You are on page 1of 4
5687 TUBES TWIN TRIODE 5687 ET-TIOWSB. FOR GENERAL-PURPOSE AMPLIFIER APPLICATIONS MEDIUM-MU HIGH PERVEANCE 9-PIN MINIATURE SEPARATE CATHODES DESCRIPTION AND RATING ‘The 5687 is a miniature, medium-mu twin triode for use in general-purpose amplifier applications. The tube is characterized by high perveance and high emission capabilities. Except for the common heater connection, each section is electrically independent. GENERAL ELECTRICAL Cathode—Coated Unipotential Series Parallel Heater Voltage, AC or DC. 126410% 69410% Volis Heater Current... 0.45 09 Amperes Direct Interalactrode Capacitances' Grid to Plate, Each Section... 40 unt Input, Each Section..... Output, Section 1 Output, Section 2.....--..++ Heater to Cathode, Each Section Grid to Grid, approxima! Plate to Plate, approximate * Without external shield. wut wat auf ook ut anf MECHANICAL Mounting Position—Any Envelope—T-6%4, Cless Bate—£9-1, Small Button 9-Pin GENERAL @@ ELECTRIC Superades T-TIOIBA dete 7-55 BASING DIAGRAM EA 9H TERMINAL CONNECTIONS Pin 1—Plate (Section 2) Pin 2—Grid (Section 2) Pin 3—Cathode (Section 2) Pin 4—Heater Pin 5—Heater Pin 6—Cathode (Section 1) 7—Grid (Section 1) Pin 8—Heater Center Tap Pin 9—Plate (Section 1) PHYSICAL DIMENSIONS MAXIMUM RATINGS DESIGN-CENTER VALUES, Each Section Plate Voltage. 300 Inverse Plate Voltage....... =. 1000 Plate Dissipation, Each Plate AQ Total Plate Dissipation, Both Plates. . 75 DC Grid Current. tee 60 Heater Cathode Voltage Heater Positive with Respect to Cathode -90 Volts Heater Negative with Respect to Cathod Grid-Cirevit Resistance. Bulb Temperature at Hottest Point. 90 Volts 1.0 Megohms +2220 C Design-Center ratings are limiting values of operating and environmental conditions applicable to a bogey tube of © specified type o2 defined by its published data, and should not be exceeded under normal conditions. ‘The tube manufacturer chooses these values to provide acceptable servicecbility of the tube in average applications, taking responsibility for normal changes in operating conditions due to rated supply-voltage variation, equipment com: ponent Variations, equipment control adjustment, load variction, signal variation, environmental conditions, and variations in tube characteristics. The equipment manufacturer should design so that intially no design-center value for the intended service is exceeded with a bogey tube in equipment operating ot the stated normal supply-valtage. CHARACTERISTICS AND TYPICAL OPERATION CLASS A; AMPLIFIER, Each Section Plate Voltage. 120 180250 Volts Grid Voltage. . =2 0-7 =125 Volts Amplification Factor: 17 16 Plate Resistance, approximate, tees 1560 2000-3000 Ohms Transconductance..... cou cevttecsseseesT 600 8500 5400 Micromhos Plate Current 3628 2 jamperes Grid Voltage, approximate Ib=100 Microamperes... -14 19 Volts PLATE CURRENT 1W MILLIAUPERES 19 sol 3 10 o no55611-7000-1 100 AVERAGE PLATE CHARACTERISTICS EACH SECTION 200 300 PLATE VOLTAGE 1M VOLTS AVERAGE TRANSFER CHARACTERISTICS EACH SECTION 40 kessertoro00-2 =30 =20 10 GRID VOLTAGE IN vouTS 400 Ey = RATED VALUE 500 ocrover 8, 1989 10 60 50 0 30 20 10 ° ‘eroocn 5, 1959 PLATE CURRENT 1M MILLIAMPERES. 5687 ET-T1O18B Poge rea AVERAGE CHARACTERISTICS 281000 en seerion seo 2 oon 20 2 5000) i 3 378 : ze Baer e 2 16 4000] = 5 sa pon 3 4 1000} o dl ° 40 20 30 40 50 PLATE CURRENT 1X MILLIAMPERES essa teranacs deroste 5, 1959 ELECTRONIC COMPONENTS DIVISION GENERAL @® ELECTRIC Schenectady 5, N. Y.

You might also like