You are on page 1of 4
Pru sa FLP-PV700V/U. FLP-PVSOOV/U, SLP-PV6OOV/U SLP-PVSOOV/U SLP-PVITOV/U, 5~separation distance, A Je Dc | SPDPYIZ | SuPPvxx > =e all 1 [SPOR | LP +c Ma — Hy ER Lt ° FLP-PV1000V/Y SLP-PV1200 VY SLP-PV1000 VY Fan Ginehaton TESTS el eu ard Prote Photovoltaic arrays are costly to install and demanding in terms of technology. Their service life must be measured in decades to see a return on the invested funds. Manufacturers usually provide about a twenty-year guarantee for photovoltaicsystems. ‘To provide trouble-free technology throughout service if, itis necessary to ‘atmosphericand induced overvoltage atthe design stage to implement the Protection must be provided not only atthe output side of the inverter, but also atthe photovoltaic panels. Solar photovoltaic arrays are usually installed on rooftops, oron “greenfield ‘As for the anticipated risks (pursuant to EN 62305-2), direct or near lightning strikes are considered. Overvottage or lightning strike can bring about financial loss, and for photovoltaic systems installed on rooftops where individuals could ‘be working, injury should also be considered, Photovoltaic system designs including lightning and overvoltage suppression, shall comply with the HD 603647-712 standard (Electrical installations of buildings — Solar photovoltaic PV) systems), technical specification CLC/TS 50539-12 {PO for specific application including DC Selection and application principles —SPDs connected to PV installations) and the group of EN 62305 standards (Lightning protection). ‘The core (key device) ofthe whole photovoltaic system isthe inverter so the lightning and overvoltage protection should be focused on the inverter and, it should be incorporated into the whole lightning and overvoltage protection system. Furthermore, photovoltaic units and their bearing metal structures should be integrated into the grounding design. Selection of SPDs: maximum continuous operating vollage of SPD Uy ust be higher than or equal to 1,2 time Uscoc +if a separation distance sis kept between the lightaing conductor system (LPS) and the photovoltaic panels (insulated 25) install products SLP-PVi00« (otherwise FLP-PV200) + Fdistance between inverter and PV modules is langer than 10 m, two SPDs on DC side are necessary to protect both the PV modules (one SPD in front of the PY modules) and the inverter (one SPD infront of the inverter). Otherwise tis possible to use only one SPD (generally in front ofthe inverter. +to complete the protection system an SPD must be installed on AC side of the inverter and an SPD to protect data communication lines of the inverter. All SALTEK" SPDs for PV are tested in accordance with EN 50539-11 General wiring diagram of solar photovoltaic system connection FLP-PV500 V/U FLP-PV500V/US ‘SPD type 1 - surge arrester for photovoltaic systems Replaceable varstor module, visual fault signalling allation in the direct current Surge anester is specially designed for Grcuits of solar photovoltaic systems Optional remote status signaling (9). ‘Maximum continuous operating voltage for PV application: Upy2 12 Usesc comctonof 2 @ Sindaon tinal [roa RPusee er eT SS avec ‘Nomvnal discharge current #8/20 15) 4 nt Notas cae 2019 to an Usaaisc S08 C =a Von pean =2 a saw Votan peecn i (72-3 ot oe Serta ia eave aes ¢ om Degectraetin om fone dopa teromatuet =a 40 Naieraen Deal3smm Car sch armada soumivmat 10 vast: ancet72 a 10 Sm AT fanceten eden al fa aan pada nee Tn0V/ 054A 250070) ADC Canseco ene es cine ins ess eeqenen sas aime cee RRR sa077 RPtOWs esa Beigoet-c ALCAN E-rai nfo@sabordi com sabesystersovttigamnl owe2e6n24° NO,

You might also like