Chapter 4

Longitudinally Excited CO2 Laser

Kazuyuki Uno

Additional information is available at the end of the chapter

http://dx.doi.org/10.5772/48525

1. Introduction
In the mid-infrared region (3 – 30 μm), there are only several kinds of commercial laser as
shown in Fig. 1. A CO2 laser is very important because the CO2 laser emits high output
energy and various pulse shapes at the wavelength region between 9.2 μm and 11.4 μm with
a high absorptivity in many substances. The first CO2 laser was developed by C. K. N. Patel
in 1964 and had a continuous output power of a few milliwatts (Patel, 1964). In 1968, the
pulsed CO2 laser was developed by A. E. Hill and had a few joules (Hill, 1968). Nowadays,
various types of CO2 lasers have been developed. The characteristics of CO2 laser pulses are
determined by the discharge tube structure (a longitudinal excitation scheme like Fig. 2 (a)
or a transversal excitation scheme like Fig. 2 (b)), the discharge types (DC discharge, RF
discharge, or pulsed discharge) and the oscillation system (CW oscillation, Q-switched
oscillation, or pulsed oscillation).

Figure 1. Mid-infrared commercial lasers (Photonics.com). Unit is μm.

© 2012 Uno, licensee InTech. This is an open access chapter distributed under the terms of the
Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits
unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
116 Laser Pulses – Theory, Technology, and Applications

(a)

(b)

Figure 2. Excitation system. (a) Longitudinal excitation system. (b) Transversal excitation system.

In the CW oscillation and the long pulse oscillation (a pulse width of 10 μs – 10 ms), a low
power CO2 laser (< 10W) is used as a medical laser like tooth and skin treatments. A CO2
laser emitted 20 – 100 W is used for cutting a nonmetallic substance like a film, cloth, leather,
paper, rubber, a plastic, acrylics, etc. A high power laser emitted 100 – 400 W is used for
cutting metal, glass, and ceramics. A short pulse CO2 laser that emits an output energy of a
few joules and a pulse width of about 100 ns is used for puncturing and patterning of a
nonmetallic substance, removal of surface polymer material which does not give a damage
to a metal board, and etc. Specially, a large and high output CO2 laser called “Lekko VIII”
that emitted an output energy of 10 kJ and a pulse width of 1 ns was developed in Institute
of Laser Engineering, Osaka University, Japan, 1981 (Yamanaka et al, 1981). Recently, the
CO2 laser attracts attention as a driver laser for a Laser-Produced-Plasma Sn-EUV source
(13.5 nm) and a excitation laser for a Terahertz laser (CH3F, C2H2Cl, CH3OH, D2O, and etc.,
30 – 300 μm) (Ueno et al, 2007; He et al, 2010).
Longitudinally Excited CO2 Laser 117

2. Principle of CO2 laser


The CO2 laser oscillates in the vibrational level of CO2 molecular. The CO2 laser has about
100 oscillation lines at the center of 9.6 μm and 10.6 μm between 9.2 μm and 11.4 μm. Fig. 3
shows the energy diagram of CO2 laser. Generally, the CO2 laser is pumped by glow
discharge in the low mixed gas (CO2, N2, He, and etc.) pressure. The N2 serves to improve
the output energy and the efficiency due to the energy transfer from the vibrational level of
N2 to the upper laser level of CO2. However, in the short pulse oscillation, N2 causes a laser
pulse tail because of the long lifetime of the vibrational level of N2. The He serves to make
the discharge uniform. The CO2 molecular is efficiently pumped by very low electron
temperature because the energy of the laser upper level 001 is 2349.2 cm-1 and the energy
required for excitation of CO2 molecule is about 0.28 eV. However, generally, the CO2
molecular pumped by the higher electron temperature than 0.28 eV because of an electrical
gradient to sustain the discharge. The CO2 laser oscillates at 10.6 μm band (001 – 100
transition) and 9.6 μm band (001 – 020 transition) and has about 100 oscillation lines because
of the P branch and the R branch related to the rotational level. The laser lower levels of 100
and 020 are relaxed by the collision with the CO2 molecule of ground state. The 010 level
serves as a bottleneck. But the thermal relaxation of the 010 level is accelerated by the
collision with other molecular, He atom and the laser tube wall. Then, the 010 level returns
to the ground state. Therefore, in the efficiently laser oscillation, the N2 molecular that
supplies the upper laser level of CO2 and media like He that eases the lower laser level of
CO2 are essential. However, in the low-pressure pulse-discharge at the low repetitive
operation, He may be unnecessary.

Figure 3. Energy diagram of CO2 laser.


118 Laser Pulses – Theory, Technology, and Applications

3. Longitudinal excitation scheme


In the longitudinal excitation scheme, the excitation discharge is in the direction of the laser
axis. This system was used in the early stage of development of lasers such He-Ne lasers
(633 nm), N2 lasers (337 nm) and CO2 laser (9.2 – 11.4 μm). In this system, a dielectric tube
with the small inner diameter (1 – 2 cm in CO2 lasers) and the long length (> 30 cm in CO2
laser) is used as a discharge tube. Metallic electrodes are attached to each end of the tube.
The long discharge length provides a high breakdown voltage (> 20 kV) at a low gas
pressure (< 10 kPa). Therefore, this system does not require a high gas-pressure vessel.
Moreover, this laser may oscillate at narrow spectral width because the low-pressure
operation produces the small pressure broadening. A uniform discharge can be obtained
easily because of the fast electron drift velocity (the long mean free path) of the low pressure
operation; additionally, the discharge uniformity is not affected by residual charges in the
longitudinal excitation because a discharge takes place in a discharge tube with a long
length and small inner diameter. In a RF discharge, an electronic trapping occurs. A uniform
discharge takes place because electrons vibrate by the high-frequency electric field and are
trapped between the discharge gaps. In a pulsed discharge, a uniform discharge takes place
by a diffuse streamer discharge is formed by diffusing uniformly and progressing the minute
spark discharge with which an avalanche and optical ionization are combined (Fig. 4).

Figure 4. Longitudinally pulsed discharge.


Longitudinally Excited CO2 Laser 119

Figure 5. Longitudinally pulsed discharge with strong preionization.

Therefore, the longitudinal excitation scheme does not require a pre-ionization device like
UV and X-ray source. On the other hand, when the pre-ionization is required in the high-
pressure operation (> 1 atm), the discharge tube is covered with Al foil (Fig. 5, 6) (El-Osealy
et al, 2002b; Uno et al, 2009; Uno et al, 2012a). A corona discharge occurs along the tube wall
before the main discharge to serve as pre-ionization. Therefore, nothing is put in the
discharge tube. In the longitudinal excitation scheme without pre-ionization, a gas lifetime
is long. The gas lifetime is a phenomenon in which the laser output energy decreases with
operation time in a sealed-off operation. Impurities increases with time in the discharge
tube, UV and X-ray for the pre-ionization cannot reach the center part of the discharge
space, the uniform discharge cannot take place, the localization of the discharge occurs, and
120 Laser Pulses – Theory, Technology, and Applications

Figure 6. Longitudinally pulsed discharge with simple preionization.

the laser output energy decreases. Therefore, this scheme without the pre-ionization is
suitable for the long lifetime operation. Additionally, in this scheme, the perfect hard-sealed
discharge tube without a gasket packing like a rubber O-ring is producible because the
structure of the discharge tube is simple. Therefore, this scheme is suitable for the long
lifetime gas laser. In fact, a low-output sealed-off CO2 laser has a CW oscillation or a high
repetition oscillation without a gas-flowing system and water-cooling system effectively.
Additionally, in this scheme, the beam section of the laser is circular because the discharge
tube is used a dielectric tube like a glass tube and a ceramics tube. All the optical elements
may be circular. This scheme produces laser beam with good beam quality because the
length of optical cavity is long enough to the diameter of aperture (the inner diameter of the
discharge tube). Therefore, in the longitudinal excitation scheme, a high performance laser
can be developed with a simple, portable, and low-cost device.

In the longitudinal excitation scheme, as shown in Table 1, various laser oscillation from
mid-infrared to vacuum ultraviolet has been reported. In recent years, especially, new gas
lasers, for example, a longitudinally excited CO2 laser with short laser pulse like TEA and Q-
switched CO2 laser (Uno et al, 2009), a longitudinally excited N2 laser with the same
excitation system as an excimer lamp (Uno et al, 2006), and a longitudinally excited F2 laser
at low-pressure (total pressure of 40 Torr) (El-Osealy et al, 2002b) have been developed.
Longitudinally Excited CO2 Laser 121

Figure 7. Characteristics of longitudinal excitation system.

Table 1. Longitudinally excited gas lasers.

4. Excitation system
The shape of laser pulse depends on the discharge and oscillation types. The discharge type
can be divided into the DC (direct current) discharge, the RF (radio frequency) discharge
122 Laser Pulses – Theory, Technology, and Applications

and the pulsed discharge. The oscillation type can be grouped into the CW (continuous
wave) oscillation and the pulsed oscillation including Q-switched oscillation. The DC and
RF discharge provides the CW oscillation basically and can provide the long-pulsed
oscillation (the pulse width from several μs to several ms) by switching of excitation
discharge and the short-pulsed (giant-pulsed) oscillation (the pulse width of about 100 ns)
by using Q switch. Although it is well known the pulsed discharge provides the long-pulsed
oscillation, the pulsed discharge can provide the short-pulsed oscillation (the pulse width of
about 100 ns and the pulse tail of several tens μs) like the Q-switched CO2 laser and a TEA-
CO2 laser.

4.1. DC discharge
Figure 8 shows a general longitudinally excited CO2 laser pumped by DC discharge. The
DC-CO2 laser commonly is used a high-voltage (a few tens kV) DC power supply and emits
the CW power of several tens kW. The output power can control delicately by adjustment of
DC voltage.

A discharge tube is made of a heat-resistant hard glass pipe with an inner diameter of
several mm and is the co-axial dual structure for cooling by water. Cooling improves the
efficiency and output power of the laser oscillation by decreasing the plasma temperature.
Additionally, high output power can be provided by a multi-path system folding back the
optical path in the resonator and a multi-beam system which uses multi-tubes. High power
DC-CO2 laser emitting CW power of 1 kW using 20 discharge tubes with the inner diameter
of 9 mm and the length of 195 cm has been reported (Deshmukh & Rajagopalan, 2003).

A low power CO2 laser can operate in a sealed-off mode. In a long-life sealed-off CO2 laser, a
gold catalyst is used to regenerate CO2 from the dissociation products formed during
discharge (Tripathi et al, 1994). In the sealed-off CO2 laser, the laser beam (output power and
beam quality) is stable because discharge and the distribution of particles are uniform. In a
high power CO2 laser, a gas-flowing system circulating fresh gas is used for preventing the
decrease of the oscillation efficiency by the deterioration of gas. The longitudinal excitation
system has only an axially flowing type.

Figure 8. Discharge tube with water jacket.


Longitudinally Excited CO2 Laser 123

(a)

(b)

(c)

Figure 9. RF discharge tube. (a) Longitudinal excitation (Lee et al, 2000). (b) Transverse excitation (Terai
et al, 1993). (c) Coaxial RF-CO2 laser (Bethel, 1998).
124 Laser Pulses – Theory, Technology, and Applications

4.2. RF discharge
The first CO2 laser by C. K. N. Patel used the RF discharge excitation, 27 MC/s (Patel, 1964).
In the RF discharge excitation, the medium gas is pumped by a high-frequency voltage
(typically 13.56 MHz). In this system, electrodes are able to be put on the outer wall of
discharge tube. Thus, the electrodes are not sputtered and there are little degradation of gas
and contamination of optical components. A compact high-output CO2 laser can be
developed by high discharge input-energy per unit volume. An electronic trapping provides
good pulse characteristics.

However, generally, the RF discharge excitation scheme uses the discharge tube like Fig. 9.
Fig. 9 (b) looks like the longitudinal excitation scheme, but is the transversal excitation
scheme because the direction of discharge is perpendicular to the direction of a laser axis.

In the low pressure region less than 10 kPa, the laser pumped by RF wave more than 0.1
MHz emits CW and the laser pumped by RF wave less than 10 kHz emits pulse shapes.
Generally, the pulse oscillation of RF-CO2 lasers is realized by switching of excitation
discharge and the duty ratio of ON and OFF (Nagai, 2000). Fig. 10 (a) is a example of normal
pulses by chopping the CW output. In the axial flowing system, the gas existence time in the
discharge tube is long and the rise of gas temperature is large. It is difficult to keep the peak
value of a pulse constant for a long time. Therefore, a narrow pulse shape called an
enhanced pulse like Fig. 10 (b) or a super pulse like Fig. 10 (c) takes place.

(a) (b)

(c) (d)

Figure 10. Images of RF-CO2 laser output (Nagai, 2000). (a) CW. (b) Normal pulses. (c) Enhanced
pulses. (d) Super pulses.
Longitudinally Excited CO2 Laser 125

In the slab RF-CO2 laser, commercial sealed-off CO2 lasers produces the broad output range
from CW 20 W to CW 1 kW and the high peak pulse oscillation of 2.5 kW at the pulse width
50 μs at 1 kHz (Coherent, Inc., DIAMOND E-1000). In a compact fast axial flow CO2 laser,
the output power of CW 2.1 kW has been reported (Biswas et al, 2010). Additionally, a low-
power CO2 laser pumped by AC discharge of 60 Hz whose frequency is lower than RF
discharge has also been reported (Lee et al, 2000).

4.3. Q-switch
A Q switch is a system to produce a giant pulse with a short pulse and a high peak power. A
Q value is a standard of the resonator performance and is a ratio of a loss energy to a storage
energy in the cavity. It is hard to carry out a laser oscillation when a Q value is low, and it is
easy when a Q value is high. The Q switch rapidly decreases the high resonator losses, that
is, rapidly increases the Q value.

A CW-CO2 laser using a Q switch produces a giant pulse with a pulse width from a few tens
ns to a few μs and a peak power of several kW. In a CO2 laser, the use of a mechanical
chopper, rotating mirror (Battou et al, 2008), electrooptical (CdTe) (Tian et al, 2005) or
acoustooptical modulators (Xie et al, 2010), or saturable absorber (SF6) (Soukieh et al, 1999)
has been reported.

4.4. Pulsed discharge


A CO2 laser is easily oscillated by applying a high voltage pulse of about 20 kV to a
longitudinal discharge tube filled by CO2 gas. Fig. 11 shows a longitudinally excited pulsed
CO2 laser with a general and easy excitation circuit (Chung et al, 2002; Loy & Roland, 1977).
A voltage pulse of several hundreds V is generated by a power supply and is fed to a step-
up transformer. The high-voltage pulse of about 20 kV is directly applied to the discharge
tube. The high-voltage pulse has a long rise time of about a few hundred μs because the
transformer with a large inductance is directly connected to the discharge tube. When the
applied voltage reaches the breakdown threshold, a discharge starts and the laser oscillates.
The laser output energy depends on the discharge volume and the input energy. The laser
pulse has a long width from several tens μs to several ms because the excitation circuit
produces a long and high voltage pulse and the discharge formation time is long. For
example, the discharge tube with the length of 80 cm applied the high voltage pulse of 25
kV and produced the output power of 35 W and the width of 3 ms at 60 Hz (Chung et al,
2002).

The longitudinally excited CO2 laser produces a short laser pulse like TEA-CO2 laser and Q-
switched CO2 laser by a fast discharge. Fig. 12 shows a CO2 laser with a capacitor transfer
circuit that is used for transversal excited excimer lasers and is known as a fast discharge
circuit (Miyazaki et al, 1986). A low-inductance storage capacitor Cs was charged up to DC
voltage of about 20 kV. A spark gap was switched by a trigger pulse from a trigger circuit,
and the high voltage was transferred to a buffer capacitance Cb. When the voltage reached
126 Laser Pulses – Theory, Technology, and Applications

(a)

(b)
Figure 11. Image of longitudinally excited long-pulse CO2 laser. (a) Schematic diagram. (b)
Photograph.

the breakdown threshold, a rapid main discharge took place in the discharge tube. The high-
voltage pulse of a rise time less than 100 ns is applied to the discharge tube. Additionally, a
high-voltage resistor is connected in parallel with the discharge tube. A low resistance acts
as a shunt resistance and provides a rapid discharge.
For example, in our study (Uno et al, 2009), the discharge tube was a ceramic pipe made of
alumina, with an inner diameter of 13 mm, an outer diameter of 17 mm, and a length of 45
cm. The discharge tube was covered with an Al sheet. Therefore, the laser tube had a coaxial
structure for reducing the discharge impedance. An optical cavity was formed by a ZnSe
output coupler with a reflectivity of 80% and a high-reflection mirror with a radius of
curvature of 20 m. The distance between the output coupler and the mirror (i.e., the cavity
length) was 54 cm. In the excitation circuit, the storage capacitance Cs was 5.4 nF and
charged up to DC 20 kV, and the buffer capacitance Cb was 2.8 nF. The fall time of the
discharge voltage decreased from 32.8 μs (10 MΩ) to 0.97 μs (100 Ω). In the fast discharge,
the gain increases gradually from the start of discharge. When the gain becomes enough
Longitudinally Excited CO2 Laser 127

(a)

(b)

Figure 12. Longitudinally excited short-pulse CO2 laser with capacitor-transfer circuit (Uno et al, 2009).
(a) Schematic diagram. (b) Photograph.

after several μs from the start of discharge, the laser oscillates by a gain Q switch and a spike
laser pulse is formed. At that time, the main discharge finishes mostly. Low current after the
main discharge and the energy transfer of the upper-level N2 with the long lifetime causes
the laser pulse tail of several tens μs. The pulse tail can be eliminated by eliminating the
after current or using of pure CO2 gas to eliminate the long N2 tail. Fig. 13 and 14 shows the
laser pulse in the discharge formation time of 32.8 μs and 0.97 μs, respectively, at the same
discharge tube with the inner diameter of 13 mm and the length of 45 cm and the same gas
pressure of 2.9 kPa (CO2: N2: He= 1: 1: 2) (Uno et al, 2009). Fig. 13 shows the laser pulse with
the spike pulse width of 103.3 ns, the pulse tail length of 61.9 μs, and the output energy of 50
128 Laser Pulses – Theory, Technology, and Applications

mJ by the discharge formation time of 32.8 μs. The pulse tail length was defined from the
end of the spike pulse to the end of the pulse tail. Fig. 14 shows the laser pulse with the
spike pulse width of 96.3 ns, the pulse tail length of 17.2 μs, and the output energy of 30 mJ
by the discharge formation time of 0.97 μs. These results showed the fast discharge caused
the decrease of the pulse tail.

(a) (b)

Figure 13. Laser pulse waveforms at slow discharge (discharge formation time of 32.8 μs and gas
pressure of 2.9 kPa (CO2: N2: He= 1: 1: 2)) (Uno et al, 2009). Intensity of vertical axis is normalized by
peak strength. (a) Overall waveform. (b) Magnified time scale view of spike pulse.

(a) (b)

Figure 14. Laser pulse waveforms at fast discharge (discharge formation time of 0.97 μs and gas
pressure of 2.9 kPa (CO2: N2: He= 1: 1: 2)) (Uno et al, 2009). Intensity of vertical axis is normalized by
peak strength. (a) Overall waveform. (b) Magnified time scale view of spike pulse.
Longitudinally Excited CO2 Laser 129

The capacitor-transfer circuit like Fig. 12 developed for the transversely excited excimer
laser (Miyazaki et al, 1986). The capacitor-transfer circuit has a buffer capacitance in parallel
with the laser tube. The buffer capacitance functions to increase the applied voltage due to
the storage capacitance. However, because the transverse excitation scheme has a narrow
electrode gap and a small discharge impedance, a buffer capacitance is required to sustain
the discharge. On the other hand, the longitudinal excitation scheme has a wide electrode
gap and a large discharge impedance and does not require a buffer capacitance to sustain
the discharge. Therefore, a circuit without a buffer capacitance, called a direct-drive circuit
like Fig. 15, has been developed (Uno et al, 2012a). Fig. 15 shows a longitudinally excited
CO2 laser with a direct-drive circuit (Uno et al, 2012a). A negative several hundreds V pulse
was generated by the power supply with a silicon-controlled rectifier and was fed to a

(a)

(b)

Figure 15. Longitudinally excited short-pulse CO2 laser with direct-drive circuit (Uno et al, 2012a). (a)
Schematic diagram. (b) Photograph.
130 Laser Pulses – Theory, Technology, and Applications

transformer, which had a primary capacitance. First, a negative voltage pulse was generated
and was used to charge a storage capacitor through a rectifier. Then, a positive voltage pulse
generated by the overshoot of the transformer was applied to the trigger electrode of the
spark gap through a rectifier and a small capacitor. The storage capacitor was charged, the
spark gap was switched, and the high voltage was applied to the laser tube. When the
voltage reached the breakdown threshold, a rapid discharge took place in the laser tube.
This system produces a short pulse CO2 laser with a spike pulse.
For example, in our study (Uno et al, 2012a), the laser tube was the almost same as the above
longitudinally excited CO2 laser with the capacitor-transfer circuit. A different point was a
partially preionization. Part of the discharge tube was covered with an Al sheet for a high
discharge starting voltage. In the excitation circuit, the primary capacitance Cp was 10.2 μF
and the storage capacitance was 700 pF.

(a) (b)

Figure 16. Discharge voltage and CO2 laser pulse waveforms at 3.4 kPa (mixed gas, CO2 : N2 : He = 1 : 1
: 2) (Uno et al, 2012a). Black and gray lines represent laser pulse and discharge voltage, respectively. (a)
Overall waveform. (b) Magnified time scale view of spike pulse.

Figure 17. Discharge voltage and CO2 laser pulse waveforms at 2.2 kPa (pure CO2) (Uno et al, 2012a).
Black and gray lines represent laser pulse and discharge voltage, respectively.
Longitudinally Excited CO2 Laser 131

Fig. 16 shows the discharge voltage and laser pulse waveforms at the mixed gas (CO2: N2:
He= 1: 1: 2) pressure of 3.4 kPa. The discharge starting voltage was –60.2 kV, and the fall
time of the discharge was 4.4 μs. The laser oscillation began 2.1 μs after the start of
discharge. The laser pulse had a sharp spike, like that from TEA and Q-switched CO2 lasers.
The spike pulse width was 147 ns (FWHM), and the pulse tail length was 35.5 μs. The laser
output energy was 27.8 mJ, and the energy of the spike pulse part was estimated to be 3.1
mJ. Fig. 17 shows the discharge voltage and laser pulse waveform at the pure CO2 gas
pressure of 2.2 kPa. The discharge starting voltage was –60.8 kV, and the fall time of the
discharge was 1.9 μs. Laser oscillation began 0.6 μs after the start of discharge. The laser
output energy was 0.4 mJ. The laser pulse contained a spike pulse only, and the width was
93 ns (FWHM). Pulse-tail-free oscillation was realized by the use of pure CO2 gas.
Figure 18 shows the simplest short-pulse longitudinally excited CO2 laser (Uno et al, 2012b).
This system has a laser tube, a capacitor, a resister, and a pulse power supply with a low-
voltage silicon-controlled rectifier, and a set-up transformer only. The excitation circuit does
not have a high-voltage switch; instead, the laser tube plays the role of the switch. Therefore,
this system is almost same as the above long-pulse longitudinally excited CO2 laser.
However, the step-up transformer has the fast rise time of about 3 μs. The fast transformer
produces the fast discharge which causes the short laser pulse.

(a)

(b)
Figure 18. Short-pulse longitudinally excited CO2 laser with switchless circuit (Uno et al, 2012b). (a)
Schematic diagram. (b) Photograph.
132 Laser Pulses – Theory, Technology, and Applications

For example, in our study (Uno et al, 2012b), the laser tube was the same as the above
longitudinally excited CO2 laser with the capacitor-transfer circuit (Uno et al, 2009). In the
excitation circuit, the primary capacitance Cp was 4.7 μF, the storage capacitance Cs was 700
pF, and the resistor R was 10 MΩ.

(a) (b)
Figure 19. Discharge voltage and CO2 laser pulse waveforms at 3.8 kPa (CO2: N2: He= 1: 1: 2) (Uno et
al, 2012b). Black and gray lines represent laser pulse and discharge voltage. (a) Overall waveform. (b)
Magnified time scale view of the start of discharge.

(a) (b)

Figure 20. Discharge voltage and CO2 laser pulse waveforms at 9.0 kPa (CO2: N2: He= 1: 1: 2) (Uno et al,
2012b). Black and gray lines represent laser pulse and discharge voltage, respectively. (a) Overall
waveform. (b) Magnified time scale view of the start of discharge.

The long pulse oscillation takes place at gas pressure less than 3.8 kPa (CO2: N2: He= 1: 1: 2)
and the short pulse oscillation takes place at gas pressure more than 4.2 kPa. Fig. 19 shows
the discharge voltage and laser pulse waveforms at 3.8 kPa. The discharge voltage reached -
25.8 kV at a raise time of 3.4 μs. In the low pressure, the breakdown voltage is low. The
discharge starts when the applied voltage reaches the breakdown voltage. The fall time of
Longitudinally Excited CO2 Laser 133

the main discharge was 2.8 μs. Laser oscillation took place 3.5 μs after the start of discharge.
At this time, the discharge continues. The laser pulse did not have a spike pulse and is a
conventional long pulse oscillation. The laser output energy was 10.0 mJ. The laser pulse
width was the full width at half maximum (FWHM) of 17.7 μs and the pulse length of 88.3
μs. Fig. 20 shows the discharge voltage and laser pulse waveforms at 9.0 kPa. The discharge
voltage reached -29 kV at a raise time of 3.1 μs. In the high pressure, the breakdown voltage
is high and the applied voltage reaches maximum. The fast discharge is influenced by the
impedance matching of the excitation circuit and the discharge space. The fall time of main
discharge was 2.2 μs. The laser oscillation took place 7.5 μs after the start of discharge. The
laser pulse had a spike pulse width of 218 ns and a pulse tail length of 16.7 μs. The laser
output energy was 1.7 mJ. The energy of the spike pulse part was estimated to be 0.1 mJ. It
may be necessary to improve the output energy for various supplications.

5. Application
5.1. CW and long pulse
5.1.1. Medical applications
80 wt% of soft biological tissue is water. Evaporation of water is a factor important for soft
tissue excision (Awazu, 2008). In laser irradiation, evaporation of water takes place at the
critical temperature of 101 K (Auerhammer et al, 1999). The evaporation of water causes the
soft tissue excision around the laser irradiation part. The tensile strength of soft tissue is
about 10 MPa on skin and several MPa on corneas, blood vessel, and muscle (Duck, 1990).
The laser excision of soft tissue is carried out by a high mechanical power which causes a
phase transition because 1 atm is about 0.1 MPa.

A CO2 laser is effectively absorbed in water. In 9.2 – 11.4 μm of the CO2 laser wavelength
band, the absorption coefficient is 103 cm-1 (Zarrabi & Gross, 2011). Therefore, in the CO2
laser, the penetration depth to soft biological tissue is short and about 50 μm. The CO2 laser
evaporates only surface of soft tissue. Heat influence of deeper tissue is small and the
damage to normal tissue is minimally suppressed. Edema and sharp pain after an operation
are little because the heat influence is restrictive. In the CO2 laser irradiation, shrink,
dehydration, and carbonization of surface tissue take place. They cause water evaporation
and vaporization of inner tissue. In this process, a protein denaturation layer of residual
tissue is certainly generated. The denaturation layer functions as a solidification layer for an
arrest of hemorrhage.

At present, a CO2 laser of about 3 W a pulsed CW of (10 – 1000 ms and a super pulse of 0.1 –
1 ms) is used for the skin treatment such as eliminating a mole, a wart, macule (Gotkin et al,
2009) and wrinkle the aurinasal treatment such as hay fever and allergic rhinitis (Takeno et
al, 2009), the eye treatment such as blepharochalasis and droopy eyelid (Rokhsar et al, 2008),
and the dental treatment such as section and evaporation of soft tissue, hemostasis, and
stomatitis (Zand et al, 2009). The advantages of CO2 laser surgery are alleviation of bleeding,
pain and edema, and shortening of operation and recovery time.
134 Laser Pulses – Theory, Technology, and Applications

5.1.2. Industrial applications


When laser is irradiated to a material surface, a part is reflected by the reflectance of the
material to the laser wavelength at the material surface, and the remainder is absorbed at the
material surface. Then, the temperature of the material surface increases. A part of the heat
is radiated by the heat radiation rate of the material, and the remainder conducts to inside
by the heat conductivity of the material and makes the internal temperature increase. The
surface temperature is fixed by the balance between the thermal energy lost by heat
conduction and radiation and the thermal energy given by the laser. If the surface
temperature does not reach the melting point of the material, a surface treatment takes
place. If the surface temperature reaches the melting point, the melting takes place. When
the heat input stops by movement or a stop of the laser beam, the material is cooled.
Solidification causes welding. Eliminating the molten material (e.g. gas blowing) causes
cutting. When the surface temperature exceeds the boiling point of the material by
increasing the thermal energy given by the laser beam, a hole called keyhole begins to be
formed. The laser reaches the inside of the material through the keyhole. The penetration
causes deep melting process called keyhole welding.
The laser cutting is a specialty application of CO2 lasers. In the laser cutting, a beam control
is important. In space, the beam with TEM00 mode or the beam with low order mode of axial
symmetry like TEM00 mode is required. In time, the control of the beam power (W/cm2) is
required. In the laser cutting of metals like steel, a fine cutting without heat influence, strain,
and dross is required. It is very important to optimally control heat input by control of the
peak power, the repetition rate, the duty ratio, and so on. These factors must be optimally
controlled according to the kind of material, the thickness, and the cutting speed. A metal
with a few mm of thickness can be cut by the CO2 laser with the peak power of 100 – 200 W,
the repetition rate of about 300 Hz, the cutting speed of about 30 cm/min, and the duty ratio
of about 30%. In non-metallic materials such as woods, cloth, paper, ceramics, glass, gum,
plastics, polyimide, epoxy, polycarbonate, vinyl and so on, the absorption of CO2 laser light
is very large. Most of these non-metallic materials can be processed (cutting, hole making,
marking, etc.) by a low output CW-CO2 laser emitted less than 300 W. The laser processing
is used for the cutting of automobile instrument panels and clothes, the hole making of the
material (e.g. ceramics), which the mechanical processing is difficult for, and so on.

5.2. Short pulse


5.2.1. Applications by commercial TEA-CO2 lasers
An ablation process by irradiation of a short-pulse CO2 laser is used for hole-making a
printed board, marking to a resin board, and cleaning a metal part. In the hole-making of a
printed board, improving density of trace is the purpose. Making a via-hole with a diameter
of 50 mm or less requires several tens kW of the peak power, a few μs of the pulse width
and a few kHz of repetition rate. Thus, TEA-CO2 lasers are used for the-hole making. The
laser marking stamps the model number and name of a product, the date of manufacture, a
lot number, etc. In a TEA-CO2 laser, image transfer with mask is used because the TEA-CO2
Longitudinally Excited CO2 Laser 135

laser produces high output power. CO2 lasers are used for marking to resin boards, such as
glass epoxy. In the laser cleaning, TEA-CO2 lasers are used for dirt and coat removal on
metal material. Dirt and a coat are removed by laser ablation because they tend to absorb
the CO2 laser light than metal. This process does not give the damage by heat to a surface of
metal, because the laser light is reflected when the metal material appears. The laser
cleaning does not use a medical fluid and blast material, and is a dry process.

5.2.2. Future applications


At present, drilling of hard tissue (enamel and dentine) uses an Er:YAG laser with the
wavelength of 2.94 μm that is well correspond with the absorption wavelength of water. In
2.94 μm of the Er:YAG laser wavelength, the absorption coefficient is 104 cm-1 (Zarrabi &
Gross, 2011). The laser light is focused on water and micro-explosion of water drills hard
tissue. CO2 laser can also drill hard tissue because the CO2 laser (9.2 – 11.4 μm) is well
absorbed in water. However, a long-pulsed CO2 laser which is used in the present dental
clinic causes carbonization of hard tissue. Fig. 21 (a) and (b) shows the human tooth surface
irradiated by a long-pulsed longitudinally excited CO2 laser with the pulse width of 30 μs
and the output energy of 80 mJ. The dentin which contains heat-sensitive protein was
carbonized by thermal influence because of the long-pulsed CO2 laser. On the other hand,
Fig. 21 (c) and (d) shows the human tooth surface irradiated by a short-pulsed
longitudinally excited CO2 laser with the spike pulse width of about 100 ns, the pulse tail
length of about 60 μs, and the output energy of 80 mJ (Uno et al, 2009). The short-pulsed
CO2 laser resulted in almost no carbonization not only for the enamel but also for the
dentine.

Additionally, CO2 lasers are also absorbed in the human tooth (Heya et al, 2003). The
dentine has a weak acid resistance and becomes a saprodontia easily. The dentine is
reformed to a hydroxyapatite that has a strong acid resistance by the laser with the
wavelength of 8.8 – 10.6 μm (Heya et al, 2003). CO2 lasers can change the dentine to the
hydroxyapatite because the wavelength corresponds to the wavelength of the CO2 laser.
Moreover, the dentin covers dental pulp and is porous. Exposure of the dentine causes
dentinal hypersensitivity. The irradiation of the CO2 laser melts and blocked the dentine
surface. Thus, by the CO2 laser, the medical treatment of dentinal hypersensitivity is also
possible. The longitudinally excited CO2 laser is expected as a complex dental care machine
because the laser can produce the long pulse for the soft tissue treatment and the short pulse
for the hard tissue treatment with a low-cost and portable device.

Glass marking can be effectively performed by a low-power CO2 laser because glass absorbs
infrared light well. Additionally, the glass marking is energy saving because a CO2 laser has
high electro-optical conversion efficiency. However, a long-pulsed CO2 laser produces
cracks on the surface of glass by heat influence. Fig. 22 (a) shows the glass surface irradiated
by a long-pulsed longitudinally excited CO2 laser with the pulse width of about 30 μs and
the output energy of about 45 mJ. The processing part looks white by cracking. On the other
hand, a short-pulsed CO2 laser produces crackless marking. Fig. 22 (b) shows the glass
136 Laser Pulses – Theory, Technology, and Applications

(a) (b)

(c) (d)

Figure 21. Tooth surface irradiated longitudinally excited CO2 laser (Uno et al, 2009). (a) Dentine
surface by long-pulsed CO2 laser irradiation. (b) Enamel surface by long-pulsed CO2 laser irradiation.
(c) Dentine surface by short- pulsed CO2 laser irradiation. (d) Enamel surface by short- pulsed CO2 laser
irradiation.

(a) (b)

Figure 22. Glass surface irradiated longitudinally excited CO2 laser (Uno et al, 2009). (a) Long-pulse
CO2 laser irradiation. (b) Short-pulse CO2 laser irradiation.
Longitudinally Excited CO2 Laser 137

surface irradiated by a short-pulsed longitudinally excited CO2 laser with the spike pulse
width of about 100 ns, the pulse tail length of about 60 μs and the output energy of about 45
mJ (Uno et al, 2009). The processing part is not visible with the naked eye because the part
does not have a crack. In fact, the short-pulsed CO2 laser produces stealth marking.
However, the irradiation fluence is limited by the heat influence of the pulse tail. Therefore,
the development of a short-pulsed CO2 laser without pulse tail is desired. The short-pulsed
longitudinally excited CO2 laser with a low-cost and portable device will produce a device
for product identification and traceability by marking for every process in a factory, and
management of a sample by marking in a research institution.

6. Conclusion
In this chapter, the longitudinally excited CO2 laser has been described. The excitation
system and mechanism of the CO2 laser, the feature of longitudinal excitation system and
the excitation discharge, and the application of the CO2 laser have been explained.
Especially, in the longitudinally excited CO2 laser pumped by pulse discharge, new
excitation circuits have been introduced and the relation between the discharge and the laser
pulse has been explained. The longitudinally excited CO2 laser can produce CW oscillation,
long pulse oscillation, or short pulse oscillation with a compact, simple, and low-cost device.
The development of a maintenance-free and warm-up-free device can be expected by the
simple structure. Therefore, a user-friendly CO2 laser which anyone can use easily always
anywhere will contribute to various fields.

Author details
Kazuyuki Uno
University of Yamanashi, Japan

7. References
Auerhammer, J. M., Walker, R., Meer, A. F. G. & Jean, B. (1999). Dynamic Behavior of
Photoablation Products of Corneal Tissue in the Mid-IR: A Study with FELIX. Applied
Physics B, Vol. 68, (1999), pp. 119–119.
Awazu, K. (2008). Infrared Laser for Biomedical Engineering. in Japanese, Osaka University
Press, Osaka, ISBN: 978-4-87259-160-6.
Battou, K., Ameur, K. A. & Ziane, O. (2008). Q-switch of a continuously pumped CO2 laser
with a scanning coupled-cavity Michelson mirror. Optics Communications, Vol. 281,
(2008), pp. 5234-5238.
Bethel, J. W., Baker, H. J. & Hall, D. R. (1998). A new scalable annular CO2 laser with high
specific output power. Optics Communications, Vol. 125, (1998), pp. 352–358.
Biswas, A. K., Bhagata, M. S., Rana, L. B., Verma, A. & Kukreja, L. M. (2010). Indigenous
development of a 2 kW RF-excited fast axial flow CO2 laser. PRAMANA, Vol. 75, (2010),
pp. 907-913.
138 Laser Pulses – Theory, Technology, and Applications

Burkhard, P., Gerber, T. & Luthy, W. (1981). XeF excimer laser pumped in a longitudinal
low-pressure discharge. Applied Physics Letters, Vol. 39, (1981), pp. 19–20.
Chung, H.-J., Lee, D.-H., Hong, J.-H., Joung, J.-H., Sung, Y.-M., Park S.-J. & Kim, H.-J. (2002).
A simple pulsed CO2 laser with long milliseconds pulse duration. Review of Scientific
Instruments, Vol. 73, (2002), pp. 484-485.
Cleeschinsky, D., Dammasch, D., Eichler, H. J. & Hamisch, J. (1981). XeF-LASER WITH
LONGITUDINAL DISCHARGE EXCITATION. Optics Communications, Vol. 39, (1981),
pp. 79–82.
Deshmukh, S. V. & Rajagopalan, C. (2003). High-power multibeam CO2 laser for industrial
applications. Optics & Laser Technology, Vol. 35, (2003), pp. 517-521.
Duck, F. A. (1990). Physical Properties of Tissue. Academic Press, London,ISBN: 978-
0122228001.
Eichler, H. J., Hamisch, J., Nagel, B. & Schmid, W. (1985). KrF laser with longitudinal
discharge excitation. Applied Physics Letters, Vol. 46, (1985), pp. 911–913.
El-Osealy, M. A. M., Jitsuno, T., Nakamura, K. & Horiguchi, S. (2002a). Gain characteristics
of longitudinally excited F2 lasers. Optics Communications, Vol. 205, (2002), pp. 377–384.
El-Osealy, M. A. M., Jitsuno, T., Nakamura, K., Uchida, Y. & Goto, T. (2002b). Oscillation
and gain characteristics of longitudinally excited VUV F2 laser at 40 Torr total pressure.
Optics Communications, Vol. 207, (2002), pp. 255–259.
El-Osealy, M. A., Ido, T., Nakamura, K., Jitsuno, T. & Horiguchi, S. (2001). Oscillation and
gain characteristics of high power co-axially excited N2 gas lasers. Optics
Communications, Vol. 194, (2001), pp. 191–199.
Furuhashi, H., Hiramatsu, M. & Goto, T. (1987). Longitudinal discharge XeCl excimer laser
with automatic UV preionization. Applied Physics Letters, Vol. 50, (1987), pp. 883–885.
Gotkin, R. H., Sarnoff, D. S., Cannarozzo, G., Sadick, N. S. & Armenakas, M. A. (2009).
Ablative Skin Resurfacing With a Novel Microablative CO2 Laser. Journal of Drugs in
Dermatology, Vol. 8, (2009), pp. 138–144.
He, Z., Zhang, Y., Zhang, H., Zhang, Q., Liao, J., Zhou, Y., Liu, S. & Luo, X. (2010). Study of
Optimal Cavity Parameter in Optically Pumped D2O Gas Terahertz Laser. Journal of
Infrared, Millimeter, and Terahertz Waves, Vol. 31, (2010), pp. 551-558.
Heya, M., Sano, S., Takagi, N., Fukami, Y. & Awazu, K. (2003). Wavelength and Average
Power Density Dependency of the Surface Modification of Root Dentin Using an MIR-
FEL. Lasers in Surgery and Medicine, Vol. 32, (2003), pp. 349–358.
Hill, A. E. (1968). MULTIJOULE PULSES FROM CO2 LASERS. Applied Physics Letters, Vol.
12, (1968), pp. 324-327.
Hocker, L. O. & Phi, T. B. (1976). Pressure dependence of the atomic fluorine laser transition
intensities. Applied Physics Letters, Vol. 29, (1976), pp. 493–494.
Javan, A., Bennett, Jr. W. R. & Herriott, D. R. (1961). Population Inversion and Continuous
Optical Maser Oscillation in a Gas Discharge Containing a He-Ne Mixture. Physical
Review Letters, Vol. 6, (1961), pp. 106–110.
Komatsu, K., Matsui, E., Kannari, F., & Obara, M. (1991). Low Pressure Atomic Xenon Laser
Excited by Self-Sustained Longitudinal Discharge. The Review of Laser Engineering, in
Japanese, Vol. 19, (1991), pp. 490–495.
Longitudinally Excited CO2 Laser 139

Lee, D.-H., Chung H.-J. & Kim, H.-J. (2000). Comparison of dc and ac excitation of a sealed
CO2 laser. Review of Scientific Instruments, Vol. 71, (2000), pp. 577-578.
Loy, M. M. T. & Roland, P. A. (1977). Simple longitudinally pulsed CO2 laser and its
application in single-mode operation of TEA lasers. Review of Scientific Instruments, Vol.
48, (1977), pp. 554-556.
Miyazaki, K., Hasama, T., Yamada, K., Fukatsu, T., Eura, T. & Sato, T. (1986). Efficiency of a
capacitor-transfer-type discharge excimer laser with automatic preionization. Journal of
Applied Physics, Vol. 60, (1986), pp. 2721-2728.
Nagai, H. (2000). Laser Process Technology, in Japanese, Optoronics Co. Ltd., Tokyo, ISBN:
978-4-902312-36-2.
Newman, L. A. (1978). XeF* and KrF* waveguide lasers excited by a capacitively coupled
discharge. Applied Physics Letters, Vol. 33, (1978), pp. 501–503.
Patel, C. K. N. (1964). SELECTIVE EXCITATION THROUGH VIBRATINAL ENERGY
TRANSFER AND OPTICL MASER ACTION IN N2-CO2. Physical Review Letters, Vol. 13,
(1964), pp. 617-619.
Photonics.com. http://www.photonics.com/LinearCharts/Default.aspx?ChartID=1
Rokhsar, C. K., Ciocon, D. H., Detweiler, S. & Fitzpatrick, R. E. (2008). The Short Pulse
Carbon Dioxide Laser Versus the Colorado Needle Tip with Electrocautery for Upper
and Lower Eyelid Blepharoplasty. Lasers in Surgery Medicine, Vol. 40, (2008), pp. 159–
164.
Rosa, J., J. Eichler, H. & Herweg, H. (1986). ArF laser excited in a capacitively coupled
discharge tube. Journal of Applied Physics, Vol. 54, (1986), pp. 1598–1599.
Soukieh, M., Ghani, B. A. & Hammadi, M. (1999). Mathematical modeling TE CO2 laser with
SF6 as a saturable absorber. Optics & Laser Technology, Vol. 31, (1999), pp. 601-611.
Takeno, S., Hirakawa, K., Ishino, T. & Goh, K. (2009). Surgical treatment of the inferior
turbinate for allergic rhinitis: clinical evaluation and therapeutic mechanisms of the
different techniques. Clinical & Experimental Allergy Reviews, Vol. 9, (2009), pp. 18–23.
Terai, K., Murata, T. & Tamagawa, T. (1993). Characteristics of RF Excited CO2 Lasers. The
Review of Laser Engineering, in Japanese, Vol. 21, (1993), pp. 475–484.
Tian, Z., Sun, Z. & Qu, S. (2005). Tunable pulse-width, electro-optically cavity-dumped, rf-
excited Z-fold waveguide CO2 laser. Review of Scientific Instruments, Vol. 76, (2005), 083110.
Tripathi, A. K., Gupta, N. M., Chatterjee, U. K. & Bhawalkar, D. D. (1994). Development of a
sealed-off cw CO2 laser using a supported gold catalyst. Review of Scientific Instruments,
Vol. 65, (1994), pp. 3853-3855.
Ueno, Y., Soumagne, G., Sumitani, A., Endo, A. & Higashiguchi, T. (2007). Enhancement of
extreme ultraviolet emission from a CO2 laser-produced Sn plasma using a cavity
target. Applied Physics Letters, Vol. 91, (2007), 231501.
Uno, K., Akitsu, T. & Jitsuno, T. (2012a). Longitudinally excited CO2 laser with short laser
pulse using direct-drive circuit. Journal of Engineering and Technology, Vol. 2, (2012) pp.
101-106.
Uno, K., Jitsuno, T. & Akitsu, T. (2012b). Simple short-pulse CO2 laser excited by
longitudinal discharge without high-voltage switch. Journal of Infrared, Millimeter, and
Terahertz Waves, Vol. 33, (2012), pp. 485-490.
140 Laser Pulses – Theory, Technology, and Applications

Uno, K., Nakamura, K., Goto, T. & Jitsuno, T. (2006). Longitudinally Excited N2 Laser
Pumped by Lamplike Discharge. Japanese Journal of Applied Physics, Vol. 45, (2006), pp.
1651-1653.
Uno, K., Nakamura, K., Goto, T. & Jitsuno, T. (2008). Longitudinally excited N2 lasers
without high-voltage switches. Review of Scientific Instruments, Vol. 79, (2008), 063107.
Uno, K., Nakamura, K., Goto, T. & Jitsuno, T. (2008). Red-F* Laser and VUV-F2 Emission
Pumped at Low Pressure by Longitudinal, Lamp-Like Discharge. Plasma and Fusion
Research, Vol. 3, (2008), 037.
Uno, K., Nakamura, K., Goto, T. & Jitsuno, T. (2009). Longitudinally Excited CO2 Laser with
Short Laser Pulse like TEA CO2 Laser. Journal of Infrared, Millimeter, and Terahertz Waves,
Vol. 30, (2009), pp. 1123–1130.
Xie, J., Guo, R., Li, D., Zhang, C., Yang, G. & Geng, Y. (2010). Theoreteical calculation and
experimental study of acousto-optically Q-switched CO2 laser. Optics Express, Vol. 18,
(2010), 12371.
Yamanaka, C., Nakai, S., Matoba, M., Fujita, H., Kawamura, Y., Daido, H., Inoue, M.,
Fukuyama, F. & Terai K. (1981). The LEKKO VIII CO2 gas laser system. IEEE Journal of
Quantum Electronics, Vol. 17, (1981), pp. 1678-1688.
Zand, N., Ataie-Fashtami, L., Djavid, G. E., Fateh, M., Alinaghizadeh, M.-R., Fatemi, S.-M. &
Arbabi-Kalati, F. (2009). Relieving pain in minor aphthous stomatitis by a single session
of non-thermal carbon dioxide laser irradiation. Lasers in Medical Science, Vol. 24, (2009),
pp. 515–520.
Zarrabi, A. & Gross, A. J. (2011). The Evolution of Lasers in Urology : Lasers: A Short
History and Simplified Physics. Therapeutic Advances in Urology, Vol. 3, (2011), pp. 81–
89.
Zhou, Z., Zeng, Y. & Qiu, M. (1983). XeCl excimer laser excited by longitudinal discharge.
Applied Physics Letters, Vol. 43, (1983), pp. 347–349.