Sort Specifications No Name Specifications
This cover protects the batteries and the registration
Password 4-12 digits (Up to 4 can be registered) 1 Battery cover
button.
RF key It can register within 30 2 Interlocking pack Receive (CDL-447, optional)
Opening method 3 Registration button It is used to register or change password or smart key
Fingerprint It can register within 100 It is attached to the side of the door and closes or locks the
USER MANUAL Wallpad interlock Optional (CDL-447)
4 Mortise
Dead bolt
door.
5 It locks the door by locking it on the door frame.
Rated voltage DC 6V LR6 1.5V AA sized alkaline batteries 8 (Square locking type)
6 Latch bolt It serves to keep the door shaken
Emergency power DC 9V Alkaline batteries 8 (Separate purchase) 7 Alkalina AA battery It is a power source that operates the door lock.
Durable Door lock without worry about A/S CDL-210LSKF(Fire-proof, temperature-sensitive form, key primary keylock / F-T-K-M) It can be used to lock the door so that it can not be opened
Type of product 8 Double lock button outside,such as during nighttime hours that require
CDL-210LSNF(Fire-proof, temperature-sensitive form, non-key, primary keylock / F-T-NK-M)
attention.
Durable body of metal High temperature sensing Temperature sensor type 60+-10 dgrees 9 Indoor handle It is used to open or close the door indoors.
재질 Out body AL,ZN,ABS,PC
Auto lock/rewind/double lock function material
In body AL,ZN,ABS,PC
Use of 3D touch and imaginary function to secure password Sort Using frequency
Number of Modulation
Antenna power
channels format
Password/Smart key/Fingerprint can be registered multiple RFID 13.56Mhz 1 ASK 93.5dBu/under m@ 10m
Wireless devices for
afety systems 447.275Mhz 1 FSK 10mW/under
Multi-level volume control / Selectable silence function (optional)
Intuitive registration UI Outbody Inbody Mortise & Stricker(Option1) Big Mortise & Stricker(Option2) Screw
How to register and change password How to register the linker (optional) How to set and dismiss 3D touch
Be sure to register your password with the door open. 1. Press 2. Press [4]button in the number
1. Press 2. Press [2]button in the number [registration] button plate of outdoor side 1. Enter password 2. Press the [#] button twice in
[registration] button Touch the outdoor succession, then press
plate of outdoor side
license plate to
the 0 button.
turn on the LED
Beep and enter the
Beep Open the battery cover and
registered password.
Open the battery cover and press [registration]button
press [registration]button
3. Enter new password 3. Press [Registration]button
3. Press the [Register] or [OP / CL] button on the linker
After entering the new password(4~12 digits), When you press the [Registration] button on the outdoor
After pressing the front door button of the wall pad(video phone), side body, the 3D touch function is turned on or off.
press * button and the confirmation tone sounds
press the [Registration] or [OP / CL] button of the interlocker Beep
and registration is completed. Press the * button - Set tone: Piriricic
when the standby mode is canceled. Open the battery cover and
once more to end registration. - Off sound: Piric
press the [Registration] button.
Cautions
How to delete fingerprint, smart key, linker Ex) When 1 is long pressed: It is recognized as a virtual
number other than 1.
1. If you register a new password, the existing password
will be automatically deleted. 1. Press 2. Press number in the number plate 2. Combined with the imaginary function of this product,
2. Do not use consecutive numbers when registering your [registration] button - Smart key deletion: No 7 button
password security is further strengthened.
3. You can set each number and you can check that the
password.
- Deleting the interlock: No 8 button lamp blinks when you press for more than 1 second.
How to register Smart key - Delete fingerprint: No 9 button 4. 3D touch mode is turned off at the factory.
Beep
When registering or re-registering a smart key, you must register Open the battery cover and
all the smart keys you have at once. Also registered smart keys are press [registration]button Cautions
door lock only. It may not work when used with other products.
1. When the 3D touch mode is released, the password is
1. Press 2. Press [3]button in the number 3. Press #button reset to "1234".
[registration] button plate of outdoor side 2. In case of master registration / deletion, fire / accident, etc.,
Press and hold the [#] button for 5 seconds to delete it is recognized as normal number mode.
Reference Reference
1. When you press [double lock] button in manual lock 1. If dual authentication mode is activated, Password +
Card should be confirmed to open to door.
Battery Replacement Alert
mode, you will hear a "beep" buzzer sound when the door
is locked and inform you that the door is lockedv. (door open by BLE keeps available.)
If battery alert light is on on number plate or beep sounds ring, battery has to
2. If registration authentication mode is activated,
be replaced. All batteries must be replaced with new one at once.
first authentication by existing password should be done
Factory default mode is completed with beep sound. Flicking ALL LEDs - Anti-mischief alert and 1 minute pause
High Temperture Alarm Flicking LED number 2 - Error on password, card, fingerprint set
Anti-mischief alert and 1 minute pause Flicking LED number 6 - Unregistered password, card, fingerprint
Emergency Power Flicking LED number 7 - Already registered address
If unregistered [password], [smartkey], [fingerprint] keeps used more than 5 times
When door can not be opened due to fully discharged battery. Flicking LED number 8 - Fire Alarm
continuously, freeze operation for 1 minute with alert sound.
Flicking LED number 9 - Dual lock from Indoor unit
1. Contact the terminals of 9V battery to emergency power outlet
Press [Password] and [ * ] to open the door while contacting Flicking LED number 0 - Malfunction of fingerprint module
terminals of 9V battery to emergency power outlet. Try 5 times
in a row?? Summary of how to use
Function Default
Fingerprint registration [Registration] button ⇒ [1] button ⇒ Fingerprint registration 4 times ⇒ [Registration] button
Reference Delete all fingerprints [Registration] button ⇒ [9] button ⇒ [#] button More than 5 seconds
Password change 1234 [Registration] button ⇒ [2] button ⇒ Password to register ⇒ [*] button ⇒ [*] button
9V emergency battery 1. To deactivate alert sound, open the door from indoor body
Card registration None [Registration] button ⇒ [3] button ⇒ Card (tag) recognition (Continuous registration) ⇒ [Registration] button
(sold separately) handle Delete all card [Registration] button ⇒ [7] button ⇒ [#] button More than 5 seconds
2. If mechanical key is available, deactivate alert sound by key Interlocking registration None [Registration] button ⇒ [4] button ⇒ Remote control [OP / CL]⇒ [Registration] button
When door is not opened due to malfunction. Deadbolt Jam alert Close the door indoors
Auto lock: Auto lock when the door is closed
Manual Locking: Press the [Internal Dual Locking] button
Password: LED of window number LED ON ⇒ Enter password ⇒ Press [*] button
Open the door outdoors Card: Card contact with card recognition
Open the cover on the handle of the outdoor body When deadbolt is jammed during door Emergency key: Rotate after inserting emergency key into Emergency key insertion part
Auto lock: Auto lock when the door is closed
If you insert the emergency key and turn to the left or right open/close, alert sound of Close the door outdoors
Manual locking: Touch the license plate of the window for 2 seconds
You can release the lock status. bee bee bee bee” rings 3 times. Auto lock setting Enter the password ⇒ Press the [#] [#] button ⇒ Press the [4] button ⇒ Press the [Registration] button
Automatic locking
Manual lock setting Enter the password ⇒ Press the [#] [#] button ⇒ Press the [7] button ⇒ Press the [Registration] button
Enter the password ⇒ Press the [#] [#] button ⇒ Press the [1] button (Individual authentication / Dual authentication)
Set dual authenitication mode Release
⇒ Click the [Registration] button
Set registration Enter the password ⇒ Press the [#] [#] button ⇒ Press the [8] button (General registration / double registration)
Release
authenitication mode ⇒ Click the [Registration] button
Enter the password ⇒ Press the [#] [#] button ⇒ Press the [0] button ⇒ Press the [Registration] button
3D touch authenitication mode Release