TABLE I
INDUCTION MACHINE PARAMETERS
V. EXPERIMENTAL RESULTS
Both controlled-speed and ungoverned-speed IG-based
systems previously described were implemented, employing
a three-phase 1/2-hp induction machine with four poles, and
rated voltage of 220 V in delta connection. Moreover, the PWM
inverter switching frequency was 5 kHz, uF , and
mH, while is rated to produce satisfactory dynamic
behavior during both steady-state and transient conditions.
Fig. 10. Line current from the IG including (a) C (I ), (b) PWM-inverter
line current (I ), and (c) induction motor line current (I ), during the motor
disconnection. Fig. 11. (a) Single-phase line terminal voltage. (b) Current sent to the utility.
(c) Frequency spectrum of the current sent to utility.