Professional Documents
Culture Documents
Honeywell BW Max XT II Datasheet PDF
Honeywell BW Max XT II Datasheet PDF
CO Carbon Monoxide
O2 Oxygen
F E AT U R E S & B E N E F I T S
• Integrated sampling • Conveniently manage • Continuous visual • Simple automatic • Bright wide-angled
pump with reliable your detector with compliance with calibration procedure; visual alarm bars
diaphragm technology Fleet Manager II IntelliFlash™ compatible with
• Built-in concussion-
MicroDock II
• Best in class block • Equipped with • Compact and proof boot
automatic test and
detection with standard datalogging lightweight design
calibration station • Compatible with
semi-conductor and event logging makes it comfortable
Honeywell BW™
pressure sensor to wear • Full function self-test
• Continuous LCD Connect for real time
of sensor, battery
• Multi-language shows real-time gas • Water-resistant monitoring
status, circuit integrity
support in English, concentrations
and audible/visual
French, German,
alarms on start-up
Spanish and
Portuguese
Honeywell BW™ Max XT II Technical Specifications
TECHNICAL SPECIFICATIONS SENSOR SPECIFICATIONS
SIZE 5.1 x 2.8 x 2.0 in. / 13.1 x 7.0 x 5.2 cm STANDARD
MEASURING
WEIGHT 11.5 oz. / 328 g
GASES RANGE RESOLUTION
OPERATING TEMPERATURE -4 to 122ºF / -20 to 50ºC
HYDROGEN SULFIDE (H2S) 0 - 200 ppm 1 / 0.1 ppm
HUMIDITY 10 - 100% RH (non-condensing)
CARBON MONOXIDE (CO) 0 - 1,000 ppm 1 ppm
ALARMS AND TYPE Visual, vibrating, audible (95 dB); Low, High, TWA,
OXYGEN (O2) 0 - 30% vol. 0.1% vol.
STEL, OL (over limit), Low Battery, Pump
COMBUSTIBLE GASES (LEL) 0 - 100% LEL 1% LEL
SELF-TEST Audible/visual alarms on activation, sensors,
0-5.0% v/v 0.1% v/v
battery, pump and circuitry (continuous)
TYPICAL BATTERY LIFE 13 hours @ 32ºF / 0ºC Alarm setpoints for all sensors are user adjustable. Setpoint(s)
8 hours @ -4ºF / -20ºC are automatically displayed during instrument start-up.
Recharges in 6 hours
PUMP DRAW Sample from up to 75 ft. / 23 m OPTIONS AND ACCESSORIES
Note: Do not attempt to calibrate a Honeywell BW™ Max XT with tubing
longer than the standard calibration tubing supplied with the detector.
USER OPTIONS • Confidence beep • Force calibration when overdue MicroDock II Compatible
• Safety (sensor) lock • Sensor configuration Automatic test and calibration station
• Latching alarms • Detector identification
• Safe display mode • Low alarm acknowledge
• Calibration IR lock • Language choices (five)
• Location selection • Set custom start-up message
• Force block test • Confidence interval
• Force bump test when overdue • Datalog interval Concussion-proof boot
RATINGS EMI/RFI: Complies with EMC Directive 2004/108/EC
INGRESS PROTECTION IP66/67
CERTIFICATIONS AND h : Class I, Div. 1, Gr. A, B, C, D Honeywell BW™ Connect*
APPROVALS Real-Time Monitoring
IECEx : Ga Ex ia IIC T4
ATEX : X g II 1 G Ga Ex ia IIC T4 *Contact Honeywell Analytics for
availability
: Br Ex ia IIC T4
WARRANTY Full two year warranty including all sensors
Americas
detectgas@honeywell.com
Asia Pacific
analytics.ap@honeywell.com
Technical Services
EMEA: HAexpert@honeywell.com
US: ha.us.service@honeywell.com Datasheet_Max XT II_DS01105-07_US-EN | 04/18
AP: ha.ap.service@honeywell.com ©2018 Honeywell International Inc.