HXO DY} USA LOIN WORIUNY purH100B Pulse Oximeter Reference Card
Sensor and cable connecting port:
H100B is one model of H100 series Pulse Oximeter. It is
intended for cor
inuous monitoring, spot-checking of functional
pulse oxygen saturation (SpO2) and pulse rate (PR).
Well connect sensor before turning on the oximeter.
NOTE:
1. Standard power supply configuration of the oximeter is 4
pieces 1.5V LR6 AA alkaline batteries. 4 pieces Ni-H
rechargeable batteries are also compatible with the
oximeter. Take out the batteries if the oximeter will be
stored for more than one month.
2. Tissue damage may be caused by incorrect operation or
prolonged measuring duration (more than 2 hours).
3. Before measuring, user should make sure Patient Type is
set correctly. Wrong mode may lead to inaccurate
measurement or serious injuries. Press Function button to
enter menu state, enter System Setup and set Patient
Type as ADU or NEO.
4. Press Function button to enter menu state. Enter Alarm
Setup and set the Alarm System to ON or OFF. Ifit is set
to OFF, the oximeter can not give alarm in emergency.
User should use this function with caution.
214
H1008 Pulse Oximeter Reference Card
Buttons and Icons Introdu
n
@ owo8t button: Press On/OMT button and hold it for 1s to tum on
the oximeter, Press it and hold it for 2s to turn off the oxims
Return to normal measuring state by pre
12 this butto
state.
BB Backlight button: Press this button to turn on or off the backlight.
BB Alarm Silence button: When the Alarm System is ON in menu
setup, press this button to pause audio alarm for few seconds (it can
be set to 30, 60, 90 or 120s by user, refer to Chapter 3.3 in User
Bup Arrow button: In the menu state, press this button to choose
different
ms, or increase values of them. Press and hold the button
to repeat the increment, Press this button during measu
if state to
enter SpO} or PR trend graph.
M down Arrow button:
button to
n the menu state, press
choose different items, or decrease values of them, Press and hold the
button to repeat the decrement, Press the bi
ton during measuring
state to enter SpO. and PR trend table
13 Function button: Press this button to enter m
|. OF use it as
Enter button. Choose one item in menu using cursor button (Up
Arrow button or Down Arrow button), and press this button to
confirm
ye setup.
(®+ Button combination: synchronously press the On/Of