Single Mode Optical Fiber Cable
for Aerial or Duct Application
Non-Metallic Type
(SM 2-12 Fibers)
Page 1 of 6
、Cable
1、 Cross-section
Loose Tube
Optical Fiber
Filling Gel
FRP Tape
PE flame retardant
2-12AB
2. Cable Specification
2.2 The color of marking is white, but if the re-printing is necessary, the yellow color marking shall be
printed newly on a different position.
2.3 Each cable ends are sealed with heat shrinkable end caps to prevent water ingress.
Page 2 of 6
2.4 Fiber color code
No. 1 2 3 4 5 6
Color Blue Orange Green Brown Gray White
No. 7 8 9 10 11 12
Color Red Black Yellow Violet Pink Aqua
2.5 Loose tube (LT) & filler rod (FR) color code
Fiber Element no.
number 1 2 3 4 5 6
2 LT
4 LT
6 LT
8 LT
12 LT
2 1 1.0 6.0 41
4 1 1.0 6.0 41
6 1 1.0 6.0 41
8 1 1.0 6.0 41
12 1 1.0 6.0 41
mm mm mm
3.0 0.40 0.4*11.7
* The nominal sheath thickness may have a tolerance with ±0.2mm.
* The nominal diameter may have a tolerance with ±0.4mm.
o o
Operating temperature range :-20 C to +70 C
o o
Storage / Transport temperature range :-20 C to +70 C
o o
Installation temperature range :-20 C to +50 C
Page 4 of 6
4.3 Main mechanical & environmental performance test
- Points of impact: 5
-Times of per point: 5
Impact Resistance - Loss change ≤ 0.1 dB @1550 nm
3 - Impact energy:4.5 N.m
IEC 794-1-E4 - No fiber break and no sheath damage.
- Radius of hammer head: 15mm
- Impact rate: 2 sec/cycle
- Length: 1 m
- Load: 150 N
Torsion - Loss change ≤ 0.1 dB @1550 nm
5 - Twist rate: 1 min/cycle
IEC 794-1-E7 - No fiber break and no sheath damage.
- Twist angle: ±180°
- No. of cycle: 10
- Temperature step:
- Loss change ≤ 0.05 dB/km@1550 nm
o o o o
Temperature Cycling Test +20 C→-20 C→+70 C →+20 C
6
IEC 794-1-F1 - Time per each step: 12 hrs - No fiber break and no sheath damage.
- Number of cycle: 2
- Sample length: 30 cm
Compound Flow
7 - Temp: 70°C ± 2°C - No compound flow
IEC 794-1-E14
- Time: 24 hours
- On line test
8 Sheath High Voltage Test -No sheath breakdown
- 9t KV (t-sheath thickness)
Page 5 of 6
5.1.5 At least 1m of inner end of cable should be reserved for testing.
- Roll-direction arrow;
- Cable outer end position indicating arrow;
- Drum length;
- Other customer information such as contract no., project no., and delivery destination. (if needed)
- Quality certificate;
- Test report.
SPEC. END