse volumique du
Caractéristiques exceptionnelles mélange ................................. 2,8 kg/l
L’Amercoat 68E est un primaire riche en zinc, à liant
époxy, bi-composants, à haute teneur en zinc. Cette Résistance à la température . 205°C/400°F chaleur sèche
haute teneur en zinc, procure une excellente Point éclair (vase clos) ........... °C
protection cathodique et une grande résistance à la résine .................................. 23
corrosion, même lorsque le film est endommagé. durcisseur ........................... 18
Utilisé en tant que primaire d’un système de peinture, Amercoat 9HF ..................... 26
l’Am 68 E procure des performances supérieures, Diluant/nettoyant ................... Amercoat 9HF
dans une large gamme d’environnements hautement
corrosifs. Recouvert par des finitions adaptées, il
résiste aux éclaboussures et coulures, d’eau, de * L’extrait sec en volume est mesuré suivant la norme ISO 3233.
solvants, de produits chimiques et pétroliers. Des variations de ± 3% peuvent se produire, imputables à des
différences de couleur et d’essai.
Caractéristiques générales ** COV : les valeurs indiquées pour la directive EC 1999/13 sont
Conforme aux exigences de composition des normes des valeurs théoriques calculées et celles indiquées pour le
SSPC Paint 20, ISO 12944 section 5, BS 4652 et document UK PG6/23(92) Appendix 3 sont des valeurs pratiques
mesurées
BS5493.
L’Amercoat 68E est également conforme aux
exigences de composition des principales sociétés
pétrolières telles que Total/Elf/Fina, ADMA/OPCO et
Aramco APCS 1C & 1F ainsi qu'aux spécifications
des Chemins de fer allemands DB-TL 918300 feuille
87.
Fiche Technique/
Instructions d’application Caractéristiques physiques
Aspect ................................... Mat
• Forte teneur en zinc dans le film sec Couleur .................................. gris rougeâtre
• Allie la dureté de l'époxy avec la protection
Nombre de composants ........ 2
supérieure du zinc
• Résistance exceptionnelle aux intempéries Proportion du mélange (en volume)
• Performances supérieures en milieu industriel Résine.................................. 4 parts
Durcisseur ........................... 1 part
et naval
• Facile à appliquer au pistolet airless ou Durcissement ......................... par dégagement des solvants et
conventionnel réaction entre les composants
Procédure d’application
Le conditionnement de l’Amercoat 68G comprend les Données d'expédition
proportions exactes de résine et de durcisseur devant Conditionnement
être mélangées avant utilisation. résine ............................. 8 l (2,1 gal) en bidon de 10 l
durcisseur ...................... 2l (0,53 gal) en bidon de 2,5 l
Résine: 8 l (2,1 gal) en bidon de 10 l
Durcisseur: 2 l (0,53 gal) en bidon de 2,5 l Poids brut
résine ............................. environ 26 kg
durcisseur ...................... environ 1,9 kg
1. Rincer le matériel avec de l’Amercoat 9HF avant
utilisation. Durée de vie ..................... 1 an à compter de la date
2. Homogénéiser la résine (dans le bidon) à l'aide d'un d’expédition pour un produit
malaxeur mécanique. stocké à l’intérieur dans son
3. Ajouter le durcisseur à la résine et continuer à mélanger conditionnement d’origine
durant 5 minutes. Tamiser à 250 µm (60 mesh) pour fermé, à une température
éviter le risque de bouchage du matériel. REMARQUE : comprise entre 5 et 40°C (41-
La durée de vie du produit étant limitée et réduite à 104°F).
haute température, ne pas mélanger plus de produit
qu'il n'est nécessaire pour une durée de 8 heures à
20°C/68°F.
4. Normalement, il n’est pas nécessaire de diluer pour
l'application airless. Pour l’application au pistolet
conventionnel, diluer uniquement si cela est nécessaire
pour obtenir une bonne pulvérisation, et avec 10%
maximum en volume d’Amercoat 9 HF.
5. Continuer à malaxer pendant l’application afin de
conserver l’homogénéité du produit. Appliquer un film
humide en passes égales et parallèles. Chevaucher à
50 % chaque passe pour éviter les manques, porosités
et maigreurs.
6. Appliquer une pré touche sur toutes les soudures, les
aspérités, les arrêtes et angles vifs, les rivets, les
boulons, etc.
7. L’application d'un film humide de 120 µm (4,8 mils)
donnera normalement un film sec de 75 µm (3 mils).
Eviter les épaisseurs excessives, qui peuvent provoquer
des faiblesses dans le film en cas de recouvrement..
8. Contrôler l'épaisseur du film sec avec une jauge
d'épaisseur non destructive de type Mikrotest ou
Elcomètre. Si la mesure est inférieure à l’épaisseur
spécifiée, appliquer de nouveau un peu de peinture.
9. Les petits défauts, tels que manques, porosités ou
maigreurs, peuvent se corriger à la brosse. Réparer les
zones plus importantes à l'aide d'un pistolet.
10. Dans les espaces confinés, assurer une circulation d'air
frais durant l'application et le séchage, jusqu'à ce que
toutes les vapeurs de solvant aient disparu. La
température et l’humidité de l’air de ventilation doivent
être contrôlées de façon à éviter la formation de
condensation et d’humidité sur la surface.
11. Nettoyer tout le matériel avec de l’Amercoat 9HF
immédiatement après utilisation ou au moins à la fin de
chaque journée de travail ou d’équipe. S'il reste dans le
matériel de pulvérisation, l’Amercoat 68G risque de
sécher et de boucher les circuits.
Fiche Technique/
Instructions d’application Caractéristiques physiques
Aspect ................................... mat
• Primaire d'atelier soudable, applicable au pistolet Couleur .................................. rouge oxyde et gris
pneumatique ou à l'airless
• Manutention presque immédiate après application Nombre de composants ........ 2
• Applicable au pistolet automatique Proportions du mélange
• Peut être recouvert avec une très large gamme de résine .................................. 1 part
revêtements de finition durcisseur ........................... 1 part
• Mélange facile 1 : 1 Durcissement ........................ par évaporation des solvants et par
• Ne contient pas de chromate ni de plomb réaction chimique entre
• Satisfait aux recommandations de l'EPA pour le composants
Royaume Uni, en tant que primaire pour surfaces
Extrait sec volumique ............ 25% (ASTM D2697, modifié)*
décapées à l'abrasif
Composants organiques volatils ( COV )**
EC SED 1999/13/EC ........... 598 g/kg (651 g/l)
Caractéristiques Principales UK PG6/23(92) Appendix 3 . 646 g/l
Amercoat 139 est un époxy bi-composants, à séchage
rapide, possèdant d'excellentes propriétés anti-corrosives Epaisseur du film sec ............ 15-25 µm
pendant la construction. Amercoat 139 est un primaire très Nombre de couches .............. 1
adhérent qui s'applique sur acier grenaillé. Applicable au
2
pistolet pneumatique ou à l'airless. Pouvoir couvrant théorique ... 12.5 m /l à 20 µm
- Primaire soudable, à séchage rapide, aux propriétés
anti corrosives. Prévoir des pertes dues à l'application et aux irrégulatités de
surface
- Epoxy bi-composants, à base de zinc phosphate et de
pigments d'oxyde de fer Masse volumique du mélange 1,13 kg / l
- D'une très grande adhérence sur acier grenaillé Point éclair (coupe fermée)
- Permet une protection de 6 mois dans les ............................................. ºC ºF
environnements industriels moyens, à l'épaisseur de 15 Amercoat 139 ..................... 4 39
à 25 µm. Amercoat 18 ....................... 25 77
- Applicable à l'airless, ou au pistolet pneumatique en Amercoat 12 ....................... 24 75
ligne automatique ou manuellement . * L'extrait sec en volume est mesuré suivant la norme ASTM
- Permet de découper et de souder les tôles et profilés en D2697 modifié. De légers écarts (± 3%) peuvent apparaître en
acier manuellement ou mécaniquement. fonction des couleurs et de l'erreur de mesure.
Instructions d’application
Agréments et Certificats Surface .................................. acier grenaillé
Amercoat 139 est conforme au standard Lloyds Register's Rules
comme primaire de préconstruction pour surfaces marines. Mode d'application ................ airless, pneumatique
Amercoat 139 est conforme aux normes de santé et de sécurité de
Newcastle Occupational Health Agency concernant les opérations Conditions d'Application
de soudage ou oxy-coupage. (pendant l'application)
Approuvé par le Russian Maritime Register of Shipping. Température de l'air............. 5 à 50°C 41 à 122°F
Certificates disponible sous demande. Température du support ...... 5 à 60°C 41 à 140°F
Procédures d'Application
Amercoat 139, est livré dans deux emballages aux Données d'expédition
proportions exactes de résine et de durcisseur.
Emballage
Résine: 10 l en bidon de 20 l résine .................................. 10 l en bidon de 20 l
Durcisseur: 10 l en bidon de 10 l durcisseur ........................... 10 l en bidon de 10 l
1. Avant utilisation, rincer le matériel d'application
avecsolvant de nettoyage Amercoat 12. Poids brut
2. Homogénéiser chaque composant à l'aide d'un résine .................................. approx. 15 kg
malaxeur mécanique. durcisseur ........................... approx. 10 kg
3. Verser le durcisseur dans la résine et continuer à Durée de vie .......................... 1 an à partir de la date de
malaxer pendant 5 minutes. NOTE: Etant donné que la fabricage si stocké sous abri à
durée de vie du mélange est limitée, ne mélanger que la température entre 5 et 40°C (41 et
quantité de produit applicable en 16 heures à 20°C. 104°F).
4. Pour l'application au pistolet pneumatique, diluer si
nécessaire avec 10 % maximum d'Amercoat 14.
5. Maintenir le malaxage pendant l'application pour que le
produit reste homogène. Appliquer un film humide en
passes égales et parallèles. Chevaucher à 50 % chaque
passe afin d'éviter les manques, porosités et maigreurs.
6. Prétoucher les soudures, les angles vifs, les recoins, les
rivets, boulons etc.
7. L'application d'un film humide de 80 µm, donnera
normalement un film sec de 20 µm.
8. Contrôler l'épaisseur du film sec à l'aide d'un appareil de
mesure non destructif, tel que Microtest ou Elcomètre.
S'il y a des sous-épaisseurs, appliquer une couche
complémentaire.
9. Les petites surfaces endommagées, les manques, les
maigreurs, les porosités peuvent être reprises à la
brosse. Les surfaces plus grandes doivent être
repeintes au pistolet.
10. Dans les espaces confinés; il faut maintenir une
ventilation d'air frais pendant l'application et le séchage
jusqu'à ce que tous les solvants soient évaporés. La
température et l'humidité de l'air de ventilation doivent
être telles qu'elles n'entraînent pas de condensation sur
le support à peindre.
11. Après application, rincer le matériel avec Amercoat 12
et ceci au moins une fois à la fin de la journée ou du
poste de travail. Si de l'Amercoat 139 reste dans le
matériel d'application, il va durcir et l'endommager.
Product Data/
Application Instructions Physical Data
Finish ..................................... low sheen
• Rapid drying two pack epoxy zinc phosphate Colour .................................... red oxide, light grey, grey, buff and
primer off white.
• EPA compliant (1998) in accordance with Components .......................... 2
PG6/23
• High build, high solids and low VOC Mixing ratio (by volume)
resin .................................... 6.2 parts
• Corrosion inhibiting cure ..................................... 1 part
• Excellent adhesion to blast cleaned steel
• Excellent abrasion and impact resistance Curing mechanism ................ solvent release and reaction
between components. Effective
• No maximum overcoating restrictions cure down to 5°C/41ºF
Flash points
(Closed Cup)........................ ºC ºF
resin .................................... 24 75
cure ..................................... 24 75
Amercoat 18 ....................... 25 77
Amercoat 12 cleaner............ 24 75
Surface preparation
Surfaces must firstly be thoroughly cleaned of all Application Data
contaminants such as dust, dirt, oil, grease and salts. Substrate ............................... blasted steel
Then abrasive blast clean to ISO 8501-1, Sa21/2. The
blast profile achieved should be within the range 50 to Application methods .............. airless spray, brush or roller
100 microns. Priming should occur before Potlife (at 20°C/68ºF) ............ 2 hours
degradation of the surface takes place. If oxidation
occurs then the surface should be re-prepared. The Induction time (at 20°C/68ºF) not applicable
surface must be dry and free of dust, salts, grease Environmental conditions
and other contaminants immediately before coating.
Steelguard 3290 should only be applied within the limits of
temperature and humidity set out below.
Mixing Relative humidity: ................ Up to 90%
Surface temperature: ........... Minimum 2°C/36ºF
Stir the resin component thoroughly, then add the ............................................. Maximum 40°C/104ºF
cure and continue mixing until the product is uniform
throughout. A powerful mixer should be used. The surface temperature must also be at least 3°C/5ºF above the
dew point during application.
As with most coatings early contact with water can result in water
Application spotting damage. Care should be taken to protect the coating
AIRLESS SPRAY: Use standard airless spray during the early stages of cure to prevent water marking.
equipment capable of producing a minimum pressure
at the tip of 2800 psi (200 kg/cm²). Tip size range 15- Drying characteristics ºC/ºF
21 thou (0.38-0.53mm). Adjustments to pressure and Temperature 5/41 10/50 20/68
tip size/angle may be necessary to obtain spray
characteristics required for specific substrate Touch dry 4 hours 2 hours 1 hours
configurations.
BRUSH/ROLLER: Application by these methods Hard dry 8 hours 5 hours
1
2 /2 hours
should be limited to small areas only such as repairs
and when stripe coating. Apply evenly using a clean, Overcoating 1
8 hours 5 hours 2 /2 hours
(minimum)
well-loaded brush or roller. With this application more
Overcoating - - -
than one coat may be necessary to achieve the (maximum)
required dry film thickness
This product will cure down to 0°C/32ºF, however drying
times will be extended.
Application procedure
1. Clean the equipment with the recommended cleaning Shipping Data
solvent before use.
Packaging............................... 20 litres in two part units
2. Stir the resin component thoroughly, then add the cure resin .................................... 17.23 l in 20 l can
and continue mixing until the product is uniform cure ..................................... 2.77 l in 5 l can
throughout. A powerful mixer should be used. Thinning
is not required. Shipping weight (approx)
3. For airless spray, apply a wet even coat in parallel resin .................................... . 31 kg
passes. Overlap each pass by 50% to avoid bare areas, cure ..................................... 4 kg
pinholes or holidays. Shelf life ................................. 1 year from shipment date or as
4. Give special attention to welds, rough spots, sharp indicated on label when stored
edges and corners, rivets, bolts, etc. indoors in unopened, original
5. Application at 104µm wet film thickness will normally containers at 5 to 40°C (41 to
provide 75µm dry film. 104ºF).
6. Check thickness of dry coating with a non-destructive
dry film thickness gauge, such as Mikrotest or
Elcometer. If less than specified thickness, apply
additional material as needed.
7. Small damaged or bare areas and random pinholes or
holidays can be touched up by brush. Repair larger
areas either by spray, brush or roller using Steelguard
3290.
8. In confined areas ventilate with clean air during
application and drying. The humidity should be
maintained below 90% and the temperature such that
moisture condensation will not form on the surface.
9. Clean all equipment with fresh, clean solvent
immediately after use.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Peintures de finition
Amercoat 220G
Amercoat 220 LS
Amercoat 450E
Amercoat 2136
Steelguard 2458
Amercoat 4310
PSX 700
> START
We Know...
Fire Protection
Coatings
Amercoat
Amercoat 220G
Peinture de finition acrylique à l'eau
Fiche Technique/
Instructions d’application Caractéristiques physiques
Aspect .................................. brillant
• Peinture de finition monocomposant acrylique Couleur .................................. RAL et BS*
à l'eau
Composants ........................... 1
• Conforme à la norme EPA (1998)
• Faible teneur en composants organiques Extrait sec en volume ............ 40 ± 2%
volatils
Composants organiques volatils ( COV )**
• Faible odeur EC SED 1999/13/EC ........... 41 g/kg (50 g/l)
• Non inflammable UK PG6/23(92) Appendix 3 . 140 g/l
• Bonne tenue de la couleur et de la brillance
Durcissement ......................... séchage physique
• Compatible avec la plupart des revêtements
existants type minimum maximum
Principales utilisations (Les épaisseurs de film humide indiquées sont les épaisseurs
théoriques pour une couche appliquée au pistolet airless).
Peinture de finition de longue durée à l'eau pour toits
de réservoirs et protections externes, structures Pouvoir couvrant théorique ... 10,0 m²/l (pour épaisseur type)
industrielles en général et charpentes en acier,
Masse volumique ................... approx. 1,05 – 1,25 kg/l (en
mobilier d'extérieur et réverbères. Adaptée pour les fonction de la couleur).
applications dans les zones d'entrepôt, les écoles, les
hôpitaux, les laboratoires et autres zones internes où Point éclair (vase clos) ........... non applicable
l'utilisation de revêtements à base de solvant est * Se reporter aux recueils de couleurs de bas RAL et BS-4800.
limitée pour des raisons de santé, de sécurité, ou de
protection de l'environnement. ** COV : les valeurs indiquées pour la directive EC 1999/13 sont
des valeurs théoriques calculées et celles indiquées pour le
document UK PG6/23(92) Appendix 3 sont des valeurs pratiques
mesurées.
Procédure d’application
1. Rincer l’équipement avant utilisation avec le Données d'expédition
diluant recommandé. Conditionnement .............. 5 litres
2. Agiter le contenu du bidon pour l'homogénéiser.
Pas de dilution nécessaire normalement pour Poids brut .......................... environ 7 kg
l'application airless.
Durée de vie ..................... 1 an à compter de la date
3. Malaxer pendant l’application afin de conserver d’expédition ou selon
l’homogénéité du produit. l’indication de l'étiquette, pour
4. Lors de l'application au pistolet, appliquer un film un produit stocké à l’abri dans
humide en passes égales et parallèles. le conditionnement d’origine
Chevaucher à 50% chaque passe pour éviter les fermé à une température entre
manques, porosités et maigreurs. 5 et 40°C (41 et 40ºF).
5. Appliquer une double couche sur tous les endroits
rugueux, les arrêtes et cornières, les rivets,
boulons, etc.
6. L’application d’un film humide de 100 µm produira
normalement un film sec de 40 µm.
7. Contrôler l’épaisseur du film sec avec une jauge
d’épaisseur non destructive de type Mikrotest ou
Elcomètre. Si la mesure est inférieure à
l’épaisseur spécifiée, appliquer encore un peu de
peinture.
8. Les petits défauts, les manques et les porosités ou
maigreurs peuvent se corriger à la brosse.
Réparer les zones plus importantes à l’aide d’un
pistolet.
9. Dans les espaces confinés, assurer une circulation
d’air frais durant l’application et le séchage jusqu’à
ce que toutes les vapeurs aient disparu. La
température et l’humidité de l’air de ventilation
doivent être choisies de façon à éviter la formation
de condensation et d’humidité sur la surface.
10. Nettoyer tout le matériel avec le nettoyant
recommandé , immédiatement après utilisation ou
au moins à la fin de chaque journée de travail ou
changement d’équipe.
Conditions de vente
Se référer aux conditions de vente particulières.
Réparation
Les zones mises à nu doivent être nettoyées par décapage
à l’abrasif ou par décapage mécanique suivant §
préparation de surface, et doivent être recouvertes d’un
primaire conformément à la spécification initiale. Poncer les
arêtes crées au droit des anciens fonds en bon état.
Éliminer la poussière, les impuretés et tout autre
contaminant avant le recouvrement.
Conditions de vente
Se référer aux conditions de vente particulières.
Procédure d’application
Amercoat 450E est conditionné dans les proportions Données d'expédition
exactes de résine et de durcisseur qui doivent être Conditionnement
mélangées avant utilisation. Résine............................. 16 l en bidons de 20 l
Durcisseur....................... 4 l en bidons de 5 l
1. Avant utilisation, rincez le matériel d'application avec le
solvant de nettoyage recommandé. Poids brut (pour 20 litres) kg lb
2. Homogénéisez la résine et le durcisseur à l’aide d’un Résine............................. 25 55
malaxeur mécanique. Durcisseur....................... 5 11
3. Verser le durcisseur dans la résine et continuez à
mélanger pendant 5 minutes. NOTE : étant donné que Durée de vie
la durée de vie du mélange est limitée et réduite à haute Résine et durcisseur.......... 1 an à compter de la date
température, prendre soin de ne mélanger que la d’expédition pour un produit
quantité de produit nécessaire à vos besoins en fonction stocké en intérieur dans son
de la durée de vie du mélange à température ambiante. conditionnement d’origine
4. Pour l’application par pulvérisation, diluez uniquement si fermé, à une température
nécessaire pour l'atomisation du produit, sans dépasser comprise entre 5 et 40°C (41-
10 % en volume d'Amercoat 920. Pour l’application à 104°F)
des températures inférieures à 10°C/50°F, ajouter du
diluant pour obtenir une pulvérisation correcte.
REMARQUE : en principe, l’application à la brosse et au
rouleau ne nécessite pas de dilution.
5. Appliquez un film humide en passes égales et
parallèles. Chevauchez à 50 % chaque passe pour
éviter les manques, porosités et maigreurs.
6. Appliquer des prétouches à la brosse sur toutes les
soudures, les aspérités, les arêtes vives et angles, les
rivets, les boulons, etc.
7. L’application d'un film humide de 83 µm donnera
normalement un film sec de 50 µm (2 mils) .
8. Contrôler l’épaisseur du film sec à l'aide d'un appareil de
mesure non-destructif, tel que Mikrotest ou Elcomètre.
S'il y a des sous épaisseurs, appliquer une couche
complémentaire
9. Les petits défauts, tels que manques, porosités ou
maigreurs, peuvent être reprises à la brosse. Réparer
les zones plus importantes par pulvérisation.
10. Dans les espaces confinés, assurez une circulation d’air
frais durant l’application et le séchage, jusqu’à ce que
tous les solvants soient évaporés. La température et
l’humidité de l’air de ventilation doivent être contrôlées
de façon à éviter la formation de condensation sur la
surface.
11. Nettoyez le matériel avec le nettoyant recommandé
Amercoat 12 immédiatement après utilisation, ou au
moins à la fin de chaque journée de travail ou à chaque
poste. Si le produit mélangé est laissé dans le circuit de
pulvérisation, le produit réticulera et entraînera de
nombreux bouchages à la sortie de la buse
Réparation
En cas de réparation ou pour une épaisseur
complémentaire, Amercoat 450E peut être
surcouché par lui-même sans délai de recouvrement
maximum. S'assurer que la surface est propre avant
l'application.
Conditions de vente
Se référer aux conditions de vente particulières.
Fiche Technique/
Instructions d’application Caractéristiques physiques
Aspect du produit sec............. faiblement brillant, aspect
métallique lustré
• Système pratique de finition , mono couche ,
épais Couleur .................................. noir, gris moyen, gris argenté, gris
• Adhére directement sur l'acier galvanisé clair argenté
• Gamme d'utilisations étendue Composant ............................. 1
• Produit monocomposant
Durcissement ......................... Par évaporation des solvants
• Compatible avec la plupart des revêtements
anciens Extrait sec en volume ............ 53±2%
• Pas de contrainte de surcouchage /
Composants organiques volatils ( COV )*
recouvrement EC SED 1999/13/EC ........... 304 g/kg (484 g/l)
UK PG6/23(92) Appendix 3 . 490 g/l
Mélange
Agiter longuement avant l'utilisation jusqu'à obtenir un
mélange homogéne.
•
Matériel d’application
Les matériels sont indiqués à titre d’exemple ; tout autre
matériel adapté est également utilisable. Ajuster la pression
et la dimension des buses pour obtenir une pulvérisation
correcte.
BROSSE/ROULEAU – Appliquer de façon uniforme à l'aide
d'une brosse ou d'un rouleau propre et bien chargé. Ne pas
tenter d'essuyer ou de repasser sur une couche non sèche.
PISTOLET AIRLESS - Diluer si nécessaire au
maximum avec 10% du diluant recommandé. Taille
de buse 15-18 (0,38 - 0,46mm) Pression à la buse :
200 kg/cm².
Méthodes d’application
1. Rincer l’équipement avant utilisation avec le diluant Données d'expédition
recommandé.
Conditionnement ............... 5 litres (1.32 gal)
2. Homogénéiser le contenu du bidon à l’aide d’un
malaxeur mécanique. Poids brut .......................... environ 8,5 kg
3. Normalement il n’est pas nécessaire de diluer pour
l’application airless. Durée de vie ..................... 1 an pour un produit stocké
Pour l’application au pistolet conventionnel, diluer dans un endroit clos et dans
uniquement si nécessaire, au maximum avec 10% de son conditionnement d'origine
diluant. fermé, à température comprise
4. Continuer à malaxer pendant l’application afin de entre 5 et 40°C (41-104°F).
conserver l’homogénéité du produit. Appliquer un film
humide en passes égales et parallèles. Chevaucher à
50% chaque passe pour éviter les manques, porosités
et maigreurs.
5. Appliquer une prétouche sur toutes les soudures, les
aspérités, les arrêtes et angles vifs, les rivets, boulons,
etc.
6. L’application d’un film humide de 142 µm (5.7 mils)
produira normalement un film sec de 75 µm (3 mils).
7. Contrôler l’épaisseur du film sec avec une jauge
d’épaisseur non destructive de type Mikrotest ou
Elcomètre. Si la mesure est inférieure à l’épaisseur
spécifiée, appliquer encore un peu de peinture.
8. Les petits défauts, tels que les manques, porosités et
maigreurs, peuvent se réparer à la brosse. Réparer les
surfaces plus importantes à l’aide du pistolet
9. Dans les espaces confinés, assurer une circulation d’air
frais durant l’application et le séchage jusqu’à ce que
toutes les vapeurs de solvant aient disparu. La
température et l’humidité de l’air de ventilation doivent
être contrôlées de façon à éviter la formation de
condensation et d’humidité sur la surface.
10. Nettoyer le matériel à l’eau immédiatement après
utilisation ou au moins à la fin de chaque journée de
travail ou à chaque changement d’équipe.
Conditions de vente
Se référer aux conditions de vente particulières.
Fiche Technique/
Instructions d’application Caractéristiques physiques
Aspect du produit sec ............ semi-brillant
• Conforme aux normes EPA (1998) comme Couleur .................................. couleurs RAL et BS*
finition pour peintures intumescentes
Steelguard FM Composants ........................... 1
Point éclair
(vase clos) ........................... ºC ºF
Steelguard 2458 .................. 24 77
Amercoat 65 ........................ 24 77
Procédure d’application :
1. Rincer l’équipement avec le diluant recommandé Données d'expédition
avant utilisation. Conditionnement .............. 20 litres
2. Homogénéiser à l’aide d’un malaxeur mécanique.
3. Pas de dilution nécessaire normalement pour Poids brut ......................... environ 28 kg
l'application airless
Durée de vie ..................... 1 an en stockage dans un
4. Malaxer pendant l’application afin de conserver endroit clos et dans son
l’homogénéité du produit conditionnement fermé
Appliquer un film humide en passes égales et d'origine, à température
parallèles. Chevaucher à 50% chaque passe pour comprise entre 5 et 40°C (41-
éviter les manques, porosités et maigreurs. 104°F).
5. Appliquer une double couche sur tous les
endroits rugueux, les arrêtes et cornières, les
rivets, boulons, etc.
6. L’application d’un film humide de 167 µm produira
normalement un film sec de 75 µm.
7. Contrôler l’épaisseur du film sec avec une jauge
d’épaisseur non destructive de type Mikrotest ou
Elcomètre. Si la mesure est inférieure à
l’épaisseur spécifiée, appliquer encore un peu de
peinture.
8. De légères détériorations, des zones nues et des
porosités ou maigreurs peuvent se corriger à la
brosse. Réparer les zones plus importantes à
l’aide d’un pistolet.
9. Dans des espaces confinés, assurer une
circulation d’air frais durant l’application et le
séchage jusqu’à ce que toutes les vapeurs de
solvant aient disparu. La température et l’humidité
de l’air de ventilation doivent être contrôlées de
façon à éviter la formation de condensation et
d’humidité sur la surface.
10. Nettoyer tout le matériel avec le nettoyant
recommandé immédiatement après utilisation ou
au moins à la fin de chaque journée de travail ou
changement d'équipe.
Conditions de vente
Se référer aux conditions de vente particulières.
Mixing
Stir thoroughly before use until the product is uniform
throughout.
Application Methods
AIRLESS SPRAY: Use standard airless spray Application Data
equipment capable of producing a minimum pressure Substrate ................................ Primed substrates
at the tip of 2800 psi (200 kg/cm²). Tip size range 13-
17 thou (0.33-0.43mm). Adjustments to pressure and Application methods ............... airless or conventional spray, brush
or roller
tip size/angle may be necessary to obtain spray
characteristics required for specific substrate Potlife (at 20°C/68ºF) ............ N/A
configurations.
Environmental Conditions
CONVENTIONAL SPRAY: Use standard industrial Amercoat 4310 should only be applied within the limits of
equipment. Thinning with the recommended thinner temperature and humidity set out below.
may be necessary to facilitate application. Relative humidity: ................ up to 90%
BRUSH/ROLLER: Apply evenly using a clean, well- Surface temperature: ........... minimum: 5°C/41ºF
............................................. maximum: 40°C/104ºF
loaded brush or roller. With this application more than
one coat may be necessary to achieve the required dry The surface temperature must also be at least 3°C/5ºF above dew
film thickness. point.
NOTE: drying and curing times are dependent on air and steel
temperature, applied film thickness, ventilation and other
environmental conditions. Times are shorter at higher temperatures
and longer at lower temperatures
Application procedure
1. Flush equipment with recommended cleaner Shipping Data
before use. Pack size ............................... 5 litres
2. Stir the contents of the can to an even
consistency. Shipping weight ...................... approx. 6 kg
3. Thinning is normally not required for airless spray. Shelf life ................................. 1 year from shipment date or as
4. Stir during application to maintain uniformity of indicated on label when stored
material. Apply a wet even coat in parallel passes. indoors in unopened, original
containers at 5 to 40°C (41 to
Overlap each pass 50% to avoid bare areas, 104ºF).
pinholes or holidays.
5. Double coat all rough spots, sharp edges and
corners, rivets, bolts, etc.
6. Application at 85 µm wet film thickness will
normally provide 40 µm dry film.
7. Check thickness of dry coating with a non-
destructive dry film thickness gauge, such as
Mikrotest or Elcometer. If less than specified
thickness, apply additional material as needed.
8. Small damaged or bare areas and random
pinholes or holidays can be touched up by brush.
Repair larger areas by spray.
9. In confined areas ventilate with clean air during
application and drying until all solvents are
removed. Temperature and humidity of ventilating
air must be such that moisture condensation will
not form on surface.
10.Clean all equipment with recommended cleaner
immediately after use or at least at the end of each
working day or shift
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Instructions d’application
Caractéristiques physiques
Aspect ................................... brillant
• Le PSX 700, permet d'obtenir des performances
uniques, notamment une brillance élevée et stable Couleur .................................. couleurs RAL et BS*
• Peut être appliqué directement sur un zinc Nombre de composants ........ 2.
inorganique ( sans tie coat )
• Brillance et stabilité de couleur dépassant le Proportions du mélange (en volume)
meilleur des polyuréthanes PSX 700 base ..................... 4 parts
PSX 700 FD durcisseur ...... 1 part
• Coût d'application considérablement réduit
• Excellente résistance à la corrosion Séchage ............ .................... réaction chimique entre les
• Très haut extrait sec, COV faibles composants
• Application sans diluant à la brosse, au rouleau ou Extrait sec en volume ............ 90% (ISO 3233) **
au pistolet
• Bonne résistance aux éclaboussures et coulures de Composants organiques volatils ( COV )***
produits chimiques EC SED 1999/13/EC ........... 88 g/kg (120 g/l)
UK PG6/23(92) Appendix 3 . 120 g/l (1.0 lbs/gal)
Préparation de Surface
D'une façon générale, il est admis que les performances d'un
revêtement sont directement liées au degré de préparation de surface,
et que le décapage à l'abrasif est la méthode la plus efficace et la plus
économique. Avant l'application, la surface à peindre doit être propre et
séche.
BETON - La surface doit être dure, sèche et exempte de poussière,
huile minérale, souillure, graisse, revêtement non adhérent et autres
impuretés. Décaper le béton neuf conformément aux normes ASTM
D4259.
ALUMINIUM - Eliminer huile, graisses et autres impuretés avec un
détergent neutre ou un nettoyant émulsifiant, traiter la surface avec de
l’Alodine 1200, ou de l’Alumiprep ou un produit équivalent ou balayer à
l’abrasif.
SURFACES DEJA PEINTES - S'assurer que celles-ci sont propres,
sans graisse, poussière, boue ou autre contaminant. Il est recommandé
d'effectuer un test de compatibilité sur des fonds d'origine inconnue.
Consulter PPG pour des recommandations spécifiques.
Séchage accéléré
Le PSX 700 doit être sec au toucher avant d'être exposé à des
températures supérieures à 60°C/104ºF.
Procédure d'Application
Le PSX 700 est livré avec les quantités exactes de base et
durcisseur pour le mélange.
PSX 700 base: 16 l ou 4l en bidon de 20 ou 4 litres
PSX 700 FD durcisseur 4 l ou 1 l en bidon de 5 ou 1 litre
1. Avant utilisation rincer le matériel avec le solvant de nettoyage
Amercoat 12.
2. Homogénéiser chaque composant à l'aide d'un malaxeur
mécanique.
3. Verser le durcisseur dans la résine et continuer à malaxer
jusqu'à complète homogénéisation.
4. Diluer si nécessaire sans dépasser 10% en volume d'Amercoat
911.
5. Appliquer un film humide en passes égales et parallèles.
Chevaucher à 50 % chaque passe afin d'éviter les manques,
porosités et maigreurs. Prêter une attention particulière aux
angles, cordons de soudure, arêtes et endroits critiques.
6. L'application à la brosse ou au rouleau nécessitera deux
couches pour atteindre les 125 µm recommandés.
7. Lorsque PSX 700 est appliqué directement sur un Dimetcote, il
est recommandé d'utiliser la technique du mist coat – full coat
(couche brouillard/couche couvrante ) pour minimiser les
risques de cloquage. Diluer le PSX 700 au maximum à 10% en
volume avec de l'Amercoat 900 pour obtenir l'épaisseur de
couche souhaitée et pour éviter le cloquage. Ceci dépend de
l'âge du revêtement, de la rugosité de la surface et des
conditions ambiantes pendant le durcissement.
8. Après l'application, rincer le matériel avec le solvant de
nettoyage spécifié et ce au moins une fois à la fin de la journée
ou du poste de travail. Si la peinture est laissée dans les
tuyauteries et le matériel d'application, on s'expose à une prise
en masse totale ou partielle, entraînant soit de nombreux
bouchages à la reprise du travail, soit à un blocage complet du
matériel.
Language Selection
Russian
We Know...
Fire Protection
Coatings
PROFESSIONALS IN PROTECTION
> START
We Know...
Fire Protection
Coatings
PROFESSIONALS IN PROTECTION
ɐɟɦɟɧɬɢɪɭɸɳɢɟɩɨɤɪɵɬɢɹ
Steelguard CM 4701
Steelguard CM 4702
Steelguard CM 4703
Steelguard CM 4704
Steelguard CM 4705
Steelguard CM 4706
> START
We Know...
Fire Protection
Coatings
Amercoat
Steelguard CM 4701
Spray Applied Fire Resistant Tunnel Coating
Product Data/
Application Instructions Physical Data
Appearance ............................ sprayed textured finish, usually
trowelled to close the surface
• Passive fire protection for use in tunnels
• Spray applied Colour .................................... off white
• Durable, impact resistant Components ........................... 1 (excluding water/additives)
• Modified vermiculite cement
3
• Tested to meet recognized international tunnel Dry density of the powder....... 465 kg/m
standards 3
Nominal dry density applied ... 725-775 kg/m
• Most fire ratings achieved in one single application
• Top coat systems to meet required colour and VOC ....................................... 0 g/l
reflectance levels
Curing mechanism ................. Hydrolisation
• Easy clean top coats
• Up to 4 hours insulation Thickness requirements ......... Contact PPG for details
Approvals
Steelguard CM 4701 is tested to resist fire conditions
in tunnels meeting recognized international tunnel
standards including the RATB in Germany,
Eurocode’s 1, 2 & 3 (EN 1991-1-2; EN 1992-1-2 & EN
1993-1-2) and the Dutch Rijkswaterstaat in
cooperation with the TNO Institute using the ‘RWS
97-CVB-R0710 Hydrocarbon time/temperature curve.
Project specific tunnel fire test may be required.
For suitable tunnel system specification contact PPG
for details.
Application Equipment
Use a mechanical piston or rotor stator type pump equipped
with a high-pressure plaster type hose avoiding brass or
aluminium type couplings. The flexible hose length should not
exceed 100 meters, with following typical length.
I.D. 75 mm (3”) maximum 100 meters
I.D. 50 mm (2”) maximum 50 meters
I.D. 35 mm (1 ½ ”) maximum 15 meters
I.D. 30 mm (1 ¼ ”) maximum 8 meters
For longer lengths use metal pipe with a I.D. of 65 -75 mm
Use as spray nozzle assembly a minimally 25-32 mm nozzle
with a 10 to 13 mm nozzle orifice and a rubber blow-off cap.
Atomising air should be 2-4 bar (28-57 psi) at the nozzle.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance ............................ sprayed textured finish, usually
trowelled to close the surface
• Passive fire protection for use in refineries and tank
storage facilities, in industrial and chemical plants and Colour .................................... grey
on offshore platforms.
• Meets international hydrocarbon fire standards Components ........................... 1 (excluding water/additives)
• Spray applied Dry density of the powder....... 465 kg/m
3
levelling by trowel this can be achieved by spray application At the end of the spray line 1050 – 1200 kg/m
3
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance ............................ sprayed textured finish, usually
trowelled to close the surface
• Passive fire protection for steel framed structures
• Spray applied Colour .................................... light grey
• Durable, impact resistant Components ........................... 1
• Modified vermiculite cement
3
• Up to 4 hours fire protection of structural steel Nominal dry density ............... 725-775 kg/m
• Most fire ratings achieved in one single application VOC ....................................... 0 g/l
• Excellent weathering resistance meeting upto ISO
12944 C5M requirements. Curing mechanism ................. Hydrolisation
levelling by trowel this can be achieved by spray application At the end of the spray line 1050 – 1200 kg/m
3
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance ............................ sprayed textured finish, usually
trowelled to close the surface
• Passive fire protection for steel framed
structures Colour .................................... grey
• Spray applied Components ........................... 1
• Robust coating for internal C1/C2
3
environments (ISO 12944) Nominal dry density ............... 350-400 kg/m
• Modified vermiculite cement VOC ....................................... 0 g/l
• Up to 4 hours fire protection of structural steel
• Most fire ratings achieved in one single Curing mechanism ................. Hydrolisation
application Loading requirements: In order to establish the thickness required
to give the specified fire resistance, reference should be made to
the products Hp/A (A/V) values or limiting temperature tables.
Typical Uses Contact your PPG representative for full details.
Steelguard CM 4704 is a tough hard and highly stable
passive fire protection for use on internal structural steel. Nominal usage at 25 mm thickness
The spray-applied coating shows excellent mechanical Per 25 kg sack........................ 2.65 m
2
resistance. It does not rely on any form of expansion, Per tonne................................ 106 m
2
levelling by trowel this can be achieved by spray application At the end of the spray line 900 – 1050 kg/m
3
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance ............................ clear when dry
• Additive for modified Steelguard CM Colour .................................... milky white liquid
vermiculate cement coatings
Components ........................... 1
• Adhesion promoter in bonding coat
• Improves substrate adhesion Specific gravity ....................... 1.08 kg/l
• Improves cohesive strength
pH........................................... 4.5 – 5.5
• Improves early water resistance
Volume solids ......................... 50% ± 2%
Application Procedure
Steelguard CM 4705 must be thoroughly stirred Application Data
before used. Thinner .................................. Do not thin
Shipping Data
Pack size ................................ 25 litre pails
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions
• Sealer coat for alkyd, unknown primers Physical Data
• Prevents primer saponification
• Adhesion promoter for primed steel Appearance ............................ matt
Theoretical coverage at 50
microns dry film thickness ..... 5.4 m²/litre
Surface Preparation
Ensure that the existing coating is clean, dry, sound Application Data
and free from any dirt, dust or contamination Substrate ................................ coated steel
immediately before coating. Any loose adherent
coating should be removed back to firm edge and Application method................. brush, roller, airless and
conventional spray
suitably patch repaired.
Environmental Conditions
Ambient temperature .......... 5 to 25°C 41 to 77ºF
Mixing Surface temperature: ........... 4°C/39ºF minimum
Steelguard CM 4706 must be thoroughly stirred
before use. Surface temperature must be at least 2°C/4°F above the dew point
to prevent moisture condensation on the surface.
Shipping Data
Pack size ................................ 25 litre pails
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Ɉɝɧɟɡɚɳɢɬɧɵɟɦɚɬɟɪɢɚɥɵ
> START
We Know...
Fire Protection
Coatings
Amercoat
®
Pitt-Char XP
Epoxy Intumescent Coating
Product Data/
Application Instructions Physical data
Finish...................................... glossy
• Superior fire & corrosion protection
Colour..................................... grey
• Unique flexibility
• Superior mechanical resistance Components ........................... 2
• Suitable for cryogenic exposure
Mixing ratio
• Complies with international fire standards By volume ............................ 2.33 part A to 1 part B
By weight ............................. 3.25 part A to 1 part B
Typical uses
Pitt-Char XP epoxy intumescent coating offers Curing mechanism ................. Chemical reaction between
components
outstanding fire protective properties. When exposed
to fire, its unique chemical composition transforms its Weight solids .......................... 100%
surface into ceramic-like, insulating char that provides
VOC*
thermal protection for the substrate even under EC SED 1999/13/EC ........... 0 g/kg (0 g/l)
hydrocarbon and jet fire conditions. UK PG6/23(92) Appendix 3 . 0 g/l (0 lbs/gal)
Because Pitt-Char is an epoxy, its tough, durable
Dry film thickness ................... Dependant on fire rating and
coating provides a dense shield to the elements. Pitt- loading factors
Char XP has resistance to solvents, acids, alkalies,
salts and abrasion making Pitt-Char the idea choice Wet film thickness per coat .... 6-8 mm (0.25-0.30”)
for harsh environments ranging from arctic to tropical Typical coverage
climates. For service applications exceeding 80°C 2
At 5 mm/0.2” ..................... 0.25 m /l
2
10.33 ft /gal
(176°F) consult your PPG Protective & Marine 2
At 10 mm/0.4” ...................... 0.12 m /l
2
5.17 ft /gal
Coatings representative. Pitt-Char coatings have
Flashpoints .............................
successfully protected substrates in refineries, Cure ..................................... over 100°C (212°F)
chemical plants, offshore platforms, and a variety of Resin.................................... over 100°C (212°F)
other ‘high risk’ industrial facilities all over the world. Thinner Type 47................... 44°C 111°F
Amercoat 12 ........................ 24°C 75°F
Amerrcoat 920 ..................... 24°C 75°F
Product fire test results
Thinner ................................... Thinner Type 47
Pitt-Char coatings have been fire tested at more than
12 fire testing facilities around the world. Our products Roller finish solvent** ............. Amercoat 920
have received approvals and certificates from Cleaning solvent..................... Amercoat 12
Underwriters’ Laboratories Inc. (USA and Canada),
Det Norske Veritas (Norway), Lloyd’s Registry (UK), * VOC figures are quoted according to both the EC directive
GASAFE (France), and from several customers 1999/13/EC which are theoretically calculated figures and the UK
PG6/23(92) Appendix 3 which are practically determined figures.
based on their own in-house fire testing. Testing has
covered a range of heat fluxes including jet fire ** Amercoat 920 can be used to wet rollers required to treat
inpingement testing on various steel section sprayed surfaces. It may not be used to thin material for appliaction
improvement.
geometries and sizes. A sampling of fire test results
are listed. For additional test information, including
actual explosion testing up to 1.8 bar average over
pressures and 3.0 peak over pressure, consult your
local PPG Protective & Marine Coatings
representative.
Environmental properties
Test conducted by Underwriters laboratories Inc. (UL) to ensure
retention of fire protection (UL 263 and UL 1709 test criteria)
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Описание материала/
Инструкция по нанесению
Физические характеристики
• Вспениваемое тонкопленочное покрытие на Внешний вид
в сухом состоянии.................... матовый
основе растворителя
• Протестировано на соответствие мировым Цвет .......................................... белый
стандартам
• Обеспечивает огнестойкость металлоконструкций Количество компонентов......... 1
до 2 ч
Содержание твердых
• Наносится на месте монтажа конструкции и в веществ*................................... 68±3%
цеховых условиях
• Толщина сухого слоя за проход до 1.5 мм Летучие органические
• Быстрота работ соединения**
• Не нуждается в использовании уплотнительного EC SED 1999/13/EC .............. 293г/кг (378 г/л)
UK PG6/23 (92) Приложение 3 325 г/л (2.7 lbs/gal)
слоя при нанесении на поверхности внутри сухих
помещений, если агрессивность среды C1
согласно ISO 12944 Механизм отверждения........... испарение растворителя
Разрешения
Толщина сухого слоя (µm) ...... 250 400 500 700 1500
Steelguard FM 549 был испытан согласно Национальным и
Международным стандартам на воздействие целлюлозного Толщина мокрого слоя (µm).... 370 590 740 1030 2205
пламени (ISO 834) и затем сертифицирован в соответствии
с национальными требованиями пожарной безопасности. Расчетная площадь
Для получения самой последней информации покрытия (м2/л)........................ 2.72 1.70 1.36 0.97 0.45
относительно требований локальных рынков и разрешений,
(Приведенная толщина мокрого слоя рассчитана теоретически для
пожалуйста, обращайтесь к местному представителю PPG покрытия нанесенного напылением)
Protective & Marine Coatings. Для конкретного проекта PPG
Protective & Marine Coatings может предоставить заказчику
данные по огнезащитной эффективности и расчет расхода Удельная масса ....................... 1,3 кг/л
материала для достижения требуемого уровня огнезащиты,
назначение стальных секций и местные требования Температура вспышки (с закрытым тиглем)
Steelguard FM 549 ................. 25°C 77ºF
пожарной безопасности. Могут быть изготовлены
Amercoat 65 ........................... 24°C 75ºF
стандартные таблицы огнезащитной эффективности.
* Объемы твердых веществ измеряются в соответствии с ASTM
D2697, с изменениями. Небольшие отклонения ± 3% могут иметь
место из-за различий по цвету и испытаниям.
APPROVED PRODUCT
CF 459
Порядок нанесения
1. Промойте перед использованием инвентарь в Транспортировка
рекомендованном очистителе.
2. Тщательно размешайте краску до однородного состояния с Объем тары........................... 20 л
помощью мощной смесительной установки.
3. Разбавлять краску, как правило, не требуется. Вес брутто ............................. около 28 кг
4. При использовании вакуумного распылителя наносите
влажное покрытие параллельными проходами. Во
избежание неокрашенности отдельных участков, наколов Предельный срок хранения . 12 месяцев при хранении в
или недостаточной толщины покрытия каждый помещении в закрытой
последующий проход должен перерывать предыдущий на оригинальной таре при
50%. температуре от 5 до 35°C (41-
5. Особое внимание обращайте на сварные швы, 104ºF).
шероховатости, заострённые кромки и углы, заклепки,
болты, и т.п.
6. Толщина мокрого слоя 370 микрон в нормальных условиях
обеспечивает толщину сухого слоя 250 микрон.
7. Проверьте толщину сухого покрытия средствами, не
нарушающими целостность покрытия (например,
приборами "Mikrotest" или "Elcometer"). По необходимости
нанесите дополнительный слой материала.
8 Небольшие повреждения поверхности или
неокрашенности, немногочисленные наколы или
недостаточная толщина покрытия отдельных участков
могут быть устранены с помощью кисти. Более серьезные
недостатки могут устраняться с использованием
распылителя или кисти (для Steelguard FM 549), а также
лопатки, ножа или шпателя (для Steelguard 2450).
9. При работе в закрытых помещениях обеспечьте
необходимую вентиляцию на период нанесения покрытия и
его сушки вплоть до полного испарения растворителя.
Температура и влажность воздуха, используемого для
вентиляции, должна устанавливаться так, чтобы не
допустить конденсацию влаги на поверхности.
10. Промойте инвентарь в рекомендованном очистителе после
использования или, как минимум, в конце каждого рабочего
дня или смены.
Условия продажи
Любые сделки, совершаемые компанией,
осуществляются в соответствии с установленными
сроками и условиями продажи.
Описание материала/
Инструкция по нанесению Физические характеристики
Внешний вид
в сухом состоянии ................ матовый
• Вспениваемое тонкопленочное покрытие на Цвет ....................................... белый
основе растворителя
• Протестировано на соответствие мировым Количество компонентов ..... 1
стандартам
• Обеспечивает огнеупорность Содержание твердых
металлоконструкций до 2 ч веществ*................................ 68±3%
• Наносится на месте монтажа конструкции или в
цеху Летучие органические
соединения**
• Толщина сухой пленки за один слой - до 1.5 мм
EC SED 1999/13/EC .............. 293г/кг (378 г/л)
• Быстрота проведения работ UK PG6/23 (92) Приложение 3 325 г/л (2.7 lbs/gal)
• Подходит для эксплуатации в средах с
агрессивностью C1, C2, C3 & C4 на конструкциях Механизм отверждения ....... испарение растворителя
внутри и вне помещений – в сухих средах внутри
помещений с агрессивностью C1 (ISO 12944) Ограничения по нагрузкам... Для получения толщины сухой
нанесение уплотнительного слоя не требуется пленки, обеспечивающей
требуемую огнестойкость,
расчеты проводите на основе
Типовые условия использования данных по соотношению
-1
Покрытие предназначено для обеспечения огнеупорности Hp/A m (A/V) для покрытия или
внутренних и внешних металлоконструкций за счет по таблицам критических
вспенивания под воздействием высоких температур. температур. За подробной
Покрытие Steelguard FM 550 наносится за пределами информацией обращайтесь в
строительной площадки вручную и машинным способом с местное представительство
компании "PPG".
помощью аппарата, оборудованного подогревателем и
механизмом ускоренной просушки. Толщина сухого слоя (µm) ... 250 400 500 700 1500
APPROVED PRODUCT
CF 456
Методы нанесения
Для получения наиболее гладкого покрытия наносите краску
методом распылением. Нанесение с помощью кисти придает
поверхности фактурность.
БЕЗВОЗДУШНЫЙ РАСПЫЛИТЕЛЬ - Используйте нагнетатель,
способный создать на выходе давление не менее 2800
2 2
фунтов/дюйм (200 кг/см ). Рекомендуемый внутренний фильтр
– 30 меш /500 мкм. Размер сопла – 19 – 33 тыс. (0.48-0.83мм).
При нанесении вне места монтажа конструкции рекомендуется
чтобы 700 мкм слоя наноситься по прошествию 8 часовой
просушки при температуре 15°C/59ºF, максимальная толщина
сухого слоя при этом должна быть не более 1.0 мм на
покрытие.
КИСТЬ - Наносите краску ровным слоем, используя чистую
кисть подходящего размера. Толщина сухого слоя при этом не
должна превышать 300 микрон на покрытие. Последующие
слои могут наноситься не ранее чем через 2 часа просушки при
температуре 20°C/68ºF.
Отверждение
Время отверждения сильно варьируется в зависимости от
условий окружающей среды, метода нанесения покрытия, Hp/A
(A/V) покрываемого участка, толщины наносимого покрытия и
использования режима предварительного нагрева и
принудительной сушки. Для ориентира можно привести
следующие данные: при температуре 15°C/59ºF покрытие
толщиной 400 микрон будет сухим на ощупь примерно через 1
ч и достигнет высыхания по всей толщине слоя примерно
через 48 ч. За более подробной информацией по времени
отверждения покрытия Steelguard FM 550 обращайтесь к
таблице времени отверждения или в местное
представительство компании "PPG".
Поверхностное покрытие
Типовой материал, рекомендуемый в качестве покрывного для Транспортировка
Steelguard FM 550 - Steelguard 2458, позволяющий нанести 9. При работе в закрытых помещениях обеспечьте
покрывной слой и завершить выполнение работ. Другие необходимую вентиляцию на период нанесения
разрешенные покрывные материалы, которые, однако, имеют покрытия и его сушки вплоть до полного испарения
более продолжительное время межслойной сушки - Amercoat растворителя. Температура и влажность воздуха,
450S, Amercoat 4310, Amercoat 2136 and PSX 700#. используемого для вентиляции, должна
Уплотнительный слой при эксплуатации внутри помещений с устанавливаться так, чтобы не допустить
агрессивностью C1 , если иное не требуется по эстетическим конденсацию влаги на поверхности.
соображениям. При эксплуатации Steelguard FM 550 внутри 10. 10.Промойте инвентарь в рекомендованном
помещений с агрессивностью C2 необходимо очистителе после использования или, как минимум, в
соответствующим образом нанести уплотнитель Steelguard конце каждого рабочего дня или смены.
2458 с толщиной сухой пленки 60 мкм или другой
рекомендованный покрывной материал.
В условиях агрессивности C3 и C4 при эксплуатации вне Перед использованием продукции прочтите этикетку на банке
помещений Steelguard FM 550 должне быть соответствующим и ознакомьтесь с формуляром по технике безопасности.
образом уплотнен двумя слоями Steelguard 2458 с общей
толщиной сухой пленки 120 мкм или другим разрешенным
покрывным материалом. Пожалуйста, свяжите с
представителем компании PPG за разъяснениями по Транспортировка
конкретным ситуациям. Важно, чтобы требуемая толщина
вспенивающегося покрытия была достигнута до нанесения Объем тары........................... 20 л и 200 л
покрывного материала.
(#требуется также Amercoat 71TC в качестве клеевого слоя) Вес брутто ............................. около 29 кг (20 л)
Если стальная поверхность соответствующим образом
загрунтована, а толщина сухой пленки вспенивающегося Предельный срок хранения 1 год с момента отгрузки при при
покрытия более 250 мкм, Steelguard FM 550, будучи хранении в помещении в
нанесенным на конструкции вне помещений, может оставаться закрытой оригинальной таре при
без поверхностного покрытия до 12 месяцев. На это время, тем температуре от 5 до 40°C (41-
не менее, Steelguard FM 550 должен быть защищен от стоячей 104ºF).
и проточной воды, воздействия горячих влажных сред и
работы в погружении. Необходимо обеспечить необходимое
время сушки для Steelguard FM 550 перед эксплуатацией вне
помещений. К примеру, при 15°C (59°F) и толщине сухой
пленки 700 мкм, минимальное рекомендованное время сушки
до эксплуатации вне помещений составляет 40 ч со времени
нанесения последнего слоя.
См. таблицы по времени сушки и перекрытия.
Порядок нанесения
1. Промойте перед использованием инвентарь в
рекомендованном очистителе.
2. Тщательно размешайте краску до однородного состояния с
помощью мощной смесительной установки.
3. Разбавлять краску, как правило, не требуется.
4. При использовании вакуумного распылителя наносите
влажное покрытие параллельными проходами. Во
избежание неокрашенности отдельных участков, наколов
или недостаточной толщины покрытия каждый
последующий проход должен перерывать предыдущий на
50%.
5. Особое внимание обращайте на сварные швы,
шероховатости, заострённые кромки и углы, заклепки,
болты, и т.п.
6. Толщина мокрого слоя 590 микрон в нормальных условиях
обеспечивает толщину сухого слоя 400 микрон.
7. Проверьте толщину сухого покрытия средствами, не
нарушающими целостность покрытия (например,
приборами "Mikrotest" или "Elcometer"). По необходимости
нанесите дополнительный слой материала.
8. Небольшие повреждения поверхности или
неокрашенности, немногочисленные наколы или
недостаточная толщина покрытия отдельных участков
могут быть устранены с помощью кисти. Более серьезные
недостатки могут устраняться с использованием
распылителя или кисти (для Steelguard FM 550, а также
лопатки, ножа или шпателя (для Steelguard 2450).
Условия продажи
Любые сделки, совершаемые компанией,
осуществляются в соответствии с установленными
сроками и условиями продажи.
Физические Свойства
Информация о Продукте /
Инструкция по Нанесению Вид сухого покрытия ……. матовая поверхность
• Тонкослойное, вспучивающееся покрытие на
основе органического растворителя Цвет ………………………... белый, серый
• Обеспечивает противопожарную защиту
конструкционной стали в течение 60 минут Компонентов ……………… 1
• Наносится в заводских условиях или в поле на
месте эксплуатации объекта Объемный сухой
• Наносится толщиной сухой пленки до 1.5 мм за остаток * …………………… 75 + 3%
один слой
• Применяется для внутренних и наружных Содержание летучих
поверхностей для категорий коррозионной веществ**……………………
активности С1, С2, С3 и С4. При эксплуатации
внутри помещений с сухой атмосферой категории
С1 (ISO 12944), не требуется применения EC SED 1999/13/EC .............. 257 г/кг (346г/л)
изолирующего покрытия.)
UK PG6/23 (92) Приложение 3 ….330 г/л
Механизм отверждения … Испарение растворителя
Область Применения
Вспучивающееся огнезащитное покрытие для защиты
конструкционной стали эксплуатирующейся внутри помещений Требования по нагрузкам …... Определение толщины сухой
и на открытом воздухе. Применяется для защиты пленки, требуемой для
(дву)тавровых колонн, балок и полых конструкций. достижения заданного
Предназначен для нанесения ручным безвоздушным уровня огнестойкости,
распылением в полевых условиях. Может быть нанесен также производится на основе
кистью. Материал может также наноситься в заводских обратной величины
условиях ручным безвоздушным распылением или приведенной толщины
-1
автоматическими распылителями с предварительным металла A/V м (Hp/A) или
подогревом и оборудованием для ускоренной сушки. В таблиц предельной
нормальных условиях Steelguard 551 устойчив к атмосферному температуры.
воздействию до 12 месяцев, что облегчает транспортировку,
хранение и монтаж элементов конструкции при строительстве Толщина сухой пленки (мкм)....200 400 500 700 1000
объекта. В течение этого периода необходимо избегать
Толщина жидкой пленки (мкм)..270 535 665 935 1335
действия проточной/стоячей воды, горячей влажной
атмосферы и эксплуатации в погруженном состоянии. Теоретический Расход (м2/л)... 3.75 1.88 1.50 1.07 0.75
Параметры Высыхания
Время высыхания будет существенно меняться в зависимости
от окружающих условий, обратной величины приведенной
-1
толщины металла A/V м (Hp/A) окрашенной секции и толщины
О
покрытия. В качестве ориентира, при 15 С и 700 мкм сухой
пленки, покрытие будет высыхать «на отлип» примерно через
1 час, а до твердого состояния примерно через 40 часов.
Более подробную информацию о времени высыхания
Steelguard 551 см. в таблицах высыхания продукта или
обращайтесь к представителю PPG.
Перекрытие
Стандартным, рекомендованным финишным покрытием для
Steelguard 551 является Steelguard 2458, которое позволяет
быстро перекрыть основное покрытие и закончить работы.
Другими одобренными финишными покрытиями, но с
большими периодами перекрытия, являются Amercoat 450
Серия, Amercoat 4310, Amercoat 2136 и PSX 700 *. Для условий
эксплуатации внутри помещений с категорией С1
изолирующее покрытие не требуется, кроме как для
косметических целей. Для условий эксплуатации внутри
Условия Продажи
Любые сделки, совершаемые компанией,
осуществляются в соответствии с установленными
Правилами и Условиями Продаж.
Цвет .......................................
матовый
Белый, серый
Летучие органические
• Быстросохнущее вспениваемое тонкопленочное покрытие
на основе растворителя соединения**
• Быстрая сушка уменьшает время до эксплуатации EC SED 1999/13/EC ........... 294г/кг (377 г/л)
конструкции UK PG6/23 (92) Приложение 3 325 г/л
• Протестировано на соответствие мировым стандартам
Летучие органические соединения 325 г/л
• Обеспечивает огнеупорность металлоконструкций до 2 ч
• Наносится как на месте монтажа конструкции, так и вне его Механизм отверждения ....... испарение растворителя
• Толщина сухой пленки на слой до 1.0 мм Ограничения по нагрузкам... Для получения толщины сухого
• Подходит для использования в средах с агрессивностью слоя, обеспечиваю-щего
С1, , C2, C3 и C4 внутри и вне помещений – при требуемую огнестойкость,
использовании в внутри сухих помещений с расчеты проводите на основе
-1
агрессивностью С1 (ISO 12944) не нуждается в данных по Hp/A m (A/V)
использовании внешнего покрытия покрытия или по таблицам
критических температур. За
подробной информацией
Типовые условия использования обращайтесь в местное
Покрытие предназначено для обеспечения огнеупорности представительство компании
внутренних и внешних металлоконструкций за счет "PPG".
вспенивания под воздействием высоких температур. Покрытие
Steelguard 560 представляет собой более быстросохнущую Толщина сухого слоя (мкм).. 250 400 500 700 1000
версию покрытия Steelguard 560 и предназначено для нанесения
за пределами строительной площадки вручную с помощью Толщина мокрого слоя (мкм) 370 590 740 1030 1470
вакуумного распылителя. Позволяет экономить время, 2
предупреждать механические повреждения на раннем этапе, Расчетная площадь покрытия (м /л)2.72 1.70 1.36 0.97
повысить производительность покрасочных работ. Может 0.68
использоваться для внутренних поверхностей.
(Приведенная толщина мокрого слоя рассчитана теоретически
для покрытия нанесенного напылением)
Разрешения
Удельная масса .................... 1,3 кг/л
Steelguard 560 был испытан согласно Национальным и
Международным стандартам на воздействие целлюлозного Температура вспышки (с закрытым тиглем)
пламени (ISO 834) и затем сертифицирован в соответствии с
национальными требованиями пожарной безопасности. Для Steelguard 560 ...................... 4°C/39ºF
получения самой последней информации относительно
требований локальных рынков и разрешений, пожалуйста, Amercoat 12 ........................... 24°C/75ºF
обращайтесь к местному представителю PPG Protective & * Объемы твердых веществ измеряются в соответствии с
Marine Coatings. Для конкретного проекта PPG Protective & ASTM D2697, с изменениями. Небольшие отклонения ± 3%
Marine Coatings может предоставить заказчику данные по могут иметь место из-за различий по цвету и испытаниям.
огнезащитной эффективности и расчет расхода материала для
достижения требуемого уровня огнезащиты, назначение ** Содержание летучих органических соединений приведено
стальных секций и местные требования пожарной согласно директиве ЕС 1999/13/EC - на основе теоретических
безопасности. Могут быть изготовлены стандартные таблицы расчетов, и согласно требованиям UK PG6/23(92) Приложение
огнезащитной эффективности. 3 - на основе практических данных.
APPROVED PRODUCT
CF 457
Подготовка поверхности
Покрытие наносится на обработанную пескоструйным Информация по нанесению
способом и загрунтованную стальную основу. При
необходимости высушите и очистите поверхность от пыли, Основа ................................... загрунтованная сталь
солей, смазки и других загрязнителей непосредственно перед
нанесением покрытия. При нанесении грунта следуйте Средства нанесения............ вакуумный распылитель, кисть
инструкциям, приведенным в спецификации, предварительно (для небольших поверхностей)
убедившись, что он одобрен к применению компанией "PPG" и
Условие окружающей среды
совместим с покрытием Steelguard 560. Общая толщина
Относительная влажность
сухого слоя грунта не должна превышать 150 микрон. Для
воздуха:............................... до 85%
эпоксидных материалов максимальная разрешенная толщина
сухой пленки должна быть увеличена. Обратитесь к Минимальная температура
представителю компании PPG перед нанесением
вспенивающегося покрытия. поверхности: ......................... 5 -50°C 41- 122ºF
При нанесении на внешнюю поверхность, покрытие Steelguard
560 может ложиться непосредственно на обработанную Максимальная температура
пескоструйным способом основу, если условия окружающей
среды соответствуют требованиям п. C1 ISO 12944, а толщина поверхности: ...................... 5 -50°C 41- 122ºF
сухой пленки – не менее 400мкм. Поверхность должна быть
отшлифована до степени Sa 2 (ISO 8501-1) струей песка Кроме того, температура поверхности должна быть выше точки
средним диаметром 50- 75 микрон, и максимальным - 100 росы не менее чем на 3°C/5ºF
микрон. Покрытие необходимо нанести до ухудшения
характеристик. Поверхности. В случае окисления проведите Жизнеспособность ............... Не указана
повторную обработку поверхности. При необходимости
Разбавитель.......................... Обычно не требуется
высушите и очистите поверхность от пыли, солей, смазки и
других загрязнителей перед нанесением покрытия. При необходимости можно использовать Amercoat 65 (до 5%
по объему), однако, в этом случае результат измерения
толщины жидкой/сухой пленки будет ниже максимального
Порядок смешения значения и толщину необходимо будет рассчитать.
Перед нанесением тщательно размешайте краску до
Очиститель............................ Amercoat 12
однородного состояния с помощью мощной смесительной
установки. Это может вызвать видимое разжижение
материала, что является нормальным.
Методы нанесения
БЕЗВОЗДУШНЫЙ РАСПЫЛИТЕЛЬ – Используйте нагнетатель
способный создать на выходе давление не менее 2800
2 2
фунтов/дюйм (200 кг/см ). Рекомендуемый внутренний фильтр
– 30 меш /500 микрон. Размер сопла - 0.48-0.63мм. При
нанесении вне строительной зоны рекомендуемая толщина
покрытия составляет 700 микрон. Последующие слои могут
наноситься по прошествию 6 часовой просушки при
температуре 15°C/59ºF.
КИСТЬ - Применяется для небольших поверхностей,
например, в ходе ремонтных работ. Наносите краску ровным
слоем, используя чистую кисть подходящего размера.
Толщина сухого слоя при этом не должна превышать 300
микрон на покрытие. Последующие слои могут наноситься не
ранее чем через 2 часа просушки при температуре 20°C/68ºF.
Отверждение
Время отверждения сильно варьируется в зависимости от
условий окружающей среды, метода нанесения покрытия,
-1
A/V m (Hp/A) покрываемого участка, толщины наносимого
покрытия и использования режима предварительного нагрева
и принудительной сушки. Для ориентира можно привести
следующие данные: при температуре 15°C/59ºF покрытие
толщиной 700 микрон будет сухим на ощупь примерно через
30 мин и достигнет высыхания по всей толщине слоя примерно
через 20 ч. За более подробной информацией по времени
отверждения покрытия Steelguard 560 обращайтесь к таблице
времени отверждения или в местное представительство
компании "PPG".
Порядок нанесения
1. Промойте перед использованием инвентарь в
рекомендованном очистителе.
2. Тщательно размешайте краску до однородного
состояния с помощью мощной смесительной
установки.
3. Разбавлять краску, как правило, не требуется.
4. При использовании вакуумного распылителя
наносите влажное покрытие параллельными
проходами. Во избежание неокрашенности
отдельных участков, наколов или недостаточной
толщины покрытия каждый последующий проход
должен перерывать предыдущий на 50%.
5. Особое внимание обращайте на сварные швы,
шероховатости, заострённые кромки и углы,
заклепки, болты, и т.п.
6. Толщина мокрого слоя 590 микрон в нормальных
условиях обеспечивает толщину сухого слоя 400
микрон.
7. Проверьте толщину сухого покрытия средствами, не
нарушающими целостность покрытия (например,
приборами "Mikrotest" или "Elcometer"). По
необходимости нанесите дополнительный слой
материала.
8 Небольшие повреждения поверхности или
неокрашенности, немногочисленные наколы или
Условия продажи
Любые сделки, совершаемые компанией, осуществляются в
соответствии с установленными сроками и условиями
продажи.
Product Data/
Application Instructions Physical Data
Appearance when dry ............ matt
• Fast drying solvent based thin film intumescent Colour .................................... white, grey
• Rapid drying providing reduced times to handling
Components ........................... 1
• 60 minutes fire protection of structural steel
• Off-site or on-site application Volume solids *....................... 75 ± 3%
• Up to 1.0 mm dry film thickness application in a
VOC**
single coat
• For use in C1, C2, C3 & C4 internal & external EC SED 1999/13/EC .............. 255 g/kg (343 g/l)
environments - no sealer coat required for dry
UK PG6/23 (92) Appendix 3... 327 g/l
internal C1 service conditions (ISO 12944)
Curing mechanism ................. solvent release
APPROVED PRODUCT
CF 550
•
Mixing
Stir thoroughly before use until the product is uniform throughout.
This may cause an apparent thinning effect which is normal for this
product. A power mixer should be used.
Application Methods
AIRLESS SPRAY - Use a pump capable of producing a minimum
pressure at the tip of 2800 psi (200 kg/cm²). A 30 mesh/500 micron
internal filter is recommended. Tip size 19-25 thou’ (0.48-0.63mm).
For off-site application it is recommended that the product is
applied in 700 microns dry film thickness coats allowing a minimum
of 6 hours drying at 15°C (59°F) between each coat.
BRUSH – Suitable only for small areas such as repairs. Apply
evenly using a clean, well-loaded brush at up to 300 microns dry
film thickness per coat. As a guide allow at least 2 hours drying at
20°C (68°F) between coats.
Drying Characteristics
Drying times will vary considerably depending on ambient
-1
conditions, A/V m (Hp/A) of section being coated and applied film
thickness. As a guide, at 15°C (59°F) a 700 microns dry film
thickness coating will be touch dry in 30 minutes and hard dry after
approximately 20 hours. For further details on the drying times of
Steelguard 561 refer to the product drying tables or contact your
PPG representative.
Overcoating
The standard recommended topcoat for Steelguard 561 is
Steelguard 2458 which allows for fast overcoating and job
completion. Other approved topcoats but with longer overcoating
periods include Amercoat 450 series, Amercoat 4310, Amercoat
2136 and PSX 700#. No sealer is required for internal C1 service
conditions unless for cosmetic reasons. For internal C2 service
conditions Steelguard 561 must be adequately sealed with
Steelguard 2458 at 60 microns dry film thickness or other approved
topcoat. For C3 & C4 external service conditions Steelguard 561
must be adequately sealed with two coats Steelguard 2458 at 120
microns total dry film thickness or other approved topcoat. Please
contact your PPG representative for specific recommendations. It is
important that the specified intumescent thickness has been
achieved before any topcoating.
(# Amercoat 71TC required as a tie coat)
Application Procedure:
1. Flush equipment with recommended cleaner before use.
2. Stir to an even consistency with a power mixer.
3. Thinning is normally not required for airless spray.
4. For airless spray apply a wet even coat in parallel passes.
Overlap each pass 50% to avoid bare areas, pinholes or
holidays.
5. Give special attention to welds, rough spots, sharp edges
and corners, rivets, bolts, etc.
6. Application at 540 microns wet film thickness will normally
provide 400 microns dry film.
7. Check thickness of dry coating with a non- destructive dry
film thickness gauge, such as Mikrotest or Elcometer. If
less than specified thickness, apply additional material as
needed.
8. Limited areas of damage should be repaired using
Steelguard 2451 intumescent repair compound to the
specified dry film thickness. Repair larger areas by airless
spray using Steelguard 561.
9. For repair of damaged primerless systems where bare
steel is exposed, a suitable primer should be applied prior
to re-application of the intumescent coating.
10. In confined areas ventilate with clean air during
application and drying until all solvents are removed.
Temperature and humidity of ventilating air must be such
that moisture condensation will not form on surface.
11. Clean all equipment with recommended cleaner
immediately after use or at least at the end of each working
day or shift.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
APPROVED PRODUCT
CF 458
Отверждение
Время отверждения сильно варьируется в зависимости от
условий окружающей среды, метода нанесения покрытия,
-1
вентиляции, Hp/A (A/V ) покрываемого участка и толщины
наносимого покрытия. Для ориентира можно привести
следующие данные: при температуре 20°C/68ºF и
относительной влажности 50% покрытие толщиной 400 микрон
будет сухим на ощупь примерно через 2 ч и достигнет
высыхания по всей толщине слоя примерно через 4 ч. За
более подробной информацией по времени отверждения
покрытия Steelguard FM 580 обращайтесь к таблице времени
отверждения или в местное представительство компании
"PPG".
Поверхностное покрытие
Хотя необходимости использования покрывного слоя в
качестве для обеспечения защитных свойств в сухих средах с
агрессивностью С1 нет, для декоративных целей
рекомендуется использовать водоразбавимые материалы
серии Amercoat 220. Steelguard FM 580 необходимо выдержать
не менее 4 ч при 20 C (68 F) до нанесения Amercoat 220. За
более подробной информацией и данным по другим
покрывным материалам, которые допускается использовать
совместно с покрытием Steelguard 2458, свяжитесь с
представителем компании PPG. Необходимо помнить, что
требуемая толщина вспениваемого покрытия должна быть
набрана до нанесения покрывного слоя
Условия продажи
Любые сделки, совершаемые компанией,
осуществляются в соответствии с установленными
сроками и условиями продажи.
APPROVED PRODUCT
CF 460
Подготовка поверхности
Steelguard FM 585 наносится на стальную поверхность,
предварительно прошедшую абразивоструйную Информация по нанесению
подготовку и соответствующим образом
Субстрат................................ загрунтованная сталь,
загрунтованную. Поверхность должна быть очищена от
подготовленная абаразиво-
грязи, пыли, цемента, солей, масел и других струйным способом
загрязнителей непосредственно перед нанесением
покрытия. Используемый грунт должен наноситься Метод нанесения .................. безвоздушное распыление,
согласно инструкции. Выбор грунта должен быть кисть, валик
согласован с компанией PPG на предмет его
Условия окружающей среды
совместимости с покрытием Steelguard FM 585.
Относительная влажность до 80%
Запрещается наносить Steelguard FM585 Температура поверхности. 5 - 40°C (41 - 104°F)
непосредственно по покрытиям, содержащим цинковый
порошок. Общая толщина грунтовочных покрытий не Steelguard FM585 эксплуатируется исключительно в сухих
должна превышать 150 мкм. условиях внутри помещений с невысокой влажностью, без
конденсата.
Условия продажи
Любые сделки, совершаемые компанией,
осуществляются в соответствии с установленными
сроками и условиями продажи.
Product Data/
Application Instructions Physical Data
Appearance when dry ............ matt
• Solvent based intumescent repair compound Colour..................................... white
• Up to 2 mm dry film thickness per coat
Components ........................... 1
• Rapid job completion
Curing mechanism ................. solvent release
Flashpoint
(closed cup) ........................ ºC ºF
Steelguard 2450 .................. 26 79
Amercoat 65 ........................ 24 75
Cleaner................................... Amercoat 65
Application Procedure
Apply by trowel, knife or spatula. The coating should Shipping Data
be applied slightly proud of the surrounding area to Pack size ................................ 2.5 litres
allow for shrinkage on drying.
Shipping weight ...................... approx. 5kg
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Product Data/
Application Instructions Physical Data
Appearance when dry ............ matt
• Solvent based intumescent repair compound Colour..................................... white
• Up to 2 mm dry film thickness per coat
Components ........................... 1
• Rapid job completion
Curing mechanism ................. solvent release
Flashpoint
(closed cup) ........................ ºC ºF
Steelguard 2451 .................. 26 79
Amercoat 65 ........................ 24 75
Surface Preparation
Cut out the Steelguard intumescent to one or two Application Data
centimetres from the damaged area in all directions Substrate ................................ primed steel (previously abrasive
back to a sound edge (large enough to allow for blasted)
suitable preparation). Ensure the exposed substrate
Application methods ............... trowel, knife or spatula
is clean dry and free of contamination. If a topcoat
has been applied this should be lightly sanded to Environmental conditions
remove from possible overlap areas. Where Relative humidity ................. up to 85%
Surface temperature ............ 5 - 40°C (41-104°F)
Steelguard intumescent has been applied directly to Air temperature .................... 5 - 40°C (41-104°F)
blast cleaned steel, any areas of breakdown should
be abrasive blast cleaned to ISO 8501-1, Sa 2½ or Surface temperature must be at least 3°C/5°F above dew point to
where this is not practical manually clean to ISO prevent moisture condensation on the surface.
8501-1 St2 minimum. A suitable PPG approved Drying times at 2mm wet film and 20°C/68°F
primer such as Amerlock 2C or 400C should then be touch dry .............................. 2 hours
applied before degradation of the surface takes place. handle dry ............................ 48 hours
fully cured ............................ 7 days
Where a primer has been originally used any areas of
breakdown should be repaired in accordance with the Drying time will vary considerably with the thickness applied and
original specification using a primer approved by ambient conditions.
PPG. If Steelguard 2451 is applied over other Overcoating times (minimum) at 20°C/68°F with itself and
manufacturers primers, compatibility must be checked Steelguard 2458
with your PPG representative prior to application. up to 0.5 mm dft................... 6 hours
0.5-1.0 mm dft...................... 12 hours
1.0-1.5 mm dft...................... 18 hours
Mixing 1.5-2.0 mm dft...................... 24 hours
Stir by hand to homogenise the product before use
Potlife ................................... not applicable
Cleaner................................... Amercoat 65
Application Procedure
Apply by trowel, knife or spatula. The coating should Shipping Data
be applied slightly proud of the surrounding area to Pack size ................................ 2.5 litres
allow for shrinkage on drying.
Shipping weight ...................... approx. 5kg
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Dry film thickness (µm) .......... 250 400 500 700 1000
Approvals Wet film thickness (µm)
Steelguard FM 2570 has been tested to National and 373 597 746 1045 1493
2
International standards for cellulosic fire exposure (ISO Theoretical coverage (m /l) ….
2.68 1.68 1.34 0.96 0.67
834) and subsequently assessed and certified in
(wet film thicknesses quoted are
accordance with various National requirements. Please theoretical for one airless spray
contact your PPG Protective and Marine Coatings coat)
representative for latest information relating to local market
requirements and approvals. For given projects PPG Specific gravity ....................... 1.27 kg/l
Protective and Marine Coatings can provide customers with
Flashpoint
loading data and material consumption calculations
(closed cup) ......................... ºC ºF
stipulated by required fire protection, steel section Steelguard FM 2570 ......... 26 79
designation and local requirements. Standard loading tables Amercoat 12 ..................... 24 75
can be made available where applicable.
APPROVED PRODUCT
CF 542
Application Methods
AIRLESS SPRAY - Use a pump capable of producing a
minimum pressure at the tip of 2800 psi (200 kg/cm²). Tip
size 19-25 thou’ (0.48-0.63mm).
BRUSH – Suitable only for small areas such as repairs.
Apply evenly using a clean, well-loaded brush at up to
300microns dft per coat. Allow at least 4 hours drying at
20ºC/68ºF between coats.
Application Procedure:
1. Flush equipment with recommended cleaner before use. Shipping Data
2. Stir to an even consistency with a power mixer.
Pack size ................................ 20 litres
3. Thinning is normally not required for airless spray.
4. For airless spray apply a wet even coat in parallel Shipping weight ..................... approx. 27 kg (20 l)
passes. Overlap each pass 50% to avoid bare areas,
pinholes or holidays. Shelf life ................................. 12 months when stored indoors in
5. Give special attention to welds, rough spots, sharp unopened, original containers at 5
to 30°C (41 to 86ºF).
edges and corners, rivets, bolts, etc.
6. Application at 600 µm wet film thickness will normally
provide 400 µm dry film.
7. Check thickness of dry coating with a non- destructive
dry film thickness gauge, such as Mikrotest or
Elcometer. If less than specified thickness, apply
additional material as needed.
8. Small damaged or bare areas and random pinholes or
holidays can be touched up by brush. Repair larger
areas either by spray or brush with Steelguard FM 2570.
9. In confined areas ventilate with clean air during
application and drying until all solvents are removed.
Temperature and humidity of ventilating air must be
such that moisture condensation will not form on
surface.
10. Clean all equipment with recommended cleaner
immediately after use or at least at the end of each working
day or shift.
Before using the product, read the label on the can and
consult the material safety data sheet.
Condition of Sale
All our transactions are subject to our Terms and Conditions
of Sale.
Ƚɪɭɧɬɨɜɨɱɧɵɟɩɨɤɪɵɬɢɹ
Amercoat 68E
Amercoat 68G
Amercoat 139
Steelguard 3290
> START
We Know...
Fire Protection
Coatings
Amercoat
Amercoat 68E
Цинкнаполненный эпоксидный грунт
Описание материала/
Инструкция по нанесению Физические характеристики
Внешний вид ......................... матовый
• Сухой остаток содержит не менее 85% цинка Цвет ....................................... красноватый, серый
по весу
Число компонентов............... 2
• Сочетает высокую прочность, характерную
для эпоксидов, с защитными свойствами Коэффициент смешения
цинка (по объему)
отвердитель........................ 1 часть
• Высочайшая устойчивость к воздействию
смола .................................. 4 части
жестких погодных условий
• Отличные характеристики при эксплуатации Механизм отверждения ....... испарение растворителя и
в промышленных и морских средах взаимодействие компонентов
• Легко наносится с помощью безвоздушного Массовая доля нелетучих
или стандартного распылителя веществ ................................. 57 % (ISO 3233)*
Летучие органические
Область применения соединения**
При использовании совместно с соответствующими EC SED 1999/13/EC ........... 148 g/kg (410 g/l)
покрывными материалами Amercoat 68E может UK PG6/23(92) Appendix 3 . 363 g/l (3.0 lbs/gal)
использоваться в следующих областях.
ПРОМЫШЛЕННЫЕ СРЕДЫ – конструкционная сталь, Толщина сухой пленки ......... 50 - 75 мкм (2 - 3 милс) на слой
трубопроводы промышленного оборудования, а также
внешние поверхности -резервуаров на целлюлозно- Количество слоев ................. 1
бумажном и нефтеперерабатывающем производстве,
Расчетная укрывистость ...... 7,6 м²/л (при 75 мкм)
электростанциях, химических заводах и очистных станциях. 2
309,6 футов /галлон (при 3 милс)
МОРСКИЕ СРЕДЫ - Палубы, корпуса и надстройки на
кораблях, баржах и вспомогательных судах. А также При расчете следует учитывать факторы потерь при
эстакады, морские платформы и сопутствующие нанесении, неоднородность поверхности и т.п.
конструкции.
Удельная масса .................... 2,8 кг/л (mixed product)
Основные характеристики
Amercoat 68E представляет собой двухкомпонентный Термостойкость .................... 205°C (400°F) при сухом жаре
эпоксидный грунт с высоким содержанием цинка. Наличие
Температуры вспышки
цинка позволяет обеспечить катодную защиту и (при закрытом тигле) ............ °C °F
устойчивость к подрезам, даже если пленка повреждена. смола .................................. 23 73
При использовании в качестве составляющей отвердитель........................ 18 64
антикоррозионной системы Amercoat 68E демонстрирует Amercoat 9HF ..................... 26 79
отличные характеристики в широком спектре коррозионных
нагрузок. Будучи перекрытым соответствующим финишным Разбавитель/очиститель ..... Amercoat 9HF
слоем, материал устойчив к брызгам и проливам воды,
растворителей, химических веществ и нефтепродуктов.
* Содержание нелетучих веществ замерено в соответствии со
Сертификаты стандартом ISO 3233. Незначительное отклонение (около ± 3%) может
Отвечает требованиям стандарта SSPC Paint 20к составу быть вызвано изменчивостью условий испытаний и цвета покрытия.
ЛКМ 20, согласно ISO 12944 части 5, BS4652 и BS5493.
Amercoat 68E также соответствует требованиям крупных ** Содержание летучих органических соединений приведено согласно
директиве ЕС 1999/13/EC , на основе теоретических расчетов, и
нефтяных компаний, в частности Total/Elf/Fina, согласно требованиям UK PG6/23(92) Приложение 3, на основе
ADMA/OPCO и Aramco АПК 1C & 1F и спецификации практических данных.
Deutschebahn DB-TL 918300 Blatt 87
Amercoat 68E
Описание материала/
Инструкция по нанесению Физические характеристики
Внешний вид ......................... матовый
• Высокое содержание цинка в сухой пленке Цвет ....................................... красноватый, серый
• Сочетает высокую прочность, характерную
Число компонентов............... 2
для эпоксидов, с защитными свойствами
цинка Коэффициент смешения
• Высочайшая устойчивость к воздействию (по объему)
отвердитель........................ 1 часть
жестких погодных условий
смола .................................. 4 части
• Отличные характеристики при эксплуатации
в промышленных и морских средах Механизм отверждения ....... испарение растворителя и
взаимодействие компонентов
• Легко наносится с помощью безвоздушного
или стандартного распылителя Массовая доля нелетучих
веществ ................................. 62 % (ISO 3233)*
Описание материала/
Инструкция по нанесению
• Используется в качестве поддающейся сварке Физические характеристики
подготовительной грунтовки или в качестве
грунтовки, наносимой в полевых условиях или на Отделка ................................. Матовая
заводе
• Обеспечивает почти сразу же после нанесения Цвет ....................................... красный оксид и серый
возможность транспортировки, выполнение
Компоненты........................... 2
сварочных работ, резку и обработку
• Может использоваться с разнообразными верхними Соотношение для смешивания (по объему)
покрытиями смола .................................. 1 часть
• Легко наносится с помощью автоматического отвердитель........................ 1 часть
распылительного оборудования
• Отношение для смешивания 1:1 Механизм отверждения ....... Выделение растворителя и
• Не содержит хроматов и свинца реакция между компонентами
• Соответствует Британским нормам EPA для
конструкционных грунтовок Толщина сухой пленки ......... 15-25 мкм на слой
Рекомендуемые системы
ВЕРХНИЕ ПОКРЫТИЯ – соответствующими верхними покрытиями
являются эпоксидные смолы, алкиды, эпоксидные смолы с Информация по нанесению
каменноугольным дегтем, полиуретаны фирмы PPG. До нанесения
верхнего покрытия, грунтованная поверхность должна быть Поверхность ............................. сталь, очищенная с
очищена и свободна от загрязнений, пыли и инородных веществ; помощьюабразивной струйной
особое внимание необходимо обратить на поврежденные участки. обработки
Поврежденные участки можно восстановить с помощью Amercoat
139 после очистки путем локальной струйной очистки или Методы нанесения................... безвоздушный или обычный
механической очистки методами с применением проволочных пульверизатор
щеток, в зависимости от условий эксплуатации. См. также
требования и рекомендации, которые приводятся в данных о Условия окружающей среды
продукте для промежуточных и верхних покрытий, которые будут (во время нанесения и сушки)
использованы. Для получения конкретных рекомендаций Температура воздуха ........ 5 до 50ºС 41 до 122ºF
обратитесь к представителю компании PPG. Температура поверхности. 5 до 60ºС 41 до 140ºF
Транспортировка
Product Data/
Application Instructions Physical Data
Finish ..................................... low sheen
• Rapid drying two pack epoxy zinc phosphate Colour .................................... red oxide, light grey, grey, buff and
primer off white.
• EPA compliant (1998) in accordance with Components .......................... 2
PG6/23
• High build, high solids and low VOC Mixing ratio (by volume)
resin .................................... 6.2 parts
• Corrosion inhibiting cure ..................................... 1 part
• Excellent adhesion to blast cleaned steel
• Excellent abrasion and impact resistance Curing mechanism ................ solvent release and reaction
between components. Effective
• No maximum overcoating restrictions cure down to 5°C/41ºF
Flash points
(Closed Cup)........................ ºC ºF
resin .................................... 24 75
cure ..................................... 24 75
Amercoat 18 ....................... 25 77
Amercoat 12 cleaner............ 24 75
Surface preparation
Surfaces must firstly be thoroughly cleaned of all Application Data
contaminants such as dust, dirt, oil, grease and salts. Substrate ............................... blasted steel
Then abrasive blast clean to ISO 8501-1, Sa21/2. The
blast profile achieved should be within the range 50 to Application methods .............. airless spray, brush or roller
100 microns. Priming should occur before Potlife (at 20°C/68ºF) ............ 2 hours
degradation of the surface takes place. If oxidation
occurs then the surface should be re-prepared. The Induction time (at 20°C/68ºF) not applicable
surface must be dry and free of dust, salts, grease Environmental conditions
and other contaminants immediately before coating.
Steelguard 3290 should only be applied within the limits of
temperature and humidity set out below.
Mixing Relative humidity: ................ Up to 90%
Surface temperature: ........... Minimum 2°C/36ºF
Stir the resin component thoroughly, then add the ............................................. Maximum 40°C/104ºF
cure and continue mixing until the product is uniform
throughout. A powerful mixer should be used. The surface temperature must also be at least 3°C/5ºF above the
dew point during application.
As with most coatings early contact with water can result in water
Application spotting damage. Care should be taken to protect the coating
AIRLESS SPRAY: Use standard airless spray during the early stages of cure to prevent water marking.
equipment capable of producing a minimum pressure
at the tip of 2800 psi (200 kg/cm²). Tip size range 15- Drying characteristics ºC/ºF
21 thou (0.38-0.53mm). Adjustments to pressure and Temperature 5/41 10/50 20/68
tip size/angle may be necessary to obtain spray
characteristics required for specific substrate Touch dry 4 hours 2 hours 1 hours
configurations.
BRUSH/ROLLER: Application by these methods Hard dry 8 hours 5 hours
1
2 /2 hours
should be limited to small areas only such as repairs
and when stripe coating. Apply evenly using a clean, Overcoating 1
8 hours 5 hours 2 /2 hours
(minimum)
well-loaded brush or roller. With this application more
Overcoating - - -
than one coat may be necessary to achieve the (maximum)
required dry film thickness
This product will cure down to 0°C/32ºF, however drying
times will be extended.
Application procedure
1. Clean the equipment with the recommended cleaning Shipping Data
solvent before use.
Packaging............................... 20 litres in two part units
2. Stir the resin component thoroughly, then add the cure resin .................................... 17.23 l in 20 l can
and continue mixing until the product is uniform cure ..................................... 2.77 l in 5 l can
throughout. A powerful mixer should be used. Thinning
is not required. Shipping weight (approx)
3. For airless spray, apply a wet even coat in parallel resin .................................... . 31 kg
passes. Overlap each pass by 50% to avoid bare areas, cure ..................................... 4 kg
pinholes or holidays. Shelf life ................................. 1 year from shipment date or as
4. Give special attention to welds, rough spots, sharp indicated on label when stored
edges and corners, rivets, bolts, etc. indoors in unopened, original
5. Application at 104µm wet film thickness will normally containers at 5 to 40°C (41 to
provide 75µm dry film. 104ºF).
6. Check thickness of dry coating with a non-destructive
dry film thickness gauge, such as Mikrotest or
Elcometer. If less than specified thickness, apply
additional material as needed.
7. Small damaged or bare areas and random pinholes or
holidays can be touched up by brush. Repair larger
areas either by spray, brush or roller using Steelguard
3290.
8. In confined areas ventilate with clean air during
application and drying. The humidity should be
maintained below 90% and the temperature such that
moisture condensation will not form on the surface.
9. Clean all equipment with fresh, clean solvent
immediately after use.
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Ɏɢɧɢɲɧɵɟɩɨɤɪɵɬɢɹ
Amercoat 220G
Amercoat 220 LS
Amercoat 450E
Amercoat 2136
Steelguard 2458
Amercoat 4310
PSX 700
> START
We Know...
Fire Protection
Coatings
Amercoat
Amercoat 220G
Водоразбавляемое акриловое отделочное покрытие
Описание материала/
Инструкция по нанесению
Физические характеристики
Подготовка поверхности
Покрытие наносится на поверхности, Информация по нанесению
подготовленные в стандартном порядке с Субстрат................................ загрунтованная поверхность
помощью водоразбавляемой грунтовки Amercoat
148. Система подготовки грунта и поверхности Метод нанесения .................. безвоздушный распылитель,
кисть, валик
будет завесить от типа субстрата и его состояния.
За конкретной технической информацией
обращайтесь в местное представительство
Жизнеспособность (при 20°C/68ºF) нет данных
компании PPG.
Перед нанесением покрытия убедитесь в том, что Условия окружающей среды
поверхность очищена от грязи, солей, смазки и
Нанесение состава Amercoat 220 допусчкается только при
прочих загрязнителей. соблюдении при соблюдении изложенных ниже режимов
температуры и влажности.
Относительная влажность: до 90%
Приготовление смеси Температура обрабатываемой
Тщательно размешайте краску до однородного поверхности:
состояния с помощью мощной смесительной не менее: 5°C/41ºF
не более: 40°C/104ºF
установки.Stir thoroughly before use until the product
is uniform throughout. Для предотвращения конденсации влаги во время нанесения
покрытия, температура поверхности должна быть выше точки
росы не менее чем на 3°C/5ºF.
Порядок нанесения покрытия
Условия сушки
БЕЗВОЗДУШНЫЙ РАСПЫЛИТЕЛЬ – распылитель
с размером сопла 15 - 19 тычячн (0,38-0,48 мм). Температура ºC/ºF 10/50 20/68 30/86
Давление на 2800 фунт/дюйм2 (200 кг/см²).
Сухо на ощупь 90 мин 45 мин 20 мин
КИСТЬ - Наносите краску плотным ровным слоем,
используя чистую кисть подходящего размера.
Сухо по всей 4ч 2ч 1ч
Будьте внимательны, не выходите за пределы толщине
зон, предназначенной для окраски кистью.
ВАЛИК – Наносите краску плотным ровным слоем, Время до нанесения 4ч 2ч 1ч
используя чистую валик подходящего размера. покрывного
материала
Будьте внимательны, не выходите за пределы (минимально)
зон, предназначенной для окраски валиком. Для у
устранения эффекта пузырения пользуйтесь Время до нанесения Максимальное время нанесе-
покрывного ния Amercoat 220 в качестве
кистью. материала покрывного материала по идентичному
(максимально) покрытию не определено
Условия продажи
Любые сделки, совершаемые компанией,
осуществляются в соответствии с установленными
сроками и условиями продажи.
Описание материала/
Инструкция по нанесению Физические характеристики
Внешний вид ......................... полуглянец
• Одноупаковочное водоразбавляемое Цвет ....................................... RAL и BS*
акриловое покрытие
Число компонентов............... 1
• Быстросохнущее стойкое финишное
покрытие Коэффициент смешения
• Может наноситься при температурах до 5ºC (по объему) ........................... нет данных
• Исключительно устойчиво к атмосферным Механизм отверждения ....... естественная сушка
воздействиям
• Высоко ударопрочно и эластично Массовая доля нелетучих
веществ ................................. 42 % (расчетное)
• Устойчиво к загрязнениям и царапинам
• Наносится кистью, валиком или Летучие органические
пульверизатором соединения**
EC SED 1999/13/EC ........... 16 g/kg (20g/l)
• Быстро и легко очищается UK PG6/23(92) Appendix 3 . 20 g/l (0.2 lbs/gal)
• Практически не имеет запаха и не выделяет
летучих органических соединений
Толщина сухой пленки ......... 50 – 75 мкм на слой
2 – 3 тыс на слой
Схемы покрытий с применением
материала Amercoat 220LS Количество слоев ................. 1**
Amercoat 220 LS – водоразбавляемая акриловая Расчетная укрывистость
эмаль, которая может применяться для 2
При ТСП 50 мкм/ 2 тыс ...... 8,4 м /л
2
342 фут /галлон
2 2
металлических конструкций, покрытых При ТСП 75 мкм/ 3 тыс ...... 5,67 м /л 228 фут /галлон
вспенивающимися покрытиями компании PPG или Стойкость к
совместимыми грунтовками, как по внутренней, воздействию температур °C °F
так и внешней поверхности зданий. Покрытие продолжительное............... 93 200
идеально для непосредственного применения на нерегулярное...................... 120 250
подготовленном бетоне или кладке, а также
поверх прочных старых покрытий. Применяется в Температуры вспышки ......... °C °F
качестве верхнего слоя с органическими и Amercoat 220LS .................. >100 > 200
неорганическими цинксодер-жащими грунтами для Разбавитель.......................... Вода
ремонта и строительства резервуаров (наружные
поверхности) и стальных конструкций. Очиститель............................ Вода или водный раствор с
присадками
Основные характеристики
Amercoat 220 LS обеспечивает создание внешне Информация по нанесению
привлекательного, эластичного, очищаемого слоя с легким
Субстрат................................ Подготовленная сталь, загрунто-
глянцем, устойчивое к растрескиванию, шелушению и
ванная составом вспениваемым
ударам. Он сохраняет цвет и блеск значительно лучше,
PPG или другим подходящим
чем традиционные алкидные или хлоркаучуковые верхние грунтом, подготовленный бетон,
покрытия. Amercoat 220 LS может применяться вместо дерево, сухая кладка
алкидных и хлоркаучуковых покрытий на основе
растворителей, что позволит значительного уменьшить Подготовка поверхности ...... За рекомендациями по грунту и
выделение органических веществ. промежуточному слою обра-
щаться к перечню типовых схем
Условия продажи
Любые сделки, совершаемые компанией,
осуществляются в соответствии с установленными
сроками и условиями продажи.
• Высокоглянцевый покрывной материал, стойкий Цвет .......................................... см. перечень стандартных цветов
к воздействию ультрафиолетового излучения и PPG *
выполняющий функцию глянцевого или Число компонентов.................. 2
полуглянцевого финишного покрытия
Коэффициент смешения
• Обладает высокой стойкостью к атмосферному
(по объему) ............................. смола : отвердитель = 4:1
воздействию при исключительной стабильности
цвета и блеска Плотность
• Стойкость в морских и агрессивных средах Amercoat 450E (глянец) ........ 1,37 (белый, смешанный продукт)
Amercoat 450E (п/глянец) ..... 1,44 (белый, смешанный продукт)
• Грязеустойчиво, легко очищается
• Твердое, прочное, гибкое покрытие, устойчивое Механизм отверждения........... испарение растворителя и
взаимодействие компонентов
к истиранию
• Отверждается в широком диапазоне температур Массовая доля нелетучих
веществ ................................... 60+3 % (ISO 3233) **
• Может перекрываться дополнительным слоем
• покрытие одобрено к использованиею по Летучие органические
результатам испытаний BBA HAPAS и компании соединения***
EC SED 1999/13/EC .............. 303 g/kg (413 g/l)
Network Rail UK PG6/23(92) Appendix 3 .... 350 g/l (2.9 lbs/gal)
Область применения Толщина сухой пленки ............ 40-75 мкм (1,36 - 3 милс)
Высокопрочное финишное покрытие, используемое в широком 50 -125 мкм (2-5 милс)
спектре внешних условий для анти-коррозионной защиты
общих металлоконструкций, таких как мосты, морские Количество слоев .................... 1****
сооружения, объекты нефтеперерабатывающей
Расчетная укрывистость ......... м2/л фут2/галлон
промышленности и нефтяные резервуары, химические заводы при ТСП 40 мкм/ 1,5 тыс ....... 15.0 557
и электростанции, а также прочие объекты промышленности, при ТСП 70 мкм/ 2 тыс .......... 8.6 318
работающие в жестких условиях.
Стойкость к
Типовые схемы покрытий с применением воздействию температур 120 °C 250 °F
материала Amercoat 450E Температуры вспышки °C °F
Промежуточный Финишное Amercoat 450E отвердитель.... 25 77
Грунт
слой покрытие Amercoat 450E смола............ 30 86
Dimetcote Amercoat 385 или Amercoat 450E Смесь ..................................... 30 86
Amercoat 383H Amercoat 920 ......................... 24 73
Серия Amercoat Amercoat 385 или Amercoat 450E Amercoat 12 ........................... 24 73
68 Amercoat 383H
Разбавитель............................. Amercoat 920
Amercoat 385 PA Amercoat 450E
Amercoat 235 Очиститель............................... Amercoat 12
Amercoat 240 * Резервуары и другие большие конструкции, покрытые ранее
Amercoat 370 контрастирующим по цвету грунтом или промежуточным слоем, могут
Amercoat 385 потребовать нанесения двух слоев состава Amercoat 450E с тем, чтобы
конечное покрытие было равномерным. При использовании одного слоя
Серия Amerlock Amercoat 450E Amercoat 450E светлого цвета необходимо применять грунты и
промежуточные покрытия светлых оттенков.
Алюминиевое покрытие поставляется только полуматового оттенка,
устойчивое к коррозии
Сертификаты и испытания
Amercoat 450E одобрен к использованию и внесен в реестр ** Содержание нелетучих веществ замерено в соответствии со стандартом
BBA HAPAS "Справочник по сертификации на дорожные и ISO 3233 и действующими дополнениями. Незначительное отклонение (около
мостовые конструкции 05/H116" (Спецификация дорожного ± 3%) может быть вызвано изменчивостью условий испытаний и цвета
покрытия.
управления: п. 168 - для глянцевого покрытия, п. 169 - для *** Содержание летучих органических соединений приведено согласно
полуглянцевого). Также материал внесен в спецификацию UK директиве ЕС 1999/13/EC , на основе теоретических расчетов, и согласно
Network Rail RT98 пункт 7.3.1. требованиям UK PG6/23(92) Приложение 3, на основе практических данных.
****При использовании кисти или валика может возникнуть необходимость в
нанесении дополнительных слоев покрытия для достижения требуемой
толщины покрытия.
Описание материала/
Инструкция по нанесению
• Функциональное толстослойное финишное
покрытие Физические характеристики
• Наносится непосредственно на Внешний вид в
оцинкованную сталь сухом состоянии .................. легкий глянец, металлический
• Многократно успешно применялось на блеск или полуглянец
практике Цвет ....................................... черный, промежуточный серый,
• Материал одноупаковочный серебристо-серый, светло-
• Совместим с большинством старых серебряный
покрытий Число компонентов............... 1
• Не приводит к возникновению
Механизм отверждения ....... испарение растворителя
поверхностного напряжения
Доля нелетучих веществ ..... 53±2%
Смешение
Тщательно размешайте состав до полной
однородности материала
Оборудование по нанесению
Рекомендованное ниже оборудование, может быть
заменено аналогичными приспособлениями других
производителей, если таковые отвечают существующим
условиям нанесения покрытия. В целях обеспечения
надлежащих характеристик распыления может
понадобиться дополнительная регулировка рабочего
давления и размера сопла пульверизатора.
КИСТЬ/ВАЛИК – наносите состав ровным слоем с
помощью чистой кисти или валика. Не пытайтесь
смазать или разровнять влажный слой после
нанесения.
БЕЗВОЗДУШНЫЙ РАСПЫЛИТЕЛЬ – Состав может
быть разжижен с помощью соответствующего
разбавителя до 10% по объему. Размер насадки -
15 - 18 милс (0,38 - 0.46мм).
Выходное давление: 2800 фунтов/м2 (200 кг/см2).
Порядок нанесения
1. Перед использованием промойте инструмент в Транспортировка
рекомендованном очистителе.
Фасовка ................................. 5 л (1,32 галлона)
2. Тщательно размешайте содержимое ведра до
однородного состояния с помощью мощной Отгрузочная масса ............... около 8,5 кг
смесительной установки.
3. При необходимости допускается применение Срок годности ....................... 1 год со дня отгрузки при
разбавителя, массовая доля которого не должна хранении внутри закрытого
помещения в нераспечатанной,
превышать 10 %.
оригинальной таре при
4. Во время проведения окрасочных работ температуре 5 - 40 C.
продолжайте помешивать состав. Влажное покрытие (41 - 104°F)
наносите параллельными проходами. Во избежание
неокрашенности отдельных участков, наколов или
недостаточной толщины покрытия каждый
последующий проход должен перекрывать
предыдущий на 50%.
5. Сварные швы, шероховатости, заострённые кромки
и углы, заклепки, болты, и т.п. покрываются двойным
слоем.
6. При толщине мокрой пленки 142 мкм (5,7 милс)
сухая пленка обычно составляет 75 мкм (3 милс).
7. Проверьте толщину сухой пленки средствами, не
нарушающими целостность покрытия (например,
приборами "Mikrotest" или "Elcometer"). По необхо-
димости нанесите дополнительный слой материала.
8. Небольшие дефекты поверхности или
неокрашенности, немногочисленные наколы или
недостаточная толщина покрытия отдельных
участков могут быть устранены с помощью кисти.
Более серьезные недостатки устраняются
посредством распылителя.
9. При работе в закрытых помещениях обеспечьте
необходимую вентиляцию на период нанесения
покрытия и его сушки вплоть до полного испарения
растворителя. Температура и влажность воздуха,
используемого для вентиляции, должна
устанавливаться так, чтобы не допустить
конденсацию влаги на поверхности.
10. Промойте инвентарь в рекомендованном очистителе
после использования или, как минимум, в конце
каждого рабочего дня или смены
Условия продажи
Любые сделки, совершаемые компанией,
осуществляются в соответствии с установленными
сроками и условиями продажи.
Описание материала/
Инструкция по нанесению Физические характеристики
Внешний вид после сушки ... полуглянец
• Финишное покрытие по вспениваемой Цвет ....................................... согласно каталогам RAL и BS *
системе Steelguard, соотвтетсвующее
Требованиям Управления по охране Число компонентов............... 1
окружающей среды (1998), Механизм отверждения ....... испарение растворителя
• Толстослойное
Массовая доля нелетучих
• Может использоваться на конструкциях Ане веществ ................................. 45 ± 2% (ISO 3233)*
помещений
• Одноупаковочное Летучие органические
соединения**
• Долговременное сохранение цвета EC SED 1999/13/EC ........... 430 g/kg (532 g/l)
UK PG6/23(92) Appendix 3 . 499 g/l
Температуры вспышки
(при закрытом тигле) ............ °C ºF
Steelguard 2458 .................. 24 75
Amercoat 65 ........................ 24 75
Очиститель............................ Amercoat 65
Подготовка поверхности
Непосредственно перед нанесением поверхность Информация по нанесению
должна быть очищена от пыли, солей, масел и Субстрат................................ Сталь, покрытая составом
других загрязнителей и высушена. Steelguard FM 549/ Steelguard FM
550/ Steelguard FM560
Очиститель............................ Amercoat 65
Порядок нанесения
1. Перед использованием промойте инструмент в Транспортировка
рекомендованном очистителе.
Фасовка ............................ 20 л
2. Тщательно размешайте до однородного состояния с
помощью мощной смесительной установки. Отгрузочная масса .......... около 28 кг
3. При безвоздушном нанесении использование
растворителей, как правиле, не требуется Срок годности .................. 1 год со дня отгрузки при
Во время проведения окрасочных работ хранении внутри закрытого
продолжайте помешивать состав. Влажное покрытие помещения в
наносите параллельными проходами. Во избежание нераспечатанной,
неокрашенности отдельных участков, наколов или оригинальной таре при
недостаточной толщины покрытия каждый температуре 5 - 40 C.
последующий проход должен перекрывать (41 - 104°F)
предыдущий на 50%.
4. Сварные швы, шероховатости, заострённые кромки
и углы, заклепки, болты, и т.п. покрываются
двойным слоем.
5. При толщине мокрой пленки 167 мкм сухая пленка
обычно составляет 75 мкм.
Проверьте толщину сухой пленки средствами, не
нарушающими целостность покрытия (например,
приборами "Mikrotest" или "Elcometer"). По необхо-
димости нанесите дополнительный слой материала.
6. Небольшие дефекты поверхности или
неокрашенности, немногочисленные наколы или
недостаточная толщина покрытия отдельных
участков могут быть устранены с помощью кисти.
Более серьезные недостатки устраняются
посредством распылителя.
7. При работе в закрытых помещениях обеспечьте
необходимую вентиляцию на период нанесения
покрытия и его сушки вплоть до полного испарения
растворителя. Температура и влажность воздуха,
используемого для вентиляции, должна
устанавливаться так, чтобы не допустить
конденсацию влаги на поверхности.
8. Промойте инвентарь в рекомендованном
очистителе после использования или, как минимум,
в конце каждого рабочего дня или смены
Условия продажи
Любые сделки, совершаемые компанией,
осуществляются в соответствии с установленными
сроками и условиями продажи.
Mixing
Stir thoroughly before use until the product is uniform
throughout.
Application Methods
AIRLESS SPRAY: Use standard airless spray Application Data
equipment capable of producing a minimum pressure Substrate ................................ Primed substrates
at the tip of 2800 psi (200 kg/cm²). Tip size range 13-
17 thou (0.33-0.43mm). Adjustments to pressure and Application methods ............... airless or conventional spray, brush
or roller
tip size/angle may be necessary to obtain spray
characteristics required for specific substrate Potlife (at 20°C/68ºF) ............ N/A
configurations.
Environmental Conditions
CONVENTIONAL SPRAY: Use standard industrial Amercoat 4310 should only be applied within the limits of
equipment. Thinning with the recommended thinner temperature and humidity set out below.
may be necessary to facilitate application. Relative humidity: ................ up to 90%
BRUSH/ROLLER: Apply evenly using a clean, well- Surface temperature: ........... minimum: 5°C/41ºF
............................................. maximum: 40°C/104ºF
loaded brush or roller. With this application more than
one coat may be necessary to achieve the required dry The surface temperature must also be at least 3°C/5ºF above dew
film thickness. point.
NOTE: drying and curing times are dependent on air and steel
temperature, applied film thickness, ventilation and other
environmental conditions. Times are shorter at higher temperatures
and longer at lower temperatures
Application procedure
1. Flush equipment with recommended cleaner Shipping Data
before use. Pack size ............................... 5 litres
2. Stir the contents of the can to an even
consistency. Shipping weight ...................... approx. 6 kg
3. Thinning is normally not required for airless spray. Shelf life ................................. 1 year from shipment date or as
4. Stir during application to maintain uniformity of indicated on label when stored
material. Apply a wet even coat in parallel passes. indoors in unopened, original
containers at 5 to 40°C (41 to
Overlap each pass 50% to avoid bare areas, 104ºF).
pinholes or holidays.
5. Double coat all rough spots, sharp edges and
corners, rivets, bolts, etc.
6. Application at 85 µm wet film thickness will
normally provide 40 µm dry film.
7. Check thickness of dry coating with a non-
destructive dry film thickness gauge, such as
Mikrotest or Elcometer. If less than specified
thickness, apply additional material as needed.
8. Small damaged or bare areas and random
pinholes or holidays can be touched up by brush.
Repair larger areas by spray.
9. In confined areas ventilate with clean air during
application and drying until all solvents are
removed. Temperature and humidity of ventilating
air must be such that moisture condensation will
not form on surface.
10.Clean all equipment with recommended cleaner
immediately after use or at least at the end of each
working day or shift
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
Информация по нанесению
Рекомендации по химической устойчивости
Среда Брызги и проливы Дымы и воздействие Поверхность.......................... подготовленная сталь, бетон не
погодных условий железисто металлы
Кислотная Отличная Отличная
Щелочная Отличная Отличная Методы нанесения ............... безвоздушный или обычный
Растворы соли пульверизатор, кисть или валик*
кислотные Отличная Отличная
нейтральные Отличная Отличная Жизнеспособность, ºC/ºF ..... 30/86 20/68 10/50|
щелочные Отличная Отличная 1.5 4 6.5 часы
Пресная вода Отличная Отличная
Растворители Отличная Отличная Жизнеспособность зависит от температуры и количества
Нефтепродукты Отличная Отличная смешанных материалов.
Данные о нанесении
Подобно всем прочим покрытиям с высокими
эксплуатационными свойствами, данный продукт следует
наносить в соответствии с рекомендациями для обеспечения
максимальных эксплуатационных характеристик.
Подготовка поверхности
СТАЛЬ/БЕТОН – выполняйте подготовку поверхности в
соответствии с инструкциями по нанесению применительно к
конкретному используемому грунтовочному материалу.
Проследите, чтобы грунтовка была чистой и сухой при
нанесении состава PSX 700.
СУЩЕСТВУЮЩИЕ ПОКРЫТИЯ – PSX 700 может
использоваться поверх некоторые типов надлежаще
очищенных плотно прилегающих покрытий. Для получения
конкретных рекомендаций обратитесь к представителю
компании PPG.
Тепловое отверждение
Дайте возможность материалу PSX 700 высохнуть на ощупь,
прежде чем на него будут воздействовать температуры
0
отверждения, превышающие 60 С/140ºF.
Метод нанесения
1. Перед использованием промойте инструмент
очистителем или составом Amercoat 12.
2. Перемешайте материал до однородного состояния.
3. Добавьте отвердитель PSX 700 FD в смолу PSX 700.
Тщательно размешайте до получения однородной смеси.
4. При необходимости восстановления рабочих свойств
материала, добавьте растворитель порекомендовано
Разбавьте до 10% по объему.
5. Влажное покрытие наносите параллельными
проходами. Во избежание неокрашенности
отдельных участков, наколов или недостаточной
толщины покрытия каждый последующий проход
должен перекрывать предыдущий на 50%.При
необходимости проведите нанесите материал "крест-
накрест" под соответствующим углом к первому проходу.
6. Нанесение кистью и/или валиком потребует двух
слоев для того, чтобы толщина сухой пленки была
до 175 мкм. Для некоторых текстур поверхности
типовыми являются нанесение кистью или валиком.
7. При нанесении PSX 700 непосредственно на
Dimetcote, может потребоваться техника нанесения
типа "тонкий слой/полновесный слой" для
минимизации возможного пузырения. Разбавьте
PSX 700 составом Amercoat 900 до
Условия продажи
Любые сделки, совершаемые компанией,
осуществляются в соответствии с установленными
сроками и условиями продажи.