Professional Documents
Culture Documents
Openlab Laboratory
DL 10116
OVERVIEW
The switch can be also used for electric machines of other manufacturers, provided they have the
same features.
MECHANICAL FEATURES
DL 10116 is realized in a fire varnished metal housing, with a clear synoptic printed through silk-
screening process.
ELECTRICAL CHARACTERISTICS
ver a20120611 1
DL 10116
OPERATING FEATURES
The terminals L1, L2 and L3 are not connected to terminals U1, U2, V1, V2, W1 and W2.
Setting the knob on position "Y" the following terminals are connected:
L1 with U1
L2 with V1
L3 with W1
Setting the knob on position "Δ " the following terminals are connected:
L1 with U1 and W2
L2 with V1 and U2
L3 with W1 and V2
ver a20120611 2
DL 10116
L1 L2 L3
DE LORENZO
0 Y
Y
U1 V1 W1
PE
W2 U2 V2
U1 U2 U5 U6
Motor with
short-circuited rotor
V1 V2 V5 V6
W1 W2 W5 W6
DE LORENZO
It is important that you first connect the ground terminal to a good ground socket.
MAINTENANCE
The module does not need special maintenance and can be easily checked.
In case of malfunctioning, FIRSTLY DISCONNECT ALL THE TERMINALS, then open the
module to gain access to the internal components.
It is enough to check that the components and the connections are in accordance with the electrical
diagram and properly working.
ver a20120611 3
© 1996 - 2013 DE LORENZO SPA - Printed in Italy - All right reserved
DE LORENZO SPA
V.le Romagna, 20 - 20089 Rozzano (MI) Italy
Tel. ++39 02 8254551 - Fax ++39 02 8255181
E-mail: info@delorenzo.it
Web sites: www.delorenzoglobal.com - www.technical-education.it -