Professional Documents
Culture Documents
2018-Oct-30
GE Healthcare
2018-Oct-30
GE Healthcare
2018-Oct-30
GE Healthcare
3
Versana PremierTM Ultrasound System
Specification sheet Rev4
2018-Oct-30
GE Healthcare
– Installation wizard
4. System Options
– Whizz
Dynamical image optimization, Auto detection, Auto measurement and Auto – CW Doppler
annotation) Auto Bladder – Anatomical M-Mode
– CrossXBeam – Curve AMM
4
Versana PremierTM Ultrasound System
Specification sheet Rev4
2018-Oct-30
GE Healthcare
5
Versana PremierTM Ultrasound System
Specification sheet Rev4
2018-Oct-30
GE Healthcare
– Frame Average
8. Display annotation – Frame Rate
– Gray Map
8.01 General user interface
– ATO On /Off
– Patient Name: First, Last (Max 28 characters displayed
– SRI-HD
per each, Up to 64 total characters per each)
– CrossXBeam
– Patient ID (Max 64 characters)
– Other ID (Max 64 characters) 8.03 Color Flow Mode
– Age, Sex and Date of Birth – Line Density
– Hospital Name (Max 23 characters displayed) – Frame Average
– Date format: 3 Types selectable – Packet Size
• MM/DD/YYYY – Color Scale: 2 types
• DD/MM/YYYY • Power
• YYYY/MM/DD • Directional PDI
– Time format: 2 types selectable – Color Velocity Range and Baseline
• 24 hours – Color Threshold Marker
• 12 hours – Color Gain
– Gestational Age from – PDI
• LMP • GA – Inversion
• EDD • BBT – Doppler Frequency
– Displayed Acoustic Output
8.04 PDI mode
• TIs: Thermal Index Soft Tissue
– Line Density
• TIc: Thermal Index Cranial (Bone)
– Frame Averaging
• TIb: Thermal Index Bone
– Packet Size
• MI: Mechanical Index
– Directional PDI
– % of Maximum Power output
– Color Velocity Range and Baseline
– Probe Name
– Color Threshold Marker
– Map Names
– PDI Gain
– Probe Orientation
– Inversion
– Depth Scale Marker
– Lateral Scale Marker 8.05 B-flow/ B-flow color Mode
– Focal Zone Markers – Gain
– Image Depth – Background
– Zoom Depth – SRI HD
– Accumulation
8.02 B-Mode – Flow Module
– Gain
– Rejection
– Dynamic Range
– Colorize
– Imaging Frequency
– Edge Enhance
– Edge Enhance
– Gray Map
6
Versana PremierTM Ultrasound System
Specification sheet Rev4
2018-Oct-30
GE Healthcare
2018-Oct-30
GE Healthcare
German, Italian, Brazilian Portuguese, Chinese – Line Density: 5/6 steps (depending on probe)
(Simplified), Swedish, Russian, Norwegian, Danish, – Line Density Zoom: 5 steps
Dutch, Finnish, – Thermal Index: TIc, TIs, TIb
– OB Report Formats including Tokyo Univ., Osaka Univ., – Image Reverse: On/Off
USA, Europe, and ASUM – Focus Number: 8 steps
– User Defined Annotations – Focus Width: 3 types
– Body Patterns – Suppression: 6 steps
– Customized Comment Home Position – Edge Enhance: 7 steps
– Rejection: 6 steps
9.02 System scanning parameters
– Steered Linear: ±12°±15˚ (probe dependent)
– Digital Agile Beamformer Architecture
– Scanning Size (FOV or Angle – depending on the probe)
– 225,792 system processing channels
– SRI-HD: Up to 6 Levels selectable
– Max. Frame Rate: 1447 F/s (depends on probes &
– CrossXBeam: Up to 7 Angles selectable
modes)
– Depth: 1– 33 cm, 0.5 or 1 cm step, Probe dependent
– Displayed Imaging Depth: 1 – 33 cm
– Minimum Depth of Field: 0 – 2 cm (Zoom) (probe 9.04 Coded Harmonic Imaging
dependent) – Coded Phase Inversion Harmonic Imaging
– Maximum Depth of Field: 0 – 33 cm (probe dependent) – Available on all Probes
– Transmission Focus: 1 – 8 Focal Points selectable (probe – Line Density: 5/6 steps (depending on probe)
and application dependent) – Line Density Zoom: 5 steps
– Quad Beamforming – Suppression: 6 steps
– Continuous Dynamic Receive Focus/Aperture – Edge Enhance: 7 steps
– Multi-Frequency/Wideband Technology – Gray Scale Map: 7 types
– Frequency Range: 1.7 to 18 MHz – Tint Map: 9 types
– 256 Shades of Gray – Gain: 0 – 90 dB, 1 dB step
– 224dB systematic Dynamic Range – Dynamic Range:
– Adjustable Dynamic Range (36 - 96dB) – 51 to 78 dB 3dB per step; 36~48/78~96 6dB per step;
– Adjustable Field of View (FOV): up to 168degree – Rejection: 6 steps
(depending on probe) – Frequency: Up to 4 steps, probe depended
– Image Reverse: Right/Left
9.05 SRI-HD
– Image Rotation of 0° 90°180° 270°
– High Definition Speckle Reduction Imaging Provides
9.03 B-Mode multiple levels of speckle reduction
– Acoustic Power Output: 0 – 100%, 2, 5, and 10 steps – Compatible with Side by Side DualView Display
– Gain: from 0 – 90 dB, 1 dB steps – Compatible with all linear, convex and sector transducers
– Adjustable Dynamic Range: 36 – 96 dB, 3 or 6 dB steps – Compatible with B-Mode, 3D/4D imaging
– Frame Averaging: 8 steps
9.06 CrossXBeam
– Gray Scale Map: 6 or 8 types probe dependent
– Provides 3, 5, 7 of spatial compounding
– B Colorization: 9 types
– Live Side by Side DualView Display
– Frequency: Up to 11 selectable (depending on probe)
– Compatible with:
8
Versana PremierTM Ultrasound System
Specification sheet Rev4
2018-Oct-30
GE Healthcare
9
Versana PremierTM Ultrasound System
Specification sheet Rev4
2018-Oct-30
GE Healthcare
10
Versana PremierTM Ultrasound System
Specification sheet Rev4
2018-Oct-30
GE Healthcare
11
Versana PremierTM Ultrasound System
Specification sheet Rev4
2018-Oct-30
GE Healthcare
12
Versana PremierTM Ultrasound System
Specification sheet Rev4
2018-Oct-30
GE Healthcare
2018-Oct-30
GE Healthcare
14
Versana PremierTM Ultrasound System
Specification sheet Rev4
2018-Oct-30
GE Healthcare
2018-Oct-30
GE Healthcare
16
Versana PremierTM Ultrasound System
Specification sheet Rev4
2018-Oct-30
GE Healthcare
2018-Oct-30
GE Healthcare
• Right Ventricle Outflow Tract Peak Velocity (RVOT • Tricuspid Valve Velocity Time Integral (TV Trace)
Vmax) • Tricuspid Valve Time to Peak (TV Acc/Dec Time)
• Right Ventricle Outflow Tract Velocity Time Integral • Tricuspid Valve Ejection Time (TV Acc/Dec Time)
(RVOTTrace) • Tricuspid Valve A-Wave Duration (TV A Dur)
• Right Ventricle Ejection Time (RV Trace) • QRS complex to end of envelope (Q-to-TV close)
• Stroke Volume by Pulmonic Flow (RVOT Planimetry, • Tricuspid Valve Pressure Half Time (TV PHT)
RVOTTrace) • Tricuspid Valve E-Peak to A-Peak Ratio (TV E/A
• Right Ventricle Stroke Volume Index by Pulmonic Velocity)
Flow (RVOT Planimetry, RVOT Trace)
12.09-4 Color Flow Mode Measurements
System
Aortic Valve
• Pulmonary Artery Peak Velocity (PV Vmax)
• Proximal Isovelocity Surface Area: Regurgitant Flow
• Pulmonary Vein Velocity Peak A (reverse) (P Vein A)
(AR Trace)
• Pulmonary Vein Peak Velocity (P Vein D, P Vein S)
• Proximal Isovelocity Surface Area: Regurgitant
• Systemic Vein Peak Velocity (PDA Diastolic, PDA
Volume Flow (AR Trace)
Systolic)
• Proximal Isovelocity Surface Area: Aliased Velocity
• Ventricular Septal Defect Peak Velocity (VSD Vmax)
(AR Vmax)
• Atrial Septal Defect (ASD Diastolic, ASD Systolic)
Mitral Valve
• Pulmonary Vein A-Wave Duration (P Vein A Dur)
• Proximal Isovelocity Surface Area: Regurgitant Flow
• IsoVolumetric Relaxation Time (IVRT)
(MR Trace)
• IsoVolumetric Contraction Time (IVCT)
• Proximal Isovelocity Surface Area: Regurgitant
• Pulmonary Vein S/D Ratio (P Vein D, P Vein S)
Volume Flow (MR Trace)
• Ventricular Septal Defect Peak Pressure Gradient
• Proximal Isovelocity Surface Area: Aliased Velocity
(VSD Vmax)
(MR Vmax)
• Pulmonic-to-Systemic Flow Ratio (Qp/Qs)
Tricuspid Valve 12.09-5 Combination Mode Measurements
• Tricuspid Regurgitant Peak Pressure Gradient (TR Aortic Valve
Vmax) • Aortic Valve Area (Ao Diam, LVOT Vmax, AV Vmax)
• Tricuspid Valve Peak Pressure Gradient (TV Vmax) • Aortic Valve Area by Continuity Equation by Peak
• Tricuspid Regurgitant Peak Velocity (TR Vmax) Velocity (Ao Diam, LVOT Vmax, AV Vmax)
• Tricuspid Valve Peak Velocity (TV Vmax) • Stroke Volume by Aortic Flow (AVA Pl ani met ry, AV
• Tricuspid Valve Velocity Peak A (TV A Velocity) Trace)
• Tricuspid Valve Velocity Peak E (TV E Velocity) • Cardiac Output by Aortic Flow (AVA Planimetry, AV
• Tricuspid Regurgitant Mean Pressure Gradient (TR Trace, HR)
Trace) • Aortic Valve Area by Continuity Equation VTI (Ao
• Tricuspid Valve Mean Pressure Gradient (TV Trace) Diam, LVOT Vmax, AV Trace)
• Tricuspid Regurgitant Mean Velocity (TR Trace) Left Ventricle
• Tricuspid Regurgitant Velocity Time Integral (TR • Cardiac Output, Teichholz/Cubic (LVIDd, LVI Ds, HR)
Trace) Mitral Valve
• Tricuspid Valve Mean Velocity (TV Trace) • Stroke Volume by Mitral Flow (MVA Planimetry, MV
18
Versana PremierTM Ultrasound System
Specification sheet Rev4
2018-Oct-30
GE Healthcare
19
Versana PremierTM Ultrasound System
Specification sheet Rev4
2018-Oct-30
GE Healthcare
2018-Oct-30
GE Healthcare
requirements as per CISPR 11 Nothing in this material should be used to diagnose or treat any disease or condition.
• IEC 60601-2-37 Medical electrical equipment—Part Readers must consult a healthcare professional.