Professional Documents
Culture Documents
Metric MagnaDrive Product Brochure Compressed PDF
Metric MagnaDrive Product Brochure Compressed PDF
BENEFITS
TECH SPECIAL
PRODUCT PAGE OF EVERY APPLICATIONS
SPECS FEATURES
PRODUCT
• Easy installation
• Virtually no • Simple design
maintenance and construction
Up to
• Up to 98% • 20+ years of Centrifugal
55 kW efficient maintenance free Pumps,
9 • Saves up to 70% operation Fans &
Up to of energy costs Blowers
• Meets ANSI B73
3000 rpm* and API 610
• No fluids, oils or
VORTEX™ chemicals Standards
• Constructed
from corrosive
resistant materials,
coatings • Adjustable Air
and durable Gap spacers
electroplating
2-2500 kW • Tolerant of
• Reliable in misalignment
demanding
13 Up to and dirty • Substantial
3000 rpm* environments; Energy Savings
on variable Ideal for High
indoors or out Inertia Systems:
torque pump and
FGC™ • No physical
connection
fan applications
• Conveyor Belts,
FIXED GAP COUPLING between motor Bucket Elevators
and load and Other
• Designed to • Dual magnet Bulk Handling
withstand air rotors that auto- Equipment
temperatures from matically move • Pumps
-40° C to 65° C further reducing
16-625 kW torque at motor • Compressors
• Cushioned motor startup • Air Pre-heaters
17 Up to
start reducing
• Air Gap increases • Fans and
system mechanical
3000 rpm* stresses during start and Blowers
operation
MGD™ • “Slips through”
temporary
providing
additional shock
• Chippers and
Shredders
MAGNAGUARD overload conditions load cushioning • Pulpers and
DELAY COUPLING Re-Pulpers
• Cushions shock-
loadings • Crushers and
• Increases bearing • Preset peak Hammermills
and seal life torque • Many More
disconnects
30-625 kW • Tolerant of motor from load
misalignment during load
21 Up to • Allows for thermal seizures or jams
expansion • Protects
3000 rpm*
• No EMI to affect valuable system
MGTL™ electronics components
TORQUE-LIMITING • Vortex, FGC, MGD from damage
COUPLING & MGTL are suitable
for both constant
and variable torque • Variable speed
applications. control
(ASD is suitable
15-2500 for variable torque • Completely
applications only) disengaged Centrifugal
kW motor start-up
• Ideal for tight Pumps,
25 space constraints • Lowest total cost Fans &
Up to of ownership Blowers
• Rapid return on
3000 rpm*
ASD™ investment
• Low total cost
• Substantial
energy savings
ADJUSTABLE of ownership
SPEED DRIVES
TECHNICAL
DATA 31 See Technical Data Section for detailed product specs
REVOLUTIONARY
POWER TRANSFER
MagnaDrive replaces the physical connection
between a motor and a load with a gap of air.
The interaction between permanent magnets
and non-ferrous conductors smoothly transmits
torque across the Air Gap from motor to load
and sets the load spinning. The smaller the gap,
the greater the torque. This Air Gap is the
cornerstone of MagnaDrive’s technology.
FIELD NOTE
MagnaDrive is the
world leader in
permanent magnet
torque transfer.
4
TECHNOLOGY
THE DISCONNECTED CONNECTION
In the construction of MagnaDrive couplings Two hubs (4) are connected to the motor and load
(VTX, FGC, MGD, MGTL) and adjustable speed shafts with a keyless, compression style locking device
drives (ASD), non-ferrous metal conductor rotors (2) called a shrink disc (excluding VTX), offering an extremely
are attached to the motor, while rotors populated balanced, durable connection. In addition to all of the
with rare earth magnets (1) are attached to the load. components above, the Adjustable Speed Drive from
These two components never touch, creating the MagnaDrive also includes an actuator mechanism (5)
Air Gap (3). The magnetic flux created between to automatically adjust the Air Gap spacing between
the magnet rotor and the conductor rotors generates the conductor rotor and the magnet rotor, allowing
torque, and transmits power safely and efficiently variable torque transfer, which results in precise,
to the load. automated speed control on centrifugal applications.
1 1
1
4 4 4 4
2 2
3 3 3
NO physical
Motor connection
Directly coupled, causing vibration transfer and
& Load misalignment problems, as well as energy inefficiency Torque is
Connection transferred across
the Air Gap
Life Of INCREASED
Bearings, Decreased equipment life due to vibration
equipment life
Seals & and misalignment issues (often severe)
NO vibration
Other transfer
Equipment
Tolerant of
Requires
VFDs misalignment
extensive laser
require
alignment
extensive Low infrastructure
Requires
Installation extensive laser Extra labor,
infrastructure
SIMPLE
& Special alignment of install time and
Eddy Current mechanical
motor and load oil level set-up
Requirements equipment
Drives are installation
heavy & bulky,
Oil disposal &
requiring extra No grease points
contamination
infrastructure on Vortex, FGC,
issues
MGD, or MGTL
Multiple
failure points Very high
Very high Harmonics
maintenance Efficient torque
maintenance & electronic
Very high transfer
system
maintenance Expensive spare
Expensive interference
parts Simple to operate
spare parts
Expensive & maintain
Operation & spare parts Uses hazardous
Environmental
Maintenance Continuous
realignment
materials
contamination &
Reduced
disposal issues
Cavitation, maintenance
necessary
vibration & Environmental
No mechanical
flashing contamination NO harmonics
No overload overload
& disposal
protection protection
No overload issues Rapid restart
protection
VFDs have
dramatic
98% EFFICIENT
efficiency
Low efficiency losses with
Energy Up to 70%
Loss of due to misalignment,
is wasted energy savings
System due to
efficiency misalignment, and from filters,
is common and frictional transformers,
Efficiency restricted
from extra losses between cooling systems
No energy losses
& Energy flow &
additional
drag on impeller & rotor, & other cooling
for ancillary
equipment
Savings load on
equipment & and between equipment
misalignment the oil &
the motor Fine-tuned Air Gap
housing walls Eddy Current
for desired process
Drives need extra
performance
power to energize
the electromagnet
6
TECHNOLOGY
REAL WORLD BENEFITS
MINIMIZED MAINTENANCE UNMATCHED RELIABILITY A LIFETIME OF ENERGY SAVINGS
Studies show that over 80% of Unlike traditional full-contact MagnaDrive saves energy.
all rotary equipment failures are couplings, MagnaDrive’s magnet Our couplings and adjustable
related to vibration. MagnaDrive’s rotor and conductor rotor are speed drives are approximately
patented Air Gap Technology never in contact with each other. 98% efficient with no additional
tolerates significantly more That means no grease points, energy loss from ancillary
misalignment than traditional no connection to wear out equipment. The Air Gap eliminates
couplings and eliminates and a significantly longer life friction and provides cushioned
vibration transfer between shafts. for bearings, seals and other starts that reduce in-rush current
equipment. Steadfast in conditions demand, saving energy where it
In today’s modern work ranging from -40° C to 65° C, is used the most—for the entire
environments, Electromagnetic MagnaDrive’s patented technology lifetime of your product.
Interference (EMI) can be a big is constructed from corrosive
source of frustration. MagnaDrive resistant materials, coatings, and Oversized equipment? The ASD
couplings actually emit less durable electroplating allowing is your top-of-the-line choice.
EMI than the associated motor, them to be installed indoors or MagnaDrive technology can be
protecting your critical equipment outdoors. You can count on a custom-tailored to maximize
from electrical damage. Costly twenty-plus-year operating life efficiency and meet your exact
repairs no longer stand between and dependability the whole performance demands. Couplings
you and your bottom line. way through. can be fine-tuned whenever
you wish to provide impeccable
process control.
energy saving
a product’s lifetime, compared to
traditional couplings.
• Easy installation • Air Gap in the coupling • Increases bearing and seal life
eliminates the mechanical
• Virtually no maintenance connection between the motor • Tolerant of misalignment
and load reducing the wear and
• Up to 98% efficient • Allows for thermal expansion
tear on equipment
• Saves up to 70% of energy costs • No EMI to affect electronics
• Designed to withstand air
• No fluids, oils or chemicals temperatures from -40°C • Suitable for both constant and
to 65°C variable torque applications
• Constructed from corrosive
resistant materials, coatings, • Cushioned motor start reducing • Ideal for tight space
and durable electroplating system mechanical stresses constraints
• Reliable in demanding and dirty • “Slips through” temporary • Rapid return on investment
environments; indoors or out overload conditions
• Low total cost of ownership
• Eliminates vibration from • Cushions shock-loadings
misalignment
HVAC
costs and cut your
IRRIGATION
energy usage by
MANUFACTURING up to 70%?
MARITIME
MILITARY
Switch to a system that is
proven to protect your critical
MINING
equipment. The revolution is
OIL & GAS ready. The time to innovate is
POWER GENERATION now. Call MagnaDrive today
PULP & PAPER
at +1 (425) 463-4700 for a
complete system evaluation,
WATER
including a personal site
WASTEWATER visit and projected energy
MANY MORE savings based on your current
equipment set-up.
8
VORTEX
Up to 55 kW
FLUX ADJUSTABLE
FIELD AIR GAP
TORQUE
RARE EARTH
MAGNETS RELATIVE
+ MOTION
NON-FERROUS VTX-03
CONDUCTOR
APPLICATIONS
Vortex from MagnaDrive is
MAGNADRIVE’S DISCONNECTED
TORQUE-TRANSFER TECHNOLOGY ideal for centrifugal HVAC
applications up to 55 kW:
• Heating Pumps, Fans and Blowers
• Air Conditioning Pumps, Fans and Blowers
• Ventilation Pumps, Fans and Blowers
Check out a
video of our
technology TECH-SPECS
in motion.
See Technical Data on page 33
10
VORTEX
SUCCESS FROM
THE FIELD / HVAC
“…Replacing the flexible couplings with MagnaDrive Vortex not
only resulted in significant savings in the avoided maintenance
costs but also saved us energy.” - HVAC Contractor
SITUATION SAVINGS
Due to severe vibration Before and after electrical system tests showed immediate reduced
and misalignment problems, motor amperage and temperature upon installation. Total average
the customer was replacing power usage decreased by 20%. Infrared scans showed the temperature
flexible couplings on their dropped by approximately 2°C, bringing the temperature out of critical
3 kW, 1500 rpm Hot Glycol range. In addition, sound levels decreased by approximately 30%.
Return Pump Systems
3 to 4 times per year.
In addition, the couplings
were experiencing critical
Annual Savings Per Coupling,
thermal growth issues and In Energy: 20%
produced an above average
amount of noise.
SUCCESS
SOLUTION Even without taking into account the significant savings from reduced
Vortex™ from MagnaDrive™ downtime and minimized maintenance, MagnaDrive couplings in this
application paid for themselves in less than 9 months.
12
FIXED GAP
COUPLING ™
(FGC) 2 - 2500 kW
your systems. Ready to save energy too? • Ideal for High Inertia Systems
• 2 - 2500 kW
Select the FGC E-Max™ with a greater • Up to 3000 rpm Operation
degree of slip to intentionally slow the • Adjustable Air Gap Spacers for
Fine-Tuned Torque
load speed–typical on variable torque
• Customizable to Fit Virtually Any
centrifugal pumps and fans-or select Space Requirement
an FGC with minimal slip for constant • Tolerates Misalignment
• Up to 30% Energy Savings on Variable
torque applications such as conveyors Torque Pump and Fan Applications
and crushers.
APPLICATIONS
• Conveyor Belts, Bucket Elevators and
Other Bulk Handling Equipment
• Pumps
• Compressors
• Air Pre-heaters
• Fans and Blowers
• Chippers and Shredders
• Pulpers and Re-Pulpers
FGC 29.0S • Crushers and Hammermills
• Mixers
FINE-TUNED FOR YOU • Many More
14
FGC
INTRODUCING E-Max™,
YOUR CONSERVATION SOLUTION
The newest member of the FGC coupling
family, E-Max offers all of the benefits
of the FGC, but also reduces energy
consumption on oversized fan and pump
systems by up to 30%.
• Easily Replaces Your Existing Coupling
• Perfect for Oversized Pumps and Fans
• Reduces System Vibration, Increasing Seal and Bearing Life
• Misalignment Tolerant
• Saves up to 30% in Energy Cost
• Eligible for Power Company Energy Conservation Credits
Determine if E-Max
is Right for You:
You want to reduce energy consumption
Available Now
Contact MagnaDrive
or your distributor
today for an energy
savings evaluation.
Ordering Information +1 (425) 463-4700 | magnadrive.com 15
SUCCESS FROM
THE FIELD / Maritime
SITUATION SAVINGS
When a ship is at sea the This maritime operator demonstrated that the FGC is capable of
structure of the ship flexes accepting up to 6mm of misalignment between the motor and
with the rolling sea. As a load shafts, proving it a robust and reliable alternative to traditional
result, systems that were couplings. As a direct result, maintenance has been reduced by
perfectly lined up while 76% per year, per pump — from 22 engineering maintenance days,
the ship was docked shift, to an average of 7 days. Extensive greasing is no longer a factor in
causing misalignment and operation, producing no hazardous waste.
increased wear on rotating
equipment. Sailors were
wasting an average of 22 days
per year per pump repairing Annual Savings Per Coupling,
and replacing mechanical
seals, couplings, and bearings
In Labor: 76%
because of coupling alignment
difficulties. In addition, the
greased couplings that were SUCCESS
being used required quarterly In maintenance savings alone, FGC couplings paid for themselves in less
maintenance that produced as than 6 months. The operator estimates its minimum savings from the
much as 1.5 kg of hazardous use of MagnaDrive couplings to be US $6.3 Million per year.
waste each year per pump.
SOLUTION
FGC™ from MagnaDrive™
16
MAGNAGUARD
DELAY ™ (MGD)
16 - 625 kW
more money available for your • Conveyor Belts, Bucket Elevators &
other Bulk Handling Equipment
bottom line. • Pumps
• Compressors
• Air Pre-heaters
• Fans and Blowers
• Chippers and Shredders
• Pulpers and Re-Pulpers
• Crushers and Hammermills
• Mixers
• Many More
MGD 14/50
TECH-SPECS
See Technical Data on Page 33
18
MGD
SUCCESS FROM
THE FIELD / Power Generation
SITUATION SAVINGS
Minnesota Power was Minnesota Power readings showed a vibration reduction of more than
experiencing severe vibration 80%. Vibration problems on their air pre-heaters have been completely
problems on their air pre- eliminated, drastically reducing the need for maintenance and repairs.
heaters. In an effort to correct
this problem, a preventive
maintenance procedure was
implemented, requiring all
couplings to be re-greased
Annual Savings Per Coupling,
during every outage. Each In Non-Energy Operation
re-greasing would tie up three
maintenance technicians for
Costs: 84%
three days. Worse yet, the
reduction in vibration levels
that was accomplished by the
SUCCESS
re-greasing would only last a
Even without taking into account the significant savings from reduced
few weeks before the vibration
downtime due to lower vibration levels, MGD couplings paid for
would return.
themselves in less than 4 months.
SOLUTION
MGD™ from MagnaDrive™
20 * As noted on Wikipedia.com
MAGNAGUARD
TORQUE
LIMITING™
(MGTL) 30 - 625 kW
APPLICATIONS
• Conveyor Belts, Bucket Elevators &
other Bulk Handling Equipment
• Pumps
• Compressors
• Air Pre-heaters
MGTL 22/500
• Fans and Blowers
22
MGTL
SUCCESS FROM
THE FIELD / Material Handling
SITUATION SAVINGS
Because of difficulty aligning After installation of the MGTL from MagnaDrive, vibration readings
and balancing fluid hydraulic showed over a 75% reduction overall. Precision alignment is no
couplings on a conveyor drive longer necessary, maintenance is drastically reduced, and the risk
system, the City of San Antonio of environmental contamination from hydraulic fluid is eliminated.
was experiencing major
misalignment issues. Excessive
vibration in all directions caused
accelerated wear and tear Annual Savings Per Coupling,
on the system, requiring the
City’s personnel to perform In Non-Energy Operation &
frequent maintenance. This Maintenance Costs: 84%
added the additional concern of
contaminating the environment
with hydraulic fluid every time
maintenance was performed.
SUCCESS
Even without taking into account the significant savings from reduced
SOLUTION
downtime due to lower vibration levels, and reduced energy consumption,
MGTL™ from MagnaDrive™
MGTL couplings paid for themselves in less than 4 months.
24
ADJUSTABLE
SPEED DRIVE™
(ASD)
15 - 2500 kW
INSTRUMENTATION
MagnaDrive supplies machine
monitoring instrumentation
upon request:
Shown Above: Top view of ASD 22.5
• Temperature Sensors • Position Indicators
rpm on Rigid Pedestal with Actuator
• Speed Sensors • And More
The Actuator positions
the ASD to give precise,
TECH-SPECS
repeatable process control
using your control system See Technical Data on Page 35
input signal.
* Testing by the U.S. Department of Energy
demonstrated that MagnaDrive’s products reduce
energy usage by up to 70% over the course of a
product’s lifetime, compared to traditional couplings
26
ASD
COOLING METHODS
Choose an air or water cooled
ASD. Air cooling is best for
applications 310 kW and lower,
while water cooling is often
recommended when your
application exceeds 375 kW,
or your motor uses a low rpm.
AIR COOLED
• Uses the Movement of Air
Over Spinning Conductors
to Dissipate Heat
• Up to 375 kW
• Motor Speed up to 3000 rpm
• Selection Based on kW and
Rpm of Specific Application
• Custom Features Available
AIR COOLED
APPLICATIONS RIGID PEDESTAL VERTICAL KIT OPTION
MOUNT OPTION
Ideal for Medium to
• For Pumps with Small • Vertical Pump Applications
High Electric Voltage Diameter/Long Shafts • Thrust Pot Available with
Motor Applications: • Split-Case Pumps Optional Non-Reversing
• Cooling Tower Fans Clutch
• Centrifugal Pumps
• Ideal for Vertical Turbine
• Centrifugal Fans & Blowers Pumps
• Variable Torque Equipment
• Centrifuges
• Many More
WATER COOLED
APPLICATIONS
28
ASD
SUCCESS FROM
THE FIELD / HVAC
SITUATION SAVINGS
The water supply at the Grand Hyatt Following ASD installation, water pressure complaints plummeted to
Hotel in Seattle, WA is provided near zero. Every room now receives smooth and consistent target
by three pumps that operate water pressure and supply, whether the hotel is at partial capacity or
sequentially in response to demand completely full—without the stepped response often seen in a multiple
from guest rooms. Hotel occupancy valve system. The Grand Hyatt Hotel is now realizing significant
varies dramatically. During high energy savings and vibration reductions greater than 70%.
occupancy levels, management
found that water pressure on
upper floors was an issue, marring
their attempt at moving from #2 Annual Savings Per Coupling,
to #1 ranking in overall customer
satisfaction, across all Hyatt Hotels. In Non-Energy Operation
System misalignment and excess
energy use were also issues.
Costs: 52%
SOLUTION
SUCCESS
Air Cooled ASD™ from MagnaDrive™
Not including the benefits of reduced maintenance and higher
customer satisfaction, ASDs from MagnaDrive paid for themselves
in 6 months.
Directly coupled
MOTOR • Creates vibration transfer and NO physical connection
& LOAD misalignment problems
• Torque is transmitted across an Air Gap
CONNECTION • Energy spent flexing an elastomeric
• Friction-free patented technology
disc or spring is energy that is not
going toward your bottom line
30
TECHNICAL
DATA
31
Fixed Gap Coupling™ (FGC) Tech-Specs
MAGNET SIDE
CONDUCTOR SIDE ASSEMBLY COUPLING
ASSEMBLY
COUPLING PEAK
DRIVER LOAD ANGULAR
COUPLING INTERNAL TORQUE MAX
Ø LENGTH WEIGHT SHAFT WEIGHT SHAFT END DBSE* MISALIGNMENT
OAL*** RADIAL (AT MIN. RPM
END TO CG* TO CG* CAPACITY
CLEARANCE** AIR-GAP)
16.5S 483 100 49.9 42 24.9 0.5 89 178 0.87 6 1011 3,000
18.5S 533 100 66.7 37 34.5 1 127 203 0.77 6 1361 3,000
20.5S 584 100 78.5 35 34.5 1 127 165 0.87 6 1574 3,000
22.5S 635 100 91.2 39 45.8 1 127 241 0.8 6 1979 3,000
24.5S 686 100 101.6 34 48.5 1 127 203 0.73 6 2431 1,500
26.5S 737 100 136.1 34 72.6 1 127 203 0.81 6 2589 1,500
28.5S 787 100 140.2 34 68.0 1 127 203 0.75 6 3070 1,500
10.5D 330 138 36.3 57 18.1 2 127 229 1.36 6 603 3,000
12.5D 381 138 47.6 68 23.6 2 140 229 1.15 6 933 3,000
14.5D 432 138 63.5 64 27.2 2 152 229 0.99 6 1426 3,000
16.5D 483 138 72.6 64 40.8 2 152 229 0.87 6 2022 3,000
18.5D 533 138 84.8 59 49.0 2 152 241 0.77 6 2722 3,000
20.5D 584 145 101.6 68 55.8 2 152 267 0.87 6 3148 3,000
22.5D 635 145 123.8 58 67.1 1 152 279 0.8 6 3958 1,500
24.5D 686 145 131.5 58 72.6 1 152 279 0.73 6 4861 1,500
26.5D 737 151 145.1 57 86.2 1 152 279 0.81 6 5179 1,500
28.5D 787 151 176.9 60 108.9 1 152 279 0.75 6 6141 3,000
17.0S 527 162 97.1 64 41.7 2 178 264 0.84 6 1622 3,000
19.0S 578 162 122.9 65 57.2 3 203 259 0.75 6 2280 3,000
21.0S 629 162 142.0 65 77.1 3 203 259 0.85 6 2664 3,000
25.0S 730 162 194.1 81 116.1 3 203 338 0.72 10 4821 3,000
29.0S 832 162 242.7 77 134.7 2 203 328 0.74 10 6526 3,000
33.0S 933 162 305.7 68 182.8 1 203 302 0.65 10 9255 1,500
37.0S 1035 162 397.3 62 265.8 2 203 356 0.58 10 12458 1,500
21.0D 629 318 226.8 127 113.4 5 305 508 0.85 6 5328 3,000
25.0D 730 343 290.3 133 136.1 5 305 508 0.72 10 9641 3,000
29.0D 832 343 392.4 151 256.3 4 324 508 0.74 10 13051 3,000
33.0D 933 343 462.7 152 340.2 6 356 533 0.65 10 18509 1,500
37.0D 1035 343 589.7 152 408.2 6 356 559 0.58 10 24916 1,500
These dimensions may vary per application. | *at min. shaft engagement | **For Parallel Shaft MAL | *** Close Coupled (Standard Hubs)
32
Vortex™ (VTX) Tech-Specs
MAGNET SIDE
CONDUCTOR SIDE ASSEMBLY COUPLING
ASSEMBLY
COUPLING PEAK
DRIVER LOAD ANGULAR
COUPLING INTERNAL TORQUE MAX
Ø LENGTH WEIGHT SHAFT END WEIGHT SHAFT END DBSE* MISALIGNMENT
OAL*** RADIAL (AT MIN. RPM
TO CG* TO CG* CAPACITY
CLEARANCE** AIR-GAP)
VTX-03 165 14 2.50 25.4 2.81 12.7 50.8 104.14 1.5 N/A 27.9 3000
VTX-07 235 75 9.53 40.64 4.99 17.78 88.9 155.70 1.5 3.175 78.6 3000
VTX-11 334 81 20.87 43.18 9.53 19.05 88.9 170.18 1.5 3.175 272.5 3000
12/20 298 158 16.8 61 17.7 65 174 257 1.46 5 141 3,000
14/30 368 158 24.9 69 24.0 71 174 257 1.75 8 253 3,000
14/40 368 158 24.9 69 26.3 73 174 257 1.17 8 354 3,000
14/50 368 158 24.9 69 27.2 73 174 257 1.17 8 404 3,000
16/60 419 158 32.2 73 33.6 76 174 257 0.99 5 495 3,000
16/75 419 158 32.2 73 35.4 77 174 257 0.99 5 618 3,000
16/100 416 180 35.8 84 44.0 96 224 305 0.99 5 743 3,000
16/125 416 180 35.8 84 46.7 98 224 305 0.99 5 992 3,000
16/150 416 180 35.8 84 49.4 99 224 305 0.99 5 1,243 3,000
16/200 416 180 35.8 84 52.2 100 224 305 0.99 5 1,491 3,000
18/250 470 180 45.8 88 59.9 94 214 297 0.87 5 2,079 3,000
18/300 470 180 45.8 88 62.6 95 214 297 0.87 5 2,384 3,000
20/350 562 184 79.4 90 93.0 88 219 325 0.76 3 2,836 3,000
20/400 562 184 79.4 90 95.7 89 219 325 0.76 3 3,186 3,000
22/450 613 184 92.1 93 105.2 90 219 325 0.7 3 3,570 3,000
22/500 613 184 92.1 93 108.0 91 219 325 0.7 3 3,977 3,000
22/600 613 184 92.1 93 110.7 91 219 325 0.7 3 4,373 3,000
24/700 706 207 135.6 104 178.3 103 258 396 0.58 6 7,638 3,000
24/1000 706 207 135.6 104 190.1 104 258 396 0.58 6 9,830 3,000
These dimensions may vary per application. | *at min. shaft engagement | **For Parallel Shaft MAL | *** Close Coupled (Standard Hubs)
FIELD NOTE
MagnaDrive has invested
over US $30 million
developing its technology.
Ordering Information +1 (425) 463-4700 | magnadrive.com 33
MagnaGuard Torque Limiting™ (MGTL) Tech-Specs
MAGNET SIDE
CONDUCTOR SIDE ASSEMBLY COUPLING
ASSEMBLY
COUPLING PEAK
DRIVER ANGULAR
DISTANCE COUPLING INTERNAL TORQUE MAX
Ø WIDTH WEIGHT SHAFT END WEIGHT DBSE* MISALIGNMENT
TO CG* OAL*** RADIAL (AT MIN. RPM
TO CG* CAPACITY
CLEARANCE** AIR-GAP)
14/40 368 199 25.4 86 26.8 90 216 297 1.17 8 354 3,000
14/50 368 199 25.4 86 27.7 90 216 297 1.17 8 404 3,000
16/60 419 199 32.7 90 34.0 94 216 297 0.99 5 495 3,000
16/75 419 199 32.7 90 35.8 95 216 297 0.99 5 618 3,000
16/100 416 234 36.7 105 44.9 118 278 359 0.99 5 743 3,000
16/125 416 234 36.7 105 47.6 119 278 359 0.99 5 992 3,000
16/150 416 234 36.7 105 50.3 121 278 359 0.99 5 1,243 3,000
16/200 416 234 36.7 105 53.1 122 278 359 0.99 5 1,491 3,000
18/250 470 234 46.3 110 61.2 118 268 349 0.87 5 2,079 3,000
18/300 470 234 46.3 110 64.0 119 268 349 0.87 5 2,384 3,000
20/350 562 239 81.6 111 98.9 111 273 378 0.76 3 2,836 3,000
20/400 562 239 81.6 111 101.6 112 273 378 0.76 3 3,186 3,000
22/450 613 239 93.9 115 111.1 114 273 378 0.7 3 3,570 3,000
22/500 613 239 93.9 115 113.9 114 273 378 0.7 3 3,977 3,000
22/600 613 239 93.9 115 116.6 115 273 378 0.7 3 4,373 3,000
24/700 706 273 137.0 128 187.8 133 324 463 0.58 6 7,638 3,000
24/1000 706 273 137.0 128 199.6 134 324 463 0.58 6 9,830 3,000
These dimensions may vary per application. | *at min. shaft engagement | **For Parallel Shaft MAL | *** Close Coupled (Standard Hubs)
FIELD NOTE
Our state-of-the-art
R&D Center and
manufacturing facility
is operated in
Woodinville, WA USA.
34
Adjustable Speed Drive™ (ASD) Tech-Specs
Air Cooled
CONDUCTOR SIDE ASSEMBLY MAGNET SIDE ASSEMBLY COUPLING
PEAK TORQUE
DISTANCE ASD MAX LINEAR
DBSE Ø WIDTH WEIGHT WEIGHT DISTANCE TO CG LINEAR PER RPM ARM LENGTH
TO CG RPM FORCE
TORQUE OF SLIP
20.5 367 610 231 103 60 103 193 1058 16.0 3000 203 82
22.5 424 626 260 148 73 148 228 1383 29.8 1500 254 159
24.5 470 727 269 231 61 231 236 1681 54.9 1500 279 227
26.5 470 727 269 237 61 237 239 2034 64.8 1500 279 227
20.5/22.5 368 626 235 104 63 104 193 1058 16.0 3000 203 82
22.5/24.5 424 727 260 151 77 151 222 1383 29.8 1500 254 159
24.5/28.5 470 778 269 231 67 231 236 1681 54.9 1500 279 227
26.5/28.4 470 778 269 237 67 237 239 2034 64.8 1500 279 227
MAGNADRIVE.COM
GLOBAL
DISTRIBUTION
AND SERVICE
©2015 MagnaDrive Corporation™. MagnaDrive™, Vortex™, FGC™, MGD™, MGTL™ and ASD™ are trademarks of MagnaDrive Corporation.
All other logos contained within belong to their respective entities and are not affiliated or in partnership with MagnaDrive Corporation.
*ISN®, ISNetworld®, and RAVS® are registered trademarks of ISN Software Corporation.