2011 BMW X5 3.0L Eng 35d
Service Manual: SELF DIAGNOSIS ­ DIAGNOSTIC TROUBLE CODES (M57)
BMW SELF­DIAGNOSIS M57 DIESEL > DTC P21A8 (BMW DTC 4BCC): REDUCING­AGENT
PASSIVE­TANK FILL­LEVEL SENSOR, SIGNAL: SENSOR FAULT > INFORMATION SAVED IN

DDE

BMW SELF­DIAGNOSIS M57 DIESEL > DTC P21A8 (BMW DTC 4BCC): REDUCING­AGENT
PASSIVE­TANK FILL­LEVEL SENSOR, SIGNAL: SENSOR FAULT > FAULT CODE

4BCC ­ P21A8

BMW SELF­DIAGNOSIS M57 DIESEL > DTC P21A8 (BMW DTC 4BCC): REDUCING­AGENT
PASSIVE­TANK FILL­LEVEL SENSOR, SIGNAL: SENSOR FAULT > FAULT DESCRIPTION

Monitoring of both passive tank level sensors. The DTC is logged when the physical sensor signal is between 35
% and 45 %.

BMW SELF­DIAGNOSIS M57 DIESEL > DTC P21A8 (BMW DTC 4BCC): REDUCING­AGENT
PASSIVE­TANK FILL­LEVEL SENSOR, SIGNAL: SENSOR FAULT > CONDITION FOR FAULT
IDENTIFICATION

Test condition:

The test routine is executed continuously.

Voltage condition:

The test routine is executed continuously.

BMW SELF­DIAGNOSIS M57 DIESEL > DTC P21A8 (BMW DTC 4BCC): REDUCING­AGENT
PASSIVE­TANK FILL­LEVEL SENSOR, SIGNAL: SENSOR FAULT > CONDITION FOR FAULT
MEMORY ENTRY

Debounce (2000 ms)

http://www1.prodemand.com/Print/Index?content=tabs&module=true&tab=true&terms=true&ymms=false&className= 1/2
12/18/2015 Printer Friendly View

BMW SELF­DIAGNOSIS M57 DIESEL > DTC P21A8 (BMW DTC 4BCC): REDUCING­AGENT
PASSIVE­TANK FILL­LEVEL SENSOR, SIGNAL: SENSOR FAULT > ACTION IN SERVICE

1.  Check wires and plug connections.

2.  If wiring and plug connections are OK:

3.  Use diagnostic system to check sensor signal.

4.  Replace passive tank.

BMW SELF­DIAGNOSIS M57 DIESEL > DTC P21A8 (BMW DTC 4BCC): REDUCING­AGENT
PASSIVE­TANK FILL­LEVEL SENSOR, SIGNAL: SENSOR FAULT > DRIVER INFORMATION

Warning light:

MIL

BMW SELF­DIAGNOSIS M57 DIESEL > DTC P21A8 (BMW DTC 4BCC): REDUCING­AGENT
PASSIVE­TANK FILL­LEVEL SENSOR, SIGNAL: SENSOR FAULT > SERVICE INSTRUCTION

Measure the resistance levels at the fluid­level sensor between pins 1 and 2, and between pins 3 and 4. The tank
must be empty for this measurement.

Normal resistance with empty tank: 10 kOhm.

Resistance levels in excess of 12 kOhms indicate that the fluid­level sensor is defective.