TENAGA NASIONAL sexnan Form 1D: 1902222912/17 ENGR-DA1 Ver 2.0 ENGINEERING DEPARTMENT ‘TRANSMISSION DIVISION TENAGA NASIONAL BERHAD DOCUMENT/DRAWING TRANSMITTAL FORM DOCUMENT TO RECORD TRANSMITTAL OF REVIEWED ere DOCUMENT/DRAWING CONTRACT NO: -TNB 236/2016 PROJECT I N209 PROJECT TITLE: PMU 132133KV TG TOKONG (2X90MVA) DRAWING SUBMISSION DATE: | 22/02/2017 JOUR REFERENCE: YOUR REFERENCE: KUBPIPROMTSTK/TNB/A7/074 TRANSMITTAL RECIPIENTS SUBMITTED TO : Name and Address of | KUB Power Sdn. Bh Contractor: Level 7, Blok D, Kompleks Kelana Centre Point, Jalan 1387/19, Kelana Jaya, 47301 Petaling Jaya, Selangor Darul Ehsan Tel, No, :03-76808741 Fax. No. :03-76809741 COPED TO: Name and Address of — |/*°slone! Manager Regional Manager: e o Regional Manager (Project - North), Asset Development Department. Transmission Division, Tenaga Nasional Bethad,Aras 4& 5, Wisma TNB, Bandar Perda,No. 1, Jalan Perda Barat,14000 Bukit Mortajam, Pulau Pinang Tel, No. :04-6301020 Fax, No. :04-5374020 © This transmittal contains attachment, TENAGA NASIONAL sennan Form 1D: 1902222912/17 ENGR-DA1 Ver 2.0 STATUS OF APPROVAL hoter:{Comments and Review ; otet INote2:| aay information are as per ApprovediNo Further Comments latached List, Appendices lc: Jand drawings JAC: Approved with comments RR: Revise and Resubmit |: For information only. Review not required No Exception Noted. Approval shall be by appointed Engineer/Owner’s Engineer RC: Reviewed and Commented rrewfoocument/oRawNe | pocuwent/pRawNG | REV], 0 | a ie No, [rite No. NO. [Sot Resistivity 1.._|Method of Statement lo O}/9/|0 o|o SIGNATURES Signature Mohammad Refat b, Adi DESIGNS/DRAWINGS s-teutdeasr haacaccata ul REVIEWED BY: lEnaineer (Substation) Dae: 24.03.207 DESIGNS/DRAWINGS Ir. Zui Othman eae VERIFIED BY: Deputy Chit Engineer (Substat wfhY eputy Chief Engineer (Substation) pate, Ce PY aft > JENDORSEDIAPPROVED B RECEIVED BY: ee Ir. Razali Daman fet Chief Engineer (Substation eee [Designation Engineering Department Transmission Division Date Tenaga Nasional Berhad oars: 3f 91201 Appendix 1- Notice of compliance with SB) TENAGA NASIONAL BERHAD Employer: a ees KUBPower contractor, [be¥#! 3: Unit, Capital 3, Oasis Square, Ara Damansara, Jalan PIU 14/7, 47301 Petaling Jay, Selangor. |Sub-Contractor/ Supplier: Name: locs SON BHO [contract No: [re 236/2016 Project Title: IKERIA-KERIA 132/33KV PMU TANJUNG TOKONG (2xSOMVA), PULAU PINANG contractor's Document No Rev Date lMeTHOD oF STATEMENT ° 222.2017 Description of Documents ISOIL RESISTIVITY AND EARTHING DESIGN signed & date Signed & date (rofessionat Eng contractor's Undertaking: lWe hereby undertakes that the Design, these Documents, the execution, |& completed Works will be in accor nce with: i. the Laws of Malaysia, and ii, the Contract, as altered or modified by Variations. As |(wame: Mohd Firdaus Bin Mohtar) For, KUB Power Sdn Bhd. 9% afar fon Contract no: TNB 236/2016 Contract KERJA-KERJA PMU 132/33KV TANJUNG TOKONG (2X90MVA), PULAU PINANG Soil resisti ity measurements procedure ‘A four-terminal earth tester is required, equipped with four shor test rods and connecting leads. ‘The test leads should be checked for continuity and condition prior to use. Before carrying out any testing, checks should be made for the location of any buried cables, earth conductors or metal pipe work. These would adversely affect the accuracy of the readings taken, particularly if they are parallel to the meastirement traverse. ‘The measurements to be performed is using the Wenner method, as advocated by the IEEE Std.81-2012. Figure | shows the general measurement arrangement. ‘The four earth rods should be driven into the ground in a straight line, ata distance “a” metres apart and driven to a depth of “d” metres. Array centre foc General Manger Ege) ‘Wnsmison OMson [exw resren Figure 1: The Wenner Soil Resistivity Measurement Array The four rods should be connected to the tester, with the outer rods connected to the C-1 and C-2 terminals, and the inner rods to the P-1 and P-2 terminals. When the instrument is switched on, there will be an apparent resistance reading on the meter, which is “R” Ohms. The apparent soil resistivity (p) is then given by 2zaR Om. Ifthe value is varying significantly, this may be due to interference, high contact resistance at the test rods, a damaged test lead or the reading being at the lower limit of the instruments measuring capability. If, after investigating the above, the reading is still changing by more than 5%, record the maximum and minimum values over an interval ofa few minutes, ealeulate the average and then proceed with the rest of the measurements. For the proposed substation, the measurements traverse is shown in Figure 2 DOS Engineering Sdn Bhd 3 Contract no: TNB 236/2016 Contract title: KERJA-KERJA PMU 132/33KV TANJUNG TOKONG (2X90MVA), PULAU PINANG (and P2 leads, where C2 probeis upto 90mfrom ‘he earth tester Figure 2: Proposed measurements traverse The earth tester is located at an arbitrary location in the centre of the area to be measured. The test leads for PL, Cl, P2 and C2 are then extended diagonally from the earth tester towards the comers of the area, where the maximum distance of C1 and C2 probes from the earth tester is 90m, while for PI and P2 probes it is 30m, The choice of the directions of the current and potential traverses are made such that the maximum current probe distance of up to 90m is achieved, and also avoiding any known buried metallic objects which may be present at the proposed site, ‘The apparent resistance measurements are then taken for a range of Wenner spacings (a). These Wenner spacings, and their corresponding distances of potential (P) and current (C) probes, are shown in Table 1. ‘Table 1: Wenner spacings ~apparent resistance measurement results are written in column RI [Spacing ta] w2iP) | Sarz(c) [Ri 4 05. 45 as | 075 | 225 7 : : WER COMMENT 3 15 45 Eyrcnm as | 225 | 675 tevse ano resveot 6 3 9 sgopunowony eo |as_| 135 A ae 135_| 675 | 2025 sis, asta 18 2 27 Te monAdtao REPT BM AD'S for coer tara been) 20 sas [405 tance Don 38 386 54 Taeaaame aT 54 2 at 1 ecansreed at aceptace of Varaon fr curratorsin andlor 2 = 2 Reeve Contac fom any Contac Corpor oresporsies DCS Engineering Sdn Bhd 4 Contract no: TNB 236/2016 Contract title; KERJA-KERJA PMU 132/33KV TANJUNG TOKONG (2X90MVA), PULAU PINANG ‘The set of apparent resistance obtained can know be interpreted to form an electrical soil model for the whole substation area. However, in order to check this set of measurements against possible irregularities in the measured soil, e.g, presence of buried metallic objects, a further measurement traverse is performed at a 90" angle to the initial traverse. This additional traverse is also recommend by the IEEE Std. 81. Hence, assuming the ire2, the additional traverse is shown in Figure 3. itial traverse adopted is the one shown in Fi + ACCESS Direction of C1 ‘and PI leads, where Cl probes F) Location ofthe p10 90mfrom fs 48) earth tester atthe fezntreof the area fit tobetested surements traverse, at a 90° angle to the initial traverse, to ‘check for irregularities Software program will be used for carrying out the detailed calculations, based upon data from the above readings, to provide a “best-fit”, representative soil model for the area, consisting of A number horizontal layers having different resistivity values. The software to be used in the present work is CDEGS, developed by SES Technologies Inc., Carfida. () sorurmser comment (ees avoesuenr a 2 Te MOMANNAAD REET BN ACIS {or Gener Mange Epes) Tikeaeenan Ba 1 Beconswved acceptance of arition ‘andor Comractors im, andlor ‘lve Conn fom ay Contac btnatons or resporatiie DCS Engineoring Sin Bhd 5 Contract no: TNB 236/2016 Contract title: KERJA-KERJA PMU 132/33KV TANJUNG TOKONG (2X90MVA), PULAU PINANG Job Scope To perform soil resi List of Workers 1, Muhd Shahirad bin Reffin 2. Mohd Rofi bin Harun NIOSH-TNB Safety Passports measurements at PMU Tanjung Tokong to sunrien commen [ssa iva ese ANO ResUONIT ingopuarion ony o one 2h HAMAD RAT I AD fer General Manager Eagnesing) Itansmtsen Osco Th enoremere ant 1 Beconsreaas ocean of aranon lar ContacarsCismanlor 1 Reve ine contain ay Cetra coiators oepennives DOS Engineering Sdn Bhd Contract no: TNB 236/2016 Contract title: KERJA-KERJA PMU 132/33KV TANJUNG TOKONG (2X90MVA), PULAU PINANG. CIDB Cards List of equipment to be used 1. AVO Megger DET 2/2 earth tester 2. 300m of test leads Eno rune commer 3. B test spikes (revs anonesvomir 4. 2 hammers a oC" one’? Te MOMRMNADREFAT BN ADRS {oc Gene Manage eee) or “Wiresdonaren aaa 1 Beconsrue acceptance of aration sso Contact's Cin, sor 1 “elevetne Contos fem ay Convactu gators erepenabies, ‘DOS Engineering Sin Bhd 2 SIRIM wanes es s ee DATEOFISSUE: 4 July2016 CERTIFICATE NUMBER. : SST/SWRIO16aR8 ISSUED BY + SIRIM Stndards Technology Sdn. Bh (Company No. 290001-P) PAGE 1 OF 2 PAGES Lot 1,18 20, alan Beremban 15/2, Seksyen 5, 40200 Shah Alan, “lomnavin ATORETS Selangor Dart Ensen Moh Prine nor Tel + €2-55109066 Fax. : 03-55109077 Shrestha vi Submited ty DCS Engineering Sdn Bhd JobNo,: $A20162054 ‘nitos-2, Jalan SU 1, Date received + 29 une 2016 PersaranSerng Uk, (£000 Arpang, Selangor, Maly ‘Alt: Mr. Ir. Dr. Az Mara Almad Marican Insteumest Auto Barth Tester Mods No, : DET22 Manufecturer :— Megeee Serial, : 6110-5931050108/2626 Instrument Conon When Received: 1, Good physical contion Instrument Condition When Returned: 1. albated ad tested serviceable. No adjustment done 2. Calvaton Due Date rqustd ty cust. 3. The User should be aware that tere ar factors that may cause this instrument instrument to drift out of calibration before the specified calibration interval has expire. Environmental Condition := Average Temperature = wes rc Average Relative Humidity + 60 © 1 %RH Calibration Date: 4 July 2016 Requested Calibration Due Date : 04 July 2017 Calibration Method ‘This instrument was calibrated using the Calibration Procedure No. BSD /0401 Rev. 1.0 Calibration Standara(s) Used Instrument Type + ‘Serial No ‘Cal Due Date. : CalCenNaw ‘Traceabilig: GR 1433x, 24347 02 February2017 —- SSTISAIRI2016B/15, SST (SA) NPL, UK YEW 279301 S2FT0634 02 February2017—SSTISAMIRI20I6BVI4 SST ($A) NPL, UK ‘The standard instruments used in this calibration are traceable to either the Notional Stindards maintained a the ‘National Metrology Laboratory, SIRIM Berhad or other recognised International Standard Loboratries Cal, Sticker No, : ALOT #8 Measurement Uncertainty + Refeto caltration esl 2 ‘The uncertainty calculation was based on the ISO Guide to the expression of Uncertainty in Measurement. LAdarad Test Linits: The tes limits piven arc based on manufictures specifications ‘iff Sigson ‘The uncertainties ar fora confidence probability of approximately 95% This ceifie is issue in excordance with the conlitiens of asreditation granted bythe SAMM which bas asesced he measurement capability of the laboatory adits racesbility to recognised atonal standards and to the nits of measuremeat eased at he coresponding national stindards Inboraory. Copyright ofthis certfiateis owned bythe issuing hbortory and may nt be eprdoeed other than nfl excep with the pon writen ‘approvalof te Had ofthe suing laboctoy. TS SIRIM thane ‘is isonee as ssT c A ses DATE. OF ISSUE: 04 July 2016 CERTIFICATE NUMBER + SSTISAR/2016G/85, PAGE 2 OF 2 PAGES Instrument Auto Earth Tester Serial No. + 6110-598/050105/2626 CALIBRATION RESULTS. Punetin Applied Test Meter Measurement Coverage Ran Value Limits Display Uncertainty Factor Resistance WkQ 189 kA w WR kA 189 ka soo ka 2 Wk 1590 KM wo 1610 ko 1599 ka foot ko 2 DkO 192 kM © 1208 kA 1199 ko soo ka 2 aka 794 KO | 806 kD 798 kQ £0 ka 2 aka 396 KA to 404 KO 399 ko +00 ka 2 19 ka 1889 kA © 1912 ka 1900 k 2 oor ka 2 16 kQ 1590 KO to 1610 KQ 1.600 k 2 + 00 ka 2 12 ka 12 kA © 1208 kA 1201 ka +00 ka 2 08 KQ 07H KA 0 080 kA 0798 ka £001 ko 2 04 KD — 0386 KM W 0404 KO 0399 ka + 000 ka 2 1 2 189 A 12 2 196° 9 sol a 2 wo 2 1390 2% 1610 2 97a ol a 2 m0 2 = 1192, 1B 97a +01 9 2 0 © DA A 6 2 ma a sol a 2 0 9 36 At 44 2 0 9 = Ol a 2 9 O 188 2 © 1912 a ol a 200 9 2 6 2 155 2 1610 1601 a = 0 a 2 R Q 2 @w 1208 9 Ro a soo a 2 8 a 194 2 0 806 2 Bor a som 2 2 4 0 395 2 401 401 0 so a 2 19 a 18 9 © 12 9 190 a +001 a 2 16 2 150 9 160 9 Loo +00! 9 2 129 1192 9 © 128 9 1202 a +001 a 2 08 2 07% A 085 2 0799 a +001 a 2 04 2 03% =A © 048 oa 9 +00 a 2 Calibrated by: ‘Mohd Fir Abd Razak ‘The uncertainties ae fora confidence probability of approximately 95% ‘This exifiews is issued in eccowdance with the conditions of eccaedation granted bythe SANM whichhas assessed the measwerent capability of the Iboatery and its acebiliy to recognised ations standards and to the uit of measuremen realised st te corespoaing tational sandals Taboraary. Copyriht ofthis cect is owned by the sung boratory and may got be produced eke than in ful exept wi the rie writen spproval ofthe Head ofthe issuing laboratory

You might also like