You are on page 1of 2

Power Capacitors

Electrical Apparatus
McGraw-Edison® Type EX-7Li®
Single-Phase Internally Fused Units 230-12
McGraw-Edison Type EX-7Li® CAPACITOR
all-film internally fused capacitors APPLICATION
(Figure 1) feature the latest
Cooper Power Systems design Capacitor application requires an
innovations; extended foil, solder- evaluation of the power system to
less connections, CLEANBREAK® determine:
element fusing system and laser- ■ The kvar requirements.
cut aluminum foil. Designed,
manufactured, and tested to meet ■ The most effective location.
or exceed the requirements of all ■ Interaction with system.
applicable ANSI/IEEE and IEC
standards, their low cost per kvar ■ The necessary protection.
makes these capacitors a simple, In general, capacitors are
economical source of reactive installed:
power on electric power systems
■ At the substation, to supply the
for:
system kvar needs most effec-
■ Power factor correction. tively.
■ Voltage support. ■ At or near the load center, to
■ Loss reduction. obtain the optimum kvar supply
and voltage correction.
■ Improving power transfer Figure 1.
capability. ■ At the end of the line, to The McGraw Edison EX-7Li®
achieve maximum voltage single phase internally fused,
■ Releasing system capacity. correction. all-film capacitor
Internally fused, power capacitors ■ In series with a distribution
can be installed individually or in feeder to minimize flicker and Available capacitor unit ratings can
factory-assembled switched or provide voltage support. be obtained by contacting the
unswitched: factory.
■ In series with a transmission
■ Open style indoor and line to minimize the reactance
substation banks.
CONSTRUCTION
of the line, improving stability
and controlling voltage drop.
FEATURES
■ Metal enclosed banks.
Construction features of McGraw-
Note that Cooper Power Systems RATINGS Edison power capacitors include:
does not recommend the use of
internally fused capacitors on pole McGraw Edison capacitors are ■ CLEANBREAK® element
mounted, distribution rack applica- rated in continuous kvar, voltage, fusing system. Each element is
tions. BIL and frequency and are protected with a series
subjected to all applicable connected CLEANBREAK®
McGraw Edison exclusive all-film, ANSI/IEEE or IEC routine tests. current limiting fuse. This
extended foil/mechanically The capacitor unit rated voltage is patented fusing system incor-
connected capacitors provide: the voltage at rated frequency that porates the following features:
■ Low losses (0.15 watt/kvar). can be applied terminal-to-terminal
continuously. See the standard to ■ Polymer fuse card provides
■ Superior electrical performance which the capacitor unit is manu- isolated fuse mounting
and reliability. factured for guidance in operation which prevents potential
above rated voltage. damage to adjacent
■ Environmentally acceptable capacitor elements and
Edisol® ST Non-PCB dielectric Single-phase capacitor units are fuses.
fluid. designed to produce rated kvar at
rated voltage and frequency within ■ Fuses are individually
■ CLEANBREAK® element mounted within a polymer
fusing system. the tolerance of the applicable
standard. As the capacitor’s kvar fuse tube. The tube protects
output is proportional to the the fuse from damage due to
square of the applied voltage, adjacent element failures
proper application requires atten- and fuse operations. This
tion to the applied voltage. design also requires no

*US Patent 4,633,369


February 2000 • New 1
Printed in USA
Single-Phase Internally Fused Capacitors

TABLE 1
Bushing Characteristics and Weights

60-Hz Withstand
Approximate Net
Creepage Strike 60-Sec. 10-Sec. Weight/
BIL Distance Distance Dry Wet Bushing
(kV) (mm) (mm) (kV) (kV) (kg)
75** 264 159 35 30 1.4
95 264 159 35 30 1.4
125 461 242 60 50 2.3
125 559 242 60 50 2.3

** Same bushing is used on 75 and 95 KV BIL capacitor units.


Internally fused capacitors are designed based on a specific kvar requirement. For this reason
The overall dimensions and weights of the units are not available until the particular unit is
designed. Please contact the factory for specific unit dimensions based on your particular kvar
requirement.

paper in the fusing dielectric, ■ Stainless steel tank with light-


thereby eliminating the gray finish for resistance to Figure 2.
generation of extensive severely corrosive atmos- CLEANBREAK® fuse protection
carbon arc by-products in pheres. Tank is finished with an system
the dielectric fluid. This epoxy primer and a urethane
significantly improves the topcoat coating system. This
dielectric performance by system has been tested to the ■ Parallel-groove terminals
preventing fluid contamination ANSI C57.12.31 pole mounted accommodate copper or
and promotes proper clearing standard and the ANSI aluminum conductors from
of element fuse. C57.12.29 coastal environment No. 8 solid to No. 1 stranded.
standard. Parallel-groove connectors are
■ The CLEANBREAK® fuse supplied on all capacitors sold
operates in a current limiting ■ High stacking factor design as individual units.
mode to chop the fault utilizing aluminum foil elec-
current into the failed trodes with a laser-cut active ■ Internal discharge resistors
element. This prevents the edge. The region of the dielec- that reduce terminal voltage as
energy stored in the parallel tric exposed to the highest elec- specified per the relevant
connected elements from tric field stress is located at the ANSI/IEEE or IEC standards.
being discharged into the active edge of the electrode. ■ Stainless-steel nameplate
fault thus minimizing gassing The high stacking factor and containing required IEC or
and damage to the failed laser cut active edge shapes NEMA/IEEE data. Nameplate
element and adjacent and reduces the electric field lettering is mechanically scribed
dielectric. stress thereby significantly to ensure long lasting perfor-
■ EX® mechanical connection increasing the discharge incep- mance. Nameplate is mechani-
system. Provides solderless tion voltage (DIV). Given their cally secured to the tank
internal connections that elimi- high DIV capability, McGraw ensuring that it will remain in
nate localized heating and cold Edison capacitors are designed place throughout the life of the
solder joints. The EX crimping to have the highest safety capacitor.
system also allows 100% margin to DIV in the industry.
■ Blue non-PCB decal.
inspection during assembly ■ Light-gray, wet-process-
assuring integrity of internal porcelain bushings; glazed for
connections and maximizes high strength and durability and
operational safety. hermetically sealed to the
■ Individual closed loop capacitor capacitor tank. Single piece
cover construction provides
fluid impregnation system.
Assures superior fluid impreg- superior sealing characteristics.
nation and gas molecule evacu- ■ Stainless-steel mounting
ation resulting in low infantile brackets with industry-standard
failure rates and long lasting 397 mm. mounting centers for
electrical performance. unit interchangeability;
under-side of each bracket is
unpainted to properly establish
tank potential.

McGraw-Edison® is a registered trademark of Cooper Industries, Inc.


Edisol® is a registered trademark of Cooper Power Systems, Inc. P.O. Box 1640, Waukesha, WI 53187
©2000 Cooper Power Systems, Inc. http://www.cooperpower.com/

2
Printed on Recycled Paper

You might also like