λ1= Emtsin (2θ) ¼ Static procedures are appropriate when higher mode
effects are not significant. This is generally true for short,
4EfeIcolhinf regular building. Therefore, for tall Buildings, building
Where with torsional irregularities, or non-orthogonal systems, a
dynamic procedure is required. There are two types of
hcol = Column height between centre lines of beams dynamic analysis; response spectrum analysis and linear
hinf = Height of infill panel dynamic analysis i.e. time history analysis. In this work
90
killare Earthquake time history is used for the analysis.1. Table 5 Base shear and B.M. of G+9 Model with Out Infill
Killare earthquake - Centered near the village of Killari, Wall
Latur district, Maharashtra State, Central India (18.2N;
Sr.No Storey Base Shear Time Period B.M. (KN-
76.4E) September 30, 1993, 00:03:53 local time, Ma =
6.4; Mb= 6.3; Mw= 6.1; centroid depth = 5km; moment (KN) (SEC) M)
tensor solution yields an almost pure thrust with quasi- 1 11 0.00 0.00 0.00
horizontal P axis striking N31° E.
Table.3 Comparison of Displacement given by ETABS and 2 10 168.17 0.16 504.51
Staad Pro-07 3 9 350.89 0.33 1557.19
Displacement at top floor 4 8 493.37 0.47 3037.31
5 7 600.39 0.57 4838.49
EATABS STAAD PRO 07 6 6 677.02 0.65 6869.54
7 5 728.31 0.70 9054.48
0.0055m 0.0054m 8 4 759.34 0.72 11332.5
9 3 775.17 0.74 13658
10 2 780.87 0.75 16000
III. RESULTS AND DISCUSSION 11 1 781.27 0.75 17172.5
1 Base Shear
Table. 4 Base Shear and B.M. Of G+9 Model with Infill
Wall
Sr.No Storey Base Shear Time B.M. (KN-
(KN) Period M)
1 11 0.00 (SEC)
0.00 0.00
2 10 67.92 0.065 203.77
3 9 132.45 0.13 601.11
2. Displacements
Joint displacement of the building is compared for.
Various cases Table No 3.5. Displacement comparison
between with and without infill wall in ux direction
91
Table 7 Displacement Vs Storey No. For With and Table 8 Storey Drift For With and Without Infilled Walls
Without Infill Wall in Uy Direction in Ux Direction.
Storey Drift
Earthquake Direction Uy- Joint Displacement (M)
Point Storey Without Infill With Infill % Diff
Sr.No Storey Point Without With Infill % Diff 36 11 0.000135 0.000317 0.018
Infill
49 10 0.000128 0.000324 0.0196
1
SR. 11 47 0.00555 0.0132 0.77
2 10 9 0.0052 0.0151 0.99 9 9 0.000159 0.000415 0.0256
NO
3 9 16 0.0048 0.0141 0.93 41 8 0.000182 0.000497 0.0315
4 8 30 0.0044 0.0129 0.85
41 7 0.000199 0.000562 0.0363
5 7 43 0.0039 0.0114 0.75
6 6 30 0.0033 0.0097 0.64 41 6 0.000207 0.000607 0.0400
7 5 41 0.0027 0.0079 0.52 41 5 0.000213 0.000628 0.0415
8 4 41 0.0021 0.006 0.39
43 4 0.000214 0.000622 0.0408
9 3 41 0.0015 0.0041 0.26
10 2 41 0.001 0.0024 0.14 41 3 0.000205 0.000581 0.0376
11 1 41 0.0006 0.0009 0.03 13 2 0.000219 0.000495 0.0276
IV. CONCLUSION
Due to infill walls in the High Rise Building top storey
Fig 5. Displacement Vs Storey No. For With and Without displacement is reduces. Base shear is increased. The
Infill Wall in Uy Direction presence of non-structural masonry infill walls can
modify the seismic behavior of R.C.C.Framed High Rise
92
building to large extent. Arrangement of infill wall also [3] “The effect of masonry infill's on the seismic response of a
alters the displacement and base shear the top of building four- storey reinforced concrete frame A deterministic
displacements gets reduces. In case of infill having assessment”, Journal of Engineering Structure.,168-172.
irregularities in elevation such as soft storey that is [4] Kasim Armagan Korkmaz, and Mustafa (2007)”
damage was occur at level where change in infill pattern Earthquake Assessment of RC Structures with Masonry
is occur. The effect of slenderness ratio emphasion Infill Walls. International Journal of Science &
Technology”, Volume 2, No 2, 155-164,2007.
displacement of frame. As the aspect ratio goes on
increasing the displacement, base shear and column [5] B.Srinivas and B.K.Raghu Prasad. “The Influence of
forces increases. Masonry Infill In Reinforced Concrete Multi-Story
Buildings to Near-Fault Ground Motions”, Department of
Civil Engineering, Indian Institute of Science, Bangalore
V. DISCUSSION ON RESULTS Karnataka-560012, India.
The result of the present study show that structural
infill wall have very important effect on structural [6] George C Manos, Jafar Thaumpta and Bilal Yasin (2000).
“Influence of masonry infill’s on the earthquake response
behavior under earthquake effect. On structural capacity
of multi-story reinforced concrete structures”, Journal of
under earthquake effect displacement and relative story WCEE, pages 350-357.
displacement are affected by the structural
irregularities. Regarding with the result, infill walls are [7] Bryan Stafford Smith (1967). “Methods for Predicting the
Lateral Stiffness and Strength of Multi-Storey Infilled
very important effect on structural behavior. Frames, Building and science”, Vol. 2, pages. 247-257.
1. Base Shear:
From the results it is shown that due to infill walls in [8] Diptesh Das and C.V.R. Murty (2004) “Brick masonry
infill’s in seismic design of RC frame Buildings”, Part 2
building the base shear is increased from 2.49 to 7.81%.
Behavior. Indian concrete journal, pages. 374-387.
and the difference is 4.86%
2. Displacement: [9] Fakhredin Danesh and Vahid Behrang (2004) “The
The displacements at top story of the building with influence of masonry infill walls on dynamic behavior
of concrete structures”, 13th World Conference on
infill’s wall for single strut reduce 0.77% to 0.39% . Earthquake Engineering Paper No. 1984.
3. Storey Drift:
Storey drift for infilled wall model is within [10] Mehmet Metin Kose (2008). “Parameters affecting the
fundamental period of RC buildings with infill walls,
permissible limit. Storey drift is reduced 0.0034% to Engineering Structures”, pages. 240-250.
0.018%.
Table 10.Storey Drift [11] Matjaz Dolsek and Peter Fajfar, “On seismic behavior and
mathematical modelling of infilled RC frame structures”,
Storey Drift Journal of WCEE.
Point storey Without Infill With Infill % Diff [12] Laura Liberatore, Luis D. Decanini and Domenico
Liberatore (2004). “Seismic Lateral deformation and
19
Point 11
Storey 0.000193
Without Infill 0.000227
With Infill 0.0034
% Diff energy demands in bare and infilled RC frames”, 13th
50 10 0.000185 0.000268 0.0083 World Conference on Earthquake Engineering Page no
7007.
41 9 0.00021 0.000412 0.0202
Diff
[13] Harpal Singh, D. K. Paul, V. V. Sastry (1998) “Inelastic
41 8 0.00023 0.000541 0.0311 dynamic response of reinforced concrete infilled frames,
40 7 0.000244 0.000641 0.0397 [14] Mehmet M Kose and Ozge Karslioglu (2009) “effects of
32 6 0.00025 0.000713 0.0463 infills on high-rise buildings: a case study”, pages. 123-135
76 5 0.000247 0.00076 0.0513 [15] M. Sobaih and M. M. Abdin (1988), “Seismic analysis of
infilled reinforced concrete frames, Computers and
50 4 0.000235 0.000783 0.0548 structures” Vol. 30, No. 3, pp. 457-464.
19 3 0.000223 0.000779 0.0556 [16] Smith, S. B. and Carter, C. (1969), “A method of analysis
13 2 0.000332 0.000721 0.0389 of in-filled frames Proceedings, Institution of Civil
Engineers, London”, Vol. 44, pp. 31-48.
8 1 0.000646 0.000483 0.00
[17] Konuralp Girgin and Kutlu Darılmaz, “Seismic Response
of Infilled Framed Buildings Using Pushover Analysis,
ARI The Bulletin of the Istanbul Technical University”
Volume 54,
REFERENCES
[1] Robin Davis, Praseetha Krishnan, et all, (2004) “Effect of [18] IS 456-2000” Plain and Reinforced concrete. Code of
infill stiffness on seismic performance of multi-storey RC practice”.
framed buildings in India”, 13th World Conference on [19] “Federal Emergency Management Agency” codes no 356.
Earthquake Engineering Page no 1198.
[20] IS-1893 (Part1)-2002 “Criteria for Earthquake Resistant
[2] Matjaz Dolsek, Peter Fajfar,(2008). Design Of Structures”.
93