You are on page 1of 12
Ve VOKSEL KABEL Type and Description Type and Description brad) ‘Type and Description Single Core Cable Cu or Al Conductor, XLPE Insulated, Copper Tape or Wires Screened and PE/PVC Sheathed Type: N2XSY,N2XS2Y NA2XSY,NA2XS2Y Specification Size Rated Voltage Application SPINA3-5-3 Cu.35~400mm? 3.4/6kV(Um7.2)kV. Indoors, Ouideors, 1EC60502-2 AL.50 ~500mm? upto Undergroundand 18/30kV(Um36)kV Cable rack Single Core Cable Cu or Al Conductor, XLPE Insulated, Concentric Conductor Screened and PE/PVC Sheathed Type: N2XCY, N2XC2Y NA2XCY, NA2XC2Y Specification Size Rated Voltage Application SPIN43-5-5 Cu35~400mm? 3.6/6K¥(Um7.2)kV Indoors, Outdoors, IEC 60502-2 AL.50~500mm? upto Underground and 18/30kV(Um36)kV Cable rack Overhead Twisted Cable Aluminium Conductor, XLPE Insulated, Copper Tape or Wires screened and PVC Sheathed Type: NFA2XSY-T Specification Size Rated Voltage Application Phase: SPIN 43-5-2 ‘& 3 12/20 (24)kV. Overhead jeceoson: || $x00.-240)men upto Instollotion 1x50mmand ‘18/30 (Um36) kV 1x95 mm? Underground Twisted Cable Cuor Al Conductor, XLPE Insulated, Copper Tape or Wires Screened and PVC Sheathed Type: NF2XSY, NF2XS2Y NFA2XSY, NFA2XS2Y Specification Size Rated Voltage Application SPLNAB-5-1 3x(35~300) mm? 12/20(24)kv Indoors, Outdoors lec 40502.2 ae ‘and Underground 18/98 (Um 34) kV VOKSEL KABEL, Optical Fiber Cable For Duct Installation Specification Application STELK-015 The duct optical cable is with loose jube core, iis suitable tothe system requiring more optical cob) Thefibers are accommodoatedinjell filled tubes: ‘excess{engih. lfflome retardant characteristicisrec special materiol con be applied asthe outer Sheath ‘Type and Description Optical Fiber Cable for Direct Buried Installation Specification Application STELK-016 The optical fiber cable with o corrugated steel tape ‘orsteel wire armouring far protection. They con used. asdirect buried, antibolistic, antirodent, antfitermite cables whenever mechanical strengthisrequired. Thiscable is loose tube core Optical Fiber Cable ADSS Type Specification Application Otherspecification Thisisoptical ADSS type (il Didleerie el Soppertnal ‘are available upon with Aramid Yarn for peripheral strength member. Thiscable request must havenon-metallicand high tensile strength. They or= used asAeriol Application, antirodent, onfibalistic, ont {ermite cablewhenever mechanical strength, anf elect induction and lighting effect: Optical Fiber Cable for Aerial Installation Specification STELK-017 “hiss optical bercoble intergrated wiha messengerwire foraerialinstollation. This cable isloose tube core. if cemouringsnecesaryio preventdamoged by rodents, insect {and shot guns, peripheral high sirenaih yarncon be applied. 10 VE VOKSEL KABEL Type and Description ‘Type and Description 1. Jelly Filled Non Armored Cable Polyethylene Insulated Jelly Filled, AluminiumScreened, Polyethylene Sheathed Specification 1. STEL-K-008 iS110618-82) pele Botton ppp tion Beason pt 2 $59/POSTEL/ES 12h Booed bcos 1, Duct Cable Polyethylene Insulated Aluminium Screened and Polyethylene sheathed (Dry Cable/Non Jelly Filled) Specification Size 1. STEL-K-009 (si10819 82) BOP te 2. 968/POSTEL/88. ieee heise ibioeaiosen PCM Cable 2. Foam Skin Polyethylene Insulated Jelly Filled Aluminium Sereened, Polyethylene Sheathed Application JellyFilled, waterprotective telephone cable forlocal network 2. Foam Skin Polyethylene Insulated Untitl Aluminium Screened and Polyethylene Sheathed (Dry Cable/Non Jelly Filled) Application Telephone connecting cable forlocal networks. Polyethylene Insulated Aluminium Internal Screened, Jelly Filled Aluminium Screened Polyethylene Sheathed Specification Size: STE O10) rl) EID. ($110620-82) {0052 0.4m Tp-Bl(Pel) E20: 100%220.8mm Indoor Cable Application Digital Junction/Transmision networks PVC Insulated and PVC Sheathed Specification Size STEL-K-011 R-W2- S110709-83 100 «2x 0.6mm Indoor Cable PVC Insulated Application Instalation telephone cable for indooruse Aluminium Screnned and PVC Sheathed Specification Size STEL-K-017 R-ViPe) V2- (s0710-83) 100x2<0.6mm. Application Instalationielephonecablefor indooruse VE VOKSEL KABEL Type and Description Aerial Cable Polyethylene Insulated, Aluminium Screened Polyethylene Sheathed, Galvanized Steel Wire Bearer Specification Size Application STEL-K-001 ee ‘Overhead selfsupporting x 250.5mm athens (51100611 -82) eee on theoutskitsofthecoreana 120%20.8mm Inresidential areas U-E(Pe}S10- 420x2x1.0mm iption _-dellyFilled Armoured Cable 2.Foam Skin Polyethylene Type and Description "pe yeth iene Insulated JellyFilled, Insulated Jelly Filled Aluminium Aluminium Screened Tape, Screened tape, Steel Tape Steel Tape Armoured, Armoured, Polyethylene Sheathed Polyethylene Sheathed Specification Size Application 1, STEL-K-007 Tee. Jelly Filled, Woter protective (5110617-82) Spats telephone cable forlocal networks. Telemeo. Jo0n250 8mm TEbeifenje100 Teton e100 2. S 69/POSTEL/BS Udos2s0 6m Tet eame00- ates VOKSEL KABEL ‘Type and Description Indoor Cable Copper Conductor PVC Insulated and PVC Sheathed Specification Size Application STEL-K-002 RVV1x2x0.5mm Insfollotiontelephone se (si10612-82) cablefor Indooruse Type and Description Burial Cable Copper Conductor and Polyethylene Insulated Specification Size Application STEL-K-003 T-E}x2x0.6mm Service drop wire for (S110613-82) burried Installation Type and Description Drop Wire Copper Conductor Polyethylene Insulated and Steel Wire Bearer Specification Size Application STEL-K-004 U-ES1x2x0.6mm Service drop wire for (si1061.4-82) ‘overhead installation Type and Description Jumper Wire Copper Conductor PVC insulated Specification Size Application STEL-K-006 R-V1420.6mnen Multi purpose wire foruse on (S1100616-82). MDF, cross connecting rack and otherapplications VOKSEL KABEL ‘Type and Description Type and Description Heavy Thermoplastic Flexible Cable NYYHY (rd) Specification Size SPIN 42-6-3 2;:3;475x(1.5 ~50) mm? 50% (1.5 — 6) mm? Low Voltage Underground Cable Application Indoorand Outdoor, especiallyforhigh mobile opplionces NYFGbY, NYAFGbY, NAYRGBY, NYRGDY, NYBY, NAYBY Specification Size SPLN 43-2 2) 3; 4x(1.5 ~300) mm? SNI04-2700 5 x(1.5~50) mm? SPLN 43-8 Control Cable CVV, CCV, CVVS Specification Size JIS ©3401 2~5x(1.5-~25) men? (ERNE 650 x(1,5~6) mm Low Voltage Power Cable NA2XY, N2XY Specification Size SPLN43-6 (10 ~$00) mm? Application Urderasound, Indoor Quidoorand duct Installation whenever higher mechanical stress, ardhighorrensie leed donna soliton ond operation, ponerdsiibution, powergeneraton pion’, swichboars Application Controlcircuitof 600V orless Application Underground andduct installation cable where there isnosustain mechanicaldamoge, Power distribution, Power Generating “plants, Switchboard VOKSEL KABEL Type and Description ‘Type and Description Termoplastic Indoor Cable NYA, NYAF (flexible type) Specification Size Application SPUN 42-1 0.5~400mm? Dry room for permanent SuTOI eo inalaten,nconduior SPLN 42-3 distibclionboord’) SNI04-3236 wiring purpose Non-Metalic Sheathed Indoor Cable NYM Specification Size Application SPUN 42-2 2;3;4;5x(1.5~3.5)mm? _Indoorinstallation purposeson, SNi04-2699 inand underplasterinsialltion, even in moist rooms Low Voltage Power and Control Cable NYY/NAYY Specification Size Application SPLN 43-1 1x(1.5~500) mm? Underefound padldtek SNIO4-2701 2x(1.5~150} mm? wirethare snosustin 3;4x{1.5~300) mm? mechanical damoge, Powerdistribution, ents 0) Power generating plants, Swe Beords Medium - Heavy Thermoplastic Flexible Cable NYMHY (rd) Specification Size Application SPIN42-6-2 2;3:4;5x(0.75~2.5) mm* Underground and duct SNIO4-3234 instalation cable where thereisnosustain mechanical damage, Powerdisiibution, Power generating plants, Sitcheoards VOKSEL KABEL L.V. Bundled Conductors (NFA2X-T) Specification Size Application Phase, SPIN42=10 253412595) no? Self-Supporing overhead Pubiligh distribution for Rural 1:24(16)mme ‘orSuburban Consumers Noutral,, 1x£25~70) mm? Type and Description Secondary and Service Drop Cable (Copper and Aluminium Conductors) INF2X, NFA2X Specification Size Application SPIN42 10 254 4(6--25) mm? Laying along between distnbution|ine box und Consumer's House (Meter Boord) Type and Description ‘Overhead Multiplex Cable Quadruplex, Triplex and Duplex Specification Size Application ASTM 3AWG Connected between the ICEA-NEMA 6ANG powerline secondary ‘andthe service entrance cable onthe ‘Gonsumer'sbuilding Type and Description M.V. Overhead Single Core XLPE, Insulated Aluminium Conductors ABAC-S Specification Size Application HEC, ICEA-NEMA 35-240mm? Self-supporting SPINA -10 Overhead Distribution VOKSEL KABEL Type and Description Bare Copper Conductors BCC-1/2H, BCC-H Specification Size Application SPLN41-4,41-5 10 ~500 mm? Overhead Power Distribution IEC 228 ‘ond Transmission IISE3105 earthing Purpose - ie ype and Description a atuminium Conductors (AAC) AllAluminium Alloy Conductors (AAAC) Hard Drawn Aluminium, Conductor HAL Specification Size Application SPLN4]-6, 41-8 16 ~1000mm? Overhead Distribution JISC3109 1EC207, 208 ‘Type and Description Aluminium Conductors Steel Rainforced (ACSR) Aluminium-Clad Steel Cone, Thermal Resistant Aluminium Alloy (TACSR/AS) Specification Size Application SPLN41-7 16/25 ~550/70 mm? Overhead Distribution and JFPCA242 Transmission 1EC209 JISC3109 ‘Type and Description Galvanized Steel Wire (GSW) Specification Size Application IISG3537 35~95 mm? Overhead and buried 85183 ground wires IEC 888 a Ve VOKSEL KABEL Type and Description Three Cores Cable Cu orAl Conductor, XLPE Insulated, Copper Tape or Wires Screened and PE/PVC Sheathed ‘Type : N2XSEY, N2XSE2Y MA2XSEY,NA2XSE2Y Specification Size Rated Voltage Application SPIN43-5-4 3x(85 300) mm? 3.6/6 (7.2)kV lie SEM y 4 inderground an 1EC 605022 pto Dederocon Type and Description 18/30 (Um 36) kV Three Cores Cable CuorAl Conductor XLPE Insulated, Copper Tape or Wires Screened, Double Steel Tapes Armoured and PE/PVCSheathed ‘Type: N2XSEYBY, N2XSEYB2Y NA2XSEYBY, NA2XSEYB2Y Specification Size Rated Voltage Application SPIN43.5-4 3x(85--300)mm? 3.6/6 (7,2)KV Indoors, Outdoors 1EC60502-2 pte Undergroundons 18/30 (Um 36) kV Three Cores Cable CuorAl Conductor XLPE Insulated, Copper Tape or Wires Screened, Flat Steel Wire or Steel Wire & Steel Tape Armoured and PE/PVCSheathed ‘Type: N2XSEYFGbY NA2XSEYFGbY N2XSEYRGbY NA2XSEYRGbY Specification Size Rated Voltage Application SPIN43-5-4 3x(35--300)mm? «3.6/6 (7.2) Indoors, Outdoors upto Underatoundond 1e/aoUmaa i Cablerack Ry siza Katia Roeser ay PT VOKSEL ELECTRIC Tbk. manufacturer of POWER CABLE, TELECOMMUNICATION CABLE, and RECTANGULAR WIRE Telp. (021) 633 2208, Fox Safety & Quality

You might also like