Noise Level Calculation

Quotation Number :
Tag Number :

Units of Measure : English

Sound Level at 100-ft from the point of discharge, L : 121.6 db


English
Required distance for Sound Level calculation, r : 3.0 feet English/Metric
Sound level at 100 ft / 30 m
Distance from Point of Discharge

Sound Level at new distance

New Sound Level at Required Distance, Lr : 152.1 db

Equation from Crosby Engineering Handbook:

r Where, L, decibels (db)


Lr =L−20⋅LOG 10 ( )
100
Lr, decibels (db)
r, feet